Permit #2022110119

Permit Details

Status: FINAL

Parcel Id: 42-10-30-3210-00000-1940
Total Square Footage: 1162 sqft
Block: 00000
Subdivision: 2094 - CONSERVATORY AT HAMMOCK BEACH
Job Phone: 386-679-5224
Location Address: 451 SWEETGUM LN
Type: PO - POOL
Issue Date: 01/30/2023
NOC: RECORDED
Applicant name: DONALD SHON MYRICK
Owner: ENGLESON JOSEPH & BARBARA H&W

Address

1112 S PACIFIC STREET

OCEANSIDE, CA 92054

Lot: 1940
Contracted Stated Job Value: ¤65,000.00
Job Description: POOL
Type: CN

Contractor

MYRICK POOLS
Status Location Address State License Number Phone
ACTIVE

1457 N US 1

ORMOND BEACH, FL 32174

CPC052531 (Exp: 08/31/2026) 386-334-9822

Sub Contractors

STEPHEN COURTEAUX
Status Location Address State License Number Phone Fax
ACTIVE

85 North Yonge Street

Ormond Beach, FL 32174

EC13001748 (Exp: 08/31/2026) (386) 672-4900 386-676-7472
DONALD SHON MYRICK
Status Location Address State License Number Phone
ACTIVE

1457 N US 1

ORMOND BEACH, FL 32174

CPC052531 (Exp: 08/31/2026) 386-334-9822

Inspection History

Type Request Date Result Inspector
POOL FINAL 01/23/2024 FINAL APPROVED AGAETANO
U -UTILITY RESIDENTIAL FINAL 01/03/2024 FINAL APPROVED JHARDING
ROW- FINAL SURVEY/GRADING CERTIFICATION 08/29/2023 APPROVED EMADISON
ROW FIELD SURVEY /GRADING CERTIFICATION 08/29/2023 APPROVED EMADISON
ROW - FINAL INSPECTION 08/29/2023 FINAL APPROVED EMADISON
ELECTRIC AND ALARM 08/23/2023 APPROVED - AS NOTED AGAETANO
Note: 08-23-2023 Screen enclosure steps not per code. Retaining wall at back of pool will not per code concernng guards. GUARDS AND WINDOW FALL PROTECTION R312.1 Guards. Guards shall be provided in accordance with Sections R312.1.1 through R312.1.4. R312.1.1 Where required. Guards shall be provided for those portions of open-sided walking surfaces, including stairs, ramps and landings, that are located more than 30 inches (762 mm) measured vertically to the floor or grade below at any point within 36 inches (914 mm) horizontally to the edge of the open side. Insect screening shall not be considered as a guard. R312.1.2 Height. Required guards at open-sided walking surfaces, including stairs, porches, balconies or landings, shall be not less than 36 inches (914 mm) in height as measured vertically above the adjacent walking surface or the line connecting the nosings. Check at final.
POOL DECK 07/27/2023 APPROVED AGAETANO
Note: 6/15/2023 - PREVIOUS INSPECTION NOTES Inspector Notes from Inspection 2270 6/5/2023 - PREVIOUS INSPECTION NOTES 06-01-2023 1. Contractor requested incorrect inspection. Retaining wall foundation and or retaining wall foundation needed. 2. Sheet 4 of 4 indicates one pour and #3 horizontal bars every 12". Bars not installed. Please provide engineering if this is to be a CMU wall. Please provide clarification on horizontal bars to be installed. These bars will need to be inspected when installed. 3. Plumbing pipe needs to be sleeved or provide engineering that plumbing pipe can be installed as such. 06-05-2023 Plumbing line not relocated. Step down footing revision not submitted to the building department. Please submit revision prior to pool deck inspection. Inspector spoke with Darlene on 06-02-2023. Bottom of step down footing is approximately 52" and footing is approximately 40". 06-07-2023 Please remove soil from bottom of footing prior to concrete pour. 06-15-2023 - Not ready for inspection.
POOL DECK 06/15/2023 Disapproved - NO FEE AGAETANO
Note: Inspector Notes from Inspection 2270 6/5/2023 - PREVIOUS INSPECTION NOTES 06-01-2023 1. Contractor requested incorrect inspection. Retaining wall foundation and or retaining wall foundation needed. 2. Sheet 4 of 4 indicates one pour and #3 horizontal bars every 12". Bars not installed. Please provide engineering if this is to be a CMU wall. Please provide clarification on horizontal bars to be installed. These bars will need to be inspected when installed. 3. Plumbing pipe needs to be sleeved or provide engineering that plumbing pipe can be installed as such. 06-05-2023 Plumbing line not relocated. Step down footing revision not submitted to the building department. Please submit revision prior to pool deck inspection. Inspector spoke with Darlene on 06-02-2023. Bottom of step down footing is approximately 52" and footing is approximately 40". 06-07-2023 Please remove soil from bottom of footing prior to concrete pour. 06-15-2023 - Not ready for inspection.
STEM WALL FOUNDATION 06/15/2023 APPROVED AGAETANO
Note: Inspector Notes from Inspection 2270 6/5/2023 - PREVIOUS INSPECTION NOTES 06-01-2023 1. Contractor requested incorrect inspection. Retaining wall foundation and or retaining wall foundation needed. 2. Sheet 4 of 4 indicates one pour and #3 horizontal bars every 12". Bars not installed. Please provide engineering if this is to be a CMU wall. Please provide clarification on horizontal bars to be installed. These bars will need to be inspected when installed. 3. Plumbing pipe needs to be sleeved or provide engineering that plumbing pipe can be installed as such. 06-05-2023 Plumbing line not relocated. Step down footing revision not submitted to the building department. Please submit revision prior to pool deck inspection. Inspector spoke with Darlene on 06-02-2023. Bottom of step down footing is approximately 52" and footing is approximately 40". 06-07-2023 Please remove soil from bottom of footing prior to concrete pour.
FOOTER 06/07/2023 APPROVED - AS NOTED AGAETANO
Note: 6/5/2023 - PREVIOUS INSPECTION NOTES 06-01-2023 1. Contractor requested incorrect inspection. Retaining wall foundation and or retaining wall foundation needed. 2. Sheet 4 of 4 indicates one pour and #3 horizontal bars every 12". Bars not installed. Please provide engineering if this is to be a CMU wall. Please provide clarification on horizontal bars to be installed. These bars will need to be inspected when installed. 3. Plumbing pipe needs to be sleeved or provide engineering that plumbing pipe can be installed as such. 06-05-2023 Plumbing line not relocated. Step down footing revision not submitted to the building department. Please submit revision prior to pool deck inspection. Inspector spoke with Darlene on 06-02-2023. Bottom of step down footing is approximately 52" and footing is approximately 40". 06-07-2023 Please remove soil from bottom of footing prior to concrete pour.
FOOTER 06/06/2023 CANCELLED BY APPLICANT WEB
FOOTER 06/05/2023 Disapproved -FEE REQUIRED AGAETANO
Note: 06-01-2023 1. Contractor requested incorrect inspection. Retaining wall foundation and or retaining wall foundation needed. 2. Sheet 4 of 4 indicates one pour and #3 horizontal bars every 12". Bars not installed. Please provide engineering if this is to be a CMU wall. Please provide clarification on horizontal bars to be installed. These bars will need to be inspected when installed. 3. Plumbing pipe needs to be sleeved or provide engineering that plumbing pipe can be installed as such. 06-05-2023 Plumbing line not relocated. Step down footing revision not submitted to the building department. Please submit revision prior to pool deck inspection. Inspector spoke with Darlene on 06-02-2023. Bottom of step down footing is approximately 52" and footing is approximately 40".
STEM WALL FOUNDATION 06/02/2023 CANCELLED BY APPLICANT WEB
FOOTER 06/02/2023 CANCELLED BY APPLICANT WEB
POOL DECK 06/01/2023 Disapproved - NO FEE AGAETANO
Note: 5/24/2023 - PREVIOUS INSPECTION NOTES 05-24-2023 Terminte bond not posted. Contractor not ready. 06-01-2023 1. Contractor requested incorrect inspection. Retaining wall foundation and or retaining wall foundation needed. 1. Sheet 4 of 4 indicates one pour and #3 horizontal bars every 12". Bars not installed. Please provide engineering if this is to be a CMU wall. Please provide clarification on horizontal bars to be installed. These bars will need to be inspected when installed. 2. Plumbing pipe needs to be sleeved or provide engineering that plumbing pipe can be installed as such.
POOL DECK 05/24/2023 Disapproved -FEE REQUIRED AGAETANO
Note: 05-24-2023 Terminte bond not posted. Contractor not ready. Stem wall not complete. Soil has collapsed into the footing area. Footing inspection and stem wall inspection will need to be added.
STEEL AND GROUND 03/20/2023 APPROVED AGAETANO

