I want to search for...
Permit #2022100577
Permit Details
Status: CANCEL
| Parcel Id: 07-11-31-7064-00370-0150 |
| CONDITIONED SPACE: 2003 sqft |
| GARAGE: 546 sqft |
| OPENED PORCH (WITH ROOF) : 246 sqft |
| OPENED PORCH (WITH ROOF) : 61 sqft |
| Total Square Footage: 2856 sqft |
| Block: 00370 |
| Subdivision: 2178 - SECTION 64-LAGUNA FOREST |
| Job Phone: 863-845-6967 |
| Location Address: 8 LLEBERRY PATH |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| NOC: NO DOCUMENTATION |
| Applicant name: LARRY SHERWIN THOMPSON |
| Owner: CARPENTER COMPANIES FLORIDA LLC |
|
Address SUITE #200 TAMPA, FL 33605 |
|
Address 1302 E 2ND AVENUE TAMPA, FL 33605 |
| Lot: 0150 |
| Contracted Stated Job Value: ¤190,000.00 |
| Job Description: SINGLE FAMILY RESIDENCE |
| Type: CN |
Contractor
THOMCO OF FLORIDA LLC
| Status | Location Address | State License Number | Phone |
| INACTIVE |
6381 ROBERTS RD KATHLEEN, FL 33849 |
CGC1513647 (Exp: 08/31/2024) | 863-845-6967 |
Sub Contractors
JOSEPH HORATIO STRADA JR
| Status | Location Address | State License Number | Phone |
| ACTIVE |
3400 ST JOHNS PARKWAY SANFORD, FL 32771 |
EC13003715 (Exp: 08/31/2026) | 877-906-1113 |
RUSSELL J CARTER
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
PO BOX 302 DELAND, FL 32721 |
CFC1425938 (Exp: 08/31/2026) | 386-736-4220 | 386-736-4219 |
JACK DOUGLAS LANIER
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
485 COMMERCE WAY LONGWOOD , FL 32750 |
CCC058022 (Exp: 08/31/2026) | (321)441-2300 | (321)441-2313 |
ROBERT MICHAEL RENNER
| Status | Location Address | State License Number | Phone |
| ACTIVE |
531 CODISCO WAY SANFORD, FL 32771 |
CAC051477 (Exp: 08/31/2026) | 407-333-2665 |
Inspection History
| Type | Request Date | Result | Inspector |
| FOUND SURVEY APPROVED (OFFICE) | |||
| PLUMBING 1ST ROUGH UNDERGROUND | |||
| GRAVITY SEWER TEST | |||
| ELECTRIC - EARLY POWER | |||
| MONOLITHIC SLAB | |||
| LATH/BRICK/ WATER BARRIER | |||
| TIE BEAM / LINTEL | |||
| ALL ROUGH | |||
| WALL SHEATHING | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | |||
| ROOF VALLEY & METAL | |||
| INSULATION | |||
| BLD - BUILDING FINAL | |||
| WATER METER INSTALLATION REQUEST | |||
| PEP TANK INSTALLATION REQUEST | |||
| U-CROSS CONNECTION | |||
| ROW- PRE-APRON (PRE-POUR) | |||
| ROW - FINAL APRON (AFTER POUR) | |||
| U - SEWER TIE IN | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | |||
| ROW FIELD SURVEY /GRADING CERTIFICATION | |||
| ROW - STORMWATER FINAL | |||
| U -UTILITY RESIDENTIAL FINAL |
Review History
| Department | Status | Date In | Date Out |
| ZON | COMPLETE | 01/11/2023 | 01/11/2023 |
| Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM | |||
| SW1 | HOLD | 01/11/2023 | 01/19/2023 |
| Note: Held By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM NEED TO HAVE EXISTING ELEVATIONS ON A 20' GRID IN THE LOT WITH PROPOSED ELEVATION WHERE ALL EXISTING ELEVATIONS ARE | |||
| BADMIN | INFORMATION | 01/10/2023 | 01/10/2023 |
| Note: Marked INFORMATION By: MICHELLE RAMOS - - MRAMOS@PALMCOASTGOV.COM Please remove address from file name. Example plan=plan | |||
| MECH | COMPLETE | 11/22/2022 | 11/22/2022 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 11/22/2022 | 11/23/2022 |
| Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM | |||
| ZON | HOLD | 11/22/2022 | 11/22/2022 |
| Note: Held By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM Repeat comment: Site plan still missing : Site plan still missing map panel # as indicated on the list on first hold. Land scape plan landscape is different than site plan please please make sure they match. The porch area is different on the right side of home. Elevation: Please make sure doors or windows facing the ROW have banding all around them. | |||
| SW1 | HOLD | 11/22/2022 | 12/02/2022 |
| Note: Held By: ROBERT GROSS - (386)986-4769 - RGROSS@PALMCOASTGOV.COM Must have an APPROVED site plan to be reviewed. | |||
| PLENV | COMPLETE | 10/12/2022 | 10/12/2022 |
| Note: Released By: JORDAN MYERS, C.F.M - (386)986-2320 - JMYERS@PALMCOASTGOV.COM No comments | |||
