Permit #2022120992
Permit Details
Status: COED
| Parcel Id: 07-11-31-7035-01110-0060 |
| CONDITIONED SPACE: 1906 sqft |
| GARAGE: 400 sqft |
| OPENED PORCH (WITH ROOF) : 20 sqft |
| Total Square Footage: 2326 sqft |
| Block: 01110 |
| Subdivision: 2172 - SECTION 35-BELLE TERRE |
| Job Phone: 470-817-1259 |
| Location Address: 52 BISCAYNE DR |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 01/23/2023 |
| NOC: RECORDED |
| Applicant name: WADE GILMER JURNEY JR |
| Owner: NATIONAL HOME CORPORATION |
|
Address 1080 HOLCOMB BRIDGE ROAD 100-330 ROSWELL, GA 30076 |
| Lot: 0060 |
| Contracted Stated Job Value: ¤239,639.00 |
| Job Description: Single Family Residence |
| Type: CN |
Contractor
NATIONAL HOME CORPORATION
| Status | Location Address | Mailing Address | State License Number | Phone |
| INACTIVE |
1080 HOLCOMB BRIDGE ROAD , |
BLDG 100 - 330 ROSWELL , GA 30076 |
CBC1257700 (Exp: 08/31/2026) | 471-817-1259 |
Sub Contractors
RANDALL SCOTT ROSENFELD
| Status | Location Address | State License Number | Phone |
| ACTIVE |
234 N WHITNEY ST PALM COAST, FL 32084 |
CAC1816641 (Exp: 08/31/2026) | 904-599-0082 |
DUSTIN L ESTEP
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
2041 N HIAWASSEE RD APOPKA, FL 32703 |
CCC1330971 (Exp: 08/31/2026) | 407-702-0206 | 352-988-6629 |
JASON PATRICK RIBOCK
| Status | Location Address | State License Number | Phone |
| INACTIVE |
620 E PINE ST , 0 |
ES12001313 (Exp: 08/31/2026) | 407-625-0257 |
PAUL ERIC FORSTER
| Status | Location Address | State License Number | Phone |
| ACTIVE |
6114 GOODMAN RD JACKSONVILLE, FL 32244 |
CFC1429261 (Exp: 08/31/2026) | 904-647-1820 |
Inspection History
| Type | Request Date | Result | Inspector |
| BLD - BUILDING FINAL | 01/26/2024 | FINAL APPROVED | JSTEWART |
| Note: 1/25/2024 - PREVIOUS INSPECTION NOTES 1/25/24- 1. Please extend Hot water Auxillary pan discharge. 504.7.2 Pan drain termination....terminate not less than 6 inches (152 mm) and not more than 24 inches (610 mm) above the adjacent ground surface. 2. No Hot water. 3. Please seal off interior of Dryer duct. (Unless Dryer is installed.) Inspector Notes from Inspection 2490 8/31/23- Energy calcs onsite Match whats installed for returns, but revision needs to be submitted and aproved by the city. please obtain revision. before final. 8/29/2023 - PREVIOUS INSPECTION NOTES 8/29/23- Previous note not rectified....2nd floor header returns installed are smaller size then on energy calcs. (10x6 vs 24x4). Please obtain revision of what is installed or install per plan. will check at insulation. Double wall 2nd floor needs to be fire stopped at joining seam. please seal floor penetration at 2nd floor condensation pipe. No Address displayed....R319.1 Address identification. Buildings shall be provided with approved address identification. The address identification shall be legible and placed in a position that is visible from the street or road fronting the property Inspector Notes from Inspection 2420 8/10/23- 2nd floor header returns installed are smaller size then on energy calcs. (10x6 vs 24x4). Please obtain revision of what is installed or install per plan. will check at insulation. 7/14/2023 - PREVIOUS INSPECTION NOTES 7/14/23- No Permit, energy calcs, product aproval onsite. Permit must be permanetly onsite. Drywall drop leaning on walls unable to see. Please move drywall from breaker panel unable to verify connection and ground. Stopped inspection. | |||
| U-CROSS CONNECTION | 01/25/2024 | APPROVED | DHANEY |
| BLD - BUILDING FINAL | 01/25/2024 | Disapproved - NO FEE | JSTEWART |
