I want to search for...

Permit #2022100442

Permit Details

Status: COED

Parcel Id: 07-11-31-7034-00940-0070
CONDITIONED SPACE: 2548 sqft
GARAGE: 537 sqft
OPENED PORCH (WITH ROOF) : 61 sqft
OPENED PORCH (WITH ROOF) : 401 sqft
Total Square Footage: 3547 sqft
Block: 00940
Subdivision: 2165 - SECTION 34-EASTHAMPTON
Job Phone: 386-237-1210
Location Address: 11 ETHAN ALLEN DR
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 05/01/2023
NOC: RECORDED
Applicant name: ANDREW POPOV
Owner: RYUMA DMITRY

Address

14004 PALAWAN WAY PH05

MARINA DEL REY, CA 90292

Lot: 0070
Contracted Stated Job Value: ¤350,000.00
Job Description: Single family Residence
Type: CN

Contractor

SILVER BREEZE HOMES
Status Location Address State License Number Phone
ACTIVE

1 SEATHORN PATH UNIT A

PALM COAST, FL 32164

RR282812121 (Exp: 08/31/2027) 386-237-7700

Sub Contractors

GARY LLOYD SHEFFIELD
Status Location Address State License Number Phone
ACTIVE

48 EAGLE LAKES DRIVE

FLAGLER BEACH, FL 32136

CAC048127 (Exp: 08/31/2026) 386-597-3280
HEATH EDWARD SANFORD
Status Location Address State License Number Phone
ACTIVE

126 EAST END RD

SAN MATEO, FL 32187

CFC1429896 (Exp: 08/31/2026) 386-871-8823
MAXIM BUDNIK
Status Location Address State License Number Phone
ACTIVE

9788 HALSEY RD

JACKSONVILLE, FL 32246

EC13007415 (Exp: 08/31/2026) 904-509-7306
OLEG BELINSKIY
Status Location Address State License Number Phone
ACTIVE

