Permit #2022110056

Permit Details

Status: COED

Parcel Id: 07-11-31-7010-00140-0050
CONDITIONED SPACE: 2430 sqft
GARAGE: 699 sqft
OPENED PORCH (WITH ROOF) : 504 sqft
OPENED PORCH (WITH ROOF) : 96 sqft
Total Square Footage: 3729 sqft
Block: 00140
Subdivision: 2137 - SECTION 10-FLORIDA PARK
Job Phone: 386-627-0430
Location Address: 19 FLEMINGTON LN
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 12/02/2022
NOC: RECORDED
Applicant name: ANNA WIKTORIA LISOWSKI
Owner: HARRIS MARK & ALICE RIBEIRO HARRIS H&W

Address

43 BARN HILL LANE

NEWINGTON, CT 06111

Lot: 0050
Contracted Stated Job Value: ¤400,000.00
Job Description: SINGLE FAMILY RESIDENCE
Type: CN

Contractor

GOLDEN FOX HOME REMODELING, INC
Status Location Address State License Number Phone
ACTIVE

72 HERNANDEZ AVE

PALM COAST, FL 32137

CBC1259266 (Exp: 08/31/2026) 386-627-0430

Sub Contractors

JUAN CARLOS GONZALEZ
Status Location Address State License Number
ACTIVE

1328 COUNTY ROAD 308

CRESCENT CITY, FL 32112

RF11067806 (Exp: 08/31/2027)
THOMAS A REGULA
Status Location Address State License Number Phone Fax
INACTIVE

11320 PHILLIPS PKWY DRIVE E

JACKSONVILLE, FL 32256

CMC1250075 (Exp: 08/31/2026) 904-278-0339 904-278-0366
DANIEL J LUSINSKI
Status Location Address Mailing Address State License Number Phone
ACTIVE

389 PALM COAST PARKWAY SW

PALM COAST, FL 32137

#4

PALM COAST, FL 32137

CCC1330133 (Exp: 08/31/2026) 386-338-7926
WILLIAM TODD SIKES
Status Location Address State License Number Phone
ACTIVE