| Note: 1/25/24- 1. Please extend Hot water Auxillary pan discharge. 504.7.2 Pan drain termination....terminate not less than 6 inches (152 mm) and not more than 24 inches (610 mm) above the adjacent ground surface. 2. No Hot water. 3. Please seal off interior of Dryer duct. (Unless Dryer is installed.) Inspector Notes from Inspection 2490 8/31/23- Energy calcs onsite Match whats installed for returns, but revision needs to be submitted and aproved by the city. please obtain revision. before final. 8/29/2023 - PREVIOUS INSPECTION NOTES 8/29/23- Previous note not rectified....2nd floor header returns installed are smaller size then on energy calcs. (10x6 vs 24x4). Please obtain revision of what is installed or install per plan. will check at insulation. Double wall 2nd floor needs to be fire stopped at joining seam. please seal floor penetration at 2nd floor condensation pipe. No Address displayed....R319.1 Address identification. Buildings shall be provided with approved address identification. The address identification shall be legible and placed in a position that is visible from the street or road fronting the property Inspector Notes from Inspection 2420 8/10/23- 2nd floor header returns installed are smaller size then on energy calcs. (10x6 vs 24x4). Please obtain revision of what is installed or install per plan. will check at insulation. 7/14/2023 - PREVIOUS INSPECTION NOTES 7/14/23- No Permit, energy calcs, product aproval onsite. Permit must be permanetly onsite. Drywall drop leaning on walls unable to see. Please move drywall from breaker panel unable to verify connection and ground. Stopped inspection. | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 01/24/2024 | APPROVED | TPOLACEK |
| Note: 01/24/24 UPON WALKING PROPERTY DRAINAGE WILL WORK AS INDICATED ON FINAL SURVEY. AT THE TIME FROM THE TIME OF THE INSPECTION OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. Inspector Notes from Inspection 9270 ** 12/14/23 READY TO POUR ** At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved. This includes but is not limited to, the Culvert Pipe Elevation from the time of the inspection approval to the concrete pour. ** Sec.900.04C Residential driveways shall be constructed using material with a minimum of three thousand pounds (3,000 Ibs.) per square inch with Fiber or wire mesh. ___________________________________________________________________________________________________________________ 12/12/2023 - PREVIOUS INSPECTION NOTES ** 12/12/23 BUILDER NEEDS TO REVIEW ALL NOTES LEFT BY THE INSPECTOR CENTER OF CULVERT NEEDS TO BE 8 FEET FROM EDGE OF ROAD. RECHECK YOUR EDGE OF ROAD FORM BOARDS. ** CULVERT FOOTS AT THE MITERED ENDS NEED TO BE 6INCHES X 6INCHES X 18INCHES ** CULVERT NEEDS TO BE BURIED HALFWAY UP YOURS HAS NO MATERIAL AROUND IT CULVERT IS JUST SITTING ON GROUND WITH NO MATERIAL HOLDING IT IN PLACE NEED TO HAVE A SLOPE AS SHOWN IN DIAGRAM 300.E ON EITHER SIDE OF CULVERT ** SEE PHOTOGRAPHS OF THE CULVERT DETAIL NOTE THE CIRCLED AREAS FOR YOUR CORRECTION ON THE CULVERT DETAIL PLAN LEFT IN THE PICTURE AREA OF THIS INSPECTION ______________________________________________________________________________________________________________________ 12/11/2023 - PREVIOUS INSPECTION NOTES 12/11/23 ** AT TIME OF INSPECTION PIPE IS GOOD. RIGHT SIDE APRON END NEEDS TO BE BROUGHT BACK BEHIND EDGE OF ROAD ( SEE PHOTO) ALSO BOTH MITER END FOOTERS NEED TO BE DUG OUT TO A MINUMUM OF 6" DEEP.A minimum footer of six (6) inches by six (6) is required under each culvert end, not to extend past the end of the MES. ____________________________________________________________________________ 11/17/2023 - PREVIOUS INSPECTION NOTES ** 11/17/23 SITE IS FLOODED NOT READY FOR INSPECTION ** SEE ATTACHED PHOTOS _________________________________________________________________________________________________________________________ 11/15/2023 - PREVIOUS INSPECTION NOTES ** 11/15/23 ADDRESS MUST BE POSTED AND PLAINLY VISIBLE TO INSPECTORS. IF