Permit #2023010286
Permit Details
Status: COED
| Parcel Id: 07-11-31-7028-00140-0220 |
| GARAGE: 262 sqft |
| CONDITIONED SPACE: 1298 sqft |
| OPENED PORCH (WITH ROOF) : 27 sqft |
| OPENED PORCH (WITH ROOF) : 50 sqft |
| Total Square Footage: 1637 sqft |
| Block: 00140 |
| Subdivision: 2199 - SECTION 28-WYNNFIELD |
| Job Phone: 863-647-5815 |
| Location Address: 41 PONCE DELEON DR |
| Type: DU - DUPLEX |
| Issue Date: 01/31/2023 |
| NOC: RECORDED |
| Applicant name: MARK ALLAN HULBERT |
| Owner: HULBERT HOMES INC |
|
Address PO BOX 6254 LAKELAND, FL 33807 |
| Lot: 0220 |
| Contracted Stated Job Value: ¤300,000.00 |
| Job Description: Duplex |
| Type: CN |
Contractor
HULBERT HOMES INC
| Status | Location Address | State License Number | Phone |
| INACTIVE |
PO BOX 6254 LAKELAND, FL 33813 |
CRC1331304 (Exp: 08/31/2026) | 863-647-5815 |
Sub Contractors
MOISES MERINO DIAZ
| Status | Location Address | State License Number | Phone |
| ACTIVE |
3104 ORANOLE ROAD ORLANDO, FL 32810 |
CAC1820980 (Exp: 08/31/2026) | 407-225-3149 |
STEPHEN COURTEAUX
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
85 North Yonge Street Ormond Beach, FL 32174 |
EC13001748 (Exp: 08/31/2026) | (386) 672-4900 | 386-676-7472 |
IAN ALAN BRENNER
| Status | Location Address | Mailing Address | State License Number | Phone |
| ACTIVE |
691 GARDEN COMMERCE PKWY WINTER GARDEN, FL 34787 |
STE 170 WINTER GARDEN, FL 34787 |
CCC1331270 (Exp: 08/31/2026) | 407-649-1333 |
ANTONIO VINCENZO DAHM
| Status | Location Address | State License Number | Phone |
| ACTIVE |
10 RYBAR LANE PALM COAST, FL 32164 |
CFC1429951 (Exp: 08/31/2026) | 386-237-5692 |
Inspection History
| Type | Request Date | Result | Inspector |
| U-CROSS CONNECTION | 08/25/2023 | APPROVED - AS NOTED | LFITZGERALD |
| Note: no irrigation-no cross connectin | |||
| BLD - BUILDING FINAL | 08/22/2023 | FINAL APPROVED | KSANDOE |
| Note: 8/17/2023 - PREVIOUS INSPECTION NOTES 8/14/2023 - PREVIOUS INSPECTION NOTES Energy calcs have not been approved. Building Final inspection should should not be scheduled until all documents have been approved 8/11/2023 - PREVIOUS INSPECTION NOTES 8/11/23: Both Units: Energy Calcs still do not match for AHUs Unit B: Inspection now complete. 1). Water heater relief valve discharge pipe is too long per FBC P504.6. (1-1/2" minimum gap) 8/4/2023 - PREVIOUS INSPECTION NOTES 8/4/23: INSPECTION STOPPED! Please check both units for complete code compliance before calling back in for re-inspection. Unit A: Complete Inspection. 1). Missing supply register in Master Bedroom WIC highlighted on duct/register plan. 2). Energy Calcs do not match installed equipment. 3). Range anti-tip device is not anchored properly with 2 anchors into bottom plate or floor. One anchor is only into drywall. Also, hole in wall (Party wall) needs to be firestopped in approved manner. 4). Microwave exhaust is not sealed (firestopped) at the top in cabinet. Cannot verify if properly firestopped at drywall penetration. 5). Front door is missing door seals at the top and right jambs. 6). Hole in exterior wall at low voltage wires needs to be sealed. (Left side). 7). Front bathroom toilet seat is very loose. Unit B: Incomplete Inspection - Smokes & Bathrooms are the only items approved. 1). Energy Calcs do not match installed equipment. 2). Range anti-tip device not installed. 3). Dining Room outlet missing cover plate. 4). Kitchen counter has loose outlets - Need to check all. 5). Missing supply register in Master Bedroom WIC. 8/2/2023 - PREVIOUS INSPECTION NOTES Unit A. No working lights in hallway or front bedroom Multiple breakers tripped Stopped inspection. Please ensure property is ready for inspection 7/26/2023 - PREVIOUS INSPECTION NOTES House is locked. Need access for inspection FRC110.1 8-17-23 1. Firewall nailing needs to be approved before moving forward. | |||
| FIREWALL FINAL | 08/21/2023 | APPROVED | KSANDOE |
| BLD - BUILDING FINAL | 08/17/2023 | Disapproved - NO FEE | BTAYLOR |
| Note: 8/14/2023 - PREVIOUS INSPECTION NOTES Energy calcs have not been approved. Building Final inspection should should not be scheduled until all documents have been approved 8/11/2023 - PREVIOUS INSPECTION NOTES 8/11/23: Both Units: Energy Calcs still do not match for AHUs Unit B: Inspection now complete. 1). Water heater relief valve discharge pipe is too long per FBC P504.6. (1-1/2" minimum gap) 8/4/2023 - PREVIOUS INSPECTION NOTES 8/4/23: INSPECTION STOPPED! Please check both units for complete code compliance before calling back in for re-inspection. Unit A: Complete Inspection. 1). Missing supply register in Master Bedroom WIC highlighted on duct/register plan. 2). Energy Calcs do not match installed equipment. 3). Range anti-tip device is not anchored properly with 2 anchors into bottom plate or floor. One anchor is only into drywall. Also, hole in wall (Party wall) needs to be firestopped in approved manner. 4). Microwave exhaust is not sealed (firestopped) at the top in cabinet. Cannot verify if properly firestopped at drywall penetration. 5). Front door is missing door seals at the top and right jambs. 6). Hole in exterior wall at low voltage wires needs to be sealed. (Left side). 7). Front bathroom toilet seat is very loose. Unit B: Incomplete Inspection - Smokes & Bathrooms are the only items approved. 1). Energy Calcs do not match installed equipment. 2). Range anti-tip device not installed. 3). Dining Room outlet missing cover plate. 4). Kitchen counter has loose outlets - Need to check all. 5). Missing supply register in Master Bedroom WIC. 8/2/2023 - PREVIOUS INSPECTION NOTES Unit A. No working lights in hallway or front bedroom Multiple breakers tripped Stopped inspection. Please ensure property is ready for inspection 7/26/2023 - PREVIOUS INSPECTION NOTES House is locked. Need access for inspection FRC110.1 8-17-23 1. Firewall nailing needs to be approved before moving forward. | |||
