Permit #2023010286

Permit Details

Status: COED

Parcel Id: 07-11-31-7028-00140-0220
GARAGE: 262 sqft
CONDITIONED SPACE: 1298 sqft
OPENED PORCH (WITH ROOF) : 27 sqft
OPENED PORCH (WITH ROOF) : 50 sqft
Total Square Footage: 1637 sqft
Block: 00140
Subdivision: 2199 - SECTION 28-WYNNFIELD
Job Phone: 863-647-5815
Location Address: 41 PONCE DELEON DR
Type: DU - DUPLEX
Issue Date: 01/31/2023
NOC: RECORDED
Applicant name: MARK ALLAN HULBERT
Owner: HULBERT HOMES INC

Address

PO BOX 6254

LAKELAND, FL 33807

Lot: 0220
Contracted Stated Job Value: ¤300,000.00
Job Description: Duplex
Type: CN

Contractor

HULBERT HOMES INC
Status Location Address State License Number Phone
INACTIVE

PO BOX 6254

LAKELAND, FL 33813

CRC1331304 (Exp: 08/31/2026) 863-647-5815

Sub Contractors

MOISES MERINO DIAZ
Status Location Address State License Number Phone
ACTIVE

3104 ORANOLE ROAD

ORLANDO, FL 32810

CAC1820980 (Exp: 08/31/2026) 407-225-3149
STEPHEN COURTEAUX
Status Location Address State License Number Phone Fax
ACTIVE

85 North Yonge Street

Ormond Beach, FL 32174

EC13001748 (Exp: 08/31/2026) (386) 672-4900 386-676-7472
IAN ALAN BRENNER
Status Location Address Mailing Address State License Number Phone
ACTIVE

691 GARDEN COMMERCE PKWY

WINTER GARDEN, FL 34787

STE 170

WINTER GARDEN, FL 34787

CCC1331270 (Exp: 08/31/2026) 407-649-1333
ANTONIO VINCENZO DAHM
Status Location Address State License Number Phone
ACTIVE

