I want to search for...

Permit #2022101217

Permit Details

Status: COED

Parcel Id: 07-11-31-7033-00190-0060
CONDITIONED SPACE: 2870 sqft
GARAGE: 1008 sqft
OPENED PORCH (WITH ROOF) : 120 sqft
Total Square Footage: 3998 sqft
Block: 00190
Subdivision: 2184 - SECTION 33-ROYAL PALMS
Job Phone: 863-647-5815
Location Address: 42 REGENCY DR
Type: DU - DUPLEX
Issue Date: 03/22/2023
NOC: RECORDED
Applicant name: MARK ALLAN HULBERT
Owner: YINGLING, CASEY & COX, JULIANA

Address

42 REGENCY DR

PALM COAST, FL 32164

Lot: 0060
Contracted Stated Job Value: ¤400,000.00
Job Description: Duplex
Type: CN

Contractor

HULBERT HOMES INC
Status Location Address State License Number Phone
INACTIVE

PO BOX 6254

LAKELAND, FL 33813

CRC1331304 (Exp: 08/31/2026) 863-647-5815

Sub Contractors

ANTONIO VINCENZO DAHM
Status Location Address State License Number Phone
ACTIVE

10 RYBAR LANE

PALM COAST, FL 32164

CFC1429951 (Exp: 08/31/2026) 386-237-5692
BRETT CHRISTIAN GIBSON
Status Location Address State License Number Phone
ACTIVE

250 SEGOVIA RD

ST AUGUSTINE, FL 32086

CAC1818423 (Exp: 08/31/2026) 904-229-8131
STEPHEN COURTEAUX
Status Location Address State License Number Phone Fax
ACTIVE

85 North Yonge Street

Ormond Beach, FL 32174

EC13001748 (Exp: 08/31/2026) (386) 672-4900 386-676-7472
DUSTIN L ESTEP
Status Location Address State License Number Phone Fax
ACTIVE

