I want to search for...
Permit #2022120008
Permit Details
Status: FINAL
| Parcel Id: 07-11-31-7034-00620-0140 |
| Block: 00620 |
| Subdivision: 2165 - SECTION 34-EASTHAMPTON |
| Job Phone: (386)527-6203 |
| Location Address: 6 ELLSWORTH DR |
| Type: PO - POOL |
| Issue Date: 12/14/2022 |
| NOC: RECORDED |
| Applicant name: BRIAN ROBERT LENOIS |
| Owner: RONDEL DMITRIY & YANA H&W |
|
Address 1995 ALLAN AVE YORKTOWN HEIGHTS, NY 10598 |
| Lot: 0140 |
| Contracted Stated Job Value: ¤60,047.00 |
| Job Description: POOL WITH DECK AND SCREEN ENCLOSURE |
| Type: CN |
Contractor
ARTESIAN POOLS OF EAST FLORIDA, INC.
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
762 S NOVA ROAD DAYTONA BEACH , FL 32114 |
CPC1456573 (Exp: 08/31/2026) | (386)586-5569 | (386)258-3702 |
Sub Contractors
JEFFREY ADAM MCGREGOR
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
1312 YORKTOWN STREET DELAND , FL 32724 |
EC13005662 (Exp: 08/31/2026) | 386-736-7475 | 386-785-1503 |
BRIAN THOMAS KULL
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
18 STRAFORD PLACE PORT ORANGE, FL 32128 |
CGC1504924 (Exp: 08/31/2026) | 386-682-9554 | (386)258-8042 |
Inspection History
| Type | Request Date | Result | Inspector |
| POOL FINAL | 11/08/2024 | FINAL APPROVED | PKNAPIK |
| U -UTILITY RESIDENTIAL FINAL | 11/05/2024 | FINAL APPROVED | LFITZGERALD |
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 11/04/2024 | APPROVED - AS NOTED | FSLADISH |
| Note: 11/4/24 CORRECTIONS MADE IN THE FIELD HAVE CORRECTED ELEVATIONS. APPROVING AS NOTED 4/11/2024 - PREVIOUS INSPECTION NOTES 04/11/24 AS PRIOR NOTES INDICATED AND BOTH THE SURVEYS SUBMITTED THE LEFT PROPERTY LINE WHERE YOU MADE ENTRANCE HAS A 27.05 26.70 THEN A 26.95 THIS IS MORE THAN THE .10 TOLERNACE ALLOWED AND NEEDS TO BE CORRECTED. THERE HAS BEEN NO ELEVATION CHANGES SINCE FIRST SURVEY WAS DISSAPROVED. | |||
| ROW FIELD SURVEY /GRADING CERTIFICATION | 11/04/2024 | APPROVED | FSLADISH |
| Note: 11/4/24 CORRECTIONS MADE AT THE TIME OF THIS INSPECTION. APPROVING AS NOTED. Inspector Notes from Inspection 9463 11/4/24 CORRECTIONS MADE IN THE FIELD HAVE CORRECTED ELEVATIONS. APPROVING AS NOTED 4/11/2024 - PREVIOUS INSPECTION NOTES 04/11/24 AS PRIOR NOTES INDICATED AND BOTH THE SURVEYS SUBMITTED THE LEFT PROPERTY LINE WHERE YOU MADE ENTRANCE HAS A 27.05 26.70 THEN A 26.95 THIS IS MORE THAN THE .10 TOLERNACE ALLOWED AND NEEDS TO BE CORRECTED. THERE HAS BEEN NO ELEVATION CHANGES SINCE FIRST SURVEY WAS DISSAPROVED. 1/2/2024 - PREVIOUS INSPECTION NOTES 1/2/24 UPON WALKING PROPERTY DETERMINED WHERE YOU ACCESSED THE SITE ON THE LEFT SIDE WILL NEED TO BE GRADED AS TO NOT IMPACT ADJOING LOT. THIS IS ALSO INDICATED IN THE SURVEY ELEVATION NUMBERS. FRONT SWALE ON LEFT SIDE WILL NEED TO BE REPAIRED, SODDED AND GRADE MATCHED BEFORE ROW FINAL PASSAGE. ______________________________________________________________________________________________________________________ Inspector Notes from Inspection 9463 1/2/24 SURVEY SHOWS WATER FALLING ONTO ADJOINING PROPERTY WILL DETERMINE DURING FIELD SURVEY. | |||
| ROW - FINAL INSPECTION | 11/04/2024 | APPROVED | FSLADISH |
| Note: 11/4/24 AT THE TIME OF THIS INSPECTIONS ALL COPC REQUIREMENTS WERE MET, NEITHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED | |||
| ROW- PROJECT STATUS | 09/05/2024 | APPROVED | FSLADISH |
