I want to search for...

Permit #2023020529

Permit Details

Status: COED

Parcel Id: 07-11-31-7023-00210-0340
CONDITIONED SPACE: 2023 sqft
GARAGE: 724 sqft
SCREEN PORCH (SOLID ROOF) : 150 sqft
OPENED PORCH (WITH ROOF) : 60 sqft
Total Square Footage: 2957 sqft
Block: 00210
Subdivision: 2191 - SECTION 23-WYNNFIELD
Job Phone: 386-237-8427
Location Address: 28 WHITTINGTON DR
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 02/22/2023
NOC: RECORDED
Applicant name: JAY DARREN CURBOW
Owner: BLUE WATER HOMES INC

Address

6 LA MANCHA DRIVE

PALM COAST, FL 32137

Lot: 0340
Contracted Stated Job Value: ¤274,163.00
Job Description: Single Family Residence
Type: CN

Contractor

BLUE WATER HOMES INC
Status Location Address State License Number Phone
ACTIVE

4881 PALM COAST PARKWAY NW UNIT 1

PALM COAST, FL 32137

CBC1258679 (Exp: 08/31/2026) 386-445-3405

Sub Contractors

JACK DOUGLAS LANIER
Status Location Address State License Number Phone Fax
ACTIVE

485 COMMERCE WAY

LONGWOOD , FL 32750

CCC058022 (Exp: 08/31/2026) (321)441-2300 (321)441-2313
JEFFREY TROY SABAKA
Status Location Address State License Number Phone Fax
ACTIVE

2191 DEERWOOD ACRES DR

ST AUGUSTINE, FL 32084

CFC1427439 (Exp: 08/31/2026) 904-838-2218 904-819-0965
BRETT CHRISTIAN GIBSON
Status Location Address State License Number Phone
ACTIVE

250 SEGOVIA RD

ST AUGUSTINE, FL 32086

CAC1818423 (Exp: 08/31/2026) 904-229-8131
WILLIAM FRANK DUDLEY JR.
Status Location Address State License Number Phone
ACTIVE

