I want to search for...
Permit #2023011439
Permit Details
Status: FINAL
| Parcel Id: 20-12-31-2964-00000-0650 |
| Block: 00000 |
| Subdivision: 2307 - GRAND LANDINGS PHASE 4 |
| Job Phone: 386-212-2958 |
| Location Address: 157 WOOD STORK LN |
| Type: PO - POOL |
| Issue Date: 02/27/2023 |
| NOC: RECORDED |
| Applicant name: COBY KYLE MOORE |
| Owner: BULLOCK ERNESTINE & BRUCE BULLOCK |
|
Address 157 WOOD STORK LN PALM COAST, FL 32164 |
| Lot: 0650 |
| Contracted Stated Job Value: ¤66,000.00 |
| Job Description: Swimming pool with deck- screen by others |
| Type: CN |
Contractor
CM DESIGNS INC.
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
1050 ROBERTS STREET ORMOND BEACH, FL 32174 |
CPC1456991 (Exp: 08/31/2026) | (386)615-7425 | 386-676-2963 |
Sub Contractors
GREGORY ALAN WARD
| Status | Location Address | State License Number | Phone |
| INACTIVE |
P.O. BOX 731453 ORMOND BEACH, FL 32174 |
EC13005000 (Exp: 08/31/2026) | 386-566-7248 |
Inspection History
| Type | Request Date | Result | Inspector |
| POOL FINAL | 12/15/2023 | FINAL APPROVED | BTAYLOR |
| Note: 12/12/2023 - PREVIOUS INSPECTION NOTES 12/12/23: As previously noted during Inspection 2620, the Pool Heater requires 4 FPA anchors (FBC-M1307.2). Inspector Notes from Inspection 2610 5/9/23: I had to secure the safety fence for you. Please make sure it stays in place (as required) while not working. 5/5/2023 - PREVIOUS INSPECTION NOTES 5/5/23: 1). Footer does not consistently follow any of the approved footers on the Master Pool plan. 2). Clearance to rebar is not met in multiple places. (R404.1.2.3.7.4) 3). Safety fence is down & not installed properly. Safety fence must remain in tact during all times that the pool is not being actively worked on with personnel on-site. | |||
| POOL FINAL | 12/12/2023 | Disapproved -FEE REQUIRED | RSIMS |
| Note: 12/12/23: As previously noted during Inspection 2620, the Pool Heater requires 4 FPA anchors (FBC-M1307.2). Inspector Notes from Inspection 2610 5/9/23: I had to secure the safety fence for you. Please make sure it stays in place (as required) while not working. 5/5/2023 - PREVIOUS INSPECTION NOTES 5/5/23: 1). Footer does not consistently follow any of the approved footers on the Master Pool plan. 2). Clearance to rebar is not met in multiple places. (R404.1.2.3.7.4) 3). Safety fence is down & not installed properly. Safety fence must remain in tact during all times that the pool is not being actively worked on with personnel on-site. | |||
| ROW FIELD SURVEY /GRADING CERTIFICATION | 12/11/2023 | APPROVED | TPOLACEK |
| Note: 12/11/23 UPON WALKING PROPERTY DETERMINED THERE ARE NO ADVERSE DRAINAGE CONDITIONS At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved ___________________________________________________________________________ 11/17/2023 - PREVIOUS INSPECTION NOTES 11/17/23 GRADE IS NOT MATCHED. WATER IS POOLING IN THE MIDDLE, NOT MOVING FORWARD. NEED TO MATCH GRADE OD EXISTING SOD. SEE PHOTO FOR REFERENCE. 8/14/2023 - PREVIOUS INSPECTION NOTES NEED TO FIX DRAINAGE ON LEFT SIDE OF HOUSE WATER IS SITTING | |||
| ROW - FINAL INSPECTION | 12/11/2023 | APPROVED - AS NOTED | TPOLACEK |
