Permit #2023010646
Permit Details
Status: COED
| Parcel Id: 07-11-31-7028-00140-0230 |
| CONDITIONED SPACE: 1298 sqft |
| GARAGE: 262 sqft |
| OPENED PORCH (WITH ROOF) : 27 sqft |
| OPENED PORCH (WITH ROOF) : 50 sqft |
| CONDITIONED SPACE: 1298 sqft |
| GARAGE: 262 sqft |
| OPENED PORCH (WITH ROOF) : 50 sqft |
| OPENED PORCH (WITH ROOF) : 27 sqft |
| Total Square Footage: 3274 sqft |
| Block: 00140 |
| Subdivision: 2199 - SECTION 28-WYNNFIELD |
| Job Phone: 863-647-5815 |
| Location Address: 43 PONCE DELEON DR |
| Type: DU - DUPLEX |
| Issue Date: 02/02/2023 |
| NOC: RECORDED |
| Applicant name: MARK ALLAN HULBERT |
| Owner: HULBERT HOMES INC |
|
Address PO BOX 6254 LAKELAND , FL 33807 |
| Lot: 0230 |
| Contracted Stated Job Value: ¤300,000.00 |
| Job Description: Duplex |
| Type: CN |
Contractor
HULBERT HOMES INC
| Status | Location Address | State License Number | Phone |
| INACTIVE |
PO BOX 6254 LAKELAND, FL 33813 |
CRC1331304 (Exp: 08/31/2026) | 863-647-5815 |
Sub Contractors
MOISES MERINO DIAZ
| Status | Location Address | State License Number | Phone |
| ACTIVE |
3104 ORANOLE ROAD ORLANDO, FL 32810 |
CAC1820980 (Exp: 08/31/2026) | 407-225-3149 |
JASON ERIC ARMSTRONG
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
3624 DMG DRIVE LAKELAND, FL 33811 |
CCC1332575 (Exp: 08/31/2026) | 863-201-6025 | 863-583-0408 |
JOHN EDWARD GAMBONE
| Status | Location Address | Mailing Address | State License Number | Phone |
| ACTIVE |
15 HARGROVE LN PALM COAST, FL 32137 |
1G PALM COAST, FL 32137 |
EC13006037 (Exp: 08/31/2026) | 386-586-9144 |
ANTONIO VINCENZO DAHM
| Status | Location Address | State License Number | Phone |
| ACTIVE |
10 RYBAR LANE PALM COAST, FL 32164 |
CFC1429951 (Exp: 08/31/2026) | 386-237-5692 |
Inspection History
| Type | Request Date | Result | Inspector |
| U-CROSS CONNECTION | 09/28/2023 | APPROVED - AS NOTED | LFITZGERALD |
| Note: Inspector Notes from Inspection 9500 ? both units have PVB for irrigtion but only unitA has irrigation meter-just a fyi that unit A will be paying a monthly service for that meter if not needed since they are irrigating off the potable line | |||
| ROW - FINAL INSPECTION | 09/27/2023 | APPROVED | PFLANAGAN |
| Note: At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved. --------------------------------------------------------------------------- 9/26/2023 - PREVIOUS INSPECTION NOTES NEED TO CLEAN OUT ALL DIRT OUT OF THE CULVERT PIPE ------------------------------------------------------------------------------ 9/22/2023 - PREVIOUS INSPECTION NOTES 9/19/2023 - PREVIOUS INSPECTION NOTES 09/19/23 THERE IS A LOW AREA ON THE LEFT SIDE TOWARDS THE REAR OUTLINED IN WHITE PAINT THAT IS LOW AND HOLDING WATER.. THIS IS ALSO INDICATED ON THE SURVEY AS FLAT AND THEN GIONG 1 TENTH UPHILL. THIS NEEDS TO FLOW FROM THE REAR FORWARD. NEEDS TO BE CORRECTED. CULVERT ENDS NEED TO BE CLEANED OUT. NOT GOING TO FEE YOU TODAY AS I WAS ALREADY HERE FOR THE AFTERPOUR INSPECTION. PLEASE MAKE CORRECTIONS BEFORE RESUBMITTING FOR ROW FINAL. | |||
| ROW - FINAL INSPECTION | 09/26/2023 | Disapproved -FEE REQUIRED | PFLANAGAN |
| Note: NEED TO CLEAN OUT ALL DIRT OUT OF THE CULVERT PIPE ------------------------------------------------------------------------------ 9/22/2023 - PREVIOUS INSPECTION NOTES 9/19/2023 - PREVIOUS INSPECTION NOTES 09/19/23 THERE IS A LOW AREA ON THE LEFT SIDE TOWARDS THE REAR OUTLINED IN WHITE PAINT THAT IS LOW AND HOLDING WATER.. THIS IS ALSO INDICATED ON THE SURVEY AS FLAT AND THEN GIONG 1 TENTH UPHILL. THIS NEEDS TO FLOW FROM THE REAR FORWARD. NEEDS TO BE CORRECTED. CULVERT ENDS NEED TO BE CLEANED OUT. NOT GOING TO FEE YOU TODAY AS I WAS ALREADY HERE FOR THE AFTERPOUR INSPECTION. PLEASE MAKE CORRECTIONS BEFORE RESUBMITTING FOR ROW FINAL. | |||
| ROW - FINAL INSPECTION | 09/22/2023 | CANCELLED BY APPLICANT | FSLADISH |
| Note: 9/19/2023 - PREVIOUS INSPECTION NOTES 09/19/23 THERE IS A LOW AREA ON THE LEFT SIDE TOWARDS THE REAR OUTLINED IN WHITE PAINT THAT IS LOW AND HOLDING WATER.. THIS IS ALSO INDICATED ON THE SURVEY AS FLAT AND THEN GIONG 1 TENTH UPHILL. THIS NEEDS TO FLOW FROM THE REAR FORWARD. NEEDS TO BE CORRECTED. CULVERT ENDS NEED TO BE CLEANED OUT. NOT GOING TO FEE YOU TODAY AS I WAS ALREADY HERE FOR THE AFTERPOUR INSPECTION. PLEASE MAKE CORRECTIONS BEFORE RESUBMITTING FOR ROW FINAL. | |||
| ROW FIELD SURVEY /GRADING CERTIFICATION | 09/19/2023 | APPROVED | PFLANAGAN |
| Note: At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved. --------------------------------------------------------------------------------- 7/10/2023 - PREVIOUS INSPECTION NOTES 7/10/23= BOTH SIDES NEED TO SHOW POSITEVE FALL RIGHT SIDE AND LEFT SIDE YOU NEED TO SUBMIT A NEW SURVEY SHOING POSITIVE FALL TO THE FRONT. The tolerance alongside lot lines is no more than 20 feet flat, with positive fall on each side. Positive fall is considered to be 0.10 feet in 20 feet. The minimum fall from the rear property line to the front is 0.50 feet. Sec 300.01 (A)(1)(C)(6). Unless specifically stated the subject lot must drain from back to front or a portion may be drained to an adjacent City drainage feature. (B) | |||
| ROW - FINAL INSPECTION | 09/19/2023 | Disapproved - NO FEE | FSLADISH |
| Note: 09/19/23 THERE IS A LOW AREA ON THE LEFT SIDE TOWARDS THE REAR OUTLINED IN WHITE PAINT THAT IS LOW AND HOLDING WATER.. THIS IS ALSO INDICATED ON THE SURVEY AS FLAT AND THEN GIONG 1 TENTH UPHILL. THIS NEEDS TO FLOW FROM THE REAR FORWARD. NEEDS TO BE CORRECTED. CULVERT ENDS NEED TO BE CLEANED OUT. NOT GOING TO FEE YOU TODAY AS I WAS ALREADY HERE FOR THE AFTERPOUR INSPECTION. PLEASE MAKE CORRECTIONS BEFORE RESUBMITTING FOR ROW FINAL. | |||
| U -UTILITY RESIDENTIAL FINAL | 09/19/2023 | APPROVED - AS NOTED | LFITZGERALD |
