I want to search for...
Permit #2023010402
Permit Details
Status: COED
| Parcel Id: 07-11-31-7064-00390-0010 |
| CONDITIONED SPACE: 1831 sqft |
| GARAGE: 473 sqft |
| OPENED PORCH (WITH ROOF) : 116 sqft |
| OPENED PORCH (WITH ROOF) : 245 sqft |
| OPENED PORCH (WITH ROOF) : 85 sqft |
| Total Square Footage: 2750 sqft |
| Block: 00390 |
| Subdivision: - |
| Job Phone: 386-237-1210 |
| Location Address: 42 LLEWELLYN TR |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 07/19/2023 |
| NOC: RECORDED |
| Applicant name: ANDREW POPOV |
| Owner: SILVER BREEZE LLC |
|
Address 1 SEATHORN PATH UNIT A PALM COAST, FL 32164 |
| Lot: 0010 |
| Contracted Stated Job Value: ¤250,000.00 |
| Job Description: Single Family Residence |
| Type: CN |
Contractor
SILVER BREEZE HOMES
| Status | Location Address | State License Number | Phone |
| ACTIVE |
1 SEATHORN PATH UNIT A PALM COAST, FL 32164 |
RR282812121 (Exp: 08/31/2027) | 386-237-7700 |
Sub Contractors
GARY LLOYD SHEFFIELD
| Status | Location Address | State License Number | Phone |
| ACTIVE |
48 EAGLE LAKES DRIVE FLAGLER BEACH, FL 32136 |
CAC048127 (Exp: 08/31/2026) | 386-597-3280 |
HEATH EDWARD SANFORD
| Status | Location Address | State License Number | Phone |
| ACTIVE |
126 EAST END RD SAN MATEO, FL 32187 |
CFC1429896 (Exp: 08/31/2026) | 386-871-8823 |
MAXIM BUDNIK
| Status | Location Address | State License Number | Phone |
| ACTIVE |
9788 HALSEY RD JACKSONVILLE, FL 32246 |
EC13007415 (Exp: 08/31/2026) | 904-509-7306 |
OLEG BELINSKIY
| Status | Location Address | State License Number | Phone |
| ACTIVE |
19 PINE CIRCLE DRIVE19 PALM COAST, FL 32167 |
CCC1325974 (Exp: 08/31/2026) | 386-263-7906 |
Inspection History
| Type | Request Date | Result | Inspector |
| BLD - BUILDING FINAL | 07/15/2025 | FINAL APPROVED | KSANDOE |
| U-CROSS CONNECTION | 05/16/2025 | APPROVED | BWRIGHT |
| U -UTILITY RESIDENTIAL FINAL | 05/16/2025 | FINAL APPROVED | BWRIGHT |
| ROW - STORMWATER FINAL | 05/14/2025 | APPROVED | FSLADISH |
| Note: 5/14/25 AT THE TIME OF THIS INSPECTION ALL MINIMUM COPC REQUIEMENT ARE MET. BUILDER TO BE HELD RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. THIS INCLUDES BUT IS NOT LIMITED TO THE CULVERT PIPE ELEVATION APPROVAL FOR THE CONCRETE POUR. | |||
| ROW - FINAL APRON (AFTER POUR) | 05/14/2025 | APPROVED | FSLADISH |
| Note: 5/14/25 PIPE ELEVATION IS GOOD, CUTS ARE MADE, CULVERT CLEAR, HOT PATCH COMPLETE. AT THE TIME OF THE INSPECTION ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 05/08/2025 | APPROVED | FSLADISH |
| ROW FIELD SURVEY /GRADING CERTIFICATION | 05/08/2025 | APPROVED | FSLADISH |
| Note: 5/8/25 UPON WALKING PROPERTY DRAINAGE WILL WORK AS INDICATED ON FINAL SURVEY. AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. _________________________________________________________________________________________________________________________ NOTE TO INSPECTOR BUILDER WANTS TO PUT ROCK BED ON LEFT SIDE OF POOL OUT LIKE 10' THEN SOD REST. ANY QUESTION CALL PARREN OR TALK WITH BUILDER. | |||
| ROW- PROJECT STATUS | 04/17/2025 | Status Check | PFLANAGAN |
| Note: MEETING WITH BUILDER ABOUT GRADING AND WHERE HE NEEDS TO PUT SOD BEHIND FENCE. | |||
| ROW- PRE-APRON (PRE-POUR) | 02/27/2025 | APPROVED | FSLADISH |
