Permit #2022120996

Permit Details

Status: COED

Parcel Id: 07-11-31-7024-00450-0280
CONDITIONED SPACE: 1215 sqft
GARAGE: 396 sqft
Total Square Footage: 1611 sqft
Block: 00450
Subdivision: 2167 - SECTION 24-PINE GROVE
Job Phone: 470-817-1259
Location Address: 30 PRATTWOOD LN
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 01/23/2023
NOC: Unknown
Applicant name: WADE GILMER JURNEY JR
Owner: NATIONAL HOME CORP

Address

1080 HOLCOMB BRIDGE RD SUTIE 100-330

ROSWELL , GA 30076

Lot: 0280
Contracted Stated Job Value: ¤198,291.00
Job Description: Single Family Residence
Type: CN

Contractor

NATIONAL HOME CORPORATION
Status Location Address Mailing Address State License Number Phone
INACTIVE

1080 HOLCOMB BRIDGE ROAD

,

BLDG 100 - 330

ROSWELL , GA 30076

CBC1257700 (Exp: 08/31/2026) 471-817-1259

Sub Contractors

RANDALL SCOTT ROSENFELD
Status Location Address State License Number Phone
ACTIVE

234 N WHITNEY ST

PALM COAST, FL 32084

CAC1816641 (Exp: 08/31/2026) 904-599-0082
DUSTIN L ESTEP
Status Location Address State License Number Phone Fax
ACTIVE

2041 N HIAWASSEE RD

APOPKA, FL 32703

CCC1330971 (Exp: 08/31/2026) 407-702-0206 352-988-6629
JASON PATRICK RIBOCK
Status Location Address State License Number Phone
INACTIVE

620 E PINE ST

, 0

ES12001313 (Exp: 08/31/2026) 407-625-0257
PAUL ERIC FORSTER
Status Location Address State License Number Phone
ACTIVE

