Permit #2022121008

Permit Details

Status: COED

Parcel Id: 07-11-31-7030-00730-0130
CONDITIONED SPACE: 1517 sqft
GARAGE: 394 sqft
Total Square Footage: 1911 sqft
Block: 00730
Subdivision: 2154 - SECTION 30-ROYAL PALMS
Job Phone: 470-817-1259
Location Address: 57 RAMBLEWOOD DR
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 01/23/2023
NOC: RECORDED
Applicant name: WADE GILMER JURNEY JR
Owner: NATIONAL HOEM CORP

Address

1080 HOLCOMB BRIDGE RDO 100-330

ROSWELL, GA 30076

Lot: 0130
Contracted Stated Job Value: ¤209,353.00
Job Description: Single Family Residence
Type: CN

Contractor

NATIONAL HOME CORPORATION
Status Location Address Mailing Address State License Number Phone
INACTIVE

1080 HOLCOMB BRIDGE ROAD

,

BLDG 100 - 330

ROSWELL , GA 30076

CBC1257700 (Exp: 08/31/2026) 471-817-1259

Sub Contractors

RANDALL SCOTT ROSENFELD
Status Location Address State License Number Phone
ACTIVE

234 N WHITNEY ST

PALM COAST, FL 32084

CAC1816641 (Exp: 08/31/2026) 904-599-0082
DUSTIN L ESTEP
Status Location Address State License Number Phone Fax
ACTIVE

2041 N HIAWASSEE RD

APOPKA, FL 32703

CCC1330971 (Exp: 08/31/2026) 407-702-0206 352-988-6629
JASON PATRICK RIBOCK
Status Location Address State License Number Phone
INACTIVE

620 E PINE ST

, 0

ES12001313 (Exp: 08/31/2026) 407-625-0257
PAUL ERIC FORSTER
Status Location Address State License Number Phone
ACTIVE