19 PINE CIRCLE DRIVE19

PALM COAST, FL 32167

CCC1325974 (Exp: 08/31/2026) 386-263-7906

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 07/19/2024 FINAL APPROVED AGAETANO
Note: 7/18/2024 - PREVIOUS INSPECTION NOTES 7/18/24: 1). AHU is missing the heater core label FBC-M1303.1 & breaker panel needs to be labeled that the AHU is in the attic. M1401.1 2). Outside Condensing unit breaker is too small. (Min 32.8amp / Max 50amp - 30amp installed). 3). 1 of 3 laundry rm. outlets is not GFCI as required. (right side lower outlet). E3902.9 - Laundry Areas 4). Kitchen outlet on right wall (to right of island) is not GFCI protected. E3902.6 - Kitchen 5). Hole cut in attic insulation for new duct location needs to be sealed around the perimeter & at any gaps created. FBCEC R402.4 6). Holes in garage wall & at ceiling for lineset sleeve need to be sealed. FBC R302.6 7/17/2024 - PREVIOUS INSPECTION NOTES Swale area at vacant property on the right will need to have damage repaired from dumpster, etc as identified during inspection 2460 on 8/22/23. This house has spray foam insulation in the attic that was inspected & approved during Insulation Inspection.
BLD - BUILDING FINAL 07/18/2024 Disapproved -FEE REQUIRED RSIMS
Note: 7/18/24: 1). AHU is missing the heater core label FBC-M1303.1 & breaker panel needs to be labeled that the AHU is in the attic. M1401.1 2). Outside Condensing unit breaker is too small. (Min 32.8amp / Max 50amp - 30amp installed). 3). 1 of 3 laundry rm. outlets is not GFCI as required. (right side lower outlet). E3902.9 - Laundry Areas 4). Kitchen outlet on right wall (to right of island) is not GFCI protected. E3902.6 - Kitchen 5). Hole cut in attic insulation for new duct location needs to be sealed around the perimeter & at any gaps created. FBCEC R402.4 6). Holes in garage wall & at ceiling for lineset sleeve need to be sealed. FBC R302.6 7/17/2024 - PREVIOUS INSPECTION NOTES Swale area at vacant property on the right will need to have damage repaired from dumpster, etc as identified during inspection 2460 on 8/22/23. This house has spray foam insulation in the attic that was inspected & approved during Insulation Inspection.
BLD - BUILDING FINAL 07/17/2024 CANCELLED BY APPLICANT AGAETANO
Note: Swale area at vacant property on the right will need to have damage repaired from dumpster, etc as identified during inspection 2460 on 8/22/23. This house has spray foam insulation in the attic that was inspected & approved during Insulation Inspection.
ROW - STORMWATER FINAL 04/15/2024 APPROVED TPOLACEK
Note: 04/15/24 CORRECTIONS HAVE BEEN MADE SEED N STRAW ARE DOWN AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED -------------------------------------------------------------------------------------------------------------------- 3/26/2024 - PREVIOUS INSPECTION NOTES 03/26/24 NEED TO SEED AND STRAW ALL BARE DISTURBED GROUNF IN VACANT LOT TO THE RIGHT SIDE OF THE PROPERTY. INCLUDING AREA WHERE DIRT WAS DUMPED AND SPREAD.
ROW - STORMWATER FINAL 03/26/2024 Disapproved - NO FEE TPOLACEK
Note: 03/26/24 NEED TO SEED AND STRAW ALL BARE DISTURBED GROUNF IN VACANT LOT TO THE RIGHT SIDE OF THE PROPERTY. INCLUDING AREA WHERE DIRT WAS DUMPED AND SPREAD.
ROW - FINAL APRON (AFTER POUR) 03/26/2024 APPROVED TPOLACEK
Note: 03/26/24 PIPES IS GOOD, CUTS ARE MADE, CULVERT CLEAR, HOT PATCH COMPLETE. AT THE TIME OF THE INSPECTION ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED
U-CROSS CONNECTION 03/06/2024 APPROVED - AS NOTED JHARDING
Note: No irrigation, no cross connections.
U -UTILITY RESIDENTIAL FINAL 03/06/2024 FINAL APPROVED JHARDING
ROW- FINAL SURVEY/GRADING CERTIFICATION 03/04/2024 APPROVED GBERTOLA
Note: AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. THIS INCLUDES BUT IS NOT LIMITED TO THE CULVERT PIPE ELEVATION APPROVAL FOR THE CONCRETE POUR.
ROW FIELD SURVEY /GRADING CERTIFICATION 03/04/2024 APPROVED GBERTOLA
Note: AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. THIS INCLUDES BUT IS NOT LIMITED TO THE CULVERT PIPE ELEVATION APPROVAL FOR THE CONCRETE POUR.
