Permit #2022100276

Permit Details

Status: COED

Parcel Id: 07-11-31-7034-00060-0010
CONDITIONED SPACE: 2860 sqft
OPENED PORCH (WITH ROOF) : 348 sqft
GARAGE: 912 sqft
Total Square Footage: 4120 sqft
Block: 00060
Subdivision: 2165 - SECTION 34-EASTHAMPTON
Job Phone: 386-237-8427
Location Address: 9 EMPIRE LN
Type: DU - DUPLEX
Issue Date: 11/30/2022
NOC: RECORDED
Applicant name: JAY DARREN CURBOW
Owner: BLUE WATER PROPERTIES II LLC

Address

PO BOX 9

CISSNA PARK, IL 60924

Lot: 0010
Contracted Stated Job Value: ¤245,250.00
Job Description: Duplex
Type: CN

Contractor

BLUE WATER HOMES INC
Status Location Address State License Number Phone
ACTIVE

4881 PALM COAST PARKWAY NW UNIT 1

PALM COAST, FL 32137

CBC1258679 (Exp: 08/31/2026) 386-445-3405

Sub Contractors

JEFFREY TROY SABAKA
Status Location Address State License Number Phone Fax
ACTIVE

2191 DEERWOOD ACRES DR

ST AUGUSTINE, FL 32084

CFC1427439 (Exp: 08/31/2026) 904-838-2218 904-819-0965
BRETT CHRISTIAN GIBSON
Status Location Address State License Number Phone
ACTIVE

250 SEGOVIA RD

ST AUGUSTINE, FL 32086

CAC1818423 (Exp: 08/31/2026) 904-229-8131
JACK DOUGLAS LANIER
Status Location Address State License Number Phone Fax
ACTIVE

485 COMMERCE WAY

LONGWOOD , FL 32750

CCC058022 (Exp: 08/31/2026) (321)441-2300 (321)441-2313
WILLIAM FRANK DUDLEY JR.
Status Location Address State License Number Phone
ACTIVE

