Permit #2022101347

Permit Details

Status: EXPIRED

Parcel Id: 07-11-31-7002-00010-0080
CONDITIONED SPACE: 298 sqft
GARAGE: 640 sqft
OPENED PORCH (WITH ROOF) : 213 sqft
OPENED PORCH (WITH ROOF) : 213 sqft
CONDITIONED SPACE: 1280 sqft
Total Square Footage: 2644 sqft
Block: 00010
Subdivision: 2218 - SECTION 2-FLORIDA PARK
Job Phone: 386-931-6577
Location Address: 15 FARRADAY LN
Type: BA - BUILDING ADDITION
Issue Date: 07/14/2023
NOC: Unknown
Applicant name: LUIS JORGE MEDEIROS
Owner: MISZTAL JERZY & RENATA H&W

Address

13 FARRADAY LANE

PALM COAST, FL 32137

Lot: 0080
Contracted Stated Job Value: ¤150,000.00
Job Description: FRONT ADDITION - 2 STORY LIVING / GARAGE
Type: CN

Contractor

A PLUS HOME IMPROVEMENTS LLC
Status Location Address State License Number Phone
ACTIVE

306 S RAILROAD ST

BUNNELL, FL 32110

CRC1327024 (Exp: 08/31/2026) 386-263-2167

Sub Contractors

DANIEL J LUSINSKI
Status Location Address Mailing Address State License Number Phone
ACTIVE

389 PALM COAST PARKWAY SW

PALM COAST, FL 32137

#4

PALM COAST, FL 32137

CCC1330133 (Exp: 08/31/2026) 386-338-7926
GLEN WILLIAM KEHLE
Status Location Address State License Number Phone Fax
ACTIVE

P. O. Box 353511

BUNNELL, FL 32110

CFC057241 (Exp: 08/31/2026) (386) 447-4249 (386) 437-8488
JOSEPH MOUAG
Status Location Address State License Number Phone
ACTIVE

842 BANBURY DRIVE

PORT ORANGE, FL 32129

EC13006957 (Exp: 08/31/2026) 386-547-3722
SCOTT H STILLWELL
Status Location Address State License Number Phone
ACTIVE

4500 US 1 UNIT 206

BUNNELL, FL 32110

CAC1819433 (Exp: 08/31/2026) 386-864-4404
GLEN WILLIAM KEHLE
Status Location Address State License Number Phone Fax
ACTIVE