83 PORT ROYAL DR

ST AUGUSTINE, FL 32084

EC0002726 (Exp: 08/31/2026) 904-762-8762

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 10/25/2023 FINAL APPROVED AGAETANO
Note: 10/20/2023 - PREVIOUS INSPECTION NOTES Inspector Notes from Inspection 2490 03-31-2023 Duct above kitchen is crushed and foil wrapping needs to be addressed. Superintendent on site and will address ASAP. 10-20-2023 1. Master bath outlets not GFCI protected 2. Loose outlet master bedroom, rigjht side. 3. Master bath toilet window does not open. 4. Lanai ceiling vent trim not installed. 5. AHU manufacturer heat label not posted for breaker size.
ROW - FINAL APRON (AFTER POUR) 10/25/2023 APPROVED GBERTOLA
Note: CORRECTION WERE MADE AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. THIS INCLUDES BUT IS NOT LIMITED TO THE CULVERT PIPE ELEVATION FROM THE TIME OF THE INSPECTION APPROVAL TO THE CONCRETE POUR. ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 10/23/2023 - PREVIOUS INSPECTION NOTES ** 10/23/23 LEFT SIDE OF DRIVEWAY WHEN WALKING EDGE PAVERS LOOSE PAVERS MOVING UNDER FOOT PULLED OUT BY HAND NOT SECURED ______________________________________________________________________________________________________________________ 10/19/2023 - PREVIOUS INSPECTION NOTES ** 10/19/23 MULTIPLE PAVERS ALONG THE DRIVEWAYS EDGE ARE LOOSE AND PULL OUT THERE IS NO EDGE RESTRAINT TO ASSIST IN HOLDING PAVERS IN PLACE, ALL THE WAY TO EDGE OF ROAD ** MITERED ENDS ALSO HAS PAVERS THAT ARE NOT BONDED TO THE CONCRETE PAVERS ARE LOOSE AND MOVE WHEN STEPPED ON AND PULL OUT ** SEE ATTACHED PHOTOS Inspector Notes from Inspection 9465 **10/04/23 CRACK IN CONCRETE OF RIGHT SIDE DRIVEWAY FER RIGHT MITERED END 1 INCH GAP BETWEEN PAVERS AND MITERED END. ** LEFT SIDE DRIVEWAY PAVERS SET ON TOP OF MITERED ENDS EXPOSURE TO PAVER BASE UNDERNEATH ** LEFT SIDE DRIVEWAY CALLS TO 12 FEET WIDE ABOVE APRON MEASURES AT 11 FT 10 INCHES ** NEED TO REMOVE ALL PALLETS LEFT ON DRIVEWAY AS WELL AS TRAILER BEFORE FINAL ROW AND APRON INSPECTIONS
ROW - STORMWATER FINAL 10/25/2023 APPROVED GBERTOLA
Note: CORRECTION WERE MADE AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. THIS INCLUDES BUT IS NOT LIMITED TO THE CULVERT PIPE ELEVATION FROM THE TIME OF THE INSPECTION APPROVAL TO THE CONCRETE POUR. 10/23/2023 - PREVIOUS INSPECTION NOTES ** 10/23/23 ** RIGHT SIDE SOD NEEDS TO MATCH GRADE AND BE AND GRADE NEEDS TO BE 2 INCHES BELOW EDGE OF ROAD SOD IS 5 INCHES HIGH AT EDGE OF ROAD ** LEFT SIDE GRADE NEEDS TO BE 2 INCHES BELOW EDGE OF ROAD SOD SITS 5 INCHES HIGH AT EDGE OF ROAD MISSING SOD IN SWALE ON LEFT SIDE ** SEE ATTACHED PHOTOS FROM TODAYS INSPECTION ______________________________________________________________________________________________________________________ 10/19/2023 - PREVIOUS INSPECTION NOTES ** 10/19/23 MYSELF AND R. GROSS BOTH INSPECTED SITE ROAD SIDE SWALE ARE TO0 DEEP AND TOO WIDE MATERIAL WILL BE NEEDED TO MATCH EXISTING GRADES R. GROSS SPOKE WITH BUILDER ON SITE Inspector Notes from Inspection 9465 **10/04/23 CRACK IN CONCRETE OF RIGHT SIDE DRIVEWAY FER RIGHT MITERED END 1 INCH GAP BETWEEN PAVERS AND MITERED END. ** LEFT SIDE DRIVEWAY PAVERS SET ON TOP OF MITERED ENDS EXPOSURE TO PAVER BASE UNDERNEATH ** LEFT SIDE DRIVEWAY CALLS TO 12 FEET WIDE ABOVE APRON MEASURES AT 11 FT 10 INCHES ** NEED TO REMOVE ALL PALLETS LEFT ON DRIVEWAY AS WELL AS TRAILER BEFORE FINAL ROW AND APRON INSPECTIONS