| BLD - BUILDING FINAL | 08/14/2023 | Disapproved -FEE REQUIRED | KSANDOE |
| Note: Energy calcs have not been approved. Building Final inspection should should not be scheduled until all documents have been approved 8/11/2023 - PREVIOUS INSPECTION NOTES 8/11/23: Both Units: Energy Calcs still do not match for AHUs Unit B: Inspection now complete. 1). Water heater relief valve discharge pipe is too long per FBC P504.6. (1-1/2" minimum gap) 8/4/2023 - PREVIOUS INSPECTION NOTES 8/4/23: INSPECTION STOPPED! Please check both units for complete code compliance before calling back in for re-inspection. Unit A: Complete Inspection. 1). Missing supply register in Master Bedroom WIC highlighted on duct/register plan. 2). Energy Calcs do not match installed equipment. 3). Range anti-tip device is not anchored properly with 2 anchors into bottom plate or floor. One anchor is only into drywall. Also, hole in wall (Party wall) needs to be firestopped in approved manner. 4). Microwave exhaust is not sealed (firestopped) at the top in cabinet. Cannot verify if properly firestopped at drywall penetration. 5). Front door is missing door seals at the top and right jambs. 6). Hole in exterior wall at low voltage wires needs to be sealed. (Left side). 7). Front bathroom toilet seat is very loose. Unit B: Incomplete Inspection - Smokes & Bathrooms are the only items approved. 1). Energy Calcs do not match installed equipment. 2). Range anti-tip device not installed. 3). Dining Room outlet missing cover plate. 4). Kitchen counter has loose outlets - Need to check all. 5). Missing supply register in Master Bedroom WIC. 8/2/2023 - PREVIOUS INSPECTION NOTES Unit A. No working lights in hallway or front bedroom Multiple breakers tripped Stopped inspection. Please ensure property is ready for inspection 7/26/2023 - PREVIOUS INSPECTION NOTES House is locked. Need access for inspection FRC110.1 | |||
| BLD - BUILDING FINAL | 08/11/2023 | Disapproved - NO FEE | RSIMS |
| Note: 8/11/23: Both Units: Energy Calcs still do not match for AHUs Unit B: Inspection now complete. 1). Water heater relief valve discharge pipe is too long per FBC P504.6. (1-1/2" minimum gap) 8/4/2023 - PREVIOUS INSPECTION NOTES 8/4/23: INSPECTION STOPPED! Please check both units for complete code compliance before calling back in for re-inspection. Unit A: Complete Inspection. 1). Missing supply register in Master Bedroom WIC highlighted on duct/register plan. 2). Energy Calcs do not match installed equipment. 3). Range anti-tip device is not anchored properly with 2 anchors into bottom plate or floor. One anchor is only into drywall. Also, hole in wall (Party wall) needs to be firestopped in approved manner. 4). Microwave exhaust is not sealed (firestopped) at the top in cabinet. Cannot verify if properly firestopped at drywall penetration. 5). Front door is missing door seals at the top and right jambs. 6). Hole in exterior wall at low voltage wires needs to be sealed. (Left side). 7). Front bathroom toilet seat is very loose. Unit B: Incomplete Inspection - Smokes & Bathrooms are the only items approved. 1). Energy Calcs do not match installed equipment. 2). Range anti-tip device not installed. 3). Dining Room outlet missing cover plate. 4). Kitchen counter has loose outlets - Need to check all. 5). Missing supply register in Master Bedroom WIC. 8/2/2023 - PREVIOUS INSPECTION NOTES Unit A. No working lights in hallway or front bedroom Multiple breakers tripped Stopped inspection. Please ensure property is ready for inspection 7/26/2023 - PREVIOUS INSPECTION NOTES House is locked. Need access for inspection FRC110.1 | |||
| BLD - BUILDING FINAL | 08/04/2023 | Disapproved -FEE REQUIRED | RSIMS |
| Note: 8/4/23: INSPECTION STOPPED! Please check both units for complete code compliance before calling back in for re-inspection. Unit A: Complete Inspection. 1). Missing supply register in Master Bedroom WIC highlighted on duct/register plan. 2). Energy Calcs do not match installed equipment. 3). Range anti-tip device is not anchored properly with 2 anchors into bottom plate or floor. One anchor is only into drywall. Also, hole in wall (Party wall) needs to be firestopped in approved manner. 4). Microwave exhaust is not sealed (firestopped) at the top in cabinet. Cannot verify if properly firestopped at drywall penetration. 5). Front door is missing door seals at the top and right jambs. 6). Hole in exterior wall at low voltage wires needs to be sealed. (Left side). 7). Front bathroom toilet seat is very loose. Unit B: Incomplete Inspection - Smokes & Bathrooms are the only items approved. 1). Energy Calcs do not match installed equipment. 2). Range anti-tip device not installed. 3). Dining Room outlet missing cover plate. 4). Kitchen counter has loose outlets - Need to check all. 5). Missing supply register in Master Bedroom WIC. 8/2/2023 - PREVIOUS INSPECTION NOTES Unit A. No working lights in hallway or front bedroom Multiple breakers tripped Stopped inspection. Please ensure property is ready for inspection 7/26/2023 - PREVIOUS INSPECTION NOTES House is locked. Need access for inspection FRC110.1 | |||
