Permit #2023030106

Permit Details

Status: COED

Parcel Id: 07-11-31-7025-000D0-0180
Total Square Footage: 4547 sqft
Block: 000D0
Subdivision: 1228 - SOUTHWEST QUADRANT
Job Phone: 904-323-8928
Location Address: 3 CYPRESS BRANCH WAY
Type: CIA - COMMERCIAL INTERIOR EXTERIOR ALTERATION
Issue Date: 07/25/2023
NOC: RECORDED
Applicant name: BENTLEY JAMES BRADLEY
Owner: CYPRESS POINT INVESTORS INC

Address

P O BOX 350855

PALM COAST, FL 32135

Lot: 0180
Contracted Stated Job Value: ¤350,000.00
Job Description: UNIT 107 - INTERIOR RENOVATION - DENTAL SPECIALISTS OF NORTH FLORIDA
Type: CN

Contractor

BENT CONSTRUCTION, LLC
Status Location Address State License Number Phone
ACTIVE

4446 HENDRICKS AVE #109

JACKSONVILLE, FL 32207

CGC1524472 (Exp: 08/31/2026) 904-323-8928

Sub Contractors

RAYMOND A PASUKINSKI
Status Location Address Mailing Address State License Number Phone
ACTIVE

5605 FLORIDA MINING BLVD S

JACKSONVILLE, FL 32257

SUITE 210

JACKSONVILLE, FL 32257

EC13005820 (Exp: 08/31/2026) 904-880-0333
CHRISTOPHER JAMES LEO
Status State License Number
INACTIVE CAC057734 (Exp: 08/31/2024)
NICHOLAS JOSEPH BRYAN GAY
Status Location Address State License Number Phone
INACTIVE