P.O. BOX 978

Bunnell, FL 32110

EC0003177 (Exp: 08/31/2026) (386)437-3068

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 02/06/2024 FINAL APPROVED BTAYLOR
Note: 1/30/2024 - PREVIOUS INSPECTION NOTES 1/23/2024 - PREVIOUS INSPECTION NOTES 1/23/24: Unit A: 1). Still no Insulation certificate posted or on site. 2). Garage ceiling is still not repaired/sealed properly. Material must be fire retardent or meet the minimum thickness to act as fireblock & be sealed along edges as required. (R302.11.1). Please also seal ceiling at low voltage line (as previously stated in item 5). 3). Previously listed item 6 is still not resolved properly. Unit B: 1). Garage ceiling is still not repaired/sealed properly. Material must be fire retardent or meet the minimum thickness to act as fireblock & be sealed along edges as required. (R302.11.1). 2). Previously listed item 6 is still not resolved properly. 1/17/2024 - PREVIOUS INSPECTION NOTES 1/17/24: Unit A: 1). Hall smoke detector needs temporary dust cover removed. (smokes tested & approved for operation only). 2). Range anti-tip device is not protecting Range from tip over as required. (possibly due to backsplash keeping range from wall). 3). No Insulation Certificate posted in attic space or on site. 4). Guest bath tub spout not sealed as required. FBC-P2705.1(3) 5). Holes in garage ceiling along with wall to ceiling seam behind AHU need to be sealed properly. (fire retardent product such as mastic or joint compound - no caulk). 6). Master bedroom smokes are too close to the peak of the vaulted ceiling per NFPA 29.11.3.1(Smoke alarms or smoke detectors mounted on a peaked ceiling shall be located within 36 in. (910 mm) horizontally of the peak, but not closer than 4 in. (100 mm) vertically to the peak). 7). Anti-siphon device at hose bibbs are missing the set screw and are not secured as required. P2902.4.3 8). AHU: Heater core installed is not identified as required. FBC-M1303.1 9). Left side: Meter Panel Main cover is missing nuts on bottom bolts. 10). Lanai outlet cover is painted shut. Could not test outlet. Unit B: 1). Hall smoke detector needs temporary dust cover removed. (smokes tested & approved for operation only). 2). Range anti-tip device is not protecting Range from tip over as required. (possibly due to backsplash keeping range from wall). 3). No Insulation Certificate posted in attic space or on site. 4). Guest bath tub spout not sealed as required. FBC-P2705.1(3) 5). Holes in garage ceiling along with wall to ceiling seam behind AHU need to be sealed properly. (fire retardent product such as mastic or joint compound - no caulk). 6). Master bedroom smokes are too close to the peak of the vaulted ceiling per NFPA 29.11.3.1(Smoke alarms or smoke detectors mounted on a peaked ceiling shall be located within 36 in. (910 mm) horizontally of the peak, but not closer than 4 in. (100 mm) vertically to the peak). 7). Anti-siphon device at hose bibbs are missing the set screw and are not secured as required. P2902.4.3 8). Garage door opener is not plugged in. Could not be safety tested or GFCI tested. 9). Garbage disposal is not plugged in. Could not be tested. 10). AHU breaker is too big. 35amp installed. (30amp required). 8/2/23: Will need attic access in Master Bedroom closet (Both Units) to view blown in insulation at Building Final Inspection. We will not be able to verify from Garage Access Panel. (walking space is too low & filled with ductwork, etc.)
BLD - BUILDING FINAL 01/30/2024 CANCELLED BY APPLICANT JWALKER