| Note: ? both units have PVB for irrigtion but only unitA has irrigation meter-just a fyi that unit A will be paying a monthly service for that meter if not needed since they are irrigating off the potable line | |||
| ROW - FINAL APRON (AFTER POUR) | 09/19/2023 | APPROVED | FSLADISH |
| Note: 09/19/23 PIPE IS GOOD. CUTS MADE. HOT PATCH COMPLETED. At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved. | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 09/18/2023 | APPROVED | PFLANAGAN |
| Note: At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved. ------------------------------------------------------------------------------- 9/1/2023 - PREVIOUS INSPECTION NOTES 9/1/23= No changes in the final survey 1) Sod elevations adjacent to the structure are 4” below the FFE for block and 6” for wood frame structures. (D)D.Florida Building Code, Residential, Chapter 4, R404.1.6 2) Drainage from the structure is to be a 6 inch (5%) minimum slope for the first 10’.(E) E.Florida Building Code, Residential, Chapter 4,R401.3B.Land Development Code Technical Manual, Section 300.01 (A)(1)(C)(6). Please check final survey for the remarks on red. 8/22/2023 - PREVIOUS INSPECTION NOTES 8/22/23= 1) Sod elevations adjacent to the structure are 4” below the FFE for block and 6” for wood frame structures. (D)D.Florida Building Code, Residential, Chapter 4, R404.1.6 2) Drainage from the structure is to be a 6 inch (5%) minimum slope for the first 10’.(E) E.Florida Building Code, Residential, Chapter 4,R401.3B.Land Development Code Technical Manual, Section 300.01 (A)(1)(C)(6). Please check final survey for the remarks on red. ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 3) The subject lots drainage must not negatively impact any adjacent property. (B) 8/18/2023 - PREVIOUS INSPECTION NOTES 08/18/23 THERE ARE NO ELEVATION SHOTS ACROSS FRONT PROPERTY LINE, ELEVATIONS MUST BE SHOT AT 20' INTERVALS. THERE ARE NO ELEVATION SHOTS IN THE SWALE TO DETERMINE IF DRAINAGE WILL WORK. THERE ARE NO ELEVATION SHOTS ON THE RIGHT SIDE PROPERTY LINES OR 10' OFFSETS ON RIGHT SIDE AS REQUIRED. I NEED ELEVATION ON THE BACK PATIO .Drainage from the structure is to be a 6 inch (5%) minimum slope for the first 10’.(E).The tolerance along side lot lines is no more than 20 feet flat, with positive fall on each side. Positive fall is considered to be 0.10 feet in 20 feet.Sec 300.01D2 Sec 300.01 D2 The elevations on all adjacent identified (e.g. vacant or improved etc.) properties at a minimum of 20 foot intervals on a 10 foot offset outside the property lines. All undeveloped properties must be properly identified on the site plan and Final Survey. There must be sufficient elevation shots to indicate the intended drainage pattern. 7/26/2023 - PREVIOUS INSPECTION NOTES 7/26/23= ELEVATIONS ON THE BACK YEAR RUNNING FLAT.The tolerance along side lot lines is no more than 20 feet flat, with positive fall on each side. Positive fall is considered to be 0.10 feet in 20 feet. The minimum fall from the rear property line to the front IS 0.50 feet. I NEED ELEVATIONS ON THE FRONT PROPERTY LINEI NEED ELEVATION ON THE BACK PATIO .Drainage from the structure is to be a 6 inch (5%) minimum slope for the first 10’.(E) I NEED ELEVATION ON THE BACK PATIO .Drainage from the structure is to be a 6 inch (5%) minimum slope for the first 10’.(E) LEFT SIDE SWALE IS TOO HIGH STOPING THE FLOW OF THE WATER MATCH EXISTING GRADE 7/10/2023 - PREVIOUS INSPECTION NOTES 7/10/23= BOTH SIDES NEED TO SHOW POSITEVE FALL RIGHT SIDE AND LEFT SIDE YOU NEED TO SUBMIT A NEW SURVEY SHOING POSITIVE FALL TO THE FRONT. The tolerance alongside lot lines is no more than 20 feet flat, with positive fall on each side. Positive fall is considered to be 0.10 feet in 20 feet. The minimum fall from the rear property line to the front is 0.50 feet. Sec 300.01 (A)(1)(C)(6). Unless specifically stated the subject lot must drain from back to front or a portion may be drained to an adjacent City drainage feature. (B) 7/5/2023 - PREVIOUS INSPECTION NOTES 07/05/23 NEED TO SHOW POSITIVE DRAINAGE FROM REAR TO FRONT OF PROPERTY NEED TO LIST ALL FFE FOR ADJACENT PROPERTIES. NEED TO SHOW ALL CULVERT ELEVATIONS WITHIN 130 FT OF LOT LINE. _________________________________________________________________________________________________________________________ 6/26/2023 - PREVIOUS INSPECTION NOTES 06/26/23 NEED TO PROVIDE ELEVATION SHOTS ON THE LEFT SIDE INSIDE PROPERTY LINE IN 20' INTERVALS SO WE CAN DETERMINE IF THERE IS POSITIVE DRAINAGE FROM REAR TO FRONT WITHOUT ANY ADVERSE DRAINAGE TO ADJACENT PROPERTY OWNER. SITE PLAN INDICATES INSIDE DRAINAGE, WE DO NOT HAVE ANY SHOTS TO DETERMINE DRAINAGE FLOW. Inspector Notes from Inspection 9270 5/22/23=CORRECTION WERE MADE AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS BEFORE POURING. MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 5/18/2023 - PREVIOUS INSPECTION NOTES 5/18/23 MITER END ON THE RIGHT SIDE NEED TO BE AT 8 FT FROM THE ROAD EDGE NEED TO CHECK THE ELEVATION AGAIN. +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 5/17/2023 - PREVIOUS INSPECTION NOTES CANCELLED BY CM DO TO NOT FORMED ALL THE WAY -------------------------------------------------------------------------- 5/16/2023 - PREVIOUS INSPECTION NOTES NOT READY | |||
| BLD - BUILDING FINAL | 09/12/2023 | FINAL APPROVED | KSANDOE |
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 09/01/2023 | Disapproved -FEE REQUIRED | GBERTOLA |