10 RYBAR LANE

PALM COAST, FL 32164

CFC1429951 (Exp: 08/31/2026) 386-237-5692

Inspection History

Type Request Date Result Inspector
U-CROSS CONNECTION 08/25/2023 APPROVED - AS NOTED LFITZGERALD
Note: no irrigation-no cross connectin
BLD - BUILDING FINAL 08/22/2023 FINAL APPROVED KSANDOE
Note: 8/17/2023 - PREVIOUS INSPECTION NOTES 8/14/2023 - PREVIOUS INSPECTION NOTES Energy calcs have not been approved. Building Final inspection should should not be scheduled until all documents have been approved 8/11/2023 - PREVIOUS INSPECTION NOTES 8/11/23: Both Units: Energy Calcs still do not match for AHUs Unit B: Inspection now complete. 1). Water heater relief valve discharge pipe is too long per FBC P504.6. (1-1/2" minimum gap) 8/4/2023 - PREVIOUS INSPECTION NOTES 8/4/23: INSPECTION STOPPED! Please check both units for complete code compliance before calling back in for re-inspection. Unit A: Complete Inspection. 1). Missing supply register in Master Bedroom WIC highlighted on duct/register plan. 2). Energy Calcs do not match installed equipment. 3). Range anti-tip device is not anchored properly with 2 anchors into bottom plate or floor. One anchor is only into drywall. Also, hole in wall (Party wall) needs to be firestopped in approved manner. 4). Microwave exhaust is not sealed (firestopped) at the top in cabinet. Cannot verify if properly firestopped at drywall penetration. 5). Front door is missing door seals at the top and right jambs. 6). Hole in exterior wall at low voltage wires needs to be sealed. (Left side). 7). Front bathroom toilet seat is very loose. Unit B: Incomplete Inspection - Smokes & Bathrooms are the only items approved. 1). Energy Calcs do not match installed equipment. 2). Range anti-tip device not installed. 3). Dining Room outlet missing cover plate. 4). Kitchen counter has loose outlets - Need to check all. 5). Missing supply register in Master Bedroom WIC. 8/2/2023 - PREVIOUS INSPECTION NOTES Unit A. No working lights in hallway or front bedroom Multiple breakers tripped Stopped inspection. Please ensure property is ready for inspection 7/26/2023 - PREVIOUS INSPECTION NOTES House is locked. Need access for inspection FRC110.1 8-17-23 1. Firewall nailing needs to be approved before moving forward.
FIREWALL FINAL 08/21/2023 APPROVED KSANDOE
BLD - BUILDING FINAL 08/17/2023 Disapproved - NO FEE BTAYLOR
Note: 8/14/2023 - PREVIOUS INSPECTION NOTES Energy calcs have not been approved. Building Final inspection should should not be scheduled until all documents have been approved 8/11/2023 - PREVIOUS INSPECTION NOTES 8/11/23: Both Units: Energy Calcs still do not match for AHUs Unit B: Inspection now complete. 1). Water heater relief valve discharge pipe is too long per FBC P504.6. (1-1/2" minimum gap) 8/4/2023 - PREVIOUS INSPECTION NOTES 8/4/23: INSPECTION STOPPED! Please check both units for complete code compliance before calling back in for re-inspection. Unit A: Complete Inspection. 1). Missing supply register in Master Bedroom WIC highlighted on duct/register plan. 2). Energy Calcs do not match installed equipment. 3). Range anti-tip device is not anchored properly with 2 anchors into bottom plate or floor. One anchor is only into drywall. Also, hole in wall (Party wall) needs to be firestopped in approved manner. 4). Microwave exhaust is not sealed (firestopped) at the top in cabinet. Cannot verify if properly firestopped at drywall penetration. 5). Front door is missing door seals at the top and right jambs. 6). Hole in exterior wall at low voltage wires needs to be sealed. (Left side). 7). Front bathroom toilet seat is very loose. Unit B: Incomplete Inspection - Smokes & Bathrooms are the only items approved. 1). Energy Calcs do not match installed equipment. 2). Range anti-tip device not installed. 3). Dining Room outlet missing cover plate. 4). Kitchen counter has loose outlets - Need to check all. 5). Missing supply register in Master Bedroom WIC. 8/2/2023 - PREVIOUS INSPECTION NOTES Unit A. No working lights in hallway or front bedroom Multiple breakers tripped Stopped inspection. Please ensure property is ready for inspection 7/26/2023 - PREVIOUS INSPECTION NOTES House is locked. Need access for inspection FRC110.1 8-17-23 1. Firewall nailing needs to be approved before moving forward.
BLD - BUILDING FINAL 08/14/2023 Disapproved -FEE REQUIRED KSANDOE
Note: Energy calcs have not been approved. Building Final inspection should should not be scheduled until all documents have been approved 8/11/2023 - PREVIOUS INSPECTION NOTES 8/11/23: Both Units: Energy Calcs still do not match for AHUs Unit B: Inspection now complete. 1). Water heater relief valve discharge pipe is too long per FBC P504.6. (1-1/2" minimum gap) 8/4/2023 - PREVIOUS INSPECTION NOTES 8/4/23: INSPECTION STOPPED! Please check both units for complete code compliance before calling back in for re-inspection. Unit A: Complete Inspection. 1). Missing supply register in Master Bedroom WIC highlighted on duct/register plan. 2). Energy Calcs do not match installed equipment. 3). Range anti-tip device is not anchored properly with 2 anchors into bottom plate or floor. One anchor is only into drywall. Also, hole in wall (Party wall) needs to be firestopped in approved manner. 4). Microwave exhaust is not sealed (firestopped) at the top in cabinet. Cannot verify if properly firestopped at drywall penetration. 5). Front door is missing door seals at the top and right jambs. 6). Hole in exterior wall at low voltage wires needs to be sealed. (Left side). 7). Front bathroom toilet seat is very loose. Unit B: Incomplete Inspection - Smokes & Bathrooms are the only items approved. 1). Energy Calcs do not match installed equipment. 2). Range anti-tip device not installed. 3). Dining Room outlet missing cover plate. 4). Kitchen counter has loose outlets - Need to check all. 5). Missing supply register in Master Bedroom WIC. 8/2/2023 - PREVIOUS INSPECTION NOTES Unit A. No working lights in hallway or front bedroom Multiple breakers tripped Stopped inspection. Please ensure property is ready for inspection 7/26/2023 - PREVIOUS INSPECTION NOTES House is locked. Need access for inspection FRC110.1