P.O. BOX 978

Bunnell, FL 32110

EC0003177 (Exp: 08/31/2026) (386)437-3068

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 12/12/2023 FINAL APPROVED JWALKER
Note: 12/8/2023 - PREVIOUS INSPECTION NOTES 1. Hose bib missing shear screw 2. Liquid tight @ ODU can not be in areas subjuct to physical damage 3. Cat 5 by metermain needs to be sealed @ stucco 4. Garage door lights do not work Stopped inspection in garage did not check Inside, E-cals, or breaker sizes
BLD - BUILDING FINAL 12/08/2023 Disapproved - NO FEE MKRASKI
Note: 1. Hose bib missing shear screw 2. Liquid tight @ ODU can not be in areas subjuct to physical damage 3. Cat 5 by metermain needs to be sealed @ stucco 4. Garage door lights do not work Stopped inspection in garage did not check Inside, E-cals, or breaker sizes
U -UTILITY RESIDENTIAL FINAL 12/08/2023 APPROVED - AS NOTED LFITZGERALD
Note: Inspector Notes from Inspection 9035 realign check valves on water meter assembly so pet cocks canbe accessible/maintain ball vlave handle on top-pic to me when corrected no irrigation-no cross connection
ROW FIELD SURVEY /GRADING CERTIFICATION 12/07/2023 APPROVED PFLANAGAN
Note: CORRECTION MADE WITH THE GRADE ON RIGHT SIDE OF HOUSE At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved --------------------------------------------------------------------------- 12/5/2023 - PREVIOUS INSPECTION NOTES THE FIELD DOESN'T REFLECT WHATS IN THE FIELD THE DRAINAGE PATTERN ON THE RIGHT IS IMPACTING THE ADJACENT LOT TO THE RIGHT NEED TO FIX SO YOUR WATER WILL NOT IMPACT THEM. THE FINAL SHOWS A SWALE ON THE INSIDE THE PROPERTY LINE BUT NO SWALE.
ROW - STORMWATER FINAL 12/07/2023 APPROVED PFLANAGAN
Note: At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved
ROW - FINAL APRON (AFTER POUR) 12/07/2023 APPROVED PFLANAGAN
Note: At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved
U-CROSS CONNECTION 12/06/2023 APPROVED - AS NOTED LFITZGERALD
Note: no irrigation-no cross connection
ROW- FINAL SURVEY/GRADING CERTIFICATION 12/05/2023 APPROVED PFLANAGAN
Note: At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved. ------------------------------------------------------------------------ 11/28/2023 - PREVIOUS INSPECTION NOTES 1) THE ELEVATION IN THE MIDDLE OF THE BACKYARD CAN'T READ IT NEED THAT ELEVATION TO SEE IF THE WATER IS NOT RUNNING TO THE BACK PROPERTY LINE Sec 300.02 B1 If the survey is incomplete, unclear, does not adequately show the drainage patterns. 2) THE DRAINAGE ON THE RIGHT SIDE DOESN'T HAVE POSITVIE FALL EVERY 20' THE DRAINAGE IS UP AND DOWN Sec.300.01 (4,5,6) The tolerance along side lot lines is no more than 20 feet, with positive fall on each side. Positive fall is considered to be 0.10 feet in 20 feet. 3) ALL ELEVATIONS ON THE RIGHT OF WAY NEED TO BE GREATER OR EQUAL TO THE CENTERLINE OF THE ROAD ELEVATIONS Drawing 300.D,The front property line/right away elevation are to be equal to or greater than the centerline of the road elevation.
ROW FIELD SURVEY /GRADING CERTIFICATION 12/05/2023 Disapproved - NO FEE PFLANAGAN
Note: THE FIELD DOESN'T REFLECT WHATS IN THE FIELD THE DRAINAGE PATTERN ON THE RIGHT IS IMPACTING THE ADJACENT LOT TO THE RIGHT NEED TO FIX SO YOUR WATER WILL NOT IMPACT THEM. THE FINAL SHOWS A SWALE ON THE INSIDE THE PROPERTY LINE BUT NO SWALE.
ROW- FINAL SURVEY/GRADING CERTIFICATION 11/28/2023 Disapproved - NO FEE PFLANAGAN
Note: 1) THE ELEVATION IN THE MIDDLE OF THE BACKYARD CAN'T READ IT NEED THAT ELEVATION TO SEE IF THE WATER IS NOT RUNNING TO THE BACK PROPERTY LINE Sec 300.02 B1 If the survey is incomplete, unclear, does not adequately show the drainage patterns. 2) THE DRAINAGE ON THE RIGHT SIDE DOESN'T HAVE POSITVIE FALL EVERY 20' THE DRAINAGE IS UP AND DOWN Sec.300.01 (4,5,6) The tolerance along side lot lines is no more than 20 feet, with positive fall on each side. Positive fall is considered to be 0.10 feet in 20 feet. 3) ALL ELEVATIONS ON THE RIGHT OF WAY NEED TO BE GREATER OR EQUAL TO THE CENTERLINE OF THE ROAD ELEVATIONS Drawing 300.D,The front property line/right away elevation are to be equal to or greater than the centerline of the road elevation.