| Note: 9/1/23= No changes in the final survey 1) Sod elevations adjacent to the structure are 4” below the FFE for block and 6” for wood frame structures. (D)D.Florida Building Code, Residential, Chapter 4, R404.1.6 2) Drainage from the structure is to be a 6 inch (5%) minimum slope for the first 10’.(E) E.Florida Building Code, Residential, Chapter 4,R401.3B.Land Development Code Technical Manual, Section 300.01 (A)(1)(C)(6). Please check final survey for the remarks on red. 8/22/2023 - PREVIOUS INSPECTION NOTES 8/22/23= 1) Sod elevations adjacent to the structure are 4” below the FFE for block and 6” for wood frame structures. (D)D.Florida Building Code, Residential, Chapter 4, R404.1.6 2) Drainage from the structure is to be a 6 inch (5%) minimum slope for the first 10’.(E) E.Florida Building Code, Residential, Chapter 4,R401.3B.Land Development Code Technical Manual, Section 300.01 (A)(1)(C)(6). Please check final survey for the remarks on red. ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 3) The subject lots drainage must not negatively impact any adjacent property. (B) 8/18/2023 - PREVIOUS INSPECTION NOTES 08/18/23 THERE ARE NO ELEVATION SHOTS ACROSS FRONT PROPERTY LINE, ELEVATIONS MUST BE SHOT AT 20' INTERVALS. THERE ARE NO ELEVATION SHOTS IN THE SWALE TO DETERMINE IF DRAINAGE WILL WORK. THERE ARE NO ELEVATION SHOTS ON THE RIGHT SIDE PROPERTY LINES OR 10' OFFSETS ON RIGHT SIDE AS REQUIRED. I NEED ELEVATION ON THE BACK PATIO .Drainage from the structure is to be a 6 inch (5%) minimum slope for the first 10’.(E).The tolerance along side lot lines is no more than 20 feet flat, with positive fall on each side. Positive fall is considered to be 0.10 feet in 20 feet.Sec 300.01D2 Sec 300.01 D2 The elevations on all adjacent identified (e.g. vacant or improved etc.) properties at a minimum of 20 foot intervals on a 10 foot offset outside the property lines. All undeveloped properties must be properly identified on the site plan and Final Survey. There must be sufficient elevation shots to indicate the intended drainage pattern. 7/26/2023 - PREVIOUS INSPECTION NOTES 7/26/23= ELEVATIONS ON THE BACK YEAR RUNNING FLAT.The tolerance along side lot lines is no more than 20 feet flat, with positive fall on each side. Positive fall is considered to be 0.10 feet in 20 feet. The minimum fall from the rear property line to the front IS 0.50 feet. I NEED ELEVATIONS ON THE FRONT PROPERTY LINEI NEED ELEVATION ON THE BACK PATIO .Drainage from the structure is to be a 6 inch (5%) minimum slope for the first 10’.(E) I NEED ELEVATION ON THE BACK PATIO .Drainage from the structure is to be a 6 inch (5%) minimum slope for the first 10’.(E) LEFT SIDE SWALE IS TOO HIGH STOPING THE FLOW OF THE WATER MATCH EXISTING GRADE 7/10/2023 - PREVIOUS INSPECTION NOTES 7/10/23= BOTH SIDES NEED TO SHOW POSITEVE FALL RIGHT SIDE AND LEFT SIDE YOU NEED TO SUBMIT A NEW SURVEY SHOING POSITIVE FALL TO THE FRONT. The tolerance alongside lot lines is no more than 20 feet flat, with positive fall on each side. Positive fall is considered to be 0.10 feet in 20 feet. The minimum fall from the rear property line to the front is 0.50 feet. Sec 300.01 (A)(1)(C)(6). Unless specifically stated the subject lot must drain from back to front or a portion may be drained to an adjacent City drainage feature. (B) 7/5/2023 - PREVIOUS INSPECTION NOTES 07/05/23 NEED TO SHOW POSITIVE DRAINAGE FROM REAR TO FRONT OF PROPERTY NEED TO LIST ALL FFE FOR ADJACENT PROPERTIES. NEED TO SHOW ALL CULVERT ELEVATIONS WITHIN 130 FT OF LOT LINE. _________________________________________________________________________________________________________________________ 6/26/2023 - PREVIOUS INSPECTION NOTES 06/26/23 NEED TO PROVIDE ELEVATION SHOTS ON THE LEFT SIDE INSIDE PROPERTY LINE IN 20' INTERVALS SO WE CAN DETERMINE IF THERE IS POSITIVE DRAINAGE FROM REAR TO FRONT WITHOUT ANY ADVERSE DRAINAGE TO ADJACENT PROPERTY OWNER. SITE PLAN INDICATES INSIDE DRAINAGE, WE DO NOT HAVE ANY SHOTS TO DETERMINE DRAINAGE FLOW. Inspector Notes from Inspection 9270 5/22/23=CORRECTION WERE MADE AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS BEFORE POURING. MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 5/18/2023 - PREVIOUS INSPECTION NOTES 5/18/23 MITER END ON THE RIGHT SIDE NEED TO BE AT 8 FT FROM THE ROAD EDGE NEED TO CHECK THE ELEVATION AGAIN. +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 5/17/2023 - PREVIOUS INSPECTION NOTES CANCELLED BY CM DO TO NOT FORMED ALL THE WAY -------------------------------------------------------------------------- 5/16/2023 - PREVIOUS INSPECTION NOTES NOT READY | |||
| ROW- PROJECT STATUS | 08/28/2023 | APPROVED | GBERTOLA |
| Note: THE SWALE ON THE RIGHT IS HIGHER THAN THE RUN ON THE LEFT, CAUSING WATER TO STOP FLOWING. THE FRONT SWALE MUST BE REGRADED AND LOWERED BY THE BUILDER IMMEDIATELY TO ENSURE UNIMPEDED WATER FLOW INTO THE SPILLWAY. PRESENT AT THE MEETING WERE INSPECTOR P. FLANAGAN AND G. BERTOL.A, CM DAVID | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 08/22/2023 | Disapproved - NO FEE | GBERTOLA |
| Note: 8/22/23= 1) Sod elevations adjacent to the structure are 4” below the FFE for block and 6” for wood frame structures. (D)D.Florida Building Code, Residential, Chapter 4, R404.1.6 2) Drainage from the structure is to be a 6 inch (5%) minimum slope for the first 10’.(E) E.Florida Building Code, Residential, Chapter 4,R401.3B.Land Development Code Technical Manual, Section 300.01 (A)(1)(C)(6). Please check final survey for the remarks on red. ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 3) The subject lots drainage must not negatively impact any adjacent property. (B) 8/18/2023 - PREVIOUS INSPECTION NOTES 08/18/23 THERE ARE NO ELEVATION SHOTS ACROSS FRONT PROPERTY LINE, ELEVATIONS MUST BE SHOT AT 20' INTERVALS. THERE ARE NO ELEVATION SHOTS IN THE SWALE TO DETERMINE IF DRAINAGE WILL WORK. THERE ARE NO ELEVATION SHOTS ON THE RIGHT SIDE PROPERTY LINES OR 10' OFFSETS ON RIGHT SIDE AS REQUIRED. I NEED ELEVATION ON THE BACK PATIO .Drainage from the structure is to be a 6 inch (5%) minimum slope for the first 10’.