Permit #2023030269

Permit Details

Status: COED

Parcel Id: 07-11-31-7022-00330-0330
CONDITIONED SPACE: 2295 sqft
GARAGE: 538 sqft
OPENED PORCH (WITH ROOF) : 201 sqft
OPENED PORCH (WITH ROOF) : 229 sqft
Total Square Footage: 3263 sqft
Block: 00330
Subdivision: 2217 - SECTION 22-WYNNFIELD
Job Phone: 912-258-2201
Location Address: 66 WESTHAMPTON DR
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 04/27/2023
NOC: RECORDED
Applicant name: JAMES FUCETOLA III
Owner: PALM COAST COMMUNITIES LLC

Address

PO BOX 22547

ST SIMONS ISLAND, GA 31522

Lot: 0330
Contracted Stated Job Value: ¤195,000.00
Job Description: Single Family Residence
Type: CN

Contractor

PALM COAST COMMUNITIES LLC
Status Location Address State License Number Phone
INACTIVE

PO BOX 22547

PALM COAST, FL 32164

CBC1262878 (Exp: 08/31/2026) 321-501-4617

Sub Contractors

JEFFREY TROY SABAKA
Status Location Address State License Number Phone Fax
ACTIVE

2191 DEERWOOD ACRES DR

ST AUGUSTINE, FL 32084

CFC1427439 (Exp: 08/31/2026) 904-838-2218 904-819-0965
WILLIAM FRANK DUDLEY JR.
Status Location Address State License Number Phone
ACTIVE

P.O. BOX 978

Bunnell, FL 32110

EC0003177 (Exp: 08/31/2026) (386)437-3068
OLEG BELINSKIY
Status Location Address State License Number Phone
ACTIVE

19 PINE CIRCLE DRIVE19

PALM COAST, FL 32167

CCC1325974 (Exp: 08/31/2026) 386-263-7906
GARY LLOYD SHEFFIELD
Status Location Address State License Number Phone
ACTIVE

