Permit #2023020841
Permit Details
Status: COED
| Parcel Id: 08-12-31-0650-000A0-0090 |
| COMMERCIAL SQUARE FOOTAGE: 6600 sqft |
| Total Square Footage: 6600 sqft |
| Block: 000A0 |
| Subdivision: 1033 - COASTAL PARK OF BUNNELL |
| Job Phone: 386-237-0328 |
| Location Address: 5850 STATE HWY 100 E |
| Type: CA - COMM ADDITION |
| Issue Date: 05/18/2023 |
| NOC: RECORDED |
| Applicant name: JAMES JOSEPH ALBANO |
| Owner: TLG LLC |
|
Address 5850 E HWY 100 PALM COAST, FL 32164 |
| Lot: 0090 |
| Contracted Stated Job Value: ¤300,000.00 |
| Job Description: SERVICE BUILDING ADDITION - TOM GIBBS CHEVROLET |
| Type: CN |
Contractor
ALBANO DESIGNS STUDIOS, INC
| Status | Location Address | State License Number | Phone |
| ACTIVE |
82 LEE DR PALM COAST, FL 32137 |
CBC050078 (Exp: 08/31/2026) | 386-237-0328 |
Sub Contractors
FREDERICK JOSEPH PREVOST
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
887 BRENTWOOD DRIVE DAYTONA BEACH, FL 0 |
CMC1250152 (Exp: 08/31/2026) | 386-252-7047 | 386-257-7819 |
WILLIAM FRANK DUDLEY JR.
| Status | Location Address | State License Number | Phone |
| ACTIVE |
P.O. BOX 978 Bunnell, FL 32110 |
EC0003177 (Exp: 08/31/2026) | (386)437-3068 |
Inspection History
| Type | Request Date | Result | Inspector |
| BUILDING FINAL | 02/21/2024 | FINAL APPROVED | FWILLIS |
| U - UTILITY COMMERCIAL FINAL | 02/21/2024 | FINAL APPROVED | JHARDING |
| HVAC FINAL | 02/20/2024 | FINAL APPROVED | CPISCITELLI |
| Note: 1/4/2024 - PREVIOUS INSPECTION NOTES Submit mechanical plan revision for change of location of mechanical exhaust fan. | |||
| LDSC- LANDSCAPE FINAL | 01/30/2024 | APPROVED | TDOAK |
| Note: 1/12/2024 12:09:11 PM- PREVIOUS INSPECTION NOTES 1. Provide clean up and mulch for existing parking island locate south of builidng addition. 2. Remove dead shade in landscape area located at southwest corner of property and Provide one new shade tree on the property at 3.5" caliper as replacement. 1/29/24 Please approve the landscape hold for the Tom Gibbs permit. Rick is out and our agreement with them regarding the landscape was to replace a dead tree. This was accomplished. Thanks, Ray | |||
| LDSC- LANDSCAPE FINAL | 01/12/2024 | Disapproved - NO FEE | RPICATAGI |
| Note: 1. Provide clean up and mulch for existing parking island locate south of builidng addition. 2. Remove dead shade in landscape area located at southwest corner of property and Provide one new shade tree on the property at 3.5" caliper as replacement. | |||
| FIRE FINAL | 01/11/2024 | APPROVED | RMARTIN |
| HVAC ROUGH | 01/11/2024 | APPROVED | CPISCITELLI |
| Note: 1/4/2024 - PREVIOUS INSPECTION NOTES Submit mechanical plan revision for change of location of mechanical exhaust fan. | |||
| PLUMBING FINAL | 01/11/2024 | APPROVED | MGIBSON |
| Note: 1/4/2024 - PREVIOUS INSPECTION NOTES | |||
| FRAMING | 01/10/2024 | APPROVED | FWILLIS |
| Note: 1/4/2024 - PREVIOUS INSPECTION NOTES All exterior wall framing members have been covered. | |||
| INSULATION | 01/10/2024 | APPROVED | FWILLIS |
| Note: 1/4/2024 - PREVIOUS INSPECTION NOTES Exterior walls call for R-19 insulation. Walls have been covered, stucco at the exterior, corrugated metal panel at the interior. Ceilings call for R-30 insulation unable to verify type of insulation at ceilings. No markings or labels. Due to the insulation being covered. Interior metal wall panels will need to be removed in order to inspect insulation. | |||
| ELECTRIC FINAL | 01/05/2024 | APPROVED | RMARTIN |
| Note: 1/3/2024 - PREVIOUS INSPECTION NOTES NEED REVISION SHOWING PANEL CHANGE AND CIRCUIT CHANGES | |||
| FRAMING | 01/04/2024 | Disapproved - NO FEE | JWALKER |
