I want to search for...

Permit #2022100312

Permit Details

Status: COED

Parcel Id: 07-11-31-7034-00040-0140
CONDITIONED SPACE: 2692 sqft
OPENED PORCH (WITH ROOF) : 116 sqft
OPENED PORCH (WITH ROOF) : 306 sqft
GARAGE: 1048 sqft
Total Square Footage: 4162 sqft
Block: 00040
Subdivision: 2165 - SECTION 34-EASTHAMPTON
Job Phone: 407-912-8154
Location Address: 26 EMERALD LN
Type: DU - DUPLEX
Issue Date: 04/06/2023
NOC: RECORDED
Applicant name: JUAN CARLOS HENAO-ARISTIZABAL
Owner: MOTYKA LISA A & RONALD A MOTYKA & JAMES R THRALL J

Address

UNIT B

PALM COAST, FL 32164

Address

10 EMMONS LANE

PALM COAST, FL 32164

Lot: 0140
Contracted Stated Job Value: ¤390,000.00
Job Description: DUPLEX
Type: CN

Contractor

QUEST ROOFING & CONSTRUCTION, LLC
Status Location Address State License Number Phone
ACTIVE

69 CARRIAGE CREEK WAY

ORMOND BEACH, FL 32174

CGC1525988 (Exp: 08/31/2026) 407-912-8154

Sub Contractors

FERNANDO MEZA SR
Status Location Address State License Number Phone
ACTIVE

457 CHELSEA PLACE AVE

ORMOND BEACH, FL 32174

EC13003906 (Exp: 08/31/2026) 386-241-5211
JUAN CARLOS HENAO-ARISTIZABAL
Status Location Address State License Number Phone
ACTIVE

69 CARRIAGE CREEK WAY

ORMOND BEACH, FL 32174

CCC1331523 (Exp: 08/31/2026) 407-912-8154
MICHAEL FRANK MORELLO
Status Location Address State License Number Phone Fax
ACTIVE

2 HARGROVE GRADE

PALM COAST, FL 32164

CAC1819466 (Exp: 08/31/2026) 386-445-5023 386-446-4614
JUAN CARLOS GONZALEZ
Status Location Address State License Number
ACTIVE

1328 COUNTY ROAD 308

CRESCENT CITY, FL 32112

RF11067806 (Exp: 08/31/2027)

