I want to search for...
Permit #2023020091
Permit Details
Status: COED
| Parcel Id: 07-11-31-7065-00160-0090 |
| CONDITIONED SPACE: 2362 sqft |
| GARAGE: 547 sqft |
| OPENED PORCH (WITH ROOF) : 330 sqft |
| OPENED PORCH (WITH ROOF) : 111 sqft |
| Total Square Footage: 3350 sqft |
| Block: 00160 |
| Subdivision: 2169 - SECTION 65-KANKAKEE RUN |
| Job Phone: 386-931-5935 |
| Location Address: 5 KASLO CT |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 03/16/2023 |
| NOC: RECORDED |
| Applicant name: RYAN JAMES PERRY |
| Owner: MONKEVITCH EUGENE |
|
Address STE2 PALM COAST, FL 32137 |
|
Address 389 PALM COAST PKWY SW PALM COAST, FL 32137 |
| Lot: 0090 |
| Contracted Stated Job Value: ¤350,000.00 |
| Job Description: SINGLE FAMILY RESIDENCE |
| Type: CN |
Contractor
WATERSIDE HOMES RENOVATIONS AND DESIGNS INC
| Status | Location Address | State License Number | Phone |
| ACTIVE |
10 BISCAYNE DRIVE PALM COAST, FL 32137 |
CBC1263021 (Exp: 08/31/2026) | 386-931-5395 |
Sub Contractors
GARY LLOYD SHEFFIELD
| Status | Location Address | State License Number | Phone |
| ACTIVE |
PO BOX 912 PALM COAST, FL 32164 |
CAC1820539 (Exp: 08/31/2026) | 386-264-0550 |
DILLON CARRERAS
| Status | Location Address | State License Number |
| ACTIVE |
3504 LUNDY ROAD PALATKA, FL 32177 |
EC13010133 (Exp: 08/31/2026) |
RYAN JAMES PERRY
| Status | Location Address | State License Number | Phone |
| ACTIVE |
10 BISCAYNE DRIVE PALM COAST, FL 32137 |
CBC1263021 (Exp: 08/31/2026) | 386-931-5395 |
JUAN CARLOS GONZALEZ
| Status | Location Address | State License Number |
| ACTIVE |
1328 COUNTY ROAD 308 CRESCENT CITY, FL 32112 |
RF11067806 (Exp: 08/31/2027) |
STEPHEN COURTEAUX
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
85 North Yonge Street Ormond Beach, FL 32174 |
EC13001748 (Exp: 08/31/2026) | (386) 672-4900 | 386-676-7472 |
Inspection History
| Type | Request Date | Result | Inspector |
| ROW - FINAL INSPECTION | 04/23/2024 | APPROVED - AS NOTED | GBERTOLA |
| Note: 4/22/24= CORRECTION WERE MADE / PICTURERS ATTACHED AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. THIS INCLUDES BUT IS NOT LIMITED TO THE CULVERT PIPE ELEVATION APPROVAL FOR THE CONCRETE POUR. +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 4/17/2024 - PREVIOUS INSPECTION NOTES 4/17/24=SOME AREAS NEED TO BE ADDRESSED AS WE HAVEN'T NOTICED MUCH CHANGE, PARTICULARLY IN THE BACK LEFT CORNER WHERE THERE HASN'T BEEN ANY IMPROVEMENT AT ALL. I'VE MARKED THE AREAS WITH SPRAY PAINT THAT REQUIRE ATTENTION.. ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 4/4/2024 - PREVIOUS INSPECTION NOTES 4/4/24=ON THE BACK PROPERTY LINE, WE NEED TO RAISE THE TOP PART OF THE SLOPE TO PREVENT WATER FROM FLOWING TO THE BACK NEIGHBORING LOT. ON THE LEFT SIDE, WE HAVE REQUESTED YOU TO RAISE THE SLOPE IN THE BACK, BUT YOU HAVE JUST THROWN THE GRASS ON TOP OF THE EXISTING GRASS. WE KINDLY REQUEST YOU TO PICK UP ALL THE GARBAGE AROUND THE PROPERTY, MOVE AND REPAIR THE PORT-LET FROM THE SWALE AND PLACE IT ON YOUR DRIVEWAY. ONLY PARREN- GABE OR rOBERT NEED TO DO THE INSPECTION 10/10/23 YOU NEED TO MOVE YOUR PORTA POTTY ON SITE OFF THE EDGE OF ROAD. WILL BE BACK FOR REINSPECTION 10/12/23 FOR COMPLIANCE. | |||
| ROW - FINAL INSPECTION | 04/16/2024 | Disapproved - NO FEE | GBERTOLA |
| Note: 4/17/24=SOME AREAS NEED TO BE ADDRESSED AS WE HAVEN'T NOTICED MUCH CHANGE, PARTICULARLY IN THE BACK LEFT CORNER WHERE THERE HASN'T BEEN ANY IMPROVEMENT AT ALL. I'VE MARKED THE AREAS WITH SPRAY PAINT THAT REQUIRE ATTENTION.. ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 4/4/2024 - PREVIOUS INSPECTION NOTES 4/4/24=ON THE BACK PROPERTY LINE, WE NEED TO RAISE THE TOP PART OF THE SLOPE TO PREVENT WATER FROM FLOWING TO THE BACK NEIGHBORING LOT. ON THE LEFT SIDE, WE HAVE REQUESTED YOU TO RAISE THE SLOPE IN THE BACK, BUT YOU HAVE JUST THROWN THE GRASS ON TOP OF THE EXISTING GRASS. WE KINDLY REQUEST YOU TO PICK UP ALL THE GARBAGE AROUND THE PROPERTY, MOVE AND REPAIR THE PORT-LET FROM THE SWALE AND PLACE IT ON YOUR DRIVEWAY. ONLY PARREN- GABE OR rOBERT NEED TO DO THE INSPECTION 10/10/23 YOU NEED TO MOVE YOUR PORTA POTTY ON SITE OFF THE EDGE OF ROAD. WILL BE BACK FOR REINSPECTION 10/12/23 FOR COMPLIANCE. | |||
