Permit #2022120994

Permit Details

Status: COED

Parcel Id: 07-11-31-7029-00720-0030
CONDITIONED SPACE: 1517 sqft
GARAGE: 394 sqft
Total Square Footage: 1911 sqft
Block: 00720
Subdivision: 2209 - SECTION 29-ROYAL PALMS
Job Phone: 470-817-1259
Location Address: 46 RYMER LN
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 01/23/2023
NOC: RECORDED
Applicant name: WADE GILMER JURNEY JR
Owner: NATIONAL HOME CORP

Address

1080 HOLCOMB BRIDGE RD 100-330

ROSWELL , GA 30076

Lot: 0030
Contracted Stated Job Value: ¤209,353.00
Job Description: Single Family Residence
Type: CN

Contractor

NATIONAL HOME CORPORATION
Status Location Address Mailing Address State License Number Phone
INACTIVE

1080 HOLCOMB BRIDGE ROAD

,

BLDG 100 - 330

ROSWELL , GA 30076

CBC1257700 (Exp: 08/31/2026) 471-817-1259

Sub Contractors

RANDALL SCOTT ROSENFELD
Status Location Address State License Number Phone
ACTIVE

234 N WHITNEY ST

PALM COAST, FL 32084

CAC1816641 (Exp: 08/31/2026) 904-599-0082
DUSTIN L ESTEP
Status Location Address State License Number Phone Fax
ACTIVE

2041 N HIAWASSEE RD

APOPKA, FL 32703

CCC1330971 (Exp: 08/31/2026) 407-702-0206 352-988-6629
JASON PATRICK RIBOCK
Status Location Address State License Number Phone
INACTIVE

620 E PINE ST

, 0

ES12001313 (Exp: 08/31/2026) 407-625-0257
PAUL ERIC FORSTER
Status Location Address State License Number Phone
ACTIVE