6114 GOODMAN RD

JACKSONVILLE, FL 32244

CFC1429261 (Exp: 08/31/2026) 904-647-1820

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 12/27/2023 FINAL APPROVED JWALKER
Note: 12/21/2023 - PREVIOUS INSPECTION NOTES 1. The heat accessory label has not been affixed to the AHU. 2. Due to the closet where the AHU is installed being used as the return plenum. The 3 wall penetrations of the pipe off of the water heater will need to be sealed. 3. The Heat pump has been installed in the path of the bedroom emergency window and will need to be relocted to allow for an unobstructed clear pathway. R-310 and 311.
BLD - BUILDING FINAL 12/21/2023 Disapproved - NO FEE JWALKER
Note: 1. The heat accessory label has not been affixed to the AHU. 2. Due to the closet where the AHU is installed being used as the return plenum. The 3 wall penetrations of the pipe off of the water heater will need to be sealed. 3. The Heat pump has been installed in the path of the bedroom emergency window and will need to be relocted to allow for an unobstructed clear pathway. R-310 and 311.
ROW - STORMWATER FINAL 12/21/2023 APPROVED TPOLACEK
Note: 12/21/23 AT THE TIME FROM THE TIME OF THE INSPECTION OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED.
U -UTILITY RESIDENTIAL FINAL 12/21/2023 FINAL APPROVED LFITZGERALD
Note: Inspector Notes from Inspection 9035 no irrigation-no cross connection
ROW FIELD SURVEY /GRADING CERTIFICATION 12/20/2023 APPROVED PFLANAGAN
Note: CORRECTION MADE At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved. ----------------------------------------------------------------------- 12/19/2023 - PREVIOUS INSPECTION NOTES 12/5/2023 - PREVIOUS INSPECTION NOTES STILL NEED TO MAKE THE WATER BE ABLE TO REACH TO THE ROADSIDE SWALE ON THE LEFT SIDE ---------------------------------------------------------------------------- 11/28/2023 - PREVIOUS INSPECTION NOTES THE LEFT SIDE DRAINAGE STILL WILL NOT WORK NEED TO MAKE ALL WATER GO TO ROAD SIDE SWALE ALL WATER IS BEING TRAPED BEHIND THE NEW SOD --------------------------------------------------------------------------- 11/13/2023 - PREVIOUS INSPECTION NOTES 1) THE RIGHT SIDE DRAINAGE PATTERN NEED TO BE FIXED DO TO THE GRADING OF THE ADJACENT LOT THE DRAINAGE IS NOT CONSISTENT FALL FROM BACK TO FRONT 2) THE LEFT SIDE ALL NEW SOD NEED TO MATCH THE EXISTING GRADE SURROUNDING SO WATER DONT GET HELD FROM REACHING ROAD SIDE SWALE
ROW - FINAL APRON (AFTER POUR) 12/20/2023 APPROVED PFLANAGAN
Note: At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved.
ROW FIELD SURVEY /GRADING CERTIFICATION 12/19/2023 CANCELLED BY APPLICANT TPOLACEK
Note: 12/5/2023 - PREVIOUS INSPECTION NOTES STILL NEED TO MAKE THE WATER BE ABLE TO REACH TO THE ROADSIDE SWALE ON THE LEFT SIDE ---------------------------------------------------------------------------- 11/28/2023 - PREVIOUS INSPECTION NOTES THE LEFT SIDE DRAINAGE STILL WILL NOT WORK NEED TO MAKE ALL WATER GO TO ROAD SIDE SWALE ALL WATER IS BEING TRAPED BEHIND THE NEW SOD --------------------------------------------------------------------------- 11/13/2023 - PREVIOUS INSPECTION NOTES 1) THE RIGHT SIDE DRAINAGE PATTERN NEED TO BE FIXED DO TO THE GRADING OF THE ADJACENT LOT THE DRAINAGE IS NOT CONSISTENT FALL FROM BACK TO FRONT 2) THE LEFT SIDE ALL NEW SOD NEED TO MATCH THE EXISTING GRADE SURROUNDING SO WATER DONT GET HELD FROM REACHING ROAD SIDE SWALE
U - SEWER TIE IN 12/07/2023 APPROVED - AS NOTED MGIBSON
Note: THIS WAS A VIRTUAL INSPECTION
GRAVITY SEWER TEST 12/07/2023 APPROVED - AS NOTED MGIBSON
Note: 4/13/2023 - PREVIOUS INSPECTION NOTES Inspector Notes from Inspection 2060 REMOVE ANY AND ALL COQUINA ROCK FROM SLAB BEFORE BACKFILLING SEWERNOT RAN, AT ALL YET. THIS WAS A VIRTUAL INSPECTION
ROW FIELD SURVEY /GRADING CERTIFICATION 12/05/2023 Disapproved -FEE REQUIRED PFLANAGAN
Note: STILL NEED TO MAKE THE WATER BE ABLE TO REACH TO THE ROADSIDE SWALE ON THE LEFT SIDE ---------------------------------------------------------------------------- 11/28/2023 - PREVIOUS INSPECTION NOTES THE LEFT SIDE DRAINAGE STILL WILL NOT WORK NEED TO MAKE ALL WATER GO TO ROAD SIDE SWALE ALL WATER IS BEING TRAPED BEHIND THE NEW SOD --------------------------------------------------------------------------- 11/13/2023 - PREVIOUS INSPECTION NOTES 1) THE RIGHT SIDE DRAINAGE PATTERN NEED TO BE FIXED DO TO THE GRADING OF THE ADJACENT LOT THE DRAINAGE IS NOT CONSISTENT FALL FROM BACK TO FRONT 2) THE LEFT SIDE ALL NEW SOD NEED TO MATCH THE EXISTING GRADE SURROUNDING SO WATER DONT GET HELD FROM REACHING ROAD SIDE SWALE
