Permit #2022120992

Permit Details

Status: COED

Parcel Id: 07-11-31-7035-01110-0060
CONDITIONED SPACE: 1906 sqft
GARAGE: 400 sqft
OPENED PORCH (WITH ROOF) : 20 sqft
Total Square Footage: 2326 sqft
Block: 01110
Subdivision: 2172 - SECTION 35-BELLE TERRE
Job Phone: 470-817-1259
Location Address: 52 BISCAYNE DR
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 01/23/2023
NOC: RECORDED
Applicant name: WADE GILMER JURNEY JR
Owner: NATIONAL HOME CORPORATION

Address

1080 HOLCOMB BRIDGE ROAD 100-330

ROSWELL, GA 30076

Lot: 0060
Contracted Stated Job Value: ¤239,639.00
Job Description: Single Family Residence
Type: CN

Contractor

NATIONAL HOME CORPORATION
Status Location Address Mailing Address State License Number Phone
INACTIVE

1080 HOLCOMB BRIDGE ROAD

,

BLDG 100 - 330

ROSWELL , GA 30076

CBC1257700 (Exp: 08/31/2026) 471-817-1259

Sub Contractors

RANDALL SCOTT ROSENFELD
Status Location Address State License Number Phone
ACTIVE

234 N WHITNEY ST

PALM COAST, FL 32084

CAC1816641 (Exp: 08/31/2026) 904-599-0082
DUSTIN L ESTEP
Status Location Address State License Number Phone Fax
ACTIVE

2041 N HIAWASSEE RD

APOPKA, FL 32703

CCC1330971 (Exp: 08/31/2026) 407-702-0206 352-988-6629
JASON PATRICK RIBOCK
Status Location Address State License Number Phone
INACTIVE

620 E PINE ST

, 0

ES12001313 (Exp: 08/31/2026) 407-625-0257
PAUL ERIC FORSTER
Status Location Address State License Number Phone
ACTIVE