6114 GOODMAN RD

JACKSONVILLE, FL 32244

CFC1429261 (Exp: 08/31/2026) 904-647-1820

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 09/12/2023 FINAL APPROVED KSANDOE
Note: 9/8/2023 - PREVIOUS INSPECTION NOTES 9/8/23- Standing water at front doo and in front bedroom please fix. FYI please seal all tubs at floor. 9/1/2023 - PREVIOUS INSPECTION NOTES 8/31/2023 - PREVIOUS INSPECTION NOTES 8/29/2023 - PREVIOUS INSPECTION NOTES Missing gooseneck for dryer vent. Dishwasher drain line needs to route to the top of the cabinet before terminating at sink drain. Energy calcs do not match installed equipent. Breaker for air handler exceeds MOCP
BLD - BUILDING FINAL 09/08/2023 Disapproved - NO FEE JSTEWART
Note: 9/8/23- Standing water at front doo and in front bedroom please fix. FYI please seal all tubs at floor. 9/1/2023 - PREVIOUS INSPECTION NOTES 8/31/2023 - PREVIOUS INSPECTION NOTES 8/29/2023 - PREVIOUS INSPECTION NOTES Missing gooseneck for dryer vent. Dishwasher drain line needs to route to the top of the cabinet before terminating at sink drain. Energy calcs do not match installed equipent. Breaker for air handler exceeds MOCP
BLD - BUILDING FINAL 09/01/2023 CANCELLED BY APPLICANT KSANDOE
Note: 8/31/2023 - PREVIOUS INSPECTION NOTES 8/29/2023 - PREVIOUS INSPECTION NOTES Missing gooseneck for dryer vent. Dishwasher drain line needs to route to the top of the cabinet before terminating at sink drain. Energy calcs do not match installed equipent. Breaker for air handler exceeds MOCP
BLD - BUILDING FINAL 08/31/2023 CANCELLED BY APPLICANT KSANDOE
Note: 8/29/2023 - PREVIOUS INSPECTION NOTES Missing gooseneck for dryer vent. Dishwasher drain line needs to route to the top of the cabinet before terminating at sink drain. Energy calcs do not match installed equipent. Breaker for air handler exceeds MOCP
BLD - BUILDING FINAL 08/29/2023 Disapproved - NO FEE KSANDOE
Note: Missing gooseneck for dryer vent. Dishwasher drain line needs to route to the top of the cabinet before terminating at sink drain. Energy calcs do not match installed equipent. Breaker for air handler exceeds MOCP
ROW - STORMWATER FINAL 08/29/2023 APPROVED GBERTOLA
Note: 8/29/23= At the time of the inspection, all minimum city requirements were met. The builder is responsible for ensuring that nothing changes after this Inspection is approved. ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 8/28/2023 - PREVIOUS INSPECTION NOTES 08/28/23 A LOT DIRT INSIDE THE CULVERT PIPE. NEEDS TO BE CLEANED OUT. NEED TO MATCH GRADE IN THE SWALE AT THE PROPERTY LINES. NEED TO PICK UP ALL TRASH AND DEBRIS ON SITE BEFORE ROW FINAL PASSED.
U -UTILITY RESIDENTIAL FINAL 08/29/2023 APPROVED - AS NOTED LFITZGERALD
Note: work order with city now done as stated by Matt-bldg,super 8/28/2023 - PREVIOUS INSPECTION NOTES replace brokem water meter transmitter wire-contact customer-service@palmcoastgov.com
U -UTILITY RESIDENTIAL FINAL 08/28/2023 Disapproved - NO FEE LFITZGERALD
Note: replace brokem water meter transmitter wire-contact customer-service@palmcoastgov.com
ROW - STORMWATER FINAL 08/28/2023 Disapproved -FEE REQUIRED FSLADISH
Note: 08/28/23 A LOT DIRT INSIDE THE CULVERT PIPE. NEEDS TO BE CLEANED OUT. NEED TO MATCH GRADE IN THE SWALE AT THE PROPERTY LINES. NEED TO PICK UP ALL TRASH AND DEBRIS ON SITE BEFORE ROW FINAL PASSED.
ROW - FINAL APRON (AFTER POUR) 08/28/2023 APPROVED - AS NOTED FSLADISH
Note: 08/28/23 PIPE IS OK. CUTS MADE. HOT PATCH COMPLETED. CULVERT FULL OF DIRT.
ROW- FINAL SURVEY/GRADING CERTIFICATION 08/25/2023 APPROVED - AS NOTED FSLADISH