| Note: 9/5/24 MET WITH BRIAN AND DISCUSSED MAKING THE LEFT SIDE PROPERTY LINE FROM THE 27.05 ELEVATION MARK FALL TO 26.85 TO 26.80 TOWARD THE BACK CORNER TO CREATE INCREMENTAL POSITIVE FLOW. LET HIM KNOW TO FEEL FRREE TO REACH OUT FOR ASSISTANCE IF NEEDED OR WHEN IT IS COMPLETED WE COULD TAKE A LOOK AT IT TO MAKE SURE IT WILL WORK BEFORE SUBMITTING FOR INSPECTION. | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 04/11/2024 | Disapproved -FEE REQUIRED | TPOLACEK |
| Note: 04/11/24 AS PRIOR NOTES INDICATED AND BOTH THE SURVEYS SUBMITTED THE LEFT PROPERTY LINE WHERE YOU MADE ENTRANCE HAS A 27.05 26.70 THEN A 26.95 THIS IS MORE THAN THE .10 TOLERNACE ALLOWED AND NEEDS TO BE CORRECTED. THERE HAS BEEN NO ELEVATION CHANGES SINCE FIRST SURVEY WAS DISSAPROVED. | |||
| ROW FIELD SURVEY /GRADING CERTIFICATION | 01/02/2024 | Disapproved - NO FEE | FSLADISH |
| Note: 1/2/24 UPON WALKING PROPERTY DETERMINED WHERE YOU ACCESSED THE SITE ON THE LEFT SIDE WILL NEED TO BE GRADED AS TO NOT IMPACT ADJOING LOT. THIS IS ALSO INDICATED IN THE SURVEY ELEVATION NUMBERS. FRONT SWALE ON LEFT SIDE WILL NEED TO BE REPAIRED, SODDED AND GRADE MATCHED BEFORE ROW FINAL PASSAGE. ______________________________________________________________________________________________________________________ Inspector Notes from Inspection 9463 1/2/24 SURVEY SHOWS WATER FALLING ONTO ADJOINING PROPERTY WILL DETERMINE DURING FIELD SURVEY. | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 01/02/2024 | APPROVED - AS NOTED | FSLADISH |
| Note: 1/2/24 SURVEY SHOWS WATER FALLING ONTO ADJOINING PROPERTY WILL DETERMINE DURING FIELD SURVEY. | |||
| ELECTRIC AND ALARM | 10/24/2023 | APPROVED - AS NOTED | RSIMS |
| Note: 10/24/23: You will need to have weed/grass overgrowth behind & around equipment, at piping, etc. completely removed prior to Pool final inspection so that ground, etc. can be fully verified. 9/21/2023 - PREVIOUS INSPECTION NOTES 9/21/23: Need overgrowth of grass/weeds around pool equipment removed for inspections. 1). Overgrowth at pool pump & heat pump is preventing verification of proper ground installation. 2). Heat pump is missing all 4 approved anchors. M1307.1 & M1307.2 3). Base/pad for the Heatpump is not labeled as approved for use in this application/area. (Must be a hurricane rated pad) 4). Base pad is only 2" thick and the top is level with/under grade. Minimum 3" ground clearance is required per FBC 1305.1.4.1. | |||
| ELECTRIC AND ALARM | 09/21/2023 | Disapproved -FEE REQUIRED | RSIMS |
| Note: 9/21/23: Need overgrowth of grass/weeds around pool equipment removed for inspections. 1). Overgrowth at pool pump & heat pump is preventing verification of proper ground installation. 2). Heat pump is missing all 4 approved anchors. M1307.1 & M1307.2 3). Base/pad for the Heatpump is not labeled as approved for use in this application/area. (Must be a hurricane rated pad) 4). Base pad is only 2" thick and the top is level with/under grade. Minimum 3" ground clearance is required per FBC 1305.1.4.1. | |||
| POOL DECK | 05/18/2023 | APPROVED | RSIMS |
| Note: 5/12/2023 - PREVIOUS INSPECTION NOTES 5/12/23: Items 1 and 4 are not fully resolved. Minor cave-in at footer near permit box. Grass & debris still exist in the deck area. Need to remove grass in the deck and footer areas along with outside of the footer as required by FBC R404. 5/4/2023 - PREVIOUS INSPECTION NOTES 5/4/23: Safety fence is not installed properly. (falling down throughout). 1). Pool deck area has lots of debris & trash throughout along with weeds growing in a large area. 2). The footer is not consistently 12" wide x 8" deep. and is missing the outside form boards. 3). The plans call for (2) #3 rebar consistent throughout yet (1) # 5 is installed. 4). There is debris & minor dirt cave in at multiple locations in the footer. | |||
