I want to search for...

Permit #2022121011

Permit Details

Status: COED

Parcel Id: 07-11-31-7032-00370-0260
GARAGE: 394 sqft
CONDITIONED SPACE: 1517 sqft
Total Square Footage: 1911 sqft
Block: 00370
Subdivision: 2155 - SECTION 32-ROYAL PALMS
Job Phone: 470-817-1259
Location Address: 51 RUSSO DR
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 01/23/2023
NOC: RECORDED
Applicant name: WADE GILMER JURNEY JR
Owner: NATIONAL HOME CORP

Address

1080 HOLCOMB BRIDGE RD 100-330

ROSWELL, GA 30076

Lot: 0260
Contracted Stated Job Value: ¤209,353.00
Job Description: Single Family Residence
Type: CN

Contractor

NATIONAL HOME CORPORATION
Status Location Address Mailing Address State License Number Phone
INACTIVE

1080 HOLCOMB BRIDGE ROAD

,

BLDG 100 - 330

ROSWELL , GA 30076

CBC1257700 (Exp: 08/31/2026) 471-817-1259

Sub Contractors

RANDALL SCOTT ROSENFELD
Status Location Address State License Number Phone
ACTIVE

234 N WHITNEY ST

PALM COAST, FL 32084

CAC1816641 (Exp: 08/31/2026) 904-599-0082
DUSTIN L ESTEP
Status Location Address State License Number Phone Fax
ACTIVE

2041 N HIAWASSEE RD

APOPKA, FL 32703

CCC1330971 (Exp: 08/31/2026) 407-702-0206 352-988-6629
JASON PATRICK RIBOCK
Status Location Address State License Number Phone
INACTIVE

620 E PINE ST

, 0

ES12001313 (Exp: 08/31/2026) 407-625-0257
PAUL ERIC FORSTER
Status Location Address State License Number Phone
ACTIVE

