I want to search for...
Permit #2023030749
Permit Details
Status: COED
| Parcel Id: 07-11-31-7025-00290-0120 |
| CONDITIONED SPACE: 1555 sqft |
| GARAGE: 434 sqft |
| OPENED PORCH (WITH ROOF) : 100 sqft |
| OPENED PORCH (WITH ROOF) : 112 sqft |
| Total Square Footage: 2201 sqft |
| Block: 00290 |
| Subdivision: 2189 - SECTION 25-PINE GROVE |
| Job Phone: 832-726-2202 |
| Location Address: 146 PEPPERDINE DR |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 04/21/2023 |
| NOC: RECORDED |
| Applicant name: JONATHON AMBAR |
| Owner: ZZMZ CASPIAN LLC |
|
Address 12472 LAKE UNDERHILL ROAD # 498 ORLANDO, FL 32828 |
| Lot: 0120 |
| Contracted Stated Job Value: ¤131,500.00 |
| Job Description: SINGLE FAMILY RESIDENCE |
| Type: CN |
Contractor
CASPIAN HOMES, LLC
| Status | Location Address | Mailing Address | State License Number | Phone |
| ACTIVE |
1802 N ALAFAYA TRAIL ORLANDO, FL 32826 |
SUITE 162 ORLANDO, FL 32826 |
CBC1264918 (Exp: 08/31/2026) | 832-726-2202 |
Sub Contractors
DAVID SCOTT MORRIS
| Status | Location Address | State License Number | Phone |
| INACTIVE |
63 LEIDEL DR PALM COAST, FL 32137 |
ER13015750 (Exp: 08/31/2026) | 386-569-7262 |
JONATHAN M PEARSON
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
209 N FORSYTH ST BUNNELL, FL 32110 |
CFC1425941 (Exp: 08/31/2026) | 386-597-0944 | 386-437-4996 |
ROBERT MICHAEL RENNER
| Status | Location Address | State License Number | Phone |
| ACTIVE |
531 CODISCO WAY SANFORD, FL 32771 |
CAC051477 (Exp: 08/31/2026) | 407-333-2665 |
TERRY BRICE DICKERSON
| Status | Location Address | State License Number | Phone |
| ACTIVE |
4300 ST JOHN'S PARKWAY ALPHARETTA, GA 30009 |
CCC1326209 (Exp: 08/31/2026) | 407-548-6733 |
Inspection History
| Type | Request Date | Result | Inspector |
| U -UTILITY RESIDENTIAL FINAL | 01/24/2024 | FINAL APPROVED | LFITZGERALD |
| Note: Inspector Notes from Inspection 9035 no irrigation-no cross connection | |||
| BLD - BUILDING FINAL | 01/17/2024 | FINAL APPROVED | KSANDOE |
| ROW - FINAL APRON (AFTER POUR) | 01/08/2024 | APPROVED | RGROSS |
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 01/08/2024 | APPROVED | RGROSS |
| Note: 1/4/2024 - PREVIOUS INSPECTION NOTES THE FINAL SURVEY STILL SHOWS THE CULVERT PIPE OUT OF TOLERANCE WITH THE SWALE PLAN DIAGRAM AND PITCHED IN THE WRONG DIRECTION AS WELL. LOOKS LIKE THE SAME SURVEY PLEASE HAVE THE SURVEYOR SHOT THE CULVERT AGAIN AND IF THE SAME PLEASE CONTACT US. ----------------------------------------------------------------------------------------------- Culvert Out of Tolerence 12/28/2023 - PREVIOUS INSPECTION NOTES 12/28/23 THE FINAL SURVEY SHOWS THE CULVERT PIPEOUT OF TOLERANCE WITH THE SWALE PLAN DIAGRAM AND PITCHED IN THE WRONG DIRECTION AS WELL. Culvert Out of Tolerence Swale Plan #1 Swale Plan #1. The driveway culvert inverts are to be installed within 0.1' (+/-) of the elevations indicated on the swale plan (unless otherwise approved by the City StormwaterEngineer). The finished swale elevation is with sod in place Culvert cannot flow more than a tenth in the right direction Sec.300.01c3 Sec 300.01c3 The driveway culvert(s) must be set within the range established by the Swale Plan. The culvert cannot be sloped against the drainage flow nor shall it be sloped more than 0.10 feet in the direction of the drainage flow. Inspector Notes from Inspection 9270 AT THE TIME OF THE INSPECTION, THE CULVERT PIPE IS GOOD AND READY TO POUR; THE BUILDER SHOULD DOUBLE-CHECK THE CULVERT ELEVATIONS BEFORE POURING. MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300E RESIDENTIAL CULVERT DETAIL | |||