6114 GOODMAN RD

JACKSONVILLE, FL 32244

CFC1429261 (Exp: 08/31/2026) 904-647-1820

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 12/28/2023 FINAL APPROVED JWALKER
Note: 12/27/2023 - PREVIOUS INSPECTION NOTES 1. The energy calculations do not match the AHU and the heatpump installed. Please submit a revision to the building department for the change of appliances. 2. The AHU / water heater closet walls where the pipes penetrate the wall will need to be sealed due to the closet being used as the return plenum.
BLD - BUILDING FINAL 12/27/2023 Disapproved - NO FEE JWALKER
Note: 1. The energy calculations do not match the AHU and the heatpump installed. Please submit a revision to the building department for the change of appliances. 2. The AHU / water heater closet walls where the pipes penetrate the wall will need to be sealed due to the closet being used as the return plenum.
U -UTILITY RESIDENTIAL FINAL 12/27/2023 FINAL APPROVED DHANEY
Note: Inspector Notes from Inspection 9035 no irrigation-no cross connection
ROW - STORMWATER FINAL 12/22/2023 APPROVED TPOLACEK
Note: 12/22/23 AT THE TIME FROM THE TIME OF THE INSPECTION OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED.
ROW - FINAL APRON (AFTER POUR) 12/22/2023 APPROVED TPOLACEK
Note: 12/22/23 CORRECTION WERE MADE AT THE TIME FROM THE TIME OF THE INSPECTION OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. 12/21/2023 - PREVIOUS INSPECTION NOTES 12/21/23 PIPE IS GOOD. CUTS ARE MADE, CULVERT CLEAR. HOT PATCH COMPLETE. HOWEVER THE SWALE ON THE RIGHT SIDE PROPERTY LINE DOES NOT MATCH EXISTING GRADE. THIS NEEDS TO BE CORRECTED. NO FEE THIS TIME Inspector Notes from Inspection 9465 12/21/23 RIGHT ISDE PROPERTY LINE MST MEET EXISTING GRADE. SOD DOES NOT MATCH. I WILL APPROVE ON THE FIELD AS A COURTESY THIS TIME BUT DISAPPROVE ON THE AFTER POUR UNTIL SOD IS MATCHED. ______________________________________________________________________________________________ 11/30/2023 - PREVIOUS INSPECTION NOTES THIS INSPECTION IS AFTER THE FINAL SURVEY HAS PASSED. NEED TO REVISE FINAL SURVEY WITH ALL THE CORRECTION NEEDED TO PASS. ---------------------------------------------------------------------------- 11/27/2023 - PREVIOUS INSPECTION NOTES THIS INSPECTION IS AFTER THE FINAL SURVEY HAS PASSED. NEED TO REVISE FINAL SURVEY WITH ALL THE CORRECTION NEEDED TO PASS. ------------------------------------------------------------------- 11/1/2023 - PREVIOUS INSPECTION NOTES 11/1/23= The tolerance alongside lot lines is no more than 20 feet flat, with a positive fall on each side. Positive fall is considered to be 0.10 feet in 20 feet. The minimum fall from the rear property line to the front is 0.50 feet. Sec 300.01(4,5,6) YOU CANNOT DUMP STORMWATER IN THE LOT BEHIND YOUR PROPERTY; INSTEAD, BRING IT TO THE FRONT. Unless specifically stated the subject lot must drain from back to front or a portion may be drained to an adjacent City drainage feature. (B)B.Land Development Code Technical Manual, Section 300.01 (A)(1)(C)(6) The subject lots drainage must not negatively impact any adjacent property. (B)
ROW- FINAL SURVEY/GRADING CERTIFICATION 12/21/2023 APPROVED TPOLACEK
Note: 12/21/23 UPON WALKING PROPERTY DRAINAGE WILL WORK AS INDICATED ON FINAL SURVEY. AT THE TIME FROM THE TIME OF THE INSPECTION OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. ________________________________________________________________________________________________ 12/14/2023 - PREVIOUS INSPECTION NOTES THE FINAL SURVEY SHOWS THE WATER STILL IMPACTING THE LOT TO THE BACK LEFT THATS IMPROVED. NEED TO REGRADE SO WATER WILL NOT IMPACT IT. IN THE FIELD IT VERIFYS THE FINAL SURVEY THAT IT IS IMPACTING IT. --------------------------------------------------------------------------- 11/30/2023 - PREVIOUS INSPECTION NOTES THE FINAL SURVEY STILL STATES THAT YOUR DRAINAGE IS IMPACTING THE LOT TO THE BACK OF YOURS. WENT OUT TO LOOK AT THE GRADE AND I CANT TELL IF THE GRADE DOES IMPACT BECAUSE THE DRAINAGE IS FLAT NEED TO RAISE THE BACK PROPERTY LINE MORE SO THE GRADE IS MORE OBVIOUS. ----------------------------------------------------------------------- 11/15/2023 - PREVIOUS INSPECTION NOTES 1) STILL NEED TO BRING ALL WATER FROM BACK TO THE FRONT WATER IS IMPACTING THE LOT BEHIND YOURS. Section 300.01 (A)(1)(C)(6). Unless specifically stated the subject lot must drain from back to front. Section 300.01 (A)(1)(C)(6). The subject lots drainage must not negatively impact any adjacent property. 2) ALL RIGHT OF WAY ELEVATIONS NEED TO BE EQUAL OR HIGHER THAN THE CENTERLINE OF THE ROAD SO WATER WILL NOT BACK UP INTO THE LOT DURING BIG RAIN EVENTS. Drawing 300.D,The front property line/right away elevation are to be equal to or greater than the centerline of the road elevation. ------------------------------------------------------------------------------------- 11/1/23= The tolerance alongside lot lines is no more than 20 feet flat, with a positive fall on each side. Positive fall is considered to be 0.10 feet in 20 feet. The minimum fall from the rear property line to the front is 0.50 feet. Sec 300.01(4,5,6) YOU CANNOT DUMP STORMWATER IN THE LOT BEHIND YOUR PROPERTY; INSTEAD, BRING IT TO THE FRONT. Unless specifically stated the subject lot must drain from back to front or a portion may be drained to an adjacent City drainage feature. (B)B.Land Development Code Technical Manual, Section 300.01 (A)(1)(C)(6) The subject lots drainage must not negatively impact any adjacent property. (B)