| BLD | HOLD | 10/11/2022 | 10/12/2022 |
| Note: Held By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM All comments below per the 2020 Florida Building Code PLAN REVIEW COMMENTS: Repeat Comments 1. Product Approval Specification Sheet; a. Properly identify ALL Florida Product Approval Number (i.e. 20461.#); there are various types of approved doors under the number provided. b. Provide approvals for wood connectors, wood anchors and truss plates. Per F.S. 471.025 and F.A.C. 61 G15-23.005. 2. Provide a completed and updated City of Palm Coast Roofing Worksheet. | |||
| CUSVC | COMPLETE | 10/11/2022 | 10/17/2022 |
| Note: Released By: CYNTHIA SCHWEERS - - CSCHWEERS@PALMCOASSTGOV.COM | |||
| ELEC | COMPLETE | 10/11/2022 | 10/12/2022 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 10/11/2022 | 10/11/2022 |
| Note: Released By: JOHN HOWARD - - JHOWARD@PALMCOASTGOV.COM | |||
| LOCATE | COMPLETE | 10/11/2022 | 10/19/2022 |
| Note: Released By: CANDACE STONE - - CSTONE@PALMCOASTGOV.COM | |||
| MECH | HOLD | 10/11/2022 | 10/12/2022 |
| Note: Held By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM Design location Energy Calcs and Heatload needs to be Daytona Beach | |||
| SW1 | HOLD | 10/11/2022 | 10/18/2022 |
| Note: Held By: ROBERT GROSS - (386)986-4769 - RGROSS@PALMCOASTGOV.COM See SW1 Checklist in the attachments dated 10/18/22. Please go through each item on the checklist and ensure that they are on the submitted proposed site plan for Stormwater Approval. | |||
| ZON | HOLD | 10/11/2022 | 10/13/2022 |
| Note: Held By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM Please make sure survey information below is also on the site plan. Site plan information that Zoning Dept. is looking for: Address of lot, Section, lot, and block. Width and length of property All easements on property Square footage of entire lot Width of walk way and driveway and materials Impervious ratio %- we would only ask for this if it’s close to meeting the maximum impervious for the zoning district of the lot Include the Ac pads and all other pads or patios with dimensions All legal description information with map book and page number All Flood zones if multiple on property please include on site plan, Map Panel Number All setbacks Front, Rear, and both sides – the setbacks should be provided from the CLOSEST point of the structure to the described property Land scape plan landscape is different than site plan please please make sure they match. The porch area is different on the right side of home. color sheet couldn't find that color or the LRV please make sure the name is correct Elevation: Please make sure doors or windows facing the ROW have banding all around them. | |||
| SWALE | COMPLETE | 10/11/2022 | 02/24/2023 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| SW1 | CANCEL |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| WATER- TURN ON | ¤25.00 | |
| ADJUSTMENT 50% | (¤468.61) | |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | |
| INSPECTION - RESIDENTIAL | ¤706.75 | |
| PLAN REVIEW - RESIDENTIAL | ¤200.46 | |
| CONNECTION FEES | ¤1,166.26 | |
| CONNECTION FEES | (¤750.00) | |
| FIRE IMPACT FEE ADMIN | ¤12.62 | |
| FIRE IMPACT FEE ADMIN | (¤12.62) | |
| IMPACT FEE FIRE | ¤420.52 | |
| IMPACT FEE PARKS | ¤1,769.15 | |
| IMPACT FEE SCHOOL | ¤5,450.00 | |
| IMPACT FEE TRANSPORTATION | ¤1,764.00 | |
| WATER -IRRIGATION INSPECTION | ¤25.00 | |
| PARKS IMPACT FEE ADMIN | ¤53.07 | |
| PARKS IMPACT FEE ADMIN | (¤53.07) | |
| SURCHARGE FS 533.721 | ¤3.06 | |
| SURCHARGE - FS 468.631 | ¤4.59 | |
| SW ENG - FOUNDATION SURVEY | ¤20.00 | |
| SW ENG INSPECTION 80 | ¤80.00 | |
| SW ENG PRE APRON | ¤30.00 | |
| SW ENG - REVIEW 20 | ¤20.00 | |
| SW ENG RES REVIEW 200 | ¤200.00 | |
| TRANS IMPACT FEE ADMIN | ¤52.92 | |
| TRANS IMPACT FEE ADMIN | (¤52.92) | |
| SEWER INSPECTION | ¤25.00 | |
| SEWER INSPECTION | (¤25.00) | |
| SEWER CAPITAL FACILITY | ¤5,344.82 | |
| SEWER CAPITAL FACILITY | (¤3,030.00) | |
| WATER CAPITAL FACILITY FEE | ¤3,923.88 | |
| WATER CAPITAL FACILITY FEE | (¤2,160.00) | |
| SITE PLAN 30 | ¤30.00 | |