ELECTRIC - EARLY POWER 01/10/2024 APPROVED - AS NOTED RSIMS
Note: 1/10/24: FPL emailed to release power. * FBC 3307.1 You will need to have your silt fence barrier repaired & keep it maintained in original condition per FBC 3307.1 to avoid disapproved inspections with fee going forward. This must be complete prior to the next inspection. Inspector Notes from Inspection 2170 9/12/23: FPL emailed to release power at @ 12:30.
GRAVITY SEWER TEST 12/19/2023 APPROVED MGIBSON
U - SEWER TIE IN 12/19/2023 APPROVED MGIBSON
ROW- PRE-APRON (PRE-POUR) 12/04/2023 APPROVED FSLADISH
Note: 12/4/23 ** READY TO POUR AT TIME OF INSPECTION PIPE IS WITHIN TOLERANCE AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved. This includes but is not limited to, the Culvert Pipe Elevation from the time of the inspection approval to the concrete pour
PEP TANK INSTALLATION REQUEST 12/04/2023 APPROVED CBOWERMASTER
LATH/BRICK/ WATER BARRIER 10/24/2023 APPROVED RSIMS
INSULATION 10/19/2023 APPROVED JWALKER
Note: 10/18/2023 - PREVIOUS INSPECTION NOTES 10/18/23: ** Missing firestop at top plate penetration in right side bathroom above tub faucet (FS written on stud) & right back bedroom. (FS written on wall). Inspector Notes from Inspection 2420 Nail plates needed to protect wire at the top plated of the garage wall. 3 locations. Next to entry door, at the panel wiring and the garage outlet 12-2 wire.
INSULATION 10/18/2023 Disapproved - NO FEE RSIMS
Note: 10/18/23: ** Missing firestop at top plate penetration in right side bathroom above tub faucet (FS written on stud) & right back bedroom. (FS written on wall). Inspector Notes from Inspection 2420 Nail plates needed to protect wire at the top plated of the garage wall. 3 locations. Next to entry door, at the panel wiring and the garage outlet 12-2 wire.
ALL ROUGH 10/09/2023 APPROVED - AS NOTED JWALKER
Note: Nail plates needed to protect wire at the top plated of the garage wall. 3 locations. Next to entry door, at the panel wiring and the garage outlet 12-2 wire.
ROOF VALLEY & METAL 09/20/2023 APPROVED RSIMS
Note: 9/19/2023 - PREVIOUS INSPECTION NOTES 9/19/23 the peel and stick can only be layed on wood not over the underlayment Florida Building Code 905.1.1.1(5) 9/18/2023 - PREVIOUS INSPECTION NOTES 9/15/2023 - PREVIOUS INSPECTION NOTES 9/15/23: No Change from previous inspection. 9/12/2023 - PREVIOUS INSPECTION NOTES 9/12/23: 1). Underlayment nailing pattern does not meet manufacturer's and/or Florida Building Code 905.1.1.1(5) minimum requirements. 2). 5" x 5" wall flashing on right side of entry is not sealed properly. Must be sealed to wall not water/vapor barrier. Inspector Notes from Inspection 2460 8/24/23: Approved as noted pending revision for the Truss 28 being submitted & approved by the City for the corrected truss configeration/engineering. This will require a letter from the MiTek/truss engineer. 8/22/2023 - PREVIOUS INSPECTION NOTES 8/22/23: Please remove dumpster from neighboring swale and have it placed on job site before next inspection. Also, please have portable toilet moved out of swale area. 1). Truss 07 & 08 are missing one piece of web bracing/engineering. Marked on MiTek. 2). Truss 28 does not match the configeration shown on MiTek & is therefore missing web bracing/engineering as required. A revision will need to be submitted to & approved by the City for this truss. Note: I found the MiTek packet laying in the dirt of the neighboring property. Please make sure that the documents are together for Inspections. 8/21/2023 - PREVIOUS INSPECTION NOTES 8/21/23: Cancelled by Applicant via text at @ 09:05. Stated not ready.
ROOF VALLEY & METAL 09/19/2023 Disapproved - NO FEE RMARTIN
