I want to search for...

Permit #2023011061

Permit Details

Status: COED

Parcel Id: 07-11-31-7032-00040-0110
CONDITIONED SPACE: 2295 sqft
GARAGE: 538 sqft
OPENED PORCH (WITH ROOF) : 201 sqft
OPENED PORCH (WITH ROOF) : 229 sqft
Total Square Footage: 3263 sqft
Block: 00040
Subdivision: 2155 - SECTION 32-ROYAL PALMS
Job Phone: 912-258-2201
Location Address: 19 ROUND THORN DR
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 02/15/2023
NOC: RECORDED
Applicant name: JAMES FUCETOLA III
Owner: PALM COAST COMMUNITIES LLC

Address

PO BOX 22547

ST SIMONS ISLAND, GA 31522

Lot: 0110
Contracted Stated Job Value: ¤215,000.00
Job Description: Single Family Residence
Type: CN

Contractor

PALM COAST COMMUNITIES LLC
Status Location Address State License Number Phone
INACTIVE

PO BOX 22547

PALM COAST, FL 32164

CBC1262878 (Exp: 08/31/2026) 321-501-4617

Sub Contractors

WILLIAM FRANK DUDLEY JR.
Status Location Address State License Number Phone
ACTIVE

P.O. BOX 978

Bunnell, FL 32110

EC0003177 (Exp: 08/31/2026) (386)437-3068
OLEG BELINSKIY
Status Location Address State License Number Phone
ACTIVE

19 PINE CIRCLE DRIVE19

PALM COAST, FL 32167

CCC1325974 (Exp: 08/31/2026) 386-263-7906
GARY LLOYD SHEFFIELD
Status Location Address State License Number Phone
ACTIVE

48 EAGLE LAKES DRIVE

FLAGLER BEACH, FL 32136

CAC048127 (Exp: 08/31/2026) 386-597-3280
JEFFREY TROY SABAKA
Status Location Address State License Number Phone Fax
ACTIVE

