Permit #2023011017

Permit Details

Status: COED

Parcel Id: 07-11-31-7023-00210-0190
Total Square Footage: 2413 sqft
Block: 00210
Subdivision: 2191 - SECTION 23-WYNNFIELD
Job Phone: 774-696-6541
Location Address: 7 WHITTLE PL
Type: BIA - BUILDING INTERIOR EXTERIOR ALTERATION
Issue Date: 02/06/2023
NOC: RECORDED
Applicant name: JOHN DESMOND
Owner: JONES ELIZABETH A & JON C JONES JTWROS/H&W

Address

7 WHITTLE PLACE

PALM COAST, FL 32164

Lot: 0190
Contracted Stated Job Value: ¤275,000.00
Job Description: Major repairs to existing home that burned
Type: CN

Contractor

COMPLETE BUILDERS LLC
Status Location Address State License Number Phone
INACTIVE

15 CHERRYTREE CT

PALM COAST, FL 32137

CGC1530956 (Exp: 08/31/2026) 774-696-6541

Sub Contractors

JONATHAN M PEARSON
Status Location Address State License Number Phone Fax
ACTIVE

209 N FORSYTH ST

BUNNELL, FL 32110

CFC1425941 (Exp: 08/31/2026) 386-597-0944 386-437-4996
JEFFREY ADAM MCGREGOR
Status Location Address State License Number Phone Fax
ACTIVE

1312 YORKTOWN STREET

DELAND , FL 32724

EC13005662 (Exp: 08/31/2026) 386-736-7475 386-785-1503
GARY LLOYD SHEFFIELD
Status Location Address State License Number Phone
ACTIVE

48 EAGLE LAKES DRIVE

FLAGLER BEACH, FL 32136

CAC048127 (Exp: 08/31/2026) 386-597-3280
FRANK E SEVERINO
Status Location Address State License Number Phone Fax
ACTIVE

