I want to search for...
Permit #2022110387
Permit Details
Status: FINAL
| Parcel Id: 07-11-31-7032-00340-0210 |
| Block: 00340 |
| Subdivision: 2155 - SECTION 32-ROYAL PALMS |
| Job Phone: 904-610-4499 |
| Location Address: 89 ROLLING SANDS DR |
| Type: GEN - GENERATOR |
| Issue Date: 11/15/2022 |
| NOC: RECORDED |
| Applicant name: ANTHONY MODESTO SCHREIBER |
| Owner: ATWELL CHERYL & & KENNETH N |
|
Address 89 ROLLINS SANDS DR PALM COAST, FL 32164 |
| Lot: 0210 |
| Contracted Stated Job Value: ¤17,550.00 |
| Job Description: INSTALLATION ON 22KW WITH ATS AND 2 120 GAL ABOVE GROUND PROPANE TANKS |
| Type: CN |
Contractor
AA SERVICE AND REPAIR NORTH FLORIDA AC
| Status | Location Address | State License Number | Phone | Fax |
| INACTIVE |
PO BOX 57896 JACKSONVILLE, FL 32258 |
CMC1249701 (Exp: 08/31/2026) | 904-610-4499 | 904-288-8164 |
Sub Contractors
ANTHONY MODESTO SCHREIBER
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
PO BOX 57896 JACKSONVILLE, FL 32258 |
CFC1427665 (Exp: 08/31/2026) | 904-626-8199 | 904-288-8164 |
Inspection History
| Type | Request Date | Result | Inspector |
| ELECTRIC FINAL | 07/07/2023 | FINAL APPROVED | JWALKER |
| Note: 6/16/2023 - PREVIOUS INSPECTION NOTES 6/16/23 Start up passed. Revision submitted has been accepted, Revision need to be approved by the building department before the inspeection can be passed. 5/30/2023 - PREVIOUS INSPECTION NOTES revision requested prior needs to be approved and on site for inspection 12/2/2022 - PREVIOUS INSPECTION NOTES Electrical rise is showing a 200 amp service. Existing panel is 150 amp . Please submitt a revision to the building department showing the correct wire size , breaker size. | |||
| ELECTRIC FINAL | 06/16/2023 | Disapproved - NO FEE | JWALKER |
| Note: 6/16/23 Start up passed. Revision submitted has been accepted, Revision need to be approved by the building department before the inspeection can be passed. 5/30/2023 - PREVIOUS INSPECTION NOTES revision requested prior needs to be approved and on site for inspection 12/2/2022 - PREVIOUS INSPECTION NOTES Electrical rise is showing a 200 amp service. Existing panel is 150 amp . Please submitt a revision to the building department showing the correct wire size , breaker size. | |||
| GAS FINAL | 05/30/2023 | APPROVED | MGIBSON |
| Note: 12/2/2022 - PREVIOUS INSPECTION NOTES | |||
| ELECTRIC FINAL | 05/30/2023 | Disapproved - NO FEE | LMILLER |
| Note: revision requested prior needs to be approved and on site for inspection 12/2/2022 - PREVIOUS INSPECTION NOTES Electrical rise is showing a 200 amp service. Existing panel is 150 amp . Please submitt a revision to the building department showing the correct wire size , breaker size. | |||
| ELECTRIC FINAL | 12/02/2022 | Disapproved - NO FEE | JWALKER |
| Note: Electrical rise is showing a 200 amp service. Existing panel is 150 amp . Please submitt a revision to the building department showing the correct wire size , breaker size. | |||
| GAS FINAL | 12/02/2022 | CANCELLED BY APPLICANT | MGIBSON |
| GAS ROUGH | 11/29/2022 | APPROVED | MGIBSON |
Review History
| Department | Status | Date In | Date Out |
| ELEC | COMPLETE | 06/15/2023 | 06/20/2023 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| BADMIN | INFORMATION | 11/15/2022 | 11/15/2022 |
| Note: Marked INFORMATION By: LIBBY MUSGROVE - - LMUSGROVE@PALMCOASTGOV.COM application is not completed correctly - only sign in contractor area, needs value and description | |||
| PLUM | COMPLETE | 11/09/2022 | 11/09/2022 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 11/09/2022 | 11/09/2022 |
| Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM | |||
| ELEC | COMPLETE | 11/08/2022 | 11/08/2022 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ZON | HOLD | 11/08/2022 | 11/08/2022 |
| Note: Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM Please provide the full copy of the survey/site plan with generator and tanks location so we can review that this is the survey for the correct property | |||
| PLUM | HOLD | 11/08/2022 | 11/08/2022 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Provide gas piping material ,size and length from tanks to second stage regulator on gas riser diagram |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| ADJUSTMENT 50% | (¤61.25) | 11/15/2022 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 11/15/2022 |
| INSPECTION - RESIDENTIAL | ¤60.00 | 11/15/2022 |
| PLAN REVIEW - MISC 32.50 | ¤32.50 | 11/15/2022 |
| SURCHARGE FS 533.721 | ¤2.00 | 11/15/2022 |
| SURCHARGE - FS 468.631 | ¤2.00 | 11/15/2022 |
| SITE PLAN 15 | ¤15.00 | 11/15/2022 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤80.25 |