6114 GOODMAN RD

JACKSONVILLE, FL 32244

CFC1429261 (Exp: 08/31/2026) 904-647-1820

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 12/14/2023 FINAL APPROVED JWALKER
Note: 12/12/2023 - PREVIOUS INSPECTION NOTES `1. AHU calls for a max 30 amp circuit breaker. A 35 amp is installed at the panel. 2. Missing locking cap at the Heat pump. The center port. 3. Kitchen outlet on the penisula and letf side of the sink are not GFI protected. 4. Interior garage door is missing the bottom threshold seal.
U -UTILITY RESIDENTIAL FINAL 12/13/2023 FINAL APPROVED LFITZGERALD
Note: 12/7/2023 - PREVIOUS INSPECTION NOTES lower sewer C/O
BLD - BUILDING FINAL 12/12/2023 Disapproved - NO FEE JWALKER
Note: `1. AHU calls for a max 30 amp circuit breaker. A 35 amp is installed at the panel. 2. Missing locking cap at the Heat pump. The center port. 3. Kitchen outlet on the penisula and letf side of the sink are not GFI protected. 4. Interior garage door is missing the bottom threshold seal.
ROW - STORMWATER FINAL 12/07/2023 APPROVED PFLANAGAN
Note: IT IS NECESSARY TO REMOVE ALL THE BURIED TREES FROM THE BACKYARD. THEY SHOULD NOT BE BURIED AND INSTEAD, HAULED OUT OF THE PROPERTY. check picture.
U -UTILITY RESIDENTIAL FINAL 12/07/2023 Disapproved -FEE REQUIRED LFITZGERALD
Note: lower sewer C/O
ROW - FINAL APRON (AFTER POUR) 12/06/2023 APPROVED PFLANAGAN
Note: At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved.
ROW- FINAL SURVEY/GRADING CERTIFICATION 12/06/2023 APPROVED PFLANAGAN
Note: At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved. ----------------------------------------------------------------- 11/21/2023 - PREVIOUS INSPECTION NOTES THIS IS THE SAME FINAL SURVEY NEED TO SUBMIT A NEW FINAL SURVEY ------------------------------------------------------------------- 11/13/2023 - PREVIOUS INSPECTION NOTES 1) NEED TO HAVE THE FFE ON ALL IMPROVED LOT IN THE FIELD THERE ARE A FEW HOMES THAT NEED FFE 2) NEED TO HAVE A SWALE ALONG RIGHT SIDE OF LOT SO WATER WILL NOT IMPACT THE LOT TO THE RIGHT OF YOURS 3) NEED TO BUILD THE BACK PROPERTY LINE UP MORE THERE IS NOT HIGH ENOUGH TO STOP THE WATER FROM IMPACTING THE LOT BEHIND YOURS ------------------------------------------------------------------------------------- 11/1/2023 - PREVIOUS INSPECTION NOTES 11/1/23= NEED TO ADD FFE, THERE IS A HOUSE IN THE BACK INSTEAD OF AN EMPTY LOT. NEED TO REGRADE THE BACKYARD BECAUSE IT IS AFFECTING THE HOUSE LOCATED AT THE BACK. IT IS NECESSARY TO REMOVE ALL THE BURIED TREES FROM THE BACKYARD. THEY SHOULD NOT BE BURIED AND INSTEAD, HAULED OUT OF THE PROPERTY. Unless specifically stated the subject lot must drain from back to front or a portion may be drained to an adjacent City drainage feature. (B)?The subject lots drainage must not negatively impact any adjacent property. (B)B.Land Development Code Technical Manual, Section 300.01 (A)(1)(C)(6)
ROW FIELD SURVEY /GRADING CERTIFICATION 12/06/2023 APPROVED PFLANAGAN
Note: At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved. ------------------------------------------------------------------------------- 11/13/2023 - PREVIOUS INSPECTION NOTES THIS INSPECTION IS DONE AFTER THE FINAL SURVEY PASSES ------------------------------------------------------------------------------------------ 11/1/2023 - PREVIOUS INSPECTION NOTES 11/1/23= NEED TO ADD FFE, THERE IS A HOUSE IN THE BACK INSTEAD OF AN EMPTY LOT. NEED TO REGRADE THE BACKYARD BECAUSE IT IS AFFECTING THE HOUSE LOCATED AT THE BACK. Unless specifically stated the subject lot must drain from back to front or a portion may be drained to an adjacent City drainage feature. (B)?The subject lots drainage must not negatively impact any adjacent property. (B)B.Land Development Code Technical Manual, Section 300.01 (A)(1)(C)(6)