(E).The tolerance along side lot lines is no more than 20 feet flat, with positive fall on each side. Positive fall is considered to be 0.10 feet in 20 feet.Sec 300.01D2 Sec 300.01 D2 The elevations on all adjacent identified (e.g. vacant or improved etc.) properties at a minimum of 20 foot intervals on a 10 foot offset outside the property lines. All undeveloped properties must be properly identified on the site plan and Final Survey. There must be sufficient elevation shots to indicate the intended drainage pattern. 7/26/2023 - PREVIOUS INSPECTION NOTES 7/26/23= ELEVATIONS ON THE BACK YEAR RUNNING FLAT.The tolerance along side lot lines is no more than 20 feet flat, with positive fall on each side. Positive fall is considered to be 0.10 feet in 20 feet. The minimum fall from the rear property line to the front IS 0.50 feet. I NEED ELEVATIONS ON THE FRONT PROPERTY LINEI NEED ELEVATION ON THE BACK PATIO .Drainage from the structure is to be a 6 inch (5%) minimum slope for the first 10’.(E) I NEED ELEVATION ON THE BACK PATIO .Drainage from the structure is to be a 6 inch (5%) minimum slope for the first 10’.(E) LEFT SIDE SWALE IS TOO HIGH STOPING THE FLOW OF THE WATER MATCH EXISTING GRADE 7/10/2023 - PREVIOUS INSPECTION NOTES 7/10/23= BOTH SIDES NEED TO SHOW POSITEVE FALL RIGHT SIDE AND LEFT SIDE YOU NEED TO SUBMIT A NEW SURVEY SHOING POSITIVE FALL TO THE FRONT. The tolerance alongside lot lines is no more than 20 feet flat, with positive fall on each side. Positive fall is considered to be 0.10 feet in 20 feet. The minimum fall from the rear property line to the front is 0.50 feet. Sec 300.01 (A)(1)(C)(6). Unless specifically stated the subject lot must drain from back to front or a portion may be drained to an adjacent City drainage feature. (B) 7/5/2023 - PREVIOUS INSPECTION NOTES 07/05/23 NEED TO SHOW POSITIVE DRAINAGE FROM REAR TO FRONT OF PROPERTY NEED TO LIST ALL FFE FOR ADJACENT PROPERTIES. NEED TO SHOW ALL CULVERT ELEVATIONS WITHIN 130 FT OF LOT LINE. _________________________________________________________________________________________________________________________ 6/26/2023 - PREVIOUS INSPECTION NOTES 06/26/23 NEED TO PROVIDE ELEVATION SHOTS ON THE LEFT SIDE INSIDE PROPERTY LINE IN 20' INTERVALS SO WE CAN DETERMINE IF THERE IS POSITIVE DRAINAGE FROM REAR TO FRONT WITHOUT ANY ADVERSE DRAINAGE TO ADJACENT PROPERTY OWNER. SITE PLAN INDICATES INSIDE DRAINAGE, WE DO NOT HAVE ANY SHOTS TO DETERMINE DRAINAGE FLOW. Inspector Notes from Inspection 9270 5/22/23=CORRECTION WERE MADE AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS BEFORE POURING. MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 5/18/2023 - PREVIOUS INSPECTION NOTES 5/18/23 MITER END ON THE RIGHT SIDE NEED TO BE AT 8 FT FROM THE ROAD EDGE NEED TO CHECK THE ELEVATION AGAIN. +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 5/17/2023 - PREVIOUS INSPECTION NOTES CANCELLED BY CM DO TO NOT FORMED ALL THE WAY -------------------------------------------------------------------------- 5/16/2023 - PREVIOUS INSPECTION NOTES NOT READY | |||
| FIREWALL FINAL | 08/21/2023 | APPROVED | KSANDOE |
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 08/18/2023 | Disapproved -FEE REQUIRED | FSLADISH |
| Note: 08/18/23 THERE ARE NO ELEVATION SHOTS ACROSS FRONT PROPERTY LINE, ELEVATIONS MUST BE SHOT AT 20' INTERVALS. THERE ARE NO ELEVATION SHOTS IN THE SWALE TO DETERMINE IF DRAINAGE WILL WORK. THERE ARE NO ELEVATION SHOTS ON THE RIGHT SIDE PROPERTY LINES OR 10' OFFSETS ON RIGHT SIDE AS REQUIRED. I NEED ELEVATION ON THE BACK PATIO .Drainage from the structure is to be a 6 inch (5%) minimum slope for the first 10’.(E).The tolerance along side lot lines is no more than 20 feet flat, with positive fall on each side. Positive fall is considered to be 0.10 feet in 20 feet.Sec 300.01D2 Sec 300.01 D2 The elevations on all adjacent identified (e.g. vacant or improved etc.) properties at a minimum of 20 foot intervals on a 10 foot offset outside the property lines. All undeveloped properties must be properly identified on the site plan and Final Survey. There must be sufficient elevation shots to indicate the intended drainage pattern. Section 300.01 Section 300.01.Identify how the rear yard will be drained. The rear yard is required to drain to the front yard swale, unless the Topographic Survey/Lot Grading Plan demonstrates a rear yard drainage system with an appropriate outfall. Flooding or draining onto adjacent properties will not be allowed 7/26/2023 - PREVIOUS INSPECTION NOTES 7/26/23= ELEVATIONS ON THE BACK YEAR RUNNING FLAT.The tolerance along side lot lines is no more than 20 feet flat, with positive fall on each side. Positive fall is considered to be 0.10 feet in 20 feet. The minimum fall from the rear property line to the front IS 0.50 feet. I NEED ELEVATIONS ON THE FRONT PROPERTY LINEI NEED ELEVATION ON THE BACK PATIO .Drainage from the structure is to be a 6 inch (5%) minimum slope for the first 10’.(E) I NEED ELEVATION ON THE BACK PATIO .Drainage from the structure is to be a 6 inch (5%) minimum slope for the first 10’.