Note: 9/19/23 the peel and stick can only be layed on wood not over the underlayment Florida Building Code 905.1.1.1(5) 9/18/2023 - PREVIOUS INSPECTION NOTES 9/15/2023 - PREVIOUS INSPECTION NOTES 9/15/23: No Change from previous inspection. 9/12/2023 - PREVIOUS INSPECTION NOTES 9/12/23: 1). Underlayment nailing pattern does not meet manufacturer's and/or Florida Building Code 905.1.1.1(5) minimum requirements. 2). 5" x 5" wall flashing on right side of entry is not sealed properly. Must be sealed to wall not water/vapor barrier. Inspector Notes from Inspection 2460 8/24/23: Approved as noted pending revision for the Truss 28 being submitted & approved by the City for the corrected truss configeration/engineering. This will require a letter from the MiTek/truss engineer. 8/22/2023 - PREVIOUS INSPECTION NOTES 8/22/23: Please remove dumpster from neighboring swale and have it placed on job site before next inspection. Also, please have portable toilet moved out of swale area. 1). Truss 07 & 08 are missing one piece of web bracing/engineering. Marked on MiTek. 2). Truss 28 does not match the configeration shown on MiTek & is therefore missing web bracing/engineering as required. A revision will need to be submitted to & approved by the City for this truss. Note: I found the MiTek packet laying in the dirt of the neighboring property. Please make sure that the documents are together for Inspections. 8/21/2023 - PREVIOUS INSPECTION NOTES 8/21/23: Cancelled by Applicant via text at @ 09:05. Stated not ready.
ROOF VALLEY & METAL 09/18/2023 CANCELLED BY APPLICANT BTAYLOR
Note: 9/15/2023 - PREVIOUS INSPECTION NOTES 9/15/23: No Change from previous inspection. 9/12/2023 - PREVIOUS INSPECTION NOTES 9/12/23: 1). Underlayment nailing pattern does not meet manufacturer's and/or Florida Building Code 905.1.1.1(5) minimum requirements. 2). 5" x 5" wall flashing on right side of entry is not sealed properly. Must be sealed to wall not water/vapor barrier. Inspector Notes from Inspection 2460 8/24/23: Approved as noted pending revision for the Truss 28 being submitted & approved by the City for the corrected truss configeration/engineering. This will require a letter from the MiTek/truss engineer. 8/22/2023 - PREVIOUS INSPECTION NOTES 8/22/23: Please remove dumpster from neighboring swale and have it placed on job site before next inspection. Also, please have portable toilet moved out of swale area. 1). Truss 07 & 08 are missing one piece of web bracing/engineering. Marked on MiTek. 2). Truss 28 does not match the configeration shown on MiTek & is therefore missing web bracing/engineering as required. A revision will need to be submitted to & approved by the City for this truss. Note: I found the MiTek packet laying in the dirt of the neighboring property. Please make sure that the documents are together for Inspections. 8/21/2023 - PREVIOUS INSPECTION NOTES 8/21/23: Cancelled by Applicant via text at @ 09:05. Stated not ready.
ROOF VALLEY & METAL 09/15/2023 Disapproved -FEE REQUIRED RSIMS
Note: 9/15/23: No Change from previous inspection. 9/12/2023 - PREVIOUS INSPECTION NOTES 9/12/23: 1). Underlayment nailing pattern does not meet manufacturer's and/or Florida Building Code 905.1.1.1(5) minimum requirements. 2). 5" x 5" wall flashing on right side of entry is not sealed properly. Must be sealed to wall not water/vapor barrier. Inspector Notes from Inspection 2460 8/24/23: Approved as noted pending revision for the Truss 28 being submitted & approved by the City for the corrected truss configeration/engineering. This will require a letter from the MiTek/truss engineer. 8/22/2023 - PREVIOUS INSPECTION NOTES 8/22/23: Please remove dumpster from neighboring swale and have it placed on job site before next inspection. Also, please have portable toilet moved out of swale area. 1). Truss 07 & 08 are missing one piece of web bracing/engineering. Marked on MiTek. 2). Truss 28 does not match the configeration shown on MiTek & is therefore missing web bracing/engineering as required. A revision will need to be submitted to & approved by the City for this truss. Note: I found the MiTek packet laying in the dirt of the neighboring property. Please make sure that the documents are together for Inspections. 8/21/2023 - PREVIOUS INSPECTION NOTES 8/21/23: Cancelled by Applicant via text at @ 09:05. Stated not ready.
ROOF VALLEY & METAL 09/12/2023 Disapproved - NO FEE RSIMS