ROW - FINAL APRON (AFTER POUR) 10/23/2023 Disapproved -FEE REQUIRED EMADISON
Note: ** 10/23/23 LEFT SIDE OF DRIVEWAY WHEN WALKING EDGE PAVERS LOOSE PAVERS MOVING UNDER FOOT PULLED OUT BY HAND NOT SECURED ______________________________________________________________________________________________________________________ 10/19/2023 - PREVIOUS INSPECTION NOTES ** 10/19/23 MULTIPLE PAVERS ALONG THE DRIVEWAYS EDGE ARE LOOSE AND PULL OUT THERE IS NO EDGE RESTRAINT TO ASSIST IN HOLDING PAVERS IN PLACE, ALL THE WAY TO EDGE OF ROAD ** MITERED ENDS ALSO HAS PAVERS THAT ARE NOT BONDED TO THE CONCRETE PAVERS ARE LOOSE AND MOVE WHEN STEPPED ON AND PULL OUT ** SEE ATTACHED PHOTOS Inspector Notes from Inspection 9465 **10/04/23 CRACK IN CONCRETE OF RIGHT SIDE DRIVEWAY FER RIGHT MITERED END 1 INCH GAP BETWEEN PAVERS AND MITERED END. ** LEFT SIDE DRIVEWAY PAVERS SET ON TOP OF MITERED ENDS EXPOSURE TO PAVER BASE UNDERNEATH ** LEFT SIDE DRIVEWAY CALLS TO 12 FEET WIDE ABOVE APRON MEASURES AT 11 FT 10 INCHES ** NEED TO REMOVE ALL PALLETS LEFT ON DRIVEWAY AS WELL AS TRAILER BEFORE FINAL ROW AND APRON INSPECTIONS
ROW - STORMWATER FINAL 10/23/2023 Disapproved - NO FEE EMADISON
Note: ** 10/23/23 ** RIGHT SIDE SOD NEEDS TO MATCH GRADE AND BE AND GRADE NEEDS TO BE 2 INCHES BELOW EDGE OF ROAD SOD IS 5 INCHES HIGH AT EDGE OF ROAD ** LEFT SIDE GRADE NEEDS TO BE 2 INCHES BELOW EDGE OF ROAD SOD SITS 5 INCHES HIGH AT EDGE OF ROAD MISSING SOD IN SWALE ON LEFT SIDE ** SEE ATTACHED PHOTOS FROM TODAYS INSPECTION ______________________________________________________________________________________________________________________ 10/19/2023 - PREVIOUS INSPECTION NOTES ** 10/19/23 MYSELF AND R. GROSS BOTH INSPECTED SITE ROAD SIDE SWALE ARE TO0 DEEP AND TOO WIDE MATERIAL WILL BE NEEDED TO MATCH EXISTING GRADES R. GROSS SPOKE WITH BUILDER ON SITE Inspector Notes from Inspection 9465 **10/04/23 CRACK IN CONCRETE OF RIGHT SIDE DRIVEWAY FER RIGHT MITERED END 1 INCH GAP BETWEEN PAVERS AND MITERED END. ** LEFT SIDE DRIVEWAY PAVERS SET ON TOP OF MITERED ENDS EXPOSURE TO PAVER BASE UNDERNEATH ** LEFT SIDE DRIVEWAY CALLS TO 12 FEET WIDE ABOVE APRON MEASURES AT 11 FT 10 INCHES ** NEED TO REMOVE ALL PALLETS LEFT ON DRIVEWAY AS WELL AS TRAILER BEFORE FINAL ROW AND APRON INSPECTIONS
BLD - BUILDING FINAL 10/20/2023 Disapproved - NO FEE AGAETANO
Note: Inspector Notes from Inspection 2490 03-31-2023 Duct above kitchen is crushed and foil wrapping needs to be addressed. Superintendent on site and will address ASAP. 10-20-2023 1. Master bath outlets not GFCI protected 2. Loose outlet master bedroom, rigjht side. 3. Master bath toilet window does not open. 4. Lanai ceiling vent trim not installed. 5. AHU manufacturer heat label not posted for breaker size.
ROW - FINAL APRON (AFTER POUR) 10/19/2023 Disapproved -FEE REQUIRED EMADISON