ROW- FINAL SURVEY/GRADING CERTIFICATION 11/21/2023 Disapproved -FEE REQUIRED PFLANAGAN
Note: THIS IS THE SAME FINAL SURVEY NEED TO SUBMIT A NEW FINAL SURVEY ------------------------------------------------------------------- 11/13/2023 - PREVIOUS INSPECTION NOTES 1) NEED TO HAVE THE FFE ON ALL IMPROVED LOT IN THE FIELD THERE ARE A FEW HOMES THAT NEED FFE 2) NEED TO HAVE A SWALE ALONG RIGHT SIDE OF LOT SO WATER WILL NOT IMPACT THE LOT TO THE RIGHT OF YOURS 3) NEED TO BUILD THE BACK PROPERTY LINE UP MORE THERE IS NOT HIGH ENOUGH TO STOP THE WATER FROM IMPACTING THE LOT BEHIND YOURS ------------------------------------------------------------------------------------- 11/1/2023 - PREVIOUS INSPECTION NOTES 11/1/23= NEED TO ADD FFE, THERE IS A HOUSE IN THE BACK INSTEAD OF AN EMPTY LOT. NEED TO REGRADE THE BACKYARD BECAUSE IT IS AFFECTING THE HOUSE LOCATED AT THE BACK. IT IS NECESSARY TO REMOVE ALL THE BURIED TREES FROM THE BACKYARD. THEY SHOULD NOT BE BURIED AND INSTEAD, HAULED OUT OF THE PROPERTY. Unless specifically stated the subject lot must drain from back to front or a portion may be drained to an adjacent City drainage feature. (B)?The subject lots drainage must not negatively impact any adjacent property. (B)B.Land Development Code Technical Manual, Section 300.01 (A)(1)(C)(6)
ROW- FINAL SURVEY/GRADING CERTIFICATION 11/13/2023 Disapproved -FEE REQUIRED PFLANAGAN
Note: 1) NEED TO HAVE THE FFE ON ALL IMPROVED LOT IN THE FIELD THERE ARE A FEW HOMES THAT NEED FFE 2) NEED TO HAVE A SWALE ALONG RIGHT SIDE OF LOT SO WATER WILL NOT IMPACT THE LOT TO THE RIGHT OF YOURS 3) NEED TO BUILD THE BACK PROPERTY LINE UP MORE THERE IS NOT HIGH ENOUGH TO STOP THE WATER FROM IMPACTING THE LOT BEHIND YOURS ------------------------------------------------------------------------------------- 11/1/2023 - PREVIOUS INSPECTION NOTES 11/1/23= NEED TO ADD FFE, THERE IS A HOUSE IN THE BACK INSTEAD OF AN EMPTY LOT. NEED TO REGRADE THE BACKYARD BECAUSE IT IS AFFECTING THE HOUSE LOCATED AT THE BACK. IT IS NECESSARY TO REMOVE ALL THE BURIED TREES FROM THE BACKYARD. THEY SHOULD NOT BE BURIED AND INSTEAD, HAULED OUT OF THE PROPERTY. Unless specifically stated the subject lot must drain from back to front or a portion may be drained to an adjacent City drainage feature. (B)?The subject lots drainage must not negatively impact any adjacent property. (B)B.Land Development Code Technical Manual, Section 300.01 (A)(1)(C)(6)
ROW FIELD SURVEY /GRADING CERTIFICATION 11/13/2023 Disapproved - NO FEE PFLANAGAN
Note: THIS INSPECTION IS DONE AFTER THE FINAL SURVEY PASSES ------------------------------------------------------------------------------------------ 11/1/2023 - PREVIOUS INSPECTION NOTES 11/1/23= NEED TO ADD FFE, THERE IS A HOUSE IN THE BACK INSTEAD OF AN EMPTY LOT. NEED TO REGRADE THE BACKYARD BECAUSE IT IS AFFECTING THE HOUSE LOCATED AT THE BACK. Unless specifically stated the subject lot must drain from back to front or a portion may be drained to an adjacent City drainage feature. (B)?The subject lots drainage must not negatively impact any adjacent property. (B)B.Land Development Code Technical Manual, Section 300.01 (A)(1)(C)(6)