| ROW- PROJECT STATUS | 04/09/2024 | APPROVED | GBERTOLA |
| Note: Have a meeting with the builder. | |||
| BLD - BUILDING FINAL | 04/04/2024 | Approval - Private Provider | PPROVIDER |
| ROW - FINAL INSPECTION | 04/04/2024 | Disapproved - NO FEE | GBERTOLA |
| Note: 4/4/24=ON THE BACK PROPERTY LINE, WE NEED TO RAISE THE TOP PART OF THE SLOPE TO PREVENT WATER FROM FLOWING TO THE BACK NEIGHBORING LOT. ON THE LEFT SIDE, WE HAVE REQUESTED YOU TO RAISE THE SLOPE IN THE BACK, BUT YOU HAVE JUST THROWN THE GRASS ON TOP OF THE EXISTING GRASS. WE KINDLY REQUEST YOU TO PICK UP ALL THE GARBAGE AROUND THE PROPERTY, MOVE AND REPAIR THE PORT-LET FROM THE SWALE AND PLACE IT ON YOUR DRIVEWAY. ONLY PARREN- GABE OR rOBERT NEED TO DO THE INSPECTION 10/10/23 YOU NEED TO MOVE YOUR PORTA POTTY ON SITE OFF THE EDGE OF ROAD. WILL BE BACK FOR REINSPECTION 10/12/23 FOR COMPLIANCE. | |||
| ROW - STORMWATER FINAL | 03/28/2024 | APPROVED | TPOLACEK |
| Note: 03/28/24 AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET.NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. Inspector Notes from Inspection 9465 03/21/24 CORRECTIONS HAVE BEEN MADE TO BACK LINE, SWALE AND BACK YARD. THE RIGHT SIDE PROPERTY LINE LOOKS BETTER. I WILL APPROVE THE FIELD AND MAKE A NOTE FOR FINAL ROW TO CHECK. BUILDER SHOULD CHECK SURE THE AREA BETWEEN PATIO AND AC UNIT ALONG PROPERTY LINE HAS BACK TO FRONT FALL AND NOT JUST DRAIN INTO VACANT. Negatively impact Section 300.01 (A)(1)(C)(6) Section 300.01 (A)(1)(C)(6). The subject lots drainage must not negatively impact any adjacent property. (B) ------------------------------------------------------------------------------------------------------------------------------- 3/13/2024 - PREVIOUS INSPECTION NOTES 1) THE DRAINAGE FEATURE IN THE BACK YARD IS HOLDING WATER NEED TO FIX SO WATER WILL FLOW TO FRONT ROADSIDE SWALE. WITH THE SIDES DRY THAT MEANS HAT THE WATER IS NOT ABLE TO DRAIN PROPERLY. 2) THE DRAINAGE ON THE RIGHT SIDE OF HOUSE DOESN'T HAVE POSITIVE FALL FROM BACK TO FRONT DO TO LOW AREAS AND HIGH SPOTS. Sec.300.01 (4,5,6) The tolerance along side lot lines is no more than 20 feet, with positive fall on each side. Positive fall is considered to be 0.10 feet in 20 feet. The minimum fall from the rear property line to the front is 0.50 feet. 3) THE DRAINAGE ON THE RIGHT AT THE FRONT RIGHT OF WAY LINE JUST GOES INTO BRUSH NEED TO DIVERT THE WATER AROUND AND NOT LET IT GO INTO THE PEP TANK. 4) ALSO PER GABE AND ME NEED TO BUILD THE BACK HIGH POINT HIGHER SO THE WATER WILL NOT IMPACT THE ADJACENT LOT AREA IS PAINTED FOR CLEARIFCATION. --------------------------------------------------------------------------------------------- 3/7/2024 - PREVIOUS INSPECTION NOTES 1) THE DRAINAGE FEATURE IN THE BACK YARD IS HOLDING WATER NEED TO FIX SO WATER WILL FLOW TO FRONT ROADSIDE SWALE. WITH THE SIDES DRY THAT MEANS HAT THE WATER IS NOT ABLE TO DRAIN PROPERLY. 2) THE DRAINAGE ON THE RIGHT SIDE OF HOUSE DOESN'T HAVE POSITIVE FALL FROM BACK TO FRONT DO TO LOW AREAS AND HIGH SPOTS. Sec.300.01 (4,5,6) The tolerance along side lot lines is no more than 20 feet, with positive fall on each side. Positive fall is considered to be 0.10 feet in 20 feet. The minimum fall from the rear property line to the front is 0.50 feet. 3) THE DRAINAGE ON THE RIGHT AT THE FRONT RIGHT OF WAY LINE JUST GOES INTO BRUSH NEED TO DIVERT THE WATER AROUND AND NOT LET IT GO INTO THE PEP TANK. ---------------------------------------------------------------------------------------------------------- rjg 3/5/24. Pictures sent in from the house behind seemed to show the left rear grade is not high enough and is allowing water to drain onto the rear adjacent lot. Please double check before finals are approved. | |||