Note: ** 10/19/23 MULTIPLE PAVERS ALONG THE DRIVEWAYS EDGE ARE LOOSE AND PULL OUT THERE IS NO EDGE RESTRAINT TO ASSIST IN HOLDING PAVERS IN PLACE, ALL THE WAY TO EDGE OF ROAD ** MITERED ENDS ALSO HAS PAVERS THAT ARE NOT BONDED TO THE CONCRETE PAVERS ARE LOOSE AND MOVE WHEN STEPPED ON AND PULL OUT ** SEE ATTACHED PHOTOS _____________________________________________________________________________________________________________________ Inspector Notes from Inspection 9465 **10/04/23 CRACK IN CONCRETE OF RIGHT SIDE DRIVEWAY FER RIGHT MITERED END 1 INCH GAP BETWEEN PAVERS AND MITERED END. ** LEFT SIDE DRIVEWAY PAVERS SET ON TOP OF MITERED ENDS EXPOSURE TO PAVER BASE UNDERNEATH ** LEFT SIDE DRIVEWAY CALLS TO 12 FEET WIDE ABOVE APRON MEASURES AT 11 FT 10 INCHES ** NEED TO REMOVE ALL PALLETS LEFT ON DRIVEWAY AS WELL AS TRAILER BEFORE FINAL ROW AND APRON INSPECTIONS
ROW - STORMWATER FINAL 10/19/2023 Disapproved -FEE REQUIRED EMADISON
Note: ** 10/19/23 MYSELF AND R. GROSS BOTH INSPECTED SITE ROAD SIDE SWALE ARE TO0 DEEP AND TOO WIDE MATERIAL WILL BE NEEDED TO MATCH EXISTING GRADES R. GROSS SPOKE WITH BUILDER ON SITE Inspector Notes from Inspection 9465 **10/04/23 CRACK IN CONCRETE OF RIGHT SIDE DRIVEWAY FER RIGHT MITERED END 1 INCH GAP BETWEEN PAVERS AND MITERED END. ** LEFT SIDE DRIVEWAY PAVERS SET ON TOP OF MITERED ENDS EXPOSURE TO PAVER BASE UNDERNEATH ** LEFT SIDE DRIVEWAY CALLS TO 12 FEET WIDE ABOVE APRON MEASURES AT 11 FT 10 INCHES ** NEED TO REMOVE ALL PALLETS LEFT ON DRIVEWAY AS WELL AS TRAILER BEFORE FINAL ROW AND APRON INSPECTIONS
U -UTILITY RESIDENTIAL FINAL 10/18/2023 FINAL APPROVED DHANEY
U-CROSS CONNECTION 10/18/2023 APPROVED DHANEY
ROW- FINAL SURVEY/GRADING CERTIFICATION 10/04/2023 APPROVED EMADISON
ROW FIELD SURVEY /GRADING CERTIFICATION 10/04/2023 APPROVED - AS NOTED EMADISON
Note: **10/04/23 CRACK IN CONCRETE OF RIGHT SIDE DRIVEWAY FER RIGHT MITERED END 1 INCH GAP BETWEEN PAVERS AND MITERED END. ** LEFT SIDE DRIVEWAY PAVERS SET ON TOP OF MITERED ENDS EXPOSURE TO PAVER BASE UNDERNEATH ** LEFT SIDE DRIVEWAY CALLS TO 12 FEET WIDE ABOVE APRON MEASURES AT 11 FT 10 INCHES ** NEED TO REMOVE ALL PALLETS LEFT ON DRIVEWAY AS WELL AS TRAILER BEFORE FINAL ROW AND APRON INSPECTIONS
U - SEWER TIE IN 08/09/2023 APPROVED - AS NOTED MGIBSON
Note: THIS WAS A VIRTUAL INSPECTION
GRAVITY SEWER TEST 08/09/2023 APPROVED - AS NOTED MGIBSON
Note: THIS WAS A VIRTUAL INSPECTION
ROW- PRE-APRON (PRE-POUR) 08/07/2023 APPROVED GBERTOLA
Note: 8/7/23= ready for PAVERS ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 8/3/2023 - PREVIOUS INSPECTION NOTES IT'S YOUR RESPONSIBILITY TO CHECK THE CULVERT ELEVATION BEFORE POURING CONCRETE FOR THE DRIVEWAY. ALL CONCRETE NEEDS TO BE 3000PSI WITH FIBER OR WITH METAL MESH TO MEET ALL CITY'S STANDARTS. BEFORE THE NEXT PRE POUR ALL PAVER BASE NEEDS TO BE SPREAD AND COMPACTED WITH NO PAVERS At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved. ------------------------------------------------------------------------------------------------------------- 7/21/23= builder ask me to stop by again and check the site, AS A COURTESY INSPECTOR WENT BACK AND RE INSPECTED. WING IN THE APRON WASN'T FORM. TOO SOFT AROUND THE CULVERT PIPE. PIPE ON THE LEFT DRIVEWAY WAS OUT OF TOLERANCE, NO PAVERS RESTRAINT.