6114 GOODMAN RD

JACKSONVILLE, FL 32244

CFC1429261 (Exp: 08/31/2026) 904-647-1820

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 01/26/2024 FINAL APPROVED JSTEWART
Note: 1/25/2024 - PREVIOUS INSPECTION NOTES 1/25/24- 1. Please extend Hot water Auxillary pan discharge. 504.7.2 Pan drain termination....terminate not less than 6 inches (152 mm) and not more than 24 inches (610 mm) above the adjacent ground surface. 2. No Hot water. 3. Please seal off interior of Dryer duct. (Unless Dryer is installed.) Inspector Notes from Inspection 2490 8/31/23- Energy calcs onsite Match whats installed for returns, but revision needs to be submitted and aproved by the city. please obtain revision. before final. 8/29/2023 - PREVIOUS INSPECTION NOTES 8/29/23- Previous note not rectified....2nd floor header returns installed are smaller size then on energy calcs. (10x6 vs 24x4). Please obtain revision of what is installed or install per plan. will check at insulation. Double wall 2nd floor needs to be fire stopped at joining seam. please seal floor penetration at 2nd floor condensation pipe. No Address displayed....R319.1 Address identification. Buildings shall be provided with approved address identification. The address identification shall be legible and placed in a position that is visible from the street or road fronting the property Inspector Notes from Inspection 2420 8/10/23- 2nd floor header returns installed are smaller size then on energy calcs. (10x6 vs 24x4). Please obtain revision of what is installed or install per plan. will check at insulation. 7/14/2023 - PREVIOUS INSPECTION NOTES 7/14/23- No Permit, energy calcs, product aproval onsite. Permit must be permanetly onsite. Drywall drop leaning on walls unable to see. Please move drywall from breaker panel unable to verify connection and ground. Stopped inspection.
U-CROSS CONNECTION 01/25/2024 APPROVED DHANEY
BLD - BUILDING FINAL 01/25/2024 Disapproved - NO FEE JSTEWART
Note: 1/25/24- 1. Please extend Hot water Auxillary pan discharge. 504.7.2 Pan drain termination....terminate not less than 6 inches (152 mm) and not more than 24 inches (610 mm) above the adjacent ground surface. 2. No Hot water. 3. Please seal off interior of Dryer duct. (Unless Dryer is installed.) Inspector Notes from Inspection 2490 8/31/23- Energy calcs onsite Match whats installed for returns, but revision needs to be submitted and aproved by the city. please obtain revision. before final. 8/29/2023 - PREVIOUS INSPECTION NOTES 8/29/23- Previous note not rectified....2nd floor header returns installed are smaller size then on energy calcs. (10x6 vs 24x4). Please obtain revision of what is installed or install per plan. will check at insulation. Double wall 2nd floor needs to be fire stopped at joining seam. please seal floor penetration at 2nd floor condensation pipe. No Address displayed....R319.1 Address identification. Buildings shall be provided with approved address identification. The address identification shall be legible and placed in a position that is visible from the street or road fronting the property Inspector Notes from Inspection 2420 8/10/23- 2nd floor header returns installed are smaller size then on energy calcs. (10x6 vs 24x4). Please obtain revision of what is installed or install per plan. will check at insulation. 7/14/2023 - PREVIOUS INSPECTION NOTES 7/14/23- No Permit, energy calcs, product aproval onsite. Permit must be permanetly onsite. Drywall drop leaning on walls unable to see. Please move drywall from breaker panel unable to verify connection and ground. Stopped inspection.
ROW- FINAL SURVEY/GRADING CERTIFICATION 01/24/2024 APPROVED TPOLACEK
Note: 01/24/24 UPON WALKING PROPERTY DRAINAGE WILL WORK AS INDICATED ON FINAL SURVEY. AT THE TIME FROM THE TIME OF THE INSPECTION OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. Inspector Notes from Inspection 9270 ** 12/14/23 READY TO POUR ** At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved. This includes but is not limited to, the Culvert Pipe Elevation from the time of the inspection approval to the concrete pour. ** Sec.900.04C Residential driveways shall be constructed using material with a minimum of three thousand pounds (3,000 Ibs.) per square inch with Fiber or wire mesh. ___________________________________________________________________________________________________________________ 12/12/2023 - PREVIOUS INSPECTION NOTES ** 12/12/23 BUILDER NEEDS TO REVIEW ALL NOTES LEFT BY THE INSPECTOR CENTER OF CULVERT NEEDS TO BE 8 FEET FROM EDGE OF ROAD. RECHECK YOUR EDGE OF ROAD FORM