I want to search for...
Permit #2022120534
Permit Details
Status: COED
| Parcel Id: 07-11-31-7009-00450-0120 |
| GARAGE: 640 sqft |
| OPENED PORCH (WITH ROOF) : 741 sqft |
| CONDITIONED SPACE: 2594 sqft |
| Total Square Footage: 3975 sqft |
| Block: 00450 |
| Subdivision: 2208 - SECTION 9-FLORIDA PARK |
| Job Phone: 386-338-1859 |
| Location Address: 74 FENIMORE LN |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 01/09/2023 |
| NOC: RECORDED |
| Applicant name: SOPHAN KES |
| Owner: NONG CHRIYA & RINDY NONG W&H |
|
Address 35 BUNKER KNOLLS LANE PALM COAST, FL 32137 |
| Lot: 0120 |
| Contracted Stated Job Value: ¤300,000.00 |
| Job Description: Single Family Residence |
| Type: CN |
Contractor
KES CONSTRUCTION, INC
| Status | Location Address | State License Number |
| ACTIVE |
42 OAKLEAF WAY PALM COAST, FL 32137 |
CBC1264797 (Exp: 08/31/2026) |
Sub Contractors
ROBERT JAMES BARROW JR
| Status | Location Address | Mailing Address | State License Number | Phone |
| ACTIVE |
2323 N STATE ST BUNNELL, FL 32110 |
UNIT 126 BUNNELL, FL 32110 |
CAC1817890 (Exp: 08/31/2026) | 386-627-5500 |
CHRISTOPHER I HALL
| Status | Location Address | State License Number | Phone |
| ACTIVE |
60 COOPER LANE PALM COAST, FL 32137 |
EC13008029 (Exp: 08/31/2028) | 386-225-1937 |
PEDRO DANIEL CHINCHILLA
| Status | Location Address | State License Number | Phone |
| ACTIVE |
324 COVENT GARDENS PL DELTONA, FL 32725 |
CCC1333997 (Exp: 08/31/2026) | 386-679-6228 |
GIOVANNI DISARRO
| Status | Location Address | State License Number |
| INACTIVE |
107 BURROUGHS DRIVE PALM COAST, FL 32137 |
CFC1430761 (Exp: 08/31/2026) |
Inspection History
| Type | Request Date | Result | Inspector |
| U-CROSS CONNECTION | 03/28/2024 | APPROVED | DHANEY |
| ROW - STORMWATER FINAL | 03/27/2024 | APPROVED - AS NOTED | FSLADISH |
| Note: 3/27/24 REQUIRED CORRECTIONS HAVE BEEN MADE AT THE TIME OF THIS INSPECTION. At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved. ________________________________________________________________________________________________________________________ 3/26/2024 - PREVIOUS INSPECTION NOTES 3/25/2024 - PREVIOUS INSPECTION NOTES 3/25/24 SPOKE WITH BUILDER THEY WILL NEED TO REPAIR, SLOPE, GRADE AND SOD DISTURBED AREA ON THE LEFT SIDE SWALE PROPERTY LINE. NOT GOING TO FEE YOU TODAY AS I WAS ALREADY HERE FOR THE AFTERPUR INSPECTION.. ___________________________________________________________________________________________________________________________ Inspector Notes from Inspection 9465 3/21/24 WHILE YOU HAVE LOWERED THE REAR DRAINAGE AREA YOU WILL NEED TO LOWER THE AREAS OUTLINED IN WHITE FOR THE DRAINAGE TO SHED AROUND THE CORNERS AND FORWARD TO THE FRONT SWALE. I AM APPROVING THIS FIELD SURVEY AS NOTED TO HELP YOU MOVE FORWARD. PLEASE MAKE THE REQUIRED CORRECTIONS. THERE MAY BE OTHER CORRECTIONS REQUIRED BEFORE ROW FINAL PASSAGE THIS IS NOT INTENDED TO POINT OUT ALL NEEDED CORRECTIONS AS CONDITION MAY CHANGE PRIOR TO YOUR NEXT INSPECTION. _________________________________________________________________________________________________________________________ 3/19/2024 - PREVIOUS INSPECTION NOTES 3/19/24 UPON WALKING PROPERTY DETERMINED THAT THE REAR FALL OFF OF THE PATIO IN THE REAR IS SHOWING 1 TENTH FALL 22.90 TO A 22.80 AND THE REAR PROPERTY LINE IS SHOWING SHOWING 23.30. THIS WILL CAUSE WATER TO FALL BACK ON THE PATIO DURING HARD RAIN. WILL NEED TO CREATE A DEEPER SWALE TO CONTAIN AND SHED WATER AWAY FROM STRUCTURE AND AROUND CORNER. COPC STANDARDS ARE 6 TENTHS FALL FROM STUCTURE TO 10' OUT. Drainage from the structure Section 300, Drawing 300.D, Drainage from the structure is to be a 6 inch (5%) minimum slope for the first 10’ | |||
| ROW - STORMWATER FINAL | 03/26/2024 | CANCELLED BY APPLICANT | FSLADISH |