Note: 1/23/2024 - PREVIOUS INSPECTION NOTES 1/23/24: Unit A: 1). Still no Insulation certificate posted or on site. 2). Garage ceiling is still not repaired/sealed properly. Material must be fire retardent or meet the minimum thickness to act as fireblock & be sealed along edges as required. (R302.11.1). Please also seal ceiling at low voltage line (as previously stated in item 5). 3). Previously listed item 6 is still not resolved properly. Unit B: 1). Garage ceiling is still not repaired/sealed properly. Material must be fire retardent or meet the minimum thickness to act as fireblock & be sealed along edges as required. (R302.11.1). 2). Previously listed item 6 is still not resolved properly. 1/17/2024 - PREVIOUS INSPECTION NOTES 1/17/24: Unit A: 1). Hall smoke detector needs temporary dust cover removed. (smokes tested & approved for operation only). 2). Range anti-tip device is not protecting Range from tip over as required. (possibly due to backsplash keeping range from wall). 3). No Insulation Certificate posted in attic space or on site. 4). Guest bath tub spout not sealed as required. FBC-P2705.1(3) 5). Holes in garage ceiling along with wall to ceiling seam behind AHU need to be sealed properly. (fire retardent product such as mastic or joint compound - no caulk). 6). Master bedroom smokes are too close to the peak of the vaulted ceiling per NFPA 29.11.3.1(Smoke alarms or smoke detectors mounted on a peaked ceiling shall be located within 36 in. (910 mm) horizontally of the peak, but not closer than 4 in. (100 mm) vertically to the peak). 7). Anti-siphon device at hose bibbs are missing the set screw and are not secured as required. P2902.4.3 8). AHU: Heater core installed is not identified as required. FBC-M1303.1 9). Left side: Meter Panel Main cover is missing nuts on bottom bolts. 10). Lanai outlet cover is painted shut. Could not test outlet. Unit B: 1). Hall smoke detector needs temporary dust cover removed. (smokes tested & approved for operation only). 2). Range anti-tip device is not protecting Range from tip over as required. (possibly due to backsplash keeping range from wall). 3). No Insulation Certificate posted in attic space or on site. 4). Guest bath tub spout not sealed as required. FBC-P2705.1(3) 5). Holes in garage ceiling along with wall to ceiling seam behind AHU need to be sealed properly. (fire retardent product such as mastic or joint compound - no caulk). 6). Master bedroom smokes are too close to the peak of the vaulted ceiling per NFPA 29.11.3.1(Smoke alarms or smoke detectors mounted on a peaked ceiling shall be located within 36 in. (910 mm) horizontally of the peak, but not closer than 4 in. (100 mm) vertically to the peak). 7). Anti-siphon device at hose bibbs are missing the set screw and are not secured as required. P2902.4.3 8). Garage door opener is not plugged in. Could not be safety tested or GFCI tested. 9). Garbage disposal is not plugged in. Could not be tested. 10). AHU breaker is too big. 35amp installed. (30amp required). 8/2/23: Will need attic access in Master Bedroom closet (Both Units) to view blown in insulation at Building Final Inspection. We will not be able to verify from Garage Access Panel. (walking space is too low & filled with ductwork, etc.)
BLD - BUILDING FINAL 01/23/2024 Disapproved -FEE REQUIRED RSIMS
Note: 1/23/24: Unit A: 1). Still no Insulation certificate posted or on site. 2). Garage ceiling is still not repaired/sealed properly. Material must be fire retardent or meet the minimum thickness to act as fireblock & be sealed along edges as required. (R302.11.1). Please also seal ceiling at low voltage line (as previously stated in item 5). 3). Previously listed item 6 is still not resolved properly. Unit B: 1). Garage ceiling is still not repaired/sealed properly. Material must be fire retardent or meet the minimum thickness to act as fireblock & be sealed along edges as required. (R302.11.1). 2). Previously listed item 6 is still not resolved properly. 1/17/2024 - PREVIOUS INSPECTION NOTES 1/17/24: Unit A: 1). Hall smoke detector needs temporary dust cover removed. (smokes tested & approved for operation only). 2). Range anti-tip device is not protecting Range from tip over as required. (possibly due to backsplash keeping range from wall). 3). No Insulation Certificate posted in attic space or on site. 4). Guest bath tub spout not sealed as required. FBC-P2705.1(3) 5). Holes in garage ceiling along with wall to ceiling seam behind AHU need to be sealed properly. (fire retardent product such as mastic or joint compound - no caulk). 