BLD - BUILDING FINAL 08/11/2023 Disapproved - NO FEE RSIMS
Note: 8/11/23: Both Units: Energy Calcs still do not match for AHUs Unit B: Inspection now complete. 1). Water heater relief valve discharge pipe is too long per FBC P504.6. (1-1/2" minimum gap) 8/4/2023 - PREVIOUS INSPECTION NOTES 8/4/23: INSPECTION STOPPED! Please check both units for complete code compliance before calling back in for re-inspection. Unit A: Complete Inspection. 1). Missing supply register in Master Bedroom WIC highlighted on duct/register plan. 2). Energy Calcs do not match installed equipment. 3). Range anti-tip device is not anchored properly with 2 anchors into bottom plate or floor. One anchor is only into drywall. Also, hole in wall (Party wall) needs to be firestopped in approved manner. 4). Microwave exhaust is not sealed (firestopped) at the top in cabinet. Cannot verify if properly firestopped at drywall penetration. 5). Front door is missing door seals at the top and right jambs. 6). Hole in exterior wall at low voltage wires needs to be sealed. (Left side). 7). Front bathroom toilet seat is very loose. Unit B: Incomplete Inspection - Smokes & Bathrooms are the only items approved. 1). Energy Calcs do not match installed equipment. 2). Range anti-tip device not installed. 3). Dining Room outlet missing cover plate. 4). Kitchen counter has loose outlets - Need to check all. 5). Missing supply register in Master Bedroom WIC. 8/2/2023 - PREVIOUS INSPECTION NOTES Unit A. No working lights in hallway or front bedroom Multiple breakers tripped Stopped inspection. Please ensure property is ready for inspection 7/26/2023 - PREVIOUS INSPECTION NOTES House is locked. Need access for inspection FRC110.1
BLD - BUILDING FINAL 08/04/2023 Disapproved -FEE REQUIRED RSIMS
Note: 8/4/23: INSPECTION STOPPED! Please check both units for complete code compliance before calling back in for re-inspection. Unit A: Complete Inspection. 1). Missing supply register in Master Bedroom WIC highlighted on duct/register plan. 2). Energy Calcs do not match installed equipment. 3). Range anti-tip device is not anchored properly with 2 anchors into bottom plate or floor. One anchor is only into drywall. Also, hole in wall (Party wall) needs to be firestopped in approved manner. 4). Microwave exhaust is not sealed (firestopped) at the top in cabinet. Cannot verify if properly firestopped at drywall penetration. 5). Front door is missing door seals at the top and right jambs. 6). Hole in exterior wall at low voltage wires needs to be sealed. (Left side). 7). Front bathroom toilet seat is very loose. Unit B: Incomplete Inspection - Smokes & Bathrooms are the only items approved. 1). Energy Calcs do not match installed equipment. 2). Range anti-tip device not installed. 3). Dining Room outlet missing cover plate. 4). Kitchen counter has loose outlets - Need to check all. 5). Missing supply register in Master Bedroom WIC. 8/2/2023 - PREVIOUS INSPECTION NOTES Unit A. No working lights in hallway or front bedroom Multiple breakers tripped Stopped inspection. Please ensure property is ready for inspection 7/26/2023 - PREVIOUS INSPECTION NOTES House is locked. Need access for inspection FRC110.1
ROW - FINAL INSPECTION 08/03/2023 FINAL APPROVED PFLANAGAN
Note: At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved. ----------------------------------------------------------------------------------- 7/26/2023 - PREVIOUS INSPECTION NOTES 07/26/23 CULVERT IS FULL OF DIRT AND SILT, WHOLE PIPE NEEDS TO BE CLEANED OUT. IT IS NOT ALLOWING WATER TO DRAIN TO CITY DITCH. 43 IS FULL OF DIRT AS WELL AND NEEDS TO BE FULLY CLEANED OUT TO ALLOW SWALE TO DRAIN TO DITCH. I AM NOT GOING TO FEE YOU TODAY. MAKE THE CORRECTION PLEASE.
U -UTILITY RESIDENTIAL FINAL 08/03/2023 FINAL APPROVED DHANEY
Note: 7/26/2023 - PREVIOUS INSPECTION NOTES need sod around water mete boxes/2nd sewer clean out cap too high-need to be flush like 1st clean out is
BLD - BUILDING FINAL 08/02/2023 Disapproved -FEE REQUIRED KSANDOE
Note: Unit A. No working lights in hallway or front bedroom Multiple breakers tripped Stopped inspection. Please ensure property is ready for inspection 7/26/2023 - PREVIOUS INSPECTION NOTES House is locked. Need access for inspection FRC110.1
BLD - BUILDING FINAL 07/26/2023 Disapproved -FEE REQUIRED KSANDOE
Note: House is locked. Need access for inspection FRC110.1
ROW - FINAL INSPECTION 07/26/2023 Disapproved - NO FEE FSLADISH
Note: 07/26/23 CULVERT IS FULL OF DIRT AND SILT, WHOLE PIPE NEEDS TO BE CLEANED OUT. IT IS NOT ALLOWING WATER TO DRAIN TO CITY DITCH. 43 IS FULL OF DIRT AS WELL AND NEEDS TO BE FULLY CLEANED OUT TO ALLOW SWALE TO DRAIN TO DITCH. I AM NOT GOING TO FEE YOU TODAY. MAKE THE CORRECTION PLEASE.
U -UTILITY RESIDENTIAL FINAL 07/26/2023 Disapproved -FEE REQUIRED LFITZGERALD
Note: need sod around water mete boxes/2nd sewer clean out cap too high-need to be flush like 1st clean out is
ROW- FINAL SURVEY/GRADING CERTIFICATION 07/24/2023 APPROVED PFLANAGAN
Note: At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved. ---------------------------------------------------------------------------------------- 7/13/2023 - PREVIOUS INSPECTION NOTES 07/13/23 you submitted the wrong survey. this survey is for 43 Ponce Deleon not 41 Ponce deleon. 