| Note: 3/25/2024 - PREVIOUS INSPECTION NOTES 3/25/24 SPOKE WITH BUILDER THEY WILL NEED TO REPAIR, SLOPE, GRADE AND SOD DISTURBED AREA ON THE LEFT SIDE SWALE PROPERTY LINE. NOT GOING TO FEE YOU TODAY AS I WAS ALREADY HERE FOR THE AFTERPUR INSPECTION.. ___________________________________________________________________________________________________________________________ Inspector Notes from Inspection 9465 3/21/24 WHILE YOU HAVE LOWERED THE REAR DRAINAGE AREA YOU WILL NEED TO LOWER THE AREAS OUTLINED IN WHITE FOR THE DRAINAGE TO SHED AROUND THE CORNERS AND FORWARD TO THE FRONT SWALE. I AM APPROVING THIS FIELD SURVEY AS NOTED TO HELP YOU MOVE FORWARD. PLEASE MAKE THE REQUIRED CORRECTIONS. THERE MAY BE OTHER CORRECTIONS REQUIRED BEFORE ROW FINAL PASSAGE THIS IS NOT INTENDED TO POINT OUT ALL NEEDED CORRECTIONS AS CONDITION MAY CHANGE PRIOR TO YOUR NEXT INSPECTION. _________________________________________________________________________________________________________________________ 3/19/2024 - PREVIOUS INSPECTION NOTES 3/19/24 UPON WALKING PROPERTY DETERMINED THAT THE REAR FALL OFF OF THE PATIO IN THE REAR IS SHOWING 1 TENTH FALL 22.90 TO A 22.80 AND THE REAR PROPERTY LINE IS SHOWING SHOWING 23.30. THIS WILL CAUSE WATER TO FALL BACK ON THE PATIO DURING HARD RAIN. WILL NEED TO CREATE A DEEPER SWALE TO CONTAIN AND SHED WATER AWAY FROM STRUCTURE AND AROUND CORNER. COPC STANDARDS ARE 6 TENTHS FALL FROM STUCTURE TO 10' OUT. Drainage from the structure Section 300, Drawing 300.D, Drainage from the structure is to be a 6 inch (5%) minimum slope for the first 10’ | |||
| BLD - BUILDING FINAL | 03/26/2024 | CANCELLED BY APPLICANT | JWALKER |
| Note: 3/25/2024 - PREVIOUS INSPECTION NOTES 3/25/24- 1. Please raise ODU pad for Proper clearence. FBCM 304.10 Clearances from grade 2. Please seal wall Penetrations at Pump for irrigation, Main water supply entry, irrigation outlet, Power conduit above irrigation pump. FBC R402.4, 3. Please seal ceiling penetration in garage above Pump. FBC R402.4, 4. Please seal all where drip flashing terminates at a wall. R903.2 Flashing 5. Please Identify heater installed for Breaker size. FBC.R. M1303.1 6. Please post Insulation Certificate. FBC R303.1.1.2 7. Garage to house needs a handle installed to seal hole in door. (temporary is fine, new on back order).FBC R402.4, 8. Smoke detector in back bedroom needs relocated to have a min of 4" off the wall. 9. Please repair Master tub valve for direction of flow for Hot water as indicated. FPBC 607.4 Flow of hot water to fixtures.Shower and tub/shower mixing valves 10. Please secure Conduit for Irrigation wire. NEC 352.30 | |||
| BLD - BUILDING FINAL | 03/26/2024 | FINAL APPROVED | JWALKER |
| Note: 3/26/2024 - PREVIOUS INSPECTION NOTES 3/25/2024 - PREVIOUS INSPECTION NOTES 3/25/24- 1. Please raise ODU pad for Proper clearence. FBCM 304.10 Clearances from grade 2. Please seal wall Penetrations at Pump for irrigation, Main water supply entry, irrigation outlet, Power conduit above irrigation pump. FBC R402.4, 3. Please seal ceiling penetration in garage above Pump. FBC R402.4, 4. Please seal all where drip flashing terminates at a wall. R903.2 Flashing 5. Please Identify heater installed for Breaker size. FBC.R. M1303.1 6. Please post Insulation Certificate. FBC R303.1.1.2 7. Garage to house needs a handle installed to seal hole in door. (temporary is fine, new on back order).FBC R402.4, 8. Smoke detector in back bedroom needs relocated to have a min of 4" off the wall. 9. Please repair Master tub valve for direction of flow for Hot water as indicated. FPBC 607.4 Flow of hot water to fixtures.Shower and tub/shower mixing valves 10. Please secure Conduit for Irrigation wire. NEC 352.30 | |||
| BLD - BUILDING FINAL | 03/25/2024 | Disapproved -FEE REQUIRED | JSTEWART |
