Permit #2022100279
Permit Details
Status: COED
| Parcel Id: 07-11-31-7034-00060-0020 |
| CONDITIONED SPACE: 2860 sqft |
| OPENED PORCH (WITH ROOF) : 348 sqft |
| GARAGE: 912 sqft |
| Total Square Footage: 4120 sqft |
| Block: 00060 |
| Subdivision: 2165 - SECTION 34-EASTHAMPTON |
| Job Phone: 386-237-8427 |
| Location Address: 11 EMPIRE LN |
| Type: DU - DUPLEX |
| Issue Date: 11/30/2022 |
| NOC: RECORDED |
| Applicant name: JAY DARREN CURBOW |
| Owner: BLUE WATER PROPERTIES II LLC |
|
Address PO BOX 9 CISSNA PARK, IL 60924 |
| Lot: 0020 |
| Contracted Stated Job Value: ¤245,250.00 |
| Job Description: Duplex |
| Type: CN |
Contractor
BLUE WATER HOMES INC
| Status | Location Address | State License Number | Phone |
| ACTIVE |
4881 PALM COAST PARKWAY NW UNIT 1 PALM COAST, FL 32137 |
CBC1258679 (Exp: 08/31/2026) | 386-445-3405 |
Sub Contractors
WILLIAM FRANK DUDLEY JR.
| Status | Location Address | State License Number | Phone |
| ACTIVE |
P.O. BOX 978 Bunnell, FL 32110 |
EC0003177 (Exp: 08/31/2026) | (386)437-3068 |
JEFFREY TROY SABAKA
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
2191 DEERWOOD ACRES DR ST AUGUSTINE, FL 32084 |
CFC1427439 (Exp: 08/31/2026) | 904-838-2218 | 904-819-0965 |
BRETT CHRISTIAN GIBSON
| Status | Location Address | State License Number | Phone |
| ACTIVE |
250 SEGOVIA RD ST AUGUSTINE, FL 32086 |
CAC1818423 (Exp: 08/31/2026) | 904-229-8131 |
JACK DOUGLAS LANIER
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
485 COMMERCE WAY LONGWOOD , FL 32750 |
CCC058022 (Exp: 08/31/2026) | (321)441-2300 | (321)441-2313 |
Inspection History
| Type | Request Date | Result | Inspector |
| BLD - BUILDING FINAL | 03/14/2024 | FINAL APPROVED | BTAYLOR |
| Note: 3/12/2024 - PREVIOUS INSPECTION NOTES 8/2/23: Will need attic access in Master Bedroom closet (Both Units) to view blown in insulation at Building Final Inspection. We will not be able to verify from Garage Access Panel. (walking space is too low & filled with ductwork, etc.) 11/2/23 Note to contractor: The 2 ODU's /Heat pump's at both units have been installed in front of the bedrooms emergency escape and rescue openings. A clear path to a yard or court are required. The 2 units will need to be relocated prior to final building inspection. 3-12-24 1. Unit A no hot water in kitchen. 2. Unit A middle bedroom window does not operate. 3. Unit A middle bathroom shower valves are reversed. 4. Unit A master bedroom window does not operate. 5. Unit B no energy cals. 6. Unit B no hot water in kitchen. | |||
| BLD - BUILDING FINAL | 03/12/2024 | Disapproved - NO FEE | BTAYLOR |
| Note: 8/2/23: Will need attic access in Master Bedroom closet (Both Units) to view blown in insulation at Building Final Inspection. We will not be able to verify from Garage Access Panel. (walking space is too low & filled with ductwork, etc.) 11/2/23 Note to contractor: The 2 ODU's /Heat pump's at both units have been installed in front of the bedrooms emergency escape and rescue openings. A clear path to a yard or court are required. The 2 units will need to be relocated prior to final building inspection. 3-12-24 1. Unit A no hot water in kitchen. 2. Unit A middle bedroom window does not operate. 3. Unit A middle bathroom shower valves are reversed. 4. Unit A master bedroom window does not operate. 5. Unit B no energy cals. 6. Unit B no hot water in kitchen. | |||
| U-CROSS CONNECTION | 12/06/2023 | APPROVED - AS NOTED | JHARDING |
| Note: No irrigation, no cross connections. | |||
| ROW - FINAL APRON (AFTER POUR) | 12/06/2023 | APPROVED | TPOLACEK |
| Note: 12/6/23 ** PIPE IS GOOD, CUTS ARE MADE, CULVERT CLEAR, HOT PATCH COMPLETED | |||
| ROW - FINAL INSPECTION | 12/06/2023 | APPROVED - AS NOTED | TPOLACEK |