7/11/2023 - PREVIOUS INSPECTION NOTES 07/11/23 NEED TO SHOW ELEVATIONS ON RIGHT SIDE PROPERTY LINE ON A 20' GRID. WHAT YOU ARE SHOWING WITH LIMITED ELEVATION SHOTS IS FLAT DRAINAGE FOR MORE THAN 20'. YOUR SITE PLANE PROPOSES INSIDE PROPERTY LINE DRAINAGE BETWEEN THE HOMES. THIS SHOULD BE A COMMON SWALE WITH ADJOINING PROPERTY. NEED 10' OFFSET SHOTS FROM ADJOINING PROPERTY. Elevations every 20 ft. on the property line Sec 300.01D1 Sec 300.01D1 The elevations along all property lines must be at a minimum of 20 foot intervals. Propose Drainage Pattern Section 300.01c(5) Section 300.01c(5).The proposed elevations shall be shown at all locations of existing elevations per the topographic survey. There must be sufficient elevation shots to indicate the proposed drainage pattern. Elevations every 20 ft off the property lines Sec 300.01D2 Sec 300.01 D2 The elevations on all adjacent identified (e.g. vacant or improved etc.) properties at a minimum of 20 foot intervals on a 10 foot offset outside the property lines. Rear Yard Drainage Sec 300.01(4,5,6) Sec 300.01(4,5,6) The tolerance along side lot lines is no more than 20 feet flat, with positive fall on each side.Positive fall is considered to be 0.10 feet in 20 feet.The minimum fall from the rear property line to the front is 0.50 feet. __________________________________________________________________________________________________________________________ 7/5/2023 - PREVIOUS INSPECTION NOTES 07/05/23 NEED TO SHOW POSITIVE DRAINAGE FROM REAR TO FRONT OF PROPERTY NEED TO LIST ALL FFE FOR ADJACENT PROPERTIES. NEED TO SHOW ALL CULVERT ELEVATIONS WITHIN 130 FT OF LOT LINE. Lot must drain. Section 300.01 (A)(1)(C)(6) Section 300.01 (A)(1)(C)(6). Unless specifically stated the subject lot must drain from back to front or a portion may be drained to an adjacent City drainage feature. (B) ________________________________________________________________________________________________________________________ 6/22/2023 - PREVIOUS INSPECTION NOTES 1) Sec 300.01 D2 The elevations on all adjacent identified (e.g. vacant or improved etc.) properties at a minimum of 20 foot intervals on a 10 foot offset outside the property lines. All undeveloped properties must be properly identified on the site plan and Final Survey. There must be sufficient elevation shots to indicate the intended drainage pattern. 2) Sec 300.01 D3 The interior elevations at no greater than a 20 foot grid. There must be sufficient elevation shots to indicate the intended drainage pattern. Don't have sufficient elevation to determind if road side swale flows in right direction.
ROW FIELD SURVEY /GRADING CERTIFICATION 07/24/2023 APPROVED PFLANAGAN
Note: At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved.
ROW - FINAL APRON (AFTER POUR) 07/24/2023 APPROVED PFLANAGAN
Note: At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved.
ROW- FINAL SURVEY/GRADING CERTIFICATION 07/13/2023 Disapproved - NO FEE FSLADISH
Note: 07/13/23 you submitted the wrong survey. this survey is for 43 Ponce Deleon not 41 Ponce deleon. 7/11/2023 - PREVIOUS INSPECTION NOTES 07/11/23 NEED TO SHOW ELEVATIONS ON RIGHT SIDE PROPERTY LINE ON A 20' GRID. WHAT YOU ARE SHOWING WITH LIMITED ELEVATION SHOTS IS FLAT DRAINAGE FOR MORE THAN 20'. YOUR SITE PLANE PROPOSES INSIDE PROPERTY LINE DRAINAGE BETWEEN THE HOMES. THIS SHOULD BE A COMMON SWALE WITH ADJOINING PROPERTY. NEED 10' OFFSET SHOTS FROM ADJOINING PROPERTY. Elevations every 20 ft. on the property line Sec 300.01D1 Sec 300.01D1 The elevations along all property lines must be at a minimum of 20 foot intervals. Propose Drainage Pattern Section 300.01c(5) Section 300.01c(5).The proposed elevations shall be shown at all locations of existing elevations per the topographic survey. There must be sufficient elevation shots to indicate the proposed drainage pattern. Elevations every 20 ft off the property lines Sec 300.01D2 Sec 300.01 D2 The elevations on all adjacent identified (e.g. vacant or improved etc.) properties at a minimum of 20 foot intervals on a 10 foot offset outside the property lines. Rear Yard Drainage Sec 300.01(4,5,6) Sec 300.01(4,5,6) The tolerance along side lot lines is no more than 20 feet flat, with positive fall on each side.Positive fall is considered to be 0.10 feet in 20 feet.The minimum fall from the rear property line to the front is 0.50 feet. __________________________________________________________________________________________________________________________ 7/5/2023 - PREVIOUS INSPECTION NOTES 07/05/23 NEED TO SHOW POSITIVE DRAINAGE FROM REAR TO FRONT OF PROPERTY NEED TO LIST ALL FFE FOR ADJACENT PROPERTIES. NEED TO SHOW ALL CULVERT ELEVATIONS WITHIN 130 FT OF LOT LINE. Lot must drain. Section 300.01 (A)(1)(C)(6) Section 300.01 (A)(1)(C)(6). Unless specifically stated the subject lot must drain from back to front or a portion may be drained to an adjacent City drainage feature. (B) ________________________________________________________________________________________________________________________ 6/22/2023 - PREVIOUS INSPECTION NOTES 1) Sec 300.01 D2 The elevations on all adjacent identified (e.g. vacant or improved etc.) properties at a minimum of 20 foot intervals on a 10 foot offset outside the property lines. All undeveloped properties must be properly identified on the site plan and Final Survey. There must be sufficient elevation shots to indicate the intended drainage pattern. 2) Sec 300.01 D3 The interior elevations at no greater than a 20 foot grid. There must be sufficient elevation shots to indicate the intended drainage pattern. Don't have sufficient elevation to determind if road side swale flows in right direction.
ROW- FINAL SURVEY/GRADING CERTIFICATION 07/11/2023 Disapproved - NO FEE FSLADISH
Note: 07/11/23 NEED TO SHOW ELEVATIONS ON RIGHT SIDE PROPERTY LINE ON A 20' GRID. WHAT YOU ARE SHOWING WITH LIMITED ELEVATION SHOTS IS FLAT DRAINAGE FOR MORE THAN 20'. YOUR SITE PLANE PROPOSES INSIDE PROPERTY LINE DRAINAGE BETWEEN THE HOMES. THIS SHOULD BE A COMMON SWALE WITH ADJOINING PROPERTY. NEED 10' OFFSET SHOTS FROM ADJOINING PROPERTY. Elevations every 20 ft. on the property line Sec 300.01D1 Sec 300.01D1 The elevations along all property lines must be at a minimum of 20 foot intervals. Propose Drainage Pattern Section 300.01c(5) Section 300.01c(5).The proposed elevations shall be shown at all locations of existing elevations per the topographic survey. There must be sufficient elevation shots to indicate the proposed drainage pattern. Elevations every 20 ft off the property lines Sec 300.01D2 Sec 300.01 D2 The elevations on all adjacent identified (e.g. vacant or improved etc.) properties at a minimum of 20 foot intervals on a 10 foot offset outside the property lines. Rear Yard Drainage Sec 300.01(4,5,6) Sec 300.01(4,5,6) The tolerance along side lot lines is no more than 20 feet flat, with positive fall on each side.Positive fall