ROW FIELD SURVEY /GRADING CERTIFICATION 12/21/2023 APPROVED - AS NOTED TPOLACEK
Note: 12/21/23 RIGHT ISDE PROPERTY LINE MST MEET EXISTING GRADE. SOD DOES NOT MATCH. I WILL APPROVE ON THE FIELD AS A COURTESY THIS TIME BUT DISAPPROVE ON THE AFTER POUR UNTIL SOD IS MATCHED. ______________________________________________________________________________________________ 11/30/2023 - PREVIOUS INSPECTION NOTES THIS INSPECTION IS AFTER THE FINAL SURVEY HAS PASSED. NEED TO REVISE FINAL SURVEY WITH ALL THE CORRECTION NEEDED TO PASS. ---------------------------------------------------------------------------- 11/27/2023 - PREVIOUS INSPECTION NOTES THIS INSPECTION IS AFTER THE FINAL SURVEY HAS PASSED. NEED TO REVISE FINAL SURVEY WITH ALL THE CORRECTION NEEDED TO PASS. ------------------------------------------------------------------- 11/1/2023 - PREVIOUS INSPECTION NOTES 11/1/23= The tolerance alongside lot lines is no more than 20 feet flat, with a positive fall on each side. Positive fall is considered to be 0.10 feet in 20 feet. The minimum fall from the rear property line to the front is 0.50 feet. Sec 300.01(4,5,6) YOU CANNOT DUMP STORMWATER IN THE LOT BEHIND YOUR PROPERTY; INSTEAD, BRING IT TO THE FRONT. Unless specifically stated the subject lot must drain from back to front or a portion may be drained to an adjacent City drainage feature. (B)B.Land Development Code Technical Manual, Section 300.01 (A)(1)(C)(6) The subject lots drainage must not negatively impact any adjacent property. (B)
ROW - FINAL APRON (AFTER POUR) 12/21/2023 Disapproved - NO FEE TPOLACEK
Note: 12/21/23 PIPE IS GOOD. CUTS ARE MADE, CULVERT CLEAR. HOT PATCH COMPLETE. HOWEVER THE SWALE ON THE RIGHT SIDE PROPERTY LINE DOES NOT MATCH EXISTING GRADE. THIS NEEDS TO BE CORRECTED. NO FEE THIS TIME Inspector Notes from Inspection 9465 12/21/23 RIGHT ISDE PROPERTY LINE MST MEET EXISTING GRADE. SOD DOES NOT MATCH. I WILL APPROVE ON THE FIELD AS A COURTESY THIS TIME BUT DISAPPROVE ON THE AFTER POUR UNTIL SOD IS MATCHED. ______________________________________________________________________________________________ 11/30/2023 - PREVIOUS INSPECTION NOTES THIS INSPECTION IS AFTER THE FINAL SURVEY HAS PASSED. NEED TO REVISE FINAL SURVEY WITH ALL THE CORRECTION NEEDED TO PASS. ---------------------------------------------------------------------------- 11/27/2023 - PREVIOUS INSPECTION NOTES THIS INSPECTION IS AFTER THE FINAL SURVEY HAS PASSED. NEED TO REVISE FINAL SURVEY WITH ALL THE CORRECTION NEEDED TO PASS. ------------------------------------------------------------------- 11/1/2023 - PREVIOUS INSPECTION NOTES 11/1/23= The tolerance alongside lot lines is no more than 20 feet flat, with a positive fall on each side. Positive fall is considered to be 0.10 feet in 20 feet. The minimum fall from the rear property line to the front is 0.50 feet. Sec 300.01(4,5,6) YOU CANNOT DUMP STORMWATER IN THE LOT BEHIND YOUR PROPERTY; INSTEAD, BRING IT TO THE FRONT. Unless specifically stated the subject lot must drain from back to front or a portion may be drained to an adjacent City drainage feature. (B)B.Land Development Code Technical Manual, Section 300.01 (A)(1)(C)(6) The subject lots drainage must not negatively impact any adjacent property. (B)
ROW- FINAL SURVEY/GRADING CERTIFICATION 12/14/2023 Disapproved -FEE REQUIRED PFLANAGAN
Note: THE FINAL SURVEY SHOWS THE WATER STILL IMPACTING THE LOT TO THE BACK LEFT THATS IMPROVED. NEED TO REGRADE SO WATER WILL NOT IMPACT IT. IN THE FIELD IT VERIFYS THE FINAL SURVEY THAT IT IS IMPACTING IT. --------------------------------------------------------------------------- 11/30/2023 - PREVIOUS INSPECTION NOTES THE FINAL SURVEY STILL STATES THAT YOUR DRAINAGE IS IMPACTING THE LOT TO THE BACK OF YOURS. WENT OUT TO LOOK AT THE GRADE AND I CANT TELL IF THE GRADE DOES IMPACT BECAUSE THE DRAINAGE IS FLAT NEED TO RAISE THE BACK PROPERTY LINE MORE SO THE GRADE IS MORE OBVIOUS. ----------------------------------------------------------------------- 11/15/2023 - PREVIOUS INSPECTION NOTES 1) STILL NEED TO BRING ALL WATER FROM BACK TO THE FRONT WATER IS IMPACTING THE LOT BEHIND YOURS. Section 300.01 (A)(1)(C)(6). Unless specifically stated the subject lot must drain from back to front. Section 300.01 (A)(1)(C)(6). The subject lots drainage must not negatively impact any adjacent property. 