| Note: 12/6/23 APPROVING THIS INSPECTION AS NOTED PLEASE CLEAN OUT CULVERT PIPE ENDS OF DIRT AND SILT. | |||
| U -UTILITY RESIDENTIAL FINAL | 12/06/2023 | FINAL APPROVED | JHARDING |
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 11/28/2023 | APPROVED | FSLADISH |
| ROW FIELD SURVEY /GRADING CERTIFICATION | 11/28/2023 | APPROVED | FSLADISH |
| Note: 11/28/23 At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved. | |||
| ELECTRIC - EARLY POWER | 11/02/2023 | APPROVED - AS NOTED | JWALKER |
| Note: Note to contractor: The 2 ODU's /Heat pump's at both units have been installed in front of the bedrooms emergency escape and rescue openings. A clear path to a yard or court are required. The 2 units will need to be relocated prior to final building inspection. 11/1/2023 - PREVIOUS INSPECTION NOTES Left side unit is locked need access for inspection | |||
| ELECTRIC - EARLY POWER | 11/01/2023 | Disapproved - NO FEE | MKRASKI |
| Note: Left side unit is locked need access for inspection | |||
| ROW- PRE-APRON (PRE-POUR) | 10/30/2023 | APPROVED | PFLANAGAN |
| Note: IT'S YOUR RESPONSIBILITY TO CHECK THE CULVERT ELEVATIONS BEFORE POURING CONCRETE ALL CONCRETE NEEDS TO BE A MINIMUM OF 3000PSI WITH FIBER OR WITH METAL MESH IN THE CONCRETE TO MEET ALL CITY'S STANDARTS At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved. | |||
| U - SEWER TIE IN | 08/29/2023 | APPROVED - AS NOTED | MGIBSON |
| Note: THIS WAS A VIRTUAL INSPECTION | |||
| FIREWALL FINAL | 08/29/2023 | APPROVED | RSIMS |
| Note: 8/24/2023 - PREVIOUS INSPECTION NOTES 8/24/23: Need trash cleaned up around full build site before any additional inspections will be approved. ** drywall anchoring Nails/screws are not consistently spaced at 7" OC intervals as required by R702.3.5. | |||
| FIREWALL FINAL | 08/24/2023 | Disapproved - NO FEE | RSIMS |
| Note: 8/24/23: Need trash cleaned up around full build site before any additional inspections will be approved. ** drywall anchoring Nails/screws are not consistently spaced at 7" OC intervals as required by R702.3.5. | |||
| PEP TANK INSTALLATION REQUEST | 08/10/2023 | APPROVED | CBOWERMASTER |
| INSULATION | 08/08/2023 | APPROVED | RSIMS |
| Note: 8/7/2023 - PREVIOUS INSPECTION NOTES 8/7/23: Unit A: The wall at the bathroom entry has wires through the top plate that do not have sufficient FS. Previously marked on the inside of the bathroom side of the 2"x4" wall is now marked on the outside of the same wall. Call me with any questions. PVC conduit previously noted is not firestopped at the opening of the pipes on both sides creating a raceway for fire & smoke. Please fill the pipe area where wires enter. Unit B: PVC conduit same note as Unit A. Previously listed item 4 the firestop is not in the correct area. There is still a large gap (on both sides) that is unimpeded to the attic space. Marked it additionally. 8/3/2023 - PREVIOUS INSPECTION NOTES 8/3/23: Unit A: 1). Insufficient firestop at top plate penetration for wires into attic space - left room. Marked with FSI on studs below. 2). Firestop at bathtub pack out wall needs to be complete. Still open area into attic at end. 3). Please firestop electrical PVC conduit that goes under the concrete floor on both ends. 4). Firestop needed at top plate of pack out wall at entry to bedrooms/bathroom. Marked on studs below with FS. Unit B: 1). Firestop needed at top plate of pack out wall at entry to bedrooms/bathroom. Marked on the studs below with FS. 2). Please firestop electrical PVC pipe that goes under the concrete floor at both ends. 3). Firestop at bathtub pack out walls needs to be complete where open to the attic speace on the end. Marked with FS below. 8/2/23: Will need attic access in Master Bedroom closet (Both Units) to view blown in insulation at Building Final Inspection. We will not be able to verify from Garage Access Panel. (walking space is too low & filled with ductwork, etc.) RS - * Note added to Building Final Inspection. | |||