ROW FIELD SURVEY /GRADING CERTIFICATION 11/01/2023 Disapproved - NO FEE GBERTOLA
Note: 11/1/23= NEED TO ADD FFE, THERE IS A HOUSE IN THE BACK INSTEAD OF AN EMPTY LOT. NEED TO REGRADE THE BACKYARD BECAUSE IT IS AFFECTING THE HOUSE LOCATED AT THE BACK. Unless specifically stated the subject lot must drain from back to front or a portion may be drained to an adjacent City drainage feature. (B)?The subject lots drainage must not negatively impact any adjacent property. (B)B.Land Development Code Technical Manual, Section 300.01 (A)(1)(C)(6) IT IS NECESSARY TO REMOVE ALL THE BURIED TREES FROM THE BACKYARD. THEY SHOULD NOT BE BURIED AND INSTEAD, HAULED OUT OF THE PROPERTY.
ROW- FINAL SURVEY/GRADING CERTIFICATION 11/01/2023 Disapproved - NO FEE GBERTOLA
Note: 11/1/23= NEED TO ADD FFE, THERE IS A HOUSE IN THE BACK INSTEAD OF AN EMPTY LOT. NEED TO REGRADE THE BACKYARD BECAUSE IT IS AFFECTING THE HOUSE LOCATED AT THE BACK. Unless specifically stated the subject lot must drain from back to front or a portion may be drained to an adjacent City drainage feature. (B)?The subject lots drainage must not negatively impact any adjacent property. (B)B.Land Development Code Technical Manual, Section 300.01 (A)(1)(C)(6) IT IS NECESSARY TO REMOVE ALL THE BURIED TREES FROM THE BACKYARD. THEY SHOULD NOT BE BURIED AND INSTEAD, HAULED OUT OF THE PROPERTY.
GRAVITY SEWER TEST 09/08/2023 APPROVED - AS NOTED MGIBSON
Note: THIS WAS A VIRTUAL INSPECTION
ELECTRIC - EARLY POWER 08/21/2023 APPROVED JWALKER
ROW- PRE-APRON (PRE-POUR) 08/17/2023 APPROVED FSLADISH
Note: 08/17/23 PIPE IS NOW WITHIN TOLERANCE. LOOKED GOOD AT THE TIME OF THIS INSPECTION. READY TO POUR. At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved. This includes but is not limited to, the Culvert Pipe Elevation from the time of the inspection approval to the concrete pour. AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS BEFORE POURING. MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL 8/15/2023 - PREVIOUS INSPECTION NOTES 8/4/2023 - PREVIOUS INSPECTION NOTES *Culvert out of Tolerence. Three tenths too high. See Swale plan. Sub may have set it to the Sod elevation numbers at each end of the pipe on the swale plan. *Too many Organics in the pour area. Remove the many large roots sticking up above the pour depth.
U - SEWER TIE IN 08/15/2023 APPROVED - AS NOTED MGIBSON
Note: THIS WAS A VIRTUAL INSPECTION
ROW- PRE-APRON (PRE-POUR) 08/15/2023 CANCELLED BY APPLICANT FSLADISH
Note: 8/4/2023 - PREVIOUS INSPECTION NOTES *Culvert out of Tolerence. Three tenths too high. See Swale plan. Sub may have set it to the Sod elevation numbers at each end of the pipe on the swale plan. *Too many Organics in the pour area. Remove the many large roots sticking up above the pour depth.
U-CROSS CONNECTION 08/15/2023 APPROVED - AS NOTED LFITZGERALD
Note: no irrigation -no cross connection
ROW- PRE-APRON (PRE-POUR) 08/04/2023 Disapproved -FEE REQUIRED RGROSS
Note: *Culvert out of Tolerence. Three tenths too high. See Swale plan. Sub may have set it to the Sod elevation numbers at each end of the pipe on the swale plan. *Too many Organics in the pour area. Remove the many large roots sticking up above the pour depth.
INSULATION 06/29/2023 APPROVED JWALKER