| ROW - FINAL INSPECTION | 08/03/2023 | FINAL APPROVED | PFLANAGAN |
| Note: At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved. ----------------------------------------------------------------------------------- 7/26/2023 - PREVIOUS INSPECTION NOTES 07/26/23 CULVERT IS FULL OF DIRT AND SILT, WHOLE PIPE NEEDS TO BE CLEANED OUT. IT IS NOT ALLOWING WATER TO DRAIN TO CITY DITCH. 43 IS FULL OF DIRT AS WELL AND NEEDS TO BE FULLY CLEANED OUT TO ALLOW SWALE TO DRAIN TO DITCH. I AM NOT GOING TO FEE YOU TODAY. MAKE THE CORRECTION PLEASE. | |||
| U -UTILITY RESIDENTIAL FINAL | 08/03/2023 | FINAL APPROVED | DHANEY |
| Note: 7/26/2023 - PREVIOUS INSPECTION NOTES need sod around water mete boxes/2nd sewer clean out cap too high-need to be flush like 1st clean out is | |||
| BLD - BUILDING FINAL | 08/02/2023 | Disapproved -FEE REQUIRED | KSANDOE |
| Note: Unit A. No working lights in hallway or front bedroom Multiple breakers tripped Stopped inspection. Please ensure property is ready for inspection 7/26/2023 - PREVIOUS INSPECTION NOTES House is locked. Need access for inspection FRC110.1 | |||
| BLD - BUILDING FINAL | 07/26/2023 | Disapproved -FEE REQUIRED | KSANDOE |
| Note: House is locked. Need access for inspection FRC110.1 | |||
| ROW - FINAL INSPECTION | 07/26/2023 | Disapproved - NO FEE | FSLADISH |
| Note: 07/26/23 CULVERT IS FULL OF DIRT AND SILT, WHOLE PIPE NEEDS TO BE CLEANED OUT. IT IS NOT ALLOWING WATER TO DRAIN TO CITY DITCH. 43 IS FULL OF DIRT AS WELL AND NEEDS TO BE FULLY CLEANED OUT TO ALLOW SWALE TO DRAIN TO DITCH. I AM NOT GOING TO FEE YOU TODAY. MAKE THE CORRECTION PLEASE. | |||
| U -UTILITY RESIDENTIAL FINAL | 07/26/2023 | Disapproved -FEE REQUIRED | LFITZGERALD |
| Note: need sod around water mete boxes/2nd sewer clean out cap too high-need to be flush like 1st clean out is | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 07/24/2023 | APPROVED | PFLANAGAN |
| Note: At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved. ---------------------------------------------------------------------------------------- 7/13/2023 - PREVIOUS INSPECTION NOTES 07/13/23 you submitted the wrong survey. this survey is for 43 Ponce Deleon not 41 Ponce deleon. 7/11/2023 - PREVIOUS INSPECTION NOTES 07/11/23 NEED TO SHOW ELEVATIONS ON RIGHT SIDE PROPERTY LINE ON A 20' GRID. WHAT YOU ARE SHOWING WITH LIMITED ELEVATION SHOTS IS FLAT DRAINAGE FOR MORE THAN 20'. YOUR SITE PLANE PROPOSES INSIDE PROPERTY LINE DRAINAGE BETWEEN THE HOMES. THIS SHOULD BE A COMMON SWALE WITH ADJOINING PROPERTY. NEED 10' OFFSET SHOTS FROM ADJOINING PROPERTY. Elevations every 20 ft. on the property line Sec 300.01D1 Sec 300.01D1 The elevations along all property lines must be at a minimum of 20 foot intervals. Propose Drainage Pattern Section 300.01c(5) Section 300.01c(5).The proposed elevations shall be shown at all locations of existing elevations per the topographic survey. There must be sufficient elevation shots to indicate the proposed drainage pattern. Elevations every 20 ft off the property lines Sec 300.01D2 Sec 300.01 D2 The elevations on all adjacent identified (e.g. vacant or improved etc.) properties at a minimum of 20 foot intervals on a 10 foot offset outside the property lines. Rear Yard Drainage Sec 300.01(4,5,6) Sec 300.01(4,5,6) The tolerance along side lot lines is no more than 20 feet flat, with positive fall on each side.Positive fall is considered to be 0.10 feet in 20 feet.The minimum fall from the rear property line to the front is 0.50 feet. __________________________________________________________________________________________________________________________ 7/5/2023 - PREVIOUS INSPECTION NOTES 07/05/23 NEED TO SHOW POSITIVE DRAINAGE FROM REAR TO FRONT OF PROPERTY NEED TO LIST ALL FFE FOR ADJACENT PROPERTIES. NEED TO SHOW ALL CULVERT ELEVATIONS WITHIN 130 FT OF LOT LINE. Lot must drain. Section 300.01 (A)(1)(C)(6) Section 300.01 (A)(1)(C)(6). Unless specifically stated the subject lot must drain from back to front or a portion may be drained to an adjacent City drainage feature. (B) ________________________________________________________________________________________________________________________ 6/22/2023 - PREVIOUS INSPECTION NOTES 1) Sec 300.01 D2 The elevations on all adjacent identified (e.g. vacant or improved etc.) properties at a minimum of 20 foot intervals on a 10 foot offset outside the property lines. All undeveloped properties must be properly identified on the site plan and Final Survey. There must be sufficient elevation shots to indicate the intended drainage pattern. 2) Sec 300.01 D3 The interior elevations at no greater than a 20 foot grid. There must be sufficient elevation shots to indicate the intended drainage pattern. Don't have sufficient elevation to determind if road side swale flows in right direction. | |||
| ROW FIELD SURVEY /GRADING CERTIFICATION | 07/24/2023 | APPROVED | PFLANAGAN |
| Note: At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved. | |||
