I want to search for...

Permit #2022110720

Permit Details

Status: COED

Parcel Id: 07-11-31-7081-00150-0030
Total Square Footage: 31 sqft
Block: 00150
Subdivision: 2183 - SECTION 81-BERNARD MEADOWS-THE WOODLANDS
Job Phone: 763-219-7102
Location Address: 53 BLARE DR
Type: RF - REROOF
Issue Date: 11/16/2022
NOC: RECORDED
Applicant name: CHRISTOPHER RAY MCKINNEY
Owner: CRANE DAVID A

Address

53 BLARE DRIVE

PALM COAST, FL 32137

Lot: 0030
Contracted Stated Job Value: ¤21,500.00
Job Description: Roof Replacement
Type: CN

Contractor

ROOF PROS STORM DIVISION INC
Status Location Address Mailing Address State License Number Phone Fax
ACTIVE

3501-B N PONCE DELEON BLVD

ST. AUGUSTINE, FL 32084

UNIT 357

ST. AUGUSTINE , FL 32084

CCC1330201 (Exp: 08/31/2026) 888-844-4245 888-487-8856

Inspection History

Type Request Date Result Inspector
ROOF FINAL 11/08/2023 APPROVED BTAYLOR
Note: Inspector Notes from Inspection 2468 11/30/2022 - PREVIOUS INSPECTION NOTES 11/29/2022 - PREVIOUS INSPECTION NOTES NOT READY FOR MIDROOF INSPECTION. 3 WORKERS TEARING OFF. RENAILING NEEDS TO BE DONE BEFORE PAPER IS INSTALLED. SHINGLES HAVE TO BE HAND CARRIED UP A LADDER ONCE RENAILING, PAPER AND VALLEYS ARE INSTALLED. 11-30-22 Need revision for materials and method of application. The work does not match the approved proposed documents.. The documents call fo emtire roof deck seams to pe taped and then the entire roof to be covered with double coverage. This was not done, the roof has two rows of peel and stick at the bottom and the rest is covered with two layers of synthetic with no tap applied. 12-01-22 still Need revision for materials and method of application. (revision needed by final) The work does not match the approved proposed documents.. The documents call fo entire roof deck seams to be taped and then the entire roof to be covered with double coverage. This was not done, the roof has two rows of peel and stick at the bottom and the rest is covered with two layers of synthetic with no tap applied. (Must show both underlayments used)(procede at contractors risk).
ROOF AFFIDAVIT 05/16/2023 APPROVED STHOMAS
ROOF IN PROGRESS- MIDROOF 12/01/2022 APPROVED - AS NOTED LMILLER
Note: 11/30/2022 - PREVIOUS INSPECTION NOTES 11/29/2022 - PREVIOUS INSPECTION NOTES NOT READY FOR MIDROOF INSPECTION. 3 WORKERS TEARING OFF. RENAILING NEEDS TO BE DONE BEFORE PAPER IS INSTALLED. SHINGLES HAVE TO BE HAND CARRIED UP A LADDER ONCE RENAILING, PAPER AND VALLEYS ARE INSTALLED. 11-30-22 Need revision for materials and method of application. The work does not match the approved proposed documents.. The documents call fo emtire roof deck seams to pe taped and then the entire roof to be covered with double coverage. This was not done, the roof has two rows of peel and stick at the bottom and the rest is covered with two layers of synthetic with no tap applied. 12-01-22 still Need revision for materials and method of application. (revision needed by final) The work does not match the approved proposed documents.. The documents call fo entire roof deck seams to be taped and then the entire roof to be covered with double coverage. This was not done, the roof has two rows of peel and stick at the bottom and the rest is covered with two layers of synthetic with no tap applied. (Must show both underlayments used)(procede at contractors risk).
ROOF IN PROGRESS- MIDROOF 11/30/2022 Disapproved - NO FEE LMILLER
Note: 11/29/2022 - PREVIOUS INSPECTION NOTES NOT READY FOR MIDROOF INSPECTION. 3 WORKERS TEARING OFF. RENAILING NEEDS TO BE DONE BEFORE PAPER IS INSTALLED. SHINGLES HAVE TO BE HAND CARRIED UP A LADDER ONCE RENAILING, PAPER AND VALLEYS ARE INSTALLED. 11-30-22 Need revision for materials and method of application. The work does not match the approved proposed documents.. The documents call fo emtire roof deck seams to pe taped and then the entire roof to be covered with double coverage. This was not done, the roof has two rows of peel and stick at the bottom and the rest is covered with two layers of synthetic with no tap applied.
ROOF IN PROGRESS- MIDROOF 11/29/2022 Disapproved -FEE REQUIRED FWILLIS
Note: NOT READY FOR MIDROOF INSPECTION. 3 WORKERS TEARING OFF. RENAILING NEEDS TO BE DONE BEFORE PAPER IS INSTALLED. SHINGLES HAVE TO BE HAND CARRIED UP A LADDER ONCE RENAILING, PAPER AND VALLEYS ARE INSTALLED.

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION RESIDENTIAL ¤40.00 11/07/2023
SURCHARGE FS 533.721 ¤2.00 11/16/2022
SURCHARGE - FS 468.631 ¤2.00 11/16/2022
ADJUSTMENT 50% (¤45.25) 11/16/2022
ADMINISTRATIVE RESIDENTIAL ¤30.00 11/16/2022
INSPECTION - RESIDENTIAL ¤60.50 11/16/2022
Fees Total Due: ¤0.00 Total Paid: ¤89.25