| Note: 3/25/24- 1. Please raise ODU pad for Proper clearence. FBCM 304.10 Clearances from grade 2. Please seal wall Penetrations at Pump for irrigation, Main water supply entry, irrigation outlet, Power conduit above irrigation pump. FBC R402.4, 3. Please seal ceiling penetration in garage above Pump. FBC R402.4, 4. Please seal all where drip flashing terminates at a wall. R903.2 Flashing 5. Please Identify heater installed for Breaker size. FBC.R. M1303.1 6. Please post Insulation Certificate. FBC R303.1.1.2 7. Garage to house needs a handle installed to seal hole in door. (temporary is fine, new on back order).FBC R402.4, 8. Smoke detector in back bedroom needs relocated to have a min of 4" off the wall. 9. Please repair Master tub valve for direction of flow for Hot water as indicated. FPBC 607.4 Flow of hot water to fixtures.Shower and tub/shower mixing valves 10. Please secure Conduit for Irrigation wire. NEC 352.30 | |||
| ROW - FINAL APRON (AFTER POUR) | 03/25/2024 | APPROVED - AS NOTED | FSLADISH |
| Note: 3/25/24 PAVERS GLUED. NO CRACKS OR BROKEN PIECES AT THIS INSPECTION. CULVERT CLEAR. HOT PATCH COMPLETED. ________________________________________________________________________________________________________________________ Inspector Notes from Inspection 9465 3/21/24 WHILE YOU HAVE LOWERED THE REAR DRAINAGE AREA YOU WILL NEED TO LOWER THE AREAS OUTLINED IN WHITE FOR THE DRAINAGE TO SHED AROUND THE CORNERS AND FORWARD TO THE FRONT SWALE. I AM APPROVING THIS FIELD SURVEY AS NOTED TO HELP YOU MOVE FORWARD. PLEASE MAKE THE REQUIRED CORRECTIONS. THERE MAY BE OTHER CORRECTIONS REQUIRED BEFORE ROW FINAL PASSAGE THIS IS NOT INTENDED TO POINT OUT ALL NEEDED CORRECTIONS AS CONDITION MAY CHANGE PRIOR TO YOUR NEXT INSPECTION. _________________________________________________________________________________________________________________________ 3/19/2024 - PREVIOUS INSPECTION NOTES 3/19/24 UPON WALKING PROPERTY DETERMINED THAT THE REAR FALL OFF OF THE PATIO IN THE REAR IS SHOWING 1 TENTH FALL 22.90 TO A 22.80 AND THE REAR PROPERTY LINE IS SHOWING SHOWING 23.30. THIS WILL CAUSE WATER TO FALL BACK ON THE PATIO DURING HARD RAIN. WILL NEED TO CREATE A DEEPER SWALE TO CONTAIN AND SHED WATER AWAY FROM STRUCTURE AND AROUND CORNER. COPC STANDARDS ARE 6 TENTHS FALL FROM STUCTURE TO 10' OUT. Drainage from the structure Section 300, Drawing 300.D, Drainage from the structure is to be a 6 inch (5%) minimum slope for the first 10’ | |||
| ROW - STORMWATER FINAL | 03/25/2024 | Disapproved - NO FEE | FSLADISH |
| Note: 3/25/24 SPOKE WITH BUILDER THEY WILL NEED TO REPAIR, SLOPE, GRADE AND SOD DISTURBED AREA ON THE LEFT SIDE SWALE PROPERTY LINE. NOT GOING TO FEE YOU TODAY AS I WAS ALREADY HERE FOR THE AFTERPUR INSPECTION.. ___________________________________________________________________________________________________________________________ Inspector Notes from Inspection 9465 3/21/24 WHILE YOU HAVE LOWERED THE REAR DRAINAGE AREA YOU WILL NEED TO LOWER THE AREAS OUTLINED IN WHITE FOR THE DRAINAGE TO SHED AROUND THE CORNERS AND FORWARD TO THE FRONT SWALE. I AM APPROVING THIS FIELD SURVEY AS NOTED TO HELP YOU MOVE FORWARD. PLEASE MAKE THE REQUIRED CORRECTIONS. THERE MAY BE OTHER CORRECTIONS REQUIRED BEFORE ROW FINAL PASSAGE THIS IS NOT INTENDED TO POINT OUT ALL NEEDED CORRECTIONS AS CONDITION MAY CHANGE PRIOR TO YOUR NEXT INSPECTION. _________________________________________________________________________________________________________________________ 3/19/2024 - PREVIOUS INSPECTION NOTES 3/19/24 UPON WALKING PROPERTY DETERMINED THAT THE REAR FALL OFF OF THE PATIO IN THE REAR IS SHOWING 1 TENTH FALL 22.90 TO A 22.80 AND THE REAR PROPERTY LINE IS SHOWING SHOWING 23.30. THIS WILL CAUSE WATER TO FALL BACK ON THE PATIO DURING HARD RAIN. WILL NEED TO CREATE A DEEPER SWALE TO CONTAIN AND SHED WATER AWAY FROM STRUCTURE AND AROUND CORNER. COPC STANDARDS ARE 6 TENTHS FALL FROM STUCTURE TO 10' OUT. Drainage from the structure Section 300, Drawing 300.D, Drainage from the structure is to be a 6 inch (5%) minimum slope for the first 10’ | |||
| U -UTILITY RESIDENTIAL FINAL | 03/25/2024 | FINAL APPROVED | DHANEY |
