Permit #2022101347
Permit Details
Status: EXPIRED
| Parcel Id: 07-11-31-7002-00010-0080 |
| CONDITIONED SPACE: 298 sqft |
| GARAGE: 640 sqft |
| OPENED PORCH (WITH ROOF) : 213 sqft |
| OPENED PORCH (WITH ROOF) : 213 sqft |
| CONDITIONED SPACE: 1280 sqft |
| Total Square Footage: 2644 sqft |
| Block: 00010 |
| Subdivision: 2218 - SECTION 2-FLORIDA PARK |
| Job Phone: 386-931-6577 |
| Location Address: 15 FARRADAY LN |
| Type: BA - BUILDING ADDITION |
| Issue Date: 07/14/2023 |
| NOC: Unknown |
| Applicant name: LUIS JORGE MEDEIROS |
| Owner: MISZTAL JERZY & RENATA H&W |
|
Address 13 FARRADAY LANE PALM COAST, FL 32137 |
| Lot: 0080 |
| Contracted Stated Job Value: ¤150,000.00 |
| Job Description: FRONT ADDITION - 2 STORY LIVING / GARAGE |
| Type: CN |
Contractor
A PLUS HOME IMPROVEMENTS LLC
| Status | Location Address | State License Number | Phone |
| ACTIVE |
306 S RAILROAD ST BUNNELL, FL 32110 |
CRC1327024 (Exp: 08/31/2026) | 386-263-2167 |
Sub Contractors
DANIEL J LUSINSKI
| Status | Location Address | Mailing Address | State License Number | Phone |
| ACTIVE |
389 PALM COAST PARKWAY SW PALM COAST, FL 32137 |
#4 PALM COAST, FL 32137 |
CCC1330133 (Exp: 08/31/2026) | 386-338-7926 |
GLEN WILLIAM KEHLE
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
P. O. Box 353511 BUNNELL, FL 32110 |
CFC057241 (Exp: 08/31/2026) | (386) 447-4249 | (386) 437-8488 |
JOSEPH MOUAG
| Status | Location Address | State License Number | Phone |
| ACTIVE |
842 BANBURY DRIVE PORT ORANGE, FL 32129 |
EC13006957 (Exp: 08/31/2026) | 386-547-3722 |
SCOTT H STILLWELL
| Status | Location Address | State License Number | Phone |
| ACTIVE |
4500 US 1 UNIT 206 BUNNELL, FL 32110 |
CAC1819433 (Exp: 08/31/2026) | 386-864-4404 |
GLEN WILLIAM KEHLE
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
P. O. Box 353511 BUNNELL, FL 32110 |
CFC057241 (Exp: 08/31/2026) | (386) 447-4249 | (386) 437-8488 |
Inspection History
| Type | Request Date | Result | Inspector |
| GRAVITY SEWER TEST | 07/30/2025 | APPROVED - AS NOTED | MGIBSON |
| Note: WHERE EXISTING BUILDING DRAIN CONNECTS TO NEW BUILDING DRAIN LINE A C/O IS REQUIRED ON OUTSIDE OF HOME 18 '' FROM FOUNDATION FOR RODDING | |||
| SEWER TIE IN | 07/30/2025 | APPROVED | MGIBSON |
| INSULATION | 05/27/2025 | APPROVED | HCAMACHO |
| Note: | |||
| ALL ROUGH | 05/01/2025 | APPROVED - AS NOTED | HCAMACHO |
| Note: 1. No 5' head on plumbing. 2. Need Linear test on shower upstairs. 3. Missing several nail plates on Electrical. Went over with builder. | |||
| ALL ROUGH | 04/30/2025 | CANCELLED BY APPLICANT | HCAMACHO |
| Note: Canceled via text. 3/27/2025 - PREVIOUS INSPECTION NOTES 1. Need to revise Electrical plan for the whole house including existing house. Outlets and switches were added in the existing house. 2. Need electrical plan for new bathroom and utility room upstairs. 3. Need service Riser plan, showing new service and location. 4. Service is not Grounded. 5. Using wrong nail plates to protect wires. 6. Missing outlets in several areas for the 6' rule from doors. 7. No 5' head on plumbing. 8. Water service not connected and no pressure on the lines. 9. Sliders are missing screws. Check all. 10.A/C needs to be checked. No plans or energy calcs on site. 11.Show all new work on plans to existing house. 12. All exhaust needs to go outside of house. Check right side of the house on wall. 13.Fire blocking missing in bath room upstairs, pantry and living room wall. 14. House to garage door needs screws. | |||
| ALL ROUGH | 03/27/2025 | Disapproved - NO FEE | HCAMACHO |
| Note: 1. Need to revise Electrical plan for the whole house including existing house. Outlets and switches were added in the existing house. 2. Need electrical plan for new bathroom and utility room upstairs. 3. Need service Riser plan, showing new service and location. 4. Service is not Grounded. 5. Using wrong nail plates to protect wires. 6. Missing outlets in several areas for the 6' rule from doors. 7. No 5' head on plumbing. 8. Water service not connected and no pressure on the lines. 9. Sliders are missing screws. Check all. 10.A/C needs to be checked. No plans or energy calcs on site. 11.Show all new work on plans to existing house. 12. All exhaust needs to go outside of house. Check right side of the house on wall. 13.Fire blocking missing in bath room upstairs, pantry and living room wall. 14. House to garage door needs screws. | |||