1360 N NOVA RD

DAYTONA BEACH, FL 32117

CBC060543 (Exp: 08/31/2026) 386-253-1943 386-238-0139

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 12/01/2023 FINAL APPROVED MKRASKI
Note: 11/29/2023 - PREVIOUS INSPECTION NOTES 1. Disconnect for ODU can not be behind unit 2. Dishwasher plug needs to be wired 3. E-cals do not match equipment installed 4. Garage door buck anchors have been removed for install off door track and needs to be re-installed 5. Condensation line must be a min of 12'' off home 6. ODU requires 4 tie downs
BLD - BUILDING FINAL 11/29/2023 Disapproved - NO FEE MKRASKI
Note: 1. Disconnect for ODU can not be behind unit 2. Dishwasher plug needs to be wired 3. E-cals do not match equipment installed 4. Garage door buck anchors have been removed for install off door track and needs to be re-installed 5. Condensation line must be a min of 12'' off home 6. ODU requires 4 tie downs
ROW - FINAL INSPECTION 11/14/2023 APPROVED PFLANAGAN
Note: At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved. ----------------------------------------------------------------------------------------- 10/9/2023 - PREVIOUS INSPECTION NOTES 1) NEED TO HAVE SOD DOWN ON ALL BARE AREAS ALONG DRIVEWAY 2) NEED TO HAVER THE DUMPSTER REMOVED BEFORE THIS INSPECTION 3) NEED TO HAVE PORTER JOHN REMOVED OR IN THE DRIVEWAY NOTE ALL NEW SOD IN THE RIGHT OF WAY NEEDS TO MTACH EXISTING GRADE SURROUNDING IT ---------------------------------------------------------------------------------------------------------- rjg. See note on Form Board Inspection dated 9/18/23. No culvert installed.
ELECTRIC - EARLY POWER 10/16/2023 APPROVED RMARTIN
ELECTRIC FINAL 10/16/2023 CANCELLED BY INSPECTOR RMARTIN
Note: not needed, added the early power
ROW - FINAL INSPECTION 10/09/2023 Disapproved -FEE REQUIRED PFLANAGAN
Note: 1) NEED TO HAVE SOD DOWN ON ALL BARE AREAS ALONG DRIVEWAY 2) NEED TO HAVER THE DUMPSTER REMOVED BEFORE THIS INSPECTION 3) NEED TO HAVE PORTER JOHN REMOVED OR IN THE DRIVEWAY NOTE ALL NEW SOD IN THE RIGHT OF WAY NEEDS TO MTACH EXISTING GRADE SURROUNDING IT ---------------------------------------------------------------------------------------------------------- rjg. See note on Form Board Inspection dated 9/18/23. No culvert installed.
FORM BOARD 09/18/2023 APPROVED - AS NOTED RGROSS
Note: Builder did not have the option of a Pre-pour and used this inspection for it. The only inspection on the type of permit issued. See applicant notes. Apparenlty Tim and Jeff determined that this driveway did not need a culvert. It is the high point. There may not be a swale plan. No pipe installed.
INSULATION 08/02/2023 APPROVED MKRASKI
ALL ROUGH 08/01/2023 APPROVED MKRASKI
Note: 7/27/2023 - PREVIOUS INSPECTION NOTES 7/27/23: Previously listed items 3 & 5 remain unresolved. #3 Covered porch also has metal boxes that require bonding at all rough. #5 Outlets are not installed at locations shown on plan detal as indicated. 7/18/2023 - PREVIOUS INSPECTION NOTES 7/18/23 1. Boxes are required for garage lighting 2. Duct layout still does not match what is installed 3. Wiring outside on porch, if using a matalic box for devices bond needs to be made at all rough 4. Master bedroom exhaust duct can not be seen because of insulation 5. Per plans island power should be on each end of island, marked on print 6. Insulation shall not be installed untill after all rough inspection has been passed 7/10/2023 - PREVIOUS INSPECTION NOTES 7/10/23 1. Duct layout does not match what was installed, fix or have revision sunmitted to the Building Dept. 2. All electrical metalic boxes needs to be cleaned out so the bond screw is visible and that its bonded to ground 3. Exhast fan duct is pinched in master bathroom 4. Spare bathroom exhaust fan is hanging by romex 5. Romes needs to be put in boxes outside and in kicten island knee wall 6. Slab is required to be sealed @ spare tub 7. Failed 5' head pressure test 7/5/2023 - PREVIOUS INSPECTION NOTES 1. All exterior door must have a switched light outside of door 2. Boxes missing for front garage lights 3. Fixed windows do not match product approval number, put revision in for windows installed Stopped inspection
ALL ROUGH 07/27/2023 Disapproved -FEE REQUIRED RSIMS
