I want to search for...
Permit #2023030269
Permit Details
Status: COED
| Parcel Id: 07-11-31-7022-00330-0330 |
| CONDITIONED SPACE: 2295 sqft |
| GARAGE: 538 sqft |
| OPENED PORCH (WITH ROOF) : 201 sqft |
| OPENED PORCH (WITH ROOF) : 229 sqft |
| Total Square Footage: 3263 sqft |
| Block: 00330 |
| Subdivision: 2217 - SECTION 22-WYNNFIELD |
| Job Phone: 912-258-2201 |
| Location Address: 66 WESTHAMPTON DR |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 04/27/2023 |
| NOC: RECORDED |
| Applicant name: JAMES FUCETOLA III |
| Owner: PALM COAST COMMUNITIES LLC |
|
Address PO BOX 22547 ST SIMONS ISLAND, GA 31522 |
| Lot: 0330 |
| Contracted Stated Job Value: ¤195,000.00 |
| Job Description: Single Family Residence |
| Type: CN |
Contractor
PALM COAST COMMUNITIES LLC
| Status | Location Address | State License Number | Phone |
| INACTIVE |
PO BOX 22547 PALM COAST, FL 32164 |
CBC1262878 (Exp: 08/31/2026) | 321-501-4617 |
Sub Contractors
JEFFREY TROY SABAKA
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
2191 DEERWOOD ACRES DR ST AUGUSTINE, FL 32084 |
CFC1427439 (Exp: 08/31/2026) | 904-838-2218 | 904-819-0965 |
WILLIAM FRANK DUDLEY JR.
| Status | Location Address | State License Number | Phone |
| ACTIVE |
P.O. BOX 978 Bunnell, FL 32110 |
EC0003177 (Exp: 08/31/2026) | (386)437-3068 |
OLEG BELINSKIY
| Status | Location Address | State License Number | Phone |
| ACTIVE |
19 PINE CIRCLE DRIVE19 PALM COAST, FL 32167 |
CCC1325974 (Exp: 08/31/2026) | 386-263-7906 |
GARY LLOYD SHEFFIELD
| Status | Location Address | State License Number | Phone |
| ACTIVE |
48 EAGLE LAKES DRIVE FLAGLER BEACH, FL 32136 |
CAC048127 (Exp: 08/31/2026) | 386-597-3280 |
Inspection History
| Type | Request Date | Result | Inspector |
| BLD - BUILDING FINAL | 01/05/2024 | FINAL APPROVED | MKRASKI |
| Note: | |||
| U-CROSS CONNECTION | 12/22/2023 | APPROVED - AS NOTED | LFITZGERALD |
| Note: has potable irr with DBL HECK-no cross connection | |||
| BLD - BUILDING FINAL | 12/22/2023 | Disapproved - NO FEE | MKRASKI |
| Note: 1. Hose bib anti back flows require a shear screw to be installed 2. E-cals do not match equipment installed please submitt a revision and have it approved by Building Dept. before re-inspection 3. Exposed romex by meter | |||
| U -UTILITY RESIDENTIAL FINAL | 12/22/2023 | FINAL APPROVED | LFITZGERALD |
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 12/21/2023 | APPROVED | TPOLACEK |
| Note: 12/21/23 ** UPON WALKING PROPERTY DRAINAGE WILL WORK AS INDICATED ON FINAL SURVEY. AT THE TIME FROM THE TIME OF THE INSPECTION OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. | |||
| ROW FIELD SURVEY /GRADING CERTIFICATION | 12/21/2023 | APPROVED - AS NOTED | TPOLACEK |
| Note: 12/21/23 THERE IS DIRT/SILT IN LEFT SIDE SWALE FROM BUILDERS LOT ON LEFT. I WILL APPROVE AS NOTED. AT THE TIME FROM THE TIME OF THE INSPECTION OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. | |||
| ROW - STORMWATER FINAL | 12/21/2023 | APPROVED | TPOLACEK |
| Note: 12/21/23 AT THE TIME FROM THE TIME OF THE INSPECTION OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. Inspector Notes from Inspection 9465 12/21/23 THERE IS DIRT/SILT IN LEFT SIDE SWALE FROM BUILDERS LOT ON LEFT. I WILL APPROVE AS NOTED. AT THE TIME FROM THE TIME OF THE INSPECTION OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. | |||
| ROW - FINAL APRON (AFTER POUR) | 12/21/2023 | APPROVED | TPOLACEK |