| ALL ROUGH | 03/18/2025 | CANCELLED BY APPLICANT | HCAMACHO |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 03/04/2025 | APPROVED | HCAMACHO |
| Note: | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 02/27/2025 | Disapproved - NO FEE | HCAMACHO |
| Note: 1. New Roof Extension is missing connectors to exhisting roof. The top is straped but not the bottom. 2. Exhisting trusses on part of the exhisting house in the bedroom were cut and modified. Needs Eng. with approved Revision. Note - Ok to cover other connections with playwood and wrap. | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 02/21/2025 | Disapproved - NO FEE | HCAMACHO |
| Note: 1. FGR01 has no connection on bearing points, uplift over 14,000, See new revision for connector. Marked. 2. Wall sitting on top of FGR01 has no connections. See detail Plan marked. 3. Wall over garage for front balcony 2nd floor missing attachemnts. See detail Plan, marked 4. All Thread missing on second floor. Marked.See Plan 5. Some Threaded rods are loose, check all. 6.Wall Framing at entry carrying Entry roof is missing conections at bottom. 7. New Roof Extension is missing connectors to exhisting roof. The top is straped but not the bottom. 8. Side Headers on the rear balcony, front balcony and rear porch that tie back to the house don't have any connectors. 9. Exhisting trusses on part of the exhisting house in the bedroom were cut and modified. Needs Eng. with approved Revision. | |||
| WATER METER INSTALLATION REQUEST | 01/17/2025 | ||
| FOOTER | 12/20/2024 | APPROVED | HCAMACHO |
| Note: Right Front Only | |||
| ROOF VALLEY & METAL | 10/21/2024 | APPROVED | HCAMACHO |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 10/18/2024 | Disapproved -FEE REQUIRED | HCAMACHO |
| Note: 1. Need approved correct set of plans.FBC [A]107.3.1 NEEDS APPROVED PLANS ON SITE 2. No connector shedule, can not verify type of attachments. 3. Using all thread to secure walls, not detail available. 4. Rear wall where big opening missing attachments on wall. 5. Framed wall on right side over block wall with trusses on top. Wall is covered can not see attachemnts, and trusses are also missing attachemnts. 6. Trusses over small closet in second floor missing connections. 7. Wall sitting on top of FGR01 has no connections. Need detail. 8. Wall over garage for front balcony missing attachemnts. 9. Plans on site show additional structure in rear, currently not present. 10. FGR01 has no connection on bearing points, uplift over 14,000. 11. Front wall entry has no connections. 12. No address posted 13. Need temporary railings on all balconys. 14. Could not verify all because did not have correct plans. 15. Roof sheating Ok. Very all at next inspection | |||
| WALL SHEATHING | 10/16/2024 | APPROVED | KSANDOE |
| Note: 9/17/2024 - PREVIOUS INSPECTION NOTES 1. Wall sheathing missing on front and back of home | |||
| WALL SHEATHING | 09/17/2024 | Disapproved - NO FEE | MKRASKI |
| Note: 1. Wall sheathing missing on front and back of home | |||
| FOOTER | 05/10/2024 | APPROVED | LMILLER |
| Note: 5-10-24 notes below resolved 4/2/2024 - PREVIOUS INSPECTION NOTES 1. The footing area at the front entry states existing on the prints. No footing detail is shown on the plans for this area. Please have the engineering submit a revision to the building department showing type of footing to be installed. at the front entry area. 2. As noted on several past projects. Please have the plans in order. | |||
| FOOTER | 04/02/2024 | Disapproved - NO FEE | JWALKER |
| Note: 1. The footing area at the front entry states existing on the prints. No footing detail is shown on the plans for this area. Please have the engineering submit a revision to the building department showing type of footing to be installed. at the front entry area. 2. As noted on several past projects. Please have the plans in order. | |||