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 02/10/2025 APPROVED CVANSTRAHLEN
BLD - BUILDING FINAL 02/03/2025 Disapproved -FEE REQUIRED CVANSTRAHLEN
Note: #1-NEC 210.8-NEEDS GFCI PROTECTION ,Unit A and B all exterior outlets recepticles need to be GFCI #2-NEC 210.8-NEEDS GFCI PROTECTION -Unit A and B refrigerator and microwave recepticle outlet need to be GFCI #3- Unit A and B , Ac and Heat E-cals model # umbers do not match what is install on the property , #4-FBC-R . 302.6 seal all garage penetration , wall and ceiling ( low voltage wire AHU Plenum conduit )
U -UTILITY RESIDENTIAL FINAL 02/03/2025 FINAL APPROVED LFITZGERALD
Note: Inspector Notes from Inspection 9035 NO IRR. NO CC
ROW - FINAL INSPECTION 01/31/2025 APPROVED GBERTOLA
Note: AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. THIS INCLUDES BUT IS NOT LIMITED TO THE CULVERT PIPE ELEVATION APPROVAL FOR THE CONCRETE POUR.
ROW - FINAL APRON (AFTER POUR) 01/31/2025 APPROVED GBERTOLA
Note: AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. THIS INCLUDES BUT IS NOT LIMITED TO THE CULVERT PIPE ELEVATION APPROVAL FOR THE CONCRETE POUR.
ROW- FINAL SURVEY/GRADING CERTIFICATION 01/31/2025 APPROVED GBERTOLA
Note: AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. THIS INCLUDES BUT IS NOT LIMITED TO THE CULVERT PIPE ELEVATION APPROVAL FOR THE CONCRETE POUR.
ROW FIELD SURVEY /GRADING CERTIFICATION 01/31/2025 APPROVED GBERTOLA
Note: AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. THIS INCLUDES BUT IS NOT LIMITED TO THE CULVERT PIPE ELEVATION APPROVAL FOR THE CONCRETE POUR. +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 1/30/2025 - PREVIOUS INSPECTION NOTES 1/30/25 LET CONTRACTOR KNOW THAT YOU CANNOT HAVE A FIELD SURVEY INSPECTION UNTIL AFTER A FINAL SURVEY HAS BEEN SUBMITTED AND PASSED. CACELING INSPECTION AT HIS REQUEST. HE WII SUBMIT FOR A FINAL SURVEY INSPECTION. ____________________________________________________________________________________________________________________________ 1/24/2025 - PREVIOUS INSPECTION NOTES
ROW FIELD SURVEY /GRADING CERTIFICATION 01/30/2025 CANCELLED BY APPLICANT FSLADISH
Note: 1/30/25 LET CONTRACTOR KNOW THAT YOU CANNOT HAVE A FIELD SURVEY INSPECTION UNTIL AFTER A FINAL SURVEY HAS BEEN SUBMITTED AND PASSED. CACELING INSPECTION AT HIS REQUEST. HE WII SUBMIT FOR A FINAL SURVEY INSPECTION. ____________________________________________________________________________________________________________________________ 1/24/2025 - PREVIOUS INSPECTION NOTES
U-CROSS CONNECTION 01/30/2025 APPROVED - AS NOTED BWRIGHT
Note: NO IRR. NO CC
ROW FIELD SURVEY /GRADING CERTIFICATION 01/24/2025 CANCELLED BY APPLICANT PFLANAGAN
ROW- PRE-APRON (PRE-POUR) 12/31/2024 APPROVED FSLADISH
Note: 12/31/24 PIPE ELEVATIONS GOOD AT THE TIME OF THIS INSPECTION. AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. AT THE TIME OF THIS INSPECTION ALL MINIMUM COPC REQUIEMENT ARE MET. BUILDER TO BE HELD RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. THIS INCLUDES BUT IS NOT LIMITED TO THE CULVERT PIPE ELEVATION APPROVAL FOR THE CONCRETE POUR. Inspector Notes from Inspection 9470 10/17/24 I AM APPROVING THIS AS NOTED THAT YOU WILL MAINTAIN THE SWALE TO KEEP IT OPEN, FLOWING AND FREE FROM OBSTRUCTION AS REQUIRED. _______________________________________________________________________________________________________________________ 