is considered to be 0.10 feet in 20 feet.The minimum fall from the rear property line to the front is 0.50 feet. __________________________________________________________________________________________________________________________ 7/5/2023 - PREVIOUS INSPECTION NOTES 07/05/23 NEED TO SHOW POSITIVE DRAINAGE FROM REAR TO FRONT OF PROPERTY NEED TO LIST ALL FFE FOR ADJACENT PROPERTIES. NEED TO SHOW ALL CULVERT ELEVATIONS WITHIN 130 FT OF LOT LINE. Lot must drain. Section 300.01 (A)(1)(C)(6) Section 300.01 (A)(1)(C)(6). Unless specifically stated the subject lot must drain from back to front or a portion may be drained to an adjacent City drainage feature. (B) ________________________________________________________________________________________________________________________ 6/22/2023 - PREVIOUS INSPECTION NOTES 1) Sec 300.01 D2 The elevations on all adjacent identified (e.g. vacant or improved etc.) properties at a minimum of 20 foot intervals on a 10 foot offset outside the property lines. All undeveloped properties must be properly identified on the site plan and Final Survey. There must be sufficient elevation shots to indicate the intended drainage pattern. 2) Sec 300.01 D3 The interior elevations at no greater than a 20 foot grid. There must be sufficient elevation shots to indicate the intended drainage pattern. Don't have sufficient elevation to determind if road side swale flows in right direction.
ROW- FINAL SURVEY/GRADING CERTIFICATION 07/05/2023 Disapproved - NO FEE FSLADISH
Note: 07/05/23 NEED TO SHOW POSITIVE DRAINAGE FROM REAR TO FRONT OF PROPERTY NEED TO LIST ALL FFE FOR ADJACENT PROPERTIES. NEED TO SHOW ALL CULVERT ELEVATIONS WITHIN 130 FT OF LOT LINE. Lot must drain. Section 300.01 (A)(1)(C)(6) Section 300.01 (A)(1)(C)(6). Unless specifically stated the subject lot must drain from back to front or a portion may be drained to an adjacent City drainage feature. (B) ________________________________________________________________________________________________________________________ 6/22/2023 - PREVIOUS INSPECTION NOTES 1) Sec 300.01 D2 The elevations on all adjacent identified (e.g. vacant or improved etc.) properties at a minimum of 20 foot intervals on a 10 foot offset outside the property lines. All undeveloped properties must be properly identified on the site plan and Final Survey. There must be sufficient elevation shots to indicate the intended drainage pattern. 2) Sec 300.01 D3 The interior elevations at no greater than a 20 foot grid. There must be sufficient elevation shots to indicate the intended drainage pattern. Don't have sufficient elevation to determind if road side swale flows in right direction.
ELECTRIC - EARLY POWER 06/26/2023 APPROVED - AS NOTED KSANDOE
Note: Emailed FPL @ 1314. Release Power 6/20/2023 - PREVIOUS INSPECTION NOTES Protection for ground. Ground wire needs to be protected Disconnect for AC cannot be behind unit Inspector Notes from Inspection 2170 Emailed FPL @ 1247. Release Power
ROW- FINAL SURVEY/GRADING CERTIFICATION 06/22/2023 Disapproved - NO FEE PFLANAGAN
Note: 1) Sec 300.01 D2 The elevations on all adjacent identified (e.g. vacant or improved etc.) properties at a minimum of 20 foot intervals on a 10 foot offset outside the property lines. All undeveloped properties must be properly identified on the site plan and Final Survey. There must be sufficient elevation shots to indicate the intended drainage pattern. 2) Sec 300.01 D3 The interior elevations at no greater than a 20 foot grid. There must be sufficient elevation shots to indicate the intended drainage pattern. Don't have sufficient elevation to determind if road side swale flows in right direction.
ELECTRIC - EARLY POWER 06/20/2023 Disapproved - NO FEE KSANDOE
Note: Protection for ground. Ground wire needs to be protected Disconnect for AC cannot be behind unit Inspector Notes from Inspection 2170 Emailed FPL @ 1247. Release Power
ROW- PRE-APRON (PRE-POUR) 05/22/2023 Disapproved - NO FEE GBERTOLA
Note: 5/22/23= idon't know why this is approved inspector wasn't there. I DID ADD AGAIN ANOTHER PRE POUR INSPECTION 5/18/2023 - PREVIOUS INSPECTION NOTES 5/18/23= NEED TO HAVE POSITIVE FLOW TO THE FRONT. FROM BOTH SIDE OF THE APRON TO THE DRIVEWAY WATER IS GOING BACKWARD. CULVERT PIPE IS GOOD +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 5/17/2023 - PREVIOUS INSPECTION NOTES CANCELLED BY CM DO TO FROMS ARE NOT COMPLETED -------------------------------------------------------------------------- 5/16/2023 - PREVIOUS INSPECTION NOTES NOT READY
ROW- PRE-APRON (PRE-POUR) 05/22/2023 APPROVED - AS NOTED GBERTOLA
Note: 5/22/2023= CORRECTION WERE MADE AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS BEFORE POURING. MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 5/22/23= idon't know why this is approved inspector wasn't there. I DID ADD AGAIN ANOTHER PRE POUR INSPECTION 5/18/2023 - PREVIOUS INSPECTION NOTES 5/18/23= NEED TO HAVE POSITIVE FLOW TO THE FRONT. FROM BOTH SIDE OF THE APRON TO THE DRIVEWAY WATER IS GOING BACKWARD. CULVERT PIPE IS GOOD +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 5/17/2023 - PREVIOUS INSPECTION NOTES CANCELLED BY CM DO TO FROMS ARE NOT COMPLETED -------------------------------------------------------------------------- 5/16/2023 - PREVIOUS INSPECTION NOTES NOT READY
ROW- PRE-APRON (PRE-POUR) 05/18/2023 Disapproved - NO FEE GBERTOLA
Note: 5/18/23= NEED TO HAVE POSITIVE FLOW TO THE FRONT. FROM BOTH SIDE OF THE APRON TO THE DRIVEWAY WATER IS GOING BACKWARD. CULVERT PIPE IS GOOD +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 5/17/2023 - PREVIOUS INSPECTION NOTES CANCELLED BY CM DO TO FROMS ARE NOT COMPLETED -------------------------------------------------------------------------- 5/16/2023 - PREVIOUS INSPECTION NOTES NOT READY
ROW- PRE-APRON (PRE-POUR) 05/17/2023 CANCELLED BY APPLICANT PFLANAGAN
Note: CANCELLED BY CM DO TO FROMS ARE NOT COMPLETED -------------------------------------------------------------------------- 5/16/2023 - PREVIOUS INSPECTION NOTES NOT READY
ROW- PRE-APRON (PRE-POUR) 05/16/2023 CANCELLED BY APPLICANT PFLANAGAN
Note: NOT READY