ROW- PRE-APRON (PRE-POUR) 08/03/2023 PARTIALLY APPROVED PFLANAGAN
Note: IT'S YOUR RESPONSIBILITY TO CHECK THE CULVERT ELEVATION BEFORE POURING CONCRETE FOR THE DRIVEWAY. ALL CONCRETE NEEDS TO BE 3000PSI WITH FIBER OR WITH METAL MESH TO MEET ALL CITY'S STANDARTS. BEFORE THE NEXT PRE POUR ALL PAVER BASE NEEDS TO BE SPREAD AND COMPACTED WITH NO PAVERS At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved. ------------------------------------------------------------------------------------------------------------- 7/21/23= builder ask me to stop by again and check the site, AS A COURTESY INSPECTOR WENT BACK AND RE INSPECTED. WING IN THE APRON WASN'T FORM. TOO SOFT AROUND THE CULVERT PIPE. PIPE ON THE LEFT DRIVEWAY WAS OUT OF TOLERANCE, NO PAVERS RESTRAINT.
ROW- PRE-APRON (PRE-POUR) 07/24/2023 CANCELLED BY APPLICANT WEB
Note: 7/21/2023 - PREVIOUS INSPECTION NOTES ** 07/21/23 SITE NOT READY FOR INSPECTION ** PHOTOS WILL BE ATTACHED
ROW- PROJECT STATUS 07/21/2023 APPROVED - AS NOTED GBERTOLA
Note: 7/21/23= builder ask me to stop by again and check the site, AS A COURTESY INSPECTOR WENT BACK AND RE INSPECTED. WING IN THE APRON WASN'T FORM. TOO SOFT AROUND THE CULVERT PIPE. PIPE ON THE LEFT DRIVEWAY WAS OUT OF TOLERANCE, NO PAVERS RESTRAINT.
ROW- PRE-APRON (PRE-POUR) 07/21/2023 Disapproved - NO FEE EMADISON
Note: ** 07/21/23 SITE NOT READY FOR INSPECTION ** PHOTOS WILL BE ATTACHED
ROW - DRAINAGE 06/21/2023 APPROVED EMADISON
Note: 6/16/2023 - PREVIOUS INSPECTION NOTES ** 06/16/23 BUILDER NEEDS TO OPEN UP THE ROAD SIDE SWALE EITHER INSTALL A TEM[ORARY CULVERT OR OPEN AND MAINTAIN SWALE ON A DAILY BASIS SPOKE WITH BUILDER ON SITE ** REMOVE PORT-A-JOHN FROM ROAD SIDE SWALE PLACE ONTO JOB SITE ** YOUR SITE S DRAINAGE IS HAVING A NEGATIVE IMPACT ON ADJACENT PROPERTIES AND THE ROADWAY AS WATER IS BACKING UP INTO ROAD WHICH IS A SAFETY HAZARD ** SEE ATTACHED PHOTOS ** FOLLOW UP INSPECTION ON 06/21/23
ROW - DRAINAGE 06/16/2023 Disapproved - NO FEE EMADISON
Note: ** 06/16/23 BUILDER NEEDS TO OPEN UP THE ROAD SIDE SWALE EITHER INSTALL A TEM[ORARY CULVERT OR OPEN AND MAINTAIN SWALE ON A DAILY BASIS SPOKE WITH BUILDER ON SITE ** REMOVE PORT-A-JOHN FROM ROAD SIDE SWALE PLACE ONTO JOB SITE ** YOUR SITE S DRAINAGE IS HAVING A NEGATIVE IMPACT ON ADJACENT PROPERTIES AND THE ROADWAY AS WATER IS BACKING UP INTO ROAD WHICH IS A SAFETY HAZARD ** SEE ATTACHED PHOTOS ** FOLLOW UP INSPECTION ON 06/21/23
ELECTRIC - EARLY POWER 05/31/2023 APPROVED - AS NOTED BTAYLOR
Note: 5-31-23 1. Emailed FPL at 9:52.
INSULATION 03/31/2023 APPROVED - AS NOTED AGAETANO
Note: 03-31-2023 Duct above kitchen is crushed and foil wrapping needs to be addressed. Superintendent on site and will address ASAP.
ELECTRIC - EARLY POWER 03/28/2023 CANCELLED BY APPLICANT WEB
LATH/BRICK/ WATER BARRIER 03/16/2023 APPROVED FWILLIS
ALL ROUGH 03/14/2023 APPROVED AGAETANO