Note: 08/25/23 CORRECTIONS MADE. 8/24/2023 - PREVIOUS INSPECTION NOTES 08/24/23 NOTHING HAS CHANGED SINCE PREVIOUS INSPECTION, FRONT ROW/PROPERTY LINE IS STILL SHOWING LOWER THAN THE CENTERLINE. Front property line elevations need to be equal or greater than centerline elevation. Property line Section 300, Drawing 300.D, Drawing 300.D,The front property line/right away elevation are to be equal to or greater than the centerline of the road elevation. I WILL NOT FEE YOU FOR THIS INSPECTION. ______________________________________________________________________________________________________________________ 8/22/2023 - PREVIOUS INSPECTION NOTES 08/22/23 Front property line elevationd need to be equal or greater than centerline elevation. Property line Section 300, Drawing 300.D, Drawing 300.D,The front property line/right away elevation are to be equal to or greater than the centerline of the road elevation. Appears rear right property coner will end up negatively inpacting adjacent property owner based on the elevation numbers. Inspector Notes from Inspection 9270 06/27/23 PIPE IS GOOD MAKE SURE TO REMOVE ANY DIRT FROM CULVERT ENDS BEFORE POURING. READY TO POUR. AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS BEFORE POURING. MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL ________________________________________________________________________________________________________________________ 6/23/2023 - PREVIOUS INSPECTION NOTES 06/23/23=ORGANICS NEED TO BE REMOVED FROM THE POUR AREA. * FOOTERS HAVE WASHED IN NEED TO BE DUG OUT NEED 24 INCHES OF #4 REBAR IS PLACED UNDER EACH END OF THE PIPE. PIPE SHOULD BE DUG OUT 6 INCHES DEEP BY 6 INCHES LONG UNDER EACH END OF THE PIPE. culvert pipe elevation is OK
ROW FIELD SURVEY /GRADING CERTIFICATION 08/25/2023 APPROVED FSLADISH
Note: 08/25/23 UPON WALKING PROPERTY APPEARS AS DRAINAGE WILL WORK AS INDICATED. _______________________________________________________________________________________________________________________ 8/24/2023 - PREVIOUS INSPECTION NOTES 08/24/23 PREVIOUS INSPECTION NOTES 08/22/23 YOU MUST FIRST PASS A FINAL SURVEY INSPECTION BEFORE A FIELD SURVEY INSPECTION CAN BE COMPLETED. ________________________________________________________________________________________________________________________ 8/22/2023 - PREVIOUS INSPECTION NOTES 08/22/23 YOU MUST FIRST PASS A FINAL SURVEY INSPECTION BEFORE A FIELD SURVEY INSPECTION CAN BE COMPLETED. _______________________________________________________________________________________________________________________ Inspector Notes from Inspection 9270 06/27/23 PIPE IS GOOD MAKE SURE TO REMOVE ANY DIRT FROM CULVERT ENDS BEFORE POURING. READY TO POUR. AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS BEFORE POURING. MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL ________________________________________________________________________________________________________________________ 6/23/2023 - PREVIOUS INSPECTION NOTES 06/23/23=ORGANICS NEED TO BE REMOVED FROM THE POUR AREA. * FOOTERS HAVE WASHED IN NEED TO BE DUG OUT NEED 24 INCHES OF #4 REBAR IS PLACED UNDER EACH END OF THE PIPE. PIPE SHOULD BE DUG OUT 6 INCHES DEEP BY 6 INCHES LONG UNDER EACH END OF THE PIPE. culvert pipe elevation is OK
ROW- FINAL SURVEY/GRADING CERTIFICATION 08/24/2023 Disapproved - NO FEE FSLADISH