ADDRESS IS NOT PLAINLY VISIBLE, INSPECTORS WILL NOT PERFORM INSPECTIONS AND A REINSPECTION FEE WILL BE ISSUED. Florida Building Code-Building Section 501.2 01/24/24 UPON WALKING PROPERTY DRAINAGE WILL WORK AS INDICATED ON FINAL SURVEY. AT THE TIME FROM THE TIME OF THE INSPECTION OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. Inspector Notes from Inspection 9270 ** 12/14/23 READY TO POUR ** At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved. This includes but is not limited to, the Culvert Pipe Elevation from the time of the inspection approval to the concrete pour. ** Sec.900.04C Residential driveways shall be constructed using material with a minimum of three thousand pounds (3,000 Ibs.) per square inch with Fiber or wire mesh. ___________________________________________________________________________________________________________________ 12/12/2023 - PREVIOUS INSPECTION NOTES ** 12/12/23 BUILDER NEEDS TO REVIEW ALL NOTES LEFT BY THE INSPECTOR CENTER OF CULVERT NEEDS TO BE 8 FEET FROM EDGE OF ROAD. RECHECK YOUR EDGE OF ROAD FORM BOARDS. ** CULVERT FOOTS AT THE MITERED ENDS NEED TO BE 6INCHES X 6INCHES X 18INCHES ** CULVERT NEEDS TO BE BURIED HALFWAY UP YOURS HAS NO MATERIAL AROUND IT CULVERT IS JUST SITTING ON GROUND WITH NO MATERIAL HOLDING IT IN PLACE NEED TO HAVE A SLOPE AS SHOWN IN DIAGRAM 300.E ON EITHER SIDE OF CULVERT ** SEE PHOTOGRAPHS OF THE CULVERT DETAIL NOTE THE CIRCLED AREAS FOR YOUR CORRECTION ON THE CULVERT DETAIL PLAN LEFT IN THE PICTURE AREA OF THIS INSPECTION ______________________________________________________________________________________________________________________ 12/11/2023 - PREVIOUS INSPECTION NOTES 12/11/23 ** AT TIME OF INSPECTION PIPE IS GOOD. RIGHT SIDE APRON END NEEDS TO BE BROUGHT BACK BEHIND EDGE OF ROAD ( SEE PHOTO) ALSO BOTH MITER END FOOTERS NEED TO BE DUG OUT TO A MINUMUM OF 6" DEEP.A minimum footer of six (6) inches by six (6) is required under each culvert end, not to extend past the end of the MES. ____________________________________________________________________________ 11/17/2023 - PREVIOUS INSPECTION NOTES ** 11/17/23 SITE IS FLOODED NOT READY FOR INSPECTION ** SEE ATTACHED PHOTOS _________________________________________________________________________________________________________________________ 11/15/2023 - PREVIOUS INSPECTION NOTES ** 11/15/23 ADDRESS MUST BE POSTED AND PLAINLY VISIBLE TO INSPECTORS. IF ADDRESS IS NOT PLAINLY VISIBLE, INSPECTORS WILL NOT PERFORM INSPECTIONS AND A REINSPECTION FEE WILL BE ISSUED. Florida Building Code-Building Section 501.2 | |||
| ROW FIELD SURVEY /GRADING CERTIFICATION | 01/24/2024 | APPROVED | TPOLACEK |
| Note: 01/24/24 AT THE TIME FROM THE TIME OF THE INSPECTION OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. | |||
| ROW - STORMWATER FINAL | 01/24/2024 | APPROVED | TPOLACEK |
| Note: AT THE TIME FROM THE TIME OF THE INSPECTION OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED | |||
| U -UTILITY RESIDENTIAL FINAL | 01/24/2024 | CANCELLED BY INSPECTOR | TPOLACEK |
| Note: SORRY LARRY CREATED BY ACCIDENT | |||
| ROW - FINAL APRON (AFTER POUR) | 01/24/2024 | APPROVED | TPOLACEK |
| Note: 01/24/24 PIPE IS GOOD, CUTS ARE MADE, CULVERT CLEAR, HOT PATCH COMPLETE. AT THE TIME FROM THE TIME OF THE INSPECTION OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. | |||
| ROW- PRE-APRON (PRE-POUR) | 12/14/2023 | APPROVED - AS NOTED | EMADISON |