| U -UTILITY RESIDENTIAL FINAL | 03/28/2024 | FINAL APPROVED | JHARDING |
| ROW - FINAL APRON (AFTER POUR) | 03/28/2024 | APPROVED | TPOLACEK |
| Note: 03/28/24 CONCRETE IS GOOD CUTS ARE MADE CULVERT CLEAR AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET.NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. Inspector Notes from Inspection 9465 03/21/24 CORRECTIONS HAVE BEEN MADE TO BACK LINE, SWALE AND BACK YARD. THE RIGHT SIDE PROPERTY LINE LOOKS BETTER. I WILL APPROVE THE FIELD AND MAKE A NOTE FOR FINAL ROW TO CHECK. BUILDER SHOULD CHECK SURE THE AREA BETWEEN PATIO AND AC UNIT ALONG PROPERTY LINE HAS BACK TO FRONT FALL AND NOT JUST DRAIN INTO VACANT. Negatively impact Section 300.01 (A)(1)(C)(6) Section 300.01 (A)(1)(C)(6). The subject lots drainage must not negatively impact any adjacent property. (B) ------------------------------------------------------------------------------------------------------------------------------- 3/13/2024 - PREVIOUS INSPECTION NOTES 1) THE DRAINAGE FEATURE IN THE BACK YARD IS HOLDING WATER NEED TO FIX SO WATER WILL FLOW TO FRONT ROADSIDE SWALE. WITH THE SIDES DRY THAT MEANS HAT THE WATER IS NOT ABLE TO DRAIN PROPERLY. 2) THE DRAINAGE ON THE RIGHT SIDE OF HOUSE DOESN'T HAVE POSITIVE FALL FROM BACK TO FRONT DO TO LOW AREAS AND HIGH SPOTS. Sec.300.01 (4,5,6) The tolerance along side lot lines is no more than 20 feet, with positive fall on each side. Positive fall is considered to be 0.10 feet in 20 feet. The minimum fall from the rear property line to the front is 0.50 feet. 3) THE DRAINAGE ON THE RIGHT AT THE FRONT RIGHT OF WAY LINE JUST GOES INTO BRUSH NEED TO DIVERT THE WATER AROUND AND NOT LET IT GO INTO THE PEP TANK. 4) ALSO PER GABE AND ME NEED TO BUILD THE BACK HIGH POINT HIGHER SO THE WATER WILL NOT IMPACT THE ADJACENT LOT AREA IS PAINTED FOR CLEARIFCATION. --------------------------------------------------------------------------------------------- 3/7/2024 - PREVIOUS INSPECTION NOTES 1) THE DRAINAGE FEATURE IN THE BACK YARD IS HOLDING WATER NEED TO FIX SO WATER WILL FLOW TO FRONT ROADSIDE SWALE. WITH THE SIDES DRY THAT MEANS HAT THE WATER IS NOT ABLE TO DRAIN PROPERLY. 2) THE DRAINAGE ON THE RIGHT SIDE OF HOUSE DOESN'T HAVE POSITIVE FALL FROM BACK TO FRONT DO TO LOW AREAS AND HIGH SPOTS. Sec.300.01 (4,5,6) The tolerance along side lot lines is no more than 20 feet, with positive fall on each side. Positive fall is considered to be 0.10 feet in 20 feet. The minimum fall from the rear property line to the front is 0.50 feet. 3) THE DRAINAGE ON THE RIGHT AT THE FRONT RIGHT OF WAY LINE JUST GOES INTO BRUSH NEED TO DIVERT THE WATER AROUND AND NOT LET IT GO INTO THE PEP TANK. ---------------------------------------------------------------------------------------------------------- rjg 3/5/24. Pictures sent in from the house behind seemed to show the left rear grade is not high enough and is allowing water to drain onto the rear adjacent lot. Please double check before finals are approved. | |||
| ROW FIELD SURVEY /GRADING CERTIFICATION | 03/21/2024 | APPROVED - AS NOTED | TPOLACEK |