| Note: All exterior wall framing members have been covered. | |||
| HVAC ROUGH | 01/04/2024 | Disapproved - NO FEE | PBUCKLEY |
| Note: Submit mechanical plan revision for change of location of mechanical exhaust fan. | |||
| PLUMBING 2ND ROUGH | 01/04/2024 | Disapproved - NO FEE | JWALKER |
| Note: Contrator stated a seperate permit was pulled to install copper piping and galvanized steel piping for gas lines. Unable to locate the seperate pulled permit. Piping is completed, no piping under test. | |||
| PLUMBING FINAL | 01/04/2024 | CANCELLED BY APPLICANT | JWALKER |
| HVAC FINAL | 01/04/2024 | Disapproved - NO FEE | PBUCKLEY |
| Note: Submit mechanical plan revision for change of location of mechanical exhaust fan. | |||
| INSULATION | 01/04/2024 | Disapproved -FEE REQUIRED | JWALKER |
| Note: Exterior walls call for R-19 insulation. Walls have been covered, stucco at the exterior, corrugated metal panel at the interior. Ceilings call for R-30 insulation unable to verify type of insulation at ceilings. No markings or labels. Due to the insulation being covered. Interior metal wall panels will need to be removed in order to inspect insulation. | |||
| ELECTRIC 2ND ROUGH | 01/03/2024 | APPROVED | RMARTIN |
| ELECTRIC FINAL | 01/03/2024 | Disapproved - NO FEE | RMARTIN |
| Note: NEED REVISION SHOWING PANEL CHANGE AND CIRCUIT CHANGES | |||
| FOUND SURVEY APPROVED (OFFICE) | 01/02/2024 | APPROVED | DLEAP |
| ELECTRIC FINAL | 11/28/2023 | CANCELLED BY APPLICANT | WEB |
| LATH/BRICK/WATER BARRIER | 10/17/2023 | APPROVED | JWALKER |
| Note: 10/4/2023 - PREVIOUS INSPECTION NOTES SOUTH AND EAST SIDES | |||
| LATH/BRICK/WATER BARRIER | 10/04/2023 | PARTIALLY APPROVED | FWILLIS |
| Note: SOUTH AND EAST SIDES | |||
| TIE BEAM | 07/24/2023 | APPROVED | FWILLIS |
| MONOLITHIC SLAB | 06/14/2023 | APPROVED | FWILLIS |
Review History
| Department | Status | Date In | Date Out |
| PLLA | COMPLETE | 01/30/2024 | 01/30/2024 |
| Note: Released By: DAMARIS RAMIREZ - (386)986-3750 - DRAMIREZ@PALMCOASTGOV.COM This review and approved is being conducted on Ricks absence. If more is required the Landscape Architect can make further comments. | |||
| ARCHR | CANCEL | 01/17/2024 | 01/30/2024 |
| BLD | CANCEL | 01/17/2024 | 01/19/2024 |
| MECH | COMPLETE | 01/04/2024 | 01/11/2024 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| ELEC | COMPLETE | 01/03/2024 | 01/04/2024 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| PLENG | COMPLETE | 01/02/2024 | 01/02/2024 |
| Note: Released By: DENNIS R. LEAP, P.E. - (386)986-2482 - DLEAP@PALMCOASTGOV.COM | |||
| ELEC | COMPLETE | 05/03/2023 | 05/03/2023 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 05/03/2023 | 05/09/2023 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 05/03/2023 | 05/16/2023 |
| Note: Released By: PATRICK BUCKLEY - (386)986-3786 - PBUCKLEY@PALMCOASTGOV.COM | |||
| PLUM | COMPLETE | 05/03/2023 | 05/16/2023 |
| Note: Released By: PATRICK BUCKLEY - (386)986-3786 - PBUCKLEY@PALMCOASTGOV.COM | |||
| BLD | HOLD | 04/10/2023 | 04/10/2023 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM THIS IS THE CORRECT REVIEW PREVIOUS WAS DONE IN ERROR. Plan Sheet A-1.3 and A-1.4 1. REPEAT COMMENT. Provide geotechnical investigation report per FBCB Section 1803. Copy of original / existing geotechnical report is suitable. Reference geotechnical investigation report number on foundation plans. 2. REPEAT COMMENT. Provide foundation design loads per FBCB Section 1808.3, and load combinations per 1605.2 or 1605.3. 