| ROW FIELD SURVEY /GRADING CERTIFICATION | 03/21/2024 | APPROVED - AS NOTED | FSLADISH |
| Note: 3/21/24 WHILE YOU HAVE LOWERED THE REAR DRAINAGE AREA YOU WILL NEED TO LOWER THE AREAS OUTLINED IN WHITE FOR THE DRAINAGE TO SHED AROUND THE CORNERS AND FORWARD TO THE FRONT SWALE. I AM APPROVING THIS FIELD SURVEY AS NOTED TO HELP YOU MOVE FORWARD. PLEASE MAKE THE REQUIRED CORRECTIONS. THERE MAY BE OTHER CORRECTIONS REQUIRED BEFORE ROW FINAL PASSAGE THIS IS NOT INTENDED TO POINT OUT ALL NEEDED CORRECTIONS AS CONDITION MAY CHANGE PRIOR TO YOUR NEXT INSPECTION. _________________________________________________________________________________________________________________________ 3/19/2024 - PREVIOUS INSPECTION NOTES 3/19/24 UPON WALKING PROPERTY DETERMINED THAT THE REAR FALL OFF OF THE PATIO IN THE REAR IS SHOWING 1 TENTH FALL 22.90 TO A 22.80 AND THE REAR PROPERTY LINE IS SHOWING SHOWING 23.30. THIS WILL CAUSE WATER TO FALL BACK ON THE PATIO DURING HARD RAIN. WILL NEED TO CREATE A DEEPER SWALE TO CONTAIN AND SHED WATER AWAY FROM STRUCTURE AND AROUND CORNER. COPC STANDARDS ARE 6 TENTHS FALL FROM STUCTURE TO 10' OUT. Drainage from the structure Section 300, Drawing 300.D, Drainage from the structure is to be a 6 inch (5%) minimum slope for the first 10’ | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 03/19/2024 | APPROVED | FSLADISH |
| Note: Inspector Notes from Inspection 9270 ** 01/31/24 READY TO SET PAVERS ____________________________________________________________________________________________________________________ Inspector Notes from Inspection 9271 ** 01/24/24 READY TO POUR APRON AND PAVER RESTRAINTS ** At the time of the inspection all minimum city requirements were met. It is the builders responsibility to ensure that nothing changes after this Inspection is approved. This includes but is not limited to, the Culvert Pipe Elevation from the time of the inspection approval to the concrete pour. ** Sec.900.04C Residential driveways shall be constructed using material with a minimum of three thousand pounds (3,000 Ibs.) per square inch with Fiber or wire mesh. | |||
| ROW FIELD SURVEY /GRADING CERTIFICATION | 03/19/2024 | Disapproved - NO FEE | FSLADISH |
| Note: 3/19/24 UPON WALKING PROPERTY DETERMINED THAT THE REAR FALL OFF OF THE PATIO IN THE REAR IS SHOWING 1 TENTH FALL 22.90 TO A 22.80 AND THE REAR PROPERTY LINE IS SHOWING SHOWING 23.30. THIS WILL CAUSE WATER TO FALL BACK ON THE PATIO DURING HARD RAIN. WILL NEED TO CREATE A DEEPER SWALE TO CONTAIN AND SHED WATER AWAY FROM STRUCTURE AND AROUND CORNER. COPC STANDARDS ARE 6 TENTHS FALL FROM STUCTURE TO 10' OUT. Drainage from the structure Section 300, Drawing 300.D, Drainage from the structure is to be a 6 inch (5%) minimum slope for the first 10’ | |||
| ROW- PRE-APRON (PRE-POUR) | 01/31/2024 | APPROVED - AS NOTED | EMADISON |
| Note: ** 01/31/24 READY TO SET PAVERS ____________________________________________________________________________________________________________________ Inspector Notes from Inspection 9271 ** 01/24/24 READY TO POUR APRON AND PAVER RESTRAINTS ** At the time of the inspection all minimum city requirements were met. It is the builders responsibility to ensure that nothing changes after this Inspection is approved. This includes but is not limited to, the Culvert Pipe Elevation from the time of the inspection approval to the concrete pour. ** Sec.900.04C Residential driveways shall be constructed using material with a minimum of three thousand pounds (3,000 Ibs.) per square inch with Fiber or wire mesh. | |||
| ROW- PAVER RESTRAINTS | 01/24/2024 | APPROVED - AS NOTED | EMADISON |