ROW FIELD SURVEY /GRADING CERTIFICATION 11/28/2023 Disapproved -FEE REQUIRED PFLANAGAN
Note: THE LEFT SIDE DRAINAGE STILL WILL NOT WORK NEED TO MAKE ALL WATER GO TO ROAD SIDE SWALE ALL WATER IS BEING TRAPED BEHIND THE NEW SOD --------------------------------------------------------------------------- 11/13/2023 - PREVIOUS INSPECTION NOTES 1) THE RIGHT SIDE DRAINAGE PATTERN NEED TO BE FIXED DO TO THE GRADING OF THE ADJACENT LOT THE DRAINAGE IS NOT CONSISTENT FALL FROM BACK TO FRONT 2) THE LEFT SIDE ALL NEW SOD NEED TO MATCH THE EXISTING GRADE SURROUNDING SO WATER DONT GET HELD FROM REACHING ROAD SIDE SWALE
ROW- FINAL SURVEY/GRADING CERTIFICATION 11/13/2023 APPROVED PFLANAGAN
Note: At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved. -------------------------------------------------------------------------- 11/1/2023 - PREVIOUS INSPECTION NOTES 11/1/23=NEED TO SUBMIT A NEW FINAL SURVEY. THE LEFT FRONT YARD IS ALL TORE UP . 9/7/2023 - PREVIOUS INSPECTION NOTES 09/07/23 YOUR SITE PLAN SHOWS A COMMON SWALE, YOUR FINAL SURVEY SHOWS A COMMON SWALE. A COMMON SWALE IS REQUIRED. Common Swale required when possible Sec 300.03 C1c Sec 300.03 C1c When grading against a developable vacant lot a 'Common Swale' (meaning the drainage conveyance is on the property line) is required.
ROW FIELD SURVEY /GRADING CERTIFICATION 11/13/2023 Disapproved - NO FEE PFLANAGAN
Note: 1) THE RIGHT SIDE DRAINAGE PATTERN NEED TO BE FIXED DO TO THE GRADING OF THE ADJACENT LOT THE DRAINAGE IS NOT CONSISTENT FALL FROM BACK TO FRONT 2) THE LEFT SIDE ALL NEW SOD NEED TO MATCH THE EXISTING GRADE SURROUNDING SO WATER DONT GET HELD FROM REACHING ROAD SIDE SWALE
ROW- FINAL SURVEY/GRADING CERTIFICATION 11/01/2023 Disapproved - NO FEE GBERTOLA
Note: 11/1/23=NEED TO SUBMIT A NEW FINAL SURVEY. THE LEFT FRONT YARD IS ALL TORE UP . 9/7/2023 - PREVIOUS INSPECTION NOTES 09/07/23 YOUR SITE PLAN SHOWS A COMMON SWALE, YOUR FINAL SURVEY SHOWS A COMMON SWALE. A COMMON SWALE IS REQUIRED. Common Swale required when possible Sec 300.03 C1c Sec 300.03 C1c When grading against a developable vacant lot a 'Common Swale' (meaning the drainage conveyance is on the property line) is required.
U-CROSS CONNECTION 09/20/2023 APPROVED - AS NOTED LFITZGERALD
Note: no irrigation-no cross connection
ELECTRIC - EARLY POWER 09/20/2023 APPROVED JWALKER
Note: 8/11/2023 - PREVIOUS INSPECTION NOTES 1. There is not disconnect installed or wiring for the heat pump. 2. The main electrical panel in the garage is missing the cover.
ROW- FINAL SURVEY/GRADING CERTIFICATION 09/07/2023 Disapproved - NO FEE FSLADISH
Note: 09/07/23 YOUR SITE PLAN SHOWS A COMMON SWALE, YOUR FINAL SURVEY SHOWS A COMMON SWALE. A COMMON SWALE IS REQUIRED. Common Swale required when possible Sec 300.03 C1c Sec 300.03 C1c When grading against a developable vacant lot a 'Common Swale' (meaning the drainage conveyance is on the property line) is required.
PEP TANK INSTALLATION REQUEST 08/31/2023 APPROVED CBOWERMASTER
ELECTRIC - EARLY POWER 08/11/2023 Disapproved -FEE REQUIRED JWALKER
Note: 1. There is not disconnect installed or wiring for the heat pump. 2. The main electrical panel in the garage is missing the cover.
INSULATION 07/06/2023 APPROVED JWALKER
Note: 7/5/2023 - PREVIOUS INSPECTION NOTES 7/5/23: 1). Master Bathroom - pack out wall at bathtub is missing firestop along top plate separation. 2). Laundry room - pack out wall missing firestop along top plate separations. 6/29/2023 - PREVIOUS INSPECTION NOTES 6/29/23 1. Flex has been corrected. 2. Full set of approved energy calculations along with duct layout drawing still not onsite. Inspector Notes from Inspection 2420 6/23/23 Flex duct support listed below has not been corrected CHECK all. Seal the torn flex just above the supply plenum. Energy calculations tacked in the job box are not the complete set and do not contain the approved duct lay out. P Check above listed at INSULATION INSPECTION 5/25/2023 - PREVIOUS INSPECTION NOTES 5/25/23 Below listed correction have not been made. 5/12/2023 - PREVIOUS INSPECTION NOTES 1.The bracing listed from roof brace has not been installed. The X bracing and bottom chord bracing has not been installed. See detail TB05 on page D2. Please have installed before ALL ROUGH inspection. 