2041 N HIAWASSEE RD

APOPKA, FL 32703

CCC1330971 (Exp: 08/31/2026) 407-702-0206 352-988-6629

Inspection History

Type Request Date Result Inspector
ROW - FINAL APRON (AFTER POUR) 10/13/2023 APPROVED FSLADISH
Note: 10/12/23 PIPES OK. CUTS MADE. CULVERTS CLEAR. HOT PATCHES COMPLETED. LOOKED GOOD AT THE TIME OF THIS INSPECTION. At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved. ________________________________________________________________________________________________________________________ Inspector Notes from Inspection 9465 09/06/23 THE CULVERT PIPES ARE BOTH ALMOST TOTALLY FULL OF DIRT AND SILT CAUSING HARDLY ANY WATER TO DRAIN. ON THE RIGHT SIDE YO WILL NEED TO SOD AND MATCH GRADE IN THE BARE AREA. I AM GOING TO APPROVE FIELD SURVEY AS NOTED. INPECTORS NOTE...... ***DO NOT PASS AFTERPOUR OR ROW FINAL TILL CULVERT PIPES ARE COMPLETELY CLEANED OUT*** _________________________________________________________________________________________________________________________ 9/5/2023 - PREVIOUS INSPECTION NOTES YOUR SOD IN YOUR ROAD SIDE SWALE DOES NOT MATCH THE GRADE AT HOUSE #40 SO ITS NOT ALLOWING THE WATER TO FLOW ------------------------------------------------------------------------------------------- 8/29/2023 - PREVIOUS INSPECTION NOTES THE ROAD SIDE SWALE IS HOLDING THE WATER FROM FLOWING TO OUT FALL --------------------------------------------------------------------------------------------- 8/9/2023 - PREVIOUS INSPECTION NOTES 08/09/23 You must first pass the final survey before a field survey can be done.
ROW - FINAL INSPECTION 10/13/2023 CANCELLED BY APPLICANT PFLANAGAN
Note: Inspector Notes from Inspection 9465 09/06/23 THE CULVERT PIPES ARE BOTH ALMOST TOTALLY FULL OF DIRT AND SILT CAUSING HARDLY ANY WATER TO DRAIN. ON THE RIGHT SIDE YO WILL NEED TO SOD AND MATCH GRADE IN THE BARE AREA. I AM GOING TO APPROVE FIELD SURVEY AS NOTED. INPECTORS NOTE...... ***DO NOT PASS AFTERPOUR OR ROW FINAL TILL CULVERT PIPES ARE COMPLETELY CLEANED OUT*** _________________________________________________________________________________________________________________________ 9/5/2023 - PREVIOUS INSPECTION NOTES YOUR SOD IN YOUR ROAD SIDE SWALE DOES NOT MATCH THE GRADE AT HOUSE #40 SO ITS NOT ALLOWING THE WATER TO FLOW ------------------------------------------------------------------------------------------- 8/29/2023 - PREVIOUS INSPECTION NOTES THE ROAD SIDE SWALE IS HOLDING THE WATER FROM FLOWING TO OUT FALL --------------------------------------------------------------------------------------------- 8/9/2023 - PREVIOUS INSPECTION NOTES 08/09/23 You must first pass the final survey before a field survey can be done.
U -UTILITY RESIDENTIAL FINAL 10/13/2023 FINAL APPROVED LFITZGERALD
Note: Inspector Notes from Inspection 9035 well irrigation(out of unit B)-no cross connection
ROW - FINAL INSPECTION 10/12/2023 APPROVED - AS NOTED FSLADISH
Note: 10/12/23 MAKE SURE ALL TRASH AND DEBRIS ARE PICKED UP. CULVERT PIPES HAVE BEEN CLEANED OUT AS REQUIRED PER PREVIOUS INSPECTION. APPROVING AS NOTED. At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved. _______________________________________________________________________________________________________________________ 10/12/2023 - PREVIOUS INSPECTION NOTES Inspector Notes from Inspection 9465 09/06/23 THE CULVERT PIPES ARE BOTH ALMOST TOTALLY FULL OF DIRT AND SILT CAUSING HARDLY ANY WATER TO DRAIN. ON THE RIGHT SIDE YO WILL NEED TO SOD AND MATCH GRADE IN THE BARE AREA. I AM GOING TO APPROVE FIELD SURVEY AS NOTED. INPECTORS NOTE...... ***DO NOT PASS AFTERPOUR OR ROW FINAL TILL CULVERT PIPES ARE COMPLETELY CLEANED OUT*** _________________________________________________________________________________________________________________________ 9/5/2023 - PREVIOUS INSPECTION NOTES YOUR SOD IN YOUR ROAD SIDE SWALE DOES NOT MATCH THE GRADE AT HOUSE #40 SO ITS NOT ALLOWING THE WATER TO FLOW ------------------------------------------------------------------------------------------- 8/29/2023 - PREVIOUS INSPECTION NOTES THE ROAD SIDE SWALE IS HOLDING THE WATER FROM FLOWING TO OUT FALL --------------------------------------------------------------------------------------------- 8/9/2023 - PREVIOUS INSPECTION NOTES 08/09/23 You must first pass the final survey before a field survey can be done.
BLD - BUILDING FINAL 10/12/2023 FINAL APPROVED JWALKER
Note: 10/6/2023 - PREVIOUS INSPECTION NOTES 10/6/23 Other inspections need to be completed prior to final being scheduled 10/4/2023 - PREVIOUS INSPECTION NOTES 1. The fire wall drywall nailing inspection will need to be passed before building final. 2. The garage attic space has been sprayed foamed the space is being used for storage. Spray foam is to have a thermal barrier when space is used for storage. R-316 3. Energy calculations do not match the units installed. 4. Outlet within 6' of the kitchen sink need to be GFI protected 5. The AHU heat appliance labels have not been marked off identifying the appliance installed. 6. Unit A shower tile floor is not completed. 7. The attic access lids need to be 5/8" sheet rock of 3/4 inch plywood minimum due to the ceiling being part of the fire barrier.
FIREWALL DRYWALL NAILING 10/12/2023 APPROVED JWALKER