| Note: ** 01/24/24 READY TO POUR APRON AND PAVER RESTRAINTS ** At the time of the inspection all minimum city requirements were met. It is the builders responsibility to ensure that nothing changes after this Inspection is approved. This includes but is not limited to, the Culvert Pipe Elevation from the time of the inspection approval to the concrete pour. ** Sec.900.04C Residential driveways shall be constructed using material with a minimum of three thousand pounds (3,000 Ibs.) per square inch with Fiber or wire mesh. | |||
| ROW- PRE-APRON (PRE-POUR) | 01/24/2024 | PARTIALLY APPROVED | EMADISON |
| Note: ** 01/24/24 READY TO POUR APRON AND PAVER RESTRAINTS ** At the time of the inspection all minimum city requirements were met. It is the builders responsibility to ensure that nothing changes after this Inspection is approved. This includes but is not limited to, the Culvert Pipe Elevation from the time of the inspection approval to the concrete pour. ** Sec.900.04C Residential driveways shall be constructed using material with a minimum of three thousand pounds (3,000 Ibs.) per square inch with Fiber or wire mesh. ** SCHEDULE NEXT PRE-POUR INSPECTION ONCE PAVER BASE HAS BEEN SPREAD AND COMPACTED ** DO NOT SET ANY PAVERS UNTIL THE NEXT PRE-POUR INSPECTION HAS BEEN APPROVED ______________________________________________________________________________________________________________________ 1/23/2024 - PREVIOUS INSPECTION NOTES ** 01/23/24 CANCELLED BY APPLICANT AS COURTESY CHECKED CULVERT RIGHT SIDE TOO LOW NEED TO REVIEW SWALE PLAN DIAGRAM. ** DIG OUT PAVER RESTRAINTS MINIMUM OF 8 INCHES DEEP ** PROVIDE OPTION FOR PAVER DRIVEWAY DETAIL ** REVISE SITE PLAN SHOWING PAVER DRIVEWAY | |||
| ROW- PRE-APRON (PRE-POUR) | 01/23/2024 | CANCELLED BY APPLICANT | EMADISON |
| Note: ** 01/23/24 CANCELLED BY APPLICANT AS COURTESY CHECKED CULVERT RIGHT SIDE TOO LOW NEED TO REVIEW SWALE PLAN DIAGRAM. ** DIG OUT PAVER RESTRAINTS MINIMUM OF 8 INCHES DEEP ** PROVIDE OPTION FOR PAVER DRIVEWAY DETAIL ** REVISE SITE PLAN SHOWING PAVER DRIVEWAY | |||
| ELECTRIC - EARLY POWER | 01/18/2024 | APPROVED | AGAETANO |
| Note: 10/13/2023 - PREVIOUS INSPECTION NOTES | |||
| ELECTRIC TEMP POLE | 10/13/2023 | APPROVED | AGAETANO |
| ELECTRIC - EARLY POWER | 10/13/2023 | CANCELLED BY APPLICANT | AGAETANO |
| INSULATION | 10/03/2023 | APPROVED | AGAETANO |
| U - SEWER TIE IN | 09/27/2023 | PARTIALLY APPROVED | MGIBSON |
| Note: THIS WAS A VIRTUAL INSPECTION | |||
| GRAVITY SEWER TEST | 09/27/2023 | APPROVED - AS NOTED | MGIBSON |
| Note: THIS WAS A VIRTUAL INSPECTION | |||
| ALL ROUGH | 09/20/2023 | APPROVED | AGAETANO |
| Note: 8/9/2023 - PREVIOUS INSPECTION NOTES 08-09-2023 Windows and doors approved only. Please cover the entry door openings prior to insulation inspection. | |||
| LATH/BRICK/ WATER BARRIER | 09/06/2023 | APPROVED | AGAETANO |
| ROW - DRAINAGE | 08/14/2023 | APPROVED - AS NOTED | EMADISON |
| Note: ** 08/14/23 DRAINAGE ISSUES AS NOTED IN PREVIOUS INSPECTION CORRECTED ** BUILDER STILL NEEDS TO PICK UP TRASH FROM SITE __________________________________________________________________________________________________________________________ 8/9/2023 - PREVIOUS INSPECTION NOTES ** 08/09/23 BUILDER NEEDS TO OPEN TEMPORARY CULVERT AS IT IS BURRIED AND CLOGGED PREVENTING THE FLOW OF STORMWATER ** REMOVE CONSTRUCTION DEBRIS FROM ROAD SIDE SWALE ** REMOVE PORT-A-JOHN FROM ROADSIDE SWALE AND PUT ONTO JOB SITE ** BUILDER ALSO NEEDS TO PICK UP THE SCATTERED TRASH FROM HIS SITE ** FOLLOW UP INSPECTION ON 08/14/23 _______________________________________________________________________________________________________________________ Please check that swale is clear and functioning and proper erosion control is in place-JM | |||
| ALL ROUGH | 08/09/2023 | PARTIALLY APPROVED | AGAETANO |
| Note: 08-09-2023 Windows and doors approved only. Please cover the entry door openings prior to insulation inspection. | |||
| ROW - DRAINAGE | 08/09/2023 | Disapproved -FEE REQUIRED | EMADISON |