| Note: 03/21/24 CORRECTIONS HAVE BEEN MADE TO BACK LINE, SWALE AND BACK YARD. THE RIGHT SIDE PROPERTY LINE LOOKS BETTER. I WILL APPROVE THE FIELD AND MAKE A NOTE FOR FINAL ROW TO CHECK. BUILDER SHOULD CHECK SURE THE AREA BETWEEN PATIO AND AC UNIT ALONG PROPERTY LINE HAS BACK TO FRONT FALL AND NOT JUST DRAIN INTO VACANT. Negatively impact Section 300.01 (A)(1)(C)(6) Section 300.01 (A)(1)(C)(6). The subject lots drainage must not negatively impact any adjacent property. (B) ------------------------------------------------------------------------------------------------------------------------------- 3/13/2024 - PREVIOUS INSPECTION NOTES 1) THE DRAINAGE FEATURE IN THE BACK YARD IS HOLDING WATER NEED TO FIX SO WATER WILL FLOW TO FRONT ROADSIDE SWALE. WITH THE SIDES DRY THAT MEANS HAT THE WATER IS NOT ABLE TO DRAIN PROPERLY. 2) THE DRAINAGE ON THE RIGHT SIDE OF HOUSE DOESN'T HAVE POSITIVE FALL FROM BACK TO FRONT DO TO LOW AREAS AND HIGH SPOTS. Sec.300.01 (4,5,6) The tolerance along side lot lines is no more than 20 feet, with positive fall on each side. Positive fall is considered to be 0.10 feet in 20 feet. The minimum fall from the rear property line to the front is 0.50 feet. 3) THE DRAINAGE ON THE RIGHT AT THE FRONT RIGHT OF WAY LINE JUST GOES INTO BRUSH NEED TO DIVERT THE WATER AROUND AND NOT LET IT GO INTO THE PEP TANK. 4) ALSO PER GABE AND ME NEED TO BUILD THE BACK HIGH POINT HIGHER SO THE WATER WILL NOT IMPACT THE ADJACENT LOT AREA IS PAINTED FOR CLEARIFCATION. --------------------------------------------------------------------------------------------- 3/7/2024 - PREVIOUS INSPECTION NOTES 1) THE DRAINAGE FEATURE IN THE BACK YARD IS HOLDING WATER NEED TO FIX SO WATER WILL FLOW TO FRONT ROADSIDE SWALE. WITH THE SIDES DRY THAT MEANS HAT THE WATER IS NOT ABLE TO DRAIN PROPERLY. 2) THE DRAINAGE ON THE RIGHT SIDE OF HOUSE DOESN'T HAVE POSITIVE FALL FROM BACK TO FRONT DO TO LOW AREAS AND HIGH SPOTS. Sec.300.01 (4,5,6) The tolerance along side lot lines is no more than 20 feet, with positive fall on each side. Positive fall is considered to be 0.10 feet in 20 feet. The minimum fall from the rear property line to the front is 0.50 feet. 3) THE DRAINAGE ON THE RIGHT AT THE FRONT RIGHT OF WAY LINE JUST GOES INTO BRUSH NEED TO DIVERT THE WATER AROUND AND NOT LET IT GO INTO THE PEP TANK. ---------------------------------------------------------------------------------------------------------- rjg 3/5/24. Pictures sent in from the house behind seemed to show the left rear grade is not high enough and is allowing water to drain onto the rear adjacent lot. Please double check before finals are approved. | |||
| ROW FIELD SURVEY /GRADING CERTIFICATION | 03/13/2024 | Disapproved - NO FEE | PFLANAGAN |
| Note: 1) THE DRAINAGE FEATURE IN THE BACK YARD IS HOLDING WATER NEED TO FIX SO WATER WILL FLOW TO FRONT ROADSIDE SWALE. WITH THE SIDES DRY THAT MEANS HAT THE WATER IS NOT ABLE TO DRAIN PROPERLY. 2) THE DRAINAGE ON THE RIGHT SIDE OF HOUSE DOESN'T HAVE POSITIVE FALL FROM BACK TO FRONT DO TO LOW AREAS AND HIGH SPOTS. Sec.300.01 (4,5,6) The tolerance along side lot lines is no more than 20 feet, with positive fall on each side. Positive fall is considered to be 0.10 feet in 20 feet. The minimum fall from the rear property line to the front is 0.50 feet. 3) THE DRAINAGE ON THE RIGHT AT THE FRONT RIGHT OF WAY LINE JUST GOES INTO BRUSH NEED TO DIVERT THE WATER AROUND AND NOT LET IT GO INTO THE PEP TANK. 4) ALSO PER GABE AND ME NEED TO BUILD THE BACK HIGH POINT HIGHER SO THE WATER WILL NOT IMPACT THE ADJACENT LOT AREA IS PAINTED FOR CLEARIFCATION. --------------------------------------------------------------------------------------------- 3/7/2024 - PREVIOUS INSPECTION NOTES 1) THE DRAINAGE FEATURE IN THE BACK YARD IS HOLDING WATER NEED TO FIX SO WATER WILL FLOW TO FRONT ROADSIDE SWALE. WITH THE SIDES DRY THAT MEANS HAT THE WATER IS NOT ABLE TO DRAIN PROPERLY. 2) THE DRAINAGE ON THE RIGHT SIDE OF HOUSE DOESN'T HAVE POSITIVE FALL FROM BACK TO FRONT DO TO LOW AREAS AND HIGH SPOTS. Sec.300.01 (4,5,6) The tolerance along side lot lines is no more than 20 feet, with positive fall on each side. Positive fall is considered to be 0.10 feet in 20 feet. The minimum fall from the rear property line to the front is 0.50 feet. 3) THE DRAINAGE ON THE RIGHT AT THE FRONT RIGHT OF WAY LINE JUST GOES INTO BRUSH NEED TO DIVERT THE WATER AROUND AND NOT LET IT GO INTO THE PEP TANK. ---------------------------------------------------------------------------------------------------------- rjg 3/5/24. Pictures sent in from the house behind seemed to show the left rear grade is not high enough and is allowing water to drain onto the rear adjacent lot. Please double check before finals are approved. | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 03/07/2024 | APPROVED | PFLANAGAN |