48 EAGLE LAKES DRIVE

FLAGLER BEACH, FL 32136

CAC048127 (Exp: 08/31/2026) 386-597-3280

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 01/05/2024 FINAL APPROVED MKRASKI
Note:
U-CROSS CONNECTION 12/22/2023 APPROVED - AS NOTED LFITZGERALD
Note: has potable irr with DBL HECK-no cross connection
BLD - BUILDING FINAL 12/22/2023 Disapproved - NO FEE MKRASKI
Note: 1. Hose bib anti back flows require a shear screw to be installed 2. E-cals do not match equipment installed please submitt a revision and have it approved by Building Dept. before re-inspection 3. Exposed romex by meter
U -UTILITY RESIDENTIAL FINAL 12/22/2023 FINAL APPROVED LFITZGERALD
ROW- FINAL SURVEY/GRADING CERTIFICATION 12/21/2023 APPROVED TPOLACEK
Note: 12/21/23 ** UPON WALKING PROPERTY DRAINAGE WILL WORK AS INDICATED ON FINAL SURVEY. AT THE TIME FROM THE TIME OF THE INSPECTION OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED.
ROW FIELD SURVEY /GRADING CERTIFICATION 12/21/2023 APPROVED - AS NOTED TPOLACEK
Note: 12/21/23 THERE IS DIRT/SILT IN LEFT SIDE SWALE FROM BUILDERS LOT ON LEFT. I WILL APPROVE AS NOTED. AT THE TIME FROM THE TIME OF THE INSPECTION OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED.
ROW - STORMWATER FINAL 12/21/2023 APPROVED TPOLACEK
Note: 12/21/23 AT THE TIME FROM THE TIME OF THE INSPECTION OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. Inspector Notes from Inspection 9465 12/21/23 THERE IS DIRT/SILT IN LEFT SIDE SWALE FROM BUILDERS LOT ON LEFT. I WILL APPROVE AS NOTED. AT THE TIME FROM THE TIME OF THE INSPECTION OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED.
ROW - FINAL APRON (AFTER POUR) 12/21/2023 APPROVED TPOLACEK
Note: Inspector Notes from Inspection 9465 12/21/23 THERE IS DIRT/SILT IN LEFT SIDE SWALE FROM BUILDERS LOT ON LEFT. I WILL APPROVE AS NOTED. AT THE TIME FROM THE TIME OF THE INSPECTION OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED.
U - SEWER TIE IN 11/21/2023 APPROVED - AS NOTED MGIBSON
Note: THIS WAS A VIRTUAL INSPECTION
ROW- PRE-APRON (PRE-POUR) 11/16/2023 APPROVED PFLANAGAN
Note: IT'S YOUR RESPONSIBILITY TO CHECK THE CULVERT ELEVATIONS BEFORE POURING CONCRETE ALL CONCRETE NEEDS TO BE A MINIMUM OF 3000PSI WITH FIBER OR WITH METAL MESH IN THE CONCRETE TO MEET ALL CITY'S STANDARDS At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved.
ELECTRIC - EARLY POWER 11/09/2023 APPROVED - AS NOTED MKRASKI
Note: Emailed FPL @ 2:10PM
INSULATION 10/11/2023 APPROVED MKRASKI
INSULATION 10/10/2023 Disapproved - NO FEE MKRASKI
Note: 1. Garage wood frame wall needs to be sealed at edges 2. Exhaust fan ducts are required to be supported min. of every 4'
ALL ROUGH 10/05/2023 APPROVED - AS NOTED BTAYLOR
Note: 10-5-23 1. Window in master bedroom is broken.
ROOF SHEATHING / BRACES/TIES/DOWN CELL 10/04/2023 APPROVED MKRASKI
Note: 10/2/2023 - PREVIOUS INSPECTION NOTES 10/2/23 1. Engineered letter for missed truss straps has accepted but not been approved by Building Dept. 2. No truss layout on site 3. Need full set of truss engineering packet on site Did not check truss strapping or truss engineering 9/12/2023 - PREVIOUS INSPECTION NOTES 9/12/23 1. Load bearing door opening not per detail (Detail is also required to be onsite for inspection) 2. Garage door bucks not installed per detail 3.Missed truss straps are over allowable number. Will need a engineered repair for missed straps submitted to Building Dept. and approved. Documents need to be onsite for inspection 4. Address is not visible from road Stopped inspection not ready, Walk job site before calling in for inspection 8/14/2023 - PREVIOUS INSPECTION NOTES 8/14/23 All corrections need to be corrected before calling in re-imspection, stopped inspection 8/9/2023 - PREVIOUS INSPECTION NOTES 1. Trade work shall not begin untill after this inspection has been passed 2. No door opening deatil for load bearing walls 3. Full set of plans that are not damaged need to be on site for inspector 4. Garage door bucks not installed Stopped inspection
ROOF SHEATHING / BRACES/TIES/DOWN CELL 10/02/2023 Disapproved -FEE REQUIRED MKRASKI
