I want to search for...
Permit #2022101014
Permit Details
Status: CANCEL
| Parcel Id: 07-11-31-7031-00410-0030 |
| CONDITIONED SPACE: 2529 sqft |
| GARAGE: 573 sqft |
| OPENED PORCH (WITH ROOF) : 558 sqft |
| Total Square Footage: 3660 sqft |
| Block: 00410 |
| Subdivision: 2166 - SECTION 31-ROYAL PALMS |
| Job Phone: 386-237-5837 |
| Location Address: 41 RICHMOND DR |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 12/08/2022 |
| NOC: RECORDED |
| Applicant name: MARSEL GILMANSHIN |
| Owner: 41 RICHMOND DRIVE TRUST |
|
Address 1 SURREY COURT PALM COAST, FL 32137 |
| Lot: 0030 |
| Contracted Stated Job Value: ¤250,000.00 |
| Job Description: SINGLE FAMILY RESIDENCE |
| Type: CN |
Contractor
GILMANS DEVELOPMENT CORP
| Status | Location Address | State License Number | Phone |
| ACTIVE |
4873 PALM COAST PARKWAY NW #4 PALM COAST, FL 32137 |
CBC1263180 (Exp: 08/31/2026) | 386-237-5837 |
Sub Contractors
MAXIM BUDNIK
| Status | Location Address | State License Number | Phone |
| ACTIVE |
9788 HALSEY RD JACKSONVILLE, FL 32246 |
EC13007415 (Exp: 08/31/2026) | 904-509-7306 |
MAXIM BUDNIK
| Status | Location Address | State License Number |
| ACTIVE |
3 WAVECREST PL PALM COAST, FL 32164 |
CAC1818445 (Exp: 08/31/2026) |
THOMAS WALTER ALBANO
| Status | Location Address | State License Number | Phone | Fax |
| INACTIVE |
P. O. BOX 352075 Palm Coast, FL 32135 |
CFC045991 (Exp: 08/31/2024) | 386-437-2795 | (386)437-2781 |
Inspection History
| Type | Request Date | Result | Inspector |
| LATH/BRICK/ WATER BARRIER | 04/02/2024 | APPROVED - AS NOTED | AGAETANO |
| Note: Inspector Notes from Inspection 2460 12/20/23 Truss Number 1 web member fix requires a scab on boths sides of the broken web. Check for correction and ALL ROUGH inspection. 11/30/2023 - PREVIOUS INSPECTION NOTES 11/30/23 1. The broken web member on truss 1 has not been done correctly refer to page MII- Rep in the Mitek engineering packet. 2. Double girder trusses 14 and 25 have not been fastened together as per the specs. 7"o.c. at the top chord and 9" o.c. at the webs and bottom chord. Refer to truss engineering packet for more info. 3. As was listed at the prior inspection. The over framing rafter at the front entry and the garage. Hold down straps have not been fastened to the trusses below. 11/27/2023 - PREVIOUS INSPECTION NOTES Item 1 listed below has not been corrected. Unable to do the inspection. 11/15/2023 - PREVIOUS INSPECTION NOTES 1. Please have a full set of approved drawings onsite for all inspections. 2. A walk through of the building revealed. Multiple trusses missing hold down anchors. Locations to garage wall above side door. CMU wall above the slider. Right side wall straps not nailed. 3. Over framing hold down achors not nailed. Please check building throughly before reinspection to avoid fees. Full inspection still needed. 04-02-2024 Truss Number 1 web member fix requires a scab on boths sides of the broken web. Check for correction and ALL ROUGH inspection. | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 12/20/2023 | APPROVED - AS NOTED | JWALKER |