| Note: 2/27/25 PIPE ELEVATIONS GOOD. BUILDER TO USE MINIMUM 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. AT THE TIME OF THE INSPECTION READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK ELEVATIONS MAKE SURE CONCRETE IS 3000 PSI BUILDER RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. THIS INCLUDES BUT IS NOT LIMITED TO THE CULVERT PIPE ELEVATION APPROVAL FOR THE CONCRETE POUR. | |||
| WINDOW NAILING | 12/09/2024 | APPROVED | BTAYLOR |
| Note: Inspector Notes from Inspection 2490 Please leave trim off front entry and dwelling/garage door for inspection 10/30/2024 - PREVIOUS INSPECTION NOTES 10/30/2024 1. Previous notes not addressed. House needs to be sealed for insulation. Inspector Notes from Inspection 2420 10/21/2024 1. Front and House to Garage doors not installed. Check at insulation. | |||
| ELECTRIC - EARLY POWER | 12/02/2024 | APPROVED | PKNAPIK |
| Note: Release Power Inspector Notes from Inspection 2200 *** NOTES ADDED BY RMARTIN 9/24/2024 1:02:34 PM *** did this inspection on 9/23/24 9/24/2024 - PREVIOUS INSPECTION NOTES *** NOTES ADDED BY RMARTIN 9/24/2024 9:19:17 AM *** Need to have sch 80 pvc for underground nec 300.5, also need to glue connections when sch 80 is installed | |||
| GRAVITY SEWER TEST | 11/07/2024 | APPROVED - AS NOTED | MGIBSON |
| Note: THIS WAS A VIRTUAL INSPECTION | |||
| U - SEWER TIE IN | 11/07/2024 | APPROVED - AS NOTED | MGIBSON |
| Note: THIS WAS A VIRTUAL INSPECTION | |||
| INSULATION | 11/04/2024 | APPROVED - AS NOTED | KSANDOE |
| Note: Please leave trim off front entry and dwelling/garage door for inspection 10/30/2024 - PREVIOUS INSPECTION NOTES 10/30/2024 1. Previous notes not addressed. House needs to be sealed for insulation. Inspector Notes from Inspection 2420 10/21/2024 1. Front and House to Garage doors not installed. Check at insulation. | |||
| INSULATION | 10/30/2024 | Disapproved - NO FEE | PKNAPIK |
| Note: 10/30/2024 1. Previous notes not addressed. House needs to be sealed for insulation. Inspector Notes from Inspection 2420 10/21/2024 1. Front and House to Garage doors not installed. Check at insulation. | |||
| PEP TANK INSTALLATION REQUEST | 10/23/2024 | APPROVED | CBOWERMASTER |
| ALL ROUGH | 10/21/2024 | APPROVED - AS NOTED | PKNAPIK |
| Note: 10/21/2024 1. Front and House to Garage doors not installed. Check at insulation. | |||
| LATH/BRICK/ WATER BARRIER | 10/15/2024 | APPROVED | PKNAPIK |
| ELECTRIC-TUG | 09/25/2024 | APPROVED - AS NOTED | RMARTIN |
| Note: *** NOTES ADDED BY RMARTIN 9/24/2024 1:02:34 PM *** did this inspection on 9/23/24 9/24/2024 - PREVIOUS INSPECTION NOTES *** NOTES ADDED BY RMARTIN 9/24/2024 9:19:17 AM *** Need to have sch 80 pvc for underground nec 300.5, also need to glue connections when sch 80 is installed | |||
| ELECTRIC-TUG | 09/24/2024 | Disapproved - NO FEE | RMARTIN |
| Note: *** NOTES ADDED BY RMARTIN 9/24/2024 9:19:17 AM *** Need to have sch 80 pvc for underground nec 300.5, also need to glue connections when sch 80 is installed | |||
| ROOF VALLEY & METAL | 09/24/2024 | APPROVED | BTAYLOR |
| ELECTRIC-TUG | 09/23/2024 | CANCELLED BY APPLICANT | WEB |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 09/19/2024 | APPROVED | KSANDOE |
| Note: 9/17/2024 - PREVIOUS INSPECTION NOTES 9/17/24: No Change 9/6/2024 - PREVIOUS INSPECTION NOTES Garage dwelling seperation wall must have support bearing more than existing. FBC2304.3.1 | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 09/17/2024 | Disapproved - NO FEE | RSIMS |