| Note: ** 08/09/23 BUILDER NEEDS TO OPEN TEMPORARY CULVERT AS IT IS BURRIED AND CLOGGED PREVENTING THE FLOW OF STORMWATER ** REMOVE CONSTRUCTION DEBRIS FROM ROAD SIDE SWALE ** REMOVE PORT-A-JOHN FROM ROADSIDE SWALE AND PUT ONTO JOB SITE ** BUILDER ALSO NEEDS TO PICK UP THE SCATTERED TRASH FROM HIS SITE ** FOLLOW UP INSPECTION ON 08/14/23 _______________________________________________________________________________________________________________________ Please check that swale is clear and functioning and proper erosion control is in place-JM | |||
| WALL SHEATHING | 08/08/2023 | APPROVED | AGAETANO |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 07/31/2023 | APPROVED | AGAETANO |
| Note: 6/20/2023 - PREVIOUS INSPECTION NOTES 6/9/2023 - PREVIOUS INSPECTION NOTES 6/6/2023 - PREVIOUS INSPECTION NOTES 06-06-2023 Drawings are a matted mess. Please provide a full set of approved, full size, readable dreings for all inspections. Please organize documents in the job box. 06-09-2023 1. Nook windows do not have headers. Please provide details for headers or engineering as installed. 2. Piggyback trusses not per plans. 3. Truss layout not on site. Inspection stopped. 06-20-2023 1. Sheet 4/5 Interior bearig wall indicates 1/2" rods both sides of door. Only one installed. Please install as per plans or provide engineering letter ot building department and have o site. 2. A11 & A12 missing members. 3. Trusses D04 through D07 anchors not specified on drawings. 4. A01 through A08 anchors not installed as per truss connector schedule. 5. Engineering letter for fixed glass framing and front entry details needed prior to next inspection. | |||
| ROOF VALLEY & METAL | 07/31/2023 | APPROVED | AGAETANO |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 06/20/2023 | Disapproved - NO FEE | AGAETANO |
| Note: 6/9/2023 - PREVIOUS INSPECTION NOTES 6/6/2023 - PREVIOUS INSPECTION NOTES 06-06-2023 Drawings are a matted mess. Please provide a full set of approved, full size, readable dreings for all inspections. Please organize documents in the job box. 06-09-2023 1. Nook windows do not have headers. Please provide details for headers or engineering as installed. 2. Piggyback trusses not per plans. 3. Truss layout not on site. Inspection stopped. 06-20-2023 1. Sheet 4/5 Interior bearig wall indicates 1/2" rods both sides of door. Only one installed. Please install as per plans or provide engineering letter ot building department and have o site. 2. A11 & A12 missing members. 3. Trusses D04 through D07 anchors not specified on drawings. 4. A01 through A08 anchors not installed as per truss connector schedule. 5. Engineering letter for fixed glass framing and front entry details needed prior to next inspection. | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 06/09/2023 | Disapproved - NO FEE | AGAETANO |
| Note: 6/6/2023 - PREVIOUS INSPECTION NOTES 06-06-2023 Drawings are a matted mess. Please provide a full set of approved, full size, readable dreings for all inspections. Please organize documents in the job box. 06-09-2023 1. Nook windows do not have headers. Please provide details for headers or engineering as installed. 2. Piggyback trusses not per plans. 3. Truss layout not on site. 4. Please expose front entry for small window attachment at CMU. Provide details. Inspection stopped. | |||
| ROOF SHEATHING | 06/06/2023 | APPROVED | AGAETANO |
| Note: 06-06-2023 Roof sheathing only is approved. | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 06/06/2023 | Disapproved - NO FEE | AGAETANO |
| Note: 06-06-2023 Drawings are a matted mess. Please provide a full set of approved, full size, readable dreings for all inspections. Please organize documents in the job box. | |||
| TIE BEAM / LINTEL | 05/10/2023 | APPROVED | AGAETANO |
| FOUND SURVEY APPROVED (OFFICE) | 03/08/2023 | APPROVED | TBAKER |
| MONOLITHIC SLAB | 02/27/2023 | APPROVED | FWILLIS |
