Permit #2023020692
Permit Details
Status: COED
| Parcel Id: 07-11-31-7028-00120-0340 |
| CONDITIONED SPACE: 1448 sqft |
| GARAGE: 418 sqft |
| OPENED PORCH (WITH ROOF) : 156 sqft |
| Total Square Footage: 2022 sqft |
| Block: 00120 |
| Subdivision: 2199 - SECTION 28-WYNNFIELD |
| Job Phone: 386-338-1859 |
| Location Address: 33 PONTIAC LN |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 03/14/2023 |
| NOC: RECORDED |
| Applicant name: SOPHAN KES |
| Owner: MORSE JEFFERY |
|
Address 95 FLYING CLOUD DR OROVILLE, CA 95965 |
| Lot: 0340 |
| Contracted Stated Job Value: ¤250,000.00 |
| Job Description: SINGLE FAMILY RESIDENCE |
| Type: CN |
Contractor
KES CONSTRUCTION, INC
| Status | Location Address | State License Number |
| ACTIVE |
42 OAKLEAF WAY PALM COAST, FL 32137 |
CBC1264797 (Exp: 08/31/2026) |
Sub Contractors
ROBERT JAMES BARROW JR
| Status | Location Address | Mailing Address | State License Number | Phone |
| ACTIVE |
2323 N STATE ST BUNNELL, FL 32110 |
UNIT 126 BUNNELL, FL 32110 |
CAC1817890 (Exp: 08/31/2026) | 386-627-5500 |
GIOVANNI DISARRO
| Status | Location Address | State License Number |
| INACTIVE |
107 BURROUGHS DRIVE PALM COAST, FL 32137 |
CFC1430761 (Exp: 08/31/2026) |
CHRISTOPHER I HALL
| Status | Location Address | State License Number | Phone |
| ACTIVE |
60 COOPER LANE PALM COAST, FL 32137 |
EC13008029 (Exp: 08/31/2028) | 386-225-1937 |
PEDRO DANIEL CHINCHILLA
| Status | Location Address | State License Number | Phone |
| ACTIVE |
324 COVENT GARDENS PL DELTONA, FL 32725 |
CCC1333997 (Exp: 08/31/2026) | 386-679-6228 |
Inspection History
| Type | Request Date | Result | Inspector |
| BLD - BUILDING FINAL | 10/25/2023 | FINAL APPROVED | KSANDOE |
| U-CROSS CONNECTION | 10/25/2023 | APPROVED - AS NOTED | LFITZGERALD |
| Note: well irrigation-no cross connection | |||
| ROW - STORMWATER FINAL | 10/25/2023 | APPROVED - AS NOTED | FSLADISH |
| Note: 10/25/23 CORRECTIONS MADE LOOKED GOOD AT THE TIME OF THIS INSPECTION.. At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved. | |||
| U -UTILITY RESIDENTIAL FINAL | 10/25/2023 | Disapproved -FEE REQUIRED | LFITZGERALD |
| Note: lower sewer clean out/install correct pep circuit breaker-stand alone 20 amp-no test/arch | |||
| U -UTILITY RESIDENTIAL FINAL | 10/25/2023 | FINAL APPROVED | LFITZGERALD |
| Note: 10/25/2023 - PREVIOUS INSPECTION NOTES lower sewer clean out/install correct pep circuit breaker-stand alone 20 amp-no test/arch | |||
| ROW FIELD SURVEY /GRADING CERTIFICATION | 10/24/2023 | APPROVED | GBERTOLA |
| Note: 10/24/23= CORRECTION WERE MADE AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. | |||
| ROW - FINAL APRON (AFTER POUR) | 10/24/2023 | APPROVED | GBERTOLA |
| Note: AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. THIS INCLUDES BUT IS NOT LIMITED TO THE CULVERT PIPE ELEVATION FROM THE TIME OF THE INSPECTION APPROVAL TO THE CONCRETE POUR. | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 10/23/2023 | APPROVED | GBERTOLA |
| Note: 10/23/23= AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. THIS INCLUDES BUT IS NOT LIMITED TO THE CULVERT PIPE ELEVATION FROM THE TIME OF THE INSPECTION APPROVAL TO THE CONCRETE POUR. | |||