2191 DEERWOOD ACRES DR

ST AUGUSTINE, FL 32084

CFC1427439 (Exp: 08/31/2026) 904-838-2218 904-819-0965

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 09/28/2023 FINAL APPROVED BTAYLOR
U-CROSS CONNECTION 09/15/2023 APPROVED - AS NOTED LFITZGERALD
Note: has potable irrigation with DBL check -no cross connection
ROW - FINAL APRON (AFTER POUR) 09/15/2023 APPROVED FSLADISH
Note: 09/15/23 PIPE IS GOOD. CUTS MADE. CULVERT CLEAR. HOT PATCH COMPLETED. At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved. ________________________________________________________________________________________________________________________ Inspector Notes from Inspection 9465 09/12/23 NEED TO REMOVE THE SHRUB AND BARK MULCH AND PUT DOWN SOD MATCHED TO GRADE INSTEAD ON THE LEFT SIDE AT THE AC UNIT BEFORE ROW FINAL. IT IS NOT ALLOWING THE WATER TO DRAIN PAST IT AS SHOWN IN THE FINAL SURVEY. APPROVING AS NOTED.
ROW - STORMWATER FINAL 09/15/2023 APPROVED FSLADISH
Note: 09/15/23 REQUESTED CORRECTION MADE. LOOKED GOOD AT THE TIME OF THIS INSPECTION. At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved. Inspector Notes from Inspection 9465 09/12/23 NEED TO REMOVE THE SHRUB AND BARK MULCH AND PUT DOWN SOD MATCHED TO GRADE INSTEAD ON THE LEFT SIDE AT THE AC UNIT BEFORE ROW FINAL. IT IS NOT ALLOWING THE WATER TO DRAIN PAST IT AS SHOWN IN THE FINAL SURVEY. APPROVING AS NOTED.
U -UTILITY RESIDENTIAL FINAL 09/15/2023 FINAL APPROVED LFITZGERALD
ROW- FINAL SURVEY/GRADING CERTIFICATION 09/12/2023 APPROVED FSLADISH
ROW FIELD SURVEY /GRADING CERTIFICATION 09/12/2023 APPROVED - AS NOTED FSLADISH
Note: 09/12/23 NEED TO REMOVE THE SHRUB AND BARK MULCH AND PUT DOWN SOD MATCHED TO GRADE INSTEAD ON THE LEFT SIDE AT THE AC UNIT BEFORE ROW FINAL. IT IS NOT ALLOWING THE WATER TO DRAIN PAST IT AS SHOWN IN THE FINAL SURVEY. APPROVING AS NOTED.
ELECTRIC - EARLY POWER 08/28/2023 APPROVED JWALKER
Note: 8/25/2023 - PREVIOUS INSPECTION NOTES
ELECTRIC - EARLY POWER 08/25/2023 CANCELLED BY APPLICANT JWALKER
ROW- PROJECT STATUS 08/22/2023 APPROVED GBERTOLA
Note: I have a meeting scheduled with the grading company at their location. The final survey will not provide the accurate elevation for the empty lot on the left side. There is a 2-foot difference from the empty lot to the bottom of the property line.
ROW- PRE-APRON (PRE-POUR) 08/03/2023 APPROVED FSLADISH
Note: 08/03/23 pipe is good. ready to pour at the time of this inspection. AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS BEFORE POURING. MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL
U - SEWER TIE IN 08/01/2023 APPROVED - AS NOTED MGIBSON
Note: THIS WAS A VIRTUAL INSPECTION
INSULATION 07/19/2023 APPROVED JWALKER
Note: Inspector Notes from Inspection 2420 7/10/23 1. Bearing wall anchors listed below have not been installed please also note the T29 truss is not anchored to the bearing wall. Anchors are shown on each of the bearing wall studs Top and Bottom. There is no detail for the column below the truss T-29 and required anchors on the column. 2. Install nail plated at each of the bathroom drain lines bottom plated and one at the UFB wire kitchen wall bottom plate. Contractor may proceed with insulation. Leave the Bearing wall achors exposed for reinspection. If the SDWC screws used at every other stud and at the T-29 support column please have the engineer submitt a detailed revision to the building department for the anchor change. 6/26/2023 - PREVIOUS INSPECTION NOTES 1. The revision or the engineer fix listed at the tie beam lintel inspection has not been submitted to the building department. 2. Missed engineering at truss TO1 3. Garage bearing wall is missing the SP1 or 4's and 2 or 4's at the top and bottom of the wall. CHECK FOR CORRECTIONS AT THE ALL ROUGH INSPECTION. 6-26-23 1. Garage bearing wall is missing the SP1 or 4's and 2 or 4's at the top and bottom of the wall. 2. Panel box needs to be framed in. Wires can not be on exterior of wall without being covered.
LATH/BRICK/ WATER BARRIER 07/10/2023 APPROVED JWALKER
Note: 6/27/2023 - PREVIOUS INSPECTION NOTES This inspection cannot be passed until the correction listed at the tie beam and lintel inspection has been corrected as allowing the stucco install will cover up the areas of concern. The notes from the tie beam inspection are attached below. (4 ) of the 12" x 12" block columns at the front entry and entire length of the front entry cmu wall are nonbearing on concrete below by appx 2 3/4". Contractor will need to have the engineer submitt a letter signed and sealed letter to the building department stating the colums and the wall are structually sound. Or submitt a revision to the building department showing a fix for the non bearing areas of the CMU. The contractor may contiune with pouring the down cells at own risk that demo may be needed in the areas listed above.
ALL ROUGH 07/10/2023 APPROVED - AS NOTED JWALKER