| Note: 2/24/2023 - PREVIOUS INSPECTION NOTES 02-24-2023 1. R319.1 Address identification. Buildings shall be provided with approved address identification. The address identification shall be legible and placed in a position that is visiblen from the street or road fronting the property. Address identification characters shall contrast with their background. Address numbers shall be Arabic numbers or alphabetical letters. Numbers shall not be spelled out. Each character shall be not less than 4 inches (102 mm) in height with a stroke width of not less than 0.5 inch (12.7 mm). Where required by the fire code official, address identification shall be provided in additional approved locations to facilitate emergency response. Where access is by means of a private road and the building address cannot be viewed from the public way, a monument, pole or other sign or means shall be used to identify the structure. Address identification shall be maintained. 2. Root in slab. Please remove. Noted on drawings. 3. Please tamp area noted on drawings. Inspection stopped. Not ready for inspection. | |||
| MONOLITHIC SLAB | 02/24/2023 | Disapproved -FEE REQUIRED | AGAETANO |
| Note: 02-24-2023 1. R319.1 Address identification. Buildings shall be provided with approved address identification. The address identification shall be legible and placed in a position that is visiblen from the street or road fronting the property. Address identification characters shall contrast with their background. Address numbers shall be Arabic numbers or alphabetical letters. Numbers shall not be spelled out. Each character shall be not less than 4 inches (102 mm) in height with a stroke width of not less than 0.5 inch (12.7 mm). Where required by the fire code official, address identification shall be provided in additional approved locations to facilitate emergency response. Where access is by means of a private road and the building address cannot be viewed from the public way, a monument, pole or other sign or means shall be used to identify the structure. Address identification shall be maintained. 2. Root in slab. Please remove. Noted on drawings. 3. Please tamp area noted on drawings. Inspection stopped. Not ready for inspection. | |||
| PLUMBING 1ST ROUGH UNDERGROUND | 02/21/2023 | APPROVED | MGIBSON |
| WATER METER INSTALLATION REQUEST | 02/16/2023 | APPROVED | TSCHWEERS |
Review History
| Department | Status | Date In | Date Out |
| BADMIN | INFORMATION | 03/12/2024 | 03/12/2024 |
| Note: Marked INFORMATION By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM other inspections needed | |||
| ENGIN1 | COMPLETE | 01/23/2024 | 01/24/2024 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 12/27/2023 | 12/28/2023 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 12/27/2023 | 01/04/2024 |
| Note: Released By: JEFF CREWS - - JCREWS@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 12/27/2023 | 12/27/2023 |
| Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 07/21/2023 | 07/24/2023 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 07/12/2023 | 07/17/2023 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| MECH | HOLD | 07/12/2023 | 07/13/2023 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM 1. Energy Calcs need to be signed by the owner/ owner agent below the preparer per R103.1.1.2 FBC Energy Conservation 2020 7Th edition 2. Duct layout needs to be signed by the AC contractor per 107.1 FBC Residential 2020 7th Edition Upload all documents as one file. named Energy Calcs | |||
| BLD | COMPLETE | 05/03/2023 | 05/03/2023 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 03/07/2023 | 03/08/2023 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 03/07/2023 | 03/07/2023 |
| Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 12/22/2022 | 12/22/2022 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| ELEC | COMPLETE | 12/22/2022 | 12/22/2022 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 12/22/2022 | 01/04/2023 |
| Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM | |||