ROW- PRE-APRON (PRE-POUR) 10/18/2023 APPROVED PFLANAGAN
Note: IT'S YOUR RESPONSIBILITY TO CHECK THE CULVERT ELEVATIONS BEFORE POURING CONCRETE ALL CONCRETE NEEDS TO BE A MINIMUM OF 3000PSI WITH FIBER OR WITH METAL MESH IN THE CONCRETE TO MEET ALL CITY'S STANDARTS At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved. ----------------------------------------------------------------------------------------- 10/16/2023 - PREVIOUS INSPECTION NOTES 1) THERE ARE AREAS IN POURING AREA THAT DONT GIVE YOU THE MINIMUM AMOUNT OF CONCRETE Sec.900.04A Driveway thickness on the right-of-way shall be either six inches (6") on firmly compacted subgrade of clean granular material or five inches (5") on three inches (3") of limerock or shell base. Sec 400.02 Sidewalks constructed within the City of Palm Coast shall be constructed with 3000 psi concrete and contain fiber or wire mesh. Sidewalk shall be a minimum of 4" thick concrete. Sidewalks at driveway/turnout crossings shall be a minimum of 6" thick concrete. 2) THERE ARE FORM BOARDS THAT ARE MISSING NEED TO HAVE PRE POUR READY AT THE TIME OF INSPECTION Sec. 900.09f Permittee shall be charged an additional fee for each re-inspection required should permittee call for an inspection and NOT be prepared for the requested inspection. ------------------------------------------------------------------------------------------------ 10/12/2023 - PREVIOUS INSPECTION NOTES
ROW- PRE-APRON (PRE-POUR) 10/16/2023 Disapproved -FEE REQUIRED PFLANAGAN
Note: 1) THERE ARE AREAS IN POURING AREA THAT DONT GIVE YOU THE MINIMUM AMOUNT OF CONCRETE Sec.900.04A Driveway thickness on the right-of-way shall be either six inches (6") on firmly compacted subgrade of clean granular material or five inches (5") on three inches (3") of limerock or shell base. Sec 400.02 Sidewalks constructed within the City of Palm Coast shall be constructed with 3000 psi concrete and contain fiber or wire mesh. Sidewalk shall be a minimum of 4" thick concrete. Sidewalks at driveway/turnout crossings shall be a minimum of 6" thick concrete. 2) THERE ARE FORM BOARDS THAT ARE MISSING NEED TO HAVE PRE POUR READY AT THE TIME OF INSPECTION Sec. 900.09f Permittee shall be charged an additional fee for each re-inspection required should permittee call for an inspection and NOT be prepared for the requested inspection. ------------------------------------------------------------------------------------------------ 10/12/2023 - PREVIOUS INSPECTION NOTES
ROW- PRE-APRON (PRE-POUR) 10/12/2023 CANCELLED BY APPLICANT PFLANAGAN
ROW- PRE-APRON (PRE-POUR) 10/09/2023 CANCELLED BY APPLICANT WEB
ELECTRIC - EARLY POWER 09/29/2023 APPROVED - AS NOTED MKRASKI
Note: Emailed FPL @ 11 AM
TUB SET 09/13/2023 APPROVED - AS NOTED KSANDOE
Note: 9/12/2023 - PREVIOUS INSPECTION NOTES 9/11/2023 - PREVIOUS INSPECTION NOTES R319.1 Address identification. Buildings shall be provided with approved address identification. The address identification shall be legible and placed in a position that is visible from the street or road fronting the property.SEE PRIVIOUS NOTES
WINDOW NAILING 09/13/2023 APPROVED KSANDOE
Note: New inspection due to canceled inspection Window is to be tempered over master tub
TUB SET 09/12/2023 Disapproved -FEE REQUIRED MGIBSON
Note: 9/11/2023 - PREVIOUS INSPECTION NOTES R319.1 Address identification. Buildings shall be provided with approved address identification. The address identification shall be legible and placed in a position that is visible from the street or road fronting the property.SEE PRIVIOUS NOTES
TUB SET 09/11/2023 Disapproved -FEE REQUIRED KSANDOE
Note: R319.1 Address identification. Buildings shall be provided with approved address identification. The address identification shall be legible and placed in a position that is visible from the street or road fronting the property.
WINDOW NAILING 08/17/2023 CANCELLED BY APPLICANT WEB
Note: Window is to be tempered over master tub
U - SEWER TIE IN 08/17/2023 APPROVED - AS NOTED MGIBSON
Note: THIS WAS A VIRTUAL INSPECTION
PEP TANK INSTALLATION REQUEST 07/28/2023 APPROVED CBOWERMASTER