| ROW FIELD SURVEY /GRADING CERTIFICATION | 10/23/2023 | Disapproved - NO FEE | GBERTOLA |
| Note: SWALE: FINISH GRADE TO BE 2 INCHES BELOW THE EDGE OF THE PAVEMENT BEFORE SOD IS LAID, DRAWING 300.D CITY OF PALM COAST TECHNICAL MANUAL.THE STORMWATER FLOW INTO THE SWALES IS BLOCKED BY THE SOD, WHICH IS HIGHER THAN THE ROAD'S EDGE. IT IS NECESSARY TO CREATE A HIGH POINT IN THE CORNER TO SEPARATE THE WATER FLOWING FROM RIGHT TO LEFT. THE SPOT IS LOWER ON THE SWALE FROM THE CORNER TOWARDS TO THE DRIVEWAY, LEFT PAINTED WITH WHITE SPRAY PAINT | |||
| U - SEWER TIE IN | 10/03/2023 | APPROVED | MGIBSON |
| Note: Inspector Notes from Inspection 2060 NEED PORTABLE RESTROOM BEFORE SCHEDUALING NEXT INSPECTION | |||
| GRAVITY SEWER TEST | 10/03/2023 | APPROVED | MGIBSON |
| Note: Inspector Notes from Inspection 2060 NEED PORTABLE RESTROOM BEFORE SCHEDUALING NEXT INSPECTION | |||
| ELECTRIC - EARLY POWER | 09/29/2023 | APPROVED - AS NOTED | KSANDOE |
| Note: Emailed FPL @ 1421. Release Power 9/28/2023 - PREVIOUS INSPECTION NOTES House is locked. Inspector Notes from Inspection 2170 Emailed FPL @ 1414. Release Power | |||
| ELECTRIC - EARLY POWER | 09/28/2023 | Disapproved - NO FEE | KSANDOE |
| Note: House is locked. Inspector Notes from Inspection 2170 Emailed FPL @ 1414. Release Power | |||
| ROW- PRE-APRON (PRE-POUR) | 09/19/2023 | APPROVED - AS NOTED | FSLADISH |
| Note: 09/19/23 CORRECTIONS MADE. READY TO POUR AT TIME OF THIS INSPECTION. At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved. This includes but is not limited to, the Culvert Pipe Elevation from the time of the inspection approval to the concrete pour. AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS BEFORE POURING. MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL 9/18/2023 - PREVIOUS INSPECTION NOTES 09/18/23 YOU NEED TO HAVE A MINIMUM OF 5" OF CONCRETE OVER THE CULVERT PIPE. SEE PHOTS FOR REFERENCE. PIPE WAS GOOD AT THE TIME OF THIS INSPECTION. | |||
| ROW- PRE-APRON (PRE-POUR) | 09/18/2023 | Disapproved -FEE REQUIRED | FSLADISH |
| Note: 09/18/23 YOU NEED TO HAVE A MINIMUM OF 5" OF CONCRETE OVER THE CULVERT PIPE. SEE PHOTS FOR REFERENCE. PIPE WAS GOOD AT THE TIME OF THIS INSPECTION. | |||
| PEP TANK INSTALLATION REQUEST | 09/06/2023 | APPROVED | CBOWERMASTER |
| INSULATION | 08/14/2023 | APPROVED | KSANDOE |
| ALL ROUGH | 08/08/2023 | APPROVED | TSTAUFFACHER |
| Note: 8/4/2023 - PREVIOUS INSPECTION NOTES 8/4/23: INSPECTION STOPPED! Need address more prominently displayed as per FBC 319.1/501.2 ** Incomplete plans in permit box for inspection. (Also, no energy calcs for duct layout, etc.) 8/3/2023 - PREVIOUS INSPECTION NOTES Product approval sheet revision required to show CWS windows as installed. Inspected windows and doors only | |||
| ALL ROUGH | 08/04/2023 | Disapproved -FEE REQUIRED | RSIMS |
| Note: 8/4/23: INSPECTION STOPPED! Need address more prominently displayed as per FBC 319.1/501.2 ** Incomplete plans in permit box for inspection. (Also, no energy calcs for duct layout, etc.) 8/3/2023 - PREVIOUS INSPECTION NOTES Product approval sheet revision required to show CWS windows as installed. Inspected windows and doors only | |||