| POOL DECK | 05/12/2023 | Disapproved -FEE REQUIRED | RSIMS |
| Note: 5/12/23: Items 1 and 4 are not fully resolved. Minor cave-in at footer near permit box. Grass & debris still exist in the deck area. Need to remove grass in the deck and footer areas along with outside of the footer as required by FBC R404. 5/4/2023 - PREVIOUS INSPECTION NOTES 5/4/23: Safety fence is not installed properly. (falling down throughout). 1). Pool deck area has lots of debris & trash throughout along with weeds growing in a large area. 2). The footer is not consistently 12" wide x 8" deep. and is missing the outside form boards. 3). The plans call for (2) #3 rebar consistent throughout yet (1) # 5 is installed. 4). There is debris & minor dirt cave in at multiple locations in the footer. | |||
| POOL DECK | 05/04/2023 | Disapproved -FEE REQUIRED | RSIMS |
| Note: 5/4/23: Safety fence is not installed properly. (falling down throughout). 1). Pool deck area has lots of debris & trash throughout along with weeds growing in a large area. 2). The footer is not consistently 12" wide x 8" deep. and is missing the outsidxe form boards. 3). The plans call for (2) #3 rebar consistent throughout yet (1) # 5 is installed. 4). There is debris & minor dirt cave in at multiple locations in the footer. | |||
| STEEL AND GROUND | 01/06/2023 | APPROVED | JWALKER |
Review History
| Department | Status | Date In | Date Out |
| BADMIN | INFORMATION | 12/14/2023 | 12/14/2023 |
| Note: Marked INFORMATION By: MICHELLE RAMOS - (386)986-3780 - MRAMOS@PALMCOASTGOV.COM NOC expired. Unable to process final survey. Please upload current NOC and upload final survey. | |||
| BLD | COMPLETE | 10/10/2023 | 10/10/2023 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 12/13/2022 | 12/14/2022 |
| Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM | |||
| BLD | HOLD | 12/01/2022 | 12/05/2022 |
| Note: Held By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM All comments below per the 2020 Florida Building Code REVIEW COMMENTS: 1. A revision to the City of Palm Coast Poll Safety Form is required. Provide two methods of compliance. | |||
| ELEC | COMPLETE | 12/01/2022 | 12/01/2022 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 12/01/2022 | 12/01/2022 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 12/01/2022 | 12/07/2022 |
| Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 12/01/2022 | 12/01/2022 |
| Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| EXTENSION | ¤40.00 | 11/06/2024 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 11/06/2024 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 11/06/2024 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 11/06/2024 |
| SW ENG REINSPECTION 20 | ¤20.00 | 11/06/2024 |
| SW ENG - REVIEW 20 | ¤20.00 | 12/14/2022 |
| SITE PLAN 30 | ¤30.00 | 12/14/2022 |
| SURCHARGE FS 533.721 | ¤2.00 | 12/14/2022 |
| SURCHARGE - FS 468.631 | ¤2.00 | 12/14/2022 |
| SW ENG INSPECTION 40 | ¤40.00 | 12/14/2022 |
| INSPECTION- POOL | ¤160.00 | 12/14/2022 |
| PLAN REVIEW - RESIDENTIAL | ¤65.00 | 12/14/2022 |
| ADJUSTMENT 50% | (¤127.50) | 12/14/2022 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 12/14/2022 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤401.50 |