| ELEC | COMPLETE | 12/21/2022 | 12/21/2022 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| MECH | HOLD | 12/21/2022 | 12/21/2022 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Duct layout needs to be signed by the AC contractor | |||
| ZON | COMPLETE | 12/21/2022 | 12/21/2022 |
| Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 12/21/2022 | 12/21/2022 |
| Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 12/21/2022 | 12/21/2022 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| BLD | HOLD | 12/14/2022 | 12/16/2022 |
| Note: Held By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM All comments below per the 2020 Florida Building Code REVIEW COMMENTS: 1. Provide product approval numbers for wood connectors and wood anchors. 2. Provide product approval number for rear glass doors | |||
| CUSVC | COMPLETE | 12/14/2022 | 12/19/2022 |
| Note: Released By: LISA ASBILL - - lasbill@palmcoastgov.com | |||
| ELEC | HOLD | 12/14/2022 | 12/14/2022 |
| Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM Submit electric load calcs | |||
| ENGIN1 | COMPLETE | 12/14/2022 | 12/14/2022 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| LOCATE | COMPLETE | 12/14/2022 | 12/15/2022 |
| Note: Released By: TONI CHURCHILL - - | |||
| MECH | HOLD | 12/14/2022 | 12/14/2022 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM 1. Provide return air for library on duct layout. 2. Duct layout needs to be signed by the AC contractor | |||
| SW1 | COMPLETE | 12/14/2022 | 12/19/2022 |
| Note: Released By: EDWARD MADISON - - EMADISON@PALMCOASTGOV.COM | |||
| ZON | HOLD | 12/14/2022 | 12/15/2022 |
| Note: Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM Plans and landscape plan show a door pad on the left side. Site plan must show this and it must meet a 5ft setback so it does not encroach in the 5ft utility easement | |||
| SWALE | COMPLETE | 12/14/2022 | 03/30/2023 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION RESIDENTIAL | ¤40.00 | 03/27/2024 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 03/17/2024 |
| SW ENG - INSPECTION 20 | ¤20.00 | 03/17/2024 |
| SW ENG - INSPECTION 20 | ¤20.00 | 03/17/2024 |
| PLAN REVIEW - REVISION | ¤32.50 | 03/17/2024 |
| PLAN REVIEW - REVISION | ¤32.50 | 03/17/2024 |
| WATER- TURN ON | ¤25.00 | 01/09/2023 |
| ADJUSTMENT 50% | (¤623.93) | 01/09/2023 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 01/09/2023 |
| INSPECTION - RESIDENTIAL | ¤948.75 | 01/09/2023 |
| PLAN REVIEW - RESIDENTIAL | ¤269.10 | 01/09/2023 |
| SW ENG INSPECTION 80 | ¤80.00 | 01/09/2023 |
| SW ENG PRE APRON | ¤30.00 | 01/09/2023 |
| SW ENG - REVIEW 20 | ¤20.00 | 01/09/2023 |
| SW ENG RES REVIEW 200 | ¤200.00 | 01/09/2023 |
| TRANS IMPACT FEE ADMIN | ¤52.92 | 01/09/2023 |
| TRANS IMPACT FEE ADMIN | (¤52.92) | 01/09/2023 |
| SEWER CREDIT | (¤2,465.75) | 01/09/2023 |
| SEWER INSPECTION | ¤25.00 | 01/09/2023 |
| SEWER CAPITAL FACILITY | ¤5,344.82 | 01/09/2023 |
| WATER CAPITAL FACILITY FEE | ¤3,923.88 | 01/09/2023 |
| SITE PLAN 30 | ¤30.00 | 01/09/2023 |
| CONNECTION FEES | ¤1,166.26 | 01/09/2023 |
| FIRE IMPACT FEE ADMIN | ¤12.62 | 01/09/2023 |
| FIRE IMPACT FEE ADMIN | (¤12.62) | 01/09/2023 |
| FC IMPACT FEE EMS | ¤62.00 | 01/09/2023 |
| IMPACT FEE FIRE | ¤420.52 | 01/09/2023 |
| FC IMPACT FEE LAW ENFORCEMENT | ¤218.00 | 01/09/2023 |
| FC IMPACT FEE LIBRARY | ¤268.00 | 01/09/2023 |
| IMPACT FEE PARKS | ¤1,769.15 | 01/09/2023 |
| IMPACT FEE SCHOOL | ¤5,450.00 | 01/09/2023 |
| IMPACT FEE TRANSPORTATION | ¤1,764.00 | 01/09/2023 |
| WATER -IRRIGATION INSPECTION | ¤25.00 | 01/09/2023 |
| PARKS IMPACT FEE ADMIN | ¤53.07 | 01/09/2023 |
| PARKS IMPACT FEE ADMIN | (¤53.07) | 01/09/2023 |
| SURCHARGE FS 533.721 | ¤3.95 | 01/09/2023 |
| SURCHARGE - FS 468.631 | ¤5.92 | 01/09/2023 |
| SW ENG - FOUNDATION SURVEY | ¤20.00 | 01/09/2023 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤19,194.67 |