1518 WHITLOCK AVENUE

JACKSONVILLE, FL 32216

CFC1429377 (Exp: 08/31/2024) 904-322-2301

Inspection History

Type Request Date Result Inspector
PLUMBING FINAL 02/14/2024 CANCELLED BY APPLICANT WEB
Note: 2/13/2024 - PREVIOUS INSPECTION NOTES Inspector Notes from Inspection 3080 Inspector Notes from Inspection 3080 Inspector Notes from Inspection 3070 THIS WAS FOR WASTE,VENT WATER, ''COMPRESSED AIR'' AND VACCUUME LINES ALL ARE APPROVED ONE SIDE OF DRYWALL WAS INSTALLED BEFORE PLUMBER COUL INSTALL NAIL PLATES WILL BE DONE BY VIRTUAL INSPECTION ON ALL OPERATORIES ANOTHER MONOLITHIC SLAB INSPECTION WAS ADDED DUE TO CONCRETE BEING BUSTED FOR ADDITIONAL BATHROOM,LAV, AND DRINKING FOUNTAIN BOTH ''ADA' TOILETS NEED TO HAVE FLUSH VALVE TO OPEN SIDE AND NEED TO HAVE OPEN FRONT LESS COVER SEATS
PLUMBING FINAL 02/14/2024 APPROVED MGIBSON
Note: New inspection due to canceled inspection 2/13/2024 - PREVIOUS INSPECTION NOTES Inspector Notes from Inspection 3080 Inspector Notes from Inspection 3080 Inspector Notes from Inspection 3070 THIS WAS FOR WASTE,VENT WATER, ''COMPRESSED AIR'' AND VACCUUME LINES ALL ARE APPROVED ONE SIDE OF DRYWALL WAS INSTALLED BEFORE PLUMBER COUL INSTALL NAIL PLATES WILL BE DONE BY VIRTUAL INSPECTION ON ALL OPERATORIES ANOTHER MONOLITHIC SLAB INSPECTION WAS ADDED DUE TO CONCRETE BEING BUSTED FOR ADDITIONAL BATHROOM,LAV, AND DRINKING FOUNTAIN BOTH ''ADA' TOILETS NEED TO HAVE FLUSH VALVE TO OPEN SIDE AND NEED TO HAVE OPEN FRONT LESS COVER SEATS
BUILDING FINAL 02/14/2024 FINAL APPROVED FWILLIS
Note: PENDING PLUMBING FINAL Inspector Notes from Inspection 3470 1/31/2024 - PREVIOUS INSPECTION NOTES need to seal connections at grills with tape need to strap lines, repair return lines in back office. will inspect on final
FIRE FINAL 02/13/2024 APPROVED LMILLER
U - UTILITY COMMERCIAL FINAL 02/13/2024 FINAL APPROVED LFITZGERALD
ELECTRIC FINAL 02/13/2024 APPROVED MKRASKI
Note:
PLUMBING FINAL 02/13/2024 Disapproved - NO FEE MGIBSON
Note: Inspector Notes from Inspection 3080 Inspector Notes from Inspection 3080 Inspector Notes from Inspection 3070 THIS WAS FOR WASTE,VENT WATER, ''COMPRESSED AIR'' AND VACCUUME LINES ALL ARE APPROVED ONE SIDE OF DRYWALL WAS INSTALLED BEFORE PLUMBER COUL INSTALL NAIL PLATES WILL BE DONE BY VIRTUAL INSPECTION ON ALL OPERATORIES ANOTHER MONOLITHIC SLAB INSPECTION WAS ADDED DUE TO CONCRETE BEING BUSTED FOR ADDITIONAL BATHROOM,LAV, AND DRINKING FOUNTAIN BOTH ''ADA' TOILETS NEED TO HAVE FLUSH VALVE TO OPEN SIDE AND NEED TO HAVE OPEN FRONT LESS COVER SEATS
HVAC FINAL 02/07/2024 FINAL APPROVED CPISCITELLI
Note: 2/6/2024 - PREVIOUS INSPECTION NOTES 1/31/2024 - PREVIOUS INSPECTION NOTES Inspector Notes from Inspection 3160 12/22/23 Overhead trunk ducts, take-offs, volume dampers, drops and bathroom exhaust fan to front soffit left of front door. Termination in soffit not ready.
HVAC FINAL 02/06/2024 CANCELLED BY APPLICANT CPISCITELLI
Note: 1/31/2024 - PREVIOUS INSPECTION NOTES Inspector Notes from Inspection 3160 12/22/23 Overhead trunk ducts, take-offs, volume dampers, drops and bathroom exhaust fan to front soffit left of front door. Termination in soffit not ready.
ABOVE CEILING 02/02/2024 APPROVED - AS NOTED CPISCITELLI
Note: 1/31/2024 - PREVIOUS INSPECTION NOTES need to seal connections at grills with tape need to strap lines, repair return lines in back office. will inspect on final
ELECTRIC FINAL 02/02/2024 Disapproved - NO FEE RMARTIN
Note: need to have power on electrical panel, need gfci protection on outlets within 6' of sinks ELECTRIC GOOD IN DROP SOFFIT AREA, BUT CAN NOT DRYWALL, NEED TO SCHEDULE ROUGH FOR SPRINKLERS
ELECTRIC - EARLY POWER 01/31/2024 APPROVED RMARTIN