Note: 7/27/23: Previously listed items 3 & 5 remain unresolved. #3 Covered porch also has metal boxes that require bonding at all rough. #5 Outlets are not installed at locations shown on plan detal as indicated. 7/18/2023 - PREVIOUS INSPECTION NOTES 7/18/23 1. Boxes are required for garage lighting 2. Duct layout still does not match what is installed 3. Wiring outside on porch, if using a matalic box for devices bond needs to be made at all rough 4. Master bedroom exhaust duct can not be seen because of insulation 5. Per plans island power should be on each end of island, marked on print 6. Insulation shall not be installed untill after all rough inspection has been passed 7/10/2023 - PREVIOUS INSPECTION NOTES 7/10/23 1. Duct layout does not match what was installed, fix or have revision sunmitted to the Building Dept. 2. All electrical metalic boxes needs to be cleaned out so the bond screw is visible and that its bonded to ground 3. Exhast fan duct is pinched in master bathroom 4. Spare bathroom exhaust fan is hanging by romex 5. Romes needs to be put in boxes outside and in kicten island knee wall 6. Slab is required to be sealed @ spare tub 7. Failed 5' head pressure test 7/5/2023 - PREVIOUS INSPECTION NOTES 1. All exterior door must have a switched light outside of door 2. Boxes missing for front garage lights 3. Fixed windows do not match product approval number, put revision in for windows installed Stopped inspection
ALL ROUGH 07/18/2023 Disapproved -FEE REQUIRED MKRASKI
Note: 7/18/23 1. Boxes are required for garage lighting 2. Duct layout still does not match what is installed 3. Wiring outside on porch, if using a matalic box for devices bond needs to be made at all rough 4. Master bedroom exhaust duct can not be seen because of insulation 5. Per plans island power should be on each end of island, marked on print 6. Insulation shall not be installed untill after all rough inspection has been passed 7/10/2023 - PREVIOUS INSPECTION NOTES 7/10/23 1. Duct layout does not match what was installed, fix or have revision sunmitted to the Building Dept. 2. All electrical metalic boxes needs to be cleaned out so the bond screw is visible and that its bonded to ground 3. Exhast fan duct is pinched in master bathroom 4. Spare bathroom exhaust fan is hanging by romex 5. Romes needs to be put in boxes outside and in kicten island knee wall 6. Slab is required to be sealed @ spare tub 7. Failed 5' head pressure test 7/5/2023 - PREVIOUS INSPECTION NOTES 1. All exterior door must have a switched light outside of door 2. Boxes missing for front garage lights 3. Fixed windows do not match product approval number, put revision in for windows installed Stopped inspection
ALL ROUGH 07/10/2023 Disapproved -FEE REQUIRED MKRASKI
Note: 7/10/23 1. Duct layout does not match what was installed, fix or have revision sunmitted to the Building Dept. 2. All electrical metalic boxes needs to be cleaned out so the bond screw is visible and that its bonded to ground 3. Exhast fan duct is pinched in master bathroom 4. Spare bathroom exhaust fan is hanging by romex 5. Romes needs to be put in boxes outside and in kicten island knee wall 6. Slab is required to be sealed @ spare tub 7. Failed 5' head pressure test 8. Address not visible from road 7/5/2023 - PREVIOUS INSPECTION NOTES 1. All exterior door must have a switched light outside of door 2. Boxes missing for front garage lights 3. Fixed windows do not match product approval number, put revision in for windows installed Stopped inspection
ALL ROUGH 07/05/2023 Disapproved - NO FEE MKRASKI
Note: 1. All exterior door must have a switched light outside of door 2. Boxes missing for front garage lights 3. Fixed windows do not match product approval number, put revision in for windows installed Stopped inspection
LATH/BRICK/ WATER BARRIER 06/27/2023 APPROVED MKRASKI
ROOF SHEATHING / BRACES/TIES/DOWN CELL 06/27/2023 APPROVED MKRASKI
ROOF VALLEY & METAL 05/03/2023 APPROVED MKRASKI
ROOF SHEATHING / BRACES/TIES/DOWN CELL 05/01/2023 Disapproved -FEE REQUIRED MKRASKI
Note: 1. Can not see tapcons for twist straps 2. No load bearing detail for attachment to CMU 3. No load bearing door opening detail 4. Missing 4x4 in load bearing wall in master bathroom 5. Stud in load bearing wall in master bathroom has been notched and needs a additional stud Stopped inspection did not look at truss engineering
ROOF SHEATHING 04/28/2023 APPROVED MKRASKI
ROOF VALLEY & METAL 04/28/2023 Disapproved -FEE REQUIRED MKRASKI
Note: Missing multiple simplex nails over entire roof
FOOTER 04/06/2023 APPROVED MKRASKI
TIE BEAM / LINTEL 02/27/2023 APPROVED MKRASKI
TIE BEAM / LINTEL 02/22/2023 Disapproved - NO FEE MKRASKI
Note: Lintal L17 @ front entry missing per plans, need revision submitted to City before inspection can be passed