Note: Inspector Notes from Inspection 2420 5/25/2023 - PREVIOUS INSPECTION NOTES 1. Flex duct is to be supported minimum of 4' o.c. Where the flex turns into the register needs to be supported also to prevent kinking. 2. Install a nail plate at the top plate of the laundry plumbing vent. 3. Bathroom fan exhaust ducts have not been connected and sealed to the fans. 4. The spray foam used to seal the annualar spaces is to be of the fire resistant type. Remove yellow foam or provide the can used showing the UL listing. 6-23-23 1. Install a nail plate at the top plate of the laundry plumbing vent.
ALL ROUGH 06/23/2023 APPROVED - AS NOTED BTAYLOR
Note: 5/25/2023 - PREVIOUS INSPECTION NOTES 1. Flex duct is to be supported minimum of 4' o.c. Where the flex turns into the register needs to be supported also to prevent kinking. 2. Install a nail plate at the top plate of the laundry plumbing vent. 3. Bathroom fan exhaust ducts have not been connected and sealed to the fans. 4. The spray foam used to seal the annualar spaces is to be of the fire resistant type. Remove yellow foam or provide the can used showing the UL listing. 6-23-23 1. Install a nail plate at the top plate of the laundry plumbing vent.
LATH/BRICK/ WATER BARRIER 06/05/2023 APPROVED JWALKER
ALL ROUGH 05/25/2023 Disapproved - NO FEE JWALKER
Note: 1. Flex duct is to be supported minimum of 4' o.c. Where the flex turns into the register needs to be supported also to prevent kinking. 2. Install a nail plate at the top plate of the laundry plumbing vent. 3. Bathroom fan exhaust ducts have not been connected and sealed to the fans. 4. The spray foam used to seal the annualar spaces is to be of the fire resistant type. Remove yellow foam or provide the can used showing the UL listing.
ROOF VALLEY & METAL 05/18/2023 APPROVED JWALKER
Note: 5/16/2023 - PREVIOUS INSPECTION NOTES Under layment not covering decking 100% front garage corner
ROOF VALLEY & METAL 05/16/2023 Disapproved - NO FEE MKRASKI
Note: Under layment not covering decking 100% front garage corner
WALL SHEATHING 05/05/2023 APPROVED KSANDOE
ROOF SHEATHING / BRACES/TIES/DOWN CELL 05/05/2023 APPROVED - AS NOTED KSANDOE
Note: Cannot repurpose wood. Purlin in garage needs to be replaced. 104.9.1 Used materials and equipment. The use of used materials that meet the requirements of this code for new materials is permitted. Used equipment and devices shall not be reused unless approved by the building official
ROOF SHEATHING 05/05/2023 APPROVED - AS NOTED KSANDOE
Note: Knock back shiners and nail off roof sheathing per code
FOUND SURVEY APPROVED (OFFICE) 04/25/2023 APPROVED TBAKER
TIE BEAM / LINTEL 04/20/2023 APPROVED JWALKER
Note: 4/19/2023 - PREVIOUS INSPECTION NOTES 4/18/2023 - PREVIOUS INSPECTION NOTES The prints in the job box are from 19 birchview pl. Please have a full set of approved prints onsite that are site specific for inspections.
TIE BEAM / LINTEL 04/19/2023 CANCELLED BY APPLICANT MKRASKI
Note: 4/18/2023 - PREVIOUS INSPECTION NOTES The prints in the job box are from 19 birchview pl. Please have a full set of approved prints onsite that are site specific for inspections.
TIE BEAM / LINTEL 04/18/2023 Disapproved - NO FEE JWALKER
Note: The prints in the job box are from 19 birchview pl. Please have a full set of approved prints onsite that are site specific for inspections.
MONOLITHIC SLAB 03/30/2023 APPROVED RSIMS
PLUMBING 1ST ROUGH UNDERGROUND 03/17/2023 APPROVED JWALKER
WATER METER INSTALLATION REQUEST 03/17/2023 APPROVED CSTONE