| Note: ** 12/14/23 READY TO POUR ** At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved. This includes but is not limited to, the Culvert Pipe Elevation from the time of the inspection approval to the concrete pour. ** Sec.900.04C Residential driveways shall be constructed using material with a minimum of three thousand pounds (3,000 Ibs.) per square inch with Fiber or wire mesh. ___________________________________________________________________________________________________________________ 12/12/2023 - PREVIOUS INSPECTION NOTES ** 12/12/23 BUILDER NEEDS TO REVIEW ALL NOTES LEFT BY THE INSPECTOR CENTER OF CULVERT NEEDS TO BE 8 FEET FROM EDGE OF ROAD. RECHECK YOUR EDGE OF ROAD FORM BOARDS. ** CULVERT FOOTS AT THE MITERED ENDS NEED TO BE 6INCHES X 6INCHES X 18INCHES ** CULVERT NEEDS TO BE BURIED HALFWAY UP YOURS HAS NO MATERIAL AROUND IT CULVERT IS JUST SITTING ON GROUND WITH NO MATERIAL HOLDING IT IN PLACE NEED TO HAVE A SLOPE AS SHOWN IN DIAGRAM 300.E ON EITHER SIDE OF CULVERT ** SEE PHOTOGRAPHS OF THE CULVERT DETAIL NOTE THE CIRCLED AREAS FOR YOUR CORRECTION ON THE CULVERT DETAIL PLAN LEFT IN THE PICTURE AREA OF THIS INSPECTION ______________________________________________________________________________________________________________________ 12/11/2023 - PREVIOUS INSPECTION NOTES 12/11/23 ** AT TIME OF INSPECTION PIPE IS GOOD. RIGHT SIDE APRON END NEEDS TO BE BROUGHT BACK BEHIND EDGE OF ROAD ( SEE PHOTO) ALSO BOTH MITER END FOOTERS NEED TO BE DUG OUT TO A MINUMUM OF 6" DEEP.A minimum footer of six (6) inches by six (6) is required under each culvert end, not to extend past the end of the MES. ____________________________________________________________________________ 11/17/2023 - PREVIOUS INSPECTION NOTES ** 11/17/23 SITE IS FLOODED NOT READY FOR INSPECTION ** SEE ATTACHED PHOTOS _________________________________________________________________________________________________________________________ 11/15/2023 - PREVIOUS INSPECTION NOTES ** 11/15/23 ADDRESS MUST BE POSTED AND PLAINLY VISIBLE TO INSPECTORS. IF ADDRESS IS NOT PLAINLY VISIBLE, INSPECTORS WILL NOT PERFORM INSPECTIONS AND A REINSPECTION FEE WILL BE ISSUED. Florida Building Code-Building Section 501.2 | |||
| ROW- PRE-APRON (PRE-POUR) | 12/12/2023 | Disapproved -FEE REQUIRED | EMADISON |
| Note: ** 12/12/23 BUILDER NEEDS TO REVIEW ALL NOTES LEFT BY THE INSPECTOR CENTER OF CULVERT NEEDS TO BE 8 FEET FROM EDGE OF ROAD. RECHECK YOUR EDGE OF ROAD FORM BOARDS. ** CULVERT FOOTS AT THE MITERED ENDS NEED TO BE 6INCHES X 6INCHES X 18INCHES ** CULVERT NEEDS TO BE BURIED HALFWAY UP YOURS HAS NO MATERIAL AROUND IT CULVERT IS JUST SITTING ON GROUND WITH NO MATERIAL HOLDING IT IN PLACE NEED TO HAVE A SLOPE AS SHOWN IN DIAGRAM 300.E ON EITHER SIDE OF CULVERT ** SEE PHOTOGRAPHS OF THE CULVERT DETAIL NOTE THE CIRCLED AREAS FOR YOUR CORRECTION ON THE CULVERT DETAIL PLAN LEFT IN THE PICTURE AREA OF THIS INSPECTION ______________________________________________________________________________________________________________________ 12/11/2023 - PREVIOUS INSPECTION NOTES 12/11/23 ** AT TIME OF INSPECTION PIPE IS GOOD. RIGHT SIDE APRON END NEEDS TO BE BROUGHT BACK BEHIND EDGE OF ROAD ( SEE PHOTO) ALSO BOTH MITER END FOOTERS NEED TO BE DUG OUT TO A MINUMUM OF 6" DEEP.A minimum footer of six (6) inches by six (6) is required under each culvert end, not to extend past the end of the MES. ____________________________________________________________________________ 11/17/2023 - PREVIOUS INSPECTION NOTES ** 11/17/23 SITE IS FLOODED NOT READY FOR INSPECTION ** SEE ATTACHED PHOTOS _________________________________________________________________________________________________________________________ 11/15/2023 - PREVIOUS INSPECTION NOTES ** 11/15/23 ADDRESS MUST BE POSTED AND PLAINLY VISIBLE TO INSPECTORS. IF ADDRESS IS NOT PLAINLY VISIBLE, INSPECTORS WILL NOT PERFORM INSPECTIONS AND A REINSPECTION FEE WILL BE ISSUED. Florida Building Code-Building Section 501.2 | |||
| ROW- PRE-APRON (PRE-POUR) | 12/11/2023 | Disapproved -FEE REQUIRED | TPOLACEK |