| Note: 12/20/23 Truss Number 1 web member fix requires a scab on boths sides of the broken web. Check for correction and ALL ROUGH inspection. 11/30/2023 - PREVIOUS INSPECTION NOTES 11/30/23 1. The broken web member on truss 1 has not been done correctly refer to page MII- Rep in the Mitek engineering packet. 2. Double girder trusses 14 and 25 have not been fastened together as per the specs. 7"o.c. at the top chord and 9" o.c. at the webs and bottom chord. Refer to truss engineering packet for more info. 3. As was listed at the prior inspection. The over framing rafter at the front entry and the garage. Hold down straps have not been fastened to the trusses below. 11/27/2023 - PREVIOUS INSPECTION NOTES Item 1 listed below has not been corrected. Unable to do the inspection. 11/15/2023 - PREVIOUS INSPECTION NOTES 1. Please have a full set of approved drawings onsite for all inspections. 2. A walk through of the building revealed. Multiple trusses missing hold down anchors. Locations to garage wall above side door. CMU wall above the slider. Right side wall straps not nailed. 3. Over framing hold down achors not nailed. Please check building throughly before reinspection to avoid fees. Full inspection still needed. | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 11/30/2023 | Disapproved -FEE REQUIRED | JWALKER |
| Note: 11/30/23 1. The broken web member on truss 1 has not been done correctly refer to page MII- Rep in the Mitek engineering packet. 2. Double girder trusses 14 and 25 have not been fastened together as per the specs. 7"o.c. at the top chord and 9" o.c. at the webs and bottom chord. Refer to truss engineering packet for more info. 3. As was listed at the prior inspection. The over framing rafter at the front entry and the garage. Hold down straps have not been fastened to the trusses below. 4. Truss 25 missing a hold down anchor right side CMU wall. 11/27/2023 - PREVIOUS INSPECTION NOTES Item 1 listed below has not been corrected. Unable to do the inspection. 11/15/2023 - PREVIOUS INSPECTION NOTES 1. Please have a full set of approved drawings onsite for all inspections. 2. A walk through of the building revealed. Multiple trusses missing hold down anchors. Locations to garage wall above side door. CMU wall above the slider. Right side wall straps not nailed. 3. Over framing hold down achors not nailed. Please check building throughly before reinspection to avoid fees. Full inspection still needed. | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 11/27/2023 | Disapproved -FEE REQUIRED | JWALKER |
| Note: Item 1 listed below has not been corrected. Unable to do the inspection. 11/15/2023 - PREVIOUS INSPECTION NOTES 1. Please have a full set of approved drawings onsite for all inspections. 2. A walk through of the building revealed. Multiple trusses missing hold down anchors. Locations to garage wall above side door. CMU wall above the slider. Right side wall straps not nailed. 3. Over framing hold down achors not nailed. Please check building throughly before reinspection to avoid fees. Full inspection still needed. | |||
| ROOF VALLEY & METAL | 11/27/2023 | APPROVED | JWALKER |
| Note: 11/15/2023 - PREVIOUS INSPECTION NOTES Rear wall. Left side of the slider at the corner of the CMU wall. Above is an area that will required overframing. A rafter will need to be installed and anchored. Maximum spacing of roof truss members to support sheating is 24". WFCM | |||
| ROOF VALLEY & METAL | 11/15/2023 | Disapproved - NO FEE | JWALKER |
| Note: Rear wall. Left side of the slider at the corner of the CMU wall. Above is an area that will required overframing. A rafter will need to be installed and anchored. Maximum spacing of roof truss members to support sheating is 24". WFCM | |||
| WALL SHEATHING | 11/15/2023 | APPROVED | JWALKER |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 11/15/2023 | Disapproved -FEE REQUIRED | JWALKER |
| Note: 1. Please have a full set of approved drawings onsite for all inspections. 2. A walk through of the building revealed. Multiple trusses missing hold down anchors. Locations to garage wall above side door. CMU wall above the slider. Right side wall straps not nailed. 3. Over framing hold down achors not nailed. Please check building throughly before reinspection to avoid fees. Full inspection still needed. | |||