| ROW - FINAL APRON (AFTER POUR) | 07/24/2023 | APPROVED | PFLANAGAN |
| Note: At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved. | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 07/13/2023 | Disapproved - NO FEE | FSLADISH |
| Note: 07/13/23 you submitted the wrong survey. this survey is for 43 Ponce Deleon not 41 Ponce deleon. 7/11/2023 - PREVIOUS INSPECTION NOTES 07/11/23 NEED TO SHOW ELEVATIONS ON RIGHT SIDE PROPERTY LINE ON A 20' GRID. WHAT YOU ARE SHOWING WITH LIMITED ELEVATION SHOTS IS FLAT DRAINAGE FOR MORE THAN 20'. YOUR SITE PLANE PROPOSES INSIDE PROPERTY LINE DRAINAGE BETWEEN THE HOMES. THIS SHOULD BE A COMMON SWALE WITH ADJOINING PROPERTY. NEED 10' OFFSET SHOTS FROM ADJOINING PROPERTY. Elevations every 20 ft. on the property line Sec 300.01D1 Sec 300.01D1 The elevations along all property lines must be at a minimum of 20 foot intervals. Propose Drainage Pattern Section 300.01c(5) Section 300.01c(5).The proposed elevations shall be shown at all locations of existing elevations per the topographic survey. There must be sufficient elevation shots to indicate the proposed drainage pattern. Elevations every 20 ft off the property lines Sec 300.01D2 Sec 300.01 D2 The elevations on all adjacent identified (e.g. vacant or improved etc.) properties at a minimum of 20 foot intervals on a 10 foot offset outside the property lines. Rear Yard Drainage Sec 300.01(4,5,6) Sec 300.01(4,5,6) The tolerance along side lot lines is no more than 20 feet flat, with positive fall on each side.Positive fall is considered to be 0.10 feet in 20 feet.The minimum fall from the rear property line to the front is 0.50 feet. __________________________________________________________________________________________________________________________ 7/5/2023 - PREVIOUS INSPECTION NOTES 07/05/23 NEED TO SHOW POSITIVE DRAINAGE FROM REAR TO FRONT OF PROPERTY NEED TO LIST ALL FFE FOR ADJACENT PROPERTIES. NEED TO SHOW ALL CULVERT ELEVATIONS WITHIN 130 FT OF LOT LINE. Lot must drain. Section 300.01 (A)(1)(C)(6) Section 300.01 (A)(1)(C)(6). Unless specifically stated the subject lot must drain from back to front or a portion may be drained to an adjacent City drainage feature. (B) ________________________________________________________________________________________________________________________ 6/22/2023 - PREVIOUS INSPECTION NOTES 1) Sec 300.01 D2 The elevations on all adjacent identified (e.g. vacant or improved etc.) properties at a minimum of 20 foot intervals on a 10 foot offset outside the property lines. All undeveloped properties must be properly identified on the site plan and Final Survey. There must be sufficient elevation shots to indicate the intended drainage pattern. 2) Sec 300.01 D3 The interior elevations at no greater than a 20 foot grid. There must be sufficient elevation shots to indicate the intended drainage pattern. Don't have sufficient elevation to determind if road side swale flows in right direction. | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 07/11/2023 | Disapproved - NO FEE | FSLADISH |
| Note: 07/11/23 NEED TO SHOW ELEVATIONS ON RIGHT SIDE PROPERTY LINE ON A 20' GRID. WHAT YOU ARE SHOWING WITH LIMITED ELEVATION SHOTS IS FLAT DRAINAGE FOR MORE THAN 20'. YOUR SITE PLANE PROPOSES INSIDE PROPERTY LINE DRAINAGE BETWEEN THE HOMES. THIS SHOULD BE A COMMON SWALE WITH ADJOINING PROPERTY. NEED 10' OFFSET SHOTS FROM ADJOINING PROPERTY. Elevations every 20 ft. on the property line Sec 300.01D1 Sec 300.01D1 The elevations along all property lines must be at a minimum of 20 foot intervals. Propose Drainage Pattern Section 300.01c(5) Section 300.01c(5).The proposed elevations shall be shown at all locations of existing elevations per the topographic survey. There must be sufficient elevation shots to indicate the proposed drainage pattern. Elevations every 20 ft off the property lines Sec 300.01D2 Sec 300.01 D2 The elevations on all adjacent identified (e.g. vacant or improved etc.) properties at a minimum of 20 foot intervals on a 10 foot offset outside the property lines. Rear Yard Drainage Sec 300.01(4,5,6) Sec 300.01(4,5,6) The tolerance along side lot lines is no more than 20 feet flat, with positive fall on each side.Positive fall is considered to be 0.10 feet in 20 feet.The minimum fall from the rear property line to the front is 0.50 feet. __________________________________________________________________________________________________________________________ 7/5/2023 - PREVIOUS INSPECTION NOTES 07/05/23 NEED TO SHOW POSITIVE DRAINAGE FROM REAR TO FRONT OF PROPERTY NEED TO LIST ALL FFE FOR ADJACENT PROPERTIES. NEED TO SHOW ALL CULVERT ELEVATIONS WITHIN 130 FT OF LOT LINE. Lot must drain. Section 300.01 (A)(1)(C)(6) Section 300.01 (A)(1)(C)(6). Unless specifically stated the subject lot must drain from back to front or a portion may be drained to an adjacent City drainage feature. (B) ________________________________________________________________________________________________________________________ 6/22/2023 - PREVIOUS INSPECTION NOTES 1) Sec 300.01 D2 The elevations on all adjacent identified (e.g. vacant or improved etc.) properties at a minimum of 20 foot intervals on a 10 foot offset outside the property lines. All undeveloped properties must be properly identified on the site plan and Final Survey. There must be sufficient elevation shots to indicate the intended drainage pattern. 2) Sec 300.01 D3 The interior elevations at no greater than a 20 foot grid. There must be sufficient elevation shots to indicate the intended drainage pattern. Don't have sufficient elevation to determind if road side swale flows in right direction. | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 07/05/2023 | Disapproved - NO FEE | FSLADISH |