BOARDS. ** CULVERT FOOTS AT THE MITERED ENDS NEED TO BE 6INCHES X 6INCHES X 18INCHES ** CULVERT NEEDS TO BE BURIED HALFWAY UP YOURS HAS NO MATERIAL AROUND IT CULVERT IS JUST SITTING ON GROUND WITH NO MATERIAL HOLDING IT IN PLACE NEED TO HAVE A SLOPE AS SHOWN IN DIAGRAM 300.E ON EITHER SIDE OF CULVERT ** SEE PHOTOGRAPHS OF THE CULVERT DETAIL NOTE THE CIRCLED AREAS FOR YOUR CORRECTION ON THE CULVERT DETAIL PLAN LEFT IN THE PICTURE AREA OF THIS INSPECTION ______________________________________________________________________________________________________________________ 12/11/2023 - PREVIOUS INSPECTION NOTES 12/11/23 ** AT TIME OF INSPECTION PIPE IS GOOD. RIGHT SIDE APRON END NEEDS TO BE BROUGHT BACK BEHIND EDGE OF ROAD ( SEE PHOTO) ALSO BOTH MITER END FOOTERS NEED TO BE DUG OUT TO A MINUMUM OF 6" DEEP.A minimum footer of six (6) inches by six (6) is required under each culvert end, not to extend past the end of the MES. ____________________________________________________________________________ 11/17/2023 - PREVIOUS INSPECTION NOTES ** 11/17/23 SITE IS FLOODED NOT READY FOR INSPECTION ** SEE ATTACHED PHOTOS _________________________________________________________________________________________________________________________ 11/15/2023 - PREVIOUS INSPECTION NOTES ** 11/15/23 ADDRESS MUST BE POSTED AND PLAINLY VISIBLE TO INSPECTORS. IF ADDRESS IS NOT PLAINLY VISIBLE, INSPECTORS WILL NOT PERFORM INSPECTIONS AND A REINSPECTION FEE WILL BE ISSUED. Florida Building Code-Building Section 501.2 01/24/24 UPON WALKING PROPERTY DRAINAGE WILL WORK AS INDICATED ON FINAL SURVEY. AT THE TIME FROM THE TIME OF THE INSPECTION OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. Inspector Notes from Inspection 9270 ** 12/14/23 READY TO POUR ** At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved. This includes but is not limited to, the Culvert Pipe Elevation from the time of the inspection approval to the concrete pour. ** Sec.900.04C Residential driveways shall be constructed using material with a minimum of three thousand pounds (3,000 Ibs.) per square inch with Fiber or wire mesh. ___________________________________________________________________________________________________________________ 12/12/2023 - PREVIOUS INSPECTION NOTES ** 12/12/23 BUILDER NEEDS TO REVIEW ALL NOTES LEFT BY THE INSPECTOR CENTER OF CULVERT NEEDS TO BE 8 FEET FROM EDGE OF ROAD. RECHECK YOUR EDGE OF ROAD FORM BOARDS. ** CULVERT FOOTS AT THE MITERED ENDS NEED TO BE 6INCHES X 6INCHES X 18INCHES ** CULVERT NEEDS TO BE BURIED HALFWAY UP YOURS HAS NO MATERIAL AROUND IT CULVERT IS JUST SITTING ON GROUND WITH NO MATERIAL HOLDING IT IN PLACE NEED TO HAVE A SLOPE AS SHOWN IN DIAGRAM 300.E ON EITHER SIDE OF CULVERT ** SEE PHOTOGRAPHS OF THE CULVERT DETAIL NOTE THE CIRCLED AREAS FOR YOUR CORRECTION ON THE CULVERT DETAIL PLAN LEFT IN THE PICTURE AREA OF THIS INSPECTION ______________________________________________________________________________________________________________________ 12/11/2023 - PREVIOUS INSPECTION NOTES 12/11/23 ** AT TIME OF INSPECTION PIPE IS GOOD. RIGHT SIDE APRON END NEEDS TO BE BROUGHT BACK BEHIND EDGE OF ROAD ( SEE PHOTO) ALSO BOTH MITER END FOOTERS NEED TO BE DUG OUT TO A MINUMUM OF 6" DEEP.A minimum footer of six (6) inches by six (6) is required under each culvert end, not to extend past the end of the MES. ____________________________________________________________________________ 11/17/2023 - PREVIOUS INSPECTION NOTES ** 11/17/23 SITE IS FLOODED NOT READY FOR INSPECTION ** SEE ATTACHED PHOTOS _________________________________________________________________________________________________________________________ 11/15/2023 - PREVIOUS INSPECTION NOTES ** 11/15/23 ADDRESS MUST BE POSTED AND PLAINLY VISIBLE TO INSPECTORS. IF ADDRESS IS NOT PLAINLY VISIBLE, INSPECTORS WILL NOT PERFORM INSPECTIONS AND A REINSPECTION FEE WILL BE ISSUED. Florida Building Code-Building Section 501.2
ROW FIELD SURVEY /GRADING CERTIFICATION 01/24/2024 APPROVED TPOLACEK
Note: 01/24/24 AT THE TIME FROM THE TIME OF THE INSPECTION OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED.
ROW - STORMWATER FINAL 01/24/2024 APPROVED TPOLACEK
Note: AT THE TIME FROM THE TIME OF THE INSPECTION OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED
U -UTILITY RESIDENTIAL FINAL 01/24/2024 CANCELLED BY INSPECTOR TPOLACEK
Note: SORRY LARRY CREATED BY ACCIDENT
ROW - FINAL APRON (AFTER POUR) 01/24/2024 APPROVED TPOLACEK
Note: 01/24/24 PIPE IS GOOD, CUTS ARE MADE, CULVERT CLEAR, HOT PATCH COMPLETE. AT THE TIME FROM THE TIME OF THE INSPECTION OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED.