Note: 10/6/2023 - PREVIOUS INSPECTION NOTES 10/6/23 Revision is not approved 10/4/2023 - PREVIOUS INSPECTION NOTES 10/4/23 1.The letter submitted for the fire wall change mentions the ceilings it does not refer to the separating wall. The Print shows a 2 hour fire wall. with 5/8" sheet rock from floor to roof deck on both sides of the wall. 1/2" sheetrock has been used on the separating wall in the living space. Contractor will need to installed 5/8" as detailed or have the engineer submit a revision to the building department showing how to correct the living space area of the separating wall. Ceilings 5/8 fire resistant sheet rock passed inspection. and the 1/2" used as a draft stop in the attic area passes. 10/3/2023 - PREVIOUS INSPECTION NOTES 1. Print show a 2 hour fire wall. with 5/8" sheet rock from floor to roof deck on both sides of the wall. The contractor has sprayed foamed the attic part of the fire wall, and has finished painted the living space parts of the fire wall. Contractor will need to reschedule the inspection and contact the listed inspector the morning of the inspection from 7:30 am to 8:30am and set a time to meet for a deconstruction inspection to verify the fire walls have been done as per the plans.
FIREWALL FINAL 10/12/2023 FINAL APPROVED JWALKER
Note: 10/6/2023 - PREVIOUS INSPECTION NOTES 10/6/23 Revision is not approved, can not schedule until the revision is approved 10/4/2023 - PREVIOUS INSPECTION NOTES 10/4/23 Fire wall final cannot be completed until the firewall drywall nailing has been approved. 10/3/2023 - PREVIOUS INSPECTION NOTES Fire wall final cannot be completed until the firewall drywall nailing has been approved.
FIREWALL FINAL 10/06/2023 Disapproved - NO FEE RMARTIN
Note: 10/6/23 Revision is not approved, can not schedule until the revision is approved 10/4/2023 - PREVIOUS INSPECTION NOTES 10/4/23 Fire wall final cannot be completed until the firewall drywall nailing has been approved. 10/3/2023 - PREVIOUS INSPECTION NOTES Fire wall final cannot be completed until the firewall drywall nailing has been approved.
FIREWALL DRYWALL NAILING 10/06/2023 Disapproved - NO FEE RMARTIN
Note: 10/6/23 Revision is not approved 10/4/2023 - PREVIOUS INSPECTION NOTES 10/4/23 1.The letter submitted for the fire wall change mentions the ceilings it does not refer to the separating wall. The Print shows a 2 hour fire wall. with 5/8" sheet rock from floor to roof deck on both sides of the wall. 1/2" sheetrock has been used on the separating wall in the living space. Contractor will need to installed 5/8" as detailed or have the engineer submit a revision to the building department showing how to correct the living space area of the separating wall. Ceilings 5/8 fire resistant sheet rock passed inspection. and the 1/2" used as a draft stop in the attic area passes. 10/3/2023 - PREVIOUS INSPECTION NOTES 1. Print show a 2 hour fire wall. with 5/8" sheet rock from floor to roof deck on both sides of the wall. The contractor has sprayed foamed the attic part of the fire wall, and has finished painted the living space parts of the fire wall. Contractor will need to reschedule the inspection and contact the listed inspector the morning of the inspection from 7:30 am to 8:30am and set a time to meet for a deconstruction inspection to verify the fire walls have been done as per the plans.
BLD - BUILDING FINAL 10/06/2023 Disapproved - NO FEE RMARTIN
Note: 10/6/23 Other inspections need to be completed prior to final being scheduled 10/4/2023 - PREVIOUS INSPECTION NOTES 1. The fire wall drywall nailing inspection will need to be passed before building final. 2. The garage attic space has been sprayed foamed the space is being used for storage. Spray foam is to have a thermal barrier when space is used for storage. R-316 3. Energy calculations do not match the units installed. 4. Outlet within 6' of the kitchen sink need to be GFI protected 5. The AHU heat appliance labels have not been marked off identifying the appliance installed. 6. Unit A shower tile floor is not completed. 7. The attic access lids need to be 5/8" sheet rock of 3/4 inch plywood minimum due to the ceiling being part of the fire barrier.
BLD - BUILDING FINAL 10/04/2023 Disapproved - NO FEE JWALKER
Note: 1. The fire wall drywall nailing inspection will need to be passed before building final. 2. The garage attic space has been sprayed foamed the space is being used for storage. Spray foam is to have a thermal barrier when space is used for storage. R-316 3. Energy calculations do not match the units installed. 4. Outlet within 6' of the kitchen sink need to be GFI protected 5. The AHU heat appliance labels have not been marked off identifying the appliance installed. 6. Unit A shower tile floor is not completed. 7. The attic access lids need to be 5/8" sheet rock of 3/4 inch plywood minimum due to the ceiling being part of the fire barrier.
U-CROSS CONNECTION 10/04/2023 APPROVED - AS NOTED LFITZGERALD
Note: well irrigation(out of unit B)-no cross connection
FIREWALL FINAL 10/04/2023 Disapproved - NO FEE JWALKER
Note: 10/4/23 Fire wall final cannot be completed until the firewall drywall nailing has been approved. 10/3/2023 - PREVIOUS INSPECTION NOTES Fire wall final cannot be completed until the firewall drywall nailing has been approved.
WINDOW NAILING 10/04/2023 APPROVED JWALKER
Note: 10/3/2023 - PREVIOUS INSPECTION NOTES 10/3/23 As listed below at the previous window nailing inspection. The product approval labels have not been supplied. If the windows and doors were changed from the products listed and approved on the product approval sheet please have the engineer submit a revision to the building department for the changes. Contractor will need to affix the labels to the doors and windows listed for reinspection. 6/6/2023 - PREVIOUS INSPECTION NOTES 6/6/23 Rear window and bathroom window for Unit B not installed. Product approval stickers not on the front doors, rear doors, or windows. Please provide product approval labels. Inspection for rear sliders, rear doors and front doors.
FIREWALL DRYWALL NAILING 10/04/2023 Disapproved - NO FEE JWALKER