| ROW FIELD SURVEY /GRADING CERTIFICATION | 01/08/2024 | APPROVED | RGROSS |
| ROW - STORMWATER FINAL | 01/08/2024 | APPROVED | RGROSS |
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 01/04/2024 | Disapproved -FEE REQUIRED | PFLANAGAN |
| Note: THE FINAL SURVEY STILL SHOWS THE CULVERT PIPE OUT OF TOLERANCE WITH THE SWALE PLAN DIAGRAM AND PITCHED IN THE WRONG DIRECTION AS WELL. LOOKS LIKE THE SAME SURVEY PLEASE HAVE THE SURVEYOR SHOT THE CULVERT AGAIN AND IF THE SAME PLEASE CONTACT US. ----------------------------------------------------------------------------------------------- Culvert Out of Tolerence 12/28/2023 - PREVIOUS INSPECTION NOTES 12/28/23 THE FINAL SURVEY SHOWS THE CULVERT PIPEOUT OF TOLERANCE WITH THE SWALE PLAN DIAGRAM AND PITCHED IN THE WRONG DIRECTION AS WELL. Culvert Out of Tolerence Swale Plan #1 Swale Plan #1. The driveway culvert inverts are to be installed within 0.1' (+/-) of the elevations indicated on the swale plan (unless otherwise approved by the City StormwaterEngineer). The finished swale elevation is with sod in place Culvert cannot flow more than a tenth in the right direction Sec.300.01c3 Sec 300.01c3 The driveway culvert(s) must be set within the range established by the Swale Plan. The culvert cannot be sloped against the drainage flow nor shall it be sloped more than 0.10 feet in the direction of the drainage flow. Inspector Notes from Inspection 9270 AT THE TIME OF THE INSPECTION, THE CULVERT PIPE IS GOOD AND READY TO POUR; THE BUILDER SHOULD DOUBLE-CHECK THE CULVERT ELEVATIONS BEFORE POURING. MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300E RESIDENTIAL CULVERT DETAIL | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 12/28/2023 | Disapproved - NO FEE | FSLADISH |
| Note: 12/28/23 THE FINAL SURVEY SHOWS THE CULVERT PIPEOUT OF TOLERANCE WITH THE SWALE PLAN DIAGRAM AND PITCHED IN THE WRONG DIRECTION AS WELL. Culvert Out of Tolerence Swale Plan #1 Swale Plan #1. The driveway culvert inverts are to be installed within 0.1' (+/-) of the elevations indicated on the swale plan (unless otherwise approved by the City StormwaterEngineer). The finished swale elevation is with sod in place Culvert cannot flow more than a tenth in the right direction Sec.300.01c3 Sec 300.01c3 The driveway culvert(s) must be set within the range established by the Swale Plan. The culvert cannot be sloped against the drainage flow nor shall it be sloped more than 0.10 feet in the direction of the drainage flow. Inspector Notes from Inspection 9270 AT THE TIME OF THE INSPECTION, THE CULVERT PIPE IS GOOD AND READY TO POUR; THE BUILDER SHOULD DOUBLE-CHECK THE CULVERT ELEVATIONS BEFORE POURING. MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300E RESIDENTIAL CULVERT DETAIL | |||
| ELECTRIC - EARLY POWER | 11/22/2023 | APPROVED - AS NOTED | KSANDOE |