| Note: 07/05/23 NEED TO SHOW POSITIVE DRAINAGE FROM REAR TO FRONT OF PROPERTY NEED TO LIST ALL FFE FOR ADJACENT PROPERTIES. NEED TO SHOW ALL CULVERT ELEVATIONS WITHIN 130 FT OF LOT LINE. Lot must drain. Section 300.01 (A)(1)(C)(6) Section 300.01 (A)(1)(C)(6). Unless specifically stated the subject lot must drain from back to front or a portion may be drained to an adjacent City drainage feature. (B) ________________________________________________________________________________________________________________________ 6/22/2023 - PREVIOUS INSPECTION NOTES 1) Sec 300.01 D2 The elevations on all adjacent identified (e.g. vacant or improved etc.) properties at a minimum of 20 foot intervals on a 10 foot offset outside the property lines. All undeveloped properties must be properly identified on the site plan and Final Survey. There must be sufficient elevation shots to indicate the intended drainage pattern. 2) Sec 300.01 D3 The interior elevations at no greater than a 20 foot grid. There must be sufficient elevation shots to indicate the intended drainage pattern. Don't have sufficient elevation to determind if road side swale flows in right direction. | |||
| ELECTRIC - EARLY POWER | 06/26/2023 | APPROVED - AS NOTED | KSANDOE |
| Note: Emailed FPL @ 1314. Release Power 6/20/2023 - PREVIOUS INSPECTION NOTES Protection for ground. Ground wire needs to be protected Disconnect for AC cannot be behind unit Inspector Notes from Inspection 2170 Emailed FPL @ 1247. Release Power | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 06/22/2023 | Disapproved - NO FEE | PFLANAGAN |
| Note: 1) Sec 300.01 D2 The elevations on all adjacent identified (e.g. vacant or improved etc.) properties at a minimum of 20 foot intervals on a 10 foot offset outside the property lines. All undeveloped properties must be properly identified on the site plan and Final Survey. There must be sufficient elevation shots to indicate the intended drainage pattern. 2) Sec 300.01 D3 The interior elevations at no greater than a 20 foot grid. There must be sufficient elevation shots to indicate the intended drainage pattern. Don't have sufficient elevation to determind if road side swale flows in right direction. | |||
| ELECTRIC - EARLY POWER | 06/20/2023 | Disapproved - NO FEE | KSANDOE |
| Note: Protection for ground. Ground wire needs to be protected Disconnect for AC cannot be behind unit Inspector Notes from Inspection 2170 Emailed FPL @ 1247. Release Power | |||
| ROW- PRE-APRON (PRE-POUR) | 05/22/2023 | Disapproved - NO FEE | GBERTOLA |
| Note: 5/22/23= idon't know why this is approved inspector wasn't there. I DID ADD AGAIN ANOTHER PRE POUR INSPECTION 5/18/2023 - PREVIOUS INSPECTION NOTES 5/18/23= NEED TO HAVE POSITIVE FLOW TO THE FRONT. FROM BOTH SIDE OF THE APRON TO THE DRIVEWAY WATER IS GOING BACKWARD. CULVERT PIPE IS GOOD +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 5/17/2023 - PREVIOUS INSPECTION NOTES CANCELLED BY CM DO TO FROMS ARE NOT COMPLETED -------------------------------------------------------------------------- 5/16/2023 - PREVIOUS INSPECTION NOTES NOT READY | |||
| ROW- PRE-APRON (PRE-POUR) | 05/22/2023 | APPROVED - AS NOTED | GBERTOLA |
| Note: 5/22/2023= CORRECTION WERE MADE AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS BEFORE POURING. MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 5/22/23= idon't know why this is approved inspector wasn't there. I DID ADD AGAIN ANOTHER PRE POUR INSPECTION 5/18/2023 - PREVIOUS INSPECTION NOTES 5/18/23= NEED TO HAVE POSITIVE FLOW TO THE FRONT. FROM BOTH SIDE OF THE APRON TO THE DRIVEWAY WATER IS GOING BACKWARD. CULVERT PIPE IS GOOD +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 5/17/2023 - PREVIOUS INSPECTION NOTES CANCELLED BY CM DO TO FROMS ARE NOT COMPLETED -------------------------------------------------------------------------- 5/16/2023 - PREVIOUS INSPECTION NOTES NOT READY | |||
| ROW- PRE-APRON (PRE-POUR) | 05/18/2023 | Disapproved - NO FEE | GBERTOLA |
| Note: 5/18/23= NEED TO HAVE POSITIVE FLOW TO THE FRONT. FROM BOTH SIDE OF THE APRON TO THE DRIVEWAY WATER IS GOING BACKWARD. CULVERT PIPE IS GOOD +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 5/17/2023 - PREVIOUS INSPECTION NOTES CANCELLED BY CM DO TO FROMS ARE NOT COMPLETED -------------------------------------------------------------------------- 5/16/2023 - PREVIOUS INSPECTION NOTES NOT READY | |||
| ROW- PRE-APRON (PRE-POUR) | 05/17/2023 | CANCELLED BY APPLICANT | PFLANAGAN |
| Note: CANCELLED BY CM DO TO FROMS ARE NOT COMPLETED -------------------------------------------------------------------------- 5/16/2023 - PREVIOUS INSPECTION NOTES NOT READY | |||
| ROW- PRE-APRON (PRE-POUR) | 05/16/2023 | CANCELLED BY APPLICANT | PFLANAGAN |
| Note: NOT READY | |||
| U - SEWER TIE IN | 05/09/2023 | APPROVED | MGIBSON |