Note: 10/4/23 1.The letter submitted for the fire wall change mentions the ceilings it does not refer to the separating wall. The Print shows a 2 hour fire wall. with 5/8" sheet rock from floor to roof deck on both sides of the wall. 1/2" sheetrock has been used on the separating wall in the living space. Contractor will need to installed 5/8" as detailed or have the engineer submit a revision to the building department showing how to correct the living space area of the separating wall. Ceilings 5/8 fire resistant sheet rock passed inspection. and the 1/2" used as a draft stop in the attic area passes. 10/3/2023 - PREVIOUS INSPECTION NOTES 1. Print show a 2 hour fire wall. with 5/8" sheet rock from floor to roof deck on both sides of the wall. The contractor has sprayed foamed the attic part of the fire wall, and has finished painted the living space parts of the fire wall. Contractor will need to reschedule the inspection and contact the listed inspector the morning of the inspection from 7:30 am to 8:30am and set a time to meet for a deconstruction inspection to verify the fire walls have been done as per the plans.
WINDOW NAILING 10/03/2023 Disapproved - NO FEE JWALKER
Note: 10/3/23 As listed below at the previous window nailing inspection. The product approval labels have not been supplied. If the windows and doors were changed from the products listed and approved on the product approval sheet please have the engineer submit a revision to the building department for the changes. Contractor will need to affix the labels to the doors and windows listed for reinspection. 6/6/2023 - PREVIOUS INSPECTION NOTES 6/6/23 Rear window and bathroom window for Unit B not installed. Product approval stickers not on the front doors, rear doors, or windows. Please provide product approval labels. Inspection for rear sliders, rear doors and front doors.
FIREWALL DRYWALL NAILING 10/03/2023 Disapproved - NO FEE JWALKER
Note: 1. Print show a 2 hour fire wall. with 5/8" sheet rock from floor to roof deck on both sides of the wall. The contractor has sprayed foamed the attic part of the fire wall, and has finished painted the living space parts of the fire wall. Contractor will need to reschedule the inspection and contact the listed inspector the morning of the inspection from 7:30 am to 8:30am and set a time to meet for a deconstruction inspection to verify the fire walls have been done as per the plans.
FIREWALL FINAL 10/03/2023 Disapproved - NO FEE JWALKER
Note: Fire wall final cannot be completed until the firewall drywall nailing has been approved.
BLD - BUILDING FINAL 10/02/2023 CANCELLED BY APPLICANT WEB
Note: 7/12/23 CHECK FOR CORRECT REVISION OF THE ELECTRICAL RISER AT FINAL BUILDING INSPECTION. ENSURE THE REVISION IS APPROVED AND MATCHES THE AS BULIT ELECTRCIAL RISER INSTALLED.
BLD - BUILDING FINAL 10/02/2023 Disapproved - NO FEE JWALKER
Note: There appears to be 3 open inspections, Fire wall nailing, fire wall final and window nailing. Builind final cannot be completed until these inspection have been done. Please contact the Rober Martin the cheif building inspection for further instructions. New inspection due to canceled inspection 7/12/23 CHECK FOR CORRECT REVISION OF THE ELECTRICAL RISER AT FINAL BUILDING INSPECTION. ENSURE THE REVISION IS APPROVED AND MATCHES THE AS BULIT ELECTRCIAL RISER INSTALLED.
ROW FIELD SURVEY /GRADING CERTIFICATION 09/06/2023 APPROVED - AS NOTED FSLADISH
Note: 09/06/23 THE CULVERT PIPES ARE BOTH ALMOST TOTALLY FULL OF DIRT AND SILT CAUSING HARDLY ANY WATER TO DRAIN. ON THE RIGHT SIDE YO WILL NEED TO SOD AND MATCH GRADE IN THE BARE AREA. I AM GOING TO APPROVE FIELD SURVEY AS NOTED. INPECTORS NOTE...... ***DO NOT PASS AFTERPOUR OR ROW FINAL TILL CULVERT PIPES ARE COMPLETELY CLEANED OUT*** _________________________________________________________________________________________________________________________ 9/5/2023 - PREVIOUS INSPECTION NOTES YOUR SOD IN YOUR ROAD SIDE SWALE DOES NOT MATCH THE GRADE AT HOUSE #40 SO ITS NOT ALLOWING THE WATER TO FLOW ------------------------------------------------------------------------------------------- 8/29/2023 - PREVIOUS INSPECTION NOTES THE ROAD SIDE SWALE IS HOLDING THE WATER FROM FLOWING TO OUT FALL --------------------------------------------------------------------------------------------- 8/9/2023 - PREVIOUS INSPECTION NOTES 08/09/23 You must first pass the final survey before a field survey can be done.
ROW FIELD SURVEY /GRADING CERTIFICATION 09/05/2023 Disapproved -FEE REQUIRED PFLANAGAN
Note: YOUR SOD IN YOUR ROAD SIDE SWALE DOES NOT MATCH THE GRADE AT HOUSE #40 SO ITS NOT ALLOWING THE WATER TO FLOW ------------------------------------------------------------------------------------------- 8/29/2023 - PREVIOUS INSPECTION NOTES THE ROAD SIDE SWALE IS HOLDING THE WATER FROM FLOWING TO OUT FALL --------------------------------------------------------------------------------------------- 8/9/2023 - PREVIOUS INSPECTION NOTES 08/09/23 You must first pass the final survey before a field survey can be done.
ROW FIELD SURVEY /GRADING CERTIFICATION 08/29/2023 Disapproved - NO FEE PFLANAGAN
Note: THE ROAD SIDE SWALE IS HOLDING THE WATER FROM FLOWING TO OUT FALL --------------------------------------------------------------------------------------------- 8/9/2023 - PREVIOUS INSPECTION NOTES 08/09/23 You must first pass the final survey before a field survey can be done.
ROW- FINAL SURVEY/GRADING CERTIFICATION 08/29/2023 Disapproved -FEE REQUIRED PFLANAGAN