| Note: 12/11/23 ** AT TIME OF INSPECTION PIPE IS GOOD. RIGHT SIDE APRON END NEEDS TO BE BROUGHT BACK BEHIND EDGE OF ROAD ( SEE PHOTO) ALSO BOTH MITER END FOOTERS NEED TO BE DUG OUT TO A MINUMUM OF 6" DEEP.A minimum footer of six (6) inches by six (6) is required under each culvert end, not to extend past the end of the MES. ____________________________________________________________________________ 11/17/2023 - PREVIOUS INSPECTION NOTES ** 11/17/23 SITE IS FLOODED NOT READY FOR INSPECTION ** SEE ATTACHED PHOTOS _________________________________________________________________________________________________________________________ 11/15/2023 - PREVIOUS INSPECTION NOTES ** 11/15/23 ADDRESS MUST BE POSTED AND PLAINLY VISIBLE TO INSPECTORS. IF ADDRESS IS NOT PLAINLY VISIBLE, INSPECTORS WILL NOT PERFORM INSPECTIONS AND A REINSPECTION FEE WILL BE ISSUED. Florida Building Code-Building Section 501.2 | |||
| ROW- PRE-APRON (PRE-POUR) | 11/17/2023 | Disapproved -FEE REQUIRED | EMADISON |
| Note: ** 11/17/23 SITE IS FLOODED NOT READY FOR INSPECTION ** SEE ATTACHED PHOTOS _________________________________________________________________________________________________________________________ 11/15/2023 - PREVIOUS INSPECTION NOTES ** 11/15/23 ADDRESS MUST BE POSTED AND PLAINLY VISIBLE TO INSPECTORS. IF ADDRESS IS NOT PLAINLY VISIBLE, INSPECTORS WILL NOT PERFORM INSPECTIONS AND A REINSPECTION FEE WILL BE ISSUED. Florida Building Code-Building Section 501.2 | |||
| ELECTRIC - EARLY POWER | 11/17/2023 | APPROVED - AS NOTED | JSTEWART |
| Note: 11/17/23- Authorize release of email to FPL @ 9:21a | |||
| ROW- PRE-APRON (PRE-POUR) | 11/15/2023 | Disapproved - NO FEE | EMADISON |
| Note: ** 11/15/23 ADDRESS MUST BE POSTED AND PLAINLY VISIBLE TO INSPECTORS. IF ADDRESS IS NOT PLAINLY VISIBLE, INSPECTORS WILL NOT PERFORM INSPECTIONS AND A REINSPECTION FEE WILL BE ISSUED. Florida Building Code-Building Section 501.2 | |||
| GRAVITY SEWER TEST | 10/13/2023 | APPROVED - AS NOTED | MGIBSON |
| Note: THIS WAS A VIRTUAL INSPECTION | |||
| U - SEWER TIE IN | 10/13/2023 | APPROVED - AS NOTED | MGIBSON |
| Note: THIS WAS A VIRTUAL INSPECTION | |||
| PEP TANK INSTALLATION REQUEST | 09/06/2023 | APPROVED | CBOWERMASTER |
| INSULATION | 08/31/2023 | APPROVED - AS NOTED | JSTEWART |
| Note: 8/31/23- Energy calcs onsite Match whats installed for returns, but revision needs to be submitted and aproved by the city. please obtain revision. before final. 8/29/2023 - PREVIOUS INSPECTION NOTES 8/29/23- Previous note not rectified....2nd floor header returns installed are smaller size then on energy calcs. (10x6 vs 24x4). Please obtain revision of what is installed or install per plan. will check at insulation. Double wall 2nd floor needs to be fire stopped at joining seam. please seal floor penetration at 2nd floor condensation pipe. No Address displayed....R319.1 Address identification. Buildings shall be provided with approved address identification. The address identification shall be legible and placed in a position that is visible from the street or road fronting the property Inspector Notes from Inspection 2420 8/10/23- 2nd floor header returns installed are smaller size then on energy calcs. (10x6 vs 24x4). Please obtain revision of what is installed or install per plan. will check at insulation. 7/14/2023 - PREVIOUS INSPECTION NOTES 7/14/23- No Permit, energy calcs, product aproval onsite. Permit must be permanetly onsite. Drywall drop leaning on walls unable to see. Please move drywall from breaker panel unable to verify connection and ground. Stopped inspection. | |||
| INSULATION | 08/29/2023 | Disapproved -FEE REQUIRED | JSTEWART |