INSULATION 07/28/2023 APPROVED JWALKER
Note: Inspector Notes from Inspection 2420 7/25/23 1. Added tub set inspection 2. Added window nailing for tempered glass in master shower 3. Nail plate required at top plate for range hood 7/17/2023 - PREVIOUS INSPECTION NOTES 1. All exhaust fan ducts are required to be supported every 4' 2. proper nail plates are required for range hood vent @ top plate 3. Product approval sheet does mot match what is installed 4. Master tub fixed window is required to be tempered 5. Spare bathrrom suppply lineeds to need to be sealed @ slab 6. Stickers have been removed from some windows and doors 7. Mullbar brackets missing on some double windows check all 8. Will add tub set inspection for master tub if not installed at re-inspection
ALL ROUGH 07/25/2023 APPROVED - AS NOTED MKRASKI
Note: 7/25/23 1. Added tub set inspection 2. Added window nailing for tempered glass in master shower 3. Nail plate required at top plate for range hood 7/17/2023 - PREVIOUS INSPECTION NOTES 1. All exhaust fan ducts are required to be supported every 4' 2. proper nail plates are required for range hood vent @ top plate 3. Product approval sheet does mot match what is installed 4. Master tub fixed window is required to be tempered 5. Spare bathrrom suppply lineeds to need to be sealed @ slab 6. Stickers have been removed from some windows and doors 7. Mullbar brackets missing on some double windows check all 8. Will add tub set inspection for master tub if not installed at re-inspection
LATH/BRICK/ WATER BARRIER 07/20/2023 APPROVED MKRASKI
ALL ROUGH 07/17/2023 Disapproved -FEE REQUIRED MKRASKI
Note: 1. All exhaust fan ducts are required to be supported every 4' 2. proper nail plates are required for range hood vent @ top plate 3. Product approval sheet does mot match what is installed 4. Master tub fixed window is required to be tempered 5. Spare bathrrom suppply lineeds to need to be sealed @ slab 6. Stickers have been removed from some windows and doors 7. Mullbar brackets missing on some double windows check all 8. Will add tub set inspection for master tub if not installed at re-inspection
ROOF SHEATHING / BRACES/TIES/DOWN CELL 07/12/2023 APPROVED MKRASKI
ROOF SHEATHING / BRACES/TIES/DOWN CELL 06/26/2023 Disapproved - NO FEE RSIMS
Note: 6/26/23: Met with Superintendent. Previously listed items resolved. Truss Engineering complete - Disapproved Revision will need to be submitted to & approved by the City for the Trusses that do not meet the configuration as shown on the MiTek documents. 1). Truss T20 bottom cord repair does not meet MiTek requirements. 2). Truss T14 - missing bracing & configuration does not match MiTek. 3). Truss T28 - missing bracing & configuration does not match MiTek. 4). Truss T29 missing web bracing per MiTek. 5). Truss T30 - Configuration does not match MiTek. 6). Truss T31 - Configuration does not match MiTek & bracing/engineering is installed on the wrong web. 6/21/2023 - PREVIOUS INSPECTION NOTES 6-21-23 1. Still need double PT 2x4s at bearing walls to CMU connections per plans (specified) 2. Still missing simpson MTS18s (check all) 3. still missing CS16 at top of post under girder at garage wall per note E 4. still missing .5x10 inch anchors at bottom plates on interior bearing wall per frame to block connection detail 5. Continuous load path… R301,2.1 overframing not tied to structural members beneath (check All) Inspection stopped 6/20/2023 - PREVIOUS INSPECTION NOTES 6-20-23 1. Still need double PT 2x4s at bearing walls to CMU connections 2. missing simpson MTS18s (check all) 3. missing 4x4 PT post or 202x4s under girder at garage wall per note E 4. Missing missing ABU44 at base of missing post under girder at garage wall per note E 5. missing CS16 at top of post under girder at garage wall per note E 6. still missing .5x10 inch anchors at bottom plates on interior bearing wall per frame to block connection detail 7. Continuous load path… R301,2.1 overframing not tied to structural members beneath (check All) Inspection stopped 6/14/2023 - PREVIOUS INSPECTION NOTES 6/8/2023 - PREVIOUS INSPECTION NOTES 1. Load bearing wall to CMU required to have double P.T, 2x4s 2. Load bearing wall to CMU requires anchors max of 2' 3. All thread is loose 4. Load bearing wall requires anchors max 32'' Stopped inspection, roof sheathing passed