| Note: At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved. ---------------------------------------------------------------------------- rjg 3/5/24. Pictures sent in from the house behind seemed to show the left rear grade is not high enough and is allowing water to drain onto the rear adjacent lot. Please double check before finals are approved. 3/1/2024 - PREVIOUS INSPECTION NOTES LEFT CULVERT PIPE IS OUT OF TOLERANCE TO SWALE PLAN DIAGRAM. RIGHT CULVERT PIPE IS SHOWING 19.30 TO 19.37 (BACKPITCHED) AND IS ALSO OUT OF TOLERANCE TO SWALE PLAN DIAGRAM. NEED TO RESHOOT THESE PIPE ELEVATIONS FOR ACCURACY TO DETERMINE IF THE PIPE IS INDEED OUT OF TOLERANCE. Inspector Notes from Inspection 9470 2/23/24 UPON WALKING THE PROPERTY, IN THE REAR WITH THE EXCEPTION OF A SMALL ANOMOLY ON THE LEFT SIDE, THE REAR PROPERTY LINE SLOPE IS WITHIN COPC SPECIFICATIONS AND STANDARDS AT THE TIME THIS INSPECTION WAS DONE. THERE IS NO STANDING WATER AT THE TIME OF THIS INSPECTION. PHOTOS ENCLOSED FOR REFERENCE. THE PROPERTY PERMIT HAS NOT BEEN CALLED IN FOR ANY STORMWATER INSPECTIONS AS OF YET. WHEN A SURVEY IS SUBMITTED WE WILL VERIFY ELEVATION NUMBERS AND UNTIL THEN MONITOR THIS SITE. The above property was inspected by Code Enforcement for action order (2024020861) that was received on 2/20/24.The property has water in the rear yard which appears from the new build behind his property. They graded the back yard at 5 Kaslo Ct. toward Mr Luckett's fence. Please see the pictures that document the issue. | |||
| ROW FIELD SURVEY /GRADING CERTIFICATION | 03/07/2024 | Disapproved - NO FEE | PFLANAGAN |
| Note: 1) THE DRAINAGE FEATURE IN THE BACK YARD IS HOLDING WATER NEED TO FIX SO WATER WILL FLOW TO FRONT ROADSIDE SWALE. WITH THE SIDES DRY THAT MEANS HAT THE WATER IS NOT ABLE TO DRAIN PROPERLY. 2) THE DRAINAGE ON THE RIGHT SIDE OF HOUSE DOESN'T HAVE POSITIVE FALL FROM BACK TO FRONT DO TO LOW AREAS AND HIGH SPOTS. Sec.300.01 (4,5,6) The tolerance along side lot lines is no more than 20 feet, with positive fall on each side. Positive fall is considered to be 0.10 feet in 20 feet. The minimum fall from the rear property line to the front is 0.50 feet. 3) THE DRAINAGE ON THE RIGHT AT THE FRONT RIGHT OF WAY LINE JUST GOES INTO BRUSH NEED TO DIVERT THE WATER AROUND AND NOT LET IT GO INTO THE PEP TANK. ---------------------------------------------------------------------------------------------------------- rjg 3/5/24. Pictures sent in from the house behind seemed to show the left rear grade is not high enough and is allowing water to drain onto the rear adjacent lot. Please double check before finals are approved. | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 03/01/2024 | Disapproved - NO FEE | FSLADISH |
| Note: LEFT CULVERT PIPE IS OUT OF TOLERANCE TO SWALE PLAN DIAGRAM. RIGHT CULVERT PIPE IS SHOWING 19.30 TO 19.37 (BACKPITCHED) AND IS ALSO OUT OF TOLERANCE TO SWALE PLAN DIAGRAM. NEED TO RESHOOT THESE PIPE ELEVATIONS FOR ACCURACY TO DETERMINE IF THE PIPE IS INDEED OUT OF TOLERANCE. Inspector Notes from Inspection 9470 2/23/24 UPON WALKING THE PROPERTY, IN THE REAR WITH THE EXCEPTION OF A SMALL ANOMOLY ON THE LEFT SIDE, THE REAR PROPERTY LINE SLOPE IS WITHIN COPC SPECIFICATIONS AND STANDARDS AT THE TIME THIS INSPECTION WAS DONE. THERE IS NO STANDING WATER AT THE TIME OF THIS INSPECTION. PHOTOS ENCLOSED FOR REFERENCE. THE PROPERTY PERMIT HAS NOT BEEN CALLED IN FOR ANY STORMWATER INSPECTIONS AS OF YET. WHEN A SURVEY IS SUBMITTED WE WILL VERIFY ELEVATION NUMBERS AND UNTIL THEN MONITOR THIS SITE. The above property was inspected by Code Enforcement for action order (2024020861) that was received on 2/20/24.The property has water in the rear yard which appears from the new build behind his property. They graded the back yard at 5 Kaslo Ct. toward Mr Luckett's fence. Please see the pictures that document the issue. | |||