3. REPEAT COMMENT. Provide description of sub-grade requirements per geotechnical investigation report and if any excavation and / or placement of structural fill is necessary, provide design details and specifications. 4. REPEAT COMMENT. Provide concentrated design loads for vehicle lifts. 5. REPEAT COMMENT. Provide soil design bearing values and vertical and lateral foundation bearing pressure values per FBCB Section 1806.1, based on geotechnical investigation. Palm Coast Roofing Worksheet 1. REPEAT COMMENT. Add exterior wall panels product approval number to worksheet. YOU NEED TO UPLOAD A PRODUCT APPROVAL WORKSHEET WITH THIS INFORMATION. 2. REPEAT COMMENT. Add skylights product approval number to worksheet. YOU NEED TO UPLOAD A PRODUCT APPROVAL WORKSHEET WITH THIS INFORMATION. 3. REPEAT COMMENT. Add stucco or EIFS system approval number to worksheet. Exterior elevations depict a stucco cladding for this building. YOU NEED TO UPLOAD A PRODUCT APPROVAL WORKSHEET WITH THIS INFORMATION. | |||
| PLUM | HOLD | 04/10/2023 | 04/10/2023 |
| Note: Held By: PATRICK BUCKLEY - (386)986-3786 - PBUCKLEY@PALMCOASTGOV.COM THIS IS THE CORRECT REVIEW. PREVIOUS WAS DONE IN ERROR. All comments below per the 2020 Florida Building Code-Building (FBCB) and 2020 FLorida Building Code-Plumbing (FBCP) 1. REPEAT COMMENT. Provide plumbing fixture calculations based on occupant load of addition in conjunction with occupant load of existing floor areas to determine whther additional bathrooms, and / or plumbing fixtures are reqwuried due to the increase in the number of occupants. FBCB Section 2902.1 and Table 2902.1. If addtional plumbing fixtures are required provide complete plans influcing floor plan, water distribution, sanitary drainage, etc. 2. REPEAT COMMENT. If it is the intent to treat this as a portable station without connection to water supply or drainage system, please provide product manufacturer information and details. | |||
| FI1 | COMPLETE | 03/30/2023 | 03/30/2023 |
| Note: Released By: LEE MILLER - (386)986-3783 - WMILLER@PALMCOASTGOV.COM disregard hold that was placed on permit for fire moments ago, that was accidental. Fire review is complete | |||
| ARCHR | COMPLETE | 03/27/2023 | 04/11/2023 |
| Note: Released By: RICHARD PICATAGI - (386)986-3760 - RPICATAGI@PALMCOASTGOV.COM Clarify steel panel color listed as Galvalume - provide manufacturer code number, and LRV | |||
| PLENG | COMPLETE | 03/27/2023 | 03/28/2023 |
| Note: Released By: DENNIS R. LEAP, P.E. - (386)986-2482 - DLEAP@PALMCOASTGOV.COM | |||
| UD1 | COMPLETE | 03/27/2023 | 04/12/2023 |
| Note: Released By: JACQUELINE GONZALEZ - (386)986-3751 - JGONZALEZ@PALMCOASTGOV.COM per brice complete | |||
| FI1 | HOLD | 03/27/2023 | 03/30/2023 |
| Note: Held By: LEE MILLER - (386)986-3783 - WMILLER@PALMCOASTGOV.COM | |||
| DSD | COMPLETE | 03/27/2023 | 03/28/2023 |
| Note: Released By: JACQUELINE GONZALEZ - (386)986-3751 - JGONZALEZ@PALMCOASTGOV.COM | |||
| ELEC | HOLD | 03/27/2023 | 04/04/2023 |
| Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Submit a riser diagram showing wire sizes and main breaker size for new panel. | |||
| MECH | HOLD | 03/27/2023 | 04/06/2023 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM 1.Provide details on mechanical plans or manufacturer' specs showing source and capture ventilation per Section 502.14 FBC Mechanical 2020 7th edition (Second Request) | |||
| PLUM | HOLD | 03/27/2023 | 04/10/2023 |
