I want to search for...

Permit #2023010770

Permit Details

Status: COED

Parcel Id: 07-11-31-7058-00690-0130
CONDITIONED SPACE: 2392 sqft
GARAGE: 622 sqft
SCREEN PORCH (SOLID ROOF) : 72 sqft
OPENED PORCH (WITH ROOF) : 288 sqft
Total Square Footage: 3374 sqft
Block: 00690
Subdivision: 2215 - SECTION 58-SEMINOLE PARK
Job Phone: 386-627-0430
Location Address: 13 SETON PL
Type: DU - DUPLEX
Issue Date: 02/16/2023
NOC: RECORDED
Applicant name: ANNA WIKTORIA LISOWSKI
Owner: SIEDLECKI SEBASTIAN & MARTA PYCIA TIC

Address

27 SCHOOLHOUSE ROAD

LEVITTOWN, NY 11756

Lot: 0130
Contracted Stated Job Value: ¤350,000.00
Job Description: Duplex
Type: CN

Contractor

GOLDEN FOX HOME REMODELING, INC
Status Location Address State License Number Phone
ACTIVE

72 HERNANDEZ AVE

PALM COAST, FL 32137

CBC1259266 (Exp: 08/31/2026) 386-627-0430

Sub Contractors

DANIEL J LUSINSKI
Status Location Address Mailing Address State License Number Phone
ACTIVE

389 PALM COAST PARKWAY SW

PALM COAST, FL 32137

#4

PALM COAST, FL 32137

CCC1330133 (Exp: 08/31/2026) 386-338-7926
JUAN CARLOS GONZALEZ
Status Location Address State License Number
ACTIVE

1328 COUNTY ROAD 308

CRESCENT CITY, FL 32112

RF11067806 (Exp: 08/31/2027)
WILLIAM TODD SIKES
Status Location Address State License Number Phone
ACTIVE

83 PORT ROYAL DR

ST AUGUSTINE, FL 32084

EC0002726 (Exp: 08/31/2026) 904-762-8762
SCOTT H STILLWELL
Status Location Address State License Number Phone
ACTIVE