2) ALL RIGHT OF WAY ELEVATIONS NEED TO BE EQUAL OR HIGHER THAN THE CENTERLINE OF THE ROAD SO WATER WILL NOT BACK UP INTO THE LOT DURING BIG RAIN EVENTS. Drawing 300.D,The front property line/right away elevation are to be equal to or greater than the centerline of the road elevation. ------------------------------------------------------------------------------------- 11/1/23= The tolerance alongside lot lines is no more than 20 feet flat, with a positive fall on each side. Positive fall is considered to be 0.10 feet in 20 feet. The minimum fall from the rear property line to the front is 0.50 feet. Sec 300.01(4,5,6) YOU CANNOT DUMP STORMWATER IN THE LOT BEHIND YOUR PROPERTY; INSTEAD, BRING IT TO THE FRONT. Unless specifically stated the subject lot must drain from back to front or a portion may be drained to an adjacent City drainage feature. (B)B.Land Development Code Technical Manual, Section 300.01 (A)(1)(C)(6) The subject lots drainage must not negatively impact any adjacent property. (B)
ELECTRIC-TUG 12/07/2023 APPROVED JWALKER
Note: 8/10/2023 - PREVIOUS INSPECTION NOTES No Tug. Contractor needs to schedule an early power. Note to contractor Home is not ready for early power.
ROW- FINAL SURVEY/GRADING CERTIFICATION 11/30/2023 Disapproved -FEE REQUIRED PFLANAGAN
Note: THE FINAL SURVEY STILL STATES THAT YOUR DRAINAGE IS IMPACTING THE LOT TO THE BACK OF YOURS. WENT OUT TO LOOK AT THE GRADE AND I CANT TELL IF THE GRADE DOES IMPACT BECAUSE THE DRAINAGE IS FLAT NEED TO RAISE THE BACK PROPERTY LINE MORE SO THE GRADE IS MORE OBVIOUS. ----------------------------------------------------------------------- 11/15/2023 - PREVIOUS INSPECTION NOTES 1) STILL NEED TO BRING ALL WATER FROM BACK TO THE FRONT WATER IS IMPACTING THE LOT BEHIND YOURS. Section 300.01 (A)(1)(C)(6). Unless specifically stated the subject lot must drain from back to front. Section 300.01 (A)(1)(C)(6). The subject lots drainage must not negatively impact any adjacent property. 2) ALL RIGHT OF WAY ELEVATIONS NEED TO BE EQUAL OR HIGHER THAN THE CENTERLINE OF THE ROAD SO WATER WILL NOT BACK UP INTO THE LOT DURING BIG RAIN EVENTS. Drawing 300.D,The front property line/right away elevation are to be equal to or greater than the centerline of the road elevation. ------------------------------------------------------------------------------------- 11/1/23= The tolerance alongside lot lines is no more than 20 feet flat, with a positive fall on each side. Positive fall is considered to be 0.10 feet in 20 feet. The minimum fall from the rear property line to the front is 0.50 feet. Sec 300.01(4,5,6) YOU CANNOT DUMP STORMWATER IN THE LOT BEHIND YOUR PROPERTY; INSTEAD, BRING IT TO THE FRONT. Unless specifically stated the subject lot must drain from back to front or a portion may be drained to an adjacent City drainage feature. (B)B.Land Development Code Technical Manual, Section 300.01 (A)(1)(C)(6) The subject lots drainage must not negatively impact any adjacent property. (B)
ROW FIELD SURVEY /GRADING CERTIFICATION 11/30/2023 Disapproved - NO FEE PFLANAGAN
Note: THIS INSPECTION IS AFTER THE FINAL SURVEY HAS PASSED. NEED TO REVISE FINAL SURVEY WITH ALL THE CORRECTION NEEDED TO PASS. ---------------------------------------------------------------------------- 11/27/2023 - PREVIOUS INSPECTION NOTES THIS INSPECTION IS AFTER THE FINAL SURVEY HAS PASSED. NEED TO REVISE FINAL SURVEY WITH ALL THE CORRECTION NEEDED TO PASS. ------------------------------------------------------------------- 11/1/2023 - PREVIOUS INSPECTION NOTES 11/1/23= The tolerance alongside lot lines is no more than 20 feet flat, with a positive fall on each side. Positive fall is considered to be 0.10 feet in 20 feet. The minimum fall from the rear property line to the front is 0.50 feet. Sec 300.01(4,5,6) YOU CANNOT DUMP STORMWATER IN THE LOT BEHIND YOUR PROPERTY; INSTEAD, BRING IT TO THE FRONT. Unless specifically stated the subject lot must drain from back to front or a portion may be drained to an adjacent City drainage feature. (B)B.Land Development Code Technical Manual, Section 300.01 (A)(1)(C)(6) The subject lots drainage must not negatively impact any adjacent property. (B)
ROW FIELD SURVEY /GRADING CERTIFICATION 11/27/2023 Disapproved -FEE REQUIRED PFLANAGAN