Note: 1/26/2024 - PREVIOUS INSPECTION NOTES APPROVED ELECTRICAL RISER DRAWINGS DO NOT MATCH WHAT IS INSTALLED
ABOVE CEILING 01/31/2024 Disapproved - NO FEE RMARTIN
Note: need to seal connections at grills with tape need to strap lines, repair return lines in back office
HVAC FINAL 01/31/2024 CANCELLED BY APPLICANT CPISCITELLI
Note: Inspector Notes from Inspection 3160 12/22/23 Overhead trunk ducts, take-offs, volume dampers, drops and bathroom exhaust fan to front soffit left of front door. Termination in soffit not ready.
HVAC ROUGH 01/31/2024 APPROVED CPISCITELLI
Note: Inspector Notes from Inspection 3160 12/22/23 Overhead trunk ducts, take-offs, volume dampers, drops and bathroom exhaust fan to front soffit left of front door. Termination in soffit not ready.
ELECTRIC FINAL 01/26/2024 CANCELLED BY APPLICANT WEB
Note: Inspector Notes from Inspection 3190 ELECTRIC GOOD IN DROP SOFFIT AREA, BUT CAN NOT DRYWALL, NEED TO SCHEDULE ROUGH FOR SPRINKLERS
ELECTRIC - EARLY POWER 01/26/2024 Disapproved - NO FEE RMARTIN
Note: APPROVED ELECTRICAL RISER DRAWINGS DO NOT MATCH WHAT IS INSTALLED
MONOLITHIC SLAB 01/25/2024 APPROVED FWILLIS
ELECTRIC 2ND ROUGH 01/16/2024 APPROVED - AS NOTED RMARTIN
Note: ELECTRIC GOOD IN DROP SOFFIT AREA, BUT CAN NOT DRYWALL, NEED TO SCHEDULE ROUGH FOR SPRINKLERS
CONCRETE FORM 12/29/2023 APPROVED FWILLIS
PLUMBING 2ND ROUGH 12/22/2023 APPROVED - AS NOTED MGIBSON
Note: Inspector Notes from Inspection 3080 Inspector Notes from Inspection 3070 THIS WAS FOR WASTE,VENT WATER, ''COMPRESSED AIR'' AND VACCUUME LINES ALL ARE APPROVED ONE SIDE OF DRYWALL WAS INSTALLED BEFORE PLUMBER COUL INSTALL NAIL PLATES WILL BE DONE BY VIRTUAL INSPECTION ON ALL OPERATORIES ANOTHER MONOLITHIC SLAB INSPECTION WAS ADDED DUE TO CONCRETE BEING BUSTED FOR ADDITIONAL BATHROOM,LAV, AND DRINKING FOUNTAIN
HVAC OTHER 12/22/2023 APPROVED - AS NOTED PBUCKLEY
Note: 12/22/23 Overhead trunk ducts, take-offs, volume dampers, drops and bathroom exhaust fan to front soffit left of front door. Termination in soffit not ready.
ELECTRIC 2ND ROUGH 12/22/2023 APPROVED RMARTIN
HVAC OTHER 11/29/2023 CANCELLED BY INSPECTOR CPISCITELLI
HVAC ROUGH 11/29/2023 PARTIALLY APPROVED CPISCITELLI
Note: Inspected trunkline and line sets. Made notes on plans.
ELECTRIC 2ND ROUGH 11/28/2023 APPROVED RMARTIN
Note: 11/9/2023 - PREVIOUS INSPECTION NOTES Walls only marked on print
PLUMBING 2ND ROUGH 11/20/2023 APPROVED - AS NOTED MGIBSON
Note: Inspector Notes from Inspection 3070 THIS WAS FOR WASTE,VENT WATER, ''COMPRESSED AIR'' AND VACCUUME LINES ALL ARE APPROVED ONE SIDE OF DRYWALL WAS INSTALLED BEFORE PLUMBER COUL INSTALL NAIL PLATES WILL BE DONE BY VIRTUAL INSPECTION ON ALL OPERATORIES
ELECTRIC 2ND ROUGH 11/13/2023 PARTIALLY APPROVED RMARTIN
Note: Walls only marked on print
FRAMING 11/13/2023 APPROVED FWILLIS
Note: INSPECTED 11/9/23 PER JOSH
CONCRETE FORM 10/27/2023 APPROVED FWILLIS
Note: 10/27/23 - ITEMS CORRECTED 10/26/2023 - PREVIOUS INSPECTION NOTES PLACEMENT OF PERMIT, 105.7 SHALL BE KEPT ON SITE DOCUMENTS MUST BE APPROVED AND KEPT ON SITE 107.3,1. AND SHALL BE OPEN TO INSPECTION BY THE BUILDING OFFICIAL. NO ONE ON SITE AT THE TIME OF MY VISIT.
CONCRETE FORM 10/26/2023 Disapproved -FEE REQUIRED FWILLIS
Note: PLACEMENT OF PERMIT, 105.7 SHALL BE KEPT ON SITE DOCUMENTS MUST BE APPROVED AND KEPT ON SITE 107.3,1. AND SHALL BE OPEN TO INSPECTION BY THE BUILDING OFFICIAL. NO ONE ON SITE AT THE TIME OF MY VISIT.
PLUMBING 1ST ROUGH 10/19/2023 APPROVED - AS NOTED MGIBSON
Note: THIS WAS FOR WASTE,VENT WATER, ''COMPRESSED AIR'' AND VACCUUME LINES ALL ARE APPROVED
ELECTRIC 1ST ROUGH 10/19/2023 APPROVED RMARTIN