(E) LEFT SIDE SWALE IS TOO HIGH STOPING THE FLOW OF THE WATER MATCH EXISTING GRADE 7/10/2023 - PREVIOUS INSPECTION NOTES 7/10/23= BOTH SIDES NEED TO SHOW POSITEVE FALL RIGHT SIDE AND LEFT SIDE YOU NEED TO SUBMIT A NEW SURVEY SHOING POSITIVE FALL TO THE FRONT. The tolerance alongside lot lines is no more than 20 feet flat, with positive fall on each side. Positive fall is considered to be 0.10 feet in 20 feet. The minimum fall from the rear property line to the front is 0.50 feet. Sec 300.01 (A)(1)(C)(6). Unless specifically stated the subject lot must drain from back to front or a portion may be drained to an adjacent City drainage feature. (B) 7/5/2023 - PREVIOUS INSPECTION NOTES 07/05/23 NEED TO SHOW POSITIVE DRAINAGE FROM REAR TO FRONT OF PROPERTY NEED TO LIST ALL FFE FOR ADJACENT PROPERTIES. NEED TO SHOW ALL CULVERT ELEVATIONS WITHIN 130 FT OF LOT LINE. _________________________________________________________________________________________________________________________ 6/26/2023 - PREVIOUS INSPECTION NOTES 06/26/23 NEED TO PROVIDE ELEVATION SHOTS ON THE LEFT SIDE INSIDE PROPERTY LINE IN 20' INTERVALS SO WE CAN DETERMINE IF THERE IS POSITIVE DRAINAGE FROM REAR TO FRONT WITHOUT ANY ADVERSE DRAINAGE TO ADJACENT PROPERTY OWNER. SITE PLAN INDICATES INSIDE DRAINAGE, WE DO NOT HAVE ANY SHOTS TO DETERMINE DRAINAGE FLOW. Inspector Notes from Inspection 9270 5/22/23=CORRECTION WERE MADE AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS BEFORE POURING. MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 5/18/2023 - PREVIOUS INSPECTION NOTES 5/18/23 MITER END ON THE RIGHT SIDE NEED TO BE AT 8 FT FROM THE ROAD EDGE NEED TO CHECK THE ELEVATION AGAIN. +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 5/17/2023 - PREVIOUS INSPECTION NOTES CANCELLED BY CM DO TO NOT FORMED ALL THE WAY -------------------------------------------------------------------------- 5/16/2023 - PREVIOUS INSPECTION NOTES NOT READY | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 07/26/2023 | Disapproved - NO FEE | GBERTOLA |
| Note: 7/26/23= ELEVATIONS ON THE BACK YEAR RUNNING FLAT.The tolerance along side lot lines is no more than 20 feet flat, with positive fall on each side. Positive fall is considered to be 0.10 feet in 20 feet. The minimum fall from the rear property line to the front IS 0.50 feet. The subject lots drainage must not negatively impact any adjacent property. in the back yard tour to the property line I NEED ELEVATIONS ON THE FRONT PROPERTY LINE The tolerance along side lot lines is no more than 20 feet flat, with positive fall on each side. Positive fall is considered to be 0.10 feet in 20 feet. The minimum fall from the rear property line to the front is 0.50 feet. I NEED ELEVATION ON THE BACK PATIO .Drainage from the structure is to be a 6 inch (5%) minimum slope for the first 10’.(E) LEFT SIDE SWALE IS TOO HIGH STOPING THE FLOW OF THE WATER MATCH EXISTING GRADE 7/10/2023 - PREVIOUS INSPECTION NOTES 7/10/23= BOTH SIDES NEED TO SHOW POSITEVE FALL RIGHT SIDE AND LEFT SIDE YOU NEED TO SUBMIT A NEW SURVEY SHOING POSITIVE FALL TO THE FRONT. The tolerance alongside lot lines is no more than 20 feet flat, with positive fall on each side. Positive fall is considered to be 0.10 feet in 20 feet. The minimum fall from the rear property line to the front is 0.50 feet. Sec 300.01 (A)(1)(C)(6). Unless specifically stated the subject lot must drain from back to front or a portion may be drained to an adjacent City drainage feature. (B) 7/5/2023 - PREVIOUS INSPECTION NOTES 07/05/23 NEED TO SHOW POSITIVE DRAINAGE FROM REAR TO FRONT OF PROPERTY NEED TO LIST ALL FFE FOR ADJACENT PROPERTIES. NEED TO SHOW ALL CULVERT ELEVATIONS WITHIN 130 FT OF LOT LINE. _________________________________________________________________________________________________________________________ 6/26/2023 - PREVIOUS INSPECTION NOTES 06/26/23 NEED TO PROVIDE ELEVATION SHOTS ON THE LEFT SIDE INSIDE PROPERTY LINE IN 20' INTERVALS SO WE CAN DETERMINE IF THERE IS POSITIVE DRAINAGE FROM REAR TO FRONT WITHOUT ANY ADVERSE DRAINAGE TO ADJACENT PROPERTY OWNER. SITE PLAN INDICATES INSIDE DRAINAGE, WE DO NOT HAVE ANY SHOTS TO DETERMINE DRAINAGE FLOW. Inspector Notes from Inspection 9270 5/22/23=CORRECTION WERE MADE AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS BEFORE POURING. MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 5/18/2023 - PREVIOUS INSPECTION NOTES 5/18/23 MITER END ON THE RIGHT SIDE NEED TO BE AT 8 FT FROM THE ROAD EDGE NEED TO CHECK THE ELEVATION AGAIN. +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 5/17/2023 - PREVIOUS INSPECTION NOTES CANCELLED BY CM DO TO NOT FORMED ALL THE WAY -------------------------------------------------------------------------- 5/16/2023 - PREVIOUS INSPECTION NOTES NOT READY | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 07/10/2023 | Disapproved -FEE REQUIRED | GBERTOLA |
| Note: 7/10/23= BOTH SIDES NEED TO SHOW POSITEVE FALL RIGHT SIDE AND LEFT SIDE YOU NEED TO SUBMIT A NEW SURVEY SHOING POSITIVE FALL TO THE FRONT. The tolerance alongside lot lines is no more than 20 feet flat, with positive fall on each side. Positive fall is considered to be 0.10 feet in 20 feet. The minimum fall from the rear property line to the front is 0.50 feet. Sec 300.01 (A)(1)(C)(6). Unless specifically stated the subject lot must drain from back to front or a portion may be drained to an adjacent City drainage feature. (B) 7/5/2023 - PREVIOUS INSPECTION NOTES 07/05/23 NEED TO SHOW POSITIVE DRAINAGE FROM REAR TO FRONT OF PROPERTY NEED TO LIST ALL FFE FOR ADJACENT PROPERTIES. NEED TO SHOW ALL CULVERT ELEVATIONS WITHIN 130 FT OF LOT LINE. _________________________________________________________________________________________________________________________ 6/26/2023 - PREVIOUS INSPECTION NOTES 06/26/23 NEED TO PROVIDE ELEVATION SHOTS ON THE LEFT SIDE INSIDE PROPERTY LINE IN 20' INTERVALS SO WE CAN DETERMINE IF THERE IS POSITIVE DRAINAGE FROM REAR TO FRONT WITHOUT ANY ADVERSE DRAINAGE TO ADJACENT PROPERTY OWNER. SITE PLAN INDICATES INSIDE DRAINAGE, WE DO NOT HAVE ANY SHOTS TO DETERMINE DRAINAGE FLOW. Inspector Notes from Inspection 9270 5/22/23=CORRECTION WERE MADE AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS BEFORE POURING. MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 5/18/2023 - PREVIOUS INSPECTION NOTES 5/18/23 MITER END ON THE RIGHT SIDE NEED TO BE AT 8 FT FROM THE ROAD EDGE NEED TO CHECK THE ELEVATION AGAIN. +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 5/17/2023 - PREVIOUS INSPECTION NOTES CANCELLED BY CM DO TO NOT FORMED ALL THE WAY -------------------------------------------------------------------------- 5/16/2023 - PREVIOUS INSPECTION NOTES NOT READY | |||