Note: THIS INSPECTION IS AFTER THE FINAL SURVEY HAS PASSED. NEED TO REVISE FINAL SURVEY WITH ALL THE CORRECTION NEEDED TO PASS. ------------------------------------------------------------------- 11/1/2023 - PREVIOUS INSPECTION NOTES 11/1/23= The tolerance alongside lot lines is no more than 20 feet flat, with a positive fall on each side. Positive fall is considered to be 0.10 feet in 20 feet. The minimum fall from the rear property line to the front is 0.50 feet. Sec 300.01(4,5,6) YOU CANNOT DUMP STORMWATER IN THE LOT BEHIND YOUR PROPERTY; INSTEAD, BRING IT TO THE FRONT. Unless specifically stated the subject lot must drain from back to front or a portion may be drained to an adjacent City drainage feature. (B)B.Land Development Code Technical Manual, Section 300.01 (A)(1)(C)(6) The subject lots drainage must not negatively impact any adjacent property. (B)
ROW- FINAL SURVEY/GRADING CERTIFICATION 11/15/2023 Disapproved -FEE REQUIRED PFLANAGAN
Note: 1) STILL NEED TO BRING ALL WATER FROM BACK TO THE FRONT WATER IS IMPACTING THE LOT BEHIND YOURS. Section 300.01 (A)(1)(C)(6). Unless specifically stated the subject lot must drain from back to front. Section 300.01 (A)(1)(C)(6). The subject lots drainage must not negatively impact any adjacent property. 2) ALL RIGHT OF WAY ELEVATIONS NEED TO BE EQUAL OR HIGHER THAN THE CENTERLINE OF THE ROAD SO WATER WILL NOT BACK UP INTO THE LOT DURING BIG RAIN EVENTS. Drawing 300.D,The front property line/right away elevation are to be equal to or greater than the centerline of the road elevation. ------------------------------------------------------------------------------------- 11/1/23= The tolerance alongside lot lines is no more than 20 feet flat, with a positive fall on each side. Positive fall is considered to be 0.10 feet in 20 feet. The minimum fall from the rear property line to the front is 0.50 feet. Sec 300.01(4,5,6) YOU CANNOT DUMP STORMWATER IN THE LOT BEHIND YOUR PROPERTY; INSTEAD, BRING IT TO THE FRONT. Unless specifically stated the subject lot must drain from back to front or a portion may be drained to an adjacent City drainage feature. (B)B.Land Development Code Technical Manual, Section 300.01 (A)(1)(C)(6) The subject lots drainage must not negatively impact any adjacent property. (B)
ROW- FINAL SURVEY/GRADING CERTIFICATION 11/01/2023 Disapproved - NO FEE GBERTOLA
Note: 11/1/23= The tolerance alongside lot lines is no more than 20 feet flat, with a positive fall on each side. Positive fall is considered to be 0.10 feet in 20 feet. The minimum fall from the rear property line to the front is 0.50 feet. Sec 300.01(4,5,6) YOU CANNOT DUMP STORMWATER IN THE LOT BEHIND YOUR PROPERTY; INSTEAD, BRING IT TO THE FRONT. Unless specifically stated the subject lot must drain from back to front or a portion may be drained to an adjacent City drainage feature. (B)B.Land Development Code Technical Manual, Section 300.01 (A)(1)(C)(6) The subject lots drainage must not negatively impact any adjacent property. (B)
ROW FIELD SURVEY /GRADING CERTIFICATION 11/01/2023 Disapproved - NO FEE GBERTOLA
Note: 11/1/23= The tolerance alongside lot lines is no more than 20 feet flat, with a positive fall on each side. Positive fall is considered to be 0.10 feet in 20 feet. The minimum fall from the rear property line to the front is 0.50 feet. Sec 300.01(4,5,6) YOU CANNOT DUMP STORMWATER IN THE LOT BEHIND YOUR PROPERTY; INSTEAD, BRING IT TO THE FRONT. Unless specifically stated the subject lot must drain from back to front or a portion may be drained to an adjacent City drainage feature. (B)B.Land Development Code Technical Manual, Section 300.01 (A)(1)(C)(6) The subject lots drainage must not negatively impact any adjacent property. (B)
ROW- PRE-APRON (PRE-POUR) 09/19/2023 APPROVED - AS NOTED FSLADISH
Note: 09/19/23 YOU NEED TO MAKE SURE YOUR MITERED END FOOTERS ARE DUG OUT TO CITY SPECIFICATIONS OF 6" X 6" BEFORE YOU POUR. IT IS THE BUILDERS REPOSIBILITY TO MAKE SURE ELEVATIONS ARE CORRECT BEFORE POURING. At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved. This includes but is not limited to, the Culvert Pipe Elevation from the time of the inspection approval to the concrete pour. AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS BEFORE POURING. MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL 9/14/2023 - PREVIOUS INSPECTION NOTES 9/8/2023 - PREVIOUS INSPECTION NOTES 1) STILL NEED TO DIG OUT THE FOOTER TO MINIMUM OF 6"X6" 2) SINCE IT BEEN A LITTLE BIT FROM LAST PRE POUR INSPECTION NOW THERE IS GRASS GROWING IN THE POURING AREA NEED TO REMOVE ALL ORGANIC MATERIAL 3) NEED TO HAVE 6" OF CONCRETE IN RIGHT OF WAY AND 4" ABOVE THE RIGHT OF WAY ---------------------------------------------------------------------------------- 8/24/2023 - PREVIOUS INSPECTION NOTES 1) NEED TO HAVE 6" OF CONCRETE IN RIGHT OF WAY AND 4" ABOVE THE RIGHT OF WAY 2) THE FOOTERS AT THE MITER ENDS STILL NEED TO BE A MINIMUM OF 6"X6" -------------------------------------------------------------------------------------------- 8/21/2023 - PREVIOUS INSPECTION NOTES 1) THE CULVERT IS PITCHED TO MUCH ONLY ALLOWED .10 FALL 2) NEED TO HAVE THE MITER END FOOTER A MINIMUM OF 6"X6" -------------------------------------------------------------------------------------------------- 8/15/2023 - PREVIOUS INSPECTION NOTES SEC300 (E) (1) The construction site must have the address clearly displayed and the Builders Box must include the following documents before an inspection will be conducted ------------------------------------------------------------------------------------------------------------- 8/10/2023 - PREVIOUS INSPECTION NOTES 08/10/23 TOO WET TO POUR. PLEASE SEE PHOTO FOR REFERENCE. PIPE OK AT THE TIME OF THIS INSPECTION, BUT DOESN'T MEAN IT WILL BE NEXT INSPECTION.