6). Master bedroom smokes are too close to the peak of the vaulted ceiling per NFPA 29.11.3.1(Smoke alarms or smoke detectors mounted on a peaked ceiling shall be located within 36 in. (910 mm) horizontally of the peak, but not closer than 4 in. (100 mm) vertically to the peak). 7). Anti-siphon device at hose bibbs are missing the set screw and are not secured as required. P2902.4.3 8). AHU: Heater core installed is not identified as required. FBC-M1303.1 9). Left side: Meter Panel Main cover is missing nuts on bottom bolts. 10). Lanai outlet cover is painted shut. Could not test outlet. Unit B: 1). Hall smoke detector needs temporary dust cover removed. (smokes tested & approved for operation only). 2). Range anti-tip device is not protecting Range from tip over as required. (possibly due to backsplash keeping range from wall). 3). No Insulation Certificate posted in attic space or on site. 4). Guest bath tub spout not sealed as required. FBC-P2705.1(3) 5). Holes in garage ceiling along with wall to ceiling seam behind AHU need to be sealed properly. (fire retardent product such as mastic or joint compound - no caulk). 6). Master bedroom smokes are too close to the peak of the vaulted ceiling per NFPA 29.11.3.1(Smoke alarms or smoke detectors mounted on a peaked ceiling shall be located within 36 in. (910 mm) horizontally of the peak, but not closer than 4 in. (100 mm) vertically to the peak). 7). Anti-siphon device at hose bibbs are missing the set screw and are not secured as required. P2902.4.3 8). Garage door opener is not plugged in. Could not be safety tested or GFCI tested. 9). Garbage disposal is not plugged in. Could not be tested. 10). AHU breaker is too big. 35amp installed. (30amp required). 8/2/23: Will need attic access in Master Bedroom closet (Both Units) to view blown in insulation at Building Final Inspection. We will not be able to verify from Garage Access Panel. (walking space is too low & filled with ductwork, etc.)
BLD - BUILDING FINAL 01/17/2024 Disapproved -FEE REQUIRED RSIMS
Note: 1/17/24: Unit A: 1). Hall smoke detector needs temporary dust cover removed. (smokes tested & approved for operation only). 2). Range anti-tip device is not protecting Range from tip over as required. (possibly due to backsplash keeping range from wall). 3). No Insulation Certificate posted in attic space or on site. 4). Guest bath tub spout not sealed as required. FBC-P2705.1(3) 5). Holes in garage ceiling along with wall to ceiling seam behind AHU need to be sealed properly. (fire retardent product such as mastic or joint compound - no caulk). 6). Master bedroom smokes are too close to the peak of the vaulted ceiling per NFPA 29.11.3.1(Smoke alarms or smoke detectors mounted on a peaked ceiling shall be located within 36 in. (910 mm) horizontally of the peak, but not closer than 4 in. (100 mm) vertically to the peak). 7). Anti-siphon device at hose bibbs are missing the set screw and are not secured as required. P2902.4.3 8). AHU: Heater core installed is not identified as required. FBC-M1303.1 9). Left side: Meter Panel Main cover is missing nuts on bottom bolts. 10). Lanai outlet cover is painted shut. Could not test outlet. Unit B: 1). Hall smoke detector needs temporary dust cover removed. (smokes tested & approved for operation only). 2). Range anti-tip device is not protecting Range from tip over as required. (possibly due to backsplash keeping range from wall). 3). No Insulation Certificate posted in attic space or on site. 4). Guest bath tub spout not sealed as required. FBC-P2705.1(3) 5). Holes in garage ceiling along with wall to ceiling seam behind AHU need to be sealed properly. (fire retardent product such as mastic or joint compound - no caulk). 6). Master bedroom smokes are too close to the peak of the vaulted ceiling per NFPA 29.11.3.1(Smoke alarms or smoke detectors mounted on a peaked ceiling shall be located within 36 in. (910 mm) horizontally of the peak, but not closer than 4 in. (100 mm) vertically to the peak). 7). Anti-siphon device at hose bibbs are missing the set screw and are not secured as required. P2902.4.3 8). Garage door opener is not plugged in. Could not be safety tested or GFCI tested. 9). Garbage disposal is not plugged in. Could not be tested. 10). AHU breaker is too big. 35amp installed. (30amp required). 8/2/23: Will need attic access in Master Bedroom closet (Both Units) to view blown in insulation at Building Final Inspection. We will not be able to verify from Garage Access Panel. (walking space is too low & filled with ductwork, etc.)