10/14/2024 - PREVIOUS INSPECTION NOTES 10/14/24 I HAVE READ YOUR NOTE AND WILL PARTIALLY APPROVE YOUR DRAINAGE AT THIS TIME. MAKE SURE THAT YOU KEEP THE SWALE OPEN AND FLOWING. I WILL REINSPECT ON 10/18/24 TO MAKE SURE IT IS STILL FLOWING WITHOUT OBSRTUCTION. __________________________________________________________________________________________________________________________ 10/7/2024 - PREVIOUS INSPECTION NOTES 10/7/24 YOU WILL NEED TO INSTALL A MINIMUM 12" DIAMETER TEMPORARY CULVERT PIPE AND/ OR KEEP YOUR SWALE GRADED DAILY OR A NECCESSARY TO MAINTIAN POSITIVE SWALE DRAINAGE FLOW. YOU NEED TO REMOVE PORTA POTTY FROM ROW AND PUT IT ON YOUR SITE. I WILL BE BACK FOR COMPLIANCE REINSPECTION ON 10/11/24.
GRAVITY SEWER TEST 12/10/2024 APPROVED MGIBSON
Note: Inspector Notes from Inspection 2060 4/25/2023 - PREVIOUS INSPECTION NOTES GOLDEN MAGNOILIA CALLED AND CANCELLED HAVE PORTABLE RESTROOM BY NEXT INSPECTION
U - SEWER TIE IN 12/10/2024 APPROVED MGIBSON
Note: Inspector Notes from Inspection 2060 4/25/2023 - PREVIOUS INSPECTION NOTES GOLDEN MAGNOILIA CALLED AND CANCELLED HAVE PORTABLE RESTROOM BY NEXT INSPECTION
PEP TANK INSTALLATION REQUEST 11/18/2024 APPROVED CBOWERMASTER
Note: 10/4/2024 3:33:59 PM- PREVIOUS INSPECTION NOTES temp power pole in the way
ELECTRIC - EARLY POWER 11/07/2024 APPROVED CVANSTRAHLEN
Note: Inspector Notes from Inspection 2170 5/22/24: FPL emailed at @ 14:45. Approved for Temporaray Pole power. 5/14/2024 - PREVIOUS INSPECTION NOTES 5/14/24: 1). Silt fence is incomplete and damaged. 3 sides minimum required. FBC 3307.1 (3307.1Protection required. Adjoining public and private property shall be protected from damage during construction, remodeling and demolition work.) 2). Need overgrowth throughout entire site along with, trash & debris removed to make site safe for inspections. 3). Dumpster required throughout build per City requirements. 4). Need a portable toilet on site throughout build. TOILET FACILITIES FOR WORKERS 311.1 General. Toilet facilities shall be provided for construction workers and such facilities shall be maintained in a sanitary condition. Construction worker toilet facilities of the nonsewer type shall conform to ANSI Z4.3.
ELECTRIC - EARLY POWER 10/31/2024 Disapproved - NO FEE PKNAPIK
Note: 10/31/2024 1. Unit A lanai outlet missing plate. 2. Fix silt fence. FBC 3307.1 3. Overgrowth, trash, and debris needs to be cleaned up. Inspector Notes from Inspection 2170 5/22/24: FPL emailed at @ 14:45. Approved for Temporaray Pole power. 5/14/2024 - PREVIOUS INSPECTION NOTES 5/14/24: 1). Silt fence is incomplete and damaged. 3 sides minimum required. FBC 3307.1 (3307.1Protection required. Adjoining public and private property shall be protected from damage during construction, remodeling and demolition work.) 2). Need overgrowth throughout entire site along with, trash & debris removed to make site safe for inspections. 3). Dumpster required throughout build per City requirements. 4). Need a portable toilet on site throughout build. TOILET FACILITIES FOR WORKERS 311.1 General. Toilet facilities shall be provided for construction workers and such facilities shall be maintained in a sanitary condition. Construction worker toilet facilities of the nonsewer type shall conform to ANSI Z4.3.
INSULATION 10/25/2024 APPROVED BTAYLOR