| FOUND SURVEY APPROVED (OFFICE) | 11/14/2023 | APPROVED | TBAKER |
| TIE BEAM / LINTEL | 05/19/2023 | APPROVED | KSANDOE |
| MONOLITHIC SLAB | 04/05/2023 | APPROVED | JWALKER |
| Note: 3/24/2023 - PREVIOUS INSPECTION NOTES 1. Remove the root from the right side back footing. Marked the print of the location. 2. The F-5 footings are to be 16" deep. 3. Install UFER groung back side of garage. 4. Rear columns X3 missing vertiacal rebar. 5. The slab is to be a minimum of 4" deep. Remove excess soil and tamp. Test string lines have been left in place. Please reinstall test lines after slab is corrected. | |||
| MONOLITHIC SLAB | 03/24/2023 | Disapproved - NO FEE | JWALKER |
| Note: 1. Remove the root from the right side back footing. Marked the print of the location. 2. The F-5 footings are to be 16" deep. 3. Install UFER groung back side of garage. 4. Rear columns X3 missing vertiacal rebar. 5. The slab is to be a minimum of 4" deep. Remove excess soil and tamp. Test string lines have been left in place. Please reinstall test lines after slab is corrected. | |||
| PLUMBING 1ST ROUGH UNDERGROUND | 03/06/2023 | APPROVED - AS NOTED | MGIBSON |
| Note: NEED PORTABLE RESTROOM BY SLABINSPECTION | |||
| GRAVITY SEWER TEST | 03/06/2023 | Disapproved - NO FEE | MGIBSON |
| Note: SEWER NOT RAN YET | |||
| WATER METER INSTALLATION REQUEST | 01/09/2023 | APPROVED | CSTONE |
| PEP TANK INSTALLATION REQUEST | |||
| U-CROSS CONNECTION | |||
| ROW- PRE-APRON (PRE-POUR) | |||
| ROW - FINAL APRON (AFTER POUR) | |||
| U - SEWER TIE IN | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | |||
| ROW FIELD SURVEY /GRADING CERTIFICATION | |||
| ROW - STORMWATER FINAL | |||
| U -UTILITY RESIDENTIAL FINAL | |||
| GRAVITY SEWER TEST | |||
| Note: 3/6/2023 - PREVIOUS INSPECTION NOTES SEWER NOT RAN YET | |||
| ELECTRIC - EARLY POWER | |||
| ALL ROUGH | |||
| INSULATION | |||
| BLD - BUILDING FINAL |
Review History
| Department | Status | Date In | Date Out |
| ENGIN1 | COMPLETE | 11/13/2023 | 11/14/2023 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 11/13/2023 | 11/13/2023 |
| Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM | |||
| ZON | HOLD | 12/07/2022 | 12/07/2022 |
| Note: Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM Please bring in the original right of way agreement for recording | |||
| ZON | COMPLETE | 12/07/2022 | 12/07/2022 |
| Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM | |||
| ZON | HOLD | 12/05/2022 | 12/06/2022 |
| Note: Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM Must have a minimum of 8 shrubs in front and four shrubs along each front side wrapping corners. Crotons are not credited foundation plantings. These do not count toward the required 16 foundation plantings. The trust is under a Dmitry but on the right of way agreement it is signed by Dima. These must match the way the trust is signed and it must be notarized that way. Please include the signature page of the trust for us to verify. | |||
| BLD | COMPLETE | 12/05/2022 | 12/06/2022 |
| Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM | |||
| ELEC | COMPLETE | 11/28/2022 | 11/29/2022 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ZON | HOLD | 11/28/2022 | 11/28/2022 |