P. O. Box 353511

BUNNELL, FL 32110

CFC057241 (Exp: 08/31/2026) (386) 447-4249 (386) 437-8488

Inspection History

Type Request Date Result Inspector
GRAVITY SEWER TEST 07/30/2025 APPROVED - AS NOTED MGIBSON
Note: WHERE EXISTING BUILDING DRAIN CONNECTS TO NEW BUILDING DRAIN LINE A C/O IS REQUIRED ON OUTSIDE OF HOME 18 '' FROM FOUNDATION FOR RODDING
SEWER TIE IN 07/30/2025 APPROVED MGIBSON
INSULATION 05/27/2025 APPROVED HCAMACHO
Note:
ALL ROUGH 05/01/2025 APPROVED - AS NOTED HCAMACHO
Note: 1. No 5' head on plumbing. 2. Need Linear test on shower upstairs. 3. Missing several nail plates on Electrical. Went over with builder.
ALL ROUGH 04/30/2025 CANCELLED BY APPLICANT HCAMACHO
Note: Canceled via text. 3/27/2025 - PREVIOUS INSPECTION NOTES 1. Need to revise Electrical plan for the whole house including existing house. Outlets and switches were added in the existing house. 2. Need electrical plan for new bathroom and utility room upstairs. 3. Need service Riser plan, showing new service and location. 4. Service is not Grounded. 5. Using wrong nail plates to protect wires. 6. Missing outlets in several areas for the 6' rule from doors. 7. No 5' head on plumbing. 8. Water service not connected and no pressure on the lines. 9. Sliders are missing screws. Check all. 10.A/C needs to be checked. No plans or energy calcs on site. 11.Show all new work on plans to existing house. 12. All exhaust needs to go outside of house. Check right side of the house on wall. 13.Fire blocking missing in bath room upstairs, pantry and living room wall. 14. House to garage door needs screws.
ALL ROUGH 03/27/2025 Disapproved - NO FEE HCAMACHO
Note: 1. Need to revise Electrical plan for the whole house including existing house. Outlets and switches were added in the existing house. 2. Need electrical plan for new bathroom and utility room upstairs. 3. Need service Riser plan, showing new service and location. 4. Service is not Grounded. 5. Using wrong nail plates to protect wires. 6. Missing outlets in several areas for the 6' rule from doors. 7. No 5' head on plumbing. 8. Water service not connected and no pressure on the lines. 9. Sliders are missing screws. Check all. 10.A/C needs to be checked. No plans or energy calcs on site. 11.Show all new work on plans to existing house. 12. All exhaust needs to go outside of house. Check right side of the house on wall. 13.Fire blocking missing in bath room upstairs, pantry and living room wall. 14. House to garage door needs screws.
ALL ROUGH 03/18/2025 CANCELLED BY APPLICANT HCAMACHO
ROOF SHEATHING / BRACES/TIES/DOWN CELL 03/04/2025 APPROVED HCAMACHO
Note:
ROOF SHEATHING / BRACES/TIES/DOWN CELL 02/27/2025 Disapproved - NO FEE HCAMACHO
Note: 1. New Roof Extension is missing connectors to exhisting roof. The top is straped but not the bottom. 2. Exhisting trusses on part of the exhisting house in the bedroom were cut and modified. Needs Eng. with approved Revision. Note - Ok to cover other connections with playwood and wrap.
ROOF SHEATHING / BRACES/TIES/DOWN CELL 02/21/2025 Disapproved - NO FEE HCAMACHO