Note: 3/13/2023 - PREVIOUS INSPECTION NOTES 3/10/2023 - PREVIOUS INSPECTION NOTES Inspector Notes from Inspection 2450 Inspector Notes from Inspection 2460 02-11-2023 Sheet 3 Interior wall bracing not installed as per plans. See highlighted area on drawings. Check at next inspection. 03-01-2023 Job site is a mess. Please remove the trrash from the site prior to next inspection. Debris has blown over to the empty lot, the site, and dumpster is empty. 03-10-2023 1. Energy calcs not on site. 2. Dryer vent not sealed completely at roof deck. 3. Address not visible from street. Job box is behind CMU and Job Johnny. R319.1 Address identification. Buildings shall be provided with approved address identification. The address identification shall be legible and placed in a position that is visiblen from the street or road fronting the property. Address identification characters shall contrast with their background. Address numbers shall be Arabic numbers or alphabetical letters. Numbers shall not be spelled out. Each character shall be not less than 4 inches (102 mm) in height with a stroke width of not less than 0.5 inch (12.7 mm). Where required by the fire code official, address identification shall be provided in additional approved locations to facilitate emergency response. Where access is by means of a private road and the building address cannot be viewed from the public way, a monument, pole or other sign or means shall be used to identify the structure. Address identification shall be maintained. Inspection stopped. 03-11-2023 1. U Factor and SHGC calcs and window stickers do not match. Please revision and submit to the building department. 2. Framing not complete. 3. Note to contractor. Entry and living area has puddles on the slab.
ALL ROUGH 03/13/2023 Disapproved -FEE REQUIRED AGAETANO
Note: 3/10/2023 - PREVIOUS INSPECTION NOTES Inspector Notes from Inspection 2450 Inspector Notes from Inspection 2460 02-11-2023 Sheet 3 Interior wall bracing not installed as per plans. See highlighted area on drawings. Check at next inspection. 03-01-2023 Job site is a mess. Please remove the trrash from the site prior to next inspection. Debris has blown over to the empty lot, the site, and dumpster is empty. 03-10-2023 1. Energy calcs not on site. 2. Dryer vent not sealed completely at roof deck. 3. Address not visible from street. Job box is behind CMU and Job Johnny. R319.1 Address identification. Buildings shall be provided with approved address identification. The address identification shall be legible and placed in a position that is visiblen from the street or road fronting the property. Address identification characters shall contrast with their background. Address numbers shall be Arabic numbers or alphabetical letters. Numbers shall not be spelled out. Each character shall be not less than 4 inches (102 mm) in height with a stroke width of not less than 0.5 inch (12.7 mm). Where required by the fire code official, address identification shall be provided in additional approved locations to facilitate emergency response. Where access is by means of a private road and the building address cannot be viewed from the public way, a monument, pole or other sign or means shall be used to identify the structure. Address identification shall be maintained. Inspection stopped. 03-11-2023 1. U Factor and SHGC calcs and window stickers do not match. Please revision and submit to the building department. Please have on site. 2. Framing not complete. 3. Note to contractor. Entry and living area has puddles on the slab. 4. Piggy back plates not installed.