| Note: Held By: PATRICK BUCKLEY - (386)986-3786 - PBUCKLEY@PALMCOASTGOV.COM All comments below per the 2020 Florida Building Code-Building (FBCB) and 2020 FLorida Building Code-Plumbing (FBCP) 1. REPEAT COMMENT. Provide plumbing fixture calculations based on occupant load of addition in conjunction with occupant load of existing floor areas to determine whther additional bathrooms, and / or plumbing fixtures are reqwuried due to the increase in the number of occupants. FBCB Section 2902.1 and Table 2902.1. If addtional plumbing fixtures are required provide complete plans influcing floor plan, water distribution, sanitary drainage, etc. 2. REPEAT COMMENT. Plans indicate the presence of an emergency eyewash station. Eyewash station is a plumbigng fixture by definition in the FBCP and must be connected to the builidng's plumbing systems (potable water and sewer). Provide informaton on water supply and drainage connections for this station. If it is the intent to treat this as a portable station without connection to water supply or drainage system, please provide product manufacturer information and details. 3. REPEAT COMMENT. Provide roof drainage caculations and gutter sizing based on g.p.m. flow rated per FBCB Section 1514.4.3 and FBCP Section 1106.6. Provide downspout sizing, locations and discharge points. Provide gutter and downspout materials specifications and attachment details per FBCB Section 1503.4.3 and roof edge flashing detail per FBCB Section 1503.2.1`. | |||
| BLD | HOLD | 03/27/2023 | 04/10/2023 |
| Note: Held By: PATRICK BUCKLEY - (386)986-3786 - PBUCKLEY@PALMCOASTGOV.COM All Comments Below per the 2020 Florida Building Code-Building (FBCB) and 2020 Florida Building Code-Existing Building (FBCEB). Plan Sheet CS 1. Determine whether this mixed occupancy building qualifies for unseparated uses or has / requires separated uses per Section 508. If separated uses are required, provide occupancy separation construction details per Section 508.4 and Table 508.4. 2. Provide list of deferred submittals per FBCB Section 107.3.4.1 (e.g. shop drawings). 3. REPEAT COMMENT: Provide details of the exterior wall envelope per FBCB Section 107.2.4 for each wall section and each exterior cladding type. Provide exterior cladding design wind pressures Per Provide full wall sections from interior finished surface to exterior finished surface. Provide manufacturer’s specifications for stucco system for a complete exterior wall cladding system. Provide exterior flashing details at all exterior openings and any dissimilar materials. Chapter 14, Sections 1404.1, 1404.2, 1405.4, 1405.15, 2507.1, Table 2507.2, 2507.2, 2510.1 through 2510.7. 2512.1 through 2512.9. MANUFACTURER’S SPECS PROVIDED FOR PROPOSED STUCCO SYSTEM BUT DETAILS RE GENERIC MANUFACTURER’S REQUIREMENTS. ARCHITECTURAL AND / OR STEEL BUILDING PLANS NOT UPDATED TO REFLECT COMPLETE WALL SECTIONS OR CONSTRUCTION DETAILS FOR EXTERIOR WALL CONSTRUCTION NECESSARY TO RECEIVE STUCCO INSTALLATION. Plan Sheet A-1.3 and A-1.4 1. REPEAT COMMENT. Provide geotechnical investigation report per FBCB Section 1803. Copy of original / existing geotechnical report is suitable. Reference geotechnical investigation report number on foundation plans. 2. REPEAT COMMENT. Provide foundation design loads per FBCB Section 1808.3, and load combinations per 1605.2 or 1605.3. 3. REPEAT COMMENT. Provide description of sub-grade requirements per geotechnical investigation report and if any excavation and / or placement of structural fill is necessary, provide design details and specifications. 4. REPEAT COMMENT. Provide concentrated design loads for vehicle lifts. 5. REPEAT COMMENT. Provide soil design bearing values and vertical and lateral foundation bearing pressure values per FBCB Section 1806.1, based on geotechnical investigation. 