Note: 7/10/23 1. Bearing wall anchors listed below have not been installed please also note the T29 truss is not anchored to the bearing wall. Anchors are shown on each of the bearing wall studs Top and Bottom. There is no detail for the column below the truss T-29 and required anchors on the column. 2. Install nail plated at each of the bathroom drain lines bottom plated and one at the UFB wire kitchen wall bottom plate. Contractor may proceed with insulation. Leave the Bearing wall achors exposed for reinspection. If the SDWC screws used at every other stud and at the T-29 support column please have the engineer submitt a detailed revision to the building department for the anchor change. 6/26/2023 - PREVIOUS INSPECTION NOTES 1. The revision or the engineer fix listed at the tie beam lintel inspection has not been submitted to the building department. 2. Missed engineering at truss TO1 3. Garage bearing wall is missing the SP1 or 4's and 2 or 4's at the top and bottom of the wall. CHECK FOR CORRECTIONS AT THE ALL ROUGH INSPECTION. 6-26-23 1. Garage bearing wall is missing the SP1 or 4's and 2 or 4's at the top and bottom of the wall. 2. Panel box needs to be framed in. Wires can not be on exterior of wall without being covered.
ROOF SHEATHING / BRACES/TIES/DOWN CELL 06/30/2023 APPROVED - AS NOTED JWALKER
Note: This inspection was previously appoved as noted. Contractor needs to have the engineer submit a revision to the building department concerning the tie beam and lintel inspection.
LATH/BRICK/ WATER BARRIER 06/27/2023 Disapproved - NO FEE JWALKER
Note: This inspection cannot be passed until the correction listed at the tie beam and lintel inspection has been corrected as allowing the stucco install will cover up the areas of concern. The notes from the tie beam inspection are attached below. (4 ) of the 12" x 12" block columns at the front entry and entire length of the front entry cmu wall are nonbearing on concrete below by appx 2 3/4". Contractor will need to have the engineer submitt a letter signed and sealed letter to the building department stating the colums and the wall are structually sound. Or submitt a revision to the building department showing a fix for the non bearing areas of the CMU. The contractor may contiune with pouring the down cells at own risk that demo may be needed in the areas listed above.
ALL ROUGH 06/26/2023 Disapproved -FEE REQUIRED BTAYLOR
Note: 1. The revision or the engineer fix listed at the tie beam lintel inspection has not been submitted to the building department. 2. Missed engineering at truss TO1 3. Garage bearing wall is missing the SP1 or 4's and 2 or 4's at the top and bottom of the wall. CHECK FOR CORRECTIONS AT THE ALL ROUGH INSPECTION. 6-26-23 1. Garage bearing wall is missing the SP1 or 4's and 2 or 4's at the top and bottom of the wall. 2. Panel box needs to be framed in. Wires can not be on exterior of wall without being covered.
ROOF SHEATHING / BRACES/TIES/DOWN CELL 06/06/2023 APPROVED JWALKER
Note: This inspection was done and approved as noted on 5/22/23. Note to the contractor. Listed at the tie beam and lintel inspection. A revision needs to be submitted and approved before the All Rough inspection can be passed. Please submitt ASAP.
ROOF VALLEY & METAL 05/30/2023 APPROVED LMILLER
Note: 5/25/2023 - PREVIOUS INSPECTION NOTES Starter row of synthetic underlayment has not been doubled. Synthetic underlayment is to be fastened 6" o.c. at the laps and ends and 12" o.c. in the field. Drip edge has not be fastened. 4x4 L flashing is to be set in roofing cement.
ROOF VALLEY & METAL 05/25/2023 Disapproved -FEE REQUIRED JWALKER
Note: Starter row of synthetic underlayment has not been doubled. Synthetic underlayment is to be fastened 6" o.c. at the laps and ends and 12" o.c. in the field. Drip edge has not be fastened. 4x4 L flashing is to be set in roofing cement.
WALL SHEATHING 05/23/2023 APPROVED JWALKER
ROOF SHEATHING / BRACES/TIES/DOWN CELL 05/22/2023 APPROVED - AS NOTED JWALKER
Note: 1. The revision or the engineer fix listed at the tie beam lintel inspection has not been submitted to the building department. 2. Missed engineering at truss TO1 3. Garage bearing wall is missing the SP1 or 4's and 2 or 4's at the top and bottom of the wall. CHECK FOR CORRECTIONS AT THE ALL ROUGH INSPECTION.
FOUND SURVEY APPROVED (OFFICE) 05/18/2023 APPROVED TBAKER
TIE BEAM / LINTEL 05/08/2023 APPROVED - AS NOTED JWALKER
Note: 4 12" x 12" block columns at the front entry and entire length of the front entry cmu wall are nonbearing on concrete below by appx 2 3/4". Contractor will need to have the engineer submitt a letter signed and sealed letter to the building department stating the colums and the wall are structually sound. Or submitt a revision to the building department showing a fix for the non bearing areas of the CMU. The contractor may contiune with pouring the down cells at own risk that demo may be needed in the areas listed above.
MONOLITHIC SLAB 04/27/2023 APPROVED JWALKER
Note: 4/26/2023 - PREVIOUS INSPECTION NOTES
MONOLITHIC SLAB 04/26/2023 CANCELLED BY APPLICANT FWILLIS
PLUMBING 1ST ROUGH UNDERGROUND 04/20/2023 APPROVED - AS NOTED MGIBSON
Note: 4/19/2023 - PREVIOUS INSPECTION NOTES Water supply pipe has been covered over nunable to verify proper pipe type and install. STEEL HEAD PLUMBING ONLY INSTALLS SCHEDUAL 40 ASTM STANDARD PIPE FOR WATER MAIN AND INSTALLS BEYOND REQUIRED DEPTH
GRAVITY SEWER TEST 04/19/2023 APPROVED JWALKER
PLUMBING 1ST ROUGH UNDERGROUND 04/19/2023 Disapproved - NO FEE JWALKER
Note: Water supply pipe has been covered over nunable to verify proper pipe type and install.
WATER METER INSTALLATION REQUEST 03/09/2023 APPROVED CSTONE