4500 US 1 UNIT 206

BUNNELL, FL 32110

CAC1819433 (Exp: 08/31/2026) 386-864-4404

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 01/04/2024 FINAL APPROVED BTAYLOR
ROW - FINAL INSPECTION 12/21/2023 APPROVED RGROSS
Note: 12/12/2023 - PREVIOUS INSPECTION NOTES 12/12/23 AFTER WALKING PROPERTY THE SOD AROUND THE HOUSE NEEDS TO MATCH GRADE OF OLDER SOD. THERE IS A STEP UP THAT WILL IMPEED THE FLOW FROM THE DRAINAGE COVEYANCE _________________________________________________________________________________ 12/11/23 ** WALKED PROPERTY DRAINAGE WILL WORK AS INDICATED ON FINAL SURVEY. At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved
U -UTILITY RESIDENTIAL FINAL 12/12/2023 FINAL APPROVED JHARDING
ROW - FINAL INSPECTION 12/12/2023 Disapproved - NO FEE TPOLACEK
Note: 12/12/23 AFTER WALKING PROPERTY THE SOD AROUND THE HOUSE NEEDS TO MATCH GRADE OF OLDER SOD. THERE IS A STEP UP THAT WILL IMPEED THE FLOW FROM THE DRAINAGE COVEYANCE _________________________________________________________________________________ 12/11/23 ** WALKED PROPERTY DRAINAGE WILL WORK AS INDICATED ON FINAL SURVEY. At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved
U-CROSS CONNECTION 12/12/2023 APPROVED - AS NOTED JHARDING
Note: No irrigation, no cross connections.
ROW - FINAL APRON (AFTER POUR) 12/12/2023 APPROVED TPOLACEK
Note: 12/12/23 At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved. 12/11/23 ** WALKED PROPERTY DRAINAGE WILL WORK AS INDICATED ON FINAL SURVEY. At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved
ROW- FINAL SURVEY/GRADING CERTIFICATION 12/11/2023 APPROVED TPOLACEK
Note: 12/11/23 ** WALKED PROPERTY DRAINAGE WILL WORK AS INDICATED ON FINAL SURVEY. At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved
ROW FIELD SURVEY /GRADING CERTIFICATION 12/11/2023 APPROVED - AS NOTED TPOLACEK
Note: 12/11/23 ** WALKED PROPERTY DRAINAGE WILL WORK AS INDICATED ON FINAL SURVEY. At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved
ROW- PRE-APRON (PRE-POUR) 11/02/2023 APPROVED PFLANAGAN
Note: IT'S YOUR RESPONSIBILITY TO CHECK THE CULVERT ELEVATIONS BEFORE POURING CONCRETE ALL CONCRETE NEEDS TO BE A MINIMUM OF 3000PSI WITH FIBER OR WITH METAL MESH IN THE CONCRETE TO MEET ALL CITY'S STANDARTS At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved. ----------------------------------------------------------------------------------- 11/1/2023 - PREVIOUS INSPECTION NOTES CONTRACTOR ON SITE EXPLAINDED WHAT NEEDS TO BE DONE 1) THE CULVERT PIPE IS TO FAR FROM THE EDGE OF ROAD Swale Plan #2. The swale centerline is typically located 5 feet from e.o.p. in cul de sacs. Culverts in cul de sacs may require a 22.5° elbow. 2) NEED TO HAVE 4" FROM MITER CUT TO THE DRIVEWAY
ROW- PRE-APRON (PRE-POUR) 11/01/2023 Disapproved -FEE REQUIRED PFLANAGAN
Note: CONTRACTOR ON SITE EXPLAINDED WHAT NEEDS TO BE DONE 1) THE CULVERT PIPE IS TO FAR FROM THE EDGE OF ROAD Swale Plan #2. The swale centerline is typically located 5 feet from e.o.p. in cul de sacs. Culverts in cul de sacs may require a 22.5° elbow. 2) NEED TO HAVE 4" FROM MITER CUT TO THE DRIVEWAY
ELECTRIC - EARLY POWER 09/21/2023 APPROVED - AS NOTED BTAYLOR