| MONOLITHIC SLAB | 10/05/2023 | APPROVED | AGAETANO |
| PLUMBING 1ST ROUGH UNDERGROUND | 10/02/2023 | APPROVED | MGIBSON |
| DOWN CELL | |||
| BLD - BUILDING FINAL |
Review History
| Department | Status | Date In | Date Out |
| RSI | HOLD | 10/06/2025 | 10/06/2025 |
| Note: Held By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM DRIVEWAY CAN NOT BE IN THE 5' EASMENT YOU CANT HAVE GEO BRICK NEEDS TO HAVE RIGHT OF WAY | |||
| ZON | HOLD | 09/30/2025 | 09/30/2025 |
| Note: Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM New site plan shows pavers in right of way. Please provide a right of way agreement signed by owner and notarized. Once electronic copy is approved we will ask for original. | |||
| RSI | COMPLETE | 09/30/2025 | 09/30/2025 |
| Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM THIS IS FOR ONLY THE PROPOSED ADDITION | |||
| ENGIN1 | HOLD | 09/30/2025 | 10/06/2025 |
| Note: Held By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM - Driveway cannot be in the 5' easement - Geo-web is not allowed in the right of way Please feel free to call Parren if there are any questions or concerns. | |||
| SWALE | CANCEL | 09/12/2025 | |
| ZON | HOLD | 09/11/2025 | 09/11/2025 |
| Note: Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM REPEAT COMMENTS: Circular driveways cannot exceed 18ft in width. Circular driveway must be a circle. The layout you have now is not a circular. It is still squared off on left side and wider than 18ft. The entire circle driveway can only be max 18ft within the property lines. Circular Driveway must meet a 5ft setback on left side. | |||
| RSI | HOLD | 09/11/2025 | 09/15/2025 |
| Note: Held By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM DRIVEWAY CAN NOT BE IN THE 5' EASMENT | |||
| ENGIN1 | COMPLETE | 09/11/2025 | 09/12/2025 |
| Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM Type and size of culvert pipe to be installed must be indicated on plans | |||
| ENGIN1 | HOLD | 09/08/2025 | 09/08/2025 |
| Note: Held By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM Depict the driveway width at the property line (minimum 10 feet) and the edge of pavement (EOP) (minimum 16 feet). A driveway near an intersection on the same side as a stop sign must be a minimum of 65 feet from the intersection centerline to the flare of the driveway. Type and size of culvert pipe to be installed must be indicated on plans.Should there be a change in the type or size, the contractor must contact the City to revise the Swale Plan Diagram | |||
| SW1 | HOLD | 09/08/2025 | 09/08/2025 |
| Note: Held By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM Please revise driveway to meet COPC Standards per Technical Manual: Section 300.01A.1.c.(1): Depict the driveway width at the property line (minimum 10 feet) and the edge of pavement (EOP) (minimum 16 feet). A driveway near an intersection on the same side as a stop sign must be a minimum of 65 feet from the intersection centerline to the flare of the driveway. Type and size of culvert pipe to be installed must be indicated on plans.Should there be a change in the type or size, the contractor must contact the City to revise the Swale Plan Diagram | |||
| ZON | HOLD | 09/08/2025 | 09/08/2025 |
| Note: Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM Circular driveways cannot exceed 18ft in width. Circular driveway must be a circle. The layout you have now is not a circular Driveway must meet a 5ft setback. | |||
| MECH | COMPLETE | 05/19/2025 | 05/21/2025 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| BADMIN | INFORMATION | 05/19/2025 | 05/19/2025 |
| Note: Marked INFORMATION By: BARBIE BEMBRY - (386)986-3780 - BUILDINGDIVISION@PALMCOASTGOV.COM for future energy calc submittals, please upload the state card under the 'state card ' document type. | |||
| MECH | COMPLETE | 04/29/2025 | 04/30/2025 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 04/23/2025 | 04/24/2025 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 03/28/2025 | 03/31/2025 |
| Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM | |||