| Note: Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM Must have a minimum of 8 shrubs in front and four shrubs along each side wrapping corners. These must be at least 3 gallon. The one gallon shrubs and crotons are not credited foundation plantings. These must be planted. The way you are showing it looks like some will be on concrete. There must be a space for the foundation plantings. Please show this on site and landscape plans. This is in a trust please provide us the first couple pages of the trust so we can verify the wording and the authorized signer are correct on the right of way agreement. | |||
| MECH | COMPLETE | 11/28/2022 | 11/29/2022 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| BLD | HOLD | 11/28/2022 | 12/02/2022 |
| Note: Held By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM All comments below per the 2020 Florida Building Code 1. Product Approval Specification Sheet; a. Properly identify ALL Florida Product Approval Number (i.e. 742.#); there are various types of approved doors under these numbers provided. Per F.S. 471.025 and F.A.C. 61 G15-23.005. 2. OK | |||
| BLD | HOLD | 10/19/2022 | 10/24/2022 |
| Note: Held By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM All comments below per the 2020 Florida Building Code 1. Product Approval Specification Sheet; a. Properly identify ALL Florida Product Approval Number (i.e. 742.#); there are various types of approved doors under these numbers provided. Per F.S. 471.025 and F.A.C. 61 G15-23.005. 2. Provide a updated City of Palm Coast Roofing Worksheet. | |||
| CUSVC | COMPLETE | 10/19/2022 | 10/20/2022 |
| Note: Released By: HALEIGH HAND - - | |||
| ELEC | HOLD | 10/19/2022 | 10/19/2022 |
| Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM Need correct outlet spacing in bed 3 and 4. NEC 2017 210.52 | |||
| ENGIN1 | COMPLETE | 10/19/2022 | 10/19/2022 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| LOCATE | COMPLETE | 10/19/2022 | 10/24/2022 |
| Note: Released By: CANDACE STONE - - CSTONE@PALMCOASTGOV.COM | |||
| MECH | HOLD | 10/19/2022 | 10/20/2022 |
| Note: Held By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM Energy Calcs need to be signed by the builder per 107.1 FBC Residential 2020 7th edition | |||
| SW1 | COMPLETE | 10/19/2022 | 10/26/2022 |
| Note: Released By: ROBERT GROSS - (386)986-4769 - RGROSS@PALMCOASTGOV.COM | |||
| ZON | HOLD | 10/19/2022 | 10/20/2022 |
| Note: Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM Must have four shrubs along each side wrapping corners. These must be at least 3 gallon the one gallon shrubs do not count. Please provide an electronic copy of a right of way agreement signed by owners and notarized for paver driveway. Once approved we will ask that the original be turned in for recording. Site plan and landscape plan layout of front entry and driveway/walkway do not match. | |||
| SWALE | COMPLETE | 10/19/2022 | 02/28/2023 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| WATER- TURN ON | ¤25.00 | 12/08/2022 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 12/08/2022 |
| ADJUSTMENT 50% | (¤592.16) | 12/08/2022 |
| INSPECTION - RESIDENTIAL | ¤899.25 | 12/08/2022 |
| PLAN REVIEW - RESIDENTIAL | ¤255.06 | 12/08/2022 |
| CONNECTION FEES | ¤1,077.88 | 12/08/2022 |
| FIRE IMPACT FEE ADMIN | ¤12.62 | 12/08/2022 |
| FIRE IMPACT FEE ADMIN | (¤12.62) | 12/08/2022 |
| IMPACT FEE PARKS | ¤1,769.15 | 12/08/2022 |
| IMPACT FEE FIRE | ¤420.52 | 12/08/2022 |
| IMPACT FEE SCHOOL | ¤5,450.00 | 12/08/2022 |
| RECORDING FEE REIMBURSE DOC | ¤44.00 | 12/08/2022 |
| WATER -IRRIGATION INSPECTION | ¤25.00 | 12/08/2022 |
| IMPACT FEE TRANSPORTATION | ¤1,764.00 | 12/08/2022 |
| PARKS IMPACT FEE ADMIN | ¤53.07 | 12/08/2022 |
| SURCHARGE FS 533.721 | ¤3.77 | 12/08/2022 |
| PARKS IMPACT FEE ADMIN | (¤53.07) | 12/08/2022 |