ROW- PRE-APRON (PRE-POUR) 12/14/2023 APPROVED - AS NOTED EMADISON
Note: ** 12/14/23 READY TO POUR ** At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved. This includes but is not limited to, the Culvert Pipe Elevation from the time of the inspection approval to the concrete pour. ** Sec.900.04C Residential driveways shall be constructed using material with a minimum of three thousand pounds (3,000 Ibs.) per square inch with Fiber or wire mesh. ___________________________________________________________________________________________________________________ 12/12/2023 - PREVIOUS INSPECTION NOTES ** 12/12/23 BUILDER NEEDS TO REVIEW ALL NOTES LEFT BY THE INSPECTOR CENTER OF CULVERT NEEDS TO BE 8 FEET FROM EDGE OF ROAD. RECHECK YOUR EDGE OF ROAD FORM BOARDS. ** CULVERT FOOTS AT THE MITERED ENDS NEED TO BE 6INCHES X 6INCHES X 18INCHES ** CULVERT NEEDS TO BE BURIED HALFWAY UP YOURS HAS NO MATERIAL AROUND IT CULVERT IS JUST SITTING ON GROUND WITH NO MATERIAL HOLDING IT IN PLACE NEED TO HAVE A SLOPE AS SHOWN IN DIAGRAM 300.E ON EITHER SIDE OF CULVERT ** SEE PHOTOGRAPHS OF THE CULVERT DETAIL NOTE THE CIRCLED AREAS FOR YOUR CORRECTION ON THE CULVERT DETAIL PLAN LEFT IN THE PICTURE AREA OF THIS INSPECTION ______________________________________________________________________________________________________________________ 12/11/2023 - PREVIOUS INSPECTION NOTES 12/11/23 ** AT TIME OF INSPECTION PIPE IS GOOD. RIGHT SIDE APRON END NEEDS TO BE BROUGHT BACK BEHIND EDGE OF ROAD ( SEE PHOTO) ALSO BOTH MITER END FOOTERS NEED TO BE DUG OUT TO A MINUMUM OF 6" DEEP.A minimum footer of six (6) inches by six (6) is required under each culvert end, not to extend past the end of the MES. ____________________________________________________________________________ 11/17/2023 - PREVIOUS INSPECTION NOTES ** 11/17/23 SITE IS FLOODED NOT READY FOR INSPECTION ** SEE ATTACHED PHOTOS _________________________________________________________________________________________________________________________ 11/15/2023 - PREVIOUS INSPECTION NOTES ** 11/15/23 ADDRESS MUST BE POSTED AND PLAINLY VISIBLE TO INSPECTORS. IF ADDRESS IS NOT PLAINLY VISIBLE, INSPECTORS WILL NOT PERFORM INSPECTIONS AND A REINSPECTION FEE WILL BE ISSUED. Florida Building Code-Building Section 501.2
ROW- PRE-APRON (PRE-POUR) 12/12/2023 Disapproved -FEE REQUIRED EMADISON
Note: ** 12/12/23 BUILDER NEEDS TO REVIEW ALL NOTES LEFT BY THE INSPECTOR CENTER OF CULVERT NEEDS TO BE 8 FEET FROM EDGE OF ROAD. RECHECK YOUR EDGE OF ROAD FORM BOARDS. ** CULVERT FOOTS AT THE MITERED ENDS NEED TO BE 6INCHES X 6INCHES X 18INCHES ** CULVERT NEEDS TO BE BURIED HALFWAY UP YOURS HAS NO MATERIAL AROUND IT CULVERT IS JUST SITTING ON GROUND WITH NO MATERIAL HOLDING IT IN PLACE NEED TO HAVE A SLOPE AS SHOWN IN DIAGRAM 300.E ON EITHER SIDE OF CULVERT ** SEE PHOTOGRAPHS OF THE CULVERT DETAIL NOTE THE CIRCLED AREAS FOR YOUR CORRECTION ON THE CULVERT DETAIL PLAN LEFT IN THE PICTURE AREA OF THIS INSPECTION ______________________________________________________________________________________________________________________ 12/11/2023 - PREVIOUS INSPECTION NOTES 12/11/23 ** AT TIME OF INSPECTION PIPE IS GOOD. RIGHT SIDE APRON END NEEDS TO BE BROUGHT BACK BEHIND EDGE OF ROAD ( SEE PHOTO) ALSO BOTH MITER END FOOTERS NEED TO BE DUG OUT TO A MINUMUM OF 6" DEEP.A minimum footer of six (6) inches by six (6) is required under each culvert end, not to extend past the end of the MES. ____________________________________________________________________________ 11/17/2023 - PREVIOUS INSPECTION NOTES ** 11/17/23 SITE IS FLOODED NOT READY FOR INSPECTION ** SEE ATTACHED PHOTOS _________________________________________________________________________________________________________________________ 11/15/2023 - PREVIOUS INSPECTION NOTES ** 11/15/23 ADDRESS MUST BE POSTED AND PLAINLY VISIBLE TO INSPECTORS. IF ADDRESS IS NOT PLAINLY VISIBLE, INSPECTORS WILL NOT PERFORM INSPECTIONS AND A REINSPECTION FEE WILL BE ISSUED. Florida Building Code-Building Section 501.2
ROW- PRE-APRON (PRE-POUR) 12/11/2023 Disapproved -FEE REQUIRED TPOLACEK