| ROW FIELD SURVEY /GRADING CERTIFICATION | 07/10/2023 | Disapproved - NO FEE | GBERTOLA |
| Note: 7/10/23= BOTH SIDES NEED TO SHOW POSITEVE FALL RIGHT SIDE AND LEFT SIDE YOU NEED TO SUBMIT A NEW SURVEY SHOING POSITIVE FALL TO THE FRONT. The tolerance alongside lot lines is no more than 20 feet flat, with positive fall on each side. Positive fall is considered to be 0.10 feet in 20 feet. The minimum fall from the rear property line to the front is 0.50 feet. Sec 300.01 (A)(1)(C)(6). Unless specifically stated the subject lot must drain from back to front or a portion may be drained to an adjacent City drainage feature. (B) | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 07/05/2023 | Disapproved - NO FEE | FSLADISH |
| Note: 07/05/23 NEED TO SHOW POSITIVE DRAINAGE FROM REAR TO FRONT OF PROPERTY NEED TO LIST ALL FFE FOR ADJACENT PROPERTIES. NEED TO SHOW ALL CULVERT ELEVATIONS WITHIN 130 FT OF LOT LINE. Lot must drain. Section 300.01 (A)(1)(C)(6) Section 300.01 (A)(1)(C)(6). Unless specifically stated the subject lot must drain from back to front or a portion may be drained to an adjacent City drainage feature. (B) _________________________________________________________________________________________________________________________ 6/26/2023 - PREVIOUS INSPECTION NOTES 06/26/23 NEED TO PROVIDE ELEVATION SHOTS ON THE LEFT SIDE INSIDE PROPERTY LINE IN 20' INTERVALS SO WE CAN DETERMINE IF THERE IS POSITIVE DRAINAGE FROM REAR TO FRONT WITHOUT ANY ADVERSE DRAINAGE TO ADJACENT PROPERTY OWNER. SITE PLAN INDICATES INSIDE DRAINAGE, WE DO NOT HAVE ANY SHOTS TO DETERMINE DRAINAGE FLOW. Inspector Notes from Inspection 9270 5/22/23=CORRECTION WERE MADE AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS BEFORE POURING. MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 5/18/2023 - PREVIOUS INSPECTION NOTES 5/18/23 MITER END ON THE RIGHT SIDE NEED TO BE AT 8 FT FROM THE ROAD EDGE NEED TO CHECK THE ELEVATION AGAIN. +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 5/17/2023 - PREVIOUS INSPECTION NOTES CANCELLED BY CM DO TO NOT FORMED ALL THE WAY -------------------------------------------------------------------------- 5/16/2023 - PREVIOUS INSPECTION NOTES NOT READY | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 06/26/2023 | Disapproved - NO FEE | FSLADISH |
| Note: 06/26/23 NEED TO PROVIDE ELEVATION SHOTS ON THE LEFT SIDE INSIDE PROPERTY LINE IN 20' INTERVALS SO WE CAN DETERMINE IF THERE IS POSITIVE DRAINAGE FROM REAR TO FRONT WITHOUT ANY ADVERSE DRAINAGE TO ADJACENT PROPERTY OWNER. SITE PLAN INDICATES INSIDE DRAINAGE, WE DO NOT HAVE ANY SHOTS TO DETERMINE DRAINAGE FLOW. Final elevations on a 20’ grid inside property lines. (E) E.Land Development Code Technical Manual, Section 300.01 (D)(3) Inspector Notes from Inspection 9270 5/22/23=CORRECTION WERE MADE AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS BEFORE POURING. MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 5/18/2023 - PREVIOUS INSPECTION NOTES 5/18/23 MITER END ON THE RIGHT SIDE NEED TO BE AT 8 FT FROM THE ROAD EDGE NEED TO CHECK THE ELEVATION AGAIN. +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 5/17/2023 - PREVIOUS INSPECTION NOTES CANCELLED BY CM DO TO NOT FORMED ALL THE WAY -------------------------------------------------------------------------- 5/16/2023 - PREVIOUS INSPECTION NOTES NOT READY | |||
| ELECTRIC - EARLY POWER | 06/26/2023 | APPROVED - AS NOTED | KSANDOE |
| Note: Emailed FPL @ 1314. Release Power 6/20/2023 - PREVIOUS INSPECTION NOTES Protection for ground. Ground wire needs to be protected Disconnect for AC cannot be behind unit | |||
| ELECTRIC - EARLY POWER | 06/20/2023 | Disapproved - NO FEE | KSANDOE |
| Note: Protection for ground. Ground wire needs to be protected Disconnect for AC cannot be behind unit | |||
| ROW- PRE-APRON (PRE-POUR) | 05/22/2023 | APPROVED - AS NOTED | GBERTOLA |
| Note: 5/22/23=CORRECTION WERE MADE AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS BEFORE POURING. MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 5/18/2023 - PREVIOUS INSPECTION NOTES 5/18/23 MITER END ON THE RIGHT SIDE NEED TO BE AT 8 FT FROM THE ROAD EDGE NEED TO CHECK THE ELEVATION AGAIN. +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 5/17/2023 - PREVIOUS INSPECTION NOTES CANCELLED BY CM DO TO NOT FORMED ALL THE WAY -------------------------------------------------------------------------- 5/16/2023 - PREVIOUS INSPECTION NOTES NOT READY | |||
| ROW- PRE-APRON (PRE-POUR) | 05/18/2023 | Disapproved -FEE REQUIRED | GBERTOLA |
| Note: 5/18/23 MITER END ON THE RIGHT SIDE NEED TO BE AT 8 FT FROM THE ROAD EDGE NEED TO CHECK THE ELEVATION AGAIN. NEED TO HAVE POSITIVE FLOW TO THE FRONT. FROM BOTH SIDE OF THE APRON TO THE DRIVEWAY WATER IS GOING BACKWARD. CULVERT PIPE IS GOOD +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 5/17/2023 - PREVIOUS INSPECTION NOTES CANCELLED BY CM DO TO NOT FORMED ALL THE WAY -------------------------------------------------------------------------- 5/16/2023 - PREVIOUS INSPECTION NOTES NOT READY | |||
| ROW- PRE-APRON (PRE-POUR) | 05/17/2023 | CANCELLED BY APPLICANT | PFLANAGAN |
| Note: CANCELLED BY CM DO TO NOT FORMED ALL THE WAY -------------------------------------------------------------------------- 5/16/2023 - PREVIOUS INSPECTION NOTES NOT READY | |||
| ROW- PRE-APRON (PRE-POUR) | 05/16/2023 | CANCELLED BY APPLICANT | PFLANAGAN |
| Note: NOT READY | |||
| GRAVITY SEWER TEST | 05/08/2023 | Disapproved - NO FEE | KSANDOE |
| Note: Still not holding water 5/5/2023 - PREVIOUS INSPECTION NOTES Not holding water. Test failed 5/4/2023 - PREVIOUS INSPECTION NOTES Trenches flooded. Plumbing not holding water. Unable to see connections | |||
| GRAVITY SEWER TEST | 05/08/2023 | APPROVED | KSANDOE |