Note: 1. FGR01 has no connection on bearing points, uplift over 14,000, See new revision for connector. Marked. 2. Wall sitting on top of FGR01 has no connections. See detail Plan marked. 3. Wall over garage for front balcony 2nd floor missing attachemnts. See detail Plan, marked 4. All Thread missing on second floor. Marked.See Plan 5. Some Threaded rods are loose, check all. 6.Wall Framing at entry carrying Entry roof is missing conections at bottom. 7. New Roof Extension is missing connectors to exhisting roof. The top is straped but not the bottom. 8. Side Headers on the rear balcony, front balcony and rear porch that tie back to the house don't have any connectors. 9. Exhisting trusses on part of the exhisting house in the bedroom were cut and modified. Needs Eng. with approved Revision.
WATER METER INSTALLATION REQUEST 01/17/2025
FOOTER 12/20/2024 APPROVED HCAMACHO
Note: Right Front Only
ROOF VALLEY & METAL 10/21/2024 APPROVED HCAMACHO
ROOF SHEATHING / BRACES/TIES/DOWN CELL 10/18/2024 Disapproved -FEE REQUIRED HCAMACHO
Note: 1. Need approved correct set of plans.FBC [A]107.3.1 NEEDS APPROVED PLANS ON SITE 2. No connector shedule, can not verify type of attachments. 3. Using all thread to secure walls, not detail available. 4. Rear wall where big opening missing attachments on wall. 5. Framed wall on right side over block wall with trusses on top. Wall is covered can not see attachemnts, and trusses are also missing attachemnts. 6. Trusses over small closet in second floor missing connections. 7. Wall sitting on top of FGR01 has no connections. Need detail. 8. Wall over garage for front balcony missing attachemnts. 9. Plans on site show additional structure in rear, currently not present. 10. FGR01 has no connection on bearing points, uplift over 14,000. 11. Front wall entry has no connections. 12. No address posted 13. Need temporary railings on all balconys. 14. Could not verify all because did not have correct plans. 15. Roof sheating Ok. Very all at next inspection
WALL SHEATHING 10/16/2024 APPROVED KSANDOE
Note: 9/17/2024 - PREVIOUS INSPECTION NOTES 1. Wall sheathing missing on front and back of home
WALL SHEATHING 09/17/2024 Disapproved - NO FEE MKRASKI
Note: 1. Wall sheathing missing on front and back of home
FOOTER 05/10/2024 APPROVED LMILLER
Note: 5-10-24 notes below resolved 4/2/2024 - PREVIOUS INSPECTION NOTES 1. The footing area at the front entry states existing on the prints. No footing detail is shown on the plans for this area. Please have the engineering submit a revision to the building department showing type of footing to be installed. at the front entry area. 2. As noted on several past projects. Please have the plans in order.
FOOTER 04/02/2024 Disapproved - NO FEE JWALKER
Note: 1. The footing area at the front entry states existing on the prints. No footing detail is shown on the plans for this area. Please have the engineering submit a revision to the building department showing type of footing to be installed. at the front entry area. 2. As noted on several past projects. Please have the plans in order.
MONOLITHIC SLAB 10/05/2023 APPROVED AGAETANO
PLUMBING 1ST ROUGH UNDERGROUND 10/02/2023 APPROVED MGIBSON
DOWN CELL
BLD - BUILDING FINAL

