I want to search for...
Permit #2022111029
Permit Details
Status: COED
| Parcel Id: 07-11-31-7002-00030-0130 |
| Block: 00030 |
| Subdivision: 2218 - SECTION 2-FLORIDA PARK |
| Job Phone: 386-313-6922 |
| Location Address: 3 FLORIDA PARK DR |
| Type: CIA - COMMERCIAL INTERIOR EXTERIOR ALTERATION |
| Issue Date: 05/01/2023 |
| NOC: RECORDED |
| Applicant name: FRANK JOSEPH WHALEN |
| Owner: JETS DAY CARE INC |
|
Address P.O. BOX 1255 BUNNELL, FL 32110 |
| Lot: 0130 |
| Contracted Stated Job Value: ¤35,000.00 |
| Job Description: UNIT D - INTERIOR ALTERATION (JETS DAY CARE INC.) |
| Type: CN |
Contractor
EAST COAST BUILDING CORP
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
321 BRIARWOOD DRIVE BUNNELL, FL 32110 |
CGC057860 (Exp: 08/31/2026) | 386-313-6922 | 386-313-6922 |
Sub Contractors
MICHAEL C PASTERNAK
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
748 N RIDGEWOOD AVE ORMOND BEACH, FL 32174 |
EC13005663 (Exp: 08/31/2026) | 386-671-7474 | 386-671-7670 |
RICHARD GARY WILSON JR
| Status | Location Address | Mailing Address | State License Number | Phone |
| ACTIVE |
1504 OLD MOODY BLVD BUNNELL, FL 32110 |
UNIT 6 BUNNELL, FL 32110 |
CAC1817645 (Exp: 08/31/2026) | 386-586-6290 |
SCOTT PATRICK RAYMOND
| Status | Location Address | State License Number |
| ACTIVE |
61 FRENEAU LN PALM COAST, FL 32137 |
RF11067787 (Exp: 08/31/2027) |
Inspection History
| Type | Request Date | Result | Inspector |
| INSULATION | 08/07/2023 | APPROVED | FWILLIS |
| BUILDING FINAL | 08/07/2023 | FINAL APPROVED | FWILLIS |
| FIRE FINAL | 08/03/2023 | APPROVED | RMARTIN |
| U - UTILITY COMMERCIAL FINAL | 08/03/2023 | FINAL APPROVED | DHANEY |
| HVAC FINAL | 08/01/2023 | Disapproved -FEE REQUIRED | CPISCITELLI |
| Note: 1. Breakers in panel need to be labeled. There are 2 AHU and no ODU. 2. AHU heater not marked. Could not verify breaker | |||
| HVAC FINAL | 08/01/2023 | FINAL APPROVED | CPISCITELLI |
| Note: Facetime inspection | |||
| PLUMBING FINAL | 07/31/2023 | APPROVED | MGIBSON |
| Note: 7/24/2023 - PREVIOUS INSPECTION NOTES 1. No hot water. 2. Washing machine stand pipe Install washing maching or cap the standpipe. 3. Kitchen sink drain tee / p-trap cannot be of the flexible type. 7/10/2023 - PREVIOUS INSPECTION NOTES | |||
| PLUMBING FINAL | 07/24/2023 | Disapproved - NO FEE | JWALKER |
| Note: 1. No hot water. 2. Washing machine stand pipe Install washing maching or cap the standpipe. 3. Kitchen sink drain tee / p-trap cannot be of the flexible type. 7/10/2023 - PREVIOUS INSPECTION NOTES | |||
| ELECTRIC FINAL | 07/24/2023 | APPROVED - AS NOTED | RMARTIN |
| Note: check quad outlets in main area on fire final for tamper 7/12/2023 - PREVIOUS INSPECTION NOTES need to frame out above electrical panel, need gfci in attic for ahu, need emergency light in left room | |||
| HVAC FINAL | 07/12/2023 | Disapproved - NO FEE | CPISCITELLI |
| Note: 1. Need to move location of attic access. High votage line runs through center of existing location. 2. Need plywood in front of AHU. 3. Need service oulet 4. Need to soffit cap for bathfan. 5. Need to reseal bottom of several duct connections and bathroom line is kinked 6. Need to install lineset cover over lineset on wall. 7. Need to label breaker panel for AC unit 8. Need to shift ODU toward electrical closet for access and serviceability thru fence. | |||
| ELECTRIC 2ND ROUGH | 07/12/2023 | APPROVED - AS NOTED | RMARTIN |
| Note: need to frame out above electrical panel, need gfci in attic for ahu, need emergency light in left room | |||
| ELECTRIC FINAL | 07/12/2023 | CANCELLED BY APPLICANT | RMARTIN |
| Note: need to frame out above electrical panel, need gfci in attic for ahu, need emergency light in left room | |||
| PLUMBING FINAL | 07/10/2023 | CANCELLED BY APPLICANT | MGIBSON |
| PLUMBING FINAL | 07/06/2023 | CANCELLED BY APPLICANT | WEB |
| HVAC FINAL | 07/06/2023 | CANCELLED BY APPLICANT | WEB |
| Note: Inspector Notes from Inspection 3140 1. Need to move location of attic access. High votage line runs through center of existing location. 2. Need to have metal on bottom of return box in ceiling. 3. Need plywood in front of AHU. 4. Need service oulet and light in attic near AHU. 5. Need to vent bathfan. 6. Need to reseal bottom of several duct connections and bathroom line is kinked | |||
| HVAC ROUGH | 06/16/2023 | APPROVED - AS NOTED | CPISCITELLI |