| Note: 12/11/23 UPON WALKING PROPERTY DETERMINED THERE ARE NO ADVERSE DRAINAGE CONDITIONS At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved ** NO ROW DAMAGE PRESENT AT TIME OF THIS INSPECTION _________________________________________________________________ 12/8/2023 - PREVIOUS INSPECTION NOTES 11/17/2023 - PREVIOUS INSPECTION NOTES 11/17/23 GRADE IS NOT MATCHED. WATER IS POOLING IN THE MIDDLE, NOT MOVING FORWARD. NEED TO MATCH GRADE OF EXISTING SOD. A FIELD SURVEY WAS NOT SCHEDULED PRIR TO THIS INSPECTION, SO YOU WERE FEE'D ON YUOR FIELD, I WILL NOT FEE YOU ON THIS INSPECTION. NEED TO MAKE CORRECTIONS BEFORE SCHEDULING FINAL INSPECTION. SEE PHOTO FOR REFERENCE. __________________________________________________________________________________________________________________________ 8/14/2023 - PREVIOUS INSPECTION NOTES NEED TO FIX DRAINAGE ON LEFT SIDE OF HOUSE WATER IS SITTING. 8/16/2023 - PREVIOUS INSPECTION NOTES NEED TO FIX AREA ON THE LEFT SIDE OF HOUSE WATER IS SITTING AND WAY TO WET | |||
| U -UTILITY RESIDENTIAL FINAL | 12/11/2023 | CANCELLED BY APPLICANT | TPOLACEK |
| Note: SORRY lARRY SCHEDULED BY ACCIDENT | |||
| U -UTILITY RESIDENTIAL FINAL | 12/11/2023 | FINAL APPROVED | JHARDING |
| Note: 12/8/2023 - PREVIOUS INSPECTION NOTES SORRY lARRY SCHEDULED BY ACCIDENT | |||
| ROW - FINAL INSPECTION | 12/08/2023 | CANCELLED BY APPLICANT | TPOLACEK |
| Note: 11/17/2023 - PREVIOUS INSPECTION NOTES 11/17/23 GRADE IS NOT MATCHED. WATER IS POOLING IN THE MIDDLE, NOT MOVING FORWARD. NEED TO MATCH GRADE OF EXISTING SOD. A FIELD SURVEY WAS NOT SCHEDULED PRIR TO THIS INSPECTION, SO YOU WERE FEE'D ON YUOR FIELD, I WILL NOT FEE YOU ON THIS INSPECTION. NEED TO MAKE CORRECTIONS BEFORE SCHEDULING FINAL INSPECTION. SEE PHOTO FOR REFERENCE. __________________________________________________________________________________________________________________________ 8/14/2023 - PREVIOUS INSPECTION NOTES NEED TO FIX DRAINAGE ON LEFT SIDE OF HOUSE WATER IS SITTING. 8/16/2023 - PREVIOUS INSPECTION NOTES NEED TO FIX AREA ON THE LEFT SIDE OF HOUSE WATER IS SITTING AND WAY TO WET | |||
| ROW - FINAL INSPECTION | 11/17/2023 | Disapproved - NO FEE | FSLADISH |
| Note: 11/17/23 GRADE IS NOT MATCHED. WATER IS POOLING IN THE MIDDLE, NOT MOVING FORWARD. NEED TO MATCH GRADE OF EXISTING SOD. A FIELD SURVEY WAS NOT SCHEDULED PRIR TO THIS INSPECTION, SO YOU WERE FEE'D ON YUOR FIELD, I WILL NOT FEE YOU ON THIS INSPECTION. NEED TO MAKE CORRECTIONS BEFORE SCHEDULING FINAL INSPECTION. SEE PHOTO FOR REFERENCE. __________________________________________________________________________________________________________________________ 8/14/2023 - PREVIOUS INSPECTION NOTES NEED TO FIX DRAINAGE ON LEFT SIDE OF HOUSE WATER IS SITTING. 8/16/2023 - PREVIOUS INSPECTION NOTES NEED TO FIX AREA ON THE LEFT SIDE OF HOUSE WATER IS SITTING AND WAY TO WET | |||
| ROW FIELD SURVEY /GRADING CERTIFICATION | 11/17/2023 | Disapproved -FEE REQUIRED | FSLADISH |
| Note: 11/17/23 GRADE IS NOT MATCHED. WATER IS POOLING IN THE MIDDLE, NOT MOVING FORWARD. NEED TO MATCH GRADE OD EXISTING SOD. SEE PHOTO FOR REFERENCE. 8/14/2023 - PREVIOUS INSPECTION NOTES NEED TO FIX DRAINAGE ON LEFT SIDE OF HOUSE WATER IS SITTING | |||
| ROW - FINAL INSPECTION | 08/16/2023 | Disapproved - NO FEE | PFLANAGAN |
| Note: NEED TO FIX AREA ON THE LEFT SIDE OF HOUSE WATER IS SITTING AND WAY TO WET | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 08/14/2023 | APPROVED | PFLANAGAN |
| Note: At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved. | |||
| ROW FIELD SURVEY /GRADING CERTIFICATION | 08/14/2023 | Disapproved - NO FEE | PFLANAGAN |
| Note: NEED TO FIX DRAINAGE ON LEFT SIDE OF HOUSE WATER IS SITTING | |||