| BLD | HOLD | 03/25/2025 | 03/28/2025 |
| Note: Held By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM FL# 2087-R3 is not valid. | |||
| BLD | COMPLETE | 02/25/2025 | 03/03/2025 |
| Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 12/02/2024 | 12/09/2024 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| BLD | HOLD | 10/16/2024 | 10/23/2024 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM 1. Provide framing detail for new wood wall with parapet 2. Correct conflicting parapet wall detail to show one type of wall sheathing. Notes say 7/16 osb and 1/2 plywood | |||
| BLD | COMPLETE | 04/24/2024 | 04/29/2024 |
| Note: Released By: PATRICK BUCKLEY - (386)986-3786 - PBUCKLEY@PALMCOASTGOV.COM | |||
| BADMIN | INFORMATION | 04/04/2024 | 04/04/2024 |
| Note: Marked INFORMATION By: MICHELLE RAMOS - (386)986-3780 - MRAMOS@PALMCOASTGOV.COM Please fill out the extension form from the website. | |||
| BADMIN | INFORMATION | 09/26/2023 | 09/26/2023 |
| Note: Marked INFORMATION By: BARBIE BEMBRY - (386)986-3780 - BUILDINGDIVISION@PALMCOASTGOV.COM The description of improvement is missing from the NOC. Please correct and submit a re-recorded copy. | |||
| BADMIN | COMPLETE | 06/26/2023 | 06/26/2023 |
| Note: Released By: SCOTT THOMAS - - STHOMAS@PALMCOASTGOV.COM | |||
| BADMIN | HOLD | 03/13/2023 | 03/13/2023 |
| Note: Held By: BARBIE BEMBRY - (386)986-3780 - BUILDINGDIVISION@PALMCOASTGOV.COM This permit will require a licensed contractor to obtain the permit, the owner must reside at the property in order to obtain a permit as an owner/builder. (this is part of owner / builder disclosure Florida Statutes 489.103) | |||
| ZON | COMPLETE | 03/03/2023 | 03/03/2023 |
| Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM | |||
| ELEC | COMPLETE | 03/03/2023 | 03/03/2023 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 03/03/2023 | 03/10/2023 |
| Note: Released By: PATRICK BUCKLEY - (386)986-3786 - PBUCKLEY@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 03/03/2023 | 03/03/2023 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 03/03/2023 | 03/09/2023 |
| Note: Released By: ROBERT GROSS - (386)986-4769 - RGROSS@PALMCOASTGOV.COM See note in additional Information. Also see attachment for Accessory Structures information. | |||
| ELEC | HOLD | 02/17/2023 | 02/22/2023 |
| Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM Submit a riser diagram for the new service | |||
| ZON | HOLD | 02/17/2023 | 02/21/2023 |
| Note: Held By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM Repeat comment: the following request are still missing Site plan: missing Please show the demolition area along with the new covered porch. show material and dimensons of driveway. A/C equiptment in the encroaching in easement on left please add a/c equipment for the rear addition and make sure to include everything in landscape plan as they should match Rename the kitchen in porch area to summer kitchen Foundation plan: Please show the demolition area along with the new covered porch area Elevation plans : still missing 1. done 2 Rename the Elevation plans.. Left elevation should be labeled RIGHT and right elevation should be labeled LEFT. Landscape plan: will need to state there will be 9 total trees i see 8 trees drawn but only see 6 trees by name listed on the legend. Please clarify and list all nine. please make sure you add everyting that is on site plan to the landscape. Color sheet: roof is listed as shingles. Your blue prints list the new roof as metal please clarify. Also on the color sheet please list the colors of the garage | |||
| MECH | COMPLETE | 02/17/2023 | 02/21/2023 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| BLD | HOLD | 02/17/2023 | 02/27/2023 |