Note: 08/24/23 NOTHING HAS CHANGED SINCE PREVIOUS INSPECTION, FRONT ROW/PROPERTY LINE IS STILL SHOWING LOWER THAN THE CENTERLINE. Front property line elevations need to be equal or greater than centerline elevation. Property line Section 300, Drawing 300.D, Drawing 300.D,The front property line/right away elevation are to be equal to or greater than the centerline of the road elevation. I WILL NOT FEE YOU FOR THIS INSPECTION. ______________________________________________________________________________________________________________________ 8/22/2023 - PREVIOUS INSPECTION NOTES 08/22/23 Front property line elevationd need to be equal or greater than centerline elevation. Property line Section 300, Drawing 300.D, Drawing 300.D,The front property line/right away elevation are to be equal to or greater than the centerline of the road elevation. Appears rear right property coner will end up negatively inpacting adjacent property owner based on the elevation numbers. Inspector Notes from Inspection 9270 06/27/23 PIPE IS GOOD MAKE SURE TO REMOVE ANY DIRT FROM CULVERT ENDS BEFORE POURING. READY TO POUR. AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS BEFORE POURING. MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL ________________________________________________________________________________________________________________________ 6/23/2023 - PREVIOUS INSPECTION NOTES 06/23/23=ORGANICS NEED TO BE REMOVED FROM THE POUR AREA. * FOOTERS HAVE WASHED IN NEED TO BE DUG OUT NEED 24 INCHES OF #4 REBAR IS PLACED UNDER EACH END OF THE PIPE. PIPE SHOULD BE DUG OUT 6 INCHES DEEP BY 6 INCHES LONG UNDER EACH END OF THE PIPE. culvert pipe elevation is OK
ROW FIELD SURVEY /GRADING CERTIFICATION 08/24/2023 Disapproved - NO FEE FSLADISH
Note: 08/24/23 PREVIOUS INSPECTION NOTES 08/22/23 YOU MUST FIRST PASS A FINAL SURVEY INSPECTION BEFORE A FIELD SURVEY INSPECTION CAN BE COMPLETED. ________________________________________________________________________________________________________________________ 8/22/2023 - PREVIOUS INSPECTION NOTES 08/22/23 YOU MUST FIRST PASS A FINAL SURVEY INSPECTION BEFORE A FIELD SURVEY INSPECTION CAN BE COMPLETED. _______________________________________________________________________________________________________________________ Inspector Notes from Inspection 9270 06/27/23 PIPE IS GOOD MAKE SURE TO REMOVE ANY DIRT FROM CULVERT ENDS BEFORE POURING. READY TO POUR. AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS BEFORE POURING. MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL ________________________________________________________________________________________________________________________ 6/23/2023 - PREVIOUS INSPECTION NOTES 06/23/23=ORGANICS NEED TO BE REMOVED FROM THE POUR AREA. * FOOTERS HAVE WASHED IN NEED TO BE DUG OUT NEED 24 INCHES OF #4 REBAR IS PLACED UNDER EACH END OF THE PIPE. PIPE SHOULD BE DUG OUT 6 INCHES DEEP BY 6 INCHES LONG UNDER EACH END OF THE PIPE. culvert pipe elevation is OK
ROW FIELD SURVEY /GRADING CERTIFICATION 08/22/2023 Disapproved - NO FEE FSLADISH
Note: 08/22/23 YOU MUST FIRST PASS A FINAL SURVEY INSPECTION BEFORE A FIELD SURVEY INSPECTION CAN BE COMPLETED. _______________________________________________________________________________________________________________________ Inspector Notes from Inspection 9270 06/27/23 PIPE IS GOOD MAKE SURE TO REMOVE ANY DIRT FROM CULVERT ENDS BEFORE POURING. READY TO POUR. AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS BEFORE POURING. MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL ________________________________________________________________________________________________________________________ 6/23/2023 - PREVIOUS INSPECTION NOTES 06/23/23=ORGANICS NEED TO BE REMOVED FROM THE POUR AREA. * FOOTERS HAVE WASHED IN NEED TO BE DUG OUT NEED 24 INCHES OF #4 REBAR IS PLACED UNDER EACH END OF THE PIPE. PIPE SHOULD BE DUG OUT 6 INCHES DEEP BY 6 INCHES LONG UNDER EACH END OF THE PIPE. culvert pipe elevation is OK