6. REPEAT COMMENT. Provide minimum compressive strength for concrete per Section 1808.8.1 and Table 1808.1 or per geotechnical investigation report, whichever is more restrictive. Palm Coast Roofing Worksheet 1. REPEAT COMMENT. Add exterior wall panels product approval number to worksheet. YOU NEED TO UPLOAD A PRODUCT APPROVAL WORKSHEET WITH THIS INFORMATION. 2. REPEAT COMMENT. Add skylights product approval number to worksheet. YOU NEED TO UPLOAD A PRODUCT APPROVAL WORKSHEET WITH THIS INFORMATION. 3. REPEAT COMMENT. Add stucco or EIFS system approval number to worksheet. Exterior elevations depict a stucco cladding for this building. YOU NEED TO UPLOAD A PRODUCT APPROVAL WORKSHEET WITH THIS INFORMATION. | |||
| PLENG | COMPLETE | 03/07/2023 | 03/07/2023 |
| Note: Released By: DENNIS R. LEAP, P.E. - (386)986-2482 - DLEAP@PALMCOASTGOV.COM | |||
| ELEC | HOLD | 02/27/2023 | 02/27/2023 |
| Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Need to reference the 2017 NEC 2. Need to classify the garage as defined in NEC 2017 511.2 and show the class and division. 3. Need to submit a spec sheet showing all conduits, connectors, boxes, wiring and lighting comply with the divivson the garage is classifed as. 4. GFCI outlets need to be shown on plans as defined in NEC 2017 210.8 (B) | |||
| ARCHR | COMPLETE | 02/16/2023 | 03/02/2023 |
| Note: Released By: RICHARD PICATAGI - (386)986-3760 - RPICATAGI@PALMCOASTGOV.COM | |||
| BLD | HOLD | 02/16/2023 | 03/07/2023 |
| Note: Held By: PATRICK BUCKLEY - (386)986-3786 - PBUCKLEY@PALMCOASTGOV.COM All Comments Below per the 2020 Florida Building Code-Building (FBCB) and 2020 Florida Building Code-Existing Building (FBCEB). Plan Sheet CS Building Code Summary Note 2. 1. Add reference to the 2020 Florida Building Code-Existing Building. This is a governing code for additions to existing buildings. Designate the classification of work per Chapter 6, Section 606. Provide code analysis per Chapter 11 in order to determine which of the code provisions therein apply to the existing building and addition. Revise plans accordingly. See No. 4 below as Section 1102 relates to items in Chapter 5 and 6 FBCB. 2. Provide full occupancy classification of all occupancies in the building per FBCB Section 302.1. Group B (FBCB Section 304.1) applies to the vehicle showroom only. Repair garages including this repair garage addition are classified as Group S-1 (FBCB Section 311.2). Include other accessory occupancies such as storage rooms FBCB Section 508.1, 508.2). 3. Correct construction type to one of those listed in FBCB Section 602.1 through 602.5. Follow number convention using Roman numerals. Indicate whether construction is protected (A) or unprotected (B). Original building plans indicate a Type 4 construction. It should have been listed as Type IV construction. Please revise. 4. Provide building height, area and number of stories analysis for existing building plus the proposed addition based on a mixed occupancy building as described in No. 2 above. Solve actual building areas, heights and stories based on the occupancy classifications in Chapter 3 and construction type in Chapter 6 (IIB) as fully described in Section 503.1. Solve building height and number of stories per Section 504 as modified by Section 504.2 and illustrated in Tables 504.3a and 504.4. Solve building area per Section 504 as modified by Section 506.2.2 and illustrated in Table 506.2. Determine whether building qualifies for area increases if building exceeds tabular values in Table 506.2. Determine whether building can be an unlimited area building per Section 507. D 5. Determine whether this mixed occupancy building qualifies for unseparated uses or has / requires separated uses per Section 508. If separated uses are required, provide occupancy separation construction details per Section 508.4 and Table 508.4. 