| Note: 5/5/2023 - PREVIOUS INSPECTION NOTES Unable to view connections. Trench flooded 5/4/2023 - PREVIOUS INSPECTION NOTES Trenches flooded. Plumbing not holding water. Unable to see connections | |||
| GRAVITY SEWER TEST | 05/08/2023 | Disapproved - NO FEE | KSANDOE |
| Note: Still not holding water. 5/5/2023 - PREVIOUS INSPECTION NOTES Not holding water. Test failed New inspection due to canceled inspection New inspection due to canceled inspection 5/4/2023 - PREVIOUS INSPECTION NOTES Trenches flooded. Plumbing not holding water. Unable to see connections | |||
| GRAVITY SEWER TEST | 05/08/2023 | APPROVED | KSANDOE |
| Note: 5/8/2023 - PREVIOUS INSPECTION NOTES Still not holding water. 5/5/2023 - PREVIOUS INSPECTION NOTES Not holding water. Test failed New inspection due to canceled inspection New inspection due to canceled inspection 5/4/2023 - PREVIOUS INSPECTION NOTES Trenches flooded. Plumbing not holding water. Unable to see connections | |||
| GRAVITY SEWER TEST | 05/05/2023 | CANCELLED BY APPLICANT | WEB |
| Note: 5/4/2023 - PREVIOUS INSPECTION NOTES Trenches flooded. Plumbing not holding water. Unable to see connections | |||
| GRAVITY SEWER TEST | 05/05/2023 | CANCELLED BY APPLICANT | WEB |
| Note: New inspection due to canceled inspection 5/4/2023 - PREVIOUS INSPECTION NOTES Trenches flooded. Plumbing not holding water. Unable to see connections | |||
| GRAVITY SEWER TEST | 05/05/2023 | Disapproved -FEE REQUIRED | KSANDOE |
| Note: Not holding water. Test failed New inspection due to canceled inspection New inspection due to canceled inspection 5/4/2023 - PREVIOUS INSPECTION NOTES Trenches flooded. Plumbing not holding water. Unable to see connections | |||
| U - SEWER TIE IN | 05/05/2023 | Disapproved - NO FEE | KSANDOE |
| Note: Unable to view connections. Trench flooded 5/4/2023 - PREVIOUS INSPECTION NOTES Trenches flooded. Plumbing not holding water. Unable to see connections | |||
| U - SEWER TIE IN | 05/04/2023 | Disapproved - NO FEE | KSANDOE |
| Note: Trenches flooded. Plumbing not holding water. Unable to see connections | |||
| GRAVITY SEWER TEST | 05/04/2023 | Disapproved - NO FEE | KSANDOE |
| Note: Trenches flooded. Plumbing not holding water. Unable to see connections | |||
| PEP TANK INSTALLATION REQUEST | 04/19/2023 | APPROVED | TSCHWEERS |
| INSULATION | 04/10/2023 | APPROVED | KSANDOE |
| Note: Inspector Notes from Inspection 2420 Overhead service wire needs to be sunlight resistant Will check front doors at insulation inspection | |||
| ELECTRIC TEMP POLE | 04/10/2023 | APPROVED - AS NOTED | KSANDOE |
| Note: Emailed FPL @ 1247. Release Power | |||
| ALL ROUGH | 03/31/2023 | APPROVED - AS NOTED | KSANDOE |
| Note: Overhead service wire needs to be sunlight resistant Will check front doors at insulation inspection | |||
| LATH/BRICK/ WATER BARRIER | 03/30/2023 | APPROVED | KSANDOE |
| FIREWALL DRYWALL NAILING | 03/22/2023 | CANCELLED BY INSPECTOR | KSANDOE |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 03/21/2023 | APPROVED | KSANDOE |
| Note: 3/15/2023 - PREVIOUS INSPECTION NOTES 3/9/2023 - PREVIOUS INSPECTION NOTES Still missing requested details Framing crews working, job incomplete Still missing anchors 3/7/2023 - PREVIOUS INSPECTION NOTES Roof was walked sheating fastening passes inspection. Approved to cover roof. Fire rated plywood is in place. Down cells pass inspection. 1. Please have a truss drawing and engineering packet onsite for inspection. 2. The bearing walls in both units have not been built as per detials, missing anchors. 3. Please provide a detail on how the bottom plate of the firewall is to be attached to the CMU wall. Inspection was stopped due to missing drawing and multiple missing anchors. A full inspection still needed. | |||
| ROOF VALLEY & METAL | 03/15/2023 | APPROVED | KSANDOE |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 03/15/2023 | CANCELLED BY APPLICANT | KSANDOE |
| Note: 3/9/2023 - PREVIOUS INSPECTION NOTES Still missing requested details Framing crews working, job incomplete Still missing anchors 3/7/2023 - PREVIOUS INSPECTION NOTES Roof was walked sheating fastening passes inspection. Approved to cover roof. Fire rated plywood is in place. Down cells pass inspection. 1. Please have a truss drawing and engineering packet onsite for inspection. 2. The bearing walls in both units have not been built as per detials, missing anchors. 3. Please provide a detail on how the bottom plate of the firewall is to be attached to the CMU wall. Inspection was stopped due to missing drawing and multiple missing anchors. A full inspection still needed. | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 03/09/2023 | Disapproved -FEE REQUIRED | KSANDOE |
| Note: Still missing requested details Framing crews working, job incomplete Still missing anchors 3/7/2023 - PREVIOUS INSPECTION NOTES Roof was walked sheating fastening passes inspection. Approved to cover roof. Fire rated plywood is in place. Down cells pass inspection. 1. Please have a truss drawing and engineering packet onsite for inspection. 2. The bearing walls in both units have not been built as per detials, missing anchors. 3. Please provide a detail on how the bottom plate of the firewall is to be attached to the CMU wall. Inspection was stopped due to missing drawing and multiple missing anchors. A full inspection still needed. | |||