ELECTRIC-TUG 03/13/2023 APPROVED AGAETANO
ALL ROUGH 03/10/2023 Disapproved - NO FEE AGAETANO
Note: Inspector Notes from Inspection 2450 Inspector Notes from Inspection 2460 02-11-2023 Sheet 3 Interior wall bracing not installed as per plans. See highlighted area on drawings. Check at next inspection. 03-01-2023 Job site is a mess. Please remove the trrash from the site prior to next inspection. Debris has blown over to the empty lot, the site, and dumpster is empty. 03-10-2023 1. Energy calcs not on site. 2. Dryer vent not sealed completely at roof deck. 3. Address not visible from street. Job box is behind CMU and Job Johnny. R319.1 Address identification. Buildings shall be provided with approved address identification. The address identification shall be legible and placed in a position that is visiblen from the street or road fronting the property. Address identification characters shall contrast with their background. Address numbers shall be Arabic numbers or alphabetical letters. Numbers shall not be spelled out. Each character shall be not less than 4 inches (102 mm) in height with a stroke width of not less than 0.5 inch (12.7 mm). Where required by the fire code official, address identification shall be provided in additional approved locations to facilitate emergency response. Where access is by means of a private road and the building address cannot be viewed from the public way, a monument, pole or other sign or means shall be used to identify the structure. Address identification shall be maintained. Inspection stopped.
WALL SHEATHING 03/01/2023 APPROVED - AS NOTED AGAETANO
Note: Inspector Notes from Inspection 2460 02-11-2023 Sheet 3 Interior wall bracing not installed as per plans. See highlighted area on drawings. Check at next inspection. 03-01-2023 Job site is a mess. Please remove the trrash from the site prior to next inspection. Debris has blown over to the empty lot, the site, and dumpster is empty.
ROOF VALLEY & METAL 03/01/2023 APPROVED - AS NOTED AGAETANO
Note: Inspector Notes from Inspection 2460 02-11-2023 Sheet 3 Interior wall bracing not installed as per plans. See highlighted area on drawings. Check at next inspection. 03-01-2023 Job site is a mess. Please remove the trrash from the site prior to next inspection. Debris has blown over to the empty lot, the site, and dumpster is empty.
ROOF SHEATHING / BRACES/TIES/DOWN CELL 02/21/2023 APPROVED - AS NOTED AGAETANO
Note: 02-11-2023 Sheet 3 Interior wall bracing not installed as per plans. See highlighted area on drawings. Check at next inspection.
TIE BEAM / LINTEL 01/31/2023 APPROVED AGAETANO
FOUND SURVEY APPROVED (OFFICE) 01/19/2023 APPROVED TBAKER
MONOLITHIC SLAB 01/11/2023 APPROVED AGAETANO
PLUMBING 1ST ROUGH UNDERGROUND 01/09/2023 APPROVED MGIBSON
WATER METER INSTALLATION REQUEST 01/06/2023 APPROVED CSTONE