6. Provide list of deferred submittals per FBCB Section 107.3.4.1 (e.g. shop drawings). 7. Add note that a separate permit is required for extending the existing fire sprinkler system to this addition. Please be advised, in the absence of any Florida PE engineering system design basis in these plans, the fire sprinkler contractor will be required to produce engineering in addition to any working drawings for the system at time of permit application. 8. Provide details of the exterior wall envelope per FBCB Section 107.2.4 for each wall section and each exterior cladding type. Provide exterior cladding design wind pressures Per Provide full wall sections from interior finished surface to exterior finished surface. Provide manufacturer’s specifications for stucco system for a complete exterior wall cladding system. Provide exterior flashing details at all exterior openings and any dissimilar materials. Chapter 14, Sections 1404.1, 1404.2, 1405.4, 1405.15, 2507.1, Table 2507.2, 2507.2, 2510.1 through 2510.7. 2512.1 through 2512.9. Plan Sheet A-1.3 and A-1.4 1. Provide geotechnical investigation report per FBCB Section 1803. Copy of original / existing geotechnical report is suitable. Reference geotechnical investigation report number on foundation plans. 2. Provide foundation design loads per FBCB Section 1808.3, and load combinations per 1605.2 or 1605.3. 3. Provide description of sub-grade requirements per geotechnical investigation report and if any excavation and / or placement of structural fill is necessary, provide design details and specifications. 4. Provide concentrated design loads for vehicle lifts. 5. Provide soil design bearing values and vertical and lateral foundation bearing pressure values per FBCB Section 1806.1, based on geotechnical investigation. 6. Provide minimum compressive strength for concrete per Section 1808.8.1 and Table 1808.1 or per geotechnical investigation report, which ever is more restrictive. Steel building plans (all) 1. Provide engineer’s digital seal in accordance with F.S. 471.025 and Florida Administrative Code Section 61G15-23.004. Steel Building Plan Sheet (identified in permit system as S-Cover 2.pdf) (No sheet number on plan sheet itself) 1. In the Roof Panel Section, remove reference to PBR 22 gage / 24 gage roof panels with NOA-21-0615.03 metal roof panels. NOA file number is expired. Palm Coast Roofing Worksheet 1. Revise Roofing worksheet to reflect roof panels referenced by the steel building engineer. 2 choices are given, NOA-21-0615.06 and NOA-21-0615.07. 2. Add exterior wall panels product approval number to worksheet. 3. Add skylights product approval number to worksheet. 4. Add stucco or EIFS system approval number to worksheet. Exterior elevations depict a stucco cladding for this building. | |||
| DSD | HOLD | 02/16/2023 | 02/24/2023 |
| Note: Held By: DAMARIS RAMIREZ - (386)986-3750 - DRAMIREZ@PALMCOASTGOV.COM On the sheet CS provide a site data table with the following information.: 1. Property parcel number. 2. Property address 3. Property zoning district. 4. Existing building square footage and proposed additional square footage. 5. Existing parking count and proposed parking reduction count after the elimination of parking areas. 6. Add addition dimensions. 7. Addition use. Is it an office? | |||