U-CROSS CONNECTION 09/19/2023 APPROVED - AS NOTED LFITZGERALD
Note: no irrigation-no cross connection
ROW- PRE-APRON (PRE-POUR) 09/14/2023 CANCELLED BY APPLICANT FSLADISH
Note: 9/8/2023 - PREVIOUS INSPECTION NOTES 1) STILL NEED TO DIG OUT THE FOOTER TO MINIMUM OF 6"X6" 2) SINCE IT BEEN A LITTLE BIT FROM LAST PRE POUR INSPECTION NOW THERE IS GRASS GROWING IN THE POURING AREA NEED TO REMOVE ALL ORGANIC MATERIAL 3) NEED TO HAVE 6" OF CONCRETE IN RIGHT OF WAY AND 4" ABOVE THE RIGHT OF WAY ---------------------------------------------------------------------------------- 8/24/2023 - PREVIOUS INSPECTION NOTES 1) NEED TO HAVE 6" OF CONCRETE IN RIGHT OF WAY AND 4" ABOVE THE RIGHT OF WAY 2) THE FOOTERS AT THE MITER ENDS STILL NEED TO BE A MINIMUM OF 6"X6" -------------------------------------------------------------------------------------------- 8/21/2023 - PREVIOUS INSPECTION NOTES 1) THE CULVERT IS PITCHED TO MUCH ONLY ALLOWED .10 FALL 2) NEED TO HAVE THE MITER END FOOTER A MINIMUM OF 6"X6" -------------------------------------------------------------------------------------------------- 8/15/2023 - PREVIOUS INSPECTION NOTES SEC300 (E) (1) The construction site must have the address clearly displayed and the Builders Box must include the following documents before an inspection will be conducted ------------------------------------------------------------------------------------------------------------- 8/10/2023 - PREVIOUS INSPECTION NOTES 08/10/23 TOO WET TO POUR. PLEASE SEE PHOTO FOR REFERENCE. PIPE OK AT THE TIME OF THIS INSPECTION, BUT DOESN'T MEAN IT WILL BE NEXT INSPECTION.
ROW- PRE-APRON (PRE-POUR) 09/08/2023 Disapproved -FEE REQUIRED PFLANAGAN
Note: 1) STILL NEED TO DIG OUT THE FOOTER TO MINIMUM OF 6"X6" 2) SINCE IT BEEN A LITTLE BIT FROM LAST PRE POUR INSPECTION NOW THERE IS GRASS GROWING IN THE POURING AREA NEED TO REMOVE ALL ORGANIC MATERIAL 3) NEED TO HAVE 6" OF CONCRETE IN RIGHT OF WAY AND 4" ABOVE THE RIGHT OF WAY ---------------------------------------------------------------------------------- 8/24/2023 - PREVIOUS INSPECTION NOTES 1) NEED TO HAVE 6" OF CONCRETE IN RIGHT OF WAY AND 4" ABOVE THE RIGHT OF WAY 2) THE FOOTERS AT THE MITER ENDS STILL NEED TO BE A MINIMUM OF 6"X6" -------------------------------------------------------------------------------------------- 8/21/2023 - PREVIOUS INSPECTION NOTES 1) THE CULVERT IS PITCHED TO MUCH ONLY ALLOWED .10 FALL 2) NEED TO HAVE THE MITER END FOOTER A MINIMUM OF 6"X6" -------------------------------------------------------------------------------------------------- 8/15/2023 - PREVIOUS INSPECTION NOTES SEC300 (E) (1) The construction site must have the address clearly displayed and the Builders Box must include the following documents before an inspection will be conducted ------------------------------------------------------------------------------------------------------------- 8/10/2023 - PREVIOUS INSPECTION NOTES 08/10/23 TOO WET TO POUR. PLEASE SEE PHOTO FOR REFERENCE. PIPE OK AT THE TIME OF THIS INSPECTION, BUT DOESN'T MEAN IT WILL BE NEXT INSPECTION.
ROW- PRE-APRON (PRE-POUR) 08/24/2023 Disapproved -FEE REQUIRED PFLANAGAN
Note: 1) NEED TO HAVE 6" OF CONCRETE IN RIGHT OF WAY AND 4" ABOVE THE RIGHT OF WAY 2) THE FOOTERS AT THE MITER ENDS STILL NEED TO BE A MINIMUM OF 6"X6" -------------------------------------------------------------------------------------------- 8/21/2023 - PREVIOUS INSPECTION NOTES 1) THE CULVERT IS PITCHED TO MUCH ONLY ALLOWED .10 FALL 2) NEED TO HAVE THE MITER END FOOTER A MINIMUM OF 6"X6" -------------------------------------------------------------------------------------------------- 8/15/2023 - PREVIOUS INSPECTION NOTES SEC300 (E) (1) The construction site must have the address clearly displayed and the Builders Box must include the following documents before an inspection will be conducted ------------------------------------------------------------------------------------------------------------- 8/10/2023 - PREVIOUS INSPECTION NOTES 08/10/23 TOO WET TO POUR. PLEASE SEE PHOTO FOR REFERENCE. PIPE OK AT THE TIME OF THIS INSPECTION, BUT DOESN'T MEAN IT WILL BE NEXT INSPECTION.