ROOF SHEATHING / BRACES/TIES/DOWN CELL 06/21/2023 Disapproved -FEE REQUIRED LMILLER
Note: 6-21-23 1. Still need double PT 2x4s at bearing walls to CMU connections per plans (specified) 2. Still missing simpson MTS18s (check all) 3. still missing CS16 at top of post under girder at garage wall per note E 4. still missing .5x10 inch anchors at bottom plates on interior bearing wall per frame to block connection detail 5. Continuous load path… R301,2.1 overframing not tied to structural members beneath (check All) Inspection stopped 6/20/2023 - PREVIOUS INSPECTION NOTES 6-20-23 1. Still need double PT 2x4s at bearing walls to CMU connections 2. missing simpson MTS18s (check all) 3. missing 4x4 PT post or 202x4s under girder at garage wall per note E 4. Missing missing ABU44 at base of missing post under girder at garage wall per note E 5. missing CS16 at top of post under girder at garage wall per note E 6. still missing .5x10 inch anchors at bottom plates on interior bearing wall per frame to block connection detail 7. Continuous load path… R301,2.1 overframing not tied to structural members beneath (check All) Inspection stopped 6/14/2023 - PREVIOUS INSPECTION NOTES 6/8/2023 - PREVIOUS INSPECTION NOTES 1. Load bearing wall to CMU required to have double P.T, 2x4s 2. Load bearing wall to CMU requires anchors max of 2' 3. All thread is loose 4. Load bearing wall requires anchors max 32'' Stopped inspection, roof sheathing passed
ROOF SHEATHING / BRACES/TIES/DOWN CELL 06/20/2023 Disapproved -FEE REQUIRED LMILLER
Note: 6-20-23 1. Still need double PT 2x4s at bearing walls to CMU connections 2. missing simpson MTS18s (check all) 3. missing 4x4 PT post or 202x4s under girder at garage wall per note E 4. Missing missing ABU44 at base of missing post under girder at garage wall per note E 5. missing CS16 at top of post under girder at garage wall per note E 6. still missing .5x10 inch anchors at bottom plates on interior bearing wall per frame to block connection detail 7. Continuous load path… R301,2.1 overframing not tied to structural members beneath (check All) Inspection stopped 6/14/2023 - PREVIOUS INSPECTION NOTES 6/8/2023 - PREVIOUS INSPECTION NOTES 1. Load bearing wall to CMU required to have double P.T, 2x4s 2. Load bearing wall to CMU requires anchors max of 2' 3. All thread is loose 4. Load bearing wall requires anchors max 32'' Stopped inspection, roof sheathing passed
ROOF SHEATHING / BRACES/TIES/DOWN CELL 06/14/2023 CANCELLED BY APPLICANT MKRASKI
Note: 6/8/2023 - PREVIOUS INSPECTION NOTES 1. Load bearing wall to CMU required to have double P.T, 2x4s 2. Load bearing wall to CMU requires anchors max of 2' 3. All thread is loose 4. Load bearing wall requires anchors max 32'' Stopped inspection, roof sheathing passed
WALL SHEATHING 06/14/2023 APPROVED MKRASKI
ROOF SHEATHING / BRACES/TIES/DOWN CELL 06/08/2023 Disapproved - NO FEE MKRASKI
Note: 1. Load bearing wall to CMU required to have double P.T, 2x4s 2. Load bearing wall to CMU requires anchors max of 2' 3. All thread is loose 4. Load bearing wall requires anchors max 32'' Stopped inspection, roof sheathing passed
ROOF VALLEY & METAL 06/08/2023 APPROVED MKRASKI
TIE BEAM / LINTEL 05/05/2023 APPROVED MKRASKI
FOUND SURVEY APPROVED (OFFICE) 05/03/2023 APPROVED TBAKER
MONOLITHIC SLAB 04/11/2023 APPROVED MKRASKI
MONOLITHIC SLAB 04/10/2023 Disapproved -FEE REQUIRED MKRASKI
Note: 4/10/23 1. Address not visible from road per FBC 319.1, number must be atleast 4'' tall 2. Footing full of water and wash outs 4/6/2023 - PREVIOUS INSPECTION NOTES 1. Not ready 2. Address not visible from road per FBC 319.1
MONOLITHIC SLAB 04/06/2023 Disapproved -FEE REQUIRED MKRASKI
Note: 1. Not ready 2. Address not visible from road per FBC 319.1
PLUMBING 1ST ROUGH UNDERGROUND 03/28/2023 APPROVED MGIBSON
GRAVITY SEWER TEST 03/28/2023 APPROVED MGIBSON
WATER METER INSTALLATION REQUEST 03/01/2023 APPROVED TSCHWEERS