Review History

Department Status Date In Date Out
ELEC COMPLETE 01/30/2024 02/02/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
BLD CANCEL 12/28/2023 01/02/2024
ELEC COMPLETE 12/28/2023 01/02/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
MECH COMPLETE 12/28/2023 01/09/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
PLUM COMPLETE 12/28/2023 01/12/2024
Note: Released By: PATRICK BUCKLEY - (386)986-3786 - PBUCKLEY@PALMCOASTGOV.COM
BLD COMPLETE 07/21/2023 07/25/2023
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
BADMIN COMPLETE 07/12/2023 07/12/2023
Note: Released By: LIBBY MUSGROVE - - LMUSGROVE@PALMCOASTGOV.COM
BADMIN HOLD 06/29/2023 06/29/2023
Note: Held By: BARBIE BEMBRY - (386)986-3780 - BUILDINGDIVISION@PALMCOASTGOV.COM Permit application to include general contractor and subcontractors to be submitted prior to issuance.
BADMIN COMPLETE 06/26/2023 06/26/2023
Note: Released By: MICHELLE RAMOS - - MRAMOS@PALMCOASTGOV.COM
BADMIN INFORMATION 06/26/2023 06/26/2023
Note: Marked INFORMATION By: MICHELLE RAMOS - - MRAMOS@PALMCOASTGOV.COM Permit application name needs to be under owner.
FI1 COMPLETE 06/05/2023 06/13/2023
Note: Released By: LEE MILLER - (386)986-3783 - WMILLER@PALMCOASTGOV.COM
DSD COMPLETE 06/05/2023 06/07/2023
Note: Released By: JACQUELINE GONZALEZ - (386)986-3751 - JGONZALEZ@PALMCOASTGOV.COM
ELEC COMPLETE 06/05/2023 06/06/2023
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
PLUM COMPLETE 06/05/2023 06/16/2023
Note: Released By: PATRICK BUCKLEY - (386)986-3786 - PBUCKLEY@PALMCOASTGOV.COM
BLD COMPLETE 06/05/2023 06/16/2023
Note: Released By: PATRICK BUCKLEY - (386)986-3786 - PBUCKLEY@PALMCOASTGOV.COM
BADMIN HOLD 04/26/2023 04/26/2023
Note: Held By: BARBIE BEMBRY - (386)986-3780 - BUILDINGDIVISION@PALMCOASTGOV.COM 1. Provide Florida licensed general or building contractor on permit application. Provide Florida licensed plumbing, mechanical and electrical contractors on permit application. 2. Plumbing contractor must be medical gas certified for work on dental compressed air and vacuum systems per FS 489.1136 91) (a). Provide copy of plumbing contractor’s medical gas certification. Individual actually performing work on compressed air and vacuum systems must also meet specific training requirements per FS 489.1136 (1) (b). Provide copy of current Certificate of Completion for required coursework / training.
DSD HOLD 04/12/2023 04/12/2023
Note: Held By: JACQUELINE GONZALEZ - (386)986-3751 - JGONZALEZ@PALMCOASTGOV.COM Revise Application to show units 106 and 107. These two units are being are now combined as one unit.
MECH COMPLETE 04/12/2023 04/13/2023
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
ELEC HOLD 04/12/2023 04/20/2023
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Outlets in patient rooms within 6 ft of a sink need to be GFCI protected. NEC 2017 210.8
FI1 HOLD 04/12/2023 04/26/2023
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM ** Please provide a written response to each comment below in a response letter and provide clouded response changes on plan sheets with page locations for each response.** 1. Please define category of facility per NFPA 99 (2018) chapter 15 for review (of correct category) (category 1, 2, or 3). (The Category must be noted by the owner or Design Professional). (Be sure to satisfy all the requirements of the correct category and related requirements of chapter 15 and include the needed information for the next review, additional comments are likely after resubmittal) Life safety plan needs to include all location of fire extinguishers and the actaul travel distance between them. 2. Please provide complete Life Safety Plan per FFPC I Fire Code 10.14.3.4.3 for review. 3. Please acknowledge, A note was placed on the permit indicating the need for separate permits for fire safety systems. 4. Please acknowledge, Fire protection pages received only a cursory review due to the fact they will be reviewed under separate permits. 2nd REQUEST
PLUM HOLD 04/12/2023 04/26/2023
Note: Held By: PATRICK BUCKLEY - (386)986-3786 - PBUCKLEY@PALMCOASTGOV.COM All comments below per the 2020 Florida Building Code-Plumbing Plan Sheet P400 1. REPEAT COMMENT: Change Contractor Note No. 1 to reference 2018 NFPA 99.
BLD HOLD 04/12/2023 04/26/2023