| Note: 1. Need to move location of attic access. High votage line runs through center of existing location. 2. Need to have metal on bottom of return box in ceiling. 3. Need plywood in front of AHU. 4. Need service oulet and light in attic near AHU. 5. Need to vent bathfan. 6. Need to reseal bottom of several duct connections and bathroom line is kinked | |||
| MONOLITHIC SLAB | 06/16/2023 | APPROVED | FWILLIS |
| FRAMING | 06/16/2023 | APPROVED | FWILLIS |
| PLUMBING 1ST ROUGH | 06/07/2023 | APPROVED | MGIBSON |
Review History
| Department | Status | Date In | Date Out |
| MECH | COMPLETE | 04/18/2023 | 04/19/2023 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| FI1 | COMPLETE | 03/24/2023 | 03/30/2023 |
| Note: Released By: LEE MILLER - (386)986-3783 - WMILLER@PALMCOASTGOV.COM | |||
| MECH | HOLD | 03/24/2023 | 03/27/2023 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM 2. Provide Ventilation calculation per Table 403.3.1.1 FBC Mechanical 2020 7Th edition (Second Request) Show calculation formula from Table 403.3.1. Update duct layout and CFM requirements to correspond to formula | |||
| BLD | COMPLETE | 03/24/2023 | 04/10/2023 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| ELEC | COMPLETE | 03/24/2023 | 04/03/2023 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| PLUM | COMPLETE | 03/24/2023 | 04/10/2023 |
| Note: Released By: PATRICK BUCKLEY - (386)986-3786 - PBUCKLEY@PALMCOASTGOV.COM | |||
| ELEC | HOLD | 03/21/2023 | 03/21/2023 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Corrections to this permit need to be in person as origionally applied for. | |||
| MECH | HOLD | 03/21/2023 | 03/21/2023 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Corrections to this permit need to be in person as origionally applied for. | |||
| FI1 | HOLD | 03/21/2023 | 03/21/2023 |
| Note: Held By: LEE MILLER - (386)986-3783 - WMILLER@PALMCOASTGOV.COM All comments remain unresolved the revised plans were not uploaded. (the energy calcs were uploaded twice with no new plans uploaded. All comments below per the 2020 Florida Fire Prevention Code, 2020 FBC, and or 2020 Existing Building Code Please provide a written response to each comment below in a response letter and provide clouded response changes on plan sheets and add page locations for each response. 1. Please include a Code Analysis utilizing the FBC Existing Building Code 7th edition chapter 7, 8, for the alteration. 2. Please include FFPC 7th edition in the code analysis 3. Please include FBC 7th edition in the code analysis 4. Please include FBC Existing Building Code 7th edition in the code analysis 5. Please note the space will be required to have a fire sprinkler system or exit doors leading directly to a public way from each classroom per FBC 903.2.6 Exception (2). Be advised classroom 2 will be treated as a separate classroom and will drive the need for Sprinklers or an exit door must be added. 6. Please advise if there will be access provided through the current firewall or if access will be through separate exit doors. The Current plan provided shows no access between the two I-4 occupancies. If access will be opened through the Firewall the Details for the opening will need to be uploaded. 7. If the space will have an access from the adjacent occupancy through the firewall, please provide the square footage for the entire building. If no access will be provided thought the firewall please show the square footage for the unit under change of occupancy. 8. Please include a clearly defined description of the work to be performed, the work area, and any existing areas that will not be affected by the changes including fire sprinklers (if any) and or alarm system. 9. Please place a note on the plan indicating separate permits are required for Fire Alarms, also if fire sprinklers will be added, place a similar note for fire sprinklers. 10. Please provide travel distance from the most remote location to the exit 11. Please provide travel distance from the most remote location to the required fire extinguishers per FFPC 1, 13.6.3.2.1.2.2 12. Additional comments are likely after resubmittal. | |||
| BLD | HOLD | 03/21/2023 | 03/21/2023 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Corrections to this permit need to be in person as origionally applied for. | |||
| PLUM | HOLD | 03/21/2023 | 03/21/2023 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Corrections to this permit need to be in person as origionally applied for. | |||
| BLD | HOLD | 11/23/2022 | 12/07/2022 |