| Note: 8/29/23- Previous note not rectified....2nd floor header returns installed are smaller size then on energy calcs. (10x6 vs 24x4). Please obtain revision of what is installed or install per plan. will check at insulation. Double wall 2nd floor needs to be fire stopped at joining seam. please seal floor penetration at 2nd floor condensation pipe. No Address displayed....R319.1 Address identification. Buildings shall be provided with approved address identification. The address identification shall be legible and placed in a position that is visible from the street or road fronting the property Inspector Notes from Inspection 2420 8/10/23- 2nd floor header returns installed are smaller size then on energy calcs. (10x6 vs 24x4). Please obtain revision of what is installed or install per plan. will check at insulation. 7/14/2023 - PREVIOUS INSPECTION NOTES 7/14/23- No Permit, energy calcs, product aproval onsite. Permit must be permanetly onsite. Drywall drop leaning on walls unable to see. Please move drywall from breaker panel unable to verify connection and ground. Stopped inspection. | |||
| ALL ROUGH | 08/10/2023 | APPROVED - AS NOTED | JSTEWART |
| Note: 8/10/23- 2nd floor header returns installed are smaller size then on energy calcs. (10x6 vs 24x4). Please obtain revision of what is installed or install per plan. will check at insulation. 7/14/2023 - PREVIOUS INSPECTION NOTES 7/14/23- No Permit, energy calcs, product aproval onsite. Permit must be permanetly onsite. Drywall drop leaning on walls unable to see. Please move drywall from breaker panel unable to verify connection and ground. Stopped inspection. | |||
| ALL ROUGH | 07/14/2023 | Disapproved -FEE REQUIRED | JSTEWART |
| Note: 7/14/23- No Permit, energy calcs, product aproval onsite. Permit must be permanetly onsite. Drywall drop leaning on walls unable to see. Please move drywall from breaker panel unable to verify connection and ground. Stopped inspection. | |||
| WALL SHEATHING | 07/12/2023 | APPROVED | JSTEWART |
| Note: 7/10/2023 - PREVIOUS INSPECTION NOTES 7/10/23-Notes from 5/17/23 Not rectified. Unable to inspect wall sheathing is covered with house wrap, please remove for inspection. Inspector Notes from Inspection 2460 Trusses in question have been replaced. No letter needed 7/5/2023 - PREVIOUS INSPECTION NOTES 5/17/2023 - PREVIOUS INSPECTION NOTES Truss cords cannot be notched, drilled, or cut. FG2 has been notched to allow plumbing drain and drilled for electrical. Engineered repair required. Submit plan to building department for review. T05 missing bracing 5/2/2023 - PREVIOUS INSPECTION NOTES Job box nailed shut 7/5/23 - AS PER NSPECTION ON 5/2 - LETTER OF REPAIR IS NEEDED FOR TRUSS FG2. NO APPROVED PLANS IN CONSTRUCTION BOX. | |||
| WALL SHEATHING | 07/10/2023 | Disapproved -FEE REQUIRED | JSTEWART |
| Note: 7/10/23-Notes from 5/17/23 Not rectified. Unable to inspect wall sheathing is covered with house wrap, please remove for inspection. Inspector Notes from Inspection 2460 Trusses in question have been replaced. No letter needed 7/5/2023 - PREVIOUS INSPECTION NOTES 5/17/2023 - PREVIOUS INSPECTION NOTES Truss cords cannot be notched, drilled, or cut. FG2 has been notched to allow plumbing drain and drilled for electrical. Engineered repair required. Submit plan to building department for review. T05 missing bracing 5/2/2023 - PREVIOUS INSPECTION NOTES Job box nailed shut 7/5/23 - AS PER NSPECTION ON 5/2 - LETTER OF REPAIR IS NEEDED FOR TRUSS FG2. NO APPROVED PLANS IN CONSTRUCTION BOX. | |||
| WALL SHEATHING | 07/07/2023 | CANCELLED BY APPLICANT | WEB |
| Note: 5/17/2023 - PREVIOUS INSPECTION NOTES Wall sheathing covered with tyvek. Remove and reschedule. 5/2/2023 - PREVIOUS INSPECTION NOTES Job box nailed shut | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 07/07/2023 | APPROVED - AS NOTED | KSANDOE |