| INSULATION | 08/07/2023 | Disapproved - NO FEE | RSIMS |
| Note: 8/7/23: Unit A: The wall at the bathroom entry has wires through the top plate that do not have sufficient FS. Previously marked on the inside of the bathroom side of the 2"x4" wall is now marked on the outside of the same wall. Call me with any questions. PVC conduit previously noted is not firestopped at the opening of the pipes on both sides creating a raceway for fire & smoke. Please fill the pipe area where wires enter. Unit B: PVC conduit same note as Unit A. Previously listed item 4 the firestop is not in the correct area. There is still a large gap (on both sides) that is unimpeded to the attic space. Marked it additionally. 8/3/2023 - PREVIOUS INSPECTION NOTES 8/3/23: Unit A: 1). Insufficient firestop at top plate penetration for wires into attic space - left room. Marked with FSI on studs below. 2). Firestop at bathtub pack out wall needs to be complete. Still open area into attic at end. 3). Please firestop electrical PVC conduit that goes under the concrete floor on both ends. 4). Firestop needed at top plate of pack out wall at entry to bedrooms/bathroom. Marked on studs below with FS. Unit B: 1). Firestop needed at top plate of pack out wall at entry to bedrooms/bathroom. Marked on the studs below with FS. 2). Please firestop electrical PVC pipe that goes under the concrete floor at both ends. 3). Firestop at bathtub pack out walls needs to be complete where open to the attic speace on the end. Marked with FS below. 8/2/23: Will need attic access in Master Bedroom closet (Both Units) to view blown in insulation at Building Final Inspection. We will not be able to verify from Garage Access Panel. (walking space is too low & filled with ductwork, etc.) RS - * Note added to Building Final Inspection. | |||
| INSULATION | 08/03/2023 | Disapproved - NO FEE | RSIMS |
| Note: 8/3/23: Unit A: 1). Insufficient firestop at top plate penetration for wires into attic space - left room. Marked with FSI on studs below. 2). Firestop at bathtub pack out wall needs to be complete. Still open area into attic at end. 3). Please firestop electrical PVC conduit that goes under the concrete floor on both ends. 4). Firestop needed at top plate of pack out wall at entry to bedrooms/bathroom. Marked on studs below with FS. Unit B: 1). Firestop needed at top plate of pack out wall at entry to bedrooms/bathroom. Marked on the studs below with FS. 2). Please firestop electrical PVC pipe that goes under the concrete floor at both ends. 3). Firestop at bathtub pack out walls needs to be complete where open to the attic speace on the end. Marked with FS below. 8/2/23: Will need attic access in Master Bedroom closet (Both Units) to view blown in insulation at Building Final Inspection. We will not be able to verify from Garage Access Panel. (walking space is too low & filled with ductwork, etc.) RS - * Note added to Building Final Inspection. | |||
| INSULATION | 08/02/2023 | CANCELLED BY APPLICANT | WEB |
| LATH/BRICK/ WATER BARRIER | 07/31/2023 | APPROVED | RSIMS |
| Note: Inspector Notes from Inspection 2420 The electrical riser diagram on page E-1 of the prints does not match the riser installed. Please submit a revison to the building department for the change. Check for correction at early power inspection. | |||
| ALL ROUGH | 07/27/2023 | APPROVED - AS NOTED | JWALKER |