Note: 12/11/23 ** AT TIME OF INSPECTION PIPE IS GOOD. RIGHT SIDE APRON END NEEDS TO BE BROUGHT BACK BEHIND EDGE OF ROAD ( SEE PHOTO) ALSO BOTH MITER END FOOTERS NEED TO BE DUG OUT TO A MINUMUM OF 6" DEEP.A minimum footer of six (6) inches by six (6) is required under each culvert end, not to extend past the end of the MES. ____________________________________________________________________________ 11/17/2023 - PREVIOUS INSPECTION NOTES ** 11/17/23 SITE IS FLOODED NOT READY FOR INSPECTION ** SEE ATTACHED PHOTOS _________________________________________________________________________________________________________________________ 11/15/2023 - PREVIOUS INSPECTION NOTES ** 11/15/23 ADDRESS MUST BE POSTED AND PLAINLY VISIBLE TO INSPECTORS. IF ADDRESS IS NOT PLAINLY VISIBLE, INSPECTORS WILL NOT PERFORM INSPECTIONS AND A REINSPECTION FEE WILL BE ISSUED. Florida Building Code-Building Section 501.2
ROW- PRE-APRON (PRE-POUR) 11/17/2023 Disapproved -FEE REQUIRED EMADISON
Note: ** 11/17/23 SITE IS FLOODED NOT READY FOR INSPECTION ** SEE ATTACHED PHOTOS _________________________________________________________________________________________________________________________ 11/15/2023 - PREVIOUS INSPECTION NOTES ** 11/15/23 ADDRESS MUST BE POSTED AND PLAINLY VISIBLE TO INSPECTORS. IF ADDRESS IS NOT PLAINLY VISIBLE, INSPECTORS WILL NOT PERFORM INSPECTIONS AND A REINSPECTION FEE WILL BE ISSUED. Florida Building Code-Building Section 501.2
ELECTRIC - EARLY POWER 11/17/2023 APPROVED - AS NOTED JSTEWART
Note: 11/17/23- Authorize release of email to FPL @ 9:21a
ROW- PRE-APRON (PRE-POUR) 11/15/2023 Disapproved - NO FEE EMADISON
Note: ** 11/15/23 ADDRESS MUST BE POSTED AND PLAINLY VISIBLE TO INSPECTORS. IF ADDRESS IS NOT PLAINLY VISIBLE, INSPECTORS WILL NOT PERFORM INSPECTIONS AND A REINSPECTION FEE WILL BE ISSUED. Florida Building Code-Building Section 501.2
GRAVITY SEWER TEST 10/13/2023 APPROVED - AS NOTED MGIBSON
Note: THIS WAS A VIRTUAL INSPECTION
U - SEWER TIE IN 10/13/2023 APPROVED - AS NOTED MGIBSON
Note: THIS WAS A VIRTUAL INSPECTION
PEP TANK INSTALLATION REQUEST 09/06/2023 APPROVED CBOWERMASTER
INSULATION 08/31/2023 APPROVED - AS NOTED JSTEWART
Note: 8/31/23- Energy calcs onsite Match whats installed for returns, but revision needs to be submitted and aproved by the city. please obtain revision. before final. 8/29/2023 - PREVIOUS INSPECTION NOTES 8/29/23- Previous note not rectified....2nd floor header returns installed are smaller size then on energy calcs. (10x6 vs 24x4). Please obtain revision of what is installed or install per plan. will check at insulation. Double wall 2nd floor needs to be fire stopped at joining seam. please seal floor penetration at 2nd floor condensation pipe. No Address displayed....R319.1 Address identification. Buildings shall be provided with approved address identification. The address identification shall be legible and placed in a position that is visible from the street or road fronting the property Inspector Notes from Inspection 2420 8/10/23- 2nd floor header returns installed are smaller size then on energy calcs. (10x6 vs 24x4). Please obtain revision of what is installed or install per plan. will check at insulation. 7/14/2023 - PREVIOUS INSPECTION NOTES 7/14/23- No Permit, energy calcs, product aproval onsite. Permit must be permanetly onsite. Drywall drop leaning on walls unable to see. Please move drywall from breaker panel unable to verify connection and ground. Stopped inspection.
INSULATION 08/29/2023 Disapproved -FEE REQUIRED JSTEWART
Note: 8/29/23- Previous note not rectified....2nd floor header returns installed are smaller size then on energy calcs. (10x6 vs 24x4). Please obtain revision of what is installed or install per plan. will check at insulation. Double wall 2nd floor needs to be fire stopped at joining seam. please seal floor penetration at 2nd floor condensation pipe. No Address displayed....R319.1 Address identification. Buildings shall be provided with approved address identification. The address identification shall be legible and placed in a position that is visible from the street or road fronting the property Inspector Notes from Inspection 2420 8/10/23- 2nd floor header returns installed are smaller size then on energy calcs. (10x6 vs 24x4). Please obtain revision of what is installed or install per plan. will check at insulation. 7/14/2023 - PREVIOUS INSPECTION NOTES 7/14/23- No Permit, energy calcs, product aproval onsite. Permit must be permanetly onsite. Drywall drop leaning on walls unable to see. Please move drywall from breaker panel unable to verify connection and ground. Stopped inspection.
ALL ROUGH 08/10/2023 APPROVED - AS NOTED JSTEWART
Note: 8/10/23- 2nd floor header returns installed are smaller size then on energy calcs. (10x6 vs 24x4). Please obtain revision of what is installed or install per plan. will check at insulation. 7/14/2023 - PREVIOUS INSPECTION NOTES 7/14/23- No Permit, energy calcs, product aproval onsite. Permit must be permanetly onsite. Drywall drop leaning on walls unable to see. Please move drywall from breaker panel unable to verify connection and ground. Stopped inspection.