| U-CROSS CONNECTION | 03/01/2024 | APPROVED | DHANEY |
| ROW - DRAINAGE | 02/23/2024 | APPROVED - AS NOTED | FSLADISH |
| Note: 2/23/24 UPON WALKING THE PROPERTY, IN THE REAR WITH THE EXCEPTION OF A SMALL ANOMOLY ON THE LEFT SIDE, THE REAR PROPERTY LINE SLOPE IS WITHIN COPC SPECIFICATIONS AND STANDARDS AT THE TIME THIS INSPECTION WAS DONE. THERE IS NO STANDING WATER AT THE TIME OF THIS INSPECTION. PHOTOS ENCLOSED FOR REFERENCE. THE PROPERTY PERMIT HAS NOT BEEN CALLED IN FOR ANY STORMWATER INSPECTIONS AS OF YET. WHEN A SURVEY IS SUBMITTED WE WILL VERIFY ELEVATION NUMBERS AND UNTIL THEN MONITOR THIS SITE. The above property was inspected by Code Enforcement for action order (2024020861) that was received on 2/20/24.The property has water in the rear yard which appears from the new build behind his property. They graded the back yard at 5 Kaslo Ct. toward Mr Luckett's fence. Please see the pictures that document the issue. | |||
| ELECTRIC - EARLY POWER | 02/21/2024 | Approval - Private Provider | PPROVIDER |
| ROW- PRE-APRON (PRE-POUR) | 12/20/2023 | APPROVED | PFLANAGAN |
| Note: CORRECTIONS MADE IT'S YOUR RESPONSIBILITY TO CHECK THE CULVERT ELEVATIONS BEFORE POURING CONCRETE. ALL CONCRETE NEEDS TO BE A MINIMUM OF 3000PSI WITH FIBER OR WITH METAL MESH IN THE CONCRETE TO MEET ALL CITY'S STANDARDS. At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved. -------------------------------------------------------------------------------------------------------- 12/19/2023 - PREVIOUS INSPECTION NOTES 1) THE LEFT DRIVEWAY FACE BOARD IS STILL TO FAR IN THE ROADWAY 2) AFTER ADDING SOIL IN DRIVEWAY POURING AREA THERE ARE AREAS THAT DONT GIVE YOU THE MINIMUM AMOUNT OF CONCRETER ABOVE THE RIGHT OF WAY Sec 400.02 Sidewalks and driveways constructed within the City of Palm Coast shall be constructed with 3000 psi concrete and contain fiber or wire mesh. Sidewalk and driveways above the right of way shall be a minimum of 4" thick concrete. ------------------------------------------------------------------------------ 12/15/2023 - PREVIOUS INSPECTION NOTES 12/15/23 FORMBOARDS AT APRON ARE IN THE ROADWAY, THEY NEED TO BE BACK AT THE EDGE OF ROADWAY AND RUN ALONG IT FOR THE DISTANCE OF THE DRIVEWAY. AREA BEHIND ROW IS TO WET TO POUR, I AM SINKING IN WHILE WAKING. NEEDS TO BE PROPERLY COMPACTED AND DRIED OUT. PIPE WAS GOOD AT THE TIME OF THIS INSPECTION. NOT GOING TO FEE YOU TODAY. PLEASE MAKE NECCESSARY CORRECTIONS BEFORE RESUBMITTING FOR PREPOUR INSPECTION. SEE PHOTO FOR REFERENCE. | |||
| ROW- PRE-APRON (PRE-POUR) | 12/19/2023 | Disapproved -FEE REQUIRED | PFLANAGAN |
| Note: 1) THE LEFT DRIVEWAY FACE BOARD IS STILL TO FAR IN THE ROADWAY 2) AFTER ADDING SOIL IN DRIVEWAY POURING AREA THERE ARE AREAS THAT DONT GIVE YOU THE MINIMUM AMOUNT OF CONCRETER ABOVE THE RIGHT OF WAY Sec 400.02 Sidewalks and driveways constructed within the City of Palm Coast shall be constructed with 3000 psi concrete and contain fiber or wire mesh. Sidewalk and driveways above the right of way shall be a minimum of 4" thick concrete. ------------------------------------------------------------------------------ 12/15/2023 - PREVIOUS INSPECTION NOTES 12/15/23 FORMBOARDS AT APRON ARE IN THE ROADWAY, THEY NEED TO BE BACK AT THE EDGE OF ROADWAY AND RUN ALONG IT FOR THE DISTANCE OF THE DRIVEWAY. AREA BEHIND ROW IS TO WET TO POUR, I AM SINKING IN WHILE WAKING. NEEDS TO BE PROPERLY COMPACTED AND DRIED OUT. PIPE WAS GOOD AT THE TIME OF THIS INSPECTION. NOT GOING TO FEE YOU TODAY. PLEASE MAKE NECCESSARY CORRECTIONS BEFORE RESUBMITTING FOR PREPOUR INSPECTION. SEE PHOTO FOR REFERENCE. | |||
