I want to search for...
Permit #2023011017
Permit Details
Status: COED
| Parcel Id: 07-11-31-7023-00210-0190 |
| Total Square Footage: 2413 sqft |
| Block: 00210 |
| Subdivision: 2191 - SECTION 23-WYNNFIELD |
| Job Phone: 774-696-6541 |
| Location Address: 7 WHITTLE PL |
| Type: BIA - BUILDING INTERIOR EXTERIOR ALTERATION |
| Issue Date: 02/06/2023 |
| NOC: RECORDED |
| Applicant name: JOHN DESMOND |
| Owner: JONES ELIZABETH A & JON C JONES JTWROS/H&W |
|
Address 7 WHITTLE PLACE PALM COAST, FL 32164 |
| Lot: 0190 |
| Contracted Stated Job Value: ¤275,000.00 |
| Job Description: Major repairs to existing home that burned |
| Type: CN |
Contractor
COMPLETE BUILDERS LLC
| Status | Location Address | State License Number | Phone |
| INACTIVE |
15 CHERRYTREE CT PALM COAST, FL 32137 |
CGC1530956 (Exp: 08/31/2026) | 774-696-6541 |
Sub Contractors
JONATHAN M PEARSON
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
209 N FORSYTH ST BUNNELL, FL 32110 |
CFC1425941 (Exp: 08/31/2026) | 386-597-0944 | 386-437-4996 |
JEFFREY ADAM MCGREGOR
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
1312 YORKTOWN STREET DELAND , FL 32724 |
EC13005662 (Exp: 08/31/2026) | 386-736-7475 | 386-785-1503 |
GARY LLOYD SHEFFIELD
| Status | Location Address | State License Number | Phone |
| ACTIVE |
48 EAGLE LAKES DRIVE FLAGLER BEACH, FL 32136 |
CAC048127 (Exp: 08/31/2026) | 386-597-3280 |
FRANK E SEVERINO
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
1360 N NOVA RD DAYTONA BEACH, FL 32117 |
CBC060543 (Exp: 08/31/2026) | 386-253-1943 | 386-238-0139 |
Inspection History
| Type | Request Date | Result | Inspector |
| BLD - BUILDING FINAL | 12/01/2023 | FINAL APPROVED | MKRASKI |
| Note: 11/29/2023 - PREVIOUS INSPECTION NOTES 1. Disconnect for ODU can not be behind unit 2. Dishwasher plug needs to be wired 3. E-cals do not match equipment installed 4. Garage door buck anchors have been removed for install off door track and needs to be re-installed 5. Condensation line must be a min of 12'' off home 6. ODU requires 4 tie downs | |||
| BLD - BUILDING FINAL | 11/29/2023 | Disapproved - NO FEE | MKRASKI |
| Note: 1. Disconnect for ODU can not be behind unit 2. Dishwasher plug needs to be wired 3. E-cals do not match equipment installed 4. Garage door buck anchors have been removed for install off door track and needs to be re-installed 5. Condensation line must be a min of 12'' off home 6. ODU requires 4 tie downs | |||
| ROW - FINAL INSPECTION | 11/14/2023 | APPROVED | PFLANAGAN |
| Note: At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved. ----------------------------------------------------------------------------------------- 10/9/2023 - PREVIOUS INSPECTION NOTES 1) NEED TO HAVE SOD DOWN ON ALL BARE AREAS ALONG DRIVEWAY 2) NEED TO HAVER THE DUMPSTER REMOVED BEFORE THIS INSPECTION 3) NEED TO HAVE PORTER JOHN REMOVED OR IN THE DRIVEWAY NOTE ALL NEW SOD IN THE RIGHT OF WAY NEEDS TO MTACH EXISTING GRADE SURROUNDING IT ---------------------------------------------------------------------------------------------------------- rjg. See note on Form Board Inspection dated 9/18/23. No culvert installed. | |||
| ELECTRIC - EARLY POWER | 10/16/2023 | APPROVED | RMARTIN |
| ELECTRIC FINAL | 10/16/2023 | CANCELLED BY INSPECTOR | RMARTIN |
| Note: not needed, added the early power | |||
| ROW - FINAL INSPECTION | 10/09/2023 | Disapproved -FEE REQUIRED | PFLANAGAN |
| Note: 1) NEED TO HAVE SOD DOWN ON ALL BARE AREAS ALONG DRIVEWAY 2) NEED TO HAVER THE DUMPSTER REMOVED BEFORE THIS INSPECTION 3) NEED TO HAVE PORTER JOHN REMOVED OR IN THE DRIVEWAY NOTE ALL NEW SOD IN THE RIGHT OF WAY NEEDS TO MTACH EXISTING GRADE SURROUNDING IT ---------------------------------------------------------------------------------------------------------- rjg. See note on Form Board Inspection dated 9/18/23. No culvert installed. | |||
| FORM BOARD | 09/18/2023 | APPROVED - AS NOTED | RGROSS |
| Note: Builder did not have the option of a Pre-pour and used this inspection for it. The only inspection on the type of permit issued. See applicant notes. Apparenlty Tim and Jeff determined that this driveway did not need a culvert. It is the high point. There may not be a swale plan. No pipe installed. | |||