Note: 1) Sec.300.01 (4,5,6) The tolerance along side lot lines is no more than 20 feet, with positive fall on each side. Positive fall is considered to be 0.10 feet in 20 feet ---------------------------------------------------------------------------------- 8/11/2023 - PREVIOUS INSPECTION NOTES 1) Sec.300.01 (4,5,6) The tolerance along side lot lines is no more than 20 feet, with positive fall on each side. Positive fall is considered to be 0.10 feet in 20 feet 2) NEED TO HAVE THE FFE ON ADJACENT PROPERTY TO THE LEFT OF YOURS ------------------------------------------------------------------------------------- 8/9/2023 - PREVIOUS INSPECTION NOTES 08/09/23 we need to have the FFE and culvert pipe elevation for the home on the left that is under construction that was once vacant. Left side of the survey is showing at the property line 28.20 flat for more than 20' and then 27.80 flat for more than 20' also. right side is showing 28.30 flat for more than 20' and then goes 28.10 to a 28.2 back to 28.1. Finished Floor Elevations (FFE): Final Survey must include the FFE of the subjectproperty as well as the FFE of any adjacent developed properties. (A) Adjacent driveway culverts and drainage features: Final Survey must include theinverts of adjacent developed property driveway culverts and any other drainage featureswithin 100 feet of the property lines. (A) Citation(s): A.Land Development Code Technical Manual, Section 300.01 (C)(3) Comment: 300.01(4,5,6) Sec 300.01(4,5,6) The tolerance along side lot lines is no more than 20 feet flat, with positive fall on each side.Positive fall is considered to be 0.10 feet in 20 feet.The minimum fall from the rear property line to the front is 0.50 feet 7/27/2023 - PREVIOUS INSPECTION NOTES NEED TO HAVE SOD DOWN WHEN THE FINAL SURVEY IS SHOT FROM THE SURVEYORS
ROW- FINAL SURVEY/GRADING CERTIFICATION 08/29/2023 APPROVED PFLANAGAN
Note: LOOKED AT THE WRONG SURVEY PASSED 8/29/2023 - PREVIOUS INSPECTION NOTES 1) Sec.300.01 (4,5,6) The tolerance along side lot lines is no more than 20 feet, with positive fall on each side. Positive fall is considered to be 0.10 feet in 20 feet ---------------------------------------------------------------------------------- 8/11/2023 - PREVIOUS INSPECTION NOTES 1) Sec.300.01 (4,5,6) The tolerance along side lot lines is no more than 20 feet, with positive fall on each side. Positive fall is considered to be 0.10 feet in 20 feet 2) NEED TO HAVE THE FFE ON ADJACENT PROPERTY TO THE LEFT OF YOURS ------------------------------------------------------------------------------------- 8/9/2023 - PREVIOUS INSPECTION NOTES 08/09/23 we need to have the FFE and culvert pipe elevation for the home on the left that is under construction that was once vacant. Left side of the survey is showing at the property line 28.20 flat for more than 20' and then 27.80 flat for more than 20' also. right side is showing 28.30 flat for more than 20' and then goes 28.10 to a 28.2 back to 28.1. Finished Floor Elevations (FFE): Final Survey must include the FFE of the subjectproperty as well as the FFE of any adjacent developed properties. (A) Adjacent driveway culverts and drainage features: Final Survey must include theinverts of adjacent developed property driveway culverts and any other drainage featureswithin 100 feet of the property lines. (A) Citation(s): A.Land Development Code Technical Manual, Section 300.01 (C)(3) Comment: 300.01(4,5,6) Sec 300.01(4,5,6) The tolerance along side lot lines is no more than 20 feet flat, with positive fall on each side.Positive fall is considered to be 0.10 feet in 20 feet.The minimum fall from the rear property line to the front is 0.50 feet 7/27/2023 - PREVIOUS INSPECTION NOTES NEED TO HAVE SOD DOWN WHEN THE FINAL SURVEY IS SHOT FROM THE SURVEYORS
ROW- FINAL SURVEY/GRADING CERTIFICATION 08/11/2023 Disapproved -FEE REQUIRED PFLANAGAN
Note: 1) Sec.300.01 (4,5,6) The tolerance along side lot lines is no more than 20 feet, with positive fall on each side. Positive fall is considered to be 0.10 feet in 20 feet 2) NEED TO HAVE THE FFE ON ADJACENT PROPERTY TO THE LEFT OF YOURS ------------------------------------------------------------------------------------- 8/9/2023 - PREVIOUS INSPECTION NOTES 08/09/23 we need to have the FFE and culvert pipe elevation for the home on the left that is under construction that was once vacant. Left side of the survey is showing at the property line 28.20 flat for more than 20' and then 27.80 flat for more than 20' also. right side is showing 28.30 flat for more than 20' and then goes 28.10 to a 28.2 back to 28.1. Finished Floor Elevations (FFE): Final Survey must include the FFE of the subjectproperty as well as the FFE of any adjacent developed properties. (A) Adjacent driveway culverts and drainage features: Final Survey must include theinverts of adjacent developed property driveway culverts and any other drainage featureswithin 100 feet of the property lines. (A) Citation(s): A.Land Development Code Technical Manual, Section 300.01 (C)(3) Comment: 300.01(4,5,6) Sec 300.01(4,5,6) The tolerance along side lot lines is no more than 20 feet flat, with positive fall on each side.Positive fall is considered to be 0.10 feet in 20 feet.The minimum fall from the rear property line to the front is 0.50 feet 7/27/2023 - PREVIOUS INSPECTION NOTES NEED TO HAVE SOD DOWN WHEN THE FINAL SURVEY IS SHOT FROM THE SURVEYORS
ROW- FINAL SURVEY/GRADING CERTIFICATION 08/09/2023 Disapproved - NO FEE FSLADISH
Note: 08/09/23 we need to have the FFE and culvert pipe elevation for the home on the left that is under construction that was once vacant. Left side of the survey is showing at the property line 28.20 flat for more than 20' and then 27.80 flat for more than 20' also. right side is showing 28.30 flat for more than 20' and then goes 28.10 to a 28.2 back to 28.1. Finished Floor Elevations (FFE): Final Survey must include the FFE of the subjectproperty as well as the FFE of any adjacent developed properties. (A) Adjacent driveway culverts and drainage features: Final Survey must include theinverts of adjacent developed property driveway culverts and any other drainage featureswithin 100 feet of the property lines. (A) Citation(s): A.Land Development Code Technical Manual, Section 300.01 (C)(3) Comment: 300.01(4,5,6) Sec 300.01(4,5,6) The tolerance along side lot lines is no more than 20 feet flat, with positive fall on each side.Positive fall is considered to be 0.10 feet in 20 feet.The minimum fall from the rear property line to the front is 0.50 feet 7/27/2023 - PREVIOUS INSPECTION NOTES NEED TO HAVE SOD DOWN WHEN THE FINAL SURVEY IS SHOT FROM THE SURVEYORS