| WALL SHEATHING | 03/07/2023 | APPROVED | JWALKER |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 03/07/2023 | Disapproved - NO FEE | JWALKER |
| Note: Roof was walked sheating fastening passes inspection. Approved to cover roof. Fire rated plywood is in place. Down cells pass inspection. 1. Please have a truss drawing and engineering packet onsite for inspection. 2. The bearing walls in both units have not been built as per detials, missing anchors. 3. Please provide a detail on how the bottom plate of the firewall is to be attached to the CMU wall. Inspection was stopped due to missing drawing and multiple missing anchors. A full inspection still needed. | |||
| TIE BEAM / LINTEL | 02/28/2023 | APPROVED | KSANDOE |
| FOUND SURVEY APPROVED (OFFICE) | 02/23/2023 | APPROVED | TBAKER |
| WATER METER INSTALLATION REQUEST | 02/16/2023 | APPROVED | TSCHWEERS |
| MONOLITHIC SLAB | 02/14/2023 | APPROVED | KSANDOE |
| PLUMBING 1ST ROUGH UNDERGROUND | 02/10/2023 | CANCELLED BY INSPECTOR | LMUSGROVE |
| Note: NOC needs to be corrected and re-recorded | |||
| PLUMBING 1ST ROUGH UNDERGROUND | 02/10/2023 | APPROVED | TSTAUFFACHER |
Review History
| Department | Status | Date In | Date Out |
| MECH | COMPLETE | 08/15/2023 | 08/16/2023 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| MECH | HOLD | 08/14/2023 | 08/15/2023 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Energy Calcs need to be signed by the owner/ owner agent below the preparer per R103.1.1.2 FBC Energy Conservation 2020 7Th edition | |||
| MECH | COMPLETE | 07/10/2023 | 07/10/2023 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| MECH | HOLD | 06/30/2023 | 07/06/2023 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM 1. Energy Calcs need to be signed by the owner/ owner agent below the preparer per R103.1.1.2 FBC Energy Conservation 2020 7Th edition 2. Provide adjacent wall insulation and type on Energy calcs. 3. TMY site on Energy calcs needs to be Daytona Beach | |||
| BLD | COMPLETE | 03/20/2023 | 03/20/2023 |
| Note: Released By: PATRICK BUCKLEY - (386)986-3786 - PBUCKLEY@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 03/20/2023 | 03/20/2023 |
| Note: Released By: PATRICK BUCKLEY - (386)986-3786 - PBUCKLEY@PALMCOASTGOV.COM | |||
| BLD | HOLD | 03/14/2023 | 03/15/2023 |
| Note: Held By: PATRICK BUCKLEY - (386)986-3786 - PBUCKLEY@PALMCOASTGOV.COM Submitted detail does not match actual conditions. Detail shows shaft liner firewall from foundation through a two story home to roof deck of roofs of different height. Actual conditions indicate a one story home with a CMU wall to the ceiling height. Firewall detail would only need to be from top of CMU wall to underside of roof sheathing. Inspector has indicated something entirely different is being constructed in the field. Detail needs to match actual construction. | |||
| BLD | HOLD | 03/09/2023 | 03/09/2023 |
| Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Plans submitted need to be digitally signed and sealed. | |||
| ENGIN1 | COMPLETE | 02/23/2023 | 02/23/2023 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 02/23/2023 | 02/23/2023 |
| Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 02/15/2023 | 02/22/2023 |
| Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM | |||
| BADMIN | INFORMATION | 02/08/2023 | 02/08/2023 |
| Note: Marked INFORMATION By: BARBIE BEMBRY - (386)986-3780 - BUILDINGDIVISION@PALMCOASTGOV.COM Rename file to notice of commencement. | |||
| BADMIN | COMPLETE | 02/08/2023 | 02/08/2023 |
| Note: Released By: SCOTT THOMAS - - STHOMAS@PALMCOASTGOV.COM NOC MISSING YEAR AT BOTTOM BY NOTARY. MUST BE RE-RECORDED WITH DIFFERENT INSTRUMENT # (2023004991) TO REFLECT OFFICIAL RECORDING WITH FLAGLER COUNTY CLERK OF COURT RECORDS | |||
| BLD | COMPLETE | 02/01/2023 | 02/07/2023 |
| Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM | |||
| ELEC | COMPLETE | 02/01/2023 | 02/01/2023 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 01/31/2023 | 01/31/2023 |
| Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 01/25/2023 | 01/25/2023 |
| Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM EXTERIOR STONE REMOVED | |||
| MECH | COMPLETE | 01/25/2023 | 01/26/2023 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| SWALE | COMPLETE | 01/18/2023 | 04/20/2023 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 01/17/2023 | 01/18/2023 |
| Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM | |||
| MECH | HOLD | 01/17/2023 | 01/17/2023 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM 1. Provide details wall insulation. Energy Calcs show block with R13. 3/4 inch foam board is R5 typically. Show insulation on plans. 2. Provide Energy calcs for both sides of duplex | |||
| BLD | COMPLETE | 01/17/2023 | 01/18/2023 |
| Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 01/17/2023 | 01/25/2023 |
| Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 01/17/2023 | 01/17/2023 |
| Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 01/17/2023 | 01/18/2023 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| ELEC | COMPLETE | 01/17/2023 | 01/18/2023 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| MECH | HOLD | 01/12/2023 | 01/12/2023 |