| ELEC | COMPLETE | 02/16/2023 | 02/27/2023 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Need to reference the 2017 NEC 2. Need to classify the garage as defined in NEC 2017 511.2 and show the class and division. 3. Need to submit a spec sheet showing all conduits, connectors, boxes, wiring and lighting comply with the divivson the garage is classifed as. 4. GFCI outlets need to be shown on plans as defined in NEC 2017 210.8 (B) | |||
| FI1 | HOLD | 02/16/2023 | 02/22/2023 |
| Note: Held By: LEE MILLER - (386)986-3783 - WMILLER@PALMCOASTGOV.COM 1. Please remove reference to NFPA 1, NFPA 101, and remove the FBC form the FFPC reference. (The Florida specific versions of NFPA 1 and 101 are within the 7th edition of FFPC). 2. Please change the reference to NFPA13 from 2022 to the current approved version of 2016. 3. Please acknowledge the following note was placed on the permit: Any construction alterations having effect on the building fire sprinkler system and or fire alarm system layout, coverage, or additions, shall be addressed by a fire protection contractor under a separate permit prior to project completion and approval per FFPC, NFPA 1, Fire Code section 1.12.8 4. Please show the Required Emergency lighting on the Life Safety Plan per FFPC 1: 14.13 | |||
| MECH | HOLD | 02/16/2023 | 03/02/2023 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM 1.Provide Mechanical plans showing ventilation per Section 403 and Section 502.14 FBC Mechanical 2020 7th edition 2. Provide manufacturers specs on fans and motors showing compliance with Section 503 FBC Mechanical 2020 7th edition | |||
| PLUM | HOLD | 02/16/2023 | 03/06/2023 |
| Note: Held By: PATRICK BUCKLEY - (386)986-3786 - PBUCKLEY@PALMCOASTGOV.COM All comments below per the 2020 Florida Building Code-Building (FBCB) and 2020 FLorida Building Code-Plumbing (FBCP) 1. Provide plumbing fixture calculations based on occupant load of addition in conjunction with occupant load of existing floor areas to determine whther additional bathrooms, and / or plumbing fixtures are reqwuried due to the increase in the number of occupants. FBCB Section 2902.1 and Table 2902.1. If addtional plumbing fixtures are required provide complete plans influcing floor plan, water distribution, sanitary drainage, etc. 2. Plans indicate the presence of an emergency eyewash station. Eyewash station is a plumbigng fixture by definition in the FBCP and must be connected to the builidng's plumbing systems (potable water and sewer). Provide informaton on water supply and drainage connections for this station. If it is the intent to treat this as a portable station without connection to water supply or drainage system, please provide product manufacturer information and details. 3. Provide roof drainage caculations and gutter sizing based on g.p.m. flow rated per FBCB Section 1514.4.3 and FBCP Section 1106.6. Provide downspout sizing, locations and discharge points. Provide gutter and downspout materials specifications and attachment details per FBCB Section 1503.4.3 and roof edge flashing detail per FBCB Section 1503.2.1`. | |||
| UD1 | HOLD | 02/16/2023 | 02/21/2023 |
| Note: Held By: BRICE WRIGHT - - Additional fees and revised agreement needed for new addition |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| ADJUSTMENT 50% | (¤1,260.00) | 05/18/2023 |
| ADMINISTRATIVE - COMMERCIAL | ¤75.00 | 05/18/2023 |
| INSPECTION COMMERCIAL | ¤2,100.00 | 05/18/2023 |
| PLAN REVIEW - COMMERCIAL | ¤345.00 | 05/18/2023 |
| SURCHARGE FS 533.721 | ¤13.23 | 05/18/2023 |
| SURCHARGE - FS 468.631 | ¤19.85 | 05/18/2023 |
| SW ENG REVIEW- 40 | ¤40.00 | 05/18/2023 |
| SITE PLAN 30 | ¤30.00 | 05/18/2023 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤1,363.08 |