I want to search for...

Permit #2023020413

Permit Details

Status: COED

Parcel Id: 07-11-31-7034-00410-0170
Total Square Footage: 4248 sqft
Block: 00410
Subdivision: 2165 - SECTION 34-EASTHAMPTON
Job Phone: 786-440-4283
Location Address: 22 EASTERLY PL
Type: RF - REROOF
Issue Date: 02/09/2023
NOC: RECORDED
Applicant name: GABRIELA VENEGAS
Owner: POLANSK TATYANA & GREGORY POLANSKY

Address

22 EASTERLY PL #B

PALM COAST, FL 32164

Lot: 0170
Contracted Stated Job Value: ¤21,775.00
Job Description: REROOF
Type: CN

Contractor

DOGA CONSTRUCTION, INC
Status Location Address State License Number Phone
INACTIVE

5541 NW 74 AVE

MIAMI, FL 33166

CCC1333736 (Exp: 08/31/2026) 786-440-4283

Inspection History

Type Request Date Result Inspector
ROOF FINAL 02/23/2023 FINAL APPROVED BTAYLOR
Note: 2/22/2023 - PREVIOUS INSPECTION NOTES 2/22/23: Unit B wire screen is not removed from the dryer vent as required. (check both) 2/14/23: Will need revision submitted to & approved by the City for different underlayment (ABC Proguard) used before scheduling Roof Final Inspection. - Roofing worksheet lists Owens Corning.
ROOF FINAL 02/22/2023 Disapproved -FEE REQUIRED RSIMS
Note: 2/22/23: Unit B wire screen is not removed from the dryer vent as required. (check both) 2/14/23: Will need revision submitted to & approved by the City for different underlayment (ABC Proguard) used before scheduling Roof Final Inspection. - Roofing worksheet lists Owens Corning.
ROOF AFFIDAVIT 02/21/2023 APPROVED STHOMAS
ROOF IN PROGRESS- MIDROOF 02/17/2023 APPROVED TSTAUFFACHER
Note: 2/14/2023 - PREVIOUS INSPECTION NOTES 2/14/23: Will need revision submitted to & approved by the City for different underlayment (ABC Proguard) used before scheduling Roof Final Inspection. - Roofing worksheet lists Owens Corning. *** Please do not install more than 25% of shingles for a Mid-roof inspection. 1). Right valley has synthetic underlayment that is installed vertically down the valley. All synthethic underlayment must be run horizontally accross roof plane. 2). Nail depth on shingles inspected is too deep and penetrating through the shingle. Left side hip inspected. Please check all and repair/replace where needed & make sure you are following the manufacturer's nailing requirements.
ROOF IN PROGRESS- MIDROOF 02/14/2023 Disapproved -FEE REQUIRED RSIMS
Note: 2/14/23: Will need revision submitted to & approved by the City for different underlayment (ABC Proguard) used before scheduling Roof Final Inspection. - Roofing worksheet lists Owens Corning. *** Please do not install more than 25% of shingles for a Mid-roof inspection. 1). Right valley has synthetic underlayment that is installed vertically down the valley. All synthethic underlayment must be run horizontally accross roof plane. 2). Nail depth on shingles inspected is too deep and penetrating through the shingle. Left side hip inspected. Please check all and repair/replace where needed & make sure you are following the manufacturer's nailing requirements.

Review History

Department Status Date In Date Out
BLD COMPLETE 02/22/2023 02/23/2023
Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM
BLD COMPLETE 02/17/2023 02/21/2023
Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM
BADMIN COMPLETE 02/13/2023 02/13/2023
Note: Released By: SCOTT THOMAS - - STHOMAS@PALMCOASTGOV.COM DATE MISSING ROOFING AFFIDAVIT
BLD COMPLETE 02/09/2023 02/09/2023
Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
PLAN REVIEW - REVISION ¤32.50 02/24/2023
REINSPECTION RESIDENTIAL ¤40.00 02/22/2023
PLAN REVIEW - REVISION ¤32.50 02/21/2023
REINSPECTION RESIDENTIAL ¤40.00 02/20/2023
ADJUSTMENT 50% (¤45.25) 02/09/2023
ADMINISTRATIVE RESIDENTIAL ¤30.00 02/09/2023
INSPECTION - RESIDENTIAL ¤60.50 02/09/2023
SURCHARGE FS 533.721 ¤2.00 02/09/2023
SURCHARGE - FS 468.631 ¤2.00 02/09/2023
Fees Total Due: ¤0.00 Total Paid: ¤194.25