| Note: 5/8/2023 - PREVIOUS INSPECTION NOTES Still not holding water 5/5/2023 - PREVIOUS INSPECTION NOTES Not holding water. Test failed 5/4/2023 - PREVIOUS INSPECTION NOTES Trenches flooded. Plumbing not holding water. Unable to see connections | |||
| GRAVITY SEWER TEST | 05/05/2023 | Disapproved -FEE REQUIRED | KSANDOE |
| Note: Not holding water. Test failed 5/4/2023 - PREVIOUS INSPECTION NOTES Trenches flooded. Plumbing not holding water. Unable to see connections | |||
| U - SEWER TIE IN | 05/05/2023 | APPROVED | KSANDOE |
| Note: 5/4/2023 - PREVIOUS INSPECTION NOTES Trenches flooded. Plumbing not holding water. Unable to see connections | |||
| U - SEWER TIE IN | 05/04/2023 | Disapproved - NO FEE | KSANDOE |
| Note: Trenches flooded. Plumbing not holding water. Unable to see connections | |||
| GRAVITY SEWER TEST | 05/04/2023 | Disapproved - NO FEE | KSANDOE |
| Note: Trenches flooded. Plumbing not holding water. Unable to see connections | |||
| PEP TANK INSTALLATION REQUEST | 04/24/2023 | APPROVED | CSTONE |
| Note: 4/19/2023 4:02:21 PM- PREVIOUS INSPECTION NOTES 4/19/2023 Dumpster in the way of tank. | |||
| PEP TANK INSTALLATION REQUEST | 04/19/2023 | Disapproved - NO FEE | TSCHWEERS |
| Note: 4/19/2023 Dumpster in the way of tank. | |||
| INSULATION | 04/10/2023 | APPROVED | KSANDOE |
| Note: Inspector Notes from Inspection 2420 Front doors need to be installed. Check at insulation 4/3/2023 - PREVIOUS INSPECTION NOTES not ready for inspection, (afternoon inspection requested and granted) 1. SER not installed 2. Nail plates not installedNEC 300.4 a 1 3. Hot conductors in panel box not phased out. NEC.210.5(C). Inspection Stopped | |||
| ALL ROUGH | 04/05/2023 | APPROVED - AS NOTED | KSANDOE |
| Note: Front doors need to be installed. Check at insulation 4/3/2023 - PREVIOUS INSPECTION NOTES not ready for inspection, (afternoon inspection requested and granted) 1. SER not installed 2. Nail plates not installedNEC 300.4 a 1 3. Hot conductors in panel box not phased out. NEC.210.5(C). Inspection Stopped | |||
| ALL ROUGH | 04/03/2023 | Disapproved -FEE REQUIRED | LMILLER |
| Note: not ready for inspection, (afternoon inspection requested and granted) 1. SER not installed 2. Nail plates not installedNEC 300.4 a 1 3. Hot conductors in panel box not phased out. NEC.210.5(C). Inspection Stopped | |||
| ALL ROUGH | 03/31/2023 | CANCELLED BY APPLICANT | WEB |
| LATH/BRICK/ WATER BARRIER | 03/30/2023 | APPROVED | KSANDOE |
| FIREWALL DRYWALL NAILING | 03/22/2023 | CANCELLED BY INSPECTOR | KSANDOE |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 03/21/2023 | APPROVED | KSANDOE |
| Note: 3/15/2023 - PREVIOUS INSPECTION NOTES 3/14/2023 - PREVIOUS INSPECTION NOTES Roof sheathing only passed | |||
| ROOF VALLEY & METAL | 03/16/2023 | APPROVED | BTAYLOR |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 03/15/2023 | CANCELLED BY APPLICANT | KSANDOE |
| Note: 3/14/2023 - PREVIOUS INSPECTION NOTES Roof sheathing only passed | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 03/14/2023 | PARTIALLY APPROVED | KSANDOE |
| Note: Roof sheathing only passed | |||
| WALL SHEATHING | 03/10/2023 | APPROVED | KSANDOE |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 03/10/2023 | CANCELLED BY APPLICANT | WEB |
| FOUND SURVEY APPROVED (OFFICE) | 03/08/2023 | APPROVED | TBAKER |
| ELECTRIC TEMP POLE | 03/07/2023 | APPROVED | JWALKER |
| TIE BEAM / LINTEL | 03/02/2023 | APPROVED | KSANDOE |
| Note: 3/1/2023 - PREVIOUS INSPECTION NOTES Missing dowel, entry, Unit B | |||
| TIE BEAM / LINTEL | 03/01/2023 | Disapproved - NO FEE | KSANDOE |
| Note: Missing dowel, entry, Unit B | |||
| MONOLITHIC SLAB | 02/22/2023 | APPROVED | KSANDOE |
| Note: 2/21/2023 - PREVIOUS INSPECTION NOTES Front right side Unit B caved in, steel chairs collapsed Replace chairs, clean out dirt, and ensure 3" minimum clearance for steel. | |||
| MONOLITHIC SLAB | 02/21/2023 | Disapproved - NO FEE | KSANDOE |
| Note: Front right side Unit B caved in, steel chairs collapsed Replace chairs, clean out dirt, and ensure 3" minimum clearance for steel. | |||
| MONOLITHIC SLAB | 02/21/2023 | CANCELLED BY APPLICANT | WEB |
| MONOLITHIC SLAB | 02/17/2023 | CANCELLED BY APPLICANT | WEB |
| WATER METER INSTALLATION REQUEST | 02/16/2023 | APPROVED | TSCHWEERS |
| PLUMBING 1ST ROUGH UNDERGROUND | 02/15/2023 | APPROVED | MGIBSON |
| Note: New inspection due to canceled inspection 2/9/2023 - PREVIOUS INSPECTION NOTES WRONG ADDRESS CALLED IN , SHOULD HAVE BEEN 41 PONCE DELEON, | |||
| PLUMBING 1ST ROUGH UNDERGROUND | 02/10/2023 | CANCELLED BY APPLICANT | WEB |
| Note: 2/9/2023 - PREVIOUS INSPECTION NOTES WRONG ADDRESS CALLED IN , SHOULD HAVE BEEN 41 PONCE DELEON, | |||
| PLUMBING 1ST ROUGH UNDERGROUND | 02/09/2023 | Disapproved - NO FEE | MGIBSON |
| Note: WRONG ADDRESS CALLED IN , SHOULD HAVE BEEN 41 PONCE DELEON, |
Review History
| Department | Status | Date In | Date Out |
| MECH | COMPLETE | 07/21/2023 | 07/24/2023 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| MECH | HOLD | 07/10/2023 | 07/11/2023 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Provide project summary page for Side B | |||
| MECH | HOLD | 06/30/2023 | 07/06/2023 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM 1. Energy Calcs need to be signed by the owner/ owner agent below the preparer per R103.1.1.2 FBC Energy Conservation 2020 7Th edition 2. Provide adjacent wall insulation and type on Energy calcs. 3. TMY site on Energy calcs needs to be Daytona Beach | |||
| ENGIN1 | COMPLETE | 03/22/2023 | 03/22/2023 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 03/22/2023 | 03/22/2023 |
| Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 03/20/2023 | 03/20/2023 |
| Note: Released By: PATRICK BUCKLEY - (386)986-3786 - PBUCKLEY@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 03/20/2023 | 03/20/2023 |