ROW - FINAL INSPECTION 12/08/2023 APPROVED - AS NOTED TPOLACEK
Note: 12/8/23 ** CORRECTIONS MADE TREE RELOCATED DRAINAGE CONVEYANCE CLEAR 12/6/2023 - PREVIOUS INSPECTION NOTES 12/6/23 ** CORRECTIONS HAVE NOT BEEN MADE STILL NEED TO REMOVE TREE INBETWEEN #9 & #11 AS TREE IS IN COMMON SWALE CONVEYANCE. PLEASE CHECK PREVIOUS NOTES. PLEASE MAKE SURE ALL DIRT AND SILT ARE OUT OF CULVERT ENDS. NOT GOING TO FEE YOU FOR THIS INSPECTION TODAY PLEASE MAKE CORRECTIONS BEFORE PUTTING IN FOR STORM WATER FINALInspector Notes from Inspection 9465 11/28/23 THE TREES IN THE COMMON SWALE AREA WILL NEED TO BE REMOVED OR RELOCATED AS THEY CAN NOT BE IN THE DRAINAGE CONVEYANCE. THEY TOO CLOSE TO THE MIDDLE OF THE COMMON SWALE. APPROVING THIS INSPECTION AS NOTED.
U -UTILITY RESIDENTIAL FINAL 12/06/2023 FINAL APPROVED JHARDING
ROW - FINAL INSPECTION 12/06/2023 Disapproved - NO FEE TPOLACEK
Note: 12/6/23 ** CORRECTIONS HAVE NOT BEEN MADE STILL NEED TO REMOVE TREE INBETWEEN #9 & #11 AS TREE IS IN COMMON SWALE CONVEYANCE. PLEASE CHECK PREVIOUS NOTES. PLEASE MAKE SURE ALL DIRT AND SILT ARE OUT OF CULVERT ENDS. NOT GOING TO FEE YOU FOR THIS INSPECTION TODAY PLEASE MAKE CORRECTIONS BEFORE PUTTING IN FOR STORM WATER FINALInspector Notes from Inspection 9465 11/28/23 THE TREES IN THE COMMON SWALE AREA WILL NEED TO BE REMOVED OR RELOCATED AS THEY CAN NOT BE IN THE DRAINAGE CONVEYANCE. THEY TOO CLOSE TO THE MIDDLE OF THE COMMON SWALE. APPROVING THIS INSPECTION AS NOTED.
U-CROSS CONNECTION 12/06/2023 APPROVED - AS NOTED JHARDING
Note: No irrigation, no cross connections.
ROW - FINAL APRON (AFTER POUR) 12/06/2023 APPROVED TPOLACEK
Note: 12/6/23 ** PIPE GOOD, CUTS MADE, HOT PATCH GOOD. CULVERT CLEAR ____________________________________________________________________________________ Inspector Notes from Inspection 9465 11/28/23 THE TREES IN THE COMMON SWALE AREA WILL NEED TO BE REMOVED OR RELOCATED AS THEY CAN NOT BE IN THE DRAINAGE CONVEYANCE. THEY TOO CLOSE TO THE MIDDLE OF THE COMMON SWALE. APPROVING THIS INSPECTION AS NOTED.
ROW- FINAL SURVEY/GRADING CERTIFICATION 11/28/2023 APPROVED FSLADISH
Note: Inspector Notes from Inspection 9270 10/19/23 BOTH PIPES GOOD. LOOKED GOOD AT THE TIME OF THIS INSPECTION. READY TO POUR. AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS BEFORE POURING. MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved. This includes but is not limited to, the Culvert Pipe Elevation from the time of the inspection approval to the concrete pour.
ROW FIELD SURVEY /GRADING CERTIFICATION 11/28/2023 APPROVED - AS NOTED FSLADISH
Note: 11/28/23 THE TREES IN THE COMMON SWALE AREA WILL NEED TO BE REMOVED OR RELOCATED AS THEY CAN NOT BE IN THE DRAINAGE CONVEYANCE. THEY TOO CLOSE TO THE MIDDLE OF THE COMMON SWALE. APPROVING THIS INSPECTION AS NOTED.
ELECTRIC - EARLY POWER 11/01/2023 APPROVED - AS NOTED MKRASKI
Note: Emailed FPL @ 3pm
ROW- PRE-APRON (PRE-POUR) 10/19/2023 APPROVED - AS NOTED FSLADISH
Note: 10/19/23 BOTH PIPES GOOD. LOOKED GOOD AT THE TIME OF THIS INSPECTION. READY TO POUR. AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS BEFORE POURING. MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved. This includes but is not limited to, the Culvert Pipe Elevation from the time of the inspection approval to the concrete pour.
U - SEWER TIE IN 08/29/2023 APPROVED - AS NOTED MGIBSON
Note: THIS WAS A VIRTUAL INSPECTION
FIREWALL FINAL 08/18/2023 APPROVED RSIMS
Note: Inspector Notes from Inspection 2490 8/2/23: Will need attic access in Master Bedroom closet (Both Units) to view blown in insulation at Building Final Inspection. We will not be able to verify from Garage Access Panel. (walking space is too low & filled with ductwork, etc.) * Note added to Building Final Inspection.