ROW FIELD SURVEY /GRADING CERTIFICATION 08/09/2023 Disapproved - NO FEE FSLADISH
Note: 08/09/23 You must first pass the final survey before a field survey can be done.
ROW- FINAL SURVEY/GRADING CERTIFICATION 07/27/2023 Disapproved - NO FEE PFLANAGAN
Note: NEED TO HAVE SOD DOWN WHEN THE FINAL SURVEY IS SHOT FROM THE SURVEYORS
ROW- PRE-APRON (PRE-POUR) 07/12/2023 APPROVED - AS NOTED FSLADISH
Note: 07/12/23 SPOKE WITH CM, LET HIM KNOW I AM APPROVING AS NOTED. IT IS A LITTLE SOFT BUT SHOULD BE DRY ENOUGH TO POUR. TOLD HIM IT IS HIS RESPONSINILITY TO DOUBLE CHECK THE PIPE ELEVATION BEFORE POURING AND MAKE SURE ANY RESIDUAL WATER IS OUT OF THE MITERED END FOOTERS AND THE ARE MAINTAINED TO CITY SPECS. PIPE IS GOOD AT THE TIME OF THIS INSPECTION. THIS INSPECTION WAS FOR THE LEFT SIDE CULVERT PIPE ONLY. AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS BEFORE POURING. MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL ___________________________________________________________________________________________________________________________ 6/27/2023 - PREVIOUS INSPECTION NOTES PLEASE NOTE THAT THIS IS FOR THE RIGHT DRIVEWAY ONLY DO NOT POUR LEFT DRIVEWAY. IT'S YOUR RESPONSIBILITY TO CHECK THE CULVERT PIPE BEFORE POURING CONCRETE FOR DRIVEWAY. ALL CONCRETE NEED TO BE 3000PSI WITH FIBER OR METYAL MESH TO MEET CITY'S STANDARTS. At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved.
ELECTRIC - EARLY POWER 07/12/2023 APPROVED - AS NOTED JWALKER
Note: 7/12/23 CHECK FOR CORRECT REVISION OF THE ELECTRICAL RISER AT FINAL BUILDING INSPECTION. ENSURE THE REVISION IS APPROVED AND MATCHES THE AS BULIT ELECTRCIAL RISER INSTALLED. 7/11/2023 - PREVIOUS INSPECTION NOTES 7/11/23 Riser diagram submitted 7/10/23 to the building department has not yet been approved. It also does not appear to match the electrical riser installed. 7/10/2023 - PREVIOUS INSPECTION NOTES 1. The electrical riser diagram does not match the installed electrical riser diagram. Please have the engineer submitt a revision to the building department showing the as built riser.
ELECTRIC - EARLY POWER 07/11/2023 Disapproved -FEE REQUIRED JWALKER
Note: 7/11/23 Riser diagram submitted 7/10/23 to the building department has not yet been approved. It also does not appear to match the electrical riser installed. 7/10/2023 - PREVIOUS INSPECTION NOTES 1. The electrical riser diagram does not match the installed electrical riser diagram. Please have the engineer submitt a revision to the building department showing the as built riser.
ELECTRIC - EARLY POWER 07/10/2023 Disapproved - NO FEE JWALKER
Note: 1. The electrical riser diagram does not match the installed electrical riser diagram. Please have the engineer submitt a revision to the building department showing the as built riser.
GRAVITY SEWER TEST 07/06/2023 APPROVED MGIBSON
U - SEWER TIE IN 07/06/2023 APPROVED MGIBSON
ROW- PRE-APRON (PRE-POUR) 06/27/2023 PARTIALLY APPROVED PFLANAGAN
Note: PLEASE NOTE THAT THIS IS FOR THE RIGHT DRIVEWAY ONLY DO NOT POUR LEFT DRIVEWAY. IT'S YOUR RESPONSIBILITY TO CHECK THE CULVERT PIPE BEFORE POURING CONCRETE FOR DRIVEWAY. ALL CONCRETE NEED TO BE 3000PSI WITH FIBER OR METYAL MESH TO MEET CITY'S STANDARTS. At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved.
PEP TANK INSTALLATION REQUEST 06/23/2023 APPROVED CSTONE
Note: 6/2/2023 4:24:20 PM- PREVIOUS INSPECTION NOTES exterior not complete and temp power in the way
LATH/BRICK/ WATER BARRIER 06/06/2023 APPROVED JWALKER
WINDOW NAILING 06/06/2023 Disapproved - NO FEE JWALKER
Note: 6/6/23 Rear window and bathroom window for Unit B not installed. Product approval stickers not on the front doors, rear doors, or windows. Please provide product approval labels. Inspection for rear sliders, rear doors and front doors.
PEP TANK INSTALLATION REQUEST 06/02/2023 CANCELLED BY APPLICANT WEB
PEP TANK INSTALLATION REQUEST 06/01/2023 Disapproved - NO FEE CSTONE
Note: exterior not complete and temp power in the way
INSULATION 06/01/2023 APPROVED BTAYLOR
Note: 5/30/2023 - PREVIOUS INSPECTION NOTES duct layout still not matching approved drawings (there is an unapproved duct drawing on site FYI, it does not match the ductwork iether). Several top plate holes missing fire foam (check all) Inspector Notes from Inspection 2420 1.Check for approved duct layout at insulation inspection as the drawings have only been accepted. 2. Inspector adding window nailing inspection for rear sliders,,rear door and front doors. Contractor has sealed the openings and may insulate. 5/22/2023 - PREVIOUS INSPECTION NOTES 1. Both A and B Units the hvac AHU locations have been changed from the garage attic area to above the livings space of the house. Please submitt a revison to the building department showing the new locations. Include attic access also. 2. Horizontal plumbing vents are to be sloped downward toward the drain and supported at 4' o.c. 3. Unit A the UFB line to the kitchen kneewall has not been installed. 4. Rear sliders and rear doors have not been installed. 5. Seal the floor in Unit B kitchen at the UFB line. 6. Front entry doors are not installed.
INSULATION 05/30/2023 Disapproved - NO FEE LMILLER