| SURCHARGE - FS 468.631 | ¤5.65 | 12/08/2022 |
| SW ENG - FOUNDATION SURVEY | ¤20.00 | 12/08/2022 |
| SW ENG PRE APRON | ¤30.00 | 12/08/2022 |
| SW ENG INSPECTION 80 | ¤80.00 | 12/08/2022 |
| SW ENG - REVIEW 20 | ¤20.00 | 12/08/2022 |
| SW ENG RES REVIEW 200 | ¤200.00 | 12/08/2022 |
| TRANS IMPACT FEE ADMIN | ¤52.92 | 12/08/2022 |
| TRANS IMPACT FEE ADMIN | (¤52.92) | 12/08/2022 |
| SEWER CREDIT | (¤2,465.75) | 12/08/2022 |
| SEWER CAPITAL FACILITY | ¤4,939.76 | 12/08/2022 |
| SEWER INSPECTION | ¤25.00 | 12/08/2022 |
| WATER CAPITAL FACILITY FEE | ¤3,626.50 | 12/08/2022 |
| SITE PLAN 30 | ¤30.00 | 12/08/2022 |
| SITE PLAN 30 | ¤30.00 | 12/07/2022 |
| WATER- TURN ON | (¤25.00) | 12/07/2022 |
| SITE PLAN 30 | (¤30.00) | 12/07/2022 |
| SEWER CAPITAL FACILITY | (¤4,939.76) | 12/07/2022 |
| SEWER CAPITAL FACILITY | ¤4,939.76 | 12/07/2022 |
| WATER CAPITAL FACILITY FEE | ¤3,626.50 | 12/07/2022 |
| WATER CAPITAL FACILITY FEE | (¤3,626.50) | 12/07/2022 |
| SEWER CREDIT | (¤2,465.75) | 12/07/2022 |
| SEWER INSPECTION | ¤25.00 | 12/07/2022 |
| SEWER INSPECTION | (¤25.00) | 12/07/2022 |
| SEWER CREDIT | ¤2,465.75 | 12/07/2022 |
| TRANS IMPACT FEE ADMIN | ¤52.92 | 12/07/2022 |
| SW ENG RES REVIEW 200 | ¤200.00 | 12/07/2022 |
| TRANS IMPACT FEE ADMIN | ¤52.92 | 12/07/2022 |
| TRANS IMPACT FEE ADMIN | (¤52.92) | 12/07/2022 |
| TRANS IMPACT FEE ADMIN | (¤52.92) | 12/07/2022 |
| SW ENG RES REVIEW 200 | (¤200.00) | 12/07/2022 |
| SW ENG PRE APRON | (¤30.00) | 12/07/2022 |
| SW ENG PRE APRON | ¤30.00 | 12/07/2022 |
| SW ENG - REVIEW 20 | ¤20.00 | 12/07/2022 |
| SW ENG - REVIEW 20 | (¤20.00) | 12/07/2022 |
| SW ENG - FOUNDATION SURVEY | ¤20.00 | 12/07/2022 |
| SW ENG INSPECTION 80 | ¤80.00 | 12/07/2022 |
| SW ENG INSPECTION 80 | (¤80.00) | 12/07/2022 |
| SW ENG - FOUNDATION SURVEY | (¤20.00) | 12/07/2022 |
| SURCHARGE FS 533.721 | (¤3.77) | 12/07/2022 |
| SURCHARGE FS 533.721 | ¤3.77 | 12/07/2022 |
| SURCHARGE - FS 468.631 | ¤5.65 | 12/07/2022 |
| SURCHARGE - FS 468.631 | (¤5.65) | 12/07/2022 |
| PARKS IMPACT FEE ADMIN | ¤53.07 | 12/07/2022 |
| WATER -IRRIGATION INSPECTION | (¤25.00) | 12/07/2022 |
| WATER -IRRIGATION INSPECTION | ¤25.00 | 12/07/2022 |
| PARKS IMPACT FEE ADMIN | ¤53.07 | 12/07/2022 |
| PARKS IMPACT FEE ADMIN | (¤53.07) | 12/07/2022 |
| PARKS IMPACT FEE ADMIN | (¤53.07) | 12/07/2022 |
| RECORDING FEE REIMBURSE DOC | ¤44.00 | 12/07/2022 |
| IMPACT FEE TRANSPORTATION | ¤1,764.00 | 12/07/2022 |
| IMPACT FEE TRANSPORTATION | (¤1,764.00) | 12/07/2022 |
| RECORDING FEE REIMBURSE DOC | (¤44.00) | 12/07/2022 |
| IMPACT FEE PARKS | (¤1,769.15) | 12/07/2022 |
| IMPACT FEE PARKS | ¤1,769.15 | 12/07/2022 |
| IMPACT FEE SCHOOL | ¤5,450.00 | 12/07/2022 |
| IMPACT FEE SCHOOL | (¤5,450.00) | 12/07/2022 |
| FIRE IMPACT FEE ADMIN | ¤12.62 | 12/07/2022 |
| FIRE IMPACT FEE ADMIN | (¤12.62) | 12/07/2022 |
| IMPACT FEE FIRE | ¤420.52 | 12/07/2022 |
| IMPACT FEE FIRE | (¤420.52) | 12/07/2022 |
| FIRE IMPACT FEE ADMIN | ¤12.62 | 12/07/2022 |
| FIRE IMPACT FEE ADMIN | (¤12.62) | 12/07/2022 |
| PLAN REVIEW - RESIDENTIAL | ¤255.06 | 12/07/2022 |
| CONNECTION FEES | ¤1,077.88 | 12/07/2022 |
| CONNECTION FEES | (¤1,077.88) | 12/07/2022 |
| PLAN REVIEW - RESIDENTIAL | (¤255.06) | 12/07/2022 |
| ADMINISTRATIVE RESIDENTIAL | (¤30.00) | 12/07/2022 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 12/07/2022 |
| INSPECTION - RESIDENTIAL | ¤899.25 | 12/07/2022 |
| INSPECTION - RESIDENTIAL | (¤899.25) | 12/07/2022 |
| WATER- TURN ON | ¤25.00 | 12/07/2022 |
| ADJUSTMENT 50% | (¤592.16) | 12/07/2022 |
| ADJUSTMENT 50% | ¤592.16 | 12/07/2022 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤17,682.63 |