| Note: Held By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM All comments below per the 2020 Florida Building Code REVIEW COMMENTS: 1. Chosen equipment on heatload exceeds the maximum of 1.15 times the load calculated per R403.7.1.2.1 FBC Energy Conservation 2020 7TH Edition 2. Direction house faces on Energy Calcs does not match the site plan. Revise to match per R405.4.2.1 FBC Energy Conservation 2020 7Th Edition 3. Duct layout needs to show duct sizing per manual D and returns in all areas 4. Duct layout needs to be signed by the AC contractor per 107.1 FBC Residential 2020 7th Edition 5. Design location and TMY site on Energy Calcs needs to be Daytona Beach 6. Design location on heatload needs to be Daytona Beach. 7. Square footage on energy calcs does not match the House plans 8. Provide Heatload for both sides of duplex 9. Proposed windows are aluminum. Energy Forms show vinyl windows to be installed. A revision to the proposed approval or energy forms is required to reference the correct windows to be installed. | |||
| BLD | HOLD | 01/06/2023 | 01/12/2023 |
| Note: Held By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM All comments below per the 2020 Florida Building Code REVIEW COMMENTS: 1. Details A5 and A6 on Sheet SD.2 reference a fire rated wall. Provide details and UL listing for proposed fire rated wall. | |||
| CUSVC | COMPLETE | 01/06/2023 | 01/06/2023 |
| Note: Released By: HALEIGH HAND - - | |||
| ELEC | HOLD | 01/06/2023 | 01/06/2023 |
| Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM Submit electric load calcs | |||
| ENGIN1 | HOLD | 01/06/2023 | 01/06/2023 |
| Note: Held By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM Survey elevations need to be carried out to the nearest hundredth of a foot. | |||
| LOCATE | COMPLETE | 01/06/2023 | 01/10/2023 |
| Note: Released By: CANDACE STONE - - CSTONE@PALMCOASTGOV.COM | |||
| MECH | HOLD | 01/06/2023 | 01/09/2023 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM 1. Chosen equipment on heatload exceeds the maximum of 1.15 times the load calculated.per R403.7.1.2.1 FBC Energy Conservation 2020 7TH Edition 2. Direction house faces on Energy Calcs does not match the site plan. Revise to match per R405.4.2.1 FBC Energy Conservation 2020 7Th Edition 3. Duct layout needs to show duct sizing per manual D and returns in all areas 4. Duct layout needs to be signed by the AC contractor per 107.1 FBC Residential 2020 7th Edition 5. Design location and TMY site on Energy Calcs needs to be Daytona Beach 6. Design location on heatload needs to be Daytona Beach. 7. Square footage on energy calcs does not match the House plans 8. Provide Heatload for both sides of duplex | |||
| SW1 | HOLD | 01/06/2023 | 01/13/2023 |
| Note: Held By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM NEED TO HAVE PROPOSED ELEVATIONS ON ALL FOUR CORNERS OF THE HOUSE SO WE CAN DETERMINE IF YOU HAVE 4" BELOW FFE | |||
| ZON | HOLD | 01/06/2023 | 01/06/2023 |
| Note: Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM Please provide total driveway width at the widest point. Cannot exceed 40ft total landscape plan missing from submittal |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| PLAN REVIEW - REVISION | ¤32.50 | 08/23/2023 |
| PLAN REVIEW - REVISION | ¤32.50 | 08/23/2023 |
| PLAN REVIEW - REVISION | ¤65.00 | 08/23/2023 |
| PLAN REVIEW - REVISION | ¤32.50 | 08/23/2023 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 08/23/2023 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 08/23/2023 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 08/23/2023 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 08/23/2023 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 08/23/2023 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 08/23/2023 |
| CONTRACTOR CHANGE | ¤20.00 | 08/23/2023 |
| REINSPECTION FEE | ¤40.00 | 08/23/2023 |
| SURCHARGE FS 533.721 | ¤3.49 | 01/31/2023 |
| SURCHARGE - FS 468.631 | ¤5.24 | 01/31/2023 |
| SW ENG - FOUNDATION SURVEY | ¤20.00 | 01/31/2023 |
| SW ENG INSPECTION 80 | ¤80.00 | 01/31/2023 |
| SW ENG PRE APRON | ¤30.00 | 01/31/2023 |
| SW ENG - REVIEW 20 | ¤20.00 | 01/31/2023 |
| SW ENG RES REVIEW 200 | ¤200.00 | 01/31/2023 |
| TRANS IMPACT FEE ADMIN | ¤84.36 | 01/31/2023 |
| TRANS IMPACT FEE ADMIN | (¤84.36) | 01/31/2023 |
| SEWER CREDIT | (¤1,300.00) | 01/31/2023 |
| SEWER INSPECTION | ¤25.00 | 01/31/2023 |
| SEWER CAPITAL FACILITY | ¤10,689.64 | 01/31/2023 |
| WATER CAPITAL FACILITY FEE | ¤7,847.76 | 01/31/2023 |
| SITE PLAN 30 | ¤30.00 | 01/31/2023 |
| WATER- TURN ON | ¤50.00 | 01/31/2023 |
| ADJUSTMENT 50% | (¤544.50) | 01/31/2023 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 01/31/2023 |
| INSPECTION - RESIDENTIAL | ¤825.00 | 01/31/2023 |
| PLAN REVIEW - RESIDENTIAL | ¤234.00 | 01/31/2023 |
| FIRE IMPACT FEE ADMIN | ¤25.23 | 01/31/2023 |
| FIRE IMPACT FEE ADMIN | (¤25.23) | 01/31/2023 |
| FC IMPACT FEE EMS | ¤124.00 | 01/31/2023 |
| IMPACT FEE FIRE | ¤841.04 | 01/31/2023 |
| FC IMPACT FEE LAW ENFORCEMENT | ¤436.00 | 01/31/2023 |
| FC IMPACT FEE LIBRARY | ¤536.00 | 01/31/2023 |
| IMPACT FEE PARKS | ¤3,538.30 | 01/31/2023 |
| IMPACT FEE SCHOOL | ¤10,900.00 | 01/31/2023 |
| IMPACT FEE TRANSPORTATION | ¤2,812.00 | 01/31/2023 |
| WATER -IRRIGATION INSPECTION | ¤50.00 | 01/31/2023 |
| PARKS IMPACT FEE ADMIN | ¤106.15 | 01/31/2023 |
| PARKS IMPACT FEE ADMIN | (¤106.15) | 01/31/2023 |
| CONNECTION FEES | ¤2,332.52 | 01/31/2023 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤40,277.99 |