Review History

Department Status Date In Date Out
BLD COMPLETE 07/18/2023 07/21/2023
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
BLD COMPLETE 06/26/2023 06/29/2023
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
BLD COMPLETE 06/09/2023 06/12/2023
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
MECH COMPLETE 06/05/2023 06/05/2023
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
BLD COMPLETE 06/02/2023 06/05/2023
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
MECH HOLD 06/02/2023 06/05/2023
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Provide duct layout signed by the AC contractor
ENGIN1 COMPLETE 05/03/2023 05/03/2023
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON COMPLETE 05/03/2023 05/03/2023
Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM
BLD COMPLETE 02/10/2023 02/15/2023
Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM
CUSVC COMPLETE 02/10/2023 02/13/2023
Note: Released By: LISA ASBILL - - lasbill@palmcoastgov.com
ELEC COMPLETE 02/10/2023 02/13/2023
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ENGIN1 COMPLETE 02/10/2023 02/10/2023
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
LOCATE COMPLETE 02/10/2023 02/13/2023
Note: Released By: TONI CHURCHILL - -
MECH COMPLETE 02/10/2023 02/13/2023
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
SW1 COMPLETE 02/10/2023 02/21/2023
Note: Released By: ROBERT GROSS - (386)986-4769 - RGROSS@PALMCOASTGOV.COM
ZON COMPLETE 02/10/2023 02/13/2023
Note: Released By: MICHELLE RAMOS - - MRAMOS@PALMCOASTGOV.COM
SWALE COMPLETE 02/10/2023 05/15/2023
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
SW ENG REINSPECTION 30 ¤30.00 10/23/2023
REINSPECTION RESIDENTIAL ¤40.00 09/13/2023
REINSPECTION RESIDENTIAL ¤40.00 09/13/2023
REINSPECTION RESIDENTIAL ¤40.00 09/13/2023
REINSPECTION RESIDENTIAL ¤40.00 06/21/2023
REINSPECTION RESIDENTIAL ¤40.00 06/21/2023
PLAN REVIEW - REVISION ¤32.50 06/21/2023
REINSPECTION RESIDENTIAL ¤40.00 06/21/2023
REINSPECTION RESIDENTIAL ¤40.00 06/21/2023
WATER- TURN ON ¤25.00 02/22/2023
ADJUSTMENT 50% (¤500.38) 02/22/2023
ADMINISTRATIVE RESIDENTIAL ¤30.00 02/22/2023
INSPECTION - RESIDENTIAL ¤756.25 02/22/2023
PLAN REVIEW - RESIDENTIAL ¤214.50 02/22/2023
SW ENG - REVIEW 20 ¤20.00 02/22/2023
SW ENG RES REVIEW 200 ¤200.00 02/22/2023
TRANS IMPACT FEE ADMIN ¤54.36 02/22/2023
TRANS IMPACT FEE ADMIN (¤54.36) 02/22/2023
SEWER CREDIT (¤1,147.00) 02/22/2023
SEWER INSPECTION ¤25.00 02/22/2023
SEWER CAPITAL FACILITY ¤5,344.82 02/22/2023
WATER CAPITAL FACILITY FEE ¤3,923.88 02/22/2023
SITE PLAN 30 ¤30.00 02/22/2023
CONNECTION FEES ¤1,166.26 02/22/2023
FIRE IMPACT FEE ADMIN ¤12.62 02/22/2023
FIRE IMPACT FEE ADMIN (¤12.62) 02/22/2023
FC IMPACT FEE EMS ¤62.00 02/22/2023
IMPACT FEE FIRE ¤420.52 02/22/2023
FC IMPACT FEE LAW ENFORCEMENT ¤218.00 02/22/2023
FC IMPACT FEE LIBRARY ¤268.00 02/22/2023
IMPACT FEE PARKS ¤1,769.15 02/22/2023
IMPACT FEE SCHOOL ¤5,450.00 02/22/2023
IMPACT FEE TRANSPORTATION ¤1,812.00 02/22/2023
WATER -IRRIGATION INSPECTION ¤25.00 02/22/2023
PARKS IMPACT FEE ADMIN ¤53.07 02/22/2023
PARKS IMPACT FEE ADMIN (¤53.07) 02/22/2023
SURCHARGE FS 533.721 ¤3.24 02/22/2023
SURCHARGE - FS 468.631 ¤4.86 02/22/2023
SW ENG - FOUNDATION SURVEY ¤20.00 02/22/2023
SW ENG INSPECTION 80 ¤80.00 02/22/2023
SW ENG PRE APRON ¤30.00 02/22/2023
Fees Total Due: ¤0.00 Total Paid: ¤20,593.60