2. All HVAC flex duct is to be supported minimum of 4' o.c. the flex also needs to be supported where the duct make the bend into the register needs to be supported to prevent kinking of the duct. 3. Bathroom exhaust fan ducts have not been connected and sealed. Duct is 4" and will need a proper transition fitting to attach to the 3" fan outlet. 4. Please have the approved HVAC and product approval sheets onsite for reispection 5. Install a nail plate at the laundry plumbing vent top plate. 6. Spray foam used to seal the annualar spaces is to be of the fire resistant type. Remove the yellow foam or provide the can showing to correct foam type.
INSULATION 07/05/2023 Disapproved - NO FEE RSIMS
Note: 7/5/23: 1). Master Bathroom - pack out wall at bathtub is missing firestop along top plate separation. 2). Laundry room - pack out wall missing firestop along top plate separations. 6/29/2023 - PREVIOUS INSPECTION NOTES 6/29/23 1. Flex has been corrected. 2. Full set of approved energy calculations along with duct layout drawing still not onsite. Inspector Notes from Inspection 2420 6/23/23 Flex duct support listed below has not been corrected CHECK all. Seal the torn flex just above the supply plenum. Energy calculations tacked in the job box are not the complete set and do not contain the approved duct lay out. P Check above listed at INSULATION INSPECTION 5/25/2023 - PREVIOUS INSPECTION NOTES 5/25/23 Below listed correction have not been made. 5/12/2023 - PREVIOUS INSPECTION NOTES 1.The bracing listed from roof brace has not been installed. The X bracing and bottom chord bracing has not been installed. See detail TB05 on page D2. Please have installed before ALL ROUGH inspection. 2. All HVAC flex duct is to be supported minimum of 4' o.c. the flex also needs to be supported where the duct make the bend into the register needs to be supported to prevent kinking of the duct. 3. Bathroom exhaust fan ducts have not been connected and sealed. Duct is 4" and will need a proper transition fitting to attach to the 3" fan outlet. 4. Please have the approved HVAC and product approval sheets onsite for reispection 5. Install a nail plate at the laundry plumbing vent top plate. 6. Spray foam used to seal the annualar spaces is to be of the fire resistant type. Remove the yellow foam or provide the can showing to correct foam type.
INSULATION 06/29/2023 Disapproved -FEE REQUIRED JWALKER
Note: 6/29/23 1. Flex has been corrected. 2. Full set of approved energy calculations along with duct layout drawing still not onsite. Inspector Notes from Inspection 2420 6/23/23 Flex duct support listed below has not been corrected CHECK all. Seal the torn flex just above the supply plenum. Energy calculations tacked in the job box are not the complete set and do not contain the approved duct lay out. P Check above listed at INSULATION INSPECTION 5/25/2023 - PREVIOUS INSPECTION NOTES 5/25/23 Below listed correction have not been made. 5/12/2023 - PREVIOUS INSPECTION NOTES 1.The bracing listed from roof brace has not been installed. The X bracing and bottom chord bracing has not been installed. See detail TB05 on page D2. Please have installed before ALL ROUGH inspection. 2. All HVAC flex duct is to be supported minimum of 4' o.c. the flex also needs to be supported where the duct make the bend into the register needs to be supported to prevent kinking of the duct. 3. Bathroom exhaust fan ducts have not been connected and sealed. Duct is 4" and will need a proper transition fitting to attach to the 3" fan outlet. 4. Please have the approved HVAC and product approval sheets onsite for reispection 5. Install a nail plate at the laundry plumbing vent top plate. 6. Spray foam used to seal the annualar spaces is to be of the fire resistant type. Remove the yellow foam or provide the can showing to correct foam type.
ROW- PRE-APRON (PRE-POUR) 06/27/2023 APPROVED FSLADISH
Note: 06/27/23 PIPE IS GOOD READY TO POUR. LOOKED GOOD AT TIME OF INSPECTION. AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS BEFORE POURING. MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL
ALL ROUGH 06/23/2023 APPROVED - AS NOTED JWALKER
