I want to search for...
Permit #2022100743
Permit Details
Status: COED
| Parcel Id: 07-11-31-7031-00520-0140 |
| Total Square Footage: 1907 sqft |
| Block: 00520 |
| Subdivision: 2166 - SECTION 31-ROYAL PALMS |
| Job Phone: 904-236-5200 |
| Location Address: 28 RIVERINA DR |
| Type: RF - REROOF |
| Issue Date: 10/13/2022 |
| NOC: RECORDED |
| Applicant name: DALE KENT TADLOCK |
| Owner: ALBAN ASHLEY I |
|
Address 28 RIVERINA DR PALM COAST, FL 32164 |
| Lot: 0140 |
| Contracted Stated Job Value: ¤22,500.00 |
| Job Description: RE-ROOF |
| Type: CN |
Contractor
TADLOCK ROOFING INC
| Status | Location Address | State License Number | Phone |
| INACTIVE |
7999 PHILLIPS HWY UNIT 211 JACKSONVILLE, FL 32256 |
CCC1328417 (Exp: 08/31/2024) | 904-236-5200 |
Inspection History
| Type | Request Date | Result | Inspector |
| ROOF FINAL | 11/08/2022 | FINAL APPROVED | JWALKER |
| Note: 11/4/2022 - PREVIOUS INSPECTION NOTES 10/31/2022 - PREVIOUS INSPECTION NOTES Inspector Notes from Inspection 2468 1 st stop 8:40 am roof not ready The existing had two off ridge vents that have been covered up. Reinstall off ridge vents or submitt a revision to the building department showing the new ridge vent system meets the require ventilation for this roof. 10/31/22 Please submitt a revision to the building department for the change of the existing off ridge vents (closed off) to the new solar activated exhaust fan installed along with the ventilation calculations. The joiner seam at the electrical mast boot flashing needs to have sealant applied along the entire length of the seam. As per manufactures specs. 11/4/22 The existing off ridge vents have not been reinstalled. The contractor submitted a revision showing ridge vents. Ridge vents have not been installed. Contractor has installed a solar activated exhaust fan. Please submitt a revision to the building depart for the newly installed fan. Or reinstall the off ridge vents that were removed. | |||
| ROOF FINAL | 11/04/2022 | Disapproved -FEE REQUIRED | JWALKER |
| Note: 10/31/2022 - PREVIOUS INSPECTION NOTES Inspector Notes from Inspection 2468 1 st stop 8:40 am roof not ready The existing had two off ridge vents that have been covered up. Reinstall off ridge vents or submitt a revision to the building department showing the new ridge vent system meets the require ventilation for this roof. 10/31/22 Please submitt a revision to the building department for the change of the existing off ridge vents (closed off) to the new solar activated exhaust fan installed along with the ventilation calculations. The joiner seam at the electrical mast boot flashing needs to have sealant applied along the entire length of the seam. As per manufactures specs. 11/4/22 The existing off ridge vents have not been reinstalled. The contractor submitted a revision showing ridge vents. Ridge vents have not been installed. Contractor has installed a solar activated exhaust fan. Please submitt a revision to the building depart for the newly installed fan. Or reinstall the off ridge vents that were removed. | |||
| ROOF FINAL | 10/31/2022 | Disapproved - NO FEE | JWALKER |
| Note: Inspector Notes from Inspection 2468 1 st stop 8:40 am roof not ready The existing had two off ridge vents that have been covered up. Reinstall off ridge vents or submitt a revision to the building department showing the new ridge vent system meets the require ventilation for this roof. 10/31/22 Please submitt a revision to the building department for the change of the existing off ridge vents (closed off) to the new solar activated exhaust fan installed along with the ventilation calculations. The joiner seam at the electrical mast boot flashing needs to have sealant applied along the entire length of the seam. As per manufactures specs. | |||
| ROOF AFFIDAVIT | 10/27/2022 | APPROVED | MDEFREITAS |
| ROOF IN PROGRESS- MIDROOF | 10/24/2022 | APPROVED - AS NOTED | JWALKER |
| Note: 1 st stop 8:40 am roof not ready The existing had two off ridge vents that have been covered up. Reinstall off ridge vents or submitt a revision to the building department showing the new ridge vent system meets the require ventilation for this roof. |
Review History
| Department | Status | Date In | Date Out |
| BLD | COMPLETE | 11/07/2022 | 11/07/2022 |
| Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 11/03/2022 | 11/03/2022 |
| Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| PLAN REVIEW - REVISION | ¤32.50 | 11/09/2022 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 11/07/2022 |
| PLAN REVIEW - REVISION | ¤32.50 | 11/03/2022 |
| ADJUSTMENT 50% | (¤46.63) | 10/13/2022 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 10/13/2022 |
| INSPECTION - RESIDENTIAL | ¤63.25 | 10/13/2022 |
| SURCHARGE FS 533.721 | ¤2.00 | 10/13/2022 |
| SURCHARGE - FS 468.631 | ¤2.00 | 10/13/2022 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤155.62 |