Note: 9-21-23 1. Emailed FPL at 1:05.
GRAVITY SEWER TEST 09/20/2023 APPROVED - AS NOTED MGIBSON
Note: THIS WAS A VIRTUAL INSPECTION
U - SEWER TIE IN 09/20/2023 APPROVED - AS NOTED MGIBSON
Note: THIS WAS A VIRTUAL INSPECTION
INSULATION 08/15/2023 APPROVED BTAYLOR
ALL ROUGH 08/07/2023 CANCELLED BY APPLICANT WEB
Note: 7/27/2023 - PREVIOUS INSPECTION NOTES 7/27/23: Job box needs attention. Jumbled up & damaged prints in box. No Energy calcs or Product approval sheets. Inspection stopped. ** Product approval revision for different windows & doors has only been accepted not approved yet. Inspection Windows checked for proper anchoring based on DBPR installation instructions for FPA#s stickers on windows & doors. Wires phased out. Plumbing 5ft. head & pressure good at time of inspection. Linesets not run through sleeve at this inspection.
ALL ROUGH 08/07/2023 APPROVED BTAYLOR
Note: New inspection due to canceled inspection 7/27/2023 - PREVIOUS INSPECTION NOTES 7/27/23: Job box needs attention. Jumbled up & damaged prints in box. No Energy calcs or Product approval sheets. Inspection stopped. ** Product approval revision for different windows & doors has only been accepted not approved yet. Inspection Windows checked for proper anchoring based on DBPR installation instructions for FPA#s stickers on windows & doors. Wires phased out. Plumbing 5ft. head & pressure good at time of inspection. Linesets not run through sleeve at this inspection.
ALL ROUGH 07/27/2023 Disapproved -FEE REQUIRED RSIMS
Note: 7/27/23: Job box needs attention. Jumbled up & damaged prints in box. No Energy calcs or Product approval sheets. Inspection stopped. ** Product approval revision for different windows & doors has only been accepted not approved yet. Inspection Windows checked for proper anchoring based on DBPR installation instructions for FPA#s stickers on windows & doors. Wires phased out. Plumbing 5ft. head & pressure good at time of inspection. Linesets not run through sleeve at this inspection.
LATH/BRICK/ WATER BARRIER 07/21/2023 APPROVED MKRASKI
FIREWALL FINAL 06/16/2023 APPROVED BTAYLOR
ROOF VALLEY & METAL 06/15/2023 APPROVED BTAYLOR
Note: 6/14/2023 - PREVIOUS INSPECTION NOTES 6/9/2023 - PREVIOUS INSPECTION NOTES 6-9-23 1. Roof shingled. 6-14-23 1. Roof has been shingled before inspection has been performed.
ROOF VALLEY & METAL 06/14/2023 Disapproved -FEE REQUIRED BTAYLOR
Note: 6/9/2023 - PREVIOUS INSPECTION NOTES 6-9-23 1. Roof shingled. 6-14-23 1. Roof has been shingled before inspection has been performed.
FIREWALL DRYWALL NAILING 06/14/2023 APPROVED BTAYLOR
WALL SHEATHING 06/09/2023 APPROVED BTAYLOR
ROOF SHEATHING / BRACES/TIES/DOWN CELL 06/09/2023 APPROVED BTAYLOR
ROOF VALLEY & METAL 06/09/2023 Disapproved -FEE REQUIRED BTAYLOR
Note: 6-9-23 1. Roof shingled.
FOUND SURVEY APPROVED (OFFICE) 06/08/2023 APPROVED TBAKER
TIE BEAM / LINTEL 05/03/2023 APPROVED BTAYLOR
MONOLITHIC SLAB 04/14/2023 APPROVED BTAYLOR
PLUMBING 1ST ROUGH UNDERGROUND 04/11/2023 APPROVED BTAYLOR
PLUMBING 1ST ROUGH UNDERGROUND 04/10/2023 CANCELLED BY APPLICANT WEB
WATER METER INSTALLATION REQUEST 03/08/2023 APPROVED CSTONE