Note: 6/23/23 Flex duct support listed below has not been corrected CHECK all. Seal the torn flex just above the supply plenum. Energy calculations tacked in the job box are not the complete set and do not contain the approved duct lay out. P Check above listed at INSULATION INSPECTION 5/25/2023 - PREVIOUS INSPECTION NOTES 5/25/23 Below listed correction have not been made. 5/12/2023 - PREVIOUS INSPECTION NOTES 1.The bracing listed from roof brace has not been installed. The X bracing and bottom chord bracing has not been installed. See detail TB05 on page D2. Please have installed before ALL ROUGH inspection. 2. All HVAC flex duct is to be supported minimum of 4' o.c. the flex also needs to be supported where the duct make the bend into the register needs to be supported to prevent kinking of the duct. 3. Bathroom exhaust fan ducts have not been connected and sealed. Duct is 4" and will need a proper transition fitting to attach to the 3" fan outlet. 4. Please have the approved HVAC and product approval sheets onsite for reispection 5. Install a nail plate at the laundry plumbing vent top plate. 6. Spray foam used to seal the annualar spaces is to be of the fire resistant type. Remove the yellow foam or provide the can showing to correct foam type.
ALL ROUGH 05/25/2023 Disapproved -FEE REQUIRED JWALKER
Note: 5/25/23 Below listed correction have not been made. 5/12/2023 - PREVIOUS INSPECTION NOTES 1.The bracing listed from roof brace has not been installed. The X bracing and bottom chord bracing has not been installed. See detail TB05 on page D2. Please have installed before ALL ROUGH inspection. 2. All HVAC flex duct is to be supported minimum of 4' o.c. the flex also needs to be supported where the duct make the bend into the register needs to be supported to prevent kinking of the duct. 3. Bathroom exhaust fan ducts have not been connected and sealed. Duct is 4" and will need a proper transition fitting to attach to the 3" fan outlet. 4. Please have the approved HVAC and product approval sheets onsite for reispection 5. Install a nail plate at the laundry plumbing vent top plate. 6. Spray foam used to seal the annualar spaces is to be of the fire resistant type. Remove the yellow foam or provide the can showing to correct foam type. 5/25/23 Please disregaurd items numbered 3,5 and 6.
ALL ROUGH 05/12/2023 Disapproved - NO FEE JWALKER
Note: 1.The bracing listed from roof brace has not been installed. The X bracing and bottom chord bracing has not been installed. See detail TB05 on page D2. Please have installed before ALL ROUGH inspection. 2. All HVAC flex duct is to be supported minimum of 4' o.c. the flex also needs to be supported where the duct make the bend into the register needs to be supported to prevent kinking of the duct. 3. Bathroom exhaust fan ducts have not been connected and sealed. Duct is 4" and will need a proper transition fitting to attach to the 3" fan outlet. 4. Please have the approved HVAC and product approval sheets onsite for reispection
LATH/BRICK/ WATER BARRIER 05/09/2023 APPROVED JWALKER
LATH/BRICK/ WATER BARRIER 05/08/2023 CANCELLED BY APPLICANT JWALKER
WALL SHEATHING 05/05/2023 APPROVED JWALKER
ROOF SHEATHING / BRACES/TIES/DOWN CELL 05/05/2023 APPROVED - AS NOTED JWALKER
Note: The X bracing and bottom chord bracing has not been installed. See detail TB05 on page D2. Please have installed before ALL ROUGH inspection.
ROOF SHEATHING 05/05/2023 APPROVED JWALKER
ROOF VALLEY & METAL 05/05/2023 APPROVED JWALKER
FOUND SURVEY APPROVED (OFFICE) 05/04/2023 APPROVED TBAKER
GRAVITY SEWER TEST 04/13/2023 Disapproved -FEE REQUIRED MGIBSON
Note: Inspector Notes from Inspection 2060 REMOVE ANY AND ALL COQUINA ROCK FROM SLAB BEFORE BACKFILLING SEWERNOT RAN, AT ALL YET
TIE BEAM / LINTEL 04/04/2023 APPROVED JWALKER
MONOLITHIC SLAB 03/23/2023 APPROVED JWALKER
Note: 3/21/2023 - PREVIOUS INSPECTION NOTES Slab depth is to be a minimum of 4". Note 2 on page S-1. Test lines have been left in place. Please remove excess soil and reinstall string lines for depth check
MONOLITHIC SLAB 03/21/2023 Disapproved - NO FEE JWALKER
Note: Slab depth is to be a minimum of 4". Note 2 on page S-1. Test lines have been left in place. Please remove excess soil and reinstall string lines for depth check
PLUMBING 1ST ROUGH UNDERGROUND 03/16/2023 APPROVED - AS NOTED MGIBSON
Note: REMOVE ANY AND ALL COQUINA ROCK FROM SLAB BEFORE BACKFILLING
WATER METER INSTALLATION REQUEST 03/16/2023 APPROVED CSTONE