| Note: The electrical riser diagram on page E-1 of the prints does not match the riser installed. Please submit a revison to the building department for the change. Check for correction at early power inspection. | |||
| ROOF VALLEY & METAL | 07/26/2023 | APPROVED | RSIMS |
| Note: 7/10/2023 - PREVIOUS INSPECTION NOTES 7/10/23: This is only a partial inspection. Revision for 5" x 5" step flashing still needs to be submitted & approved before full inspection can be approved. We will also, need to see the 5" x 5" step flashing before the wall veneer is installed to check for proper installation & sealing to wall and step sealed to shingles. Roof sheathing is now approved. 7/7/2023 - PREVIOUS INSPECTION NOTES 7/7/23: Cannot have Approved roof valley metal before approved roof sheathing (Inspection 2460). Also, contractor will submit revision for step flashing to be installed versus 5" x 5" flashing. 6/29/2023 - PREVIOUS INSPECTION NOTES 6/29/23: Cannot have Approved roof valley metal before approved roof sheathing (Inspection 2460). | |||
| FIREWALL DRYWALL NAILING | 07/24/2023 | APPROVED | MKRASKI |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 07/14/2023 | APPROVED | BTAYLOR |
| Note: 7/10/23: Roof sheathing (only) approved during Inspection 2470/Roof Valley Metal. 7/7/2023 - PREVIOUS INSPECTION NOTES 7/7/23: Previously noted loose roof sheathing still exists. Walked with PM. 1). Truss G05 is missing web bracing/engineering as required. Revision does not show plywood repair done. 2). Truss G03 is missing a splice plate at joint. Will require Mitek approved repair. Ties & down cell - approved 6/29/2023 - PREVIOUS INSPECTION NOTES 6/29/23: Inspection stopped! Incomplete Inspection. Walked with PM to discuss items needed. Straps missing and/or not fully nailed. Loose roof sheathing in multiple places, 3 ply girders not nailed properly, etc. Only Roof sheathing bump check complete. Areas marked on wall below. | |||
| ROOF VALLEY & METAL | 07/10/2023 | PARTIALLY APPROVED | RSIMS |
| Note: 7/10/23: This is only a partial inspection. Revision for 5" x 5" step flashing still needs to be submitted & approved before full inspection can be approved. We will also, need to see trhe 5" x 5" step flashing before the wall veneer is installed to check for proper installation, proper sealing to wall and proper step sealing to shingles. Roof sheathing is now approved. 7/7/2023 - PREVIOUS INSPECTION NOTES 7/7/23: Cannot have Approved roof valley metal before approved roof sheathing (Inspection 2460). Also, contractor will submit revision for step flashing to be installed versus 5" x 5" flashing. 6/29/2023 - PREVIOUS INSPECTION NOTES 6/29/23: Cannot have Approved roof valley metal before approved roof sheathing (Inspection 2460). | |||
| ROOF VALLEY & METAL | 07/07/2023 | Disapproved - NO FEE | RSIMS |
| Note: 7/7/23: Cannot have Approved roof valley metal before approved roof sheathing (Inspection 2460). Also, contractor will submit revision for step flashing to be installed versus 5" x 5" flashing. 6/29/2023 - PREVIOUS INSPECTION NOTES 6/29/23: Cannot have Approved roof valley metal before approved roof sheathing (Inspection 2460). | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 07/07/2023 | Disapproved -FEE REQUIRED | RSIMS |
| Note: 7/7/23: Previously noted loose roof sheathing still exists. Walked with PM. 1). Truss G05 is missing web bracing/engineering as required. Revision does not show plywood repair done. 2). Truss G03 is missing a splice plate at joint. Will require Mitek approved repair. Ties & down cell - approved 6/29/2023 - PREVIOUS INSPECTION NOTES 6/29/23: Inspection stopped! Incomplete Inspection. Walked with PM to discuss items needed. Straps missing and/or not fully nailed. Loose roof sheathing in multiple places, 3 ply girders not nailed properly, etc. Only Roof sheathing bump check complete. Areas marked on wall below. | |||