| ELECTRIC AND ALARM | 06/14/2023 | APPROVED - AS NOTED | RSIMS |
| Note: 6/14/23: Will need the following items resolved before Pool Final can be approved. 1). Pool heater only has one anchor. Requires 4 anchors. 2). Free standing Hot Tub - cover will need to be removed to verify proper grounding/bonding, wire size and breaker size. | |||
| POOL DECK | 05/09/2023 | APPROVED - AS NOTED | RSIMS |
| Note: 5/9/23: I had to secure the safety fence for you. Please make sure it stays in place (as required) while not working. 5/5/2023 - PREVIOUS INSPECTION NOTES 5/5/23: 1). Footer does not consistently follow any of the approved footers on the Master Pool plan. 2). Clearance to rebar is not met in multiple places. (R404.1.2.3.7.4) 3). Safety fence is down & not installed properly. Safety fence must remain in tact during all times that the pool is not being actively worked on with personnel on-site. | |||
| POOL DECK | 05/05/2023 | Disapproved -FEE REQUIRED | RSIMS |
| Note: 5/5/23: 1). Footer does not consistently follow any of the approved footers on the Master Pool plan. 2). Clearance to rebar is not met in multiple places. (R404.1.2.3.7.4) 3). Safety fence is down & not installed properly. Safety fence must remain in tact during all times that the pool is not being actively work on with personnel on-site. | |||
| STEEL AND GROUND | 03/27/2023 | APPROVED | RSIMS |
Review History
| Department | Status | Date In | Date Out |
| ZON | COMPLETE | 02/27/2023 | 02/27/2023 |
| Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM | |||
| ELEC | COMPLETE | 02/08/2023 | 02/09/2023 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 02/08/2023 | 02/09/2023 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| ZON | HOLD | 02/08/2023 | 02/08/2023 |
| Note: Held By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM Waiting on screen enclosure for review | |||
| BLD | COMPLETE | 02/08/2023 | 02/14/2023 |
| Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM | |||
| BLD | HOLD | 01/30/2023 | 02/01/2023 |
| Note: Held By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM Provide a current City of Palm Coast Pool Safety Form. | |||
| ELEC | HOLD | 01/30/2023 | 01/31/2023 |
| Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM Need to reference the correct NEC code year. note 21 | |||
| MECH | HOLD | 01/30/2023 | 01/31/2023 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Provide completed City of Palm Coast TDH form found on city portal | |||
| SW1 | COMPLETE | 01/30/2023 | 02/03/2023 |
| Note: Released By: EDWARD MADISON - - EMADISON@PALMCOASTGOV.COM | |||
| ZON | HOLD | 01/30/2023 | 02/01/2023 |
| Note: Held By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM Waiting on screen enclosure for review . |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION RESIDENTIAL | ¤40.00 | 12/14/2023 |
| SW ENG REINSPECTION 20 | ¤20.00 | 12/08/2023 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 05/08/2023 |
| SW ENG - REVIEW 20 | ¤20.00 | 02/27/2023 |
| SITE PLAN 30 | ¤30.00 | 02/27/2023 |
| SURCHARGE FS 533.721 | ¤2.00 | 02/27/2023 |
| SURCHARGE - FS 468.631 | ¤2.00 | 02/27/2023 |
| SW ENG INSPECTION 40 | ¤40.00 | 02/27/2023 |
| ADJUSTMENT 50% | (¤127.50) | 02/27/2023 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 02/27/2023 |
| INSPECTION- POOL | ¤160.00 | 02/27/2023 |
| PLAN REVIEW - RESIDENTIAL | ¤65.00 | 02/27/2023 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤321.50 |