Note: duct layout still not matching approved drawings (there is an unapproved duct drawing on site FYI, it does not match the ductwork iether). Several top plate holes missing fire foam (check all) Inspector Notes from Inspection 2420 1.Check for approved duct layout at insulation inspection as the drawings have only been accepted. 2. Inspector adding window nailing inspection for rear sliders,,rear door and front doors. Contractor has sealed the openings and may insulate. 5/22/2023 - PREVIOUS INSPECTION NOTES 1. Both A and B Units the hvac AHU locations have been changed from the garage attic area to above the livings space of the house. Please submitt a revison to the building department showing the new locations. Include attic access also. 2. Horizontal plumbing vents are to be sloped downward toward the drain and supported at 4' o.c. 3. Unit A the UFB line to the kitchen kneewall has not been installed. 4. Rear sliders and rear doors have not been installed. 5. Seal the floor in Unit B kitchen at the UFB line. 6. Front entry doors are not installed.
ALL ROUGH 05/23/2023 APPROVED - AS NOTED JWALKER
Note: 1.Check for approved duct layout at insulation inspection as the drawings have only been accepted. 2. Inspector adding window nailing inspection for rear sliders,,rear door and front doors. Contractor has sealed the openings and may insulate. 5/22/2023 - PREVIOUS INSPECTION NOTES 1. Both A and B Units the hvac AHU locations have been changed from the garage attic area to above the livings space of the house. Please submitt a revison to the building department showing the new locations. Include attic access also. 2. Horizontal plumbing vents are to be sloped downward toward the drain and supported at 4' o.c. 3. Unit A the UFB line to the kitchen kneewall has not been installed. 4. Rear sliders and rear doors have not been installed. 5. Seal the floor in Unit B kitchen at the UFB line. 6. Front entry doors are not installed.
ALL ROUGH 05/22/2023 Disapproved - NO FEE JWALKER
Note: 1. Both A and B Units the hvac AHU locations have been changed from the garage attic area to above the livings space of the house. Please submitt a revison to the building department showing the new locations. Include attic access also. 2. Horizontal plumbing vents are to be sloped downward toward the drain and supported at 4' o.c. 3. Unit A the UFB line to the kitchen kneewall has not been installed. 4. Rear sliders and rear doors have not been installed. 5. Seal the floor in Unit B kitchen at the UFB line. 6. Front entry doors are not installed.
ROOF VALLEY & METAL 05/10/2023 APPROVED BTAYLOR
Note: 5/5/2023 - PREVIOUS INSPECTION NOTES Area's of nailed roof sheating will need to be corrected before roof valley can pass. See Truss drawing circled locations that need to be corrected.
ROOF SHEATHING / BRACES/TIES/DOWN CELL 05/10/2023 APPROVED BTAYLOR
Note: 5/5/2023 - PREVIOUS INSPECTION NOTES 1. The LTTS20's at the garage bearing wall post not installed. 2. Please provide a truss drawing that is number and letter to match the engineering. 3. Truss engineering packet is out of order and possible missing pages. 4. The fire wall has not been constructed as per the detail of Sheet #2 of the prints. Knee wall has not been framed. Two truss are installed above the block. Please submitt a revison to the building department showing the change of firewall constuction. 5. Where the over framing ridges meet the truss decking install blocking between the trusses below and strap ridge to blocking. 6. Roof sheating has missed nailing in 3 locations the unnumber/letter truss drawing has been circled to provide locations needed corrected.
ROOF VALLEY & METAL 05/05/2023 Disapproved - NO FEE JWALKER
Note: Area's of nailed roof sheating will need to be corrected before roof valley can pass. See Truss drawing circled locations that need to be corrected.
WALL SHEATHING 05/05/2023 APPROVED JWALKER
ROOF SHEATHING / BRACES/TIES/DOWN CELL 05/05/2023 Disapproved - NO FEE JWALKER
Note: 1. The LTTS20's at the garage bearing wall post not installed. 2. Please provide a truss drawing that is number and letter to match the engineering. 3. Truss engineering packet is out of order and possible missing pages. 4. The fire wall has not been constructed as per the detail of Sheet #2 of the prints. Knee wall has not been framed. Two truss are installed above the block. Please submitt a revison to the building department showing the change of firewall constuction. 5. Where the over framing ridges meet the truss decking install blocking between the trusses below and strap ridge to blocking. 6. Roof sheating has missed nailing in 3 locations the unnumber/letter truss drawing has been circled to provide locations needed corrected.
FOUND SURVEY APPROVED (OFFICE) 05/04/2023 APPROVED AMOBLEY
ELEV CERT-FOUNDATION APPROVAL 05/02/2023 APPROVED AMOBLEY
TIE BEAM / LINTEL 04/11/2023 APPROVED FWILLIS
Note: 4/10/2023 - PREVIOUS INSPECTION NOTES need approved documents on site for inspection (documents on site are not approved) FBC 107.3
TIE BEAM / LINTEL 04/10/2023 Disapproved -FEE REQUIRED LMILLER
Note: need approved documents on site for inspection (documents on site are not approved) FBC 107.3
ELECTRIC TEMP POLE 04/05/2023 APPROVED JWALKER
MONOLITHIC SLAB 04/03/2023 APPROVED JWALKER
Note: 3/31/2023 - PREVIOUS INSPECTION NOTES Address number needs to be posted. Compaction test results of the slab need to be posted.
WATER METER INSTALLATION REQUEST 04/03/2023 APPROVED CSTONE
Note: 3/28/2023 10:55:01 AM- PREVIOUS INSPECTION NOTES not cleared rebar and block
MONOLITHIC SLAB 03/31/2023 Disapproved - NO FEE JWALKER
Note: Address number needs to be posted. Compaction test results of the slab need to be posted.
PLUMBING 1ST ROUGH UNDERGROUND 03/23/2023 APPROVED MGIBSON
WATER METER INSTALLATION REQUEST 03/23/2023 Disapproved - NO FEE CSTONE
Note: not cleared rebar and block