Note: Inspector Notes from Inspection 2320 *** NOTES ADDED BY RSIMS 9/23/2024 2:22:20 PM *** 9/23/24: Window Nailing Inspection added for the interior garage doors that were not installed as of Lath/Brick/Water Barrier Inspection. Will need to be complete before scheduling Building Final Inspection. Inspector Notes from Inspection 2490 08-20-2024 Garage entry doors not installed. Please do not install casings on doors prior to final. The insulation in the jambs needs to be inspected. Also, proper nailing needs to be inspected. Inspector Notes from Inspection 2490 08-20-2024 Garage entry doors not installed. Please do not install casings on doors prior to final. The insulation in the jambs needs to be inspected. Also, proper nailing needs to be inspected.
ROW - DRAINAGE 10/18/2024 APPROVED - AS NOTED FSLADISH
Note: 10/17/24 I AM APPROVING THIS AS NOTED THAT YOU WILL MAINTAIN THE SWALE TO KEEP IT OPEN, FLOWING AND FREE FROM OBSTRUCTION AS REQUIRED. _______________________________________________________________________________________________________________________ 10/14/2024 - PREVIOUS INSPECTION NOTES 10/14/24 I HAVE READ YOUR NOTE AND WILL PARTIALLY APPROVE YOUR DRAINAGE AT THIS TIME. MAKE SURE THAT YOU KEEP THE SWALE OPEN AND FLOWING. I WILL REINSPECT ON 10/18/24 TO MAKE SURE IT IS STILL FLOWING WITHOUT OBSRTUCTION. __________________________________________________________________________________________________________________________ 10/7/2024 - PREVIOUS INSPECTION NOTES 10/7/24 YOU WILL NEED TO INSTALL A MINIMUM 12" DIAMETER TEMPORARY CULVERT PIPE AND/ OR KEEP YOUR SWALE GRADED DAILY OR A NECCESSARY TO MAINTIAN POSITIVE SWALE DRAINAGE FLOW. YOU NEED TO REMOVE PORTA POTTY FROM ROW AND PUT IT ON YOUR SITE. I WILL BE BACK FOR COMPLIANCE REINSPECTION ON 10/11/24.
ROW - DRAINAGE 10/11/2024 PARTIALLY APPROVED FSLADISH
Note: 10/14/24 I HAVE READ YOUR NOTE AND WILL PARTIALLY APPROVE YOUR DRAINAGE AT THIS TIME. MAKE SURE THAT YOU KEEP THE SWALE OPEN AND FLOWING. I WILL REINSPECT ON 10/18/24 TO MAKE SURE IT IS STILL FLOWING WITHOUT OBSRTUCTION. __________________________________________________________________________________________________________________________ 10/7/2024 - PREVIOUS INSPECTION NOTES 10/7/24 YOU WILL NEED TO INSTALL A MINIMUM 12" DIAMETER TEMPORARY CULVERT PIPE AND/ OR KEEP YOUR SWALE GRADED DAILY OR A NECCESSARY TO MAINTIAN POSITIVE SWALE DRAINAGE FLOW. YOU NEED TO REMOVE PORTA POTTY FROM ROW AND PUT IT ON YOUR SITE. I WILL BE BACK FOR COMPLIANCE REINSPECTION ON 10/11/24.
ROW - DRAINAGE 10/07/2024 Disapproved - NO FEE FSLADISH
Note: 10/7/24 YOU WILL NEED TO INSTALL A MINIMUM 12" DIAMETER TEMPORARY CULVERT PIPE AND/ OR KEEP YOUR SWALE GRADED DAILY OR A NECCESSARY TO MAINTIAN POSITIVE SWALE DRAINAGE FLOW. YOU NEED TO REMOVE PORTA POTTY FROM ROW AND PUT IT ON YOUR SITE. I WILL BE BACK FOR COMPLIANCE REINSPECTION ON 10/11/24.
PEP TANK INSTALLATION REQUEST 10/04/2024 Disapproved -FEE REQUIRED CBOWERMASTER
Note: temp power pole in the way
LATH/BRICK/ WATER BARRIER 09/23/2024 APPROVED - AS NOTED RSIMS