PEP TANK INSTALLATION REQUEST 08/10/2023 APPROVED CBOWERMASTER
INSULATION 08/02/2023 APPROVED - AS NOTED RSIMS
Note: 8/2/23: Will need attic access in Master Bedroom closet (Both Units) to view blown in insulation at Building Final Inspection. We will not be able to verify from Garage Access Panel. (walking space is too low & filled with ductwork, etc.) * Note added to Building Final Inspection.
LATH/BRICK/ WATER BARRIER 07/31/2023 APPROVED RSIMS
Note: Inspector Notes from Inspection 2420 1. Unit A fill the concrete cut out for the drain pipe. 2. Unit B water distribution pipe not under test. 3. The electrical Riser diagram on Page E-1 of the prints does not match the installed riser. Please submit a revision to the building department for the change. Check for correction at early power inspection.
ALL ROUGH 07/27/2023 APPROVED - AS NOTED JWALKER
Note: 1. Unit A fill the concrete cut out for the drain pipe. 2. Unit B water distribution pipe not under test. 3. The electrical Riser diagram on Page E-1 of the prints does not match the installed riser. Please submit a revision to the building department for the change. Check for correction at early power inspection.
ROOF VALLEY & METAL 07/26/2023 APPROVED RSIMS
Note: 7/10/2023 - PREVIOUS INSPECTION NOTES 7/10/23: This is only a partial inspection. Revision for 5" x 5" step flashing still needs to be submitted & approved before full inspection can be approved. We will also, need to see the 5" x 5" step flashing before the wall veneer is installed to check for proper installation, properly sealed to wall and properly step sealed to shingles. Roof sheathing is now approved. 7/7/2023 - PREVIOUS INSPECTION NOTES 7/7/23: Cannot have Approved roof valley metal before approved roof sheathing (Inspection 2460). Also, contractor will submit revision for step flashing to be installed versus 5" x 5" flashing. 6/29/2023 - PREVIOUS INSPECTION NOTES 6/29/23: INSPECTION STOPPED! NOT READY! Cannot have approved roof & valley metal before Approved Roof Sheathing. I bump checked unit B while there and found over three areas of loose roof sheathing. You will need to check all before scheduling Inspections 2460 or 2467. Some areas marked with LS & blue arrow on wall below. Loose plywood at overhang. Unit A not complete. Also, missing all 5" x 5" flashing.
FIREWALL DRYWALL NAILING 07/24/2023 APPROVED MKRASKI
ROOF SHEATHING / BRACES/TIES/DOWN CELL 07/14/2023 APPROVED BTAYLOR
Note: 7/10/23: Roof sheathing (only) is now approved through Inspection 2467/Roof Valley Metal. 7/7/2023 - PREVIOUS INSPECTION NOTES 7/7/23: Inspection stopped. Incomplete inspection. 1). No plans in box for Inspection. 2). Previously listed loose roof sheathing checked during inspection 2467 still exists. Bump check now complete and there is additional loose roof sheathing. (Marked with LS below the area). Showed PM. Down cell - approved New inspection due to canceled inspection 3/23/2023 - PREVIOUS INSPECTION NOTES 3/23/23: Inspection Stopped! Not Ready! Framing contractor is in the process of installing truss web bracing/engineering.
ROOF VALLEY & METAL 07/10/2023 PARTIALLY APPROVED RSIMS
Note: 7/10/23: This is only a partial inspection. Revision for 5" x 5" step flashing still needs to be submitted & approved before full inspection can be approved. We will also, need to see the 5" x 5" step flashing before the wall veneer is installed to check for proper installation, properly sealed to wall and properly step sealed to shingles. Roof sheathing is now approved. 7/7/2023 - PREVIOUS INSPECTION NOTES 7/7/23: Cannot have Approved roof valley metal before approved roof sheathing (Inspection 2460). Also, contractor will submit revision for step flashing to be installed versus 5" x 5" flashing. 6/29/2023 - PREVIOUS INSPECTION NOTES 6/29/23: INSPECTION STOPPED! NOT READY! Cannot have approved roof & valley metal before Approved Roof Sheathing. I bump checked unit B while there and found over three areas of loose roof sheathing. You will need to check all before scheduling Inspections 2460 or 2467. Some areas marked with LS & blue arrow on wall below. Loose plywood at overhang. Unit A not complete. Also, missing all 5" x 5" flashing.