U - SEWER TIE IN 05/09/2023 APPROVED MGIBSON
Note: 5/5/2023 - PREVIOUS INSPECTION NOTES Unable to view connections. Trench flooded 5/4/2023 - PREVIOUS INSPECTION NOTES Trenches flooded. Plumbing not holding water. Unable to see connections
GRAVITY SEWER TEST 05/08/2023 Disapproved - NO FEE KSANDOE
Note: Still not holding water. 5/5/2023 - PREVIOUS INSPECTION NOTES Not holding water. Test failed New inspection due to canceled inspection New inspection due to canceled inspection 5/4/2023 - PREVIOUS INSPECTION NOTES Trenches flooded. Plumbing not holding water. Unable to see connections
GRAVITY SEWER TEST 05/08/2023 APPROVED KSANDOE
Note: 5/8/2023 - PREVIOUS INSPECTION NOTES Still not holding water. 5/5/2023 - PREVIOUS INSPECTION NOTES Not holding water. Test failed New inspection due to canceled inspection New inspection due to canceled inspection 5/4/2023 - PREVIOUS INSPECTION NOTES Trenches flooded. Plumbing not holding water. Unable to see connections
GRAVITY SEWER TEST 05/05/2023 CANCELLED BY APPLICANT WEB
Note: 5/4/2023 - PREVIOUS INSPECTION NOTES Trenches flooded. Plumbing not holding water. Unable to see connections
GRAVITY SEWER TEST 05/05/2023 CANCELLED BY APPLICANT WEB
Note: New inspection due to canceled inspection 5/4/2023 - PREVIOUS INSPECTION NOTES Trenches flooded. Plumbing not holding water. Unable to see connections
GRAVITY SEWER TEST 05/05/2023 Disapproved -FEE REQUIRED KSANDOE
Note: Not holding water. Test failed New inspection due to canceled inspection New inspection due to canceled inspection 5/4/2023 - PREVIOUS INSPECTION NOTES Trenches flooded. Plumbing not holding water. Unable to see connections
U - SEWER TIE IN 05/05/2023 Disapproved - NO FEE KSANDOE
Note: Unable to view connections. Trench flooded 5/4/2023 - PREVIOUS INSPECTION NOTES Trenches flooded. Plumbing not holding water. Unable to see connections
U - SEWER TIE IN 05/04/2023 Disapproved - NO FEE KSANDOE
Note: Trenches flooded. Plumbing not holding water. Unable to see connections
GRAVITY SEWER TEST 05/04/2023 Disapproved - NO FEE KSANDOE
Note: Trenches flooded. Plumbing not holding water. Unable to see connections
PEP TANK INSTALLATION REQUEST 04/19/2023 APPROVED TSCHWEERS
INSULATION 04/10/2023 APPROVED KSANDOE
Note: Inspector Notes from Inspection 2420 Overhead service wire needs to be sunlight resistant Will check front doors at insulation inspection
ELECTRIC TEMP POLE 04/10/2023 APPROVED - AS NOTED KSANDOE
Note: Emailed FPL @ 1247. Release Power
ALL ROUGH 03/31/2023 APPROVED - AS NOTED KSANDOE
Note: Overhead service wire needs to be sunlight resistant Will check front doors at insulation inspection
LATH/BRICK/ WATER BARRIER 03/30/2023 APPROVED KSANDOE
FIREWALL DRYWALL NAILING 03/22/2023 CANCELLED BY INSPECTOR KSANDOE
ROOF SHEATHING / BRACES/TIES/DOWN CELL 03/21/2023 APPROVED KSANDOE
Note: 3/15/2023 - PREVIOUS INSPECTION NOTES 3/9/2023 - PREVIOUS INSPECTION NOTES Still missing requested details Framing crews working, job incomplete Still missing anchors 3/7/2023 - PREVIOUS INSPECTION NOTES Roof was walked sheating fastening passes inspection. Approved to cover roof. Fire rated plywood is in place. Down cells pass inspection. 1. Please have a truss drawing and engineering packet onsite for inspection. 2. The bearing walls in both units have not been built as per detials, missing anchors. 3. Please provide a detail on how the bottom plate of the firewall is to be attached to the CMU wall. Inspection was stopped due to missing drawing and multiple missing anchors. A full inspection still needed.
ROOF VALLEY & METAL 03/15/2023 APPROVED KSANDOE
ROOF SHEATHING / BRACES/TIES/DOWN CELL 03/15/2023 CANCELLED BY APPLICANT KSANDOE
Note: 3/9/2023 - PREVIOUS INSPECTION NOTES Still missing requested details Framing crews working, job incomplete Still missing anchors 3/7/2023 - PREVIOUS INSPECTION NOTES Roof was walked sheating fastening passes inspection. Approved to cover roof. Fire rated plywood is in place. Down cells pass inspection. 1. Please have a truss drawing and engineering packet onsite for inspection. 2. The bearing walls in both units have not been built as per detials, missing anchors. 3. Please provide a detail on how the bottom plate of the firewall is to be attached to the CMU wall. Inspection was stopped due to missing drawing and multiple missing anchors. A full inspection still needed.
ROOF SHEATHING / BRACES/TIES/DOWN CELL 03/09/2023 Disapproved -FEE REQUIRED KSANDOE
Note: Still missing requested details Framing crews working, job incomplete Still missing anchors 3/7/2023 - PREVIOUS INSPECTION NOTES Roof was walked sheating fastening passes inspection. Approved to cover roof. Fire rated plywood is in place. Down cells pass inspection. 1. Please have a truss drawing and engineering packet onsite for inspection. 2. The bearing walls in both units have not been built as per detials, missing anchors. 3. Please provide a detail on how the bottom plate of the firewall is to be attached to the CMU wall. Inspection was stopped due to missing drawing and multiple missing anchors. A full inspection still needed.
WALL SHEATHING 03/07/2023 APPROVED JWALKER
ROOF SHEATHING / BRACES/TIES/DOWN CELL 03/07/2023 Disapproved - NO FEE JWALKER
Note: Roof was walked sheating fastening passes inspection. Approved to cover roof. Fire rated plywood is in place. Down cells pass inspection. 1. Please have a truss drawing and engineering packet onsite for inspection. 2. The bearing walls in both units have not been built as per detials, missing anchors. 3. Please provide a detail on how the bottom plate of the firewall is to be attached to the CMU wall. Inspection was stopped due to missing drawing and multiple missing anchors. A full inspection still needed.
TIE BEAM / LINTEL 02/28/2023 APPROVED KSANDOE
FOUND SURVEY APPROVED (OFFICE) 02/23/2023 APPROVED TBAKER
WATER METER INSTALLATION REQUEST 02/16/2023 APPROVED TSCHWEERS
MONOLITHIC SLAB 02/14/2023 APPROVED KSANDOE
PLUMBING 1ST ROUGH UNDERGROUND 02/10/2023 CANCELLED BY INSPECTOR LMUSGROVE
Note: NOC needs to be corrected and re-recorded
PLUMBING 1ST ROUGH UNDERGROUND 02/10/2023 APPROVED TSTAUFFACHER