ELECTRIC - EARLY POWER 08/22/2023 APPROVED JWALKER
Note: 8/11/2023 - PREVIOUS INSPECTION NOTES Main electrical panel cover has not been installed.
ROW- PRE-APRON (PRE-POUR) 08/21/2023 Disapproved -FEE REQUIRED PFLANAGAN
Note: 1) THE CULVERT IS PITCHED TO MUCH ONLY ALLOWED .10 FALL 2) NEED TO HAVE THE MITER END FOOTER A MINIMUM OF 6"X6" -------------------------------------------------------------------------------------------------- 8/15/2023 - PREVIOUS INSPECTION NOTES SEC300 (E) (1) The construction site must have the address clearly displayed and the Builders Box must include the following documents before an inspection will be conducted ------------------------------------------------------------------------------------------------------------- 8/10/2023 - PREVIOUS INSPECTION NOTES 08/10/23 TOO WET TO POUR. PLEASE SEE PHOTO FOR REFERENCE. PIPE OK AT THE TIME OF THIS INSPECTION, BUT DOESN'T MEAN IT WILL BE NEXT INSPECTION.
ROW- PRE-APRON (PRE-POUR) 08/15/2023 Disapproved -FEE REQUIRED PFLANAGAN
Note: SEC300 (E) (1) The construction site must have the address clearly displayed and the Builders Box must include the following documents before an inspection will be conducted ------------------------------------------------------------------------------------------------------------- 8/10/2023 - PREVIOUS INSPECTION NOTES 08/10/23 TOO WET TO POUR. PLEASE SEE PHOTO FOR REFERENCE. PIPE OK AT THE TIME OF THIS INSPECTION, BUT DOESN'T MEAN IT WILL BE NEXT INSPECTION.
GRAVITY SEWER TEST 08/11/2023 APPROVED - AS NOTED MGIBSON
Note: THIS WAS A VIRTUAL INSPECTION
ELECTRIC - EARLY POWER 08/11/2023 Disapproved - NO FEE JWALKER
Note: Main electrical panel cover has not been installed.
U - SEWER TIE IN 08/11/2023 APPROVED - AS NOTED MGIBSON
Note: THIS WAS A VIRTUAL INSPECTION
ELECTRIC-TUG 08/10/2023 Disapproved - NO FEE JWALKER
Note: No Tug. Contractor needs to schedule an early power. Note to contractor Home is not ready for early power.
ROW- PRE-APRON (PRE-POUR) 08/10/2023 Disapproved -FEE REQUIRED FSLADISH
Note: 08/10/23 TOO WET TO POUR. PLEASE SEE PHOTO FOR REFERENCE. PIPE OK AT THE TIME OF THIS INSPECTION, BUT DOESN'T MEAN IT WILL BE NEXT INSPECTION.
PEP TANK INSTALLATION REQUEST 07/05/2023 APPROVED CSTONE
INSULATION 06/23/2023 APPROVED BTAYLOR
Note: 6/20/2023 - PREVIOUS INSPECTION NOTES All windows and doors have not been sealed between the window and the jambs. / Spray foamed.
INSULATION 06/20/2023 Disapproved - NO FEE JWALKER
Note: All windows and doors have not been sealed between the window and the jambs. / Spray foamed.
ALL ROUGH 06/09/2023 APPROVED JWALKER
Note: 5/24/2023 - PREVIOUS INSPECTION NOTES 1. The smoke detector in the hallway needs to be a minimum of 3' from the HVAC supply 2. 12-2 wire and 10-3 wire in the laundry room have not been terminated into outlet boxes. 3. The bath room fan duct need a proper reducer connection for the 4" duct into the 3" fan. 4. No pressure reading at the water distribution lines. 5. The spray foam used to seal the top plates and the top of the electrical panel is to be of the fire foam type. 6. All flex duct is to be supported a minimum of 4' o.c. to prevent sagging.
LATH/BRICK/ WATER BARRIER 06/05/2023 APPROVED JWALKER
ALL ROUGH 05/24/2023 Disapproved - NO FEE JWALKER
Note: 1. The smoke detector in the hallway needs to be a minimum of 3' from the HVAC supply 2. 12-2 wire and 10-3 wire in the laundry room have not been terminated into outlet boxes. 3. The bath room fan duct need a proper reducer connection for the 4" duct into the 3" fan. 4. No pressure reading at the water distribution lines. 5. The spray foam used to seal the top plates and the top of the electrical panel is to be of the fire foam type. 6. All flex duct is to be supported a minimum of 4' o.c. to prevent sagging.
ALL ROUGH 05/15/2023 CANCELLED BY APPLICANT RSIMS
Note: 5/15/23: Cancelled by applicant via verbally. Stated not ready.
WALL SHEATHING 04/26/2023 APPROVED FWILLIS
ROOF SHEATHING / BRACES/TIES/DOWN CELL 04/26/2023 APPROVED FWILLIS
ROOF SHEATHING 04/26/2023 APPROVED FWILLIS
ROOF VALLEY & METAL 04/26/2023 APPROVED FWILLIS
FOUND SURVEY APPROVED (OFFICE) 04/20/2023 APPROVED TBAKER
TIE BEAM / LINTEL 03/27/2023 APPROVED JWALKER
MONOLITHIC SLAB 03/17/2023 APPROVED FWILLIS
Note: 3/16/2023 - PREVIOUS INSPECTION NOTES The set of prints are not the required approved set and are from 4 rickenbacker. Please have a full set of approved prints that are site specific for inspections
MONOLITHIC SLAB 03/16/2023 Disapproved -FEE REQUIRED JWALKER
Note: The set of prints are not the required approved set and are from 4 rickenbacker. Please have a full set of approved prints that are site specific for inspections
PLUMBING 1ST ROUGH UNDERGROUND 03/10/2023 APPROVED MGIBSON
WATER METER INSTALLATION REQUEST 02/06/2023 APPROVED TSCHWEERS