| Note: Inspector Notes from Inspection 9465 12/21/23 THERE IS DIRT/SILT IN LEFT SIDE SWALE FROM BUILDERS LOT ON LEFT. I WILL APPROVE AS NOTED. AT THE TIME FROM THE TIME OF THE INSPECTION OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. | |||
| U - SEWER TIE IN | 11/21/2023 | APPROVED - AS NOTED | MGIBSON |
| Note: THIS WAS A VIRTUAL INSPECTION | |||
| ROW- PRE-APRON (PRE-POUR) | 11/16/2023 | APPROVED | PFLANAGAN |
| Note: IT'S YOUR RESPONSIBILITY TO CHECK THE CULVERT ELEVATIONS BEFORE POURING CONCRETE ALL CONCRETE NEEDS TO BE A MINIMUM OF 3000PSI WITH FIBER OR WITH METAL MESH IN THE CONCRETE TO MEET ALL CITY'S STANDARDS At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved. | |||
| ELECTRIC - EARLY POWER | 11/09/2023 | APPROVED - AS NOTED | MKRASKI |
| Note: Emailed FPL @ 2:10PM | |||
| INSULATION | 10/11/2023 | APPROVED | MKRASKI |
| INSULATION | 10/10/2023 | Disapproved - NO FEE | MKRASKI |
| Note: 1. Garage wood frame wall needs to be sealed at edges 2. Exhaust fan ducts are required to be supported min. of every 4' | |||
| ALL ROUGH | 10/05/2023 | APPROVED - AS NOTED | BTAYLOR |
| Note: 10-5-23 1. Window in master bedroom is broken. | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 10/04/2023 | APPROVED | MKRASKI |
| Note: 10/2/2023 - PREVIOUS INSPECTION NOTES 10/2/23 1. Engineered letter for missed truss straps has accepted but not been approved by Building Dept. 2. No truss layout on site 3. Need full set of truss engineering packet on site Did not check truss strapping or truss engineering 9/12/2023 - PREVIOUS INSPECTION NOTES 9/12/23 1. Load bearing door opening not per detail (Detail is also required to be onsite for inspection) 2. Garage door bucks not installed per detail 3.Missed truss straps are over allowable number. Will need a engineered repair for missed straps submitted to Building Dept. and approved. Documents need to be onsite for inspection 4. Address is not visible from road Stopped inspection not ready, Walk job site before calling in for inspection 8/14/2023 - PREVIOUS INSPECTION NOTES 8/14/23 All corrections need to be corrected before calling in re-imspection, stopped inspection 8/9/2023 - PREVIOUS INSPECTION NOTES 1. Trade work shall not begin untill after this inspection has been passed 2. No door opening deatil for load bearing walls 3. Full set of plans that are not damaged need to be on site for inspector 4. Garage door bucks not installed Stopped inspection | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 10/02/2023 | Disapproved -FEE REQUIRED | MKRASKI |
| Note: 10/2/23 1. Engineered letter for missed truss straps has accepted but not been approved by Building Dept. 2. No truss layout on site 3. Need full set of truss engineering packet on site Did not check truss strapping or truss engineering 9/12/2023 - PREVIOUS INSPECTION NOTES 9/12/23 1. Load bearing door opening not per detail (Detail is also required to be onsite for inspection) 2. Garage door bucks not installed per detail 3.Missed truss straps are over allowable number. Will need a engineered repair for missed straps submitted to Building Dept. and approved. Documents need to be onsite for inspection 4. Address is not visible from road Stopped inspection not ready, Walk job site before calling in for inspection 8/14/2023 - PREVIOUS INSPECTION NOTES 8/14/23 All corrections need to be corrected before calling in re-imspection, stopped inspection 8/9/2023 - PREVIOUS INSPECTION NOTES 1. Trade work shall not begin untill after this inspection has been passed 2. No door opening deatil for load bearing walls 3. Full set of plans that are not damaged need to be on site for inspector 4. Garage door bucks not installed Stopped inspection | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 09/12/2023 | Disapproved -FEE REQUIRED | MKRASKI |