ALL ROUGH 07/14/2023 Disapproved -FEE REQUIRED JSTEWART
Note: 7/14/23- No Permit, energy calcs, product aproval onsite. Permit must be permanetly onsite. Drywall drop leaning on walls unable to see. Please move drywall from breaker panel unable to verify connection and ground. Stopped inspection.
WALL SHEATHING 07/12/2023 APPROVED JSTEWART
Note: 7/10/2023 - PREVIOUS INSPECTION NOTES 7/10/23-Notes from 5/17/23 Not rectified. Unable to inspect wall sheathing is covered with house wrap, please remove for inspection. Inspector Notes from Inspection 2460 Trusses in question have been replaced. No letter needed 7/5/2023 - PREVIOUS INSPECTION NOTES 5/17/2023 - PREVIOUS INSPECTION NOTES Truss cords cannot be notched, drilled, or cut. FG2 has been notched to allow plumbing drain and drilled for electrical. Engineered repair required. Submit plan to building department for review. T05 missing bracing 5/2/2023 - PREVIOUS INSPECTION NOTES Job box nailed shut 7/5/23 - AS PER NSPECTION ON 5/2 - LETTER OF REPAIR IS NEEDED FOR TRUSS FG2. NO APPROVED PLANS IN CONSTRUCTION BOX.
WALL SHEATHING 07/10/2023 Disapproved -FEE REQUIRED JSTEWART
Note: 7/10/23-Notes from 5/17/23 Not rectified. Unable to inspect wall sheathing is covered with house wrap, please remove for inspection. Inspector Notes from Inspection 2460 Trusses in question have been replaced. No letter needed 7/5/2023 - PREVIOUS INSPECTION NOTES 5/17/2023 - PREVIOUS INSPECTION NOTES Truss cords cannot be notched, drilled, or cut. FG2 has been notched to allow plumbing drain and drilled for electrical. Engineered repair required. Submit plan to building department for review. T05 missing bracing 5/2/2023 - PREVIOUS INSPECTION NOTES Job box nailed shut 7/5/23 - AS PER NSPECTION ON 5/2 - LETTER OF REPAIR IS NEEDED FOR TRUSS FG2. NO APPROVED PLANS IN CONSTRUCTION BOX.
WALL SHEATHING 07/07/2023 CANCELLED BY APPLICANT WEB
Note: 5/17/2023 - PREVIOUS INSPECTION NOTES Wall sheathing covered with tyvek. Remove and reschedule. 5/2/2023 - PREVIOUS INSPECTION NOTES Job box nailed shut
ROOF SHEATHING / BRACES/TIES/DOWN CELL 07/07/2023 APPROVED - AS NOTED KSANDOE
Note: Trusses in question have been replaced. No letter needed 7/5/2023 - PREVIOUS INSPECTION NOTES 5/17/2023 - PREVIOUS INSPECTION NOTES Truss cords cannot be notched, drilled, or cut. FG2 has been notched to allow plumbing drain and drilled for electrical. Engineered repair required. Submit plan to building department for review. T05 missing bracing 5/2/2023 - PREVIOUS INSPECTION NOTES Job box nailed shut 7/5/23 - AS PER NSPECTION ON 5/2 - LETTER OF REPAIR IS NEEDED FOR TRUSS FG2. NO APPROVED PLANS IN CONSTRUCTION BOX.
ROOF SHEATHING / BRACES/TIES/DOWN CELL 07/05/2023 Disapproved - NO FEE FWILLIS
Note: 5/17/2023 - PREVIOUS INSPECTION NOTES Truss cords cannot be notched, drilled, or cut. FG2 has been notched to allow plumbing drain and drilled for electrical. Engineered repair required. Submit plan to building department for review. T05 missing bracing 5/2/2023 - PREVIOUS INSPECTION NOTES Job box nailed shut 7/5/23 - AS PER NSPECTION ON 5/2 - LETTER OF REPAIR IS NEEDED FOR TRUSS FG2. NO APPROVED PLANS IN CONSTRUCTION BOX.
LATH/BRICK/ WATER BARRIER 06/27/2023 APPROVED JSTEWART
WALL SHEATHING 05/17/2023 Disapproved -FEE REQUIRED KSANDOE
Note: Wall sheathing covered with tyvek. Remove and reschedule. 5/2/2023 - PREVIOUS INSPECTION NOTES Job box nailed shut
ROOF SHEATHING / BRACES/TIES/DOWN CELL 05/17/2023 Disapproved -FEE REQUIRED KSANDOE
Note: Truss cords cannot be notched, drilled, or cut. FG2 has been notched to allow plumbing drain and drilled for electrical. Engineered repair required. Submit plan to building department for review. T05 missing bracing 5/2/2023 - PREVIOUS INSPECTION NOTES Job box nailed shut
ROOF SHEATHING 05/17/2023 APPROVED KSANDOE
Note: 5/2/2023 - PREVIOUS INSPECTION NOTES Job box nailed shut
ROOF VALLEY & METAL 05/17/2023 APPROVED KSANDOE
ROOF SHEATHING 05/02/2023 Disapproved - NO FEE KSANDOE
Note: Job box nailed shut
ROOF SHEATHING / BRACES/TIES/DOWN CELL 05/02/2023 Disapproved - NO FEE KSANDOE
Note: Job box nailed shut
WALL SHEATHING 05/02/2023 Disapproved -FEE REQUIRED KSANDOE
Note: Job box nailed shut
FOUND SURVEY APPROVED (OFFICE) 04/28/2023 APPROVED TBAKER
TIE BEAM / LINTEL 04/12/2023 APPROVED JSTEWART
MONOLITHIC SLAB 03/21/2023 APPROVED JSTEWART
PLUMBING 1ST ROUGH UNDERGROUND 03/16/2023 APPROVED MGIBSON
WATER METER INSTALLATION REQUEST 02/17/2023 APPROVED TSCHWEERS