Note: 9/12/23: 1). Underlayment nailing pattern does not meet manufacturer's and/or Florida Building Code 905.1.1.1(5) minimum requirements. 2). 5" x 5" wall flashing on right side of entry is not sealed properly. Must be sealed to wall not water/vapor barrier. Inspector Notes from Inspection 2460 8/24/23: Approved as noted pending revision for the Truss 28 being submitted & approved by the City for the corrected truss configeration/engineering. This will require a letter from the MiTek/truss engineer. 8/22/2023 - PREVIOUS INSPECTION NOTES 8/22/23: Please remove dumpster from neighboring swale and have it placed on job site before next inspection. Also, please have portable toilet moved out of swale area. 1). Truss 07 & 08 are missing one piece of web bracing/engineering. Marked on MiTek. 2). Truss 28 does not match the configeration shown on MiTek & is therefore missing web bracing/engineering as required. A revision will need to be submitted to & approved by the City for this truss. Note: I found the MiTek packet laying in the dirt of the neighboring property. Please make sure that the documents are together for Inspections. 8/21/2023 - PREVIOUS INSPECTION NOTES 8/21/23: Cancelled by Applicant via text at @ 09:05. Stated not ready.
ELECTRIC TEMP POLE 09/12/2023 APPROVED - AS NOTED RSIMS
Note: 9/12/23: FPL emailed to release power at @ 12:30.
ROOF SHEATHING / BRACES/TIES/DOWN CELL 08/24/2023 APPROVED - AS NOTED RSIMS
Note: 8/24/23: Approved as noted pending revision for the Truss 28 being submitted & approved by the City for the corrected truss configeration/engineering. This will require a letter from the MiTek/truss engineer. 8/22/2023 - PREVIOUS INSPECTION NOTES 8/22/23: Please remove dumpster from neighboring swale and have it placed on job site before next inspection. Also, please have portable toilet moved out of swale area. 1). Truss 07 & 08 are missing one piece of web bracing/engineering. Marked on MiTek. 2). Truss 28 does not match the configeration shown on MiTek & is therefore missing web bracing/engineering as required. A revision will need to be submitted to & approved by the City for this truss. Note: I found the MiTek packet laying in the dirt of the neighboring property. Please make sure that the documents are together for Inspections. 8/21/2023 - PREVIOUS INSPECTION NOTES 8/21/23: Cancelled by Applicant via text at @ 09:05. Stated not ready.
ROOF SHEATHING / BRACES/TIES/DOWN CELL 08/22/2023 Disapproved - NO FEE RSIMS
Note: 8/22/23: Please remove dumpster from neighboring swale and have it placed on job site before next inspection. Also, please have portable toilet moved out of swale area. 1). Truss 07 & 08 are missing one piece of web bracing/engineering. Marked on MiTek. 2). Truss 28 does not match the configeration shown on MiTek & is therefore missing web bracing/engineering as required. A revision will need to be submitted to & approved by the City for this truss. Note: I found the MiTek packet laying in the dirt of the neighboring property. Please make sure that the documents are together for Inspections. 8/21/2023 - PREVIOUS INSPECTION NOTES 8/21/23: Cancelled by Applicant via text at @ 09:05. Stated not ready.
WALL SHEATHING 08/22/2023 APPROVED RSIMS
Note: 8/21/2023 - PREVIOUS INSPECTION NOTES 8/21/23: Cancelled by Applicant via text at @ 09:05. Stated not ready.
ROOF SHEATHING / BRACES/TIES/DOWN CELL 08/21/2023 CANCELLED BY APPLICANT RSIMS
Note: 8/21/23: Cancelled by Applicant via text at @ 09:05. Stated not ready.
WALL SHEATHING 08/21/2023 CANCELLED BY APPLICANT RSIMS
Note: 8/21/23: Cancelled by Applicant via text at @ 09:05. Stated not ready.
TIE BEAM / LINTEL 07/24/2023 APPROVED MKRASKI
FOUND SURVEY APPROVED (OFFICE) 06/29/2023 APPROVED TBAKER
MONOLITHIC SLAB 06/14/2023 APPROVED RSIMS
PLUMBING 1ST ROUGH UNDERGROUND 06/12/2023 APPROVED MGIBSON
WATER METER INSTALLATION REQUEST 05/12/2023 APPROVED CSTONE
Note: 5/11/2023 8:18:56 AM- PREVIOUS INSPECTION NOTES not cleared
WATER METER INSTALLATION REQUEST 05/10/2023 Disapproved - NO FEE CSTONE
Note: not cleared