| Note: 9/12/23 1. Load bearing door opening not per detail (Detail is also required to be onsite for inspection) 2. Garage door bucks not installed per detail 3.Missed truss straps are over allowable number. Will need a engineered repair for missed straps submitted to Building Dept. and approved. Documents need to be onsite for inspection 4. Address is not visible from road Stopped inspection not ready, Walk job site before calling in for inspection 8/14/2023 - PREVIOUS INSPECTION NOTES 8/14/23 All corrections need to be corrected before calling in re-imspection, stopped inspection 8/9/2023 - PREVIOUS INSPECTION NOTES 1. Trade work shall not begin untill after this inspection has been passed 2. No door opening deatil for load bearing walls 3. Full set of plans that are not damaged need to be on site for inspector 4. Garage door bucks not installed Stopped inspection | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 08/14/2023 | Disapproved -FEE REQUIRED | MKRASKI |
| Note: 8/14/23 All corrections need to be corrected before calling in re-imspection, stopped inspection 8/9/2023 - PREVIOUS INSPECTION NOTES 1. Trade work shall not begin untill after this inspection has been passed 2. No door opening deatil for load bearing walls 3. Full set of plans that are not damaged need to be on site for inspector 4. Garage door bucks not installed Stopped inspection | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 08/09/2023 | Disapproved -FEE REQUIRED | MKRASKI |
| Note: 1. Trade work shall not begin untill after this inspection has been passed 2. No door opening deatil for load bearing walls 3. Full set of plans that are not damaged need to be on site for inspector 4. Garage door bucks not installed Stopped inspection | |||
| LATH/BRICK/ WATER BARRIER | 08/07/2023 | APPROVED | MKRASKI |
| ROOF VALLEY & METAL | 07/25/2023 | APPROVED | MKRASKI |
| WALL SHEATHING | 07/20/2023 | APPROVED | MKRASKI |
| ROOF SHEATHING | 07/18/2023 | APPROVED | MKRASKI |
| TIE BEAM / LINTEL | 07/12/2023 | APPROVED | MKRASKI |
| Note: 7/10/2023 - PREVIOUS INSPECTION NOTES 7/10/23 BED JOINT ON SILLS, HIGHLIGHTED IN ORANGE, EXCEED BUILDING CODE TOLERANCE. R606.3.1, FBC106.4 - 3/8". 7/7/2023 - PREVIOUS INSPECTION NOTES 7/5/2023 - PREVIOUS INSPECTION NOTES 6/27/2023 - PREVIOUS INSPECTION NOTES 1. Block over hanging slab on front wall right onf entry 7/5/23 - BED JOINT ON SILLS, HIGHLIGHTED IN ORANGE, EXCEED BUILDING CODE TOLERANCE. R606.3.1, FBC106.4 - 3/8". | |||
| TIE BEAM / LINTEL | 07/10/2023 | Disapproved -FEE REQUIRED | MKRASKI |
| Note: 7/10/23 BED JOINT ON SILLS, HIGHLIGHTED IN ORANGE, EXCEED BUILDING CODE TOLERANCE. R606.3.1, FBC106.4 - 3/8". 7/7/2023 - PREVIOUS INSPECTION NOTES 7/5/2023 - PREVIOUS INSPECTION NOTES 6/27/2023 - PREVIOUS INSPECTION NOTES 1. Block over hanging slab on front wall right onf entry 7/5/23 - BED JOINT ON SILLS, HIGHLIGHTED IN ORANGE, EXCEED BUILDING CODE TOLERANCE. R606.3.1, FBC106.4 - 3/8". | |||
| TIE BEAM / LINTEL | 07/07/2023 | CANCELLED BY APPLICANT | MKRASKI |