| WALL SHEATHING | 06/29/2023 | APPROVED | RSIMS |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 06/29/2023 | Disapproved - NO FEE | RSIMS |
| Note: 6/29/23: Inspection stopped! Incomplete Inspection. Walked with PM to discuss items needed. Straps missing and/or not fully nailed. Loose roof sheathing in multiple places, 3 ply girders not nailed properly, etc. Only Roof sheathing bump check complete. Areas marked on wall below. | |||
| ROOF VALLEY & METAL | 06/29/2023 | Disapproved - NO FEE | RSIMS |
| Note: 6/29/23: Cannot have Approved roof valley metal before approved roof sheathing (Inspection 2460). | |||
| ROOF VALLEY & METAL | 06/28/2023 | CANCELLED BY APPLICANT | WEB |
| TIE BEAM / LINTEL | 02/22/2023 | APPROVED | RSIMS |
| FOUND SURVEY APPROVED (OFFICE) | 02/21/2023 | APPROVED | TDOAK |
| MONOLITHIC SLAB | 02/06/2023 | APPROVED | RSIMS |
| Note: 2/3/2023 - PREVIOUS INSPECTION NOTES Footing beginning to collapse due to rain Chairs along front wall right side are crushed down, does not meet 3" clearance | |||
| MONOLITHIC SLAB | 02/03/2023 | Disapproved - NO FEE | TSTAUFFACHER |
| Note: Footing beginning to collapse due to rain Chairs along front wall right side are crushed down, does not meet 3" clearance | |||
| PLUMBING 1ST ROUGH UNDERGROUND | 01/19/2023 | APPROVED | MGIBSON |
| GRAVITY SEWER TEST | 01/19/2023 | APPROVED | MGIBSON |
| WATER METER INSTALLATION REQUEST | 01/04/2023 | APPROVED | CSTONE |
Review History
| Department | Status | Date In | Date Out |
| ELEC | COMPLETE | 07/31/2023 | 08/01/2023 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ELEC | HOLD | 07/28/2023 | 07/31/2023 |
| Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. 250 Is not big enough wire for the 300 amp service. NEC 2017 Table 310.15(B)(16) | |||
| BLD | COMPLETE | 07/18/2023 | 07/21/2023 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| BADMIN | INFORMATION | 07/13/2023 | 07/13/2023 |
| Note: Marked INFORMATION By: LIBBY MUSGROVE - - LMUSGROVE@PALMCOASTGOV.COM Wrong File Name Uploaded file name was not correct - Example: Site plan=site plan (do not add anything to the file names like numbers.) | |||
| BLD | COMPLETE | 07/13/2023 | 07/17/2023 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 07/10/2023 | 07/13/2023 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 06/28/2023 | 06/29/2023 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| BLD | HOLD | 06/23/2023 | 06/26/2023 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Provide location of draftstopping in wall section view above and along the wall assembly. Connect draftstopping comments to location using arrow indicator. | |||
| BLD | HOLD | 06/21/2023 | 06/23/2023 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Provide plan revisions showing changes to existing firewall details as well as required draftstopping details per R302.12 and materials per R302.12.1 FBC Residential 2020 7Th Edition | |||
| BLD | COMPLETE | 05/02/2023 | 05/02/2023 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| BADMIN | INFORMATION | 03/16/2023 | 03/16/2023 |
| Note: Marked INFORMATION By: SCOTT THOMAS - - STHOMAS@PALMCOASTGOV.COM INCORRECT # ON NOC | |||
| ENGIN1 | COMPLETE | 02/21/2023 | 02/21/2023 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 02/21/2023 | 02/21/2023 |
| Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 10/27/2022 | 10/27/2022 |
| Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM | |||
| ELEC | COMPLETE | 10/20/2022 | 10/24/2022 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 10/20/2022 | 10/20/2022 |