ROW- FINAL SURVEY/GRADING CERTIFICATION 08/22/2023 Disapproved - NO FEE FSLADISH
Note: 08/22/23 front property line elevationd need to be equal or greater than centerline elevation. Property line Section 300, Drawing 300.D, Drawing 300.D,The front property line/right away elevation are to be equal to or greater than the centerline of the road elevation. Appears rear right property coner will end up negatively inpacting adjacent property owner based on the elevation numbers. Inspector Notes from Inspection 9270 06/27/23 PIPE IS GOOD MAKE SURE TO REMOVE ANY DIRT FROM CULVERT ENDS BEFORE POURING. READY TO POUR. AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS BEFORE POURING. MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL ________________________________________________________________________________________________________________________ 6/23/2023 - PREVIOUS INSPECTION NOTES 06/23/23=ORGANICS NEED TO BE REMOVED FROM THE POUR AREA. * FOOTERS HAVE WASHED IN NEED TO BE DUG OUT NEED 24 INCHES OF #4 REBAR IS PLACED UNDER EACH END OF THE PIPE. PIPE SHOULD BE DUG OUT 6 INCHES DEEP BY 6 INCHES LONG UNDER EACH END OF THE PIPE. culvert pipe elevation is OK
U-CROSS CONNECTION 08/22/2023 APPROVED - AS NOTED LFITZGERALD
Note: no irrigation-no cross connection
ELECTRIC - EARLY POWER 07/13/2023 APPROVED - AS NOTED KSANDOE
Note: Emailed FPL @ 1049. Release Power 5/11/2023 - PREVIOUS INSPECTION NOTES Wrong inspection called in. This house is not ready for for early power. Early power is when all drywall is done and all finish electric is safe. This house has an above ground service and does not qualify for TUG ( temporary under ground). In order to get power, you must install a temporary power pole supplied by the electrician.
ROW- PRE-APRON (PRE-POUR) 06/27/2023 APPROVED - AS NOTED FSLADISH
Note: 06/27/23 PIPE IS GOOD MAKE SURE TO REMOVE ANY DIRT FROM CULVERT ENDS BEFORE POURING. READY TO POUR. AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS BEFORE POURING. MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL ________________________________________________________________________________________________________________________ 6/23/2023 - PREVIOUS INSPECTION NOTES 06/23/23=ORGANICS NEED TO BE REMOVED FROM THE POUR AREA. * FOOTERS HAVE WASHED IN NEED TO BE DUG OUT NEED 24 INCHES OF #4 REBAR IS PLACED UNDER EACH END OF THE PIPE. PIPE SHOULD BE DUG OUT 6 INCHES DEEP BY 6 INCHES LONG UNDER EACH END OF THE PIPE. culvert pipe elevation is OK
ROW- PRE-APRON (PRE-POUR) 06/23/2023 Disapproved -FEE REQUIRED GBERTOLA
Note: 06/23/23=ORGANICS NEED TO BE REMOVED FROM THE POUR AREA. * FOOTERS HAVE WASHED IN NEED TO BE DUG OUT NEED 24 INCHES OF #4 REBAR IS PLACED UNDER EACH END OF THE PIPE. PIPE SHOULD BE DUG OUT 6 INCHES DEEP BY 6 INCHES LONG UNDER EACH END OF THE PIPE. culvert pipe elevation is OK
INSULATION 06/01/2023 APPROVED KSANDOE
Note: 5/31/2023 - PREVIOUS INSPECTION NOTES 5/30/2023 - PREVIOUS INSPECTION NOTES Insulation incomplete. Crews still working. Annular holes, plumbing and dryer vent, thermostat wire, empty hole above sink, need to be filled with fire rated foam or caulk Inspector Notes from Inspection 2420 Form boards used as purlins in garage have not been changed out. Bath fan exhaust ducting needs to be supported every 4ft Dryer vent needs nail plates at top plate 5/11/2023 - PREVIOUS INSPECTION NOTES Bath fans not connected to vents Unable to inspect meter can due to stucco crew on site and meter can is taped off