| Note: 9/17/24: No Change 9/6/2024 - PREVIOUS INSPECTION NOTES Garage dwelling seperation wall must have support bearing more than existing. FBC2304.3.1 | |||
| WALL SHEATHING | 09/06/2024 | APPROVED | KSANDOE |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 09/06/2024 | Disapproved - NO FEE | KSANDOE |
| Note: *** NOTES ADDED BY KSANDOE 9/6/2024 10:42:48 AM *** Ok to dry in roof Garage dwelling seperation wall must have support bearing more than existing. FBC2304.3.1 | |||
| TIE BEAM / LINTEL | 08/16/2024 | APPROVED | KSANDOE |
| FOUND SURVEY APPROVED (OFFICE) | 03/04/2024 | APPROVED | TBAKER |
| MONOLITHIC SLAB | 02/21/2024 | Disapproved -FEE REQUIRED | RSIMS |
| Note: 2/21/24: 1). Garage entry footer still does not match plan details. Needs to be 16" deep per the scale listed on the plan. Please run a string line equal with the finished garage floor height at this footer and leave in place for the re-inspection. 2/20/2024 - PREVIOUS INSPECTION NOTES 2/20/24: Please fix chairs that have come out of place & add any chairs needed to maintain wire mesh clearance. 1). Footers at the garage and at front do not match plan details. Highlighted. | |||
| MONOLITHIC SLAB | 02/21/2024 | APPROVED | KSANDOE |
| Note: 2/21/2024 - PREVIOUS INSPECTION NOTES 2/21/24: 1). Garage entry footer still does not match plan details. Needs to be 16" deep per the scale listed on the plan. Please run a string line equal with the finished garage floor height at this footer and leave in place for the re-inspection. 2/20/2024 - PREVIOUS INSPECTION NOTES 2/20/24: Please fix chairs that have come out of place & add any chairs needed to maintain wire mesh clearance. 1). Footers at the garage and at front do not match plan details. Highlighted. | |||
| MONOLITHIC SLAB | 02/20/2024 | Disapproved - NO FEE | RSIMS |
| Note: 2/20/24: Please fix chairs that have come out of place & add any chairs needed to maintain wire mesh clearance. 1). Footers at the garage and at front do not match plan details. Highlighted. | |||
| PLUMBING 1ST ROUGH UNDERGROUND | 01/19/2024 | APPROVED | MGIBSON |
| WATER METER INSTALLATION REQUEST | 08/08/2023 | APPROVED | CBOWERMASTER |
Review History
| Department | Status | Date In | Date Out |
| BLD | COMPLETE | 10/01/2024 | 10/01/2024 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| BLD | HOLD | 09/25/2024 | 09/30/2024 |
| Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Highlight changed number or only submit number tht is changing. | |||
| BLD | COMPLETE | 09/18/2024 | 09/23/2024 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 09/11/2024 | 09/16/2024 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 07/15/2024 | 07/15/2024 |
| Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 07/15/2024 | 07/15/2024 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 07/15/2024 | 07/22/2024 |
| Note: Released By: JOHN HOWARD - - JHOWARD@PALMCOASTGOV.COM SW1 completed review is contingent on stormwater inspector's approval of the final survey. A failed final survey inspection and/or a revised site plan indicating any significant change in drainage patterns and elevations negatively impacting neighboring lots, or the structure will result in a HOLD | |||
| ZON | HOLD | 07/08/2024 | 07/08/2024 |
| Note: Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM Please show driveway width at the widest point of the 2 car garage It cannot exceed 36ft before you start the circular. Please show a minimum 5ft setback from the arc to the front property line | |||