| INSULATION | 08/02/2023 | APPROVED | MKRASKI |
| ALL ROUGH | 08/01/2023 | APPROVED | MKRASKI |
| Note: 7/27/2023 - PREVIOUS INSPECTION NOTES 7/27/23: Previously listed items 3 & 5 remain unresolved. #3 Covered porch also has metal boxes that require bonding at all rough. #5 Outlets are not installed at locations shown on plan detal as indicated. 7/18/2023 - PREVIOUS INSPECTION NOTES 7/18/23 1. Boxes are required for garage lighting 2. Duct layout still does not match what is installed 3. Wiring outside on porch, if using a matalic box for devices bond needs to be made at all rough 4. Master bedroom exhaust duct can not be seen because of insulation 5. Per plans island power should be on each end of island, marked on print 6. Insulation shall not be installed untill after all rough inspection has been passed 7/10/2023 - PREVIOUS INSPECTION NOTES 7/10/23 1. Duct layout does not match what was installed, fix or have revision sunmitted to the Building Dept. 2. All electrical metalic boxes needs to be cleaned out so the bond screw is visible and that its bonded to ground 3. Exhast fan duct is pinched in master bathroom 4. Spare bathroom exhaust fan is hanging by romex 5. Romes needs to be put in boxes outside and in kicten island knee wall 6. Slab is required to be sealed @ spare tub 7. Failed 5' head pressure test 7/5/2023 - PREVIOUS INSPECTION NOTES 1. All exterior door must have a switched light outside of door 2. Boxes missing for front garage lights 3. Fixed windows do not match product approval number, put revision in for windows installed Stopped inspection | |||
| ALL ROUGH | 07/27/2023 | Disapproved -FEE REQUIRED | RSIMS |
| Note: 7/27/23: Previously listed items 3 & 5 remain unresolved. #3 Covered porch also has metal boxes that require bonding at all rough. #5 Outlets are not installed at locations shown on plan detal as indicated. 7/18/2023 - PREVIOUS INSPECTION NOTES 7/18/23 1. Boxes are required for garage lighting 2. Duct layout still does not match what is installed 3. Wiring outside on porch, if using a matalic box for devices bond needs to be made at all rough 4. Master bedroom exhaust duct can not be seen because of insulation 5. Per plans island power should be on each end of island, marked on print 6. Insulation shall not be installed untill after all rough inspection has been passed 7/10/2023 - PREVIOUS INSPECTION NOTES 7/10/23 1. Duct layout does not match what was installed, fix or have revision sunmitted to the Building Dept. 2. All electrical metalic boxes needs to be cleaned out so the bond screw is visible and that its bonded to ground 3. Exhast fan duct is pinched in master bathroom 4. Spare bathroom exhaust fan is hanging by romex 5. Romes needs to be put in boxes outside and in kicten island knee wall 6. Slab is required to be sealed @ spare tub 7. Failed 5' head pressure test 7/5/2023 - PREVIOUS INSPECTION NOTES 1. All exterior door must have a switched light outside of door 2. Boxes missing for front garage lights 3. Fixed windows do not match product approval number, put revision in for windows installed Stopped inspection | |||
| ALL ROUGH | 07/18/2023 | Disapproved -FEE REQUIRED | MKRASKI |
| Note: 7/18/23 1. Boxes are required for garage lighting 2. Duct layout still does not match what is installed 3. Wiring outside on porch, if using a matalic box for devices bond needs to be made at all rough 4. Master bedroom exhaust duct can not be seen because of insulation 5. Per plans island power should be on each end of island, marked on print 6. Insulation shall not be installed untill after all rough inspection has been passed 7/10/2023 - PREVIOUS INSPECTION NOTES 7/10/23 1. Duct layout does not match what was installed, fix or have revision sunmitted to the Building Dept. 2. All electrical metalic boxes needs to be cleaned out so the bond screw is visible and that its bonded to ground 3. Exhast fan duct is pinched in master bathroom 4. Spare bathroom exhaust fan is hanging by romex 5. Romes needs to be put in boxes outside and in kicten island knee wall 6. Slab is required to be sealed @ spare tub 7. Failed 5' head pressure test 7/5/2023 - PREVIOUS INSPECTION NOTES 1. All exterior door must have a switched light outside of door 2. Boxes missing for front garage lights 3. Fixed windows do not match product approval number, put revision in for windows installed Stopped inspection | |||