Review History

Department Status Date In Date Out
MECH COMPLETE 10/11/2023 10/11/2023
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
BLD COMPLETE 10/11/2023 10/11/2023
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
BADMIN INFORMATION 10/10/2023 10/10/2023
Note: Marked INFORMATION By: BARBIE BEMBRY - (386)986-3780 - BUILDINGDIVISION@PALMCOASTGOV.COM The foundation plan submitted is blank.
MECH HOLD 10/09/2023 10/10/2023
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM 1. Energy Calcs need to be signed by the owner/ owner agent below the preparer per R103.1.1.2 FBC Energy Conservation 2020 7Th edition 2. Block wall insulation on Energy calcs says R10. Origional calcs shows R4.1. Provide plans showing R10 or revise calcs to R4.1 Third request
BLD HOLD 10/09/2023 10/10/2023
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Plans and letter need to be digitally signed, sealed, and verifiable per F.S. 471.025
MECH HOLD 10/05/2023 10/05/2023
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM 1. Energy Calcs need to be signed by the owner/ owner agent below the preparer per R103.1.1.2 FBC Energy Conservation 2020 7Th edition 2. Block wall insulation on Energy calcs says R10. Origional calcs shows R4.1. Provide plans showing R10 or revise calcs to R4.1
MECH HOLD 10/05/2023 10/06/2023
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM 1. Energy Calcs need to be signed by the owner/ owner agent below the preparer per R103.1.1.2 FBC Energy Conservation 2020 7Th edition 2. Block wall insulation on Energy calcs says R10. Origional calcs shows R4.1. Provide plans showing R10 or revise calcs to R4.1 Second request
BLD HOLD 10/05/2023 10/06/2023
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Provide correct UL number for firewall detail UL U309 calls for 5/8 inch Type X not 1/2 inch. Plans also call out 4ft of 1/2 fire rated plywood on either side of firewall on roof deck. An inspection will be added to confirm the fire rated sheathing.
BADMIN INFORMATION 08/10/2023 08/10/2023
Note: Marked INFORMATION By: BARBIE BEMBRY - (386)986-3780 - BUILDINGDIVISION@PALMCOASTGOV.COM Please rename your file correctly - see the document submittal requirements on the permit portal page for instructions.
MECH COMPLETE 07/19/2023 07/20/2023
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
MECH HOLD 07/13/2023 07/14/2023
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Provide duct layout for both sides of duplex. The same document was submitted for both. Need correct garage orientation (Third Request)
ELEC COMPLETE 07/13/2023 07/14/2023
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
BADMIN INFORMATION 07/13/2023 07/13/2023
Note: Marked INFORMATION By: LIBBY MUSGROVE - - LMUSGROVE@PALMCOASTGOV.COM File name incorrect - Doc name and file name must match Example: site=site no extra names or numbers
MECH HOLD 07/10/2023 07/10/2023
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Provide duct layout for both sides of duplex. The same document was submitted for both. Need correct garage orientation (Second Request)
ELEC HOLD 07/10/2023 07/13/2023
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. This is not a duplex riser digram. Submit exactly what was installed.
MECH HOLD 06/03/2023 06/05/2023
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Provide duct layout for both sides of duplex. The same document was submitted for both. Need correct garage orientation
BLD COMPLETE 06/03/2023 06/05/2023
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
ELEC COMPLETE 06/03/2023 06/05/2023
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
MECH HOLD 05/31/2023 05/31/2023
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM PARTIAL REPEAT COMMENT: Provide revised floor plan showing service outlet. Provide notes showing details in compliance with M1305.1.3
MECH HOLD 05/31/2023 06/01/2023
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM PARTIAL REPEAT COMMENT: Provide revised floor plan showing service outlet. Provide notes showing details in compliance with M1305.1.3 Provide duct layout for each side with correct garage orientation
MECH HOLD 05/23/2023 05/23/2023
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Provide revised floor plan showing new attic access location and service outlet with light. Provide notes showing details in compliance with M1305.1.3
ENGIN1 COMPLETE 05/02/2023 05/02/2023
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON COMPLETE 05/02/2023 05/02/2023
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
BLD COMPLETE 04/17/2023 04/21/2023
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
BLD COMPLETE 04/12/2023 04/14/2023
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ELEC COMPLETE 04/12/2023 04/14/2023
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
BLD COMPLETE 03/30/2023 04/03/2023
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
BLD COMPLETE 03/22/2023 03/27/2023
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ZON COMPLETE 11/01/2022 11/01/2022
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
BADMIN INFORMATION 11/01/2022 11/01/2022
Note: Marked INFORMATION By: MARGA DEFREITAS - - MDEFREITAS@PALMCOASTGOV.COM YOU HAVE NOT SUBMITTED THE LANDSCAPE I DONT SEE IN THE ATTACHEMENTS JUST THE REVISION
SWALE COMPLETE 10/25/2022 03/02/2023
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
BLD COMPLETE 10/24/2022 10/26/2022
Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM
CUSVC COMPLETE 10/24/2022 10/27/2022
Note: Released By: LISA ASBILL - - lasbill@palmcoastgov.com
ELEC COMPLETE 10/24/2022 10/25/2022
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ENGIN1 COMPLETE 10/24/2022 10/25/2022
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
LOCATE COMPLETE 10/24/2022 10/27/2022
Note: Released By: CANDACE STONE - - CSTONE@PALMCOASTGOV.COM
MECH COMPLETE 10/24/2022 10/25/2022
Note: Released By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM
SW1 COMPLETE 10/24/2022 11/01/2022
Note: Released By: ROBERT GROSS - (386)986-4769 - RGROSS@PALMCOASTGOV.COM
ZON HOLD 10/24/2022 10/25/2022
Note: Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM AC pad location do not match on plans,site and landscape plans Banding and stone must wrap both corners at least two foot

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
PLAN REVIEW - REVISION ¤97.50 10/12/2023
PLAN REVIEW - REVISION ¤32.50 10/12/2023
PLAN REVIEW - REVISION ¤32.50 10/12/2023
REINSPECTION RESIDENTIAL ¤40.00 10/12/2023
REINSPECTION RESIDENTIAL ¤40.00 10/12/2023
SW ENG REINSPECTION 20 ¤20.00 10/12/2023
SW ENG - REVIEW 20 ¤20.00 03/22/2023
SW ENG RES REVIEW 200 ¤200.00 03/22/2023
TRANS IMPACT FEE ADMIN ¤82.14 03/22/2023
TRANS IMPACT FEE ADMIN (¤82.14) 03/22/2023
SEWER CREDIT (¤1,806.00) 03/22/2023
SEWER INSPECTION ¤25.00 03/22/2023
SEWER CAPITAL FACILITY ¤10,689.64 03/22/2023
WATER CAPITAL FACILITY FEE ¤7,847.76 03/22/2023
SITE PLAN 30 ¤30.00 03/22/2023
WATER- TURN ON ¤50.00 03/22/2023
ADJUSTMENT 50% (¤721.00) 03/22/2023
ADMINISTRATIVE RESIDENTIAL ¤30.00 03/22/2023
INSPECTION - RESIDENTIAL ¤1,100.00 03/22/2023
PLAN REVIEW - RESIDENTIAL ¤312.00 03/22/2023
CONNECTION FEES ¤2,332.52 03/22/2023
FIRE IMPACT FEE ADMIN ¤25.23 03/22/2023
FIRE IMPACT FEE ADMIN (¤25.23) 03/22/2023
IMPACT FEE FIRE ¤841.04 03/22/2023
IMPACT FEE PARKS ¤3,538.30 03/22/2023
IMPACT FEE SCHOOL ¤10,900.00 03/22/2023
IMPACT FEE TRANSPORTATION ¤2,738.00 03/22/2023
WATER -IRRIGATION INSPECTION ¤50.00 03/22/2023
PARKS IMPACT FEE ADMIN ¤106.15 03/22/2023
PARKS IMPACT FEE ADMIN (¤106.15) 03/22/2023
SURCHARGE FS 533.721 ¤4.50 03/22/2023
SURCHARGE - FS 468.631 ¤6.75 03/22/2023
SW ENG - FOUNDATION SURVEY ¤20.00 03/22/2023
SW ENG INSPECTION 80 ¤80.00 03/22/2023
SW ENG PRE APRON ¤30.00 03/22/2023
Fees Total Due: ¤0.00 Total Paid: ¤38,581.01