| Note: Held By: PATRICK BUCKLEY - (386)986-3786 - PBUCKLEY@PALMCOASTGOV.COM Plan Sheet 1/9 1. Provide design criteria for guards and guard infill components. 2. Provide note indicating no opening in guard shall allow passage of a 4 inch sphere. 3. Provide material, connections (between individual members) and fastening specifications for wood eve bracket detail. 4. Knee wall detail still does not indicate the lumber species to be used for construction - only the lumber grade is shown. 5. Provide material and attachment specifications for shutters above front entry. 6. Roof live load for Palm Coast is 20 p.s.f. minimum. Revise note from 15 p.s.f. to 20 p.s.f. Plan Sheet 3/9 1. This plan sheet contains elevations for a different building and conflicts with elevation views on other plan sheets. Please remove - it will not be reviewed. Plan Sheet 4/9 1. Provide specifications for girder beam between kitchen and great room. Provide details for supporting columns at each end. Where girder intersects exterior wall above existing sliding door, provide information on header above door and how the girder will interface there and framing details necessary to provide load path to foundation below. 2. Provide width of stairs in plan view. If winders are proposed at mid-point landing indicate risers and provide code compliant minimum dimensions . Winders do not constitute a landing. That means handrail shall be continuous and uninterrupted from very top of stairs at 2nd floor to very bottom at 1st floor. If you change to a landing, provide dimension of landing in direction of travel - equal or longer than width of stairs. 3. Provide clearances at toile in half-bath adjacent to stairs. Identify house / garage door as one of the types allowed in Section 4. Provide note in new garage area indicating garage slab to be sloped towards roll-up door openings to drain water. 5. Provide dimension of landing at exterior side of new garage personnel door. 6. Add not to new double leaf front entry door that glass in door shall be tempered glass per 7. Identify all appliances at proposed summer kitchen. What is item in counter top to the left of the sink. 8. Add note to rear covered porch that all 2" X 12" beam members will be continuous over two spans minimum. Add note indicating all splices / joints in individual 2"X12" members will occur over permanent column supports. 9. Add smoke detector locations to plans. Show smoke detectors in existing bedrooms and in rooms, hallways or areas in close proximity to each separate bedrooms. Add note that smoke detectors will be interconnected with new smoke detectors including those that will be provided in future attached addition that will be connected to home by breezeway. The addition to this home required existing smoke detectors throughout the home to be brought up to current code in conjunction with new smoke detectors. Add note indicating existing portions of the home subject to inspection for compliance at time of Final Building Inspection. 10. Add carbon monoxide alarms locations to plans. The proposed addition subjects the entire home, both existing areas and new areas to be provided with carbon monoxide alarms. Show locations in compliance with XXYY. Add note indicating existing portions of home subject to inspection for compliance at time of Final Building Inspection. 11. Correct roof slope on Roofing Worksheet. 5/2 is not a correct roof slope. 12. This plan sheet and Plan Sheet 7/9 indicate presence of winding stairs at stair midpoint. Stair section view indicates level landing. Please reconcile. Plan Sheet 1A/9: (Roof framing Detail Bonus Room): 1. Provide roof slope(s) for each roof section 2. Provide lumber species for rafters 3. Provide bearing detail for seat cut at rafter connections to walls. 4. Show ceiling joists including on-center spacing, lumber species and grade. 5. If no ceiling joists, then provide section view showing collar ties including size, lumber species and grade of collar ties, and fastening of ties to opposing rafters. 6. Plan indicates roof ridge beam, Ridge beams require column support at joints / splices and a load path or foundation. Provide required information. 7. Ridge beam is shown to be continuous through hipped roof to end bearing above porch beams. How is this possible? Please explain engineering design here. 8. Provide header schedule for 2nd floor window headers. Include lumber type, species and grade. 9. Provide lumber species and grade for hip beams. 