ROOF VALLEY & METAL 07/07/2023 Disapproved - NO FEE RSIMS
Note: 7/7/23: Cannot have Approved roof valley metal before approved roof sheathing (Inspection 2460). Previously noted loose plywood still exists along with additional areas after completing Roof sheathing bump check. Contractor will submit revision for proposed Step Flashing versus 5" x 5" flashing. 6/29/2023 - PREVIOUS INSPECTION NOTES 6/29/23: INSPECTION STOPPED! NOT READY! Cannot have approved roof & valley metal before Approved Roof Sheathing. I bump checked unit B while there and found over three areas of loose roof sheathing. You will need to check all before scheduling Inspections 2460 or 2467. Some areas marked with LS & blue arrow on wall below. Loose plywood at overhang. Unit A not complete. Also, missing all 5" x 5" flashing.
ROOF SHEATHING / BRACES/TIES/DOWN CELL 07/07/2023 Disapproved -FEE REQUIRED RSIMS
Note: 7/7/23: Inspection stopped. Incomplete inspection. 1). No plans in box for Inspection. 2). Previously listed loose roof sheathing checked during inspection 2467 still exists. Bump check now complete and there is additional loose roof sheathing. (Marked with LS below the area). Showed PM. Down cell - approved New inspection due to canceled inspection 3/23/2023 - PREVIOUS INSPECTION NOTES 3/23/23: Inspection Stopped! Not Ready! Framing contractor is in the process of installing truss web bracing/engineering.
WALL SHEATHING 07/07/2023 APPROVED RSIMS
ROOF VALLEY & METAL 06/29/2023 Disapproved -FEE REQUIRED RSIMS
Note: 6/29/23: INSPECTION STOPPED! NOT READY! Cannot have approved roof & valley metal before Approved Roof Sheathing. I bump checked unit B while there and found over three areas of loose roof sheathing. You will need to check all before scheduling Inspections 2460 or 2467. Some areas marked with LS & blue arrow on wall below. Loose plywood at overhang. Unit A not complete. Also, missing all 5" x 5" flashing.
ROOF VALLEY & METAL 06/28/2023 CANCELLED BY APPLICANT WEB
ROOF SHEATHING / BRACES/TIES/DOWN CELL 03/27/2023 CANCELLED BY APPLICANT WEB
Note: 3/23/2023 - PREVIOUS INSPECTION NOTES 3/23/23: Inspection Stopped! Not Ready! Framing contractor is in the process of installing truss web bracing/engineering.
ROOF SHEATHING / BRACES/TIES/DOWN CELL 03/23/2023 Disapproved - NO FEE RSIMS
Note: 3/23/23: Inspection Stopped! Not Ready! Framing contractor is in the process of installing truss web bracing/engineering.
FOUND SURVEY APPROVED (OFFICE) 03/22/2023 APPROVED TBAKER
TIE BEAM / LINTEL 02/14/2023 APPROVED JWALKER
Note: 2/13/2023 - PREVIOUS INSPECTION NOTES 2/13/23: 1). Window mortar beds in both units are too thick per FBC R606.3.1 (1/2" max) marked with an 'X' on ther inside. (all in unit B and all but 2 in unit A) 2). Unit B at entry down rod is not tight to dowel rod allowing movement during down cell fill.
TIE BEAM / LINTEL 02/13/2023 Disapproved - NO FEE RSIMS
Note: 2/13/23: 1). Window mortar beds in both units are too thick per FBC R606.3.1 (1/2" max) marked with an 'X' on ther inside. (all in unit B and all but 2 in unit A) 2). Unit B at entry down rod is not tight to dowel rod allowing movement during down cell fill.
MONOLITHIC SLAB 01/25/2023 APPROVED TSTAUFFACHER
Note: 1/24/2023 - PREVIOUS INSPECTION NOTES Slab and footings passed termite notification passed Compaction test results are not posted in the job box.
MONOLITHIC SLAB 01/24/2023 Disapproved - NO FEE JWALKER
Note: Slab and footings passed termite notification passed Compaction test results are not posted in the job box.
PLUMBING 1ST ROUGH UNDERGROUND 01/19/2023 APPROVED MGIBSON
Note: 1/18/2023 - PREVIOUS INSPECTION NOTES ''B'' UNIT NOT HOLDING 5' HEAD TES
GRAVITY SEWER TEST 01/19/2023 APPROVED MGIBSON
Note: 1/18/2023 - PREVIOUS INSPECTION NOTES SEE FIRTST ROUGH NOTES
GRAVITY SEWER TEST 01/18/2023 Disapproved - NO FEE MGIBSON
Note: SEE FIRTST ROUGH NOTES
PLUMBING 1ST ROUGH UNDERGROUND 01/18/2023 Disapproved -FEE REQUIRED MGIBSON
Note: ''B'' UNIT NOT HOLDING 5' HEAD TEST
WATER METER INSTALLATION REQUEST 01/04/2023 APPROVED CSTONE

