Permit #2022120516
Permit Details
Status: FINAL
| Parcel Id: 07-11-31-7011-000C0-0090 |
| Block: 000C0 |
| Subdivision: 1240 - LUPI PLAZA |
| Job Phone: (386)672-8688 |
| Location Address: 1290 PALM COAST PKWY NW |
| Type: CM - COMMERCIAL MECHANICAL |
| Issue Date: 12/15/2022 |
| NOC: Unknown |
| Applicant name: SHAWN MICHAEL HISS |
| Owner: INTRACOASTAL BANK |
|
Address 1290 PALM COAST PKWY NW PALM COAST, FL 32137 |
| Lot: 0090 |
| Contracted Stated Job Value: ¤7,400.00 |
| Job Description: HVAC-LIKE FOR LIKE TONNAGE |
| Type: CN |
Contractor
CLIMATE CONTROL HEATING & AIR CONDITIONING INC
| Status | Location Address | State License Number | Phone |
| ACTIVE |
1315 LPGA BLVD HOLLY HILL, FL 32117 |
CAC1813585 (Exp: 08/31/2026) | (386)672-8688 |
Inspection History
| Type | Request Date | Result | Inspector |
| HVAC FINAL | 04/28/2023 | FINAL APPROVED | CPISCITELLI |
| Note: Google duo inspection 4/24/2023 - PREVIOUS INSPECTION NOTES 3/23/2023 - PREVIOUS INSPECTION NOTES 1. Need to number AHU and ODU. 2. Need disconnect at AHU. Panel downstairs 3. Could not verify breakers in panel. Also AHU calls for 60 AMP. There is no 60 AMP in panel | |||
| HVAC FINAL | 04/25/2023 | CANCELLED BY APPLICANT | TSTAUFFACHER |
| Note: 3/23/2023 - PREVIOUS INSPECTION NOTES 1. Need to number AHU and ODU. 2. Need disconnect at AHU. Panel downstairs 3. Could not verify breakers in panel. Also AHU calls for 60 AMP. There is no 60 AMP in panel | |||
| HVAC FINAL | 03/23/2023 | Disapproved -FEE REQUIRED | CPISCITELLI |
| Note: 1. Need to number AHU and ODU. 2. Need disconnect at AHU. Panel downstairs 3. Could not verify breakers in panel. Also AHU calls for 60 AMP. There is no 60 AMP in panel |
Review History
| Department | Status | Date In | Date Out |
| MECH | COMPLETE | 12/13/2022 | 12/13/2022 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 12/13/2022 | 12/13/2022 |
| Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION - COMMERCIAL | ¤60.00 | 04/19/2023 |
| SURCHARGE FS 533.721 | ¤2.00 | 12/15/2022 |
| SURCHARGE - FS 468.631 | ¤2.00 | 12/15/2022 |
| SITE PLAN 15 | ¤15.00 | 12/15/2022 |
| ADJUSTMENT 50% | (¤83.75) | 12/15/2022 |
| ADMINISTRATIVE - COMMERCIAL | ¤75.00 | 12/15/2022 |
| INSPECTION - MECHANICAL | ¤60.00 | 12/15/2022 |
| PLAN REVIEW - MISC 32.50 | ¤32.50 | 12/15/2022 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤162.75 |