10. Provide hip beam connection to ridge beams or provide framing details how hip beams will be supported 11. Provide eave framing detail. How will eaves be constructed? If using lookouts from rafter ends provide construction and attachment details for lookouts, soffit return framing, etc. 12. Provide rafter ends lateral support. How will rafters be prevented from rotating at ends above bearing walls? Breezeway: 1. Provide same information as noted above for complete breezeway roof framing. 2. How are breezeway beams supported at connections to home and detached building? How about attachment at columns at change of direction. Plan Sheet 8/9 Typical 2-Story Frame Wall Section. 1. Show insulation type and R value in wall section. 2. Show type of interior side (warm in winter) vapor barrier 3. All lumber references shall include wood species in addition to lumber grade. Wood species not shown in multiple locations. 4. Elevation views and roofing worksheet indicates asphalt shingles. This detail indicates metal ribbed roof. Please reconcile. 5. Plan Sheet 1.a/9 indicates 2" X 8" rafters at 24 inches on-center. This detail indicates rafters at 16 inches on-center. Please reconcile. 6. Provide lumber type, species and grade for ceiling joists. Provide connection details for ceiling joists to rafters. 7. Provide rafter seat cut to wall top plate detail. If necessary provide eave look-out detail. 8. Provide closure detail for rafter ends - rafters require solid blocking or other materials to prevent rafters from rolling under loaded conditions. 9. Indicate location of required draft stops in 2nd floor framing 10. Indicate band or rim joist at ends of second floor - floor trusses. Typical Balcony Framing Cross Section 1. Provide ledger and attachment details for porch roof rafter connections to roof. 2. Roofing worksheet indicates asphalt shingles. This detail indicates metal roof. Please reconcile. 3. Provide lumber type, species and grade for ceiling joists. 4. Provide rafter seat cut to wall top plate detail. If necessary provide eave look-out detail. 5. Provide closure detail for rafter ends - rafters require solid blocking or other materials to prevent rafters from rolling under loaded conditions. 6. Provide lumber type, species and grade for structural wood columns. Plan Sheet 9/9 Typical Guard Rails Detail. 1. Identify bottom rail and top rail lumber type, grade and species. 2. Provide attachment details for guard balusters. 3. Fill in Section and page information for this detail. 4. Remove the word "or" from header description. Header type to include both lumber species (S.Y.P.) and Grade #2. It's not one or the other. Staircase Construction Detail: 1. Provide lumber type, species and grade for 2" X 12" stair stringers. 2. Provide attachment detail for stringers to second floor landing and mid-point landing. Stairs cannot simply be nailed. Framing anchors and / or connecting straps required. 3. Show stair design loads of 40 p.s.f and 300 pound concentrated load on stair treads. 4. Provide tread materials 5. Provide floor sheathing type at mid-point landing 6. How will mid-point landing be supported on the side opposite its connection with the concrete wall? 7. Provide dimension of landing in direction of travel. 8. Stair section to include minimum headroom to lowest obstruction above - show it. 9. Show framing / furring and insulation at concrete wall. Frame Side Attachment: 1. Show Section and Plan Sheet number for where this detail is referenced. Roof Sheathing Detail: 1. Provide Section and Plan Sheet number where this detail is referenced. 2. Show correct roofing underlayment and roof covering - Roofing worksheet and elevation views indicate different roofing materials than shown here. MAY NOT BE A COMPLETE LIST. NUMEROUS PLAN DEFICIENCIES. | |||
| SW1 | COMPLETE | 02/17/2023 | 02/28/2023 |
| Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM | |||
| PLFM | COMPLETE | 10/28/2022 | 10/28/2022 |
| Note: Released By: DAMARIS RAMIREZ - (386)986-3750 - DRAMIREZ@PALMCOASTGOV.COM According to the Site Plan submitted on 10/27/22 the structure does not fall within the SFHA, no elevation certificates will be required. | |||