Review History

Department Status Date In Date Out
RSI HOLD 10/06/2025 10/06/2025
Note: Held By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM DRIVEWAY CAN NOT BE IN THE 5' EASMENT YOU CANT HAVE GEO BRICK NEEDS TO HAVE RIGHT OF WAY
ZON HOLD 09/30/2025 09/30/2025
Note: Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM New site plan shows pavers in right of way. Please provide a right of way agreement signed by owner and notarized. Once electronic copy is approved we will ask for original.
RSI COMPLETE 09/30/2025 09/30/2025
Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM THIS IS FOR ONLY THE PROPOSED ADDITION
ENGIN1 HOLD 09/30/2025 10/06/2025
Note: Held By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM - Driveway cannot be in the 5' easement - Geo-web is not allowed in the right of way Please feel free to call Parren if there are any questions or concerns.
SWALE CANCEL 09/12/2025
ZON HOLD 09/11/2025 09/11/2025
Note: Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM REPEAT COMMENTS: Circular driveways cannot exceed 18ft in width. Circular driveway must be a circle. The layout you have now is not a circular. It is still squared off on left side and wider than 18ft. The entire circle driveway can only be max 18ft within the property lines. Circular Driveway must meet a 5ft setback on left side.
RSI HOLD 09/11/2025 09/15/2025
Note: Held By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM DRIVEWAY CAN NOT BE IN THE 5' EASMENT
ENGIN1 COMPLETE 09/11/2025 09/12/2025
Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM Type and size of culvert pipe to be installed must be indicated on plans
ENGIN1 HOLD 09/08/2025 09/08/2025
Note: Held By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM Depict the driveway width at the property line (minimum 10 feet) and the edge of pavement (EOP) (minimum 16 feet). A driveway near an intersection on the same side as a stop sign must be a minimum of 65 feet from the intersection centerline to the flare of the driveway. Type and size of culvert pipe to be installed must be indicated on plans.Should there be a change in the type or size, the contractor must contact the City to revise the Swale Plan Diagram
SW1 HOLD 09/08/2025 09/08/2025
Note: Held By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM Please revise driveway to meet COPC Standards per Technical Manual: Section 300.01A.1.c.(1): Depict the driveway width at the property line (minimum 10 feet) and the edge of pavement (EOP) (minimum 16 feet). A driveway near an intersection on the same side as a stop sign must be a minimum of 65 feet from the intersection centerline to the flare of the driveway. Type and size of culvert pipe to be installed must be indicated on plans.Should there be a change in the type or size, the contractor must contact the City to revise the Swale Plan Diagram
ZON HOLD 09/08/2025 09/08/2025
Note: Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM Circular driveways cannot exceed 18ft in width. Circular driveway must be a circle. The layout you have now is not a circular Driveway must meet a 5ft setback.
MECH COMPLETE 05/19/2025 05/21/2025
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
BADMIN INFORMATION 05/19/2025 05/19/2025
Note: Marked INFORMATION By: BARBIE BEMBRY - (386)986-3780 - BUILDINGDIVISION@PALMCOASTGOV.COM for future energy calc submittals, please upload the state card under the 'state card ' document type.
MECH COMPLETE 04/29/2025 04/30/2025
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
BLD COMPLETE 04/23/2025 04/24/2025
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
BLD COMPLETE 03/28/2025 03/31/2025
Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM
BLD HOLD 03/25/2025 03/28/2025
Note: Held By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM FL# 2087-R3 is not valid.
BLD COMPLETE 02/25/2025 03/03/2025
Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM
BLD COMPLETE 12/02/2024 12/09/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
BLD HOLD 10/16/2024 10/23/2024
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM 1. Provide framing detail for new wood wall with parapet 2. Correct conflicting parapet wall detail to show one type of wall sheathing. Notes say 7/16 osb and 1/2 plywood
BLD COMPLETE 04/24/2024 04/29/2024
Note: Released By: PATRICK BUCKLEY - (386)986-3786 - PBUCKLEY@PALMCOASTGOV.COM
BADMIN INFORMATION 04/04/2024 04/04/2024
Note: Marked INFORMATION By: MICHELLE RAMOS - (386)986-3780 - MRAMOS@PALMCOASTGOV.COM Please fill out the extension form from the website.
BADMIN INFORMATION 09/26/2023 09/26/2023
Note: Marked INFORMATION By: BARBIE BEMBRY - (386)986-3780 - BUILDINGDIVISION@PALMCOASTGOV.COM The description of improvement is missing from the NOC. Please correct and submit a re-recorded copy.
BADMIN COMPLETE 06/26/2023 06/26/2023
Note: Released By: SCOTT THOMAS - - STHOMAS@PALMCOASTGOV.COM
BADMIN HOLD 03/13/2023 03/13/2023