| Note: Emailed FPL @ 0925. Release Power 11/21/2023 - PREVIOUS INSPECTION NOTES 408.4(A) Circuit Directory or Circuit Identification. Every circuit and circuit modification shall be legibly identified as to its clear, evident, and specific purpose or use 11/16/2023 - PREVIOUS INSPECTION NOTES Missing breakers in panel. No labels in panel 11/13/2023 - PREVIOUS INSPECTION NOTES 11/13/23: Inspection stopped! Service feeds cannot be landed at the meter panel for Early Power. Inspector Notes from Inspection 2200 9/8/23- Authorize release of email to FPL @ 2:01pm | |||
| ELECTRIC - EARLY POWER | 11/21/2023 | Disapproved -FEE REQUIRED | KSANDOE |
| Note: 408.4(A) Circuit Directory or Circuit Identification. Every circuit and circuit modification shall be legibly identified as to its clear, evident, and specific purpose or use 11/16/2023 - PREVIOUS INSPECTION NOTES Missing breakers in panel. No labels in panel 11/13/2023 - PREVIOUS INSPECTION NOTES 11/13/23: Inspection stopped! Service feeds cannot be landed at the meter panel for Early Power. Inspector Notes from Inspection 2200 9/8/23- Authorize release of email to FPL @ 2:01pm | |||
| ELECTRIC - EARLY POWER | 11/16/2023 | Disapproved - NO FEE | KSANDOE |
| Note: Missing breakers in panel. No labels in panel 11/13/2023 - PREVIOUS INSPECTION NOTES 11/13/23: Inspection stopped! Service feeds cannot be landed at the meter panel for Early Power. Inspector Notes from Inspection 2200 9/8/23- Authorize release of email to FPL @ 2:01pm | |||
| ELECTRIC - EARLY POWER | 11/13/2023 | Disapproved -FEE REQUIRED | RSIMS |
| Note: 11/13/23: Inspection stopped! Service feeds (for underground power) cannot be landed at the meter panel for Early Power. Inspector Notes from Inspection 2200 9/8/23- Authorize release of email to FPL @ 2:01pm | |||
| ROW- PRE-APRON (PRE-POUR) | 10/31/2023 | APPROVED - AS NOTED | GBERTOLA |
| Note: AT THE TIME OF THE INSPECTION, THE CULVERT PIPE IS GOOD AND READY TO POUR; THE BUILDER SHOULD DOUBLE-CHECK THE CULVERT ELEVATIONS BEFORE POURING. MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300E RESIDENTIAL CULVERT DETAIL | |||
| U-CROSS CONNECTION | 10/02/2023 | APPROVED - AS NOTED | LFITZGERALD |
| Note: no irrigation-no cross connection | |||
| U - SEWER TIE IN | 10/02/2023 | APPROVED - AS NOTED | MGIBSON |
| Note: Inspector Notes from Inspection 2060 NEED PORTABLE RESTROOM BEFORE SCHEDULING MONOLITHIC SLAB INSPECTION THIS WAS A VIRTUAL INSPECTION | |||
| GRAVITY SEWER TEST | 10/02/2023 | APPROVED - AS NOTED | MGIBSON |
| Note: Inspector Notes from Inspection 2060 NEED PORTABLE RESTROOM BEFORE SCHEDULING MONOLITHIC SLAB INSPECTION THIS WAS A VIRTUAL INSPECTION | |||
| ELECTRIC-TUG | 09/08/2023 | APPROVED - AS NOTED | JSTEWART |
| Note: 9/8/23- Authorize release of email to FPL @ 2:01pm | |||
| LATH/BRICK/ WATER BARRIER | 07/28/2023 | APPROVED | KSANDOE |
| INSULATION | 07/25/2023 | APPROVED | FWILLIS |
| Note: Inspector Notes from Inspection 2420 Dryer vent is protruding from top plate outside wall | |||
| ALL ROUGH | 07/20/2023 | APPROVED - AS NOTED | KSANDOE |
| Note: Dryer vent is protruding from top plate outside wall | |||
| WALL SHEATHING | 07/07/2023 | APPROVED | KSANDOE |
| Note: 7/5/2023 - PREVIOUS INSPECTION NOTES Not ready for inspection. Crews still working | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 07/07/2023 