| Note: Released By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM | |||
| ZON | HOLD | 10/20/2022 | 10/20/2022 |
| Note: Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM Please provide new landscape plan showing new AC pad locations | |||
| BLD | COMPLETE | 10/20/2022 | 10/24/2022 |
| Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 10/20/2022 | 10/20/2022 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 10/20/2022 | 10/27/2022 |
| Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM | |||
| SWALE | COMPLETE | 10/07/2022 | 02/16/2023 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| BLD | HOLD | 10/06/2022 | 10/11/2022 |
| Note: Held By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM All comments below per the 2020 Florida Building Code PLAN REVIEW COMMENTS: Repeat Comments 1. Not on Sheet A2 states, the building is located within a wind-borne debris region. The product approvals submitted are for non-impact rated windows and doors. Provide which is correct. 2. Door between garage and residence to be a 20 minute rated door R302.5.1. | |||
| CUSVC | COMPLETE | 10/06/2022 | 10/10/2022 |
| Note: Released By: HALEIGH HAND - - | |||
| ELEC | HOLD | 10/06/2022 | 10/06/2022 |
| Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Submit electric load calcs. 2. Need correct outlet spacing in Great room. NEC 2017 210.52 | |||
| ENGIN1 | COMPLETE | 10/06/2022 | 10/07/2022 |
| Note: Released By: JOHN HOWARD - - JHOWARD@PALMCOASTGOV.COM | |||
| LOCATE | COMPLETE | 10/06/2022 | 10/11/2022 |
| Note: Released By: CANDACE STONE - - CSTONE@PALMCOASTGOV.COM | |||
| MECH | HOLD | 10/06/2022 | 10/06/2022 |
| Note: Held By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM Energy calc for side A needs to have a design location of Daytona Beach | |||
| SW1 | COMPLETE | 10/06/2022 | 10/10/2022 |
| Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM | |||
| ZON | HOLD | 10/06/2022 | 10/07/2022 |
| Note: Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM Ac pad location on floor plan doesn't match site and landscape plan location |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| PLAN REVIEW - REVISION | ¤32.50 | 03/14/2024 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 03/14/2024 |
| CONNECTION FEES | ¤2,155.76 | 11/30/2022 |
| FIRE IMPACT FEE ADMIN | ¤12.62 | 11/30/2022 |
| FIRE IMPACT FEE ADMIN | (¤12.62) | 11/30/2022 |
| IMPACT FEE FIRE | ¤841.04 | 11/30/2022 |
| IMPACT FEE PARKS | ¤3,538.30 | 11/30/2022 |
| IMPACT FEE SCHOOL | ¤10,900.00 | 11/30/2022 |
| IMPACT FEE TRANSPORTATION | ¤2,738.00 | 11/30/2022 |
| WATER -IRRIGATION INSPECTION | ¤50.00 | 11/30/2022 |
| PARKS IMPACT FEE ADMIN | ¤106.15 | 11/30/2022 |
| PARKS IMPACT FEE ADMIN | (¤106.15) | 11/30/2022 |
| SURCHARGE FS 533.721 | ¤4.19 | 11/30/2022 |
| SURCHARGE - FS 468.631 | ¤6.29 | 11/30/2022 |
| SW ENG - FOUNDATION SURVEY | ¤20.00 | 11/30/2022 |
| SW ENG INSPECTION 80 | ¤80.00 | 11/30/2022 |
| SW ENG PRE APRON | ¤30.00 | 11/30/2022 |
| SW ENG - REVIEW 20 | ¤20.00 | 11/30/2022 |
| SW ENG RES REVIEW 200 | ¤200.00 | 11/30/2022 |
| TRANS IMPACT FEE ADMIN | ¤105.84 | 11/30/2022 |
| TRANS IMPACT FEE ADMIN | (¤105.84) | 11/30/2022 |
| SEWER CREDIT | (¤1,700.00) | 11/30/2022 |
| SEWER INSPECTION | ¤25.00 | 11/30/2022 |
| SEWER CAPITAL FACILITY | ¤9,879.52 | 11/30/2022 |
| WATER CAPITAL FACILITY FEE | ¤7,253.00 | 11/30/2022 |
| SITE PLAN 30 | ¤30.00 | 11/30/2022 |
| WATER- TURN ON | ¤50.00 | 11/30/2022 |
| ADJUSTMENT 50% | (¤666.29) | 11/30/2022 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 11/30/2022 |
| INSPECTION - RESIDENTIAL | ¤1,014.75 | 11/30/2022 |
| PLAN REVIEW - RESIDENTIAL | ¤287.82 | 11/30/2022 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤36,859.88 |