Permit #2023020708

Permit Details

Status: FINAL

Parcel Id: 14-11-30-5538-00000-0110
Block: 00000
Subdivision: -
Job Phone: 904-469-4718
Location Address: 3 ADVENTHEALTH WAY
Type: FCA - COMMERCIAL FIRE ALARM
Issue Date: 03/22/2023
NOC: Unknown
Applicant name: THOMAS LEE MILHON
Owner: MEMORIAL HOSPITAL-FLAGLER INC

Address

60 MEMORIAL MEDICAL PKWY

PALM COAST, FL 32164

Lot: 0110
Contracted Stated Job Value: ¤31,503.00
Job Description: Fire Alarm
Type: CN

Contractor

JACKSONVILLE SOUND & COMMUNICATIONS INC
Status Location Address State License Number Phone Fax
ACTIVE

5021 STEPP AVE

JACKSONVILLE, FL 32216

EF20000375 (Exp: 08/31/2026) 904-737-3511 904-737-8553

Inspection History

Type Request Date Result Inspector
FIRE ALARM FINAL 06/02/2023 FINAL APPROVED RMARTIN
Note: 6/2/23 state inspector passed 5/26/2023 - PREVIOUS INSPECTION NOTES 5/26/23 pending elevator 5/25/2023 - PREVIOUS INSPECTION NOTES
FIRE ALARM FINAL 05/26/2023 PARTIALLY APPROVED RMARTIN
Note: 5/26/23 pending elevator 5/25/2023 - PREVIOUS INSPECTION NOTES
FIRE ALARM FINAL 05/25/2023 CANCELLED BY APPLICANT RMARTIN
FIRE ALARM 1ST ROUGH 04/17/2023 APPROVED RMARTIN
Note: 4/14/2023 - PREVIOUS INSPECTION NOTES 4/12/2023 - PREVIOUS INSPECTION NOTES 4/12/23 need approved stamped set of plans on site for inspection 4/11/2023 - PREVIOUS INSPECTION NOTES 1ST FLOOR, NEED TO HAVE APPROVED PLANS ON SITE FOR NEXT INSPECTIONS 4/14/23 Arrived on site at 8:30 am walked the building and there was no fire alarm tech on site.
FIRE ALARM 1ST ROUGH 04/14/2023 Disapproved - NO FEE JMUNSON
Note: 4/12/2023 - PREVIOUS INSPECTION NOTES 4/12/23 need approved stamped set of plans on site for inspection 4/11/2023 - PREVIOUS INSPECTION NOTES 1ST FLOOR, NEED TO HAVE APPROVED PLANS ON SITE FOR NEXT INSPECTIONS 4/14/23 Arrived on site at 8:30 am walked the building and there was no fire alarm tech on site.
FIRE ALARM 1ST ROUGH 04/12/2023 Disapproved - NO FEE RMARTIN
Note: 4/12/23 need approved stamped set of plans on site for inspection 4/11/2023 - PREVIOUS INSPECTION NOTES 1ST FLOOR, NEED TO HAVE APPROVED PLANS ON SITE FOR NEXT INSPECTIONS
FIRE ALARM 1ST ROUGH 04/11/2023 PARTIALLY APPROVED RMARTIN
Note: 1ST FLOOR, NEED TO HAVE APPROVED PLANS ON SITE FOR NEXT INSPECTIONS

Review History

Department Status Date In Date Out
FI1 COMPLETE 03/20/2023 03/21/2023
Note: Released By: LEE MILLER - (386)986-3783 - WMILLER@PALMCOASTGOV.COM
BADMIN HOLD 03/16/2023 03/16/2023
Note: Held By: BARBIE BEMBRY - (386)986-3780 - BUILDINGDIVISION@PALMCOASTGOV.COM This permit should have been aplied for under 3 Advent Health Way. You will either need to reapply and resubmit under that address, OR submit a signed and notarized permit appilcation with the correct address requesting the permit to be updated to 3 Advent Health Way if this permit is for the MOB building.
BADMIN COMPLETE 03/16/2023 03/16/2023
Note: Released By: BARBIE BEMBRY - (386)986-3780 - BUILDINGDIVISION@PALMCOASTGOV.COM
FI1 HOLD 03/09/2023 03/16/2023
Note: Held By: LEE MILLER - (386)986-3783 - WMILLER@PALMCOASTGOV.COM Please provide a written response to each comment below in a response letter and provide clouded response changes on plan sheets and add page locations for each response. 1. The address is still not correct, the address should be: 3 Advent Health Way. Please revise the application and all documents with the correct address 2. On sheet FA.01 there is a note indicating this is to expand the existing 4 voice fire alarm system for a tenant buildout. There are devices on floor plans that are not identified. (It has been determined that this project is new construction for the MOB at Advent Health Way. Any notes concerning expansion of system and existing components need to be removed). 3. On sheets FA.03 and FA.04 there are device addresses on the plans with multiple addresses for the riser diagram, please clarify the pathways on the plans and indicate the proper path on the riser diagram. Please make the corrections for review.
FI1 HOLD 02/15/2023 02/22/2023
Note: Held By: LEE MILLER - (386)986-3783 - WMILLER@PALMCOASTGOV.COM Please provide a written response to each comment below in a response letter and provide clouded response changes on plan sheets and add page locations for each response. 1. Please upload Equipment Technical Data Sheets per NFPA 72:7.2.1 (5) 2. Please upload Manufacturers’ published instructions, including operation and maintenance instructions per NFPA 72:7.2.1 (6) 3. On sheet FA.04 there is a note indicating this is to expand the existing 4 voice fire alarm system for a tenant buildout. There are devices on floor plans that are not identified. (Please identify all devices including those that are existing, those that are to be replaced if any, and all new devices). 4. Please provide Pathway Classification per NFPA 72:12.3 5. On sheets FA.03 and FA.04 there are devices on the plans with multiple addresses for the riser diagram, please clarify the pathways on the plans and indicate the proper path on the riser diagram. (For instance on sheet FA.04 see V3-13 and A2-8).

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
ADJUSTMENT 50% (¤261.10) 03/22/2023
ADMINISTRATIVE - COMMERCIAL ¤75.00 03/22/2023
INSPECTION - FIRE COMMERCIAL ¤79.20 03/22/2023
PLAN REVIEW - COMMERCIAL ¤368.00 03/22/2023
SURCHARGE FS 533.721 ¤2.68 03/22/2023
SURCHARGE - FS 468.631 ¤4.02 03/22/2023
Fees Total Due: ¤0.00 Total Paid: ¤267.80