Review History

Department Status Date In Date Out
BADMIN INFORMATION 01/16/2024 01/16/2024
Note: Marked INFORMATION By: BARBIE BEMBRY - (386)986-3780 - BUILDINGDIVISION@PALMCOASTGOV.COM repeat comment We are unabel to process the final survey . The NOC is expired.
BADMIN INFORMATION 01/15/2024 01/15/2024
Note: Marked INFORMATION By: BARBIE BEMBRY - (386)986-3780 - BUILDINGDIVISION@PALMCOASTGOV.COM We are unable to process the final survey . The NOC is expired.
MECH COMPLETE 08/31/2023 09/05/2023
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
ENGIN1 COMPLETE 04/27/2023 04/28/2023
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON COMPLETE 04/27/2023 04/27/2023
Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM
BLD COMPLETE 02/21/2023 02/22/2023
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
MECH COMPLETE 02/08/2023 02/09/2023
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
MECH HOLD 02/02/2023 02/03/2023
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Duct layout needs to be signed by the AC contractor per 107.1 FBC Residential 2020 7th Edition
ZON COMPLETE 01/06/2023 01/06/2023
Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM
MECH COMPLETE 01/06/2023 01/06/2023
Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM
SWALE COMPLETE 12/28/2022 04/10/2023
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
BLD COMPLETE 12/27/2022 12/28/2022
Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM
CUSVC COMPLETE 12/27/2022 12/29/2022
Note: Released By: HALEIGH HAND - -
ELEC COMPLETE 12/27/2022 12/28/2022
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ENGIN1 COMPLETE 12/27/2022 12/28/2022
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
LOCATE COMPLETE 12/27/2022 12/28/2022
Note: Released By: CANDACE STONE - - CSTONE@PALMCOASTGOV.COM
MECH HOLD 12/27/2022 12/28/2022
Note: Held By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM All comments below per the 2020 Florida Building Code – Plumbing REVIEW COMMENTS: 1. Design location on Energy Forms is to be Daytona Beach. 2. Form 405 is to be signed by Owner/Agent
SW1 COMPLETE 12/27/2022 01/05/2023
Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM
ZON HOLD 12/27/2022 12/28/2022
Note: Held By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM Site Plan missing: Walkway Width Landscape: Screen Planting for the A/C must be 7 gallons and show proposed sod and if it will need irrigation. Please choose Shrubs for the foundation plantings that will be toloerant in our area this shrub Arboricola is also known as Dwarf Schefflera and is on the non credit planting list. Please look up the commonly used approved shrubs like Holly, vibumum, ligustrum those are tolerant in our area.