Review History

Department Status Date In Date Out
BADMIN INFORMATION 10/31/2023 10/31/2023
Note: Marked INFORMATION By: BARBIE BEMBRY - (386)986-3780 - BUILDINGDIVISION@PALMCOASTGOV.COM A final survey was not uploaded
BLD COMPLETE 06/20/2023 06/23/2023
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
ENGIN1 COMPLETE 05/03/2023 05/04/2023
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON COMPLETE 05/03/2023 05/03/2023
Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM
MECH COMPLETE 02/08/2023 02/09/2023
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
MECH HOLD 02/02/2023 02/03/2023
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Duct layout needs to be signed by the AC contractor per 107.1 FBC Residential 2020 7th Edition
ZON COMPLETE 01/11/2023 01/12/2023
Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM
ENGIN1 COMPLETE 01/11/2023 01/12/2023
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
SW1 COMPLETE 01/11/2023 01/19/2023
Note: Released By: EDWARD MADISON - - EMADISON@PALMCOASTGOV.COM
MECH COMPLETE 01/06/2023 01/06/2023
Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM
ZON HOLD 01/06/2023 01/06/2023
Note: Held By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM Site Plan is missing a rear setback
SWALE COMPLETE 12/28/2022 04/13/2023
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
BLD COMPLETE 12/27/2022 12/28/2022
Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM
CUSVC COMPLETE 12/27/2022 12/29/2022
Note: Released By: HALEIGH HAND - -
ELEC COMPLETE 12/27/2022 12/28/2022
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ENGIN1 COMPLETE 12/27/2022 12/28/2022
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
LOCATE COMPLETE 12/27/2022 12/29/2022
Note: Released By: CANDACE STONE - - CSTONE@PALMCOASTGOV.COM
MECH HOLD 12/27/2022 12/28/2022
Note: Held By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM All comments below per the 2020 Florida Building Code – Plumbing REVIEW COMMENTS: 1. Design location on Energy Forms is to be Daytona Beach. 2. Form 405 is to be signed by Owner/Agent
SW1 COMPLETE 12/27/2022 01/05/2023
Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM
ZON HOLD 12/27/2022 12/28/2022
Note: Held By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM Site plan: width of walkway Landscape: Please choose Shrubs for the foundation plantings that will be tolerant in our area this shrub Arboricola is also known as Dwarf Schefflera and is on the non credit planting list. Please look up the commonly used approved shrubs like Holly, vibumum, ligustrum those are tolerant in our area. Please list proposed sod and if it will need irrigation. A/C will need 7 gallon shrubs for screening