Review History

Department Status Date In Date Out
MECH COMPLETE 10/19/2023 10/19/2023
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
SW1 COMPLETE 10/19/2023 10/25/2023
Note: Released By: GABRIEL BERTOLA - (386)986-7660 - GBERTOLA@PALMCOASTGOV.COM
ZON COMPLETE 10/19/2023 10/19/2023
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
MECH COMPLETE 03/13/2023 03/13/2023
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
ENGIN1 COMPLETE 01/18/2023 01/19/2023
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON COMPLETE 01/18/2023 01/18/2023
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
BADMIN INFORMATION 01/03/2023 01/03/2023
Note: Marked INFORMATION By: MICHELLE RAMOS - - MRAMOS@PALMCOASTGOV.COM NOC line 9 states expiration date December 27, 2022. Need to submit new NOC.
ZON HOLD 12/02/2022 12/02/2022
Note: Held By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM please submit originals to our office
ZON COMPLETE 12/02/2022 12/02/2022
Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM
ZON HOLD 11/23/2022 11/09/2022
Note: Held By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM The right of way form you submitted is for a Trust is this property in a trust? I dont see that in our records. I will send a reg ROW form to your email. please make sure to add the ac unit exactly how ut a[ppears on the site plan and floor plan
ZON HOLD 11/23/2022 11/23/2022
Note: Held By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM Repeat comment: The right of way form you submitted is for a Trust is this property in a trust? I dont see that in our records. I will send a reg ROW form to your email. Please send in the Row agreement
SW1 COMPLETE 11/23/2022 12/02/2022
Note: Released By: ROBERT GROSS - (386)986-4769 - RGROSS@PALMCOASTGOV.COM
ZON HOLD 11/09/2022 11/09/2022
Note: Held By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM Landscape plan does nnot match floor plan and site plan. The location of the mechanical equiptment shows further back than landscape plan
ELEC COMPLETE 11/09/2022 11/09/2022
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
SW1 HOLD 11/09/2022 11/21/2022
Note: Held By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM NEED TO SUBMIT A NEW SITE PLAN THAT IS NOT REJECTED IN THE SYSTEM
BLD COMPLETE 11/01/2022 11/04/2022
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
CUSVC COMPLETE 11/01/2022 11/09/2022
Note: Released By: CYNTHIA SCHWEERS - - CSCHWEERS@PALMCOASSTGOV.COM
ELEC HOLD 11/01/2022 11/02/2022
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Need correct outlet spacing in master bedroom. NEC 2017 210.52 2. Need light and switch by exterior garage door. NEC 2017 210.70
ENGIN1 COMPLETE 11/01/2022 11/01/2022
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
LOCATE COMPLETE 11/01/2022 11/04/2022
Note: Released By: CANDACE STONE - - CSTONE@PALMCOASTGOV.COM
MECH COMPLETE 11/01/2022 11/02/2022
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
SW1 HOLD 11/01/2022 11/04/2022
Note: Held By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM NEED TO SUBMIT A NEW SITE PLAN THAT IS NOT REJECTED
SWALE COMPLETE 11/01/2022 03/06/2023
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
PLAN REVIEW - REVISION ¤32.50 10/25/2023
PLAN REVIEW - REVISION ¤32.50 10/25/2023
REINSPECTION RESIDENTIAL ¤40.00 10/25/2023
SW ENG - INSPECTION 20 ¤20.00 10/25/2023
SW ENG - INSPECTION 20 ¤20.00 10/25/2023
SW ENG REINSPECTION 20 ¤20.00 10/25/2023
SW ENG REINSPECTION 20 ¤20.00 10/25/2023
SW ENG REINSPECTION 20 ¤20.00 10/25/2023
SW ENG REINSPECTION 20 ¤20.00 10/25/2023
SW ENG - REVIEW 20 ¤20.00 12/02/2022
SW ENG RES REVIEW 200 ¤200.00 12/02/2022
TRANS IMPACT FEE ADMIN ¤52.92 12/02/2022
TRANS IMPACT FEE ADMIN (¤52.92) 12/02/2022
SEWER CREDIT (¤35.48) 12/02/2022
SEWER INSPECTION ¤25.00 12/02/2022
SEWER CAPITAL FACILITY ¤4,939.76 12/02/2022
WATER CAPITAL FACILITY FEE ¤3,626.50 12/02/2022
SITE PLAN 30 ¤30.00 12/02/2022
SW ENG INSPECTION 80 ¤80.00 12/02/2022
SW ENG PRE APRON ¤30.00 12/02/2022
WATER- TURN ON ¤25.00 12/02/2022
ADJUSTMENT 50% (¤721.00) 12/02/2022
ADMINISTRATIVE RESIDENTIAL ¤30.00 12/02/2022
INSPECTION - RESIDENTIAL ¤1,100.00 12/02/2022
PLAN REVIEW - RESIDENTIAL ¤312.00 12/02/2022
CONNECTION FEES ¤1,077.88 12/02/2022
FIRE IMPACT FEE ADMIN ¤12.62 12/02/2022
FIRE IMPACT FEE ADMIN (¤12.62) 12/02/2022
IMPACT FEE FIRE ¤420.52 12/02/2022
IMPACT FEE PARKS ¤1,769.15 12/02/2022
IMPACT FEE SCHOOL ¤5,450.00 12/02/2022
RECORDING FEE REIMBURSE DOC ¤44.00 12/02/2022
IMPACT FEE TRANSPORTATION ¤1,764.00 12/02/2022
WATER -IRRIGATION INSPECTION ¤25.00 12/02/2022
PARKS IMPACT FEE ADMIN ¤53.07 12/02/2022
PARKS IMPACT FEE ADMIN (¤53.07) 12/02/2022
SURCHARGE FS 533.721 ¤4.50 12/02/2022
SURCHARGE - FS 468.631 ¤6.75 12/02/2022
SW ENG - FOUNDATION SURVEY ¤20.00 12/02/2022
Fees Total Due: ¤0.00 Total Paid: ¤20,468.58