Review History

Department Status Date In Date Out
BADMIN INFORMATION 11/06/2023 11/06/2023
Note: Marked INFORMATION By: BARBIE BEMBRY - (386)986-3780 - BUILDINGDIVISION@PALMCOASTGOV.COM Nothing was uploaded.
BADMIN INFORMATION 10/31/2023 10/31/2023
Note: Marked INFORMATION By: BARBIE BEMBRY - (386)986-3780 - BUILDINGDIVISION@PALMCOASTGOV.COM Please rename your file (remove anything from in front of 'final survey' )
ENGIN1 COMPLETE 04/25/2023 04/25/2023
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON COMPLETE 04/25/2023 04/25/2023
Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM
MECH COMPLETE 02/08/2023 02/09/2023
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
MECH HOLD 02/02/2023 02/03/2023
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Duct layout needs to be signed by the AC contractor per 107.1 FBC Residential 2020 7th Edition
MECH COMPLETE 01/06/2023 01/06/2023
Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM
ZON COMPLETE 01/06/2023 01/06/2023
Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM
SWALE COMPLETE 12/28/2022 04/11/2023
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
BLD COMPLETE 12/27/2022 12/28/2022
Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM
CUSVC COMPLETE 12/27/2022 12/29/2022
Note: Released By: HALEIGH HAND - -
ELEC COMPLETE 12/27/2022 12/28/2022
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ENGIN1 COMPLETE 12/27/2022 12/28/2022
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
LOCATE COMPLETE 12/27/2022 12/29/2022
Note: Released By: CANDACE STONE - - CSTONE@PALMCOASTGOV.COM
MECH HOLD 12/27/2022 12/28/2022
Note: Held By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM All comments below per the 2020 Florida Building Code – Plumbing REVIEW COMMENTS: 1. Design location on Energy Forms is to be Daytona Beach. 2. Form 405 is to be signed by Owner/Agent
SW1 COMPLETE 12/27/2022 01/05/2023
Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM
ZON HOLD 12/27/2022 12/28/2022
Note: Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM Please provide width of front entry walkway on site plan/survey AC screening should be 7 gallon Please provide sod type and if irrigation will be installed Please choose Shrubs for the foundation plantings that will be tolerant in our area this shrub Arboricola is also known as Dwarf Schefflera and is on the non credit planting list.

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION FEE ¤40.00 12/13/2023
SW ENG REINSPECTION 30 ¤30.00 12/13/2023
PLAN REVIEW - REVISION ¤32.50 04/13/2023
CONTRACTOR CHANGE ¤20.00 04/13/2023
FIRE IMPACT FEE ADMIN ¤12.62 01/23/2023
FIRE IMPACT FEE ADMIN (¤12.62) 01/23/2023
FC IMPACT FEE EMS ¤62.00 01/23/2023
IMPACT FEE FIRE ¤420.52 01/23/2023
FC IMPACT FEE LAW ENFORCEMENT ¤218.00 01/23/2023
FC IMPACT FEE LIBRARY ¤268.00 01/23/2023
IMPACT FEE PARKS ¤1,769.15 01/23/2023
IMPACT FEE SCHOOL ¤5,450.00 01/23/2023
IMPACT FEE TRANSPORTATION ¤1,764.00 01/23/2023
WATER -IRRIGATION INSPECTION ¤25.00 01/23/2023
PARKS IMPACT FEE ADMIN ¤53.07 01/23/2023
PARKS IMPACT FEE ADMIN (¤53.07) 01/23/2023
SURCHARGE FS 533.721 ¤2.58 01/23/2023
SURCHARGE - FS 468.631 ¤3.88 01/23/2023
SW ENG - FOUNDATION SURVEY ¤20.00 01/23/2023
SW ENG INSPECTION 80 ¤80.00 01/23/2023
SW ENG PRE APRON ¤30.00 01/23/2023
WATER- TURN ON ¤25.00 01/23/2023
ADJUSTMENT 50% (¤385.65) 01/23/2023
ADMINISTRATIVE RESIDENTIAL ¤30.00 01/23/2023
INSPECTION - RESIDENTIAL ¤577.50 01/23/2023
PLAN REVIEW - RESIDENTIAL ¤163.80 01/23/2023
CONNECTION FEES ¤1,166.26 01/23/2023
SW ENG - REVIEW 20 ¤20.00 01/23/2023
SW ENG RES REVIEW 200 ¤200.00 01/23/2023
TRANS IMPACT FEE ADMIN ¤52.92 01/23/2023
TRANS IMPACT FEE ADMIN (¤52.92) 01/23/2023
SEWER CREDIT (¤1,147.00) 01/23/2023
SEWER INSPECTION ¤25.00 01/23/2023
SEWER CAPITAL FACILITY ¤5,344.82 01/23/2023
WATER CAPITAL FACILITY FEE ¤3,923.88 01/23/2023
SITE PLAN 30 ¤30.00 01/23/2023
Fees Total Due: ¤0.00 Total Paid: ¤20,209.24