| ENGIN1 | COMPLETE | 03/04/2024 | 03/04/2024 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 03/04/2024 | 03/04/2024 |
| Note: Released By: MICHELLE RAMOS - (386)986-3780 - MRAMOS@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 10/02/2023 | 10/02/2023 |
| Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 10/02/2023 | 10/03/2023 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 10/02/2023 | 10/03/2023 |
| Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM | |||
| LOCATE | COMPLETE | 10/02/2023 | 10/04/2023 |
| Note: Released By: CANDACE BOWERMASTER - - CBOWERMASTER@PALMCOASTGOV.COM | |||
| ZON | HOLD | 09/21/2023 | 09/21/2023 |
| Note: Held By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM Please revise site plan - the closest point of the front of the home must meet the minimum 25' required front setback. | |||
| SWALE | COMPLETE | 01/12/2023 | 04/21/2023 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 01/09/2023 | 01/13/2023 |
| Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM | |||
| CUSVC | COMPLETE | 01/09/2023 | 01/12/2023 |
| Note: Released By: LISA ASBILL - - lasbill@palmcoastgov.com | |||
| ELEC | COMPLETE | 01/09/2023 | 01/10/2023 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 01/09/2023 | 01/12/2023 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| LOCATE | COMPLETE | 01/09/2023 | 01/12/2023 |
| Note: Released By: CANDACE STONE - - CSTONE@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 01/09/2023 | 01/10/2023 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 01/09/2023 | 01/18/2023 |
| Note: Released By: EDWARD MADISON - - EMADISON@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 01/09/2023 | 01/10/2023 |
| Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| IMPACT FEE TRANSPORTATION | ¤1,812.00 | 06/30/2025 |
| IMPACT FEE FIRE | ¤420.52 | 06/30/2025 |
| IMPACT FEE PARKS | ¤1,769.15 | 06/30/2025 |
| IMPACT FEE SCHOOL | ¤5,450.00 | 07/19/2023 |
| FC IMPACT FEE LAW ENFORCEMENT | ¤218.00 | 07/19/2023 |
| FC IMPACT FEE LIBRARY | ¤268.00 | 07/19/2023 |
| WATER- TURN ON | ¤25.00 | 07/19/2023 |
| ADJUSTMENT 50% | (¤456.25) | 07/19/2023 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 07/19/2023 |
| INSPECTION - RESIDENTIAL | ¤687.50 | 07/19/2023 |
| PLAN REVIEW - RESIDENTIAL | ¤195.00 | 07/19/2023 |
| CONNECTION FEES | ¤1,166.26 | 07/19/2023 |
| FIRE IMPACT FEE ADMIN | ¤12.62 | 07/19/2023 |
| FIRE IMPACT FEE ADMIN | (¤12.62) | 07/19/2023 |
| FC IMPACT FEE EMS | ¤62.00 | 07/19/2023 |
| WATER -IRRIGATION INSPECTION | ¤25.00 | 07/19/2023 |
| PARKS IMPACT FEE ADMIN | ¤53.07 | 07/19/2023 |
| PARKS IMPACT FEE ADMIN | (¤53.07) | 07/19/2023 |
| SURCHARGE FS 533.721 | ¤2.99 | 07/19/2023 |
| SURCHARGE - FS 468.631 | ¤4.48 | 07/19/2023 |
| SW ENG - FOUNDATION SURVEY | ¤20.00 | 07/19/2023 |
| SW ENG INSPECTION 80 | ¤80.00 | 07/19/2023 |
| SW ENG PRE APRON | ¤30.00 | 07/19/2023 |
| SW ENG - REVIEW 20 | ¤20.00 | 07/19/2023 |
| SW ENG RES REVIEW 200 | ¤200.00 | 07/19/2023 |
| TRANS IMPACT FEE ADMIN | ¤54.36 | 07/19/2023 |
| TRANS IMPACT FEE ADMIN | (¤54.36) | 07/19/2023 |
| SEWER CREDIT | (¤850.00) | 07/19/2023 |
| SEWER INSPECTION | ¤25.00 | 07/19/2023 |
| SEWER CAPITAL FACILITY | ¤5,344.82 | 07/19/2023 |
| WATER CAPITAL FACILITY FEE | ¤3,923.88 | 07/19/2023 |
| SITE PLAN 30 | ¤30.00 | 07/19/2023 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤20,503.35 |