Note: *** NOTES ADDED BY RSIMS 9/23/2024 2:22:20 PM *** 9/23/24: Window Nailing Inspection added for the interior garage doors that were not installed as of Lath/Brick/Water Barrier Inspection. Will need to be complete before scheduling Building Final Inspection. Inspector Notes from Inspection 2490 08-20-2024 Garage entry doors not installed. Please do not install casings on doors prior to final. The insulation in the jambs needs to be inspected. Also, proper nailing needs to be inspected. Inspector Notes from Inspection 2490 08-20-2024 Garage entry doors not installed. Please do not install casings on doors prior to final. The insulation in the jambs needs to be inspected. Also, proper nailing needs to be inspected.
INSULATION 08/20/2024 APPROVED - AS NOTED AGAETANO
Note: 08-20-2024 Garage entry doors not installed. Please do not install casings on doors prior to final. The insulation in the jambs needs to be inspected. Also, proper nailing needs to be inspected.
WALL SHEATHING 08/19/2024 APPROVED BTAYLOR
Note: Inspector Notes from Inspection 2420 08-15-2024 Firewall penetrations not sealed. Check at insulation inspection.
ALL ROUGH 08/15/2024 APPROVED - AS NOTED AGAETANO
Note: 08-15-2024 Firewall penetrations not sealed. Check at insulation inspection.
ALL ROUGH 08/14/2024 CANCELLED BY APPLICANT WEB
FIREWALL FINAL 08/05/2024 APPROVED RSIMS
Note: 8/2/2024 - PREVIOUS INSPECTION NOTES 8/2/24: Incomplete Inspection. 1). No plans in box for inspection. FBC 107.3.1
FIREWALL FINAL 08/02/2024 Disapproved -FEE REQUIRED RSIMS
Note: 8/2/24: Incomplete Inspection. 1). No plans in box for inspection. FBC 107.3.1
FIREWALL DRYWALL NAILING 07/30/2024 APPROVED AGAETANO
ROOF VALLEY & METAL 07/25/2024 APPROVED AGAETANO
FIREWALL FRAMING 07/19/2024 APPROVED AGAETANO
Note: Inspector Notes from Inspection 2460 7/2/2024 - PREVIOUS INSPECTION NOTES 7/2/24: Not Ready. Framers still working on truss engineering (bracing). ** Roof Sheathing & down Cell (only) checked and approved. Partial list only due to not being fully ready for inspection: 1). Entire site needs overgrowth removed to make site safe for inspections. 2). Over framing is missing hold down straps as required. 07-08-2024 Sheet 5 detail 5 Wall section indicates 2 x 4 wall on each side of truss. 2 X 4 not installed per plan. Please install per plan or submit a revision to the building department for review and have approved on site. Contractor can proceed at own risk.
ROOF SHEATHING / BRACES/TIES/DOWN CELL 07/08/2024 APPROVED - AS NOTED AGAETANO
Note: 7/2/2024 - PREVIOUS INSPECTION NOTES 7/2/24: Not Ready. Framers still working on truss engineering (bracing). ** Roof Sheathing & down Cell (only) checked and approved. Partial list only due to not being fully ready for inspection: 1). Entire site needs overgrowth removed to make site safe for inspections. 2). Over framing is missing hold down straps as required. 07-08-2024 Sheet 5 detail 5 Wall section indicates 2 x 4 wall on each side of truss. 2 X 4 not installed per plan. Please install per plan or submit a revision to the building department for review and have approved on site. Contractor can proceed at own risk.
ROOF SHEATHING / BRACES/TIES/DOWN CELL 07/02/2024 Disapproved - NO FEE RSIMS
Note: 7/2/24: Not Ready. Framers still working on truss engineering (bracing). ** Roof Sheathing & down Cell (only) checked and approved. Partial list only due to not being fully ready for inspection: 1). Entire site needs overgrowth removed to make site safe for inspections. 2). Over framing is missing hold down straps as required.
FIREWALL DRYWALL NAILING 07/01/2024 CANCELLED BY APPLICANT WEB
ELECTRIC TEMP POLE 05/22/2024 APPROVED - AS NOTED RSIMS