Review History

Department Status Date In Date Out
MECH COMPLETE 08/15/2023 08/16/2023
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
MECH HOLD 08/14/2023 08/15/2023
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Energy Calcs need to be signed by the owner/ owner agent below the preparer per R103.1.1.2 FBC Energy Conservation 2020 7Th edition
MECH COMPLETE 07/10/2023 07/10/2023
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
MECH HOLD 06/30/2023 07/06/2023
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM 1. Energy Calcs need to be signed by the owner/ owner agent below the preparer per R103.1.1.2 FBC Energy Conservation 2020 7Th edition 2. Provide adjacent wall insulation and type on Energy calcs. 3. TMY site on Energy calcs needs to be Daytona Beach
BLD COMPLETE 03/20/2023 03/20/2023
Note: Released By: PATRICK BUCKLEY - (386)986-3786 - PBUCKLEY@PALMCOASTGOV.COM
BLD COMPLETE 03/20/2023 03/20/2023
Note: Released By: PATRICK BUCKLEY - (386)986-3786 - PBUCKLEY@PALMCOASTGOV.COM
BLD HOLD 03/14/2023 03/15/2023
Note: Held By: PATRICK BUCKLEY - (386)986-3786 - PBUCKLEY@PALMCOASTGOV.COM Submitted detail does not match actual conditions. Detail shows shaft liner firewall from foundation through a two story home to roof deck of roofs of different height. Actual conditions indicate a one story home with a CMU wall to the ceiling height. Firewall detail would only need to be from top of CMU wall to underside of roof sheathing. Inspector has indicated something entirely different is being constructed in the field. Detail needs to match actual construction.
BLD HOLD 03/09/2023 03/09/2023
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Plans submitted need to be digitally signed and sealed.
ENGIN1 COMPLETE 02/23/2023 02/23/2023
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON COMPLETE 02/23/2023 02/23/2023
Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM
BLD COMPLETE 02/15/2023 02/22/2023
Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM
BADMIN INFORMATION 02/08/2023 02/08/2023
Note: Marked INFORMATION By: BARBIE BEMBRY - (386)986-3780 - BUILDINGDIVISION@PALMCOASTGOV.COM Rename file to notice of commencement.
BADMIN COMPLETE 02/08/2023 02/08/2023
Note: Released By: SCOTT THOMAS - - STHOMAS@PALMCOASTGOV.COM NOC MISSING YEAR AT BOTTOM BY NOTARY. MUST BE RE-RECORDED WITH DIFFERENT INSTRUMENT # (2023004991) TO REFLECT OFFICIAL RECORDING WITH FLAGLER COUNTY CLERK OF COURT RECORDS
BLD COMPLETE 02/01/2023 02/07/2023
Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM
ELEC COMPLETE 02/01/2023 02/01/2023
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
BLD COMPLETE 01/31/2023 01/31/2023
Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM
ZON COMPLETE 01/25/2023 01/25/2023
Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM EXTERIOR STONE REMOVED
MECH COMPLETE 01/25/2023 01/26/2023
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
SWALE COMPLETE 01/18/2023 04/20/2023
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
BLD COMPLETE 01/17/2023 01/18/2023
Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM
MECH HOLD 01/17/2023 01/17/2023
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM 1. Provide details wall insulation. Energy Calcs show block with R13. 3/4 inch foam board is R5 typically. Show insulation on plans. 2. Provide Energy calcs for both sides of duplex
BLD COMPLETE 01/17/2023 01/18/2023
Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM
SW1 COMPLETE 01/17/2023 01/25/2023
Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM
ZON COMPLETE 01/17/2023 01/17/2023
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
ENGIN1 COMPLETE 01/17/2023 01/18/2023
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ELEC COMPLETE 01/17/2023 01/18/2023
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
MECH HOLD 01/12/2023 01/12/2023
Note: Held By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM All comments below per the 2020 Florida Building Code REVIEW COMMENTS: 1. Chosen equipment on heatload exceeds the maximum of 1.15 times the load calculated per R403.7.1.2.1 FBC Energy Conservation 2020 7TH Edition 2. Direction house faces on Energy Calcs does not match the site plan. Revise to match per R405.4.2.1 FBC Energy Conservation 2020 7Th Edition 3. Duct layout needs to show duct sizing per manual D and returns in all areas 4. Duct layout needs to be signed by the AC contractor per 107.1 FBC Residential 2020 7th Edition 5. Design location and TMY site on Energy Calcs needs to be Daytona Beach 6. Design location on heatload needs to be Daytona Beach. 7. Square footage on energy calcs does not match the House plans 8. Provide Heatload for both sides of duplex 9. Proposed windows are aluminum. Energy Forms show vinyl windows to be installed. A revision to the proposed approval or energy forms is required to reference the correct windows to be installed.
BLD HOLD 01/06/2023 01/12/2023
Note: Held By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM All comments below per the 2020 Florida Building Code REVIEW COMMENTS: 1. Details A5 and A6 on Sheet SD.2 reference a fire rated wall. Provide details and UL listing for proposed fire rated wall.
CUSVC COMPLETE 01/06/2023 01/06/2023
Note: Released By: HALEIGH HAND - -
ELEC HOLD 01/06/2023 01/06/2023
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM Submit electric load calcs
ENGIN1 HOLD 01/06/2023 01/06/2023
Note: Held By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM Survey elevations need to be carried out to the nearest hundredth of a foot.
LOCATE COMPLETE 01/06/2023 01/10/2023
Note: Released By: CANDACE STONE - - CSTONE@PALMCOASTGOV.COM
MECH HOLD 01/06/2023 01/09/2023
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM 1. Chosen equipment on heatload exceeds the maximum of 1.15 times the load calculated.per R403.7.1.2.1 FBC Energy Conservation 2020 7TH Edition 2. Direction house faces on Energy Calcs does not match the site plan. Revise to match per R405.4.2.1 FBC Energy Conservation 2020 7Th Edition 3. Duct layout needs to show duct sizing per manual D and returns in all areas 4. Duct layout needs to be signed by the AC contractor per 107.1 FBC Residential 2020 7th Edition 5. Design location and TMY site on Energy Calcs needs to be Daytona Beach 6. Design location on heatload needs to be Daytona Beach. 7. Square footage on energy calcs does not match the House plans 8. Provide Heatload for both sides of duplex
SW1 HOLD 01/06/2023 01/13/2023
Note: Held By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM NEED TO HAVE PROPOSED ELEVATIONS ON ALL FOUR CORNERS OF THE HOUSE SO WE CAN DETERMINE IF YOU HAVE 4" BELOW FFE
ZON HOLD 01/06/2023 01/06/2023
Note: Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM Please provide total driveway width at the widest point. Cannot exceed 40ft total landscape plan missing from submittal