| ALL ROUGH | 07/10/2023 | Disapproved -FEE REQUIRED | MKRASKI |
| Note: 7/10/23 1. Duct layout does not match what was installed, fix or have revision sunmitted to the Building Dept. 2. All electrical metalic boxes needs to be cleaned out so the bond screw is visible and that its bonded to ground 3. Exhast fan duct is pinched in master bathroom 4. Spare bathroom exhaust fan is hanging by romex 5. Romes needs to be put in boxes outside and in kicten island knee wall 6. Slab is required to be sealed @ spare tub 7. Failed 5' head pressure test 8. Address not visible from road 7/5/2023 - PREVIOUS INSPECTION NOTES 1. All exterior door must have a switched light outside of door 2. Boxes missing for front garage lights 3. Fixed windows do not match product approval number, put revision in for windows installed Stopped inspection | |||
| ALL ROUGH | 07/05/2023 | Disapproved - NO FEE | MKRASKI |
| Note: 1. All exterior door must have a switched light outside of door 2. Boxes missing for front garage lights 3. Fixed windows do not match product approval number, put revision in for windows installed Stopped inspection | |||
| LATH/BRICK/ WATER BARRIER | 06/27/2023 | APPROVED | MKRASKI |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 06/27/2023 | APPROVED | MKRASKI |
| ROOF VALLEY & METAL | 05/03/2023 | APPROVED | MKRASKI |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 05/01/2023 | Disapproved -FEE REQUIRED | MKRASKI |
| Note: 1. Can not see tapcons for twist straps 2. No load bearing detail for attachment to CMU 3. No load bearing door opening detail 4. Missing 4x4 in load bearing wall in master bathroom 5. Stud in load bearing wall in master bathroom has been notched and needs a additional stud Stopped inspection did not look at truss engineering | |||
| ROOF SHEATHING | 04/28/2023 | APPROVED | MKRASKI |
| ROOF VALLEY & METAL | 04/28/2023 | Disapproved -FEE REQUIRED | MKRASKI |
| Note: Missing multiple simplex nails over entire roof | |||
| FOOTER | 04/06/2023 | APPROVED | MKRASKI |
| TIE BEAM / LINTEL | 02/27/2023 | APPROVED | MKRASKI |
| TIE BEAM / LINTEL | 02/22/2023 | Disapproved - NO FEE | MKRASKI |
| Note: Lintal L17 @ front entry missing per plans, need revision submitted to City before inspection can be passed |
Review History
| Department | Status | Date In | Date Out |
| BADMIN | INFORMATION | 02/16/2024 | 02/16/2024 |
| Note: Marked INFORMATION By: MICHELLE RAMOS - (386)986-3780 - MRAMOS@PALMCOASTGOV.COM Termite document is not a full page and missing address. | |||
| BADMIN | INFORMATION | 12/22/2023 | 12/22/2023 |
| Note: Marked INFORMATION By: MICHELLE RAMOS - (386)986-3780 - MRAMOS@PALMCOASTGOV.COM Missing Termite and Blower Door. | |||
| BADMIN | INFORMATION | 12/22/2023 | 12/22/2023 |
| Note: Marked INFORMATION By: MICHELLE RAMOS - (386)986-3780 - MRAMOS@PALMCOASTGOV.COM Termite certificate needed. | |||
| MECH | COMPLETE | 11/29/2023 | 11/29/2023 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| SWALE | COMPLETE | 08/31/2023 | 08/31/2023 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM No culvert pipe required | |||
| ENGIN1 | COMPLETE | 08/14/2023 | 08/18/2023 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 08/14/2023 | 08/17/2023 |
| Note: Released By: ROBERT GROSS - (386)986-4769 - RGROSS@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 08/14/2023 | 08/14/2023 |
| Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 07/27/2023 | 07/27/2023 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 07/12/2023 | 07/13/2023 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 07/07/2023 | 07/11/2023 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| BADMIN | INFORMATION | 05/23/2023 | 05/23/2023 |