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION RESIDENTIAL ¤40.00 12/22/2023
REINSPECTION RESIDENTIAL ¤40.00 12/22/2023
REINSPECTION RESIDENTIAL ¤40.00 12/22/2023
REINSPECTION RESIDENTIAL ¤40.00 12/22/2023
REINSPECTION RESIDENTIAL ¤40.00 12/22/2023
REINSPECTION RESIDENTIAL ¤40.00 12/22/2023
SW ENG REINSPECTION 30 ¤30.00 12/22/2023
SW ENG REINSPECTION 30 ¤30.00 12/22/2023
SW ENG REINSPECTION 30 ¤30.00 12/22/2023
CONTRACTOR CHANGE ¤20.00 04/13/2023
PLAN REVIEW - REVISION ¤32.50 04/13/2023
PLAN REVIEW - REVISION ¤32.50 04/13/2023
FIRE IMPACT FEE ADMIN ¤12.62 01/23/2023
FIRE IMPACT FEE ADMIN (¤12.62) 01/23/2023
FC IMPACT FEE EMS ¤62.00 01/23/2023
IMPACT FEE FIRE ¤420.52 01/23/2023
FC IMPACT FEE LAW ENFORCEMENT ¤218.00 01/23/2023
FC IMPACT FEE LIBRARY ¤268.00 01/23/2023
IMPACT FEE PARKS ¤1,769.15 01/23/2023
IMPACT FEE SCHOOL ¤5,450.00 01/23/2023
IMPACT FEE TRANSPORTATION ¤1,764.00 01/23/2023
WATER -IRRIGATION INSPECTION ¤25.00 01/23/2023
PARKS IMPACT FEE ADMIN ¤53.07 01/23/2023
PARKS IMPACT FEE ADMIN (¤53.07) 01/23/2023
SURCHARGE FS 533.721 ¤2.89 01/23/2023
SURCHARGE - FS 468.631 ¤4.33 01/23/2023
SW ENG - FOUNDATION SURVEY ¤20.00 01/23/2023
SW ENG INSPECTION 80 ¤80.00 01/23/2023
SW ENG PRE APRON ¤30.00 01/23/2023
SW ENG - REVIEW 20 ¤20.00 01/23/2023
SW ENG RES REVIEW 200 ¤200.00 01/23/2023
TRANS IMPACT FEE ADMIN ¤52.92 01/23/2023
TRANS IMPACT FEE ADMIN (¤52.92) 01/23/2023
SEWER CREDIT (¤850.00) 01/23/2023
SEWER INSPECTION ¤25.00 01/23/2023
SEWER CAPITAL FACILITY ¤5,344.82 01/23/2023
WATER CAPITAL FACILITY FEE ¤3,923.88 01/23/2023
SITE PLAN 30 ¤30.00 01/23/2023
CONNECTION FEES ¤1,166.26 01/23/2023
WATER- TURN ON ¤25.00 01/23/2023
ADJUSTMENT 50% (¤438.60) 01/23/2023
ADMINISTRATIVE RESIDENTIAL ¤30.00 01/23/2023
INSPECTION - RESIDENTIAL ¤660.00 01/23/2023
PLAN REVIEW - RESIDENTIAL ¤187.20 01/23/2023
Fees Total Due: ¤0.00 Total Paid: ¤20,852.45