Note: 5/22/24: FPL emailed at @ 14:45. Approved for Temporaray Pole power. 5/14/2024 - PREVIOUS INSPECTION NOTES 5/14/24: 1). Silt fence is incomplete and damaged. 3 sides minimum required. FBC 3307.1 (3307.1Protection required. Adjoining public and private property shall be protected from damage during construction, remodeling and demolition work.) 2). Need overgrowth throughout entire site along with, trash & debris removed to make site safe for inspections. 3). Dumpster required throughout build per City requirements. 4). Need a portable toilet on site throughout build. TOILET FACILITIES FOR WORKERS 311.1 General. Toilet facilities shall be provided for construction workers and such facilities shall be maintained in a sanitary condition. Construction worker toilet facilities of the nonsewer type shall conform to ANSI Z4.3.
ELECTRIC TEMP POLE 05/14/2024 Disapproved -FEE REQUIRED RSIMS
Note: 5/14/24: 1). Silt fence is incomplete and damaged. 3 sides minimum required. FBC 3307.1 (3307.1Protection required. Adjoining public and private property shall be protected from damage during construction, remodeling and demolition work.) 2). Need overgrowth throughout entire site along with, trash & debris removed to make site safe for inspections. 3). Dumpster required throughout build per City requirements. 4). Need a portable toilet on site throughout build. TOILET FACILITIES FOR WORKERS 311.1 General. Toilet facilities shall be provided for construction workers and such facilities shall be maintained in a sanitary condition. Construction worker toilet facilities of the nonsewer type shall conform to ANSI Z4.3.
TIE DOWN 11/30/2023 APPROVED JWALKER
Note: Tie beam, and lintel approved 6/22/23.
TIE BEAM / LINTEL 06/22/2023 APPROVED KSANDOE
FOUND SURVEY APPROVED (OFFICE) 05/17/2023 APPROVED TBAKER
MONOLITHIC SLAB 05/04/2023 APPROVED RSIMS
Note: 5/3/2023 - PREVIOUS INSPECTION NOTES 5/3/23: Still need relieving arches or sleeves where water lines cross through/over the footer as previously noted. 5/1/2023 - PREVIOUS INSPECTION NOTES Pressure low on PVC supply lines Where pipes pass through footings, there must be releiving arches or the pipes must be sleeved Due to rain, a few locations have washed in not allowing for the 3" distance from soil to rebar
MONOLITHIC SLAB 05/03/2023 Disapproved -FEE REQUIRED RSIMS
Note: 5/3/23: Still need relieving arches or sleeves where water lines cross through/over the footer as previously noted. 5/1/2023 - PREVIOUS INSPECTION NOTES Pressure low on PVC supply lines Where pipes pass through footings, there must be releiving arches or the pipes must be sleeved Due to rain, a few locations have washed in not allowing for the 3" distance from soil to rebar
MONOLITHIC SLAB 05/01/2023 Disapproved - NO FEE TSTAUFFACHER
Note: Pressure low on PVC supply lines Where pipes pass through footings, there must be releiving arches or the pipes must be sleeved Due to rain, a few locations have washed in not allowing for the 3" distance from soil to rebar
PLUMBING 1ST ROUGH UNDERGROUND 04/28/2023 APPROVED - AS NOTED MGIBSON
Note: 4/25/2023 - PREVIOUS INSPECTION NOTES GOLDEN MAGNOILIA CALLED AND CANCELLED HAVE PORTABLE RESTROOM BY NEXT INSPECTION
PLUMBING 1ST ROUGH UNDERGROUND 04/25/2023 CANCELLED BY APPLICANT MGIBSON
Note: GOLDEN MAGNOILIA CALLED AND CANCELLED
WATER METER INSTALLATION REQUEST 04/14/2023 APPROVED CSTONE