INSULATION 05/31/2023 Disapproved - NO FEE KSANDOE
Note: Annular holes, plumbing and dryer vent, thermostat wire, empty hole above sink, need to be filled with fire rated foam or caulk 5/30/2023 - PREVIOUS INSPECTION NOTES Insulation incomplete. Crews still working. Annular holes, plumbing and dryer vent, thermostat wire, empty hole above sink, need to be filled with fire rated foam or caulk Inspector Notes from Inspection 2420 Form boards used as purlins in garage have not been changed out. Bath fan exhaust ducting needs to be supported every 4ft Dryer vent needs nail plates at top plate 5/11/2023 - PREVIOUS INSPECTION NOTES Bath fans not connected to vents Unable to inspect meter can due to stucco crew on site and meter can is taped off
INSULATION 05/30/2023 Disapproved - NO FEE KSANDOE
Note: Insulation incomplete. Crews still working. Inspector Notes from Inspection 2420 Form boards used as purlins in garage have not been changed out. Bath fan exhaust ducting needs to be supported every 4ft Dryer vent needs nail plates at top plate 5/11/2023 - PREVIOUS INSPECTION NOTES Bath fans not connected to vents Unable to inspect meter can due to stucco crew on site and meter can is taped off
GRAVITY SEWER TEST 05/26/2023 APPROVED - AS NOTED MGIBSON
Note: Inspector Notes from Inspection 2060 REMOVE ANY AND ALL COQUINA ROCK BEFORE BACKFILLING. WILL CHECK AT NEXT INSPECTION THIS WAS A VIRTUAL INSPECTION
U - SEWER TIE IN 05/26/2023 APPROVED - AS NOTED MGIBSON
Note: THIS WAS A VIRTUAL INSPECTION
ALL ROUGH 05/19/2023 APPROVED - AS NOTED KSANDOE
Note: Form boards used as purlins in garage have not been changed out. Bath fan exhaust ducting needs to be supported every 4ft Dryer vent needs nail plates at top plate 5/11/2023 - PREVIOUS INSPECTION NOTES Bath fans not connected to vents Unable to inspect meter can due to stucco crew on site and meter can is taped off
ALL ROUGH 05/11/2023 Disapproved - NO FEE TSTAUFFACHER
Note: Bath fans not connected to vents Unable to inspect meter can due to stucco crew on site and meter can is taped off
ELECTRIC - EARLY POWER 05/11/2023 Disapproved - NO FEE TSTAUFFACHER
Note: Wrong inspection called in. This house is not ready for for early power. Early power is when all drywall is done and all finish electric is safe. This house has an above ground service and does not qualify for TUG ( temporary under ground). In order to get power, you must install a temporary power pole supplied by the electrician.
LATH/BRICK/ WATER BARRIER 05/09/2023 APPROVED MKRASKI
LATH/BRICK/ WATER BARRIER 05/08/2023 CANCELLED BY APPLICANT KSANDOE
ELECTRIC TEMP POLE 04/28/2023 Disapproved -FEE REQUIRED KSANDOE
Note: No temp pole installed. Not ready for inspection
WALL SHEATHING 04/26/2023 APPROVED KSANDOE
ROOF SHEATHING / BRACES/TIES/DOWN CELL 04/26/2023 APPROVED - AS NOTED KSANDOE
Note: Cannot use repurposed materials. 2x10 purlin in garage needs to be replaced.
ROOF SHEATHING 04/26/2023 APPROVED KSANDOE
ROOF VALLEY & METAL 04/26/2023 APPROVED KSANDOE
FOUND SURVEY APPROVED (OFFICE) 04/25/2023 APPROVED TBAKER
TIE BEAM / LINTEL 04/04/2023 APPROVED KSANDOE
MONOLITHIC SLAB 03/21/2023 APPROVED FWILLIS
PLUMBING 1ST ROUGH UNDERGROUND 03/16/2023 APPROVED - AS NOTED MGIBSON
Note: REMOVE ANY AND ALL COQUINA ROCK BEFORE BACKFILLING. WILL CHECK AT NEXT INSPECTION
WATER METER INSTALLATION REQUEST 02/17/2023 APPROVED TSCHWEERS