| SW1 | COMPLETE | 10/27/2022 | 11/03/2022 |
| Note: Released By: ROBERT GROSS - (386)986-4769 - RGROSS@PALMCOASTGOV.COM | |||
| BLD | HOLD | 10/26/2022 | 10/31/2022 |
| Note: Held By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM All comments below per the 2020 Florida Building Code PLAN REVIEW COMMENTS: 1. Provide all proposed elevations for review. [A]107.2.1. 2. Elevations submitted on sheet 1/9 are incorrectly noted. Revise the elevations to show the correct elevations. 3. Provide Details to how the proposed Breeze Way is to be constructed. Double 2 x 12 is called out with 4 x 4 post. Provide Footing to post connector, post to beam connector and beam to roofing connector. 4. Various call outs throughout the drawing reference #2 species. Provide the species of lumber to be used. 5. Provide a roof framing plan. 107.2.1. 6. Provide under stair protection per R302.7. | |||
| ELEC | HOLD | 10/26/2022 | 10/27/2022 |
| Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Need to show the existing size of the electrical service. 2. Need to submit electric load calcs showing the new added living space and prove the existing service can accommodate the added loads. | |||
| MECH | HOLD | 10/26/2022 | 10/28/2022 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Plans show R13 in wood frame walls. Energy Calcs say R19 and block with R5. Revise to match | |||
| PLUM | COMPLETE | 10/26/2022 | 10/31/2022 |
| Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM | |||
| ZON | HOLD | 10/26/2022 | 10/28/2022 |
| Note: Held By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM This project will be separated into two separate permits one for the home remodel to the existing home, and one for the proposed addition in the rear. The pool is not included in either one of these permits. This has already been taken care of with the building dept. permit numbers are as follows 2022101347 and 2022101411 Please apply for a pool permit separately. Pool needs to be labeled on site plan as future pool. Please also note it will need to be submitted on a seperate permi Site plan: missing Please show the demolition area along with the new covered porch. show material and dimensons of driveway. add A/C equiptment in the encroaching in easement on left please add a/c equipment for the rear addition and make sure to include everything in landscape plan as they should match Rename the kitchen in porch area to summer kitchen Foundation plan: Please show the demolition area along with the new covered porch area Elevation plans : 1.Height of entire home all the way to peak of new roof on the left side of the home where the bonus room is being added. 2 Rename the Elevation plans.. Left elevation should be labeled RIGHT and right elevation should be labeled LEFT. Landscape plan: will need to state there will be 9 total trees i see 8 trees drawn but only see 6 trees by name listed on the legend. Please clarify and list all nine. please make sure you add everyting that is on site plan to the landscape. Color sheet: roof is listed as shingles. Your blue prints list the new roof as metal please clarify. Also on the color sheet please list the colors of the garage | |||
| RSI | CANCEL | ||
| ZON | CANCEL | ||
| ENGIN1 | CANCEL |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| ADJUSTMENT 50% | (¤401.54) | 07/14/2023 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 07/14/2023 |
| INSPECTION - RESIDENTIAL | ¤602.25 | 07/14/2023 |
| PLAN REVIEW - RESIDENTIAL | ¤170.82 | 07/14/2023 |
| CONTRACTOR CHANGE | ¤20.00 | 07/14/2023 |
| CONTRACTOR CHANGE | ¤20.00 | 07/14/2023 |
| RECORDING FEE REIMBURSE DOC | ¤35.50 | 07/14/2023 |
| SURCHARGE FS 533.721 | ¤4.02 | 07/14/2023 |
| SURCHARGE - FS 468.631 | ¤6.02 | 07/14/2023 |
| SITE PLAN 30 | ¤30.00 | 07/14/2023 |
| CONTRACTOR CHANGE | ¤20.00 | |
| CONTRACTOR CHANGE | ¤20.00 | |
| PLAN REVIEW - REVISION | ¤32.50 | |
| REINSPECTION RESIDENTIAL | ¤40.00 | |
| CONTRACTOR CHANGE | ¤20.00 | |
| CONTRACTOR CHANGE | ¤20.00 | |
| Fees | Total Due: ¤152.50 | Total Paid: ¤517.07 |