Note: 10/2/23 1. Engineered letter for missed truss straps has accepted but not been approved by Building Dept. 2. No truss layout on site 3. Need full set of truss engineering packet on site Did not check truss strapping or truss engineering 9/12/2023 - PREVIOUS INSPECTION NOTES 9/12/23 1. Load bearing door opening not per detail (Detail is also required to be onsite for inspection) 2. Garage door bucks not installed per detail 3.Missed truss straps are over allowable number. Will need a engineered repair for missed straps submitted to Building Dept. and approved. Documents need to be onsite for inspection 4. Address is not visible from road Stopped inspection not ready, Walk job site before calling in for inspection 8/14/2023 - PREVIOUS INSPECTION NOTES 8/14/23 All corrections need to be corrected before calling in re-imspection, stopped inspection 8/9/2023 - PREVIOUS INSPECTION NOTES 1. Trade work shall not begin untill after this inspection has been passed 2. No door opening deatil for load bearing walls 3. Full set of plans that are not damaged need to be on site for inspector 4. Garage door bucks not installed Stopped inspection
ROOF SHEATHING / BRACES/TIES/DOWN CELL 09/12/2023 Disapproved -FEE REQUIRED MKRASKI
Note: 9/12/23 1. Load bearing door opening not per detail (Detail is also required to be onsite for inspection) 2. Garage door bucks not installed per detail 3.Missed truss straps are over allowable number. Will need a engineered repair for missed straps submitted to Building Dept. and approved. Documents need to be onsite for inspection 4. Address is not visible from road Stopped inspection not ready, Walk job site before calling in for inspection 8/14/2023 - PREVIOUS INSPECTION NOTES 8/14/23 All corrections need to be corrected before calling in re-imspection, stopped inspection 8/9/2023 - PREVIOUS INSPECTION NOTES 1. Trade work shall not begin untill after this inspection has been passed 2. No door opening deatil for load bearing walls 3. Full set of plans that are not damaged need to be on site for inspector 4. Garage door bucks not installed Stopped inspection
ROOF SHEATHING / BRACES/TIES/DOWN CELL 08/14/2023 Disapproved -FEE REQUIRED MKRASKI
Note: 8/14/23 All corrections need to be corrected before calling in re-imspection, stopped inspection 8/9/2023 - PREVIOUS INSPECTION NOTES 1. Trade work shall not begin untill after this inspection has been passed 2. No door opening deatil for load bearing walls 3. Full set of plans that are not damaged need to be on site for inspector 4. Garage door bucks not installed Stopped inspection
ROOF SHEATHING / BRACES/TIES/DOWN CELL 08/09/2023 Disapproved -FEE REQUIRED MKRASKI
Note: 1. Trade work shall not begin untill after this inspection has been passed 2. No door opening deatil for load bearing walls 3. Full set of plans that are not damaged need to be on site for inspector 4. Garage door bucks not installed Stopped inspection
LATH/BRICK/ WATER BARRIER 08/07/2023 APPROVED MKRASKI
ROOF VALLEY & METAL 07/25/2023 APPROVED MKRASKI
WALL SHEATHING 07/20/2023 APPROVED MKRASKI
ROOF SHEATHING 07/18/2023 APPROVED MKRASKI
TIE BEAM / LINTEL 07/12/2023 APPROVED MKRASKI
Note: 7/10/2023 - PREVIOUS INSPECTION NOTES 7/10/23 BED JOINT ON SILLS, HIGHLIGHTED IN ORANGE, EXCEED BUILDING CODE TOLERANCE. R606.3.1, FBC106.4 - 3/8". 7/7/2023 - PREVIOUS INSPECTION NOTES 7/5/2023 - PREVIOUS INSPECTION NOTES 6/27/2023 - PREVIOUS INSPECTION NOTES 1. Block over hanging slab on front wall right onf entry 7/5/23 - BED JOINT ON SILLS, HIGHLIGHTED IN ORANGE, EXCEED BUILDING CODE TOLERANCE. R606.3.1, FBC106.4 - 3/8".
TIE BEAM / LINTEL 07/10/2023 Disapproved -FEE REQUIRED MKRASKI
Note: 7/10/23 BED JOINT ON SILLS, HIGHLIGHTED IN ORANGE, EXCEED BUILDING CODE TOLERANCE. R606.3.1, FBC106.4 - 3/8". 7/7/2023 - PREVIOUS INSPECTION NOTES 7/5/2023 - PREVIOUS INSPECTION NOTES 6/27/2023 - PREVIOUS INSPECTION NOTES 1. Block over hanging slab on front wall right onf entry 7/5/23 - BED JOINT ON SILLS, HIGHLIGHTED IN ORANGE, EXCEED BUILDING CODE TOLERANCE. R606.3.1, FBC106.4 - 3/8".
TIE BEAM / LINTEL 07/07/2023 CANCELLED BY APPLICANT MKRASKI
Note: 7/5/2023 - PREVIOUS INSPECTION NOTES 6/27/2023 - PREVIOUS INSPECTION NOTES 1. Block over hanging slab on front wall right onf entry 7/5/23 - BED JOINT ON SILLS, HIGHLIGHTED IN ORANGE, EXCEED BUILDING CODE TOLERANCE. R606.3.1, FBC106.4 - 3/8".
LATH/BRICK/ WATER BARRIER 07/05/2023 Disapproved - NO FEE FWILLIS
Note: NO LATH INSTALLED WRONG INSPECTION.
TIE BEAM / LINTEL 07/05/2023 Disapproved -FEE REQUIRED FWILLIS
Note: 6/27/2023 - PREVIOUS INSPECTION NOTES 1. Block over hanging slab on front wall right onf entry 7/5/23 - BED JOINT ON SILLS, HIGHLIGHTED IN ORANGE, EXCEED BUILDING CODE TOLERANCE. R606.3.1, FBC106.4 - 3/8".
FOUND SURVEY APPROVED (OFFICE) 07/05/2023 APPROVED TBAKER
TIE BEAM / LINTEL 06/27/2023 Disapproved - NO FEE MKRASKI
Note: 1. Block over hanging slab on front wall right onf entry
MONOLITHIC SLAB 06/14/2023 APPROVED MKRASKI
PLUMBING 1ST ROUGH UNDERGROUND 06/09/2023 APPROVED MKRASKI
GRAVITY SEWER TEST 06/09/2023 APPROVED MKRASKI
WATER METER INSTALLATION REQUEST 05/15/2023 APPROVED CSTONE