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION RESIDENTIAL ¤40.00 12/22/2023
SW ENG REINSPECTION 20 ¤20.00 12/22/2023
SW ENG REINSPECTION 20 ¤20.00 12/22/2023
PLAN REVIEW - REVISION ¤32.50 07/07/2023
REINSPECTION RESIDENTIAL ¤40.00 07/07/2023
REINSPECTION RESIDENTIAL ¤40.00 07/07/2023
PLAN REVIEW - REVISION ¤32.50 04/13/2023
REINSPECTION RESIDENTIAL ¤40.00 04/13/2023
CONTRACTOR CHANGE ¤20.00 04/13/2023
FIRE IMPACT FEE ADMIN ¤12.62 01/23/2023
FIRE IMPACT FEE ADMIN (¤12.62) 01/23/2023
FC IMPACT FEE EMS ¤62.00 01/23/2023
IMPACT FEE FIRE ¤420.52 01/23/2023
FC IMPACT FEE LAW ENFORCEMENT ¤218.00 01/23/2023
FC IMPACT FEE LIBRARY ¤268.00 01/23/2023
IMPACT FEE PARKS ¤1,769.15 01/23/2023
IMPACT FEE SCHOOL ¤5,450.00 01/23/2023
IMPACT FEE TRANSPORTATION ¤1,764.00 01/23/2023
WATER -IRRIGATION INSPECTION ¤25.00 01/23/2023
PARKS IMPACT FEE ADMIN ¤53.07 01/23/2023
PARKS IMPACT FEE ADMIN (¤53.07) 01/23/2023
SURCHARGE FS 533.721 ¤2.58 01/23/2023
SURCHARGE - FS 468.631 ¤3.88 01/23/2023
SW ENG - FOUNDATION SURVEY ¤20.00 01/23/2023
SW ENG INSPECTION 80 ¤80.00 01/23/2023
SW ENG PRE APRON ¤30.00 01/23/2023
WATER- TURN ON ¤25.00 01/23/2023
ADJUSTMENT 50% (¤385.65) 01/23/2023
ADMINISTRATIVE RESIDENTIAL ¤30.00 01/23/2023
INSPECTION - RESIDENTIAL ¤577.50 01/23/2023
PLAN REVIEW - RESIDENTIAL ¤163.80 01/23/2023
SW ENG - REVIEW 20 ¤20.00 01/23/2023
SW ENG RES REVIEW 200 ¤200.00 01/23/2023
TRANS IMPACT FEE ADMIN ¤52.92 01/23/2023
TRANS IMPACT FEE ADMIN (¤52.92) 01/23/2023
SEWER CREDIT (¤1,147.00) 01/23/2023
SEWER INSPECTION ¤25.00 01/23/2023
SEWER CAPITAL FACILITY ¤5,344.82 01/23/2023
WATER CAPITAL FACILITY FEE ¤3,923.88 01/23/2023
SITE PLAN 30 ¤30.00 01/23/2023
CONNECTION FEES ¤1,166.26 01/23/2023
Fees Total Due: ¤0.00 Total Paid: ¤20,371.74