Review History

Department Status Date In Date Out
SW1 COMPLETE 10/02/2023 10/03/2023
Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM
ENGIN1 COMPLETE 10/02/2023 10/03/2023
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
SW1 COMPLETE 10/02/2023 10/03/2023
Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM
ZON COMPLETE 10/02/2023 10/02/2023
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
ENGIN1 COMPLETE 09/25/2023 09/26/2023
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
SW1 HOLD 09/25/2023 09/28/2023
Note: Held By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM NEED TO MAKE RIGHT SIDE DRAINAGE PATTERN AT COMMON SWALE DO TO NEW CONSTRUCTION ON THE RIGHT ADJACENT LOT
ZON COMPLETE 09/25/2023 09/25/2023
Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM
MECH COMPLETE 08/02/2023 08/04/2023
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
MECH HOLD 08/01/2023 08/02/2023
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Update mechanical subcontractor
BLD COMPLETE 07/26/2023 07/31/2023
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ENGIN1 COMPLETE 06/08/2023 06/08/2023
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON COMPLETE 06/08/2023 06/08/2023
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
ZON COMPLETE 02/07/2023 02/07/2023
Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM
ENGIN1 COMPLETE 02/07/2023 02/09/2023
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
SW1 COMPLETE 02/07/2023 02/13/2023
Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM
ZON HOLD 02/01/2023 02/02/2023
Note: Held By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM Please make both driveways the same. The right side of the duplex drive way does not show the 16 ft from the same point. Please extend to the sidewalk As per our Supervisor Tracey Doak.
ENGIN1 COMPLETE 02/01/2023 02/02/2023
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
SW1 COMPLETE 02/01/2023 02/07/2023
Note: Released By: EDWARD MADISON - - EMADISON@PALMCOASTGOV.COM
ELEC COMPLETE 01/26/2023 01/26/2023
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
MECH COMPLETE 01/26/2023 01/26/2023
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
BLD COMPLETE 01/26/2023 01/27/2023
Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM
SW1 COMPLETE 01/26/2023 02/01/2023
Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM
ENGIN1 COMPLETE 01/26/2023 01/26/2023
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON HOLD 01/26/2023 01/26/2023
Note: Held By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM Garages must have a driveway extending for a minimum of 20 feet in front of each garage door. The driveway shall be at least the width of the garage door(s), with a minimum width of ten feet, to allow for safe access. For the 20 feet of the driveway that is closest to the garage, driveways for one and two-car garages shall have a minimum width of 16 feet, and driveways for three-car or larger garages shall have a minimum width of 24 feet.
BLD HOLD 01/18/2023 01/24/2023
Note: Held By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM All comments below per the 2020 Florida Building Code PLAN REVIEW COMMENTS: 1. Provide Product Approval for rear glass siding doors. Product Approval submitted is for a swing door and Floor Plans show a slider. Per F.S. 471.025 and F.A.C. 61 G15-23.005.
CUSVC COMPLETE 01/18/2023 01/19/2023
Note: Released By: LISA ASBILL - - lasbill@palmcoastgov.com
ELEC HOLD 01/18/2023 01/18/2023
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM Need correct outlet spacing in master bedroom
ENGIN1 COMPLETE 01/18/2023 01/18/2023
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
LOCATE COMPLETE 01/18/2023 01/24/2023
Note: Released By: TONI CHURCHILL - -
MECH HOLD 01/18/2023 01/18/2023
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Upload Energy calc for side B
SW1 HOLD 01/18/2023 01/25/2023
Note: Held By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM NEED TO MAKE DRAINAGE A SPLIT DRAIN CANT FLOW ALL WATER TO THE BACK NEED TO HAVE THE WIDTH OF THE DRIVEWAY AT THE RIGHT OF WAY LINE
ZON HOLD 01/18/2023 01/18/2023
Note: Held By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM . Site plan: Garages must have a driveway extending for a minimum of 20 feet in front of each garage door. The driveway shall be at least the width of the garage door(s), with a minimum width of ten feet, to allow for safe access. For the 20 feet of the driveway that is closest to the garage, driveways for one and two-car garages shall have a minimum width of 16 feet, and driveways for three-car or larger garages shall have a minimum width of 24 feet Driveway may not be in the 7.5 'or 5' easement. Landscape plan does not match the site plan. Please make sure the rear patio matches also. All plans must match.
SWALE COMPLETE 01/18/2023 04/26/2023
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
CONTRACTOR CHANGE ¤20.00 01/03/2024
REINSPECTION RESIDENTIAL ¤40.00 01/03/2024
REINSPECTION RESIDENTIAL ¤40.00 01/03/2024
REINSPECTION RESIDENTIAL ¤40.00 01/03/2024
SW ENG REINSPECTION 30 ¤30.00 01/03/2024
SW ENG - REVIEW 20 ¤20.00 02/16/2023
SW ENG RES REVIEW 200 ¤200.00 02/16/2023
TRANS IMPACT FEE ADMIN ¤84.36 02/16/2023
TRANS IMPACT FEE ADMIN (¤84.36) 02/16/2023
SEWER INSPECTION ¤25.00 02/16/2023
SEWER CAPITAL FACILITY ¤10,689.64 02/16/2023
WATER CAPITAL FACILITY FEE ¤7,847.76 02/16/2023
SITE PLAN 30 ¤30.00 02/16/2023
CONNECTION FEES ¤2,332.52 02/16/2023
WATER- TURN ON ¤50.00 02/16/2023
ADJUSTMENT 50% (¤632.75) 02/16/2023
ADMINISTRATIVE RESIDENTIAL ¤30.00 02/16/2023
INSPECTION - RESIDENTIAL ¤962.50 02/16/2023
PLAN REVIEW - RESIDENTIAL ¤273.00 02/16/2023
FIRE IMPACT FEE ADMIN ¤25.23 02/16/2023
FIRE IMPACT FEE ADMIN (¤25.23) 02/16/2023
FC IMPACT FEE EMS ¤124.00 02/16/2023
IMPACT FEE FIRE ¤841.04 02/16/2023
FC IMPACT FEE LAW ENFORCEMENT ¤436.00 02/16/2023
FC IMPACT FEE LIBRARY ¤536.00 02/16/2023
IMPACT FEE PARKS ¤3,538.30 02/16/2023
IMPACT FEE SCHOOL ¤10,900.00 02/16/2023
IMPACT FEE TRANSPORTATION ¤2,812.00 02/16/2023
WATER -IRRIGATION INSPECTION ¤50.00 02/16/2023
PARKS IMPACT FEE ADMIN ¤106.15 02/16/2023
PARKS IMPACT FEE ADMIN (¤106.15) 02/16/2023
SURCHARGE FS 533.721 ¤4.00 02/16/2023
SURCHARGE - FS 468.631 ¤6.00 02/16/2023
SW ENG - FOUNDATION SURVEY ¤20.00 02/16/2023
SW ENG INSPECTION 80 ¤80.00 02/16/2023
SW ENG PRE APRON ¤30.00 02/16/2023
Fees Total Due: ¤0.00 Total Paid: ¤41,375.01