Review History

Department Status Date In Date Out
MECH COMPLETE 02/04/2025 02/07/2025
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
BLD COMPLETE 07/11/2024 07/18/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
BADMIN INFORMATION 11/27/2023 11/27/2023
Note: Marked INFORMATION By: BARBIE BEMBRY - (386)986-3780 - BUILDINGDIVISION@PALMCOASTGOV.COM Permit extension denied. A valid reason justifying an extension has not been provided. Patrick Buckley Chief Building Official
ENGIN1 COMPLETE 05/17/2023 05/17/2023
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON COMPLETE 05/17/2023 05/17/2023
Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM
ELEC COMPLETE 11/01/2022 11/02/2022
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
MECH COMPLETE 11/01/2022 11/02/2022
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
BLD COMPLETE 11/01/2022 11/03/2022
Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM
CUSVC COMPLETE 11/01/2022 11/04/2022
Note: Released By: LISA ASBILL - - lasbill@palmcoastgov.com
ZON COMPLETE 11/01/2022 11/01/2022
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
CUSVC COMPLETE 10/12/2022 10/12/2022
Note: Released By: CYNTHIA SCHWEERS - - CSCHWEERS@PALMCOASSTGOV.COM
SWALE COMPLETE 10/07/2022 02/17/2023
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
BLD HOLD 10/06/2022 10/11/2022
Note: Held By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM All comments below per the 2020 Florida Building Code-Building PLAN REVIEW COMMENTS: 1. Note on Sheet 1 calls-out, the proposed is located within a wind-Borne Debris Region and all the exterior glazing shall be protected. Product approvals submitted are for non-impact rated glazing. A revision to the note or product approval I required.
CUSVC HOLD 10/06/2022 10/07/2022
Note: Held By: HALEIGH HAND - - Please correct the utility application to reflect duplex instead of single family.
ELEC HOLD 10/06/2022 10/06/2022
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Submit electric load calcs. 2. Need correct outlet spacing in all bedrooms. NEC 2017 210.52
ENGIN1 COMPLETE 10/06/2022 10/07/2022
Note: Released By: JOHN HOWARD - - JHOWARD@PALMCOASTGOV.COM
LOCATE COMPLETE 10/06/2022 10/11/2022
Note: Released By: CANDACE STONE - - CSTONE@PALMCOASTGOV.COM
MECH HOLD 10/06/2022 10/06/2022
Note: Held By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM Energy Calcs need to be signed by the builder per 107.1 FBC Residential 2020 7th edition
SW1 COMPLETE 10/06/2022 10/10/2022
Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM
ZON COMPLETE 10/06/2022 10/07/2022
Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
PLAN REVIEW - REVISION ¤32.50 02/10/2025
REINSPECTION RESIDENTIAL ¤40.00 02/06/2025
REINSPECTION RESIDENTIAL ¤40.00 02/06/2025
PLAN REVIEW - REVISION ¤32.50 02/06/2025
SW ENG - INSPECTION 20 ¤20.00 02/06/2025
SW ENG - INSPECTION 20 ¤20.00 02/06/2025
SW ENG - INSPECTION 20 ¤20.00 02/06/2025
UTILITY PEP REINSPECTION ¤40.00 02/06/2025
REINSPECTION RESIDENTIAL ¤40.00 06/28/2024
CONTRACTOR CHANGE ¤20.00 04/24/2024
CONTRACTOR CHANGE ¤20.00 04/24/2024
REINSPECTION RESIDENTIAL ¤40.00 04/24/2024
CONNECTION FEES ¤2,332.52 04/06/2023
FIRE IMPACT FEE ADMIN (¤25.23) 04/06/2023
FIRE IMPACT FEE ADMIN ¤25.23 04/06/2023
IMPACT FEE FIRE ¤841.04 04/06/2023
PLAN REVIEW - RESIDENTIAL ¤335.40 04/06/2023
ADJUSTMENT 50% (¤773.95) 04/06/2023