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
PLAN REVIEW - REVISION ¤32.50 08/23/2023
PLAN REVIEW - REVISION ¤32.50 08/23/2023
PLAN REVIEW - REVISION ¤65.00 08/23/2023
PLAN REVIEW - REVISION ¤32.50 08/23/2023
REINSPECTION RESIDENTIAL ¤40.00 08/23/2023
REINSPECTION RESIDENTIAL ¤40.00 08/23/2023
REINSPECTION RESIDENTIAL ¤40.00 08/23/2023
REINSPECTION RESIDENTIAL ¤40.00 08/23/2023
REINSPECTION RESIDENTIAL ¤40.00 08/23/2023
REINSPECTION RESIDENTIAL ¤40.00 08/23/2023
CONTRACTOR CHANGE ¤20.00 08/23/2023
REINSPECTION FEE ¤40.00 08/23/2023
SURCHARGE FS 533.721 ¤3.49 01/31/2023
SURCHARGE - FS 468.631 ¤5.24 01/31/2023
SW ENG - FOUNDATION SURVEY ¤20.00 01/31/2023
SW ENG INSPECTION 80 ¤80.00 01/31/2023
SW ENG PRE APRON ¤30.00 01/31/2023
SW ENG - REVIEW 20 ¤20.00 01/31/2023
SW ENG RES REVIEW 200 ¤200.00 01/31/2023
TRANS IMPACT FEE ADMIN ¤84.36 01/31/2023
TRANS IMPACT FEE ADMIN (¤84.36) 01/31/2023
SEWER CREDIT (¤1,300.00) 01/31/2023
SEWER INSPECTION ¤25.00 01/31/2023
SEWER CAPITAL FACILITY ¤10,689.64 01/31/2023
WATER CAPITAL FACILITY FEE ¤7,847.76 01/31/2023
SITE PLAN 30 ¤30.00 01/31/2023
WATER- TURN ON ¤50.00 01/31/2023
ADJUSTMENT 50% (¤544.50) 01/31/2023
ADMINISTRATIVE RESIDENTIAL ¤30.00 01/31/2023
INSPECTION - RESIDENTIAL ¤825.00 01/31/2023
PLAN REVIEW - RESIDENTIAL ¤234.00 01/31/2023
FIRE IMPACT FEE ADMIN ¤25.23 01/31/2023
FIRE IMPACT FEE ADMIN (¤25.23) 01/31/2023
FC IMPACT FEE EMS ¤124.00 01/31/2023
IMPACT FEE FIRE ¤841.04 01/31/2023
FC IMPACT FEE LAW ENFORCEMENT ¤436.00 01/31/2023
FC IMPACT FEE LIBRARY ¤536.00 01/31/2023
IMPACT FEE PARKS ¤3,538.30 01/31/2023
IMPACT FEE SCHOOL ¤10,900.00 01/31/2023
IMPACT FEE TRANSPORTATION ¤2,812.00 01/31/2023
WATER -IRRIGATION INSPECTION ¤50.00 01/31/2023
PARKS IMPACT FEE ADMIN ¤106.15 01/31/2023
PARKS IMPACT FEE ADMIN (¤106.15) 01/31/2023
CONNECTION FEES ¤2,332.52 01/31/2023
Fees Total Due: ¤0.00 Total Paid: ¤40,277.99