Review History

Department Status Date In Date Out
MECH COMPLETE 12/27/2023 01/04/2024
Note: Released By: PATRICK BUCKLEY - (386)986-3786 - PBUCKLEY@PALMCOASTGOV.COM
ZON COMPLETE 09/29/2023 10/02/2023
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM NO new site plan submitted. This was done in error
SW1 COMPLETE 09/29/2023 10/02/2023
Note: Released By: GABRIEL BERTOLA - (386)986-7660 - GBERTOLA@PALMCOASTGOV.COM
ZON HOLD 09/22/2023 09/22/2023
Note: Held By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM REPEAT COMMENT: Incorrect Site plan Submitted. Please submit the correct plan
SW1 HOLD 09/22/2023 09/25/2023
Note: Held By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM NEED TO HAVE 10' OFF SET ELEVATIONS BEHIND YOUR BACK PROPOERTY LINE SO WE CAN DETERMINE IF DRAINAGE WILL WORK CORRECTLY
BLD COMPLETE 09/22/2023 09/26/2023
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
ENGIN1 COMPLETE 09/13/2023 09/13/2023
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
SW1 HOLD 09/13/2023 09/20/2023
Note: Held By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM NEED TO HAVE EXISTING ELEVATION 10' OFF THE BACK PEOPERTY LINE SO WE CAN DETERMINE IF THE DRAINAGE WILL FLOW IN TO DRAINAGE BEHIND YOUR LOT
ZON HOLD 09/13/2023 09/13/2023
Note: Held By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM Incorrect Site plan Submitted. PLease submit the correct plan
BLD COMPLETE 09/01/2023 09/11/2023
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
BLD COMPLETE 07/13/2023 07/17/2023
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ENGIN1 COMPLETE 07/05/2023 07/05/2023
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON COMPLETE 07/05/2023 07/05/2023
Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM
ELEC COMPLETE 04/17/2023 04/20/2023
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ZON COMPLETE 04/04/2023 04/04/2023
Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM
ELEC HOLD 04/04/2023 04/05/2023
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Need correct outlet spacing NEC 2017 210.52 Master bed switch wall.
ENGIN1 COMPLETE 04/04/2023 04/05/2023
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
SW1 COMPLETE 04/04/2023 04/12/2023
Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM
ENGIN1 HOLD 03/20/2023 03/20/2023
Note: Held By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM Survey elevations differ form COPC GPS and ITT as-builts by .7'+/-
SWALE COMPLETE 03/07/2023 05/24/2023
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
BLD COMPLETE 03/06/2023 03/11/2023
Note: Released By: JPI
CUSVC COMPLETE 03/06/2023 03/08/2023
Note: Released By: LISA ASBILL - - lasbill@palmcoastgov.com
ELEC HOLD 03/06/2023 03/07/2023
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Need correct outlet spacing NEC 2017 210.52 (Master Bed)
ENGIN1 COMPLETE 03/06/2023 03/07/2023
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
GAS CANCEL 03/06/2023 03/07/2023
Note: not needed
LOCATE COMPLETE 03/06/2023 03/13/2023
Note: Released By: CANDACE STONE - - CSTONE@PALMCOASTGOV.COM
MECH COMPLETE 03/06/2023 03/07/2023
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
SW1 COMPLETE 03/06/2023 03/13/2023
Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM
ZON HOLD 03/06/2023 03/07/2023
Note: Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM Need one additional tree for this lot size
BADMIN COMPLETE 03/06/2023 03/12/2023
Note: Released By: BARBIE BEMBRY - (386)986-3780 - BUILDINGDIVISION@PALMCOASTGOV.COM