| ROW- PRE-APRON (PRE-POUR) | 12/15/2023 | Disapproved - NO FEE | TPOLACEK |
| Note: 12/15/23 FORMBOARDS AT APRON ARE IN THE ROADWAY, THEY NEED TO BE BACK AT THE EDGE OF ROADWAY AND RUN ALONG IT FOR THE DISTANCE OF THE DRIVEWAY. AREA BEHIND ROW IS TO WET TO POUR, I AM SINKING IN WHILE WAKING. NEEDS TO BE PROPERLY COMPACTED AND DRIED OUT. PIPE WAS GOOD AT THE TIME OF THIS INSPECTION. NOT GOING TO FEE YOU TODAY. PLEASE MAKE NECCESSARY CORRECTIONS BEFORE RESUBMITTING FOR PREPOUR INSPECTION. SEE PHOTO FOR REFERENCE. | |||
| GRAVITY SEWER TEST | 12/01/2023 | Approval - Private Provider | PPROVIDER |
| Note: 11/30/2023 1:25:19 PM- PREVIOUS INSPECTION NOTES | |||
| GRAVITY SEWER TEST | 11/28/2023 | CANCELLED BY APPLICANT | PPROVIDER |
| Note: Inspector Notes from Inspection 9450 THIS WAS A VIRTUAL INSPECTION | |||
| U - SEWER TIE IN | 11/28/2023 | APPROVED - AS NOTED | MGIBSON |
| Note: THIS WAS A VIRTUAL INSPECTION | |||
| ROW - DRAINAGE | 10/12/2023 | Disapproved -FEE REQUIRED | FSLADISH |
| Note: 10/12/23 PORTA POTTY STILL NOT MOVED ONTO SITE. BACK FOR REINSPECTION FOR COMPLIANCE ON 10/16/23 ______________________________________________________________________________________________________________________ 10/10/2023 - PREVIOUS INSPECTION NOTES 10/10/23 YOU NEED TO MOVE YOUR PORTA POTTY ON SITE OFF THE EDGE OF ROAD. WILL BE BACK FOR REINSPECTION 10/12/23 FOR COMPLIANCE. ________________________________________________________________________________________________________________________ 10/3/2023 - PREVIOUS INSPECTION NOTES 10/03/23 you need to remove the porta potty from the swale. It is causing water to back up in the swale and not flow to the drainage ditch. Will be back for reinspection for compliance on 10/10/23. | |||
| ROW - DRAINAGE | 10/10/2023 | Disapproved -FEE REQUIRED | FSLADISH |
| Note: 10/10/23 YOU NEED TO MOVE YOUR PORTA POTTY ON SITE OFF THE EDGE OF ROAD. WILL BE BACK FOR REINSPECTION 10/12/23 FOR COMPLIANCE. ________________________________________________________________________________________________________________________ 10/3/2023 - PREVIOUS INSPECTION NOTES 10/03/23 you need to remove the porta potty from the swale. It is causing water to back up in the swale and not flow to the drainage ditch. Will be back for reinspection for compliance on 10/10/23. | |||
| PEP TANK INSTALLATION REQUEST | 10/09/2023 | APPROVED | CBOWERMASTER |
| ROW - DRAINAGE | 10/03/2023 | Disapproved - NO FEE | FSLADISH |
| Note: 10/03/23 you need to remove the porta potty from the swale. It is causing water to back up in the swale and not flow to the drainage ditch. Will be back for reinspection for compliance on 10/10/23. | |||
| INSULATION | 09/18/2023 | Approval - Private Provider | PPROVIDER |
| ALL ROUGH | 09/14/2023 | Approval - Private Provider | PPROVIDER |
| ALL ROUGH | 09/14/2023 | Approval - Private Provider | PPROVIDER |
| ELECTRIC-TUG | 09/14/2023 | Approval - Private Provider | PPROVIDER |
| LATH/BRICK/ WATER BARRIER | 07/28/2023 | Approval - Private Provider | PPROVIDER |
| ROOF VALLEY & METAL | 07/28/2023 | Approval - Private Provider | PPROVIDER |
| WALL SHEATHING | 07/12/2023 | Approval - Private Provider | PPROVIDER |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 07/12/2023 | Approval - Private Provider | PPROVIDER |
| TIE BEAM / LINTEL | 05/31/2023 | Approval - Private Provider | PPROVIDER |
| FOUND SURVEY APPROVED (OFFICE) | 05/04/2023 | APPROVED | TBAKER |
| MONOLITHIC SLAB | 04/18/2023 | Approval - Private Provider | PPROVIDER |
| PLUMBING 1ST ROUGH UNDERGROUND | 04/11/2023 | Approval - Private Provider | PPROVIDER |
| WATER METER INSTALLATION REQUEST | 03/20/2023 | APPROVED | CSTONE |
Review History