| Note: Held By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM All comments below per the 2020 Florida Building Code PLAN REVIEW COMMENTS: 1. Provide compliance with Chapter 10 2020 7th Edition Florida Building Existing. Existing unit occupancy is Business and the proposed is Institutional Group I-4. 2. Provide if this will be two separate Day Care Centers or will adjoined. 3. Provide direct Exit from Classroom #2 or provide a fire sprinkler system. 4. Provide how the bathroom complies with Section 806 for accessibility. | |||
| DSD | COMPLETE | 11/23/2022 | 11/28/2022 |
| Note: Released By: JACQUELINE GONZALEZ - (386)986-3751 - JGONZALEZ@PALMCOASTGOV.COM | |||
| ELEC | HOLD | 11/23/2022 | 12/05/2022 |
| Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. All outlet must be tamper resistant. NEC 2017 406.12 2. Outlets specified in NEC 2017 210.8 (B) need to be GFCI protected. 3 Provide existing electrical layout. | |||
| FI1 | HOLD | 11/23/2022 | 12/07/2022 |
| Note: Held By: LEE MILLER - (386)986-3783 - WMILLER@PALMCOASTGOV.COM All comments below per the 2020 Florida Fire Prevention Code, 2020 FBC, and or 2020 Existing Building Code Please provide a written response to each comment below in a response letter and provide clouded response changes on plan sheets and add page locations for each response. 1. Please include a Code Analysis utilizing the FBC Existing Building Code 7th edition chapter 7, 8, for the alteration. 2. Please include FFPC 7th edition in the code analysis 3. Please include FBC 7th edition in the code analysis 4. Please include FBC Existing Building Code 7th edition in the code analysis 5. Please note the space will be required to have a fire sprinkler system or exit doors leading directly to a public way from each classroom per FBC 903.2.6 Exception (2). Be advised classroom 2 will be treated as a separate classroom and will drive the need for Sprinklers or an exit door must be added. 6. Please advise if there will be access provided through the current firewall or if access will be through separate exit doors. The Current plan provided shows no access between the two I-4 occupancies. If access will be opened through the Firewall the Details for the opening will need to be uploaded. 7. If the space will have an access from the adjacent occupancy through the firewall, please provide the square footage for the entire building. If no access will be provided thought the firewall please show the square footage for the unit under change of occupancy. 8. Please include a clearly defined description of the work to be performed, the work area, and any existing areas that will not be affected by the changes including fire sprinklers (if any) and or alarm system. 9. Please place a note on the plan indicating separate permits are required for Fire Alarms, also if fire sprinklers will be added, place a similar note for fire sprinklers. 10. Please provide travel distance from the most remote location to the exit 11. Please provide travel distance from the most remote location to the required fire extinguishers per FFPC 1, 13.6.3.2.1.2.2 12. Additional comments are likely after resubmittal. | |||
| MECH | HOLD | 11/23/2022 | 12/06/2022 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM 1. Provide Heatload Calculation per C403.2.1 FBC Energy Conservation 2020 7Th edition 2. Provide Ventilation calculation per Table 403.3.1.1 FBC Mechanical 2020 7Th edition 3. Provide existing duct layout showing supply, return, fresh air, exhaust and equipment model numbers. Complete review was not completed. Additional comments may be generated after resubmittal | |||
| PLUM | HOLD | 11/23/2022 | 12/07/2022 |
| Note: Held By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM All comments below per the 2020 Florida Building Code – Plumbing PLAN REVIEW COMMENTS: 1. Per Table 403.1, a shower is required. | |||
| UD1 | COMPLETE | 11/23/2022 | 11/28/2022 |
| Note: Released By: CHRIS JOHNSON - (386)986-2384 - CJOHNSON@PALMCOASTGOV.COM |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| CONTRACTOR CHANGE | ¤20.00 | 07/10/2023 |
| CONTRACTOR CHANGE | ¤20.00 | 06/19/2023 |
| CONTRACTOR CHANGE | ¤20.00 | 06/19/2023 |
| SURCHARGE FS 533.721 | ¤2.00 | 05/01/2023 |
| SURCHARGE - FS 468.631 | ¤2.01 | 05/01/2023 |
| SITE PLAN 30 | ¤30.00 | 05/01/2023 |
| ADJUSTMENT 50% | (¤100.00) | 05/01/2023 |
| ADMINISTRATIVE - COMMERCIAL | ¤75.00 | 05/01/2023 |
| INSPECTION COMMERCIAL | ¤60.00 | 05/01/2023 |
| PLAN REVIEW - COMMERCIAL | ¤65.00 | 05/01/2023 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤194.01 |