| Note: Trusses in question have been replaced. No letter needed 7/5/2023 - PREVIOUS INSPECTION NOTES 5/17/2023 - PREVIOUS INSPECTION NOTES Truss cords cannot be notched, drilled, or cut. FG2 has been notched to allow plumbing drain and drilled for electrical. Engineered repair required. Submit plan to building department for review. T05 missing bracing 5/2/2023 - PREVIOUS INSPECTION NOTES Job box nailed shut 7/5/23 - AS PER NSPECTION ON 5/2 - LETTER OF REPAIR IS NEEDED FOR TRUSS FG2. NO APPROVED PLANS IN CONSTRUCTION BOX. | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 07/05/2023 | Disapproved - NO FEE | FWILLIS |
| Note: 5/17/2023 - PREVIOUS INSPECTION NOTES Truss cords cannot be notched, drilled, or cut. FG2 has been notched to allow plumbing drain and drilled for electrical. Engineered repair required. Submit plan to building department for review. T05 missing bracing 5/2/2023 - PREVIOUS INSPECTION NOTES Job box nailed shut 7/5/23 - AS PER NSPECTION ON 5/2 - LETTER OF REPAIR IS NEEDED FOR TRUSS FG2. NO APPROVED PLANS IN CONSTRUCTION BOX. | |||
| LATH/BRICK/ WATER BARRIER | 06/27/2023 | APPROVED | JSTEWART |
| WALL SHEATHING | 05/17/2023 | Disapproved -FEE REQUIRED | KSANDOE |
| Note: Wall sheathing covered with tyvek. Remove and reschedule. 5/2/2023 - PREVIOUS INSPECTION NOTES Job box nailed shut | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 05/17/2023 | Disapproved -FEE REQUIRED | KSANDOE |
| Note: Truss cords cannot be notched, drilled, or cut. FG2 has been notched to allow plumbing drain and drilled for electrical. Engineered repair required. Submit plan to building department for review. T05 missing bracing 5/2/2023 - PREVIOUS INSPECTION NOTES Job box nailed shut | |||
| ROOF SHEATHING | 05/17/2023 | APPROVED | KSANDOE |
| Note: 5/2/2023 - PREVIOUS INSPECTION NOTES Job box nailed shut | |||
| ROOF VALLEY & METAL | 05/17/2023 | APPROVED | KSANDOE |
| ROOF SHEATHING | 05/02/2023 | Disapproved - NO FEE | KSANDOE |
| Note: Job box nailed shut | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 05/02/2023 | Disapproved - NO FEE | KSANDOE |
| Note: Job box nailed shut | |||
| WALL SHEATHING | 05/02/2023 | Disapproved -FEE REQUIRED | KSANDOE |
| Note: Job box nailed shut | |||
| FOUND SURVEY APPROVED (OFFICE) | 04/28/2023 | APPROVED | TBAKER |
| TIE BEAM / LINTEL | 04/12/2023 | APPROVED | JSTEWART |
| MONOLITHIC SLAB | 03/21/2023 | APPROVED | JSTEWART |
| PLUMBING 1ST ROUGH UNDERGROUND | 03/16/2023 | APPROVED | MGIBSON |
| WATER METER INSTALLATION REQUEST | 02/17/2023 | APPROVED | TSCHWEERS |
Review History
| Department | Status | Date In | Date Out |
| BADMIN | INFORMATION | 01/16/2024 | 01/16/2024 |
| Note: Marked INFORMATION By: BARBIE BEMBRY - (386)986-3780 - BUILDINGDIVISION@PALMCOASTGOV.COM repeat comment We are unabel to process the final survey . The NOC is expired. | |||
| BADMIN | INFORMATION | 01/15/2024 | 01/15/2024 |
| Note: Marked INFORMATION By: BARBIE BEMBRY - (386)986-3780 - BUILDINGDIVISION@PALMCOASTGOV.COM We are unable to process the final survey . The NOC is expired. | |||
| MECH | COMPLETE | 08/31/2023 | 09/05/2023 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 04/27/2023 | 04/28/2023 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 04/27/2023 | 04/27/2023 |
| Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 02/21/2023 | 02/22/2023 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 02/08/2023 | 02/09/2023 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| MECH | HOLD | 02/02/2023 | 02/03/2023 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Duct layout needs to be signed by the AC contractor per 107.1 FBC Residential 2020 7th Edition | |||
| ZON | COMPLETE | 01/06/2023 | 01/06/2023 |
| Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 01/06/2023 | 01/06/2023 |
| Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM | |||