| LATH/BRICK/ WATER BARRIER | 08/04/2023 | APPROVED | RSIMS |
| ALL ROUGH | 08/03/2023 | CANCELLED BY APPLICANT | WEB |
| ALL ROUGH | 08/03/2023 | PARTIALLY APPROVED | KSANDOE |
| Note: Product approval sheet revision required to show CWS windows as installed. Inspected windows and doors only | |||
| WALL SHEATHING | 08/02/2023 | APPROVED | KSANDOE |
| ELECTRIC TEMP POLE | 08/02/2023 | APPROVED - AS NOTED | KSANDOE |
| Note: Emailed FPL @ 1414. Release Power | |||
| ELECTRIC - EARLY POWER | 08/01/2023 | Disapproved - NO FEE | KSANDOE |
| Note: Wrong inspection requested. Not ready for early power | |||
| ROOF VALLEY & METAL | 06/26/2023 | APPROVED | KSANDOE |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 06/20/2023 | APPROVED | KSANDOE |
| Note: 6/13/2023 - PREVIOUS INSPECTION NOTES Multiple trusses missing bracing. Marked on plans Inspection stopped. Job box hidden behind dumpster. Address needs to be prominently displayed | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 06/13/2023 | Disapproved - NO FEE | KSANDOE |
| Note: Multiple trusses missing bracing. Marked on plans Inspection stopped. Job box hidden behind dumpster. Address needs to be prominently displayed | |||
| TIE BEAM / LINTEL | 05/24/2023 | APPROVED | KSANDOE |
| FOUND SURVEY APPROVED (OFFICE) | 05/04/2023 | APPROVED | TBAKER |
| MONOLITHIC SLAB | 04/24/2023 | APPROVED | KSANDOE |
| Note: 4/21/2023 - PREVIOUS INSPECTION NOTES 4/19/2023 - PREVIOUS INSPECTION NOTES Plans call for 4" slab. Multiple areas measuring less. Entire slab needs to be tamped down | |||
| MONOLITHIC SLAB | 04/21/2023 | CANCELLED BY APPLICANT | KSANDOE |
| Note: 4/19/2023 - PREVIOUS INSPECTION NOTES Plans call for 4" slab. Multiple areas measuring less. Entire slab needs to be tamped down | |||
| MONOLITHIC SLAB | 04/19/2023 | Disapproved - NO FEE | KSANDOE |
| Note: Plans call for 4" slab. Multiple areas measuring less. Entire slab needs to be tamped down | |||
| PLUMBING 1ST ROUGH UNDERGROUND | 04/17/2023 | APPROVED - AS NOTED | MGIBSON |
| Note: NEED PORTABLE RESTROOM BEFORE SCHEDUALING NEXT INSPECTION | |||
| WATER METER INSTALLATION REQUEST | 04/10/2023 | APPROVED | CSTONE |
Review History
| Department | Status | Date In | Date Out |
| BLD | COMPLETE | 08/07/2023 | 08/07/2023 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 05/03/2023 | 05/04/2023 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 05/03/2023 | 05/04/2023 |
| Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 03/09/2023 | 03/10/2023 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 03/09/2023 | 03/10/2023 |
| Note: Released By: MICHELLE RAMOS - - MRAMOS@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 03/09/2023 | 03/13/2023 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ELEC | COMPLETE | 02/24/2023 | 02/24/2023 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| SWALE | COMPLETE | 02/15/2023 | 05/18/2023 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| BLD | HOLD | 02/14/2023 | 02/21/2023 |