Note: Held By: BARBIE BEMBRY - (386)986-3780 - BUILDINGDIVISION@PALMCOASTGOV.COM This permit will require a licensed contractor to obtain the permit, the owner must reside at the property in order to obtain a permit as an owner/builder. (this is part of owner / builder disclosure Florida Statutes 489.103)
ZON COMPLETE 03/03/2023 03/03/2023
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
ELEC COMPLETE 03/03/2023 03/03/2023
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
BLD COMPLETE 03/03/2023 03/10/2023
Note: Released By: PATRICK BUCKLEY - (386)986-3786 - PBUCKLEY@PALMCOASTGOV.COM
ENGIN1 COMPLETE 03/03/2023 03/03/2023
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
SW1 COMPLETE 03/03/2023 03/09/2023
Note: Released By: ROBERT GROSS - (386)986-4769 - RGROSS@PALMCOASTGOV.COM See note in additional Information. Also see attachment for Accessory Structures information.
ELEC HOLD 02/17/2023 02/22/2023
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM Submit a riser diagram for the new service
ZON HOLD 02/17/2023 02/21/2023
Note: Held By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM Repeat comment: the following request are still missing Site plan: missing Please show the demolition area along with the new covered porch. show material and dimensons of driveway. A/C equiptment in the encroaching in easement on left please add a/c equipment for the rear addition and make sure to include everything in landscape plan as they should match Rename the kitchen in porch area to summer kitchen Foundation plan: Please show the demolition area along with the new covered porch area Elevation plans : still missing 1. done 2 Rename the Elevation plans.. Left elevation should be labeled RIGHT and right elevation should be labeled LEFT. Landscape plan: will need to state there will be 9 total trees i see 8 trees drawn but only see 6 trees by name listed on the legend. Please clarify and list all nine. please make sure you add everyting that is on site plan to the landscape. Color sheet: roof is listed as shingles. Your blue prints list the new roof as metal please clarify. Also on the color sheet please list the colors of the garage
MECH COMPLETE 02/17/2023 02/21/2023
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
BLD HOLD 02/17/2023 02/27/2023
Note: Held By: PATRICK BUCKLEY - (386)986-3786 - PBUCKLEY@PALMCOASTGOV.COM Plan Sheet 1/9 1. Provide design criteria for guards and guard infill components. 2. Provide note indicating no opening in guard shall allow passage of a 4 inch sphere. 3. Provide material, connections (between individual members) and fastening specifications for wood eve bracket detail. 4. Knee wall detail still does not indicate the lumber species to be used for construction - only the lumber grade is shown. 5. Provide material and attachment specifications for shutters above front entry. 6. Roof live load for Palm Coast is 20 p.s.f. minimum. Revise note from 15 p.s.f. to 20 p.s.f. Plan Sheet 3/9 1. This plan sheet contains elevations for a different building and conflicts with elevation views on other plan sheets. Please remove - it will not be reviewed. Plan Sheet 4/9 1. Provide specifications for girder beam between kitchen and great room. Provide details for supporting columns at each end. Where girder intersects exterior wall above existing sliding door, provide information on header above door and how the girder will interface there and framing details necessary to provide load path to foundation below. 2. Provide width of stairs in plan view. If winders are proposed at mid-point landing indicate risers and provide code compliant minimum dimensions . Winders do not constitute a landing. That means handrail shall be continuous and uninterrupted from very top of stairs at 2nd floor to very bottom at 1st floor. If you change to a landing, provide dimension of landing in direction of travel - equal or longer than width of stairs. 3. Provide clearances at toile in half-bath adjacent to stairs. Identify house / garage door as one of the types allowed in Section 4. Provide note in new garage area indicating garage slab to be sloped towards roll-up door openings to drain water. 5. Provide dimension of landing at exterior side of new garage personnel door. 6. Add not to new double leaf front entry door that glass in door shall be tempered glass per 7. Identify all appliances at proposed summer kitchen. What is item in counter top to the left of the sink. 8. Add note to rear covered porch that all 2" X 12" beam members will be continuous over two spans minimum. Add note indicating all splices / joints in individual 2"X12" members will occur over permanent column supports. 