| SWALE | COMPLETE | 12/28/2022 | 04/10/2023 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 12/27/2022 | 12/28/2022 |
| Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM | |||
| CUSVC | COMPLETE | 12/27/2022 | 12/29/2022 |
| Note: Released By: HALEIGH HAND - - | |||
| ELEC | COMPLETE | 12/27/2022 | 12/28/2022 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 12/27/2022 | 12/28/2022 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| LOCATE | COMPLETE | 12/27/2022 | 12/28/2022 |
| Note: Released By: CANDACE STONE - - CSTONE@PALMCOASTGOV.COM | |||
| MECH | HOLD | 12/27/2022 | 12/28/2022 |
| Note: Held By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM All comments below per the 2020 Florida Building Code – Plumbing REVIEW COMMENTS: 1. Design location on Energy Forms is to be Daytona Beach. 2. Form 405 is to be signed by Owner/Agent | |||
| SW1 | COMPLETE | 12/27/2022 | 01/05/2023 |
| Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM | |||
| ZON | HOLD | 12/27/2022 | 12/28/2022 |
| Note: Held By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM Site Plan missing: Walkway Width Landscape: Screen Planting for the A/C must be 7 gallons and show proposed sod and if it will need irrigation. Please choose Shrubs for the foundation plantings that will be toloerant in our area this shrub Arboricola is also known as Dwarf Schefflera and is on the non credit planting list. Please look up the commonly used approved shrubs like Holly, vibumum, ligustrum those are tolerant in our area. |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION RESIDENTIAL | ¤40.00 | 12/22/2023 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 12/22/2023 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 12/22/2023 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 12/22/2023 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 12/22/2023 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 12/22/2023 |
| SW ENG REINSPECTION 30 | ¤30.00 | 12/22/2023 |
| SW ENG REINSPECTION 30 | ¤30.00 | 12/22/2023 |
| SW ENG REINSPECTION 30 | ¤30.00 | 12/22/2023 |
| CONTRACTOR CHANGE | ¤20.00 | 04/13/2023 |
| PLAN REVIEW - REVISION | ¤32.50 | 04/13/2023 |
| PLAN REVIEW - REVISION | ¤32.50 | 04/13/2023 |
| FIRE IMPACT FEE ADMIN | ¤12.62 | 01/23/2023 |
| FIRE IMPACT FEE ADMIN | (¤12.62) | 01/23/2023 |
| FC IMPACT FEE EMS | ¤62.00 | 01/23/2023 |
| IMPACT FEE FIRE | ¤420.52 | 01/23/2023 |
| FC IMPACT FEE LAW ENFORCEMENT | ¤218.00 | 01/23/2023 |
| FC IMPACT FEE LIBRARY | ¤268.00 | 01/23/2023 |
| IMPACT FEE PARKS | ¤1,769.15 | 01/23/2023 |
| IMPACT FEE SCHOOL | ¤5,450.00 | 01/23/2023 |
| IMPACT FEE TRANSPORTATION | ¤1,764.00 | 01/23/2023 |
| WATER -IRRIGATION INSPECTION | ¤25.00 | 01/23/2023 |
| PARKS IMPACT FEE ADMIN | ¤53.07 | 01/23/2023 |
| PARKS IMPACT FEE ADMIN | (¤53.07) | 01/23/2023 |
| SURCHARGE FS 533.721 | ¤2.89 | 01/23/2023 |
| SURCHARGE - FS 468.631 | ¤4.33 | 01/23/2023 |
| SW ENG - FOUNDATION SURVEY | ¤20.00 | 01/23/2023 |
| SW ENG INSPECTION 80 | ¤80.00 | 01/23/2023 |
| SW ENG PRE APRON | ¤30.00 | 01/23/2023 |
| SW ENG - REVIEW 20 | ¤20.00 | 01/23/2023 |
| SW ENG RES REVIEW 200 | ¤200.00 | 01/23/2023 |
| TRANS IMPACT FEE ADMIN | ¤52.92 | 01/23/2023 |
| TRANS IMPACT FEE ADMIN | (¤52.92) | 01/23/2023 |
| SEWER CREDIT | (¤850.00) | 01/23/2023 |
| SEWER INSPECTION | ¤25.00 | 01/23/2023 |
| SEWER CAPITAL FACILITY | ¤5,344.82 | 01/23/2023 |
| WATER CAPITAL FACILITY FEE | ¤3,923.88 | 01/23/2023 |
| SITE PLAN 30 | ¤30.00 | 01/23/2023 |
| CONNECTION FEES | ¤1,166.26 | 01/23/2023 |
| WATER- TURN ON | ¤25.00 | 01/23/2023 |
| ADJUSTMENT 50% | (¤438.60) | 01/23/2023 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 01/23/2023 |
| INSPECTION - RESIDENTIAL | ¤660.00 | 01/23/2023 |
| PLAN REVIEW - RESIDENTIAL | ¤187.20 | 01/23/2023 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤20,852.45 |