| Note: Held By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM All comments below per the 2020 Florida Building Code PLAN REVIEW COMMENTS: 1. Provide Product Approval for Front Entry Door. | |||
| CUSVC | COMPLETE | 02/14/2023 | 02/20/2023 |
| Note: Released By: LISA ASBILL - - lasbill@palmcoastgov.com | |||
| ELEC | HOLD | 02/14/2023 | 02/21/2023 |
| Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM Submit electric load calcs | |||
| ENGIN1 | COMPLETE | 02/14/2023 | 02/15/2023 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| LOCATE | COMPLETE | 02/14/2023 | 02/17/2023 |
| Note: Released By: TONI CHURCHILL - - | |||
| MECH | HOLD | 02/14/2023 | 02/15/2023 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM 1. Energy Calcs need to be signed by the owner/ owner agent below the preparer per R103.1.1.2 FBC Energy Conservation 2020 7Th edition 2. Duct layout needs to be signed by the AC contractor per 107.1 FBC Residential 2020 7th Edition 3. EPL Card needs to be signed by the builder per 107.1 FBC Residential 2020 7Th edition WHEN UPLOADING CORRECTIONS UPLOAD AS ONE FILE (ENERGY CALCS) | |||
| SW1 | COMPLETE | 02/14/2023 | 02/28/2023 |
| Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM | |||
| ZON | HOLD | 02/14/2023 | 02/15/2023 |
| Note: Held By: MICHELLE RAMOS - - MRAMOS@PALMCOASTGOV.COM Color Material Sheet please specify the stucco/siding color. |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION RESIDENTIAL | ¤40.00 | 10/25/2023 |
| REINSPECTION FEE | ¤40.00 | 10/25/2023 |
| SW ENG REINSPECTION 30 | ¤30.00 | 10/25/2023 |
| SW ENG - REVIEW 20 | ¤20.00 | 03/14/2023 |
| SW ENG RES REVIEW 200 | ¤200.00 | 03/14/2023 |
| TRANS IMPACT FEE ADMIN | ¤54.36 | 03/14/2023 |
| TRANS IMPACT FEE ADMIN | (¤54.36) | 03/14/2023 |
| SEWER CREDIT | (¤1,300.00) | 03/14/2023 |
| SEWER INSPECTION | ¤25.00 | 03/14/2023 |
| SEWER CAPITAL FACILITY | ¤5,344.82 | 03/14/2023 |
| WATER CAPITAL FACILITY FEE | ¤3,923.88 | 03/14/2023 |
| SITE PLAN 30 | ¤30.00 | 03/14/2023 |
| SURCHARGE FS 533.721 | ¤2.99 | 03/14/2023 |
| SURCHARGE - FS 468.631 | ¤4.48 | 03/14/2023 |
| SW ENG - FOUNDATION SURVEY | ¤20.00 | 03/14/2023 |
| SW ENG INSPECTION 80 | ¤80.00 | 03/14/2023 |
| SW ENG PRE APRON | ¤30.00 | 03/14/2023 |
| WATER- TURN ON | ¤25.00 | 03/14/2023 |
| ADJUSTMENT 50% | (¤456.25) | 03/14/2023 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 03/14/2023 |
| INSPECTION - RESIDENTIAL | ¤687.50 | 03/14/2023 |
| PLAN REVIEW - RESIDENTIAL | ¤195.00 | 03/14/2023 |
| CONNECTION FEES | ¤1,166.26 | 03/14/2023 |
| FIRE IMPACT FEE ADMIN | ¤12.62 | 03/14/2023 |
| FC IMPACT FEE EMS | ¤62.00 | 03/14/2023 |
| IMPACT FEE FIRE | ¤420.52 | 03/14/2023 |
| FC IMPACT FEE LAW ENFORCEMENT | ¤218.00 | 03/14/2023 |
| FC IMPACT FEE LIBRARY | ¤268.00 | 03/14/2023 |
| IMPACT FEE PARKS | ¤1,769.15 | 03/14/2023 |
| IMPACT FEE SCHOOL | ¤5,450.00 | 03/14/2023 |
| IMPACT FEE TRANSPORTATION | ¤1,812.00 | 03/14/2023 |
| WATER -IRRIGATION INSPECTION | ¤25.00 | 03/14/2023 |
| PARKS IMPACT FEE ADMIN | ¤53.07 | 03/14/2023 |
| PARKS IMPACT FEE ADMIN | (¤53.07) | 03/14/2023 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤20,175.97 |