Review History

Department Status Date In Date Out
BLD COMPLETE 07/13/2023 07/17/2023
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
BLD COMPLETE 07/05/2023 07/07/2023
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
ENGIN1 COMPLETE 05/18/2023 05/18/2023
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON COMPLETE 05/18/2023 05/18/2023
Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM
ENGIN1 COMPLETE 04/05/2023 04/05/2023
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
SW1 COMPLETE 04/05/2023 04/13/2023
Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM
ZON COMPLETE 04/05/2023 04/05/2023
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
ELEC COMPLETE 02/07/2023 02/07/2023
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
SWALE COMPLETE 01/24/2023 05/03/2023
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
BLD COMPLETE 01/23/2023 01/24/2023
Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM
CUSVC COMPLETE 01/23/2023 01/25/2023
Note: Released By: LISA ASBILL - - lasbill@palmcoastgov.com
ELEC HOLD 01/23/2023 01/24/2023
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM Submit manufacture specs on recessed can lights in garage showing the fire rating. FRC 2020 302.5
ENGIN1 COMPLETE 01/23/2023 01/24/2023
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
LOCATE COMPLETE 01/23/2023 01/26/2023
Note: Released By: TONI CHURCHILL - -
MECH COMPLETE 01/23/2023 01/24/2023
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
SW1 COMPLETE 01/23/2023 01/31/2023
Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM
ZON COMPLETE 01/23/2023 01/24/2023
Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
PLAN REVIEW - REVISION ¤32.50 09/28/2023
REINSPECTION RESIDENTIAL ¤40.00 09/28/2023
REINSPECTION RESIDENTIAL ¤40.00 09/28/2023
SW ENG REINSPECTION 20 ¤20.00 09/28/2023
SW ENG - REVIEW 20 ¤20.00 02/15/2023
SW ENG RES REVIEW 200 ¤200.00 02/15/2023
TRANS IMPACT FEE ADMIN ¤54.36 02/15/2023
TRANS IMPACT FEE ADMIN (¤54.36) 02/15/2023
SEWER CREDIT (¤2,465.75) 02/15/2023
SEWER INSPECTION ¤25.00 02/15/2023
SEWER CAPITAL FACILITY ¤5,344.82 02/15/2023
WATER CAPITAL FACILITY FEE ¤3,923.88 02/15/2023
SITE PLAN 30 ¤30.00 02/15/2023
WATER- TURN ON ¤25.00 02/15/2023
ADJUSTMENT 50% (¤533.91) 02/15/2023
ADMINISTRATIVE RESIDENTIAL ¤30.00 02/15/2023
INSPECTION - RESIDENTIAL ¤808.50 02/15/2023
PLAN REVIEW - RESIDENTIAL ¤229.32 02/15/2023
CONNECTION FEES ¤1,166.26 02/15/2023
FIRE IMPACT FEE ADMIN ¤12.62 02/15/2023
FIRE IMPACT FEE ADMIN (¤12.62) 02/15/2023
FC IMPACT FEE EMS ¤62.00 02/15/2023
FC IMPACT FEE EMS ¤62.00 02/15/2023
IMPACT FEE FIRE ¤420.52 02/15/2023
FC IMPACT FEE LAW ENFORCEMENT ¤218.00 02/15/2023
FC IMPACT FEE LAW ENFORCEMENT ¤218.00 02/15/2023
FC IMPACT FEE LIBRARY ¤268.00 02/15/2023
FC IMPACT FEE LIBRARY ¤268.00 02/15/2023
IMPACT FEE PARKS ¤1,769.15 02/15/2023
IMPACT FEE SCHOOL ¤5,450.00 02/15/2023
IMPACT FEE TRANSPORTATION ¤1,812.00 02/15/2023
WATER -IRRIGATION INSPECTION ¤25.00 02/15/2023
PARKS IMPACT FEE ADMIN ¤53.07 02/15/2023
PARKS IMPACT FEE ADMIN (¤53.07) 02/15/2023
SURCHARGE FS 533.721 ¤3.43 02/15/2023
SURCHARGE - FS 468.631 ¤5.15 02/15/2023
SW ENG - FOUNDATION SURVEY ¤20.00 02/15/2023
SW ENG INSPECTION 80 ¤80.00 02/15/2023
SW ENG PRE APRON ¤30.00 02/15/2023
Fees Total Due: ¤0.00 Total Paid: ¤19,646.87