Note: Held By: PATRICK BUCKLEY - (386)986-3786 - PBUCKLEY@PALMCOASTGOV.COM All comments below per the 2020 Florida Building Code-Building (FBCB), Florida Building Code-Existing Building (FBCEB), Florida Building Code-Accessibility (FBCA) Florida Statutes (FS) and Florida Administrative Code (FAC). 3. REPEAT COMMENT: Permit application indicates expansion of existing dental facility. Please clarify. Is this tenant expanding into adjacent space, not previously occupied by tenant or are alterations occurring within existing tenant space only? If alterations are limited to existing tenant space, revise permit application to remove the term and / or any reference to "expansion" and / or similar language. Plan Sheet A000 2. REPEAT COMMENT: Provide FBCEB analysis of other required alterations, if any, based on the classification of work. Refer to the appropriate Sections for guidance. Provide design and details for any required additional alterations.
BADMIN COMPLETE 03/21/2023 03/21/2023
Note: Released By: PATRICK BUCKLEY - (386)986-3786 - PBUCKLEY@PALMCOASTGOV.COM Architect was authorized to submit permit without contractors and sub-contractors by me. Contractor and subs to be named prior to permit issuance.
BLD HOLD 03/02/2023 03/17/2023
Note: Held By: PATRICK BUCKLEY - (386)986-3786 - PBUCKLEY@PALMCOASTGOV.COM All comments below per the 2020 Florida Building Code-Building (FBCB), Florida Building Code-Existing Building (FBCEB), Florida Building Code-Accessibility (FBCA) Florida Statutes (FS) and Florida Administrative Code (FAC). General 1. Provide Florida licensed general or building contractor on permit application. Provide Florida licensed plumbing, mechanical and electrical contractors on permit application. This information does not have to be provided at re-submittal of plans but is required for issuance of the permit. 2. Plumbing contractor must be medical gas certified for work on dental compressed air and vacuum systems per FS 489.1136 91) (a). Provide copy of plumbing contractor’s medical gas certification. Individual actually performing work on compressed air and vacuum systems must also meet specific training requirements per FS 489.1136 (1) (b). Provide copy of current Certificate of Completion for required coursework / training. This information does not have to be provided at re-submittal of plans but is required for issuance of the permit. 3. Permit application indicates expansion of existing dental facility. Please clarify. Is this tenant expanding into adjacent space, not previously occupied by tenant or are alterations occurring within existing tenant space only? If alterations are limited to existing tenant space, revise permit application to remove the term and / or any reference to "expansion" and / or similar language. All Architectural Plan Sheets 1. Provide architect verifiable digital signature and seal – all plan sheets. FS 481.221, FAC 61G1-16.005. Docusign is not an approved verifiable digital signature. Plan Sheet A000 1. Provide classification of work per FBCEB Chapter 6 and define the alteration level per Sections 602 through 605. 2. Provide FBCEB analysis of other required alterations, if any, based on the classification of work. Refer to the appropriate Sections for guidance. Provide design and details for any required additional alterations. Plan Sheet A001 1. Remove references to assembly occupancy - there is no room or space within this tenant space that has an occupant load greater than 49 persons. Revise occupant load and required plumbing facilities and fixtures based on Group B - business uses /150 sq. ft. per occupant.
DSD HOLD 03/02/2023 03/03/2023
Note: Held By: JACQUELINE GONZALEZ - (386)986-3751 - JGONZALEZ@PALMCOASTGOV.COM Revise Application to show units 106 and 107. These two units are being are now combined as one unit.
ELEC HOLD 03/02/2023 03/14/2023
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Need to show that the new panel will have its proper workspace. NEC 2017 110.26 2. Riser diagram needs to show the wire sizes for the panel 3. All outlets need to be GFCI protected thats within 6 feet of the sinks. NEC 2017 210.8 4. Need emergency light in the panel room. NEC 2017 110.26 (D) 5. Disconnecting means for the x rays must comply with NEC 2017 660.5
FI1 HOLD 03/02/2023 03/15/2023