| Note: Marked INFORMATION By: BARBIE BEMBRY - (386)986-3780 - BUILDINGDIVISION@PALMCOASTGOV.COM For any future submittals, please be sure to name your files correctly (the plan sheet name should be at the beginning of the name, you can add any additional names, info after the sheet name) example - A.5 7 Whittle Place - not - 7 Whittle Place A.5 | |||
| BLD | COMPLETE | 05/23/2023 | 05/26/2023 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 04/27/2023 | 05/02/2023 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 04/16/2023 | 04/17/2023 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 04/16/2023 | 04/20/2023 |
| Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 04/16/2023 | 04/17/2023 |
| Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 04/04/2023 | 04/10/2023 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 04/04/2023 | 04/12/2023 |
| Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM | |||
| ZON | HOLD | 04/04/2023 | 04/04/2023 |
| Note: Held By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM Please provide the width of the driveway being proposed and the walk way along with material | |||
| BADMIN | INFORMATION | 03/13/2023 | 03/13/2023 |
| Note: Marked INFORMATION By: LIBBY MUSGROVE - - LMUSGROVE@PALMCOASTGOV.COM Document type does not match the files uploaded. Choose plans. | |||
| BLD | COMPLETE | 03/13/2023 | 03/20/2023 |
| Note: Released By: PATRICK BUCKLEY - (386)986-3786 - PBUCKLEY@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 02/23/2023 | 02/24/2023 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 02/01/2023 | 02/02/2023 |
| Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 02/01/2023 | 02/01/2023 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| ELEC | COMPLETE | 02/01/2023 | 02/01/2023 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 02/01/2023 | 02/01/2023 |
| Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM | |||
| BLD | HOLD | 01/23/2023 | 01/24/2023 |
| Note: Held By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM All comments below per the 2020 Florida Building Code PLAN REVIEW COMMENTS: 1. Architect of record is to certify the existing footers and remaining portions of the home are structurally stable. | |||
| ELEC | HOLD | 01/23/2023 | 01/23/2023 |
| Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Need correct outlet spacing in master bedroom and bed 2. NEC 2017 210.52 2. Electric load calcs need to be done to the living space. NEC 2017 220.80 3. Need combo alarm outside of master bedroom. FRC 2020 314 & 315 4. Light and switch by exerior garage door. NEC 2017 210.70 5. Need outlet on the back of the house NEC 2017 210.52 (E) 6. DW outlet can not be behind thre DW NEC 2017 422.16 7. Need outlet by A/C unit NEC 2017 210.63 | |||
| MECH | HOLD | 01/23/2023 | 01/23/2023 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Energy Calcs need to be signed by the builder per 107.1 FBC Residential 2020 7th edition | |||
| PLUM | COMPLETE | 01/23/2023 | 01/24/2023 |
| Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM | |||
| ZON | HOLD | 01/23/2023 | 01/23/2023 |
| Note: Held By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM Elevation pllan: Please add banding to all doors and windows facing the ROW. |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| PLAN REVIEW - REVISION | ¤32.50 | 11/30/2023 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 11/28/2023 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 11/28/2023 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 11/28/2023 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 11/28/2023 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 11/28/2023 |
| PLAN REVIEW - REVISION | ¤32.40 | 11/28/2023 |
| PLAN REVIEW - REVISION | ¤32.50 | 11/28/2023 |
| SW ENG REINSPECTION 20 | ¤20.00 | 11/28/2023 |
| SITE PLAN 30 | ¤30.00 | 02/06/2023 |
| ADJUSTMENT 50% | (¤500.38) | 02/06/2023 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 02/06/2023 |
| INSPECTION - RESIDENTIAL | ¤756.25 | 02/06/2023 |
| PLAN REVIEW - RESIDENTIAL | ¤214.50 | 02/06/2023 |
| SURCHARGE FS 533.721 | ¤3.24 | 02/06/2023 |
| SURCHARGE - FS 468.631 | ¤4.86 | 02/06/2023 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤855.87 |