Review History

Department Status Date In Date Out
MECH COMPLETE 09/06/2023 09/07/2023
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
MECH HOLD 08/31/2023 09/05/2023
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM 1. Energy Calcs need to be signed by the owner/ owner agent below the preparer per R103.1.1.2 FBC Energy Conservation 2020 7Th edition 2. Provide Entire energy calc with heatload and duct layout
ENGIN1 COMPLETE 04/25/2023 04/25/2023
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON COMPLETE 04/25/2023 04/25/2023
Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM no zoning changes
MECH COMPLETE 02/08/2023 02/08/2023
Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM
MECH HOLD 02/02/2023 02/03/2023
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Duct layout needs to be signed by the AC contractor per 107.1 FBC Residential 2020 7th Edition
MECH COMPLETE 01/06/2023 01/06/2023
Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM
ZON COMPLETE 01/06/2023 01/06/2023
Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM
SWALE COMPLETE 12/28/2022 04/11/2023
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
BLD COMPLETE 12/27/2022 12/28/2022
Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM
CUSVC COMPLETE 12/27/2022 12/29/2022
Note: Released By: HALEIGH HAND - -
ELEC COMPLETE 12/27/2022 12/28/2022
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ENGIN1 COMPLETE 12/27/2022 12/28/2022
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
LOCATE COMPLETE 12/27/2022 12/28/2022
Note: Released By: CANDACE STONE - - CSTONE@PALMCOASTGOV.COM
MECH HOLD 12/27/2022 12/28/2022
Note: Held By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM All comments below per the 2020 Florida Building Code – Plumbing REVIEW COMMENTS: 1. Design location on Energy Forms is to be Daytona Beach. 2. Form 405 is to be signed by Owner/Agent
SW1 COMPLETE 12/27/2022 01/05/2023
Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM
ZON HOLD 12/27/2022 12/28/2022
Note: Held By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM Site plan: width of walkway Landscape: Please choose Shrubs for the foundation plantings that will be tolerant in our area this shrub Arboricola is also known as Dwarf Schefflera and is on the non credit planting list. Please look up the commonly used approved shrubs like Holly, vibumum, ligustrum those are tolerant in our area. Please list proposed sod and if it will need irrigation. A/C will need 7 gallon shrubs for screening

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
SW ENG REINSPECTION 20 ¤20.00 09/12/2023
SW ENG REINSPECTION 30 ¤30.00 09/12/2023
PLAN REVIEW - REVISION ¤32.50 09/12/2023
REINSPECTION RESIDENTIAL ¤40.00 09/12/2023
CONTRACTOR CHANGE ¤20.00 04/13/2023
FIRE IMPACT FEE ADMIN ¤12.62 01/23/2023
FIRE IMPACT FEE ADMIN (¤12.62) 01/23/2023
FC IMPACT FEE EMS ¤62.00 01/23/2023
IMPACT FEE FIRE ¤420.52 01/23/2023
FC IMPACT FEE LAW ENFORCEMENT ¤218.00 01/23/2023
FC IMPACT FEE LIBRARY ¤268.00 01/23/2023
IMPACT FEE PARKS ¤1,769.15 01/23/2023
IMPACT FEE SCHOOL ¤5,450.00 01/23/2023
IMPACT FEE TRANSPORTATION ¤1,764.00 01/23/2023
WATER -IRRIGATION INSPECTION ¤25.00 01/23/2023
PARKS IMPACT FEE ADMIN ¤53.07 01/23/2023
PARKS IMPACT FEE ADMIN (¤53.07) 01/23/2023
SURCHARGE FS 533.721 ¤2.47 01/23/2023
SURCHARGE - FS 468.631 ¤3.71 01/23/2023
SW ENG - FOUNDATION SURVEY ¤20.00 01/23/2023
SW ENG INSPECTION 80 ¤80.00 01/23/2023
SW ENG PRE APRON ¤30.00 01/23/2023
CONNECTION FEES ¤1,166.26 01/23/2023
WATER- TURN ON ¤25.00 01/23/2023
ADJUSTMENT 50% (¤366.24) 01/23/2023
ADMINISTRATIVE RESIDENTIAL ¤30.00 01/23/2023
INSPECTION - RESIDENTIAL ¤547.25 01/23/2023
PLAN REVIEW - RESIDENTIAL ¤155.22 01/23/2023
SW ENG - REVIEW 20 ¤20.00 01/23/2023
SW ENG RES REVIEW 200 ¤200.00 01/23/2023
TRANS IMPACT FEE ADMIN ¤52.92 01/23/2023
TRANS IMPACT FEE ADMIN (¤52.92) 01/23/2023
SEWER CREDIT (¤1,147.00) 01/23/2023
SEWER INSPECTION ¤25.00 01/23/2023
SEWER CAPITAL FACILITY ¤5,344.82 01/23/2023
WATER CAPITAL FACILITY FEE ¤3,923.88 01/23/2023
SITE PLAN 30 ¤30.00 01/23/2023
Fees Total Due: ¤0.00 Total Paid: ¤20,209.54