Review History

Department Status Date In Date Out
MECH COMPLETE 01/12/2024 01/16/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
MECH HOLD 01/10/2024 01/12/2024
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Energy Calcs need to be signed by the owner/ owner agent below the preparer per R103.1.1.2 FBC Energy Conservation 2023 8Th edition
BLD COMPLETE 08/24/2023 08/28/2023
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
ENGIN1 COMPLETE 06/29/2023 06/29/2023
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON COMPLETE 06/29/2023 06/29/2023
Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM
SW1 COMPLETE 05/23/2023 05/23/2023
Note: Released By: GABRIEL BERTOLA - (386)986-7660 - GBERTOLA@PALMCOASTGOV.COM
ZON COMPLETE 05/17/2023 05/18/2023
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
ENGIN1 COMPLETE 05/17/2023 05/18/2023
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
SW1 COMPLETE 11/03/2022 11/04/2022
Note: Released By: GABRIEL BERTOLA - (386)986-7660 - GBERTOLA@PALMCOASTGOV.COM
ENGIN1 COMPLETE 11/03/2022 11/03/2022
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON COMPLETE 11/03/2022 11/03/2022
Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM
ENGIN1 COMPLETE 11/02/2022 11/02/2022
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
SW1 HOLD 11/02/2022 11/02/2022
Note: Held By: GABRIEL BERTOLA - (386)986-7660 - GBERTOLA@PALMCOASTGOV.COM NEED TO MAKE A COMMON SWALE ON THE LEFT PROPERTY
ZON COMPLETE 11/02/2022 11/02/2022
Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM
ZON HOLD 10/26/2022 10/26/2022
Note: Held By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM REPEAT COMMENT: THE RIGHT SIDEOF THE ORIGINAL DRIVEWAY IS NOT AT 18 THAT IS YOUR WIDEST POINT PLEASE FIX IT. Circular driveways to have a circular shape. The maximum width of the circular driveway may not exceed 18 feet at it's widest point and site plan must demonstrate this. Please provide setback from front property line to bottom arc of circular driveway to demonstrate it meets 5' minimum required setback Driveway width exceeds the allowed width of 36' for a 2 car garage. Please adjust plans accordingly.
ENGIN1 COMPLETE 10/26/2022 10/26/2022
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
SW1 COMPLETE 10/26/2022 11/02/2022
Note: Released By: GABRIEL BERTOLA - (386)986-7660 - GBERTOLA@PALMCOASTGOV.COM
ZON HOLD 10/18/2022 10/19/2022
Note: Held By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM Circular driveways to have a circular shape. The maximum width of the circular driveway may not exceed 18 feet at it's widest point and site plan must demonstrate this. Please provide setback from front property line to bottom arc of circular driveway to demonstrate it meets 5' minimum required setback Driveway width exceeds the allowed width of 36' for a 2 car garage. Please adjust plans accordingly.
BLD COMPLETE 10/18/2022 10/24/2022
Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM
SW1 COMPLETE 10/18/2022 10/25/2022
Note: Released By: ROBERT GROSS - (386)986-4769 - RGROSS@PALMCOASTGOV.COM
ENGIN1 COMPLETE 10/18/2022 10/19/2022
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
BLD HOLD 10/10/2022 10/12/2022
Note: Held By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM All comments below per the 2020 Florida Building Code PLAN REVIEW COMMENTS: Repeat Comments 1. Design pressures on Sheet C-1 to be revised for the correct roof slope.
CUSVC COMPLETE 10/10/2022 10/11/2022
Note: Released By: CYNTHIA SCHWEERS - - CSCHWEERS@PALMCOASSTGOV.COM
ELEC COMPLETE 10/10/2022 10/10/2022
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ENGIN1 COMPLETE 10/10/2022 10/10/2022
Note: Released By: JOHN HOWARD - - JHOWARD@PALMCOASTGOV.COM
LOCATE COMPLETE 10/10/2022 10/14/2022
Note: Released By: CANDACE STONE - - CSTONE@PALMCOASTGOV.COM
MECH COMPLETE 10/10/2022 10/11/2022
Note: Released By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM
SW1 HOLD 10/10/2022 10/18/2022
Note: Held By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM NEED TO MAKE A COMMON SWALE ON THE LEFT PROPERTY
ZON HOLD 10/10/2022 10/12/2022
Note: Held By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM Site plan: Circular driveways to have a circular shape. The maximum width of the circular driveway may not exceed 18 feet at it's widest point and site plan must demonstrate this. Please provide setback from front property line to bottom arc of circular driveway to demonstrate it meets 5' minimum required setback
SWALE COMPLETE 10/10/2022 02/23/2023
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
PLAN REVIEW - REVISION ¤32.50 07/19/2024
PLAN REVIEW - REVISION ¤32.50 07/19/2024
REINSPECTION RESIDENTIAL ¤40.00 07/19/2024
REINSPECTION RESIDENTIAL ¤40.00 07/19/2024
CONNECTION FEES ¤1,166.26 05/01/2023
FIRE IMPACT FEE ADMIN ¤12.62 05/01/2023
FIRE IMPACT FEE ADMIN (¤12.62) 05/01/2023
IMPACT FEE FIRE ¤420.52 05/01/2023
IMPACT FEE PARKS ¤1,769.15 05/01/2023
IMPACT FEE SCHOOL ¤5,450.00 05/01/2023
IMPACT FEE TRANSPORTATION ¤1,764.00 05/01/2023
WATER -IRRIGATION INSPECTION ¤25.00 05/01/2023
PARKS IMPACT FEE ADMIN ¤53.07 05/01/2023
PARKS IMPACT FEE ADMIN (¤53.07) 05/01/2023
SURCHARGE FS 533.721 ¤4.00 05/01/2023
SURCHARGE - FS 468.631 ¤6.00 05/01/2023
SW ENG - FOUNDATION SURVEY ¤20.00 05/01/2023
SW ENG INSPECTION 80 ¤80.00 05/01/2023
SW ENG PRE APRON ¤30.00 05/01/2023
SW ENG - REVIEW 20 ¤20.00 05/01/2023
SW ENG RES REVIEW 200 ¤200.00 05/01/2023
TRANS IMPACT FEE ADMIN ¤52.92 05/01/2023
TRANS IMPACT FEE ADMIN (¤52.92) 05/01/2023
SEWER CREDIT (¤1,466.00) 05/01/2023
SEWER INSPECTION ¤25.00 05/01/2023
SEWER CAPITAL FACILITY ¤5,344.82 05/01/2023
WATER CAPITAL FACILITY FEE ¤3,923.88 05/01/2023
SITE PLAN 30 ¤30.00 05/01/2023
WATER- TURN ON ¤25.00 05/01/2023
ADJUSTMENT 50% (¤632.75) 05/01/2023
ADMINISTRATIVE RESIDENTIAL ¤30.00 05/01/2023
INSPECTION - RESIDENTIAL ¤962.50 05/01/2023
PLAN REVIEW - RESIDENTIAL ¤273.00 05/01/2023
Fees Total Due: ¤0.00 Total Paid: ¤19,615.38