| Note: 7/5/2023 - PREVIOUS INSPECTION NOTES 6/27/2023 - PREVIOUS INSPECTION NOTES 1. Block over hanging slab on front wall right onf entry 7/5/23 - BED JOINT ON SILLS, HIGHLIGHTED IN ORANGE, EXCEED BUILDING CODE TOLERANCE. R606.3.1, FBC106.4 - 3/8". | |||
| LATH/BRICK/ WATER BARRIER | 07/05/2023 | Disapproved - NO FEE | FWILLIS |
| Note: NO LATH INSTALLED WRONG INSPECTION. | |||
| TIE BEAM / LINTEL | 07/05/2023 | Disapproved -FEE REQUIRED | FWILLIS |
| Note: 6/27/2023 - PREVIOUS INSPECTION NOTES 1. Block over hanging slab on front wall right onf entry 7/5/23 - BED JOINT ON SILLS, HIGHLIGHTED IN ORANGE, EXCEED BUILDING CODE TOLERANCE. R606.3.1, FBC106.4 - 3/8". | |||
| FOUND SURVEY APPROVED (OFFICE) | 07/05/2023 | APPROVED | TBAKER |
| TIE BEAM / LINTEL | 06/27/2023 | Disapproved - NO FEE | MKRASKI |
| Note: 1. Block over hanging slab on front wall right onf entry | |||
| MONOLITHIC SLAB | 06/14/2023 | APPROVED | MKRASKI |
| PLUMBING 1ST ROUGH UNDERGROUND | 06/09/2023 | APPROVED | MKRASKI |
| GRAVITY SEWER TEST | 06/09/2023 | APPROVED | MKRASKI |
| WATER METER INSTALLATION REQUEST | 05/15/2023 | APPROVED | CSTONE |
Review History
| Department | Status | Date In | Date Out |
| MECH | COMPLETE | 12/27/2023 | 01/04/2024 |
| Note: Released By: PATRICK BUCKLEY - (386)986-3786 - PBUCKLEY@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 09/29/2023 | 10/02/2023 |
| Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM NO new site plan submitted. This was done in error | |||
| SW1 | COMPLETE | 09/29/2023 | 10/02/2023 |
| Note: Released By: GABRIEL BERTOLA - (386)986-7660 - GBERTOLA@PALMCOASTGOV.COM | |||
| ZON | HOLD | 09/22/2023 | 09/22/2023 |
| Note: Held By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM REPEAT COMMENT: Incorrect Site plan Submitted. Please submit the correct plan | |||
| SW1 | HOLD | 09/22/2023 | 09/25/2023 |
| Note: Held By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM NEED TO HAVE 10' OFF SET ELEVATIONS BEHIND YOUR BACK PROPOERTY LINE SO WE CAN DETERMINE IF DRAINAGE WILL WORK CORRECTLY | |||
| BLD | COMPLETE | 09/22/2023 | 09/26/2023 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 09/13/2023 | 09/13/2023 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| SW1 | HOLD | 09/13/2023 | 09/20/2023 |
| Note: Held By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM NEED TO HAVE EXISTING ELEVATION 10' OFF THE BACK PEOPERTY LINE SO WE CAN DETERMINE IF THE DRAINAGE WILL FLOW IN TO DRAINAGE BEHIND YOUR LOT | |||
| ZON | HOLD | 09/13/2023 | 09/13/2023 |
| Note: Held By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM Incorrect Site plan Submitted. PLease submit the correct plan | |||
| BLD | COMPLETE | 09/01/2023 | 09/11/2023 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 07/13/2023 | 07/17/2023 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 07/05/2023 | 07/05/2023 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 07/05/2023 | 07/05/2023 |
| Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM | |||
| ELEC | COMPLETE | 04/17/2023 | 04/20/2023 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 04/04/2023 | 04/04/2023 |
| Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM | |||
| ELEC | HOLD | 04/04/2023 | 04/05/2023 |
| Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Need correct outlet spacing NEC 2017 210.52 Master bed switch wall. | |||
| ENGIN1 | COMPLETE | 04/04/2023 | 04/05/2023 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 04/04/2023 | 04/12/2023 |
| Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM | |||