Review History

Department Status Date In Date Out
BADMIN INFORMATION 02/16/2024 02/16/2024
Note: Marked INFORMATION By: MICHELLE RAMOS - (386)986-3780 - MRAMOS@PALMCOASTGOV.COM Termite document is not a full page and missing address.
BADMIN INFORMATION 12/22/2023 12/22/2023
Note: Marked INFORMATION By: MICHELLE RAMOS - (386)986-3780 - MRAMOS@PALMCOASTGOV.COM Missing Termite and Blower Door.
BADMIN INFORMATION 12/22/2023 12/22/2023
Note: Marked INFORMATION By: MICHELLE RAMOS - (386)986-3780 - MRAMOS@PALMCOASTGOV.COM Termite certificate needed.
MECH COMPLETE 11/29/2023 11/29/2023
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
SWALE COMPLETE 08/31/2023 08/31/2023
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM No culvert pipe required
ENGIN1 COMPLETE 08/14/2023 08/18/2023
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
SW1 COMPLETE 08/14/2023 08/17/2023
Note: Released By: ROBERT GROSS - (386)986-4769 - RGROSS@PALMCOASTGOV.COM
ZON COMPLETE 08/14/2023 08/14/2023
Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM
MECH COMPLETE 07/27/2023 07/27/2023
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
MECH COMPLETE 07/12/2023 07/13/2023
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
BLD COMPLETE 07/07/2023 07/11/2023
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
BADMIN INFORMATION 05/23/2023 05/23/2023
Note: Marked INFORMATION By: BARBIE BEMBRY - (386)986-3780 - BUILDINGDIVISION@PALMCOASTGOV.COM For any future submittals, please be sure to name your files correctly (the plan sheet name should be at the beginning of the name, you can add any additional names, info after the sheet name) example - A.5 7 Whittle Place - not - 7 Whittle Place A.5
BLD COMPLETE 05/23/2023 05/26/2023
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
BLD COMPLETE 04/27/2023 05/02/2023
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ENGIN1 COMPLETE 04/16/2023 04/17/2023
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
SW1 COMPLETE 04/16/2023 04/20/2023
Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM
ZON COMPLETE 04/16/2023 04/17/2023
Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM
ENGIN1 COMPLETE 04/04/2023 04/10/2023
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
SW1 COMPLETE 04/04/2023 04/12/2023
Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM
ZON HOLD 04/04/2023 04/04/2023
Note: Held By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM Please provide the width of the driveway being proposed and the walk way along with material
BADMIN INFORMATION 03/13/2023 03/13/2023
Note: Marked INFORMATION By: LIBBY MUSGROVE - - LMUSGROVE@PALMCOASTGOV.COM Document type does not match the files uploaded. Choose plans.
BLD COMPLETE 03/13/2023 03/20/2023
Note: Released By: PATRICK BUCKLEY - (386)986-3786 - PBUCKLEY@PALMCOASTGOV.COM
BLD COMPLETE 02/23/2023 02/24/2023
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ZON COMPLETE 02/01/2023 02/02/2023
Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM
MECH COMPLETE 02/01/2023 02/01/2023
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
ELEC COMPLETE 02/01/2023 02/01/2023
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
BLD COMPLETE 02/01/2023 02/01/2023
Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM
BLD HOLD 01/23/2023 01/24/2023
Note: Held By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM All comments below per the 2020 Florida Building Code PLAN REVIEW COMMENTS: 1. Architect of record is to certify the existing footers and remaining portions of the home are structurally stable.
ELEC HOLD 01/23/2023 01/23/2023
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Need correct outlet spacing in master bedroom and bed 2. NEC 2017 210.52 2. Electric load calcs need to be done to the living space. NEC 2017 220.80 3. Need combo alarm outside of master bedroom. FRC 2020 314 & 315 4. Light and switch by exerior garage door. NEC 2017 210.70 5. Need outlet on the back of the house NEC 2017 210.52 (E) 6. DW outlet can not be behind thre DW NEC 2017 422.16 7. Need outlet by A/C unit NEC 2017 210.63
MECH HOLD 01/23/2023 01/23/2023
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Energy Calcs need to be signed by the builder per 107.1 FBC Residential 2020 7th edition
PLUM COMPLETE 01/23/2023 01/24/2023
Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM
ZON HOLD 01/23/2023 01/23/2023
Note: Held By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM Elevation pllan: Please add banding to all doors and windows facing the ROW.

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
PLAN REVIEW - REVISION ¤32.50 11/30/2023
REINSPECTION RESIDENTIAL ¤40.00 11/28/2023
REINSPECTION RESIDENTIAL ¤40.00 11/28/2023
REINSPECTION RESIDENTIAL ¤40.00 11/28/2023
REINSPECTION RESIDENTIAL ¤40.00 11/28/2023
REINSPECTION RESIDENTIAL ¤40.00 11/28/2023
PLAN REVIEW - REVISION ¤32.40 11/28/2023
PLAN REVIEW - REVISION ¤32.50 11/28/2023
SW ENG REINSPECTION 20 ¤20.00 11/28/2023
SITE PLAN 30 ¤30.00 02/06/2023
ADJUSTMENT 50% (¤500.38) 02/06/2023
ADMINISTRATIVE RESIDENTIAL ¤30.00 02/06/2023
INSPECTION - RESIDENTIAL ¤756.25 02/06/2023
PLAN REVIEW - RESIDENTIAL ¤214.50 02/06/2023
SURCHARGE FS 533.721 ¤3.24 02/06/2023
SURCHARGE - FS 468.631 ¤4.86 02/06/2023
Fees Total Due: ¤0.00 Total Paid: ¤855.87