Note: Held By: LEE MILLER - (386)986-3783 - WMILLER@PALMCOASTGOV.COM All comments below per the 2020 Florida Fire Prevention Code. And or 2020 FBC Please provide a written response to each comment below in a response letter and provide clouded response changes on plan sheets with page locations for each response. 1. Please define category of facility per NFPA 99 (2018) chapter 15 for review (of correct category) (category 1, 2, or 3). (The Category must be noted by the owner or Design Professional). (Be sure to satisfy all the requirements of the correct category and related requirements of chapter 15 and include the needed information for the next review, additional comments are likely after resubmittal). 2. Please provide complete Life Safety Plan per FFPC I Fire Code 10.14.3.4.3 for review. 3. Please acknowledge, A note was placed on the permit indicating the need for separate permits for fire safety systems. 4. Please acknowledge, Fire protection pages received only a cursory review due to the fact they will be reviewed under separate permits.
MECH HOLD 03/02/2023 03/13/2023
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM 1. Provide code analysis showing level of alteration per chapter 6 FBC Existing Building 2020 7Th edition 2. Provide Heatload Calculation per C403.2.1 FBC Energy Conservation 2020 7Th edition 3. Provide Ventilation calculation per Table 403.3.1.1 FBC Mechanical 2020 7Th edition 4. Provide note on plan for test and balance per C408.2.2 FBC Energy Conservation 2020 7Th edition 5. Plan Sheet M300 shows AHU 1 and CU2. Provide clarification. Also provide details on existing 5 ton system 6. Plan sheet M200 need to show smoke detector on drawing for existing 5 ton system.
PLUM HOLD 03/02/2023 03/17/2023
Note: Held By: PATRICK BUCKLEY - (386)986-3786 - PBUCKLEY@PALMCOASTGOV.COM All comments below per the 2020 Florida Building Code-Plumbing (FBCP) Florida Statutes (FS) and Florida Administrative Code (FAC). General 1. Plumbing contractor must be medical gas certified for work on dental compressed air and vacuum systems per FS 489.1136 91) (a). Provide copy of plumbing contractor’s medical gas certification. Individual actually performing work on compressed air and vacuum systems must also meet specific training requirements per FS 489.1136 (1) (b). Provide copy of current Certificate of Completion for required coursework / training. This information does not have to be provided at re-submittal of plans but is required for issuance of the permit. Plan Sheet P000 1. Equipment Plumbing-Dental Compressed Air-Vac Schedule indicates potable water connection to sterilization cabinet and ultrasonic cleaner. Provide backflow preventer type, manufacturer, model and standard it must conform to. Section 608.3, Table 608.1. Does the side cabinet connection also require backflow protection? 2. Equipment Plumbing-Dental Compressed Air-Vac Schedule indicates sterilization cabinet to be direct connected to sanitary system. Change to indirect connection or provide details how sterilization cabinet complies with protection against backflow, flooding, fouling, contamination and stoppage of the drain. Section 801.2. 3. Specify backflow preventer location, type, manufacturer, model and standard it must conform to at connections to each dental pumping equipment system. Section 608.1.7.9. Plan Sheet P200 1. Show location of backflow preventers mentioned in comments for Plan Sheet P000 in plumbing riser diagram. Add keyed notes. Plan Sheet P300 1. Provide indirect waste receptor and piping details for discharge from sterilization cabinet and ultrasonic cleaner described on Plan Sheet P000. Provide keyed notes. Section 801.2. Plan Sheet P400 1. Change Contractor Note No. 1 to reference 2018 NFPA 99.
UD1 COMPLETE 03/02/2023 03/03/2023
Note: Released By: BRICE WRIGHT - -
BADMIN HOLD 03/02/2023 03/02/2023
Note: Held By: BARBIE BEMBRY - (386)986-3780 - BUILDINGDIVISION@PALMCOASTGOV.COM Permit application to include general contractor and subcontractors to be submitted prior to issuance.

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION- SITE INSPECTOR ¤40.00 10/26/2023
SURCHARGE FS 533.721 ¤14.64 07/25/2023
SURCHARGE - FS 468.631 ¤21.96 07/25/2023
SITE PLAN 30 ¤30.00 07/25/2023
ADJUSTMENT 50% (¤1,463.75) 07/25/2023
ADMINISTRATIVE - COMMERCIAL ¤75.00 07/25/2023
INSPECTION COMMERCIAL ¤2,450.00 07/25/2023
PLAN REVIEW - COMMERCIAL ¤402.50 07/25/2023
Fees Total Due: ¤0.00 Total Paid: ¤1,570.35