9. Add smoke detector locations to plans. Show smoke detectors in existing bedrooms and in rooms, hallways or areas in close proximity to each separate bedrooms. Add note that smoke detectors will be interconnected with new smoke detectors including those that will be provided in future attached addition that will be connected to home by breezeway. The addition to this home required existing smoke detectors throughout the home to be brought up to current code in conjunction with new smoke detectors. Add note indicating existing portions of the home subject to inspection for compliance at time of Final Building Inspection. 10. Add carbon monoxide alarms locations to plans. The proposed addition subjects the entire home, both existing areas and new areas to be provided with carbon monoxide alarms. Show locations in compliance with XXYY. Add note indicating existing portions of home subject to inspection for compliance at time of Final Building Inspection. 11. Correct roof slope on Roofing Worksheet. 5/2 is not a correct roof slope. 12. This plan sheet and Plan Sheet 7/9 indicate presence of winding stairs at stair midpoint. Stair section view indicates level landing. Please reconcile. Plan Sheet 1A/9: (Roof framing Detail Bonus Room): 1. Provide roof slope(s) for each roof section 2. Provide lumber species for rafters 3. Provide bearing detail for seat cut at rafter connections to walls. 4. Show ceiling joists including on-center spacing, lumber species and grade. 5. If no ceiling joists, then provide section view showing collar ties including size, lumber species and grade of collar ties, and fastening of ties to opposing rafters. 6. Plan indicates roof ridge beam, Ridge beams require column support at joints / splices and a load path or foundation. Provide required information. 7. Ridge beam is shown to be continuous through hipped roof to end bearing above porch beams. How is this possible? Please explain engineering design here. 8. Provide header schedule for 2nd floor window headers. Include lumber type, species and grade. 9. Provide lumber species and grade for hip beams. 10. Provide hip beam connection to ridge beams or provide framing details how hip beams will be supported 11. Provide eave framing detail. How will eaves be constructed? If using lookouts from rafter ends provide construction and attachment details for lookouts, soffit return framing, etc. 12. Provide rafter ends lateral support. How will rafters be prevented from rotating at ends above bearing walls? Breezeway: 1. Provide same information as noted above for complete breezeway roof framing. 2. How are breezeway beams supported at connections to home and detached building? How about attachment at columns at change of direction. Plan Sheet 8/9 Typical 2-Story Frame Wall Section. 1. Show insulation type and R value in wall section. 2. Show type of interior side (warm in winter) vapor barrier 3. All lumber references shall include wood species in addition to lumber grade. Wood species not shown in multiple locations. 4. Elevation views and roofing worksheet indicates asphalt shingles. This detail indicates metal ribbed roof. Please reconcile. 5. Plan Sheet 1.a/9 indicates 2" X 8" rafters at 24 inches on-center. This detail indicates rafters at 16 inches on-center. Please reconcile. 6. Provide lumber type, species and grade for ceiling joists. Provide connection details for ceiling joists to rafters. 7. Provide rafter seat cut to wall top plate detail. If necessary provide eave look-out detail. 8. Provide closure detail for rafter ends - rafters require solid blocking or other materials to prevent rafters from rolling under loaded conditions. 9. Indicate location of required draft stops in 2nd floor framing 10. Indicate band or rim joist at ends of second floor - floor trusses. Typical Balcony Framing Cross Section 1. Provide ledger and attachment details for porch roof rafter connections to roof. 2. Roofing worksheet indicates asphalt shingles. This detail indicates metal roof. Please reconcile. 3. Provide lumber type, species and grade for ceiling joists. 4. Provide rafter seat cut to wall top plate detail. If necessary provide eave look-out detail. 5. Provide closure detail for rafter ends - rafters require solid blocking or other materials to prevent rafters from rolling under loaded conditions. 6. Provide lumber type, species and grade for structural wood columns. Plan Sheet 9/9 Typical Guard Rails Detail. 1. Identify bottom rail and top rail lumber type, grade and species. 2. Provide attachment details for guard balusters. 3. Fill in Section and page information for this detail. 4. Remove the word "or" from header description. Header type to include both lumber species (S.Y.P.) and Grade #2. It's not one or the other. Staircase Construction Detail: 1. Provide lumber type, species and grade for 2" X 12" stair stringers. 2. Provide attachment detail for stringers to second floor landing and mid-point landing. Stairs cannot simply be nailed. Framing anchors and / or connecting straps required. 3. Show stair design loads of 40 p.s.f and 300 pound concentrated load on stair treads. 