| Department | Status | Date In | Date Out |
| BLD | CANCEL | 10/30/2023 | 11/02/2023 |
| ENGIN1 | COMPLETE | 10/30/2023 | 10/31/2023 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 10/30/2023 | 11/13/2023 |
| Note: Released By: JEFF CREWS - - JCREWS@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 10/30/2023 | 10/30/2023 |
| Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 05/03/2023 | 05/04/2023 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 05/03/2023 | 05/03/2023 |
| Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 02/27/2023 | 02/27/2023 |
| Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 02/27/2023 | 03/06/2023 |
| Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 02/27/2023 | 02/27/2023 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 02/02/2023 | 02/08/2023 |
| Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM | |||
| CUSVC | COMPLETE | 02/02/2023 | 02/07/2023 |
| Note: Released By: HALEIGH HAND - - | |||
| ELEC | COMPLETE | 02/02/2023 | 02/03/2023 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 02/02/2023 | 02/02/2023 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| LOCATE | COMPLETE | 02/02/2023 | 02/03/2023 |
| Note: Released By: TONI CHURCHILL - - | |||
| MECH | COMPLETE | 02/02/2023 | 02/06/2023 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| SW1 | HOLD | 02/02/2023 | 02/08/2023 |
| Note: Held By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM WATER IS BEING TRAPED IN THE BACK YARD AND IT IS IMPACTING THE LOT BEHIND YOURS | |||
| ZON | HOLD | 02/02/2023 | 02/03/2023 |
| Note: Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM One additional tree required. | |||
| SWALE | COMPLETE | 02/02/2023 | 05/09/2023 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| CONTRACTOR CHANGE | ¤20.00 | 04/22/2024 |
| SW ENG REINSPECTION 20 | ¤20.00 | 04/22/2024 |
| SW ENG REINSPECTION 30 | ¤30.00 | 04/22/2024 |
| SW ENG - INSPECTION 20 | ¤20.00 | 04/22/2024 |
| SW ENG - INSPECTION 20 | ¤20.00 | 04/22/2024 |
| SW ENG - INSPECTION 20 | ¤20.00 | 04/22/2024 |
| SW ENG - INSPECTION 20 | ¤20.00 | 04/22/2024 |
| SW ENG INSPECTION 80 | ¤80.00 | 03/16/2023 |
| SW ENG PRE APRON | ¤30.00 | 03/16/2023 |
| SW ENG - REVIEW 20 | ¤20.00 | 03/16/2023 |
| SW ENG RES REVIEW 200 | ¤200.00 | 03/16/2023 |
| TRANS IMPACT FEE ADMIN | ¤54.36 | 03/16/2023 |
| TRANS IMPACT FEE ADMIN | (¤54.36) | 03/16/2023 |
| SEWER CREDIT | (¤850.00) | 03/16/2023 |
| SEWER INSPECTION | ¤25.00 | 03/16/2023 |
| SEWER CAPITAL FACILITY | ¤5,344.82 | 03/16/2023 |
| WATER CAPITAL FACILITY FEE | ¤3,923.88 | 03/16/2023 |
| SITE PLAN 30 | ¤30.00 | 03/16/2023 |
| WATER-METER | ¤505.39 | 03/16/2023 |
| WATER- TURN ON | ¤25.00 | 03/16/2023 |
| WATER- TURN ON | ¤25.00 | 03/16/2023 |
| ADJUSTMENT 50% | (¤151.50) | 03/16/2023 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 03/16/2023 |
| ADMINISTRATIVE - RESID PP | ¤225.00 | 03/16/2023 |
| PLAN REVIEW - RESIDENTIAL | ¤273.00 | 03/16/2023 |
| CONNECTION FEES | ¤1,166.26 | 03/16/2023 |
| FIRE IMPACT FEE ADMIN | ¤12.62 | 03/16/2023 |
| FIRE IMPACT FEE ADMIN | (¤12.62) | 03/16/2023 |
| FC IMPACT FEE EMS | ¤62.00 | 03/16/2023 |
| IMPACT FEE FIRE | ¤420.52 | 03/16/2023 |
| FC IMPACT FEE LAW ENFORCEMENT | ¤218.00 | 03/16/2023 |
| FC IMPACT FEE LIBRARY | ¤268.00 | 03/16/2023 |
| IMPACT FEE PARKS | ¤1,769.15 | 03/16/2023 |
| IMPACT FEE SCHOOL | ¤5,450.00 | 03/16/2023 |
| IMPACT FEE TRANSPORTATION | ¤1,812.00 | 03/16/2023 |
| WATER -IRRIGATION INSPECTION | ¤25.00 | 03/16/2023 |
| WATER -IRRIGATION INSPECTION | ¤25.00 | 03/16/2023 |
| PARKS IMPACT FEE ADMIN | ¤53.07 | 03/16/2023 |
| PARKS IMPACT FEE ADMIN | (¤53.07) | 03/16/2023 |
| SURCHARGE FS 533.721 | ¤2.00 | 03/16/2023 |
| SURCHARGE - FS 468.631 | ¤2.06 | 03/16/2023 |
| SW ENG - FOUNDATION SURVEY | ¤20.00 | 03/16/2023 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤21,125.58 |