INSPECTION - RESIDENTIAL ¤1,182.50 04/06/2023
WATER- TURN ON ¤50.00 04/06/2023
ADMINISTRATIVE RESIDENTIAL ¤30.00 04/06/2023
SW ENG INSPECTION 80 ¤80.00 04/06/2023
PARKS IMPACT FEE ADMIN ¤106.15 04/06/2023
SURCHARGE FS 533.721 ¤4.81 04/06/2023
SURCHARGE - FS 468.631 ¤7.21 04/06/2023
IMPACT FEE PARKS ¤3,538.30 04/06/2023
IMPACT FEE TRANSPORTATION ¤2,738.00 04/06/2023
IMPACT FEE SCHOOL ¤10,900.00 04/06/2023
WATER -IRRIGATION INSPECTION ¤50.00 04/06/2023
PARKS IMPACT FEE ADMIN (¤106.15) 04/06/2023
SW ENG - FOUNDATION SURVEY ¤20.00 04/06/2023
TRANS IMPACT FEE ADMIN (¤82.14) 04/06/2023
SW ENG PRE APRON ¤30.00 04/06/2023
TRANS IMPACT FEE ADMIN ¤82.14 04/06/2023
SW ENG - REVIEW 20 ¤20.00 04/06/2023
SW ENG RES REVIEW 200 ¤200.00 04/06/2023
SEWER CREDIT (¤2,932.00) 04/06/2023
SEWER INSPECTION ¤25.00 04/06/2023
SEWER CAPITAL FACILITY ¤10,689.64 04/06/2023
WATER CAPITAL FACILITY FEE ¤7,847.76 04/06/2023
SITE PLAN 30 ¤30.00 04/06/2023
WATER CAPITAL FACILITY FEE ¤7,847.76 02/27/2023
SITE PLAN 30 ¤30.00 02/27/2023
SITE PLAN 30 (¤30.00) 02/27/2023
WATER CAPITAL FACILITY FEE (¤7,847.76) 02/27/2023
SEWER CAPITAL FACILITY ¤10,689.64 02/27/2023
SEWER CAPITAL FACILITY (¤10,689.64) 02/27/2023
SEWER CREDIT (¤2,932.00) 02/27/2023
SEWER INSPECTION ¤25.00 02/27/2023
SEWER INSPECTION (¤25.00) 02/27/2023
TRANS IMPACT FEE ADMIN ¤82.14 02/27/2023
TRANS IMPACT FEE ADMIN (¤82.14) 02/27/2023
TRANS IMPACT FEE ADMIN (¤82.14) 02/27/2023
SW ENG - REVIEW 20 ¤20.00 02/27/2023
SW ENG RES REVIEW 200 ¤200.00 02/27/2023
SW ENG RES REVIEW 200 (¤200.00) 02/27/2023
TRANS IMPACT FEE ADMIN ¤82.14 02/27/2023
SW ENG - REVIEW 20 (¤20.00) 02/27/2023
SEWER CREDIT ¤2,932.00 02/27/2023
PARKS IMPACT FEE ADMIN ¤106.15 02/27/2023
PARKS IMPACT FEE ADMIN (¤106.15) 02/27/2023
SURCHARGE FS 533.721 ¤4.81 02/27/2023
SURCHARGE FS 533.721 (¤4.81) 02/27/2023
PARKS IMPACT FEE ADMIN (¤106.15) 02/27/2023
IMPACT FEE TRANSPORTATION (¤2,738.00) 02/27/2023
IMPACT FEE TRANSPORTATION ¤2,738.00 02/27/2023
WATER -IRRIGATION INSPECTION ¤50.00 02/27/2023
WATER -IRRIGATION INSPECTION (¤50.00) 02/27/2023
IMPACT FEE PARKS ¤3,538.30 02/27/2023
IMPACT FEE SCHOOL ¤10,900.00 02/27/2023
IMPACT FEE SCHOOL (¤10,900.00) 02/27/2023
SURCHARGE - FS 468.631 ¤7.21 02/27/2023
SW ENG - FOUNDATION SURVEY ¤20.00 02/27/2023
SW ENG - FOUNDATION SURVEY (¤20.00) 02/27/2023
SURCHARGE - FS 468.631 (¤7.21) 02/27/2023
PARKS IMPACT FEE ADMIN ¤106.15 02/27/2023
SW ENG INSPECTION 80 ¤80.00 02/27/2023
SW ENG PRE APRON ¤30.00 02/27/2023
SW ENG PRE APRON (¤30.00) 02/27/2023
SW ENG INSPECTION 80 (¤80.00) 02/27/2023
ADMINISTRATIVE RESIDENTIAL ¤30.00 02/27/2023
INSPECTION - RESIDENTIAL ¤1,182.50 02/27/2023
INSPECTION - RESIDENTIAL (¤1,182.50) 02/27/2023
ADJUSTMENT 50% (¤773.95) 02/27/2023
ADJUSTMENT 50% ¤773.95 02/27/2023
WATER- TURN ON ¤50.00 02/27/2023
WATER- TURN ON (¤50.00) 02/27/2023
PLAN REVIEW - RESIDENTIAL (¤335.40) 02/27/2023
ADMINISTRATIVE RESIDENTIAL (¤30.00) 02/27/2023
PLAN REVIEW - RESIDENTIAL ¤335.40 02/27/2023
IMPACT FEE PARKS (¤3,538.30) 02/27/2023
FIRE IMPACT FEE ADMIN ¤25.23 02/27/2023
FIRE IMPACT FEE ADMIN ¤25.23 02/27/2023
FIRE IMPACT FEE ADMIN (¤25.23) 02/27/2023
IMPACT FEE FIRE ¤841.04 02/27/2023
IMPACT FEE FIRE (¤841.04) 02/27/2023
FIRE IMPACT FEE ADMIN (¤25.23) 02/27/2023
CONNECTION FEES ¤2,332.52 02/27/2023
CONNECTION FEES (¤2,332.52) 02/27/2023
Fees Total Due: ¤0.00 Total Paid: ¤37,611.23