Review History

Department Status Date In Date Out
BLD COMPLETE 01/30/2023 01/30/2023
Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM
ZON COMPLETE 01/30/2023 01/30/2023
Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM
SW1 COMPLETE 11/21/2022 11/30/2022
Note: Released By: GABRIEL BERTOLA - (386)986-7660 - GBERTOLA@PALMCOASTGOV.COM
BLD COMPLETE 11/02/2022 11/04/2022
Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM
ELEC COMPLETE 11/02/2022 11/02/2022
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
MECH COMPLETE 11/02/2022 11/03/2022
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
SW1 HOLD 11/02/2022 11/07/2022
Note: Held By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM NEED TO SHOW DRAINAGE OF THE LOT AFTER TE POOL IS BUILT BY HAVING FLOW ARROWS
ZON COMPLETE 11/02/2022 11/03/2022
Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION RESIDENTIAL ¤40.00 06/06/2023
REINSPECTION RESIDENTIAL ¤40.00 06/06/2023
PLAN REVIEW - REVISION ¤32.50 03/03/2023
SURCHARGE FS 533.721 ¤2.00 01/30/2023
SURCHARGE - FS 468.631 ¤2.00 01/30/2023
SW ENG INSPECTION 40 ¤40.00 01/30/2023
SW ENG - REVIEW 20 ¤20.00 01/30/2023
SITE PLAN 30 ¤30.00 01/30/2023
ADJUSTMENT 50% (¤127.50) 01/30/2023
ADMINISTRATIVE RESIDENTIAL ¤30.00 01/30/2023
INSPECTION- POOL ¤160.00 01/30/2023
PLAN REVIEW - RESIDENTIAL ¤65.00 01/30/2023
Fees Total Due: ¤0.00 Total Paid: ¤334.00