Review History

Department Status Date In Date Out
ELEC COMPLETE 08/01/2023 08/01/2023
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ELEC HOLD 07/31/2023 08/01/2023
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Upload new riser diagram.
ELEC HOLD 07/28/2023 07/31/2023
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. 250 is not big enough wire for the 300 amp service. NEC 2017 Table 310.15(B)(16)
BLD COMPLETE 07/18/2023 07/21/2023
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
BADMIN INFORMATION 07/13/2023 07/13/2023
Note: Marked INFORMATION By: LIBBY MUSGROVE - - LMUSGROVE@PALMCOASTGOV.COM Wrong File Name Uploaded file name was not correct - Example: Site plan=site plan (do not add anything to the file names like numbers.)
BLD COMPLETE 07/13/2023 07/17/2023
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
BLD COMPLETE 07/10/2023 07/13/2023
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
BLD COMPLETE 06/28/2023 06/29/2023
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
BLD HOLD 06/23/2023 06/26/2023
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Provide location of draftstopping in wall section view above and along the wall assembly. Connect draftstopping comments to location using arrow indicator.
BLD HOLD 06/21/2023 06/23/2023
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Provide plan revisions showing changes to existing firewall details as well as required draftstopping details per R302.12 and materials per R302.12.1 FBC Residential 2020 7Th Edition
BLD COMPLETE 05/02/2023 05/02/2023
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ENGIN1 COMPLETE 03/22/2023 03/22/2023
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON COMPLETE 03/22/2023 03/22/2023
Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM
BADMIN INFORMATION 03/16/2023 03/16/2023
Note: Marked INFORMATION By: SCOTT THOMAS - - STHOMAS@PALMCOASTGOV.COM INCORRECT PERMIT # ON NOC
ZON COMPLETE 11/04/2022 11/04/2022
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
ENGIN1 COMPLETE 11/04/2022 11/04/2022
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
SW1 COMPLETE 11/04/2022 11/15/2022
Note: Released By: ROBERT GROSS - (386)986-4769 - RGROSS@PALMCOASTGOV.COM
ZON HOLD 10/27/2022 10/27/2022
Note: Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM Please provide the setback from AC pad on the left side to property line so we can review that it is not encroaching in the easement
ELEC COMPLETE 10/27/2022 10/27/2022
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ENGIN1 COMPLETE 10/27/2022 10/27/2022
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
SW1 COMPLETE 10/27/2022 11/03/2022
Note: Released By: ROBERT GROSS - (386)986-4769 - RGROSS@PALMCOASTGOV.COM
SW1 COMPLETE 10/19/2022 10/26/2022
Note: Released By: ROBERT GROSS - (386)986-4769 - RGROSS@PALMCOASTGOV.COM See additional notes comment.
BLD COMPLETE 10/19/2022 10/24/2022
Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM
ZON HOLD 10/19/2022 10/20/2022
Note: Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM Please provide the setback from AC pads to property lines so we can review that they are not encroaching in the easements Please provide new landscape plan showing the new AC locations with screening
ENGIN1 COMPLETE 10/19/2022 10/20/2022
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ELEC HOLD 10/19/2022 10/24/2022
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM Need correct outlet spacing in Great room. NEC 2017 210.52 2nd REQUEST
MECH COMPLETE 10/19/2022 10/20/2022
Note: Released By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM
SWALE COMPLETE 10/07/2022 02/16/2023
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
BLD HOLD 10/06/2022 10/11/2022
Note: Held By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM All comments below per the 2020 Florida Building Code PLAN REVIEW COMMENTS: Repeat Comments 1. Not on Sheet A2 states, the building is located within a wind-borne debris region. The product approvals submitted are for non-impact rated windows and doors. Provide which is correct. 2. Door between garage and residence to be a 20 minute rated door R302.5.1.
CUSVC COMPLETE 10/06/2022 10/10/2022
Note: Released By: HALEIGH HAND - -
ELEC HOLD 10/06/2022 10/06/2022
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Submit electric load calcs. 2. Need correct outlet spacing in Great room. NEC 2017 210.52
ENGIN1 COMPLETE 10/06/2022 10/07/2022
Note: Released By: JOHN HOWARD - - JHOWARD@PALMCOASTGOV.COM
LOCATE COMPLETE 10/06/2022 10/11/2022
Note: Released By: CANDACE STONE - - CSTONE@PALMCOASTGOV.COM
MECH HOLD 10/06/2022 10/06/2022
Note: Held By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM Energy calc for side A needs to have a design location of Daytona Beach
SW1 HOLD 10/06/2022 10/10/2022
Note: Held By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM NEED TO HAVE PROPOSED ELEVATIONS BETWEEN BACK OF HOUSE AND BACK PROPERTY LINE AS OF NOW THE ELEVATION AT THE HOUSE IS THE SAME AS THE PROPERTY LINE IS SO ALL WATER WILL RUN IN PATIOS NEED TO HAVE A SWALE BETWEEN THE HOUSE AND THE PROPERTY LINE
ZON COMPLETE 10/06/2022 10/07/2022
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
PLAN REVIEW - REVISION ¤32.50 02/06/2024
REINSPECTION RESIDENTIAL ¤40.00 02/06/2024
REINSPECTION RESIDENTIAL ¤40.00 02/06/2024
REINSPECTION RESIDENTIAL ¤40.00 02/06/2024
REINSPECTION RESIDENTIAL ¤40.00 02/06/2024
REINSPECTION RESIDENTIAL ¤40.00 02/06/2024
CONNECTION FEES ¤2,155.76 11/30/2022
FIRE IMPACT FEE ADMIN ¤25.23 11/30/2022
FIRE IMPACT FEE ADMIN (¤25.23) 11/30/2022
IMPACT FEE FIRE ¤841.04 11/30/2022
IMPACT FEE PARKS ¤3,538.30 11/30/2022
IMPACT FEE SCHOOL ¤10,900.00 11/30/2022
IMPACT FEE TRANSPORTATION ¤2,738.00 11/30/2022
WATER -IRRIGATION INSPECTION ¤50.00 11/30/2022
PARKS IMPACT FEE ADMIN ¤106.15 11/30/2022
PARKS IMPACT FEE ADMIN (¤106.15) 11/30/2022
SURCHARGE FS 533.721 ¤4.19 11/30/2022
SURCHARGE - FS 468.631 ¤6.29 11/30/2022
SW ENG - FOUNDATION SURVEY ¤20.00 11/30/2022
SW ENG INSPECTION 80 ¤80.00 11/30/2022
SW ENG PRE APRON ¤30.00 11/30/2022
SW ENG - REVIEW 20 ¤20.00 11/30/2022
SW ENG RES REVIEW 200 ¤200.00 11/30/2022
TRANS IMPACT FEE ADMIN (¤82.14) 11/30/2022
TRANS IMPACT FEE ADMIN ¤82.14 11/30/2022
SEWER CREDIT (¤1,700.00) 11/30/2022
SEWER INSPECTION ¤25.00 11/30/2022
SEWER CAPITAL FACILITY ¤9,879.52 11/30/2022
WATER CAPITAL FACILITY FEE ¤7,253.00 11/30/2022
SITE PLAN 30 ¤30.00 11/30/2022
WATER- TURN ON ¤50.00 11/30/2022
ADJUSTMENT 50% (¤666.29) 11/30/2022
ADMINISTRATIVE RESIDENTIAL ¤30.00 11/30/2022
INSPECTION - RESIDENTIAL ¤1,014.75 11/30/2022
PLAN REVIEW - RESIDENTIAL ¤287.82 11/30/2022
Fees Total Due: ¤0.00 Total Paid: ¤37,019.88