| Note: Released By: PATRICK BUCKLEY - (386)986-3786 - PBUCKLEY@PALMCOASTGOV.COM | |||
| BLD | HOLD | 03/14/2023 | 03/15/2023 |
| Note: Held By: PATRICK BUCKLEY - (386)986-3786 - PBUCKLEY@PALMCOASTGOV.COM Submitted detail does not match actual conditions. Detail shows shaft liner firewall from foundation through a two story home to roof deck of roofs of different height. Actual conditions indicate a one story home with a CMU wall to the ceiling height. Firewall detail would only need to be from top of CMU wall to underside of roof sheathing. Inspector has indicated something entirely different is being constructed in the field. Detail needs to match actual construction. | |||
| BLD | HOLD | 03/09/2023 | 03/09/2023 |
| Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Plans need to be digitally signed and sealed. | |||
| ENGIN1 | COMPLETE | 03/08/2023 | 03/08/2023 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 03/08/2023 | 03/08/2023 |
| Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 02/15/2023 | 02/22/2023 |
| Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 01/31/2023 | 01/31/2023 |
| Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM | |||
| BLD | HOLD | 01/24/2023 | 01/26/2023 |
| Note: Held By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM All comments below per the 2020 Florida Building Code PLAN REVIEW COMMENTS: 1. Provide a UL Listed wall between the units. R302.3. 2. Proposed windows are aluminum framed. A revision to the Energy Forms is required to reflect the correct windows that are to be installed. | |||
| ZON | COMPLETE | 01/24/2023 | 01/24/2023 |
| Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 01/24/2023 | 01/24/2023 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 01/24/2023 | 01/31/2023 |
| Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 01/24/2023 | 01/24/2023 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| BLD | HOLD | 01/13/2023 | 01/17/2023 |
| Note: Held By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM All comments below per the 2020 Florida Building Code PLAN REVIEW COMMENTS: 1. Provide a UL Listed wall between the units. R302.3. 2. Proposed windows are aluminum framed. A revision to the Energy Forms is required to reflect the correct windows that are to be installed. | |||
| CUSVC | COMPLETE | 01/13/2023 | 01/19/2023 |
| Note: Released By: LISA ASBILL - - lasbill@palmcoastgov.com | |||
| ELEC | COMPLETE | 01/13/2023 | 01/13/2023 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 01/13/2023 | 01/13/2023 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| LOCATE | COMPLETE | 01/13/2023 | 01/19/2023 |
| Note: Released By: CANDACE STONE - - CSTONE@PALMCOASTGOV.COM | |||
| MECH | HOLD | 01/13/2023 | 01/17/2023 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM 1. Clarify insulation on block walls. Energy calcs show 11.6. 3/4 inch foam board is R5 typically. Show insulation on plans. 2. Energy calcs need to be signed by the builder. | |||
| SW1 | HOLD | 01/13/2023 | 01/23/2023 |
| Note: Held By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM NEED TO HAVE PROPOSED SOD ELEVATIONS ON ALL FOUR CORNERS OF THE STRUCTURE TO DETERMIND IF FFE IS THE MINIMUM HEIGHT ABOVE THE SOD ELEVATIONS | |||
| ZON | HOLD | 01/13/2023 | 01/17/2023 |
| Note: Held By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM Site plan : Please provide the entire width of the drive way. Leagel information is incorrect. The lot number should be 23 | |||
| SWALE | COMPLETE | 01/13/2023 | 04/25/2023 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| CONTRACTOR CHANGE | ¤20.00 | 09/28/2023 |
| SW ENG REINSPECTION 20 | ¤20.00 | 09/28/2023 |
| SW ENG REINSPECTION 20 | ¤20.00 | 09/28/2023 |
| SW ENG REINSPECTION 30 | ¤30.00 | 09/28/2023 |
| PLAN REVIEW - REVISION | ¤32.50 | 09/28/2023 |
| PLAN REVIEW - REVISION | ¤65.00 | 09/28/2023 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 09/28/2023 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 09/28/2023 |
| CONNECTION FEES | ¤2,332.52 | 02/02/2023 |
| SW ENG - REVIEW 20 | ¤20.00 | 02/02/2023 |
| SW ENG RES REVIEW 200 | ¤200.00 | 02/02/2023 |
| TRANS IMPACT FEE ADMIN | ¤84.36 | 02/02/2023 |
| TRANS IMPACT FEE ADMIN | (¤84.36) | 02/02/2023 |
| SEWER CREDIT | (¤1,300.00) | 02/02/2023 |
| SEWER INSPECTION | ¤25.00 | 02/02/2023 |
| SEWER CAPITAL FACILITY | ¤10,689.64 | 02/02/2023 |
| WATER CAPITAL FACILITY FEE | ¤7,847.76 | 02/02/2023 |
| SITE PLAN 30 | ¤30.00 | 02/02/2023 |
| WATER-METER | ¤505.39 | 02/02/2023 |
| WATER- TURN ON | ¤25.00 | 02/02/2023 |
| WATER- TURN ON | ¤50.00 | 02/02/2023 |
| ADJUSTMENT 50% | (¤570.98) | 02/02/2023 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 02/02/2023 |
| INSPECTION - RESIDENTIAL | ¤866.25 | 02/02/2023 |
| PLAN REVIEW - RESIDENTIAL | ¤245.70 | 02/02/2023 |
| PLAN REVIEW - REVISION | ¤32.50 | 02/02/2023 |
| FIRE IMPACT FEE ADMIN | ¤25.23 | 02/02/2023 |
| FIRE IMPACT FEE ADMIN | (¤25.23) | 02/02/2023 |
| FC IMPACT FEE EMS | ¤124.00 | 02/02/2023 |
| IMPACT FEE FIRE | ¤841.04 | 02/02/2023 |
| FC IMPACT FEE LAW ENFORCEMENT | ¤436.00 | 02/02/2023 |
| FC IMPACT FEE LIBRARY | ¤536.00 | 02/02/2023 |
| IMPACT FEE PARKS | ¤3,538.30 | 02/02/2023 |
| IMPACT FEE SCHOOL | ¤10,900.00 | 02/02/2023 |
| IMPACT FEE TRANSPORTATION | ¤2,812.00 | 02/02/2023 |
| WATER -IRRIGATION INSPECTION | ¤50.00 | 02/02/2023 |
| WATER -IRRIGATION INSPECTION | ¤25.00 | 02/02/2023 |
| PARKS IMPACT FEE ADMIN | ¤106.15 | 02/02/2023 |
| PARKS IMPACT FEE ADMIN | (¤106.15) | 02/02/2023 |
| SURCHARGE FS 533.721 | ¤3.64 | 02/02/2023 |
| SURCHARGE - FS 468.631 | ¤5.47 | 02/02/2023 |
| SW ENG - FOUNDATION SURVEY | ¤20.00 | 02/02/2023 |
| SW ENG INSPECTION 80 | ¤80.00 | 02/02/2023 |
| SW ENG PRE APRON | ¤30.00 | 02/02/2023 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤40,697.73 |