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
PLAN REVIEW - REVISION ¤32.50 01/05/2024
PLAN REVIEW - REVISION ¤32.50 01/05/2024
REINSPECTION RESIDENTIAL ¤40.00 01/05/2024
REINSPECTION RESIDENTIAL ¤40.00 01/05/2024
REINSPECTION RESIDENTIAL ¤40.00 01/05/2024
REINSPECTION RESIDENTIAL ¤40.00 01/05/2024
REINSPECTION RESIDENTIAL ¤40.00 01/05/2024
CONNECTION FEES ¤1,166.26 04/27/2023
FIRE IMPACT FEE ADMIN ¤12.62 04/27/2023
FIRE IMPACT FEE ADMIN (¤12.62) 04/27/2023
FC IMPACT FEE EMS ¤62.00 04/27/2023
IMPACT FEE FIRE ¤420.52 04/27/2023
FC IMPACT FEE LAW ENFORCEMENT ¤218.00 04/27/2023
FC IMPACT FEE LIBRARY ¤268.00 04/27/2023
IMPACT FEE PARKS ¤1,769.15 04/27/2023
IMPACT FEE SCHOOL ¤5,450.00 04/27/2023
IMPACT FEE TRANSPORTATION ¤1,812.00 04/27/2023
WATER -IRRIGATION INSPECTION ¤25.00 04/27/2023
PARKS IMPACT FEE ADMIN ¤53.07 04/27/2023
PARKS IMPACT FEE ADMIN (¤53.07) 04/27/2023
SURCHARGE FS 533.721 ¤3.43 04/27/2023
SURCHARGE - FS 468.631 ¤5.15 04/27/2023
SW ENG - FOUNDATION SURVEY ¤20.00 04/27/2023
SW ENG INSPECTION 80 ¤80.00 04/27/2023
SW ENG PRE APRON ¤30.00 04/27/2023
SW ENG - REVIEW 20 ¤20.00 04/27/2023
SW ENG RES REVIEW 200 ¤200.00 04/27/2023
TRANS IMPACT FEE ADMIN ¤54.36 04/27/2023
TRANS IMPACT FEE ADMIN (¤54.36) 04/27/2023
SEWER INSPECTION ¤25.00 04/27/2023
SEWER CAPITAL FACILITY ¤5,344.82 04/27/2023
WATER CAPITAL FACILITY FEE ¤3,923.88 04/27/2023
SITE PLAN 30 ¤30.00 04/27/2023
WATER- TURN ON ¤25.00 04/27/2023
ADJUSTMENT 50% (¤533.91) 04/27/2023
ADMINISTRATIVE RESIDENTIAL ¤30.00 04/27/2023
INSPECTION - RESIDENTIAL ¤808.50 04/27/2023
PLAN REVIEW - RESIDENTIAL ¤229.32 04/27/2023
Fees Total Due: ¤0.00 Total Paid: ¤21,697.12