Review History

Department Status Date In Date Out
BADMIN INFORMATION 12/19/2023 12/19/2023
Note: Marked INFORMATION By: BARBIE BEMBRY - (386)986-3780 - BUILDINGDIVISION@PALMCOASTGOV.COM Documents/Files named incorrectly o Please rename your files in accordance with the naming convention outlined in our ‘document requirements’ located on the permit portal page http://docs.palmcoastgov.com/departments/building/online/document-requirements.pdf o It is important that all submittals follow the guidelines for efficient plan review and record retention accuracy. o You may add to your file name AFTER the above naming convention has been met. Examples Document type: Plans File name : Plans Document type: Foundation Survey File name: Foundation Survey Document type: Manufactures Specifications File Name: Pool Alarm Document type: Manufactures Specifications File Name: Generator
BADMIN INFORMATION 10/31/2023 10/31/2023
Note: Marked INFORMATION By: BARBIE BEMBRY - (386)986-3780 - BUILDINGDIVISION@PALMCOASTGOV.COM Please rename your file (remove anything from in front of 'final survey' )
ENGIN1 COMPLETE 04/20/2023 04/20/2023
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON COMPLETE 04/20/2023 04/20/2023
Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM
MECH COMPLETE 02/08/2023 02/09/2023
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
MECH HOLD 02/02/2023 02/03/2023
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Duct layout needs to be signed by the AC contractor per 107.1 FBC Residential 2020 7th Edition
MECH COMPLETE 01/06/2023 01/06/2023
Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM
ZON COMPLETE 01/06/2023 01/06/2023
Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM
SWALE COMPLETE 12/28/2022 04/10/2023
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
BLD COMPLETE 12/27/2022 12/28/2022
Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM
CUSVC COMPLETE 12/27/2022 12/29/2022
Note: Released By: HALEIGH HAND - -
ELEC COMPLETE 12/27/2022 12/28/2022
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ENGIN1 COMPLETE 12/27/2022 12/28/2022
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
LOCATE COMPLETE 12/27/2022 12/28/2022
Note: Released By: CANDACE STONE - - CSTONE@PALMCOASTGOV.COM
MECH HOLD 12/27/2022 12/28/2022
Note: Held By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM All comments below per the 2020 Florida Building Code – Plumbing REVIEW COMMENTS: 1. Design location on Energy Forms is to be Daytona Beach. 2. Form 405 is to be signed by Owner/Agent
SW1 COMPLETE 12/27/2022 01/05/2023
Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM
ZON HOLD 12/27/2022 12/28/2022
Note: Held By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM Site plan: width of walkway Landscape: Please choose Shrubs for the foundation plantings that will be tolerant in our area this shrub Arboricola is also known as Dwarf Schefflera and is on the non credit planting list. Please look up the commonly used approved shrubs like Holly, vibumum, ligustrum those are tolerant in our area. Please list proposed sod and if it will need irrigation. A/C will need 7 gallon shrubs for screening

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
SW ENG REINSPECTION 20 ¤20.00 12/22/2023
SW ENG REINSPECTION 30 ¤30.00 12/22/2023
SW ENG REINSPECTION 30 ¤30.00 12/22/2023
SW ENG REINSPECTION 30 ¤30.00 12/22/2023
SW ENG REINSPECTION 30 ¤30.00 12/22/2023
SW ENG REINSPECTION 30 ¤30.00 12/22/2023
PLAN REVIEW - REVISION ¤32.50 04/13/2023
REINSPECTION RESIDENTIAL ¤40.00 04/13/2023
CONTRACTOR CHANGE ¤20.00 04/13/2023
FIRE IMPACT FEE ADMIN ¤12.92 01/23/2023
FIRE IMPACT FEE ADMIN (¤12.62) 01/23/2023
FC IMPACT FEE EMS ¤62.00 01/23/2023
IMPACT FEE FIRE ¤420.52 01/23/2023
FC IMPACT FEE LAW ENFORCEMENT ¤218.00 01/23/2023
FC IMPACT FEE LIBRARY ¤268.00 01/23/2023
IMPACT FEE PARKS ¤1,769.15 01/23/2023
IMPACT FEE SCHOOL ¤5,450.00 01/23/2023
IMPACT FEE TRANSPORTATION ¤1,764.00 01/23/2023
WATER -IRRIGATION INSPECTION ¤25.00 01/23/2023
PARKS IMPACT FEE ADMIN ¤53.07 01/23/2023
PARKS IMPACT FEE ADMIN (¤53.07) 01/23/2023
SURCHARGE FS 533.721 ¤2.58 01/23/2023
SURCHARGE - FS 468.631 ¤3.88 01/23/2023
SW ENG - FOUNDATION SURVEY ¤20.00 01/23/2023
SW ENG INSPECTION 80 ¤80.00 01/23/2023
SW ENG PRE APRON ¤30.00 01/23/2023
CONNECTION FEES ¤1,166.26 01/23/2023
WATER- TURN ON ¤25.00 01/23/2023
ADJUSTMENT 50% (¤385.65) 01/23/2023
ADMINISTRATIVE RESIDENTIAL ¤30.00 01/23/2023
INSPECTION - RESIDENTIAL ¤577.50 01/23/2023
PLAN REVIEW - RESIDENTIAL ¤163.80 01/23/2023
SW ENG - REVIEW 20 ¤20.00 01/23/2023
SW ENG RES REVIEW 200 ¤200.00 01/23/2023
TRANS IMPACT FEE ADMIN ¤52.92 01/23/2023
TRANS IMPACT FEE ADMIN (¤52.92) 01/23/2023
SEWER CREDIT (¤523.68) 01/23/2023
SEWER INSPECTION ¤25.00 01/23/2023
SEWER CAPITAL FACILITY ¤5,344.82 01/23/2023
WATER CAPITAL FACILITY FEE ¤3,923.88 01/23/2023
SITE PLAN 30 ¤30.00 01/23/2023
Fees Total Due: ¤0.00 Total Paid: ¤20,972.86