4. Provide tread materials 5. Provide floor sheathing type at mid-point landing 6. How will mid-point landing be supported on the side opposite its connection with the concrete wall? 7. Provide dimension of landing in direction of travel. 8. Stair section to include minimum headroom to lowest obstruction above - show it. 9. Show framing / furring and insulation at concrete wall. Frame Side Attachment: 1. Show Section and Plan Sheet number for where this detail is referenced. Roof Sheathing Detail: 1. Provide Section and Plan Sheet number where this detail is referenced. 2. Show correct roofing underlayment and roof covering - Roofing worksheet and elevation views indicate different roofing materials than shown here. MAY NOT BE A COMPLETE LIST. NUMEROUS PLAN DEFICIENCIES.
SW1 COMPLETE 02/17/2023 02/28/2023
Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM
PLFM COMPLETE 10/28/2022 10/28/2022
Note: Released By: DAMARIS RAMIREZ - (386)986-3750 - DRAMIREZ@PALMCOASTGOV.COM According to the Site Plan submitted on 10/27/22 the structure does not fall within the SFHA, no elevation certificates will be required.
SW1 COMPLETE 10/27/2022 11/03/2022
Note: Released By: ROBERT GROSS - (386)986-4769 - RGROSS@PALMCOASTGOV.COM
BLD HOLD 10/26/2022 10/31/2022
Note: Held By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM All comments below per the 2020 Florida Building Code PLAN REVIEW COMMENTS: 1. Provide all proposed elevations for review. [A]107.2.1. 2. Elevations submitted on sheet 1/9 are incorrectly noted. Revise the elevations to show the correct elevations. 3. Provide Details to how the proposed Breeze Way is to be constructed. Double 2 x 12 is called out with 4 x 4 post. Provide Footing to post connector, post to beam connector and beam to roofing connector. 4. Various call outs throughout the drawing reference #2 species. Provide the species of lumber to be used. 5. Provide a roof framing plan. 107.2.1. 6. Provide under stair protection per R302.7.
ELEC HOLD 10/26/2022 10/27/2022
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Need to show the existing size of the electrical service. 2. Need to submit electric load calcs showing the new added living space and prove the existing service can accommodate the added loads.
MECH HOLD 10/26/2022 10/28/2022
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Plans show R13 in wood frame walls. Energy Calcs say R19 and block with R5. Revise to match
PLUM COMPLETE 10/26/2022 10/31/2022
Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM
ZON HOLD 10/26/2022 10/28/2022
Note: Held By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM This project will be separated into two separate permits one for the home remodel to the existing home, and one for the proposed addition in the rear. The pool is not included in either one of these permits. This has already been taken care of with the building dept. permit numbers are as follows 2022101347 and 2022101411 Please apply for a pool permit separately. Pool needs to be labeled on site plan as future pool. Please also note it will need to be submitted on a seperate permi Site plan: missing Please show the demolition area along with the new covered porch. show material and dimensons of driveway. add A/C equiptment in the encroaching in easement on left please add a/c equipment for the rear addition and make sure to include everything in landscape plan as they should match Rename the kitchen in porch area to summer kitchen Foundation plan: Please show the demolition area along with the new covered porch area Elevation plans : 1.Height of entire home all the way to peak of new roof on the left side of the home where the bonus room is being added. 2 Rename the Elevation plans.. Left elevation should be labeled RIGHT and right elevation should be labeled LEFT. Landscape plan: will need to state there will be 9 total trees i see 8 trees drawn but only see 6 trees by name listed on the legend. Please clarify and list all nine. please make sure you add everyting that is on site plan to the landscape. Color sheet: roof is listed as shingles. Your blue prints list the new roof as metal please clarify. Also on the color sheet please list the colors of the garage
RSI CANCEL
ZON CANCEL
ENGIN1 CANCEL

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
ADJUSTMENT 50% (¤401.54) 07/14/2023
ADMINISTRATIVE RESIDENTIAL ¤30.00 07/14/2023
INSPECTION - RESIDENTIAL ¤602.25 07/14/2023
PLAN REVIEW - RESIDENTIAL ¤170.82 07/14/2023
CONTRACTOR CHANGE ¤20.00 07/14/2023
CONTRACTOR CHANGE ¤20.00 07/14/2023
RECORDING FEE REIMBURSE DOC ¤35.50 07/14/2023
SURCHARGE FS 533.721 ¤4.02 07/14/2023
SURCHARGE - FS 468.631 ¤6.02 07/14/2023
SITE PLAN 30 ¤30.00 07/14/2023
CONTRACTOR CHANGE ¤20.00
CONTRACTOR CHANGE ¤20.00
PLAN REVIEW - REVISION ¤32.50
REINSPECTION RESIDENTIAL ¤40.00
CONTRACTOR CHANGE ¤20.00
CONTRACTOR CHANGE ¤20.00
Fees Total Due: ¤152.50 Total Paid: ¤517.07