| ENGIN1 | HOLD | 03/20/2023 | 03/20/2023 |
| Note: Held By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM Survey elevations differ form COPC GPS and ITT as-builts by .7'+/- | |||
| SWALE | COMPLETE | 03/07/2023 | 05/24/2023 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 03/06/2023 | 03/11/2023 |
| Note: Released By: JPI | |||
| CUSVC | COMPLETE | 03/06/2023 | 03/08/2023 |
| Note: Released By: LISA ASBILL - - lasbill@palmcoastgov.com | |||
| ELEC | HOLD | 03/06/2023 | 03/07/2023 |
| Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Need correct outlet spacing NEC 2017 210.52 (Master Bed) | |||
| ENGIN1 | COMPLETE | 03/06/2023 | 03/07/2023 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| GAS | CANCEL | 03/06/2023 | 03/07/2023 |
| Note: not needed | |||
| LOCATE | COMPLETE | 03/06/2023 | 03/13/2023 |
| Note: Released By: CANDACE STONE - - CSTONE@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 03/06/2023 | 03/07/2023 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 03/06/2023 | 03/13/2023 |
| Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM | |||
| ZON | HOLD | 03/06/2023 | 03/07/2023 |
| Note: Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM Need one additional tree for this lot size | |||
| BADMIN | COMPLETE | 03/06/2023 | 03/12/2023 |
| Note: Released By: BARBIE BEMBRY - (386)986-3780 - BUILDINGDIVISION@PALMCOASTGOV.COM |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| PLAN REVIEW - REVISION | ¤32.50 | 01/05/2024 |
| PLAN REVIEW - REVISION | ¤32.50 | 01/05/2024 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 01/05/2024 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 01/05/2024 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 01/05/2024 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 01/05/2024 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 01/05/2024 |
| CONNECTION FEES | ¤1,166.26 | 04/27/2023 |
| FIRE IMPACT FEE ADMIN | ¤12.62 | 04/27/2023 |
| FIRE IMPACT FEE ADMIN | (¤12.62) | 04/27/2023 |
| FC IMPACT FEE EMS | ¤62.00 | 04/27/2023 |
| IMPACT FEE FIRE | ¤420.52 | 04/27/2023 |
| FC IMPACT FEE LAW ENFORCEMENT | ¤218.00 | 04/27/2023 |
| FC IMPACT FEE LIBRARY | ¤268.00 | 04/27/2023 |
| IMPACT FEE PARKS | ¤1,769.15 | 04/27/2023 |
| IMPACT FEE SCHOOL | ¤5,450.00 | 04/27/2023 |
| IMPACT FEE TRANSPORTATION | ¤1,812.00 | 04/27/2023 |
| WATER -IRRIGATION INSPECTION | ¤25.00 | 04/27/2023 |
| PARKS IMPACT FEE ADMIN | ¤53.07 | 04/27/2023 |
| PARKS IMPACT FEE ADMIN | (¤53.07) | 04/27/2023 |
| SURCHARGE FS 533.721 | ¤3.43 | 04/27/2023 |
| SURCHARGE - FS 468.631 | ¤5.15 | 04/27/2023 |
| SW ENG - FOUNDATION SURVEY | ¤20.00 | 04/27/2023 |
| SW ENG INSPECTION 80 | ¤80.00 | 04/27/2023 |
| SW ENG PRE APRON | ¤30.00 | 04/27/2023 |
| SW ENG - REVIEW 20 | ¤20.00 | 04/27/2023 |
| SW ENG RES REVIEW 200 | ¤200.00 | 04/27/2023 |
| TRANS IMPACT FEE ADMIN | ¤54.36 | 04/27/2023 |
| TRANS IMPACT FEE ADMIN | (¤54.36) | 04/27/2023 |
| SEWER INSPECTION | ¤25.00 | 04/27/2023 |
| SEWER CAPITAL FACILITY | ¤5,344.82 | 04/27/2023 |
| WATER CAPITAL FACILITY FEE | ¤3,923.88 | 04/27/2023 |
| SITE PLAN 30 | ¤30.00 | 04/27/2023 |
| WATER- TURN ON | ¤25.00 | 04/27/2023 |
| ADJUSTMENT 50% | (¤533.91) | 04/27/2023 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 04/27/2023 |
| INSPECTION - RESIDENTIAL | ¤808.50 | 04/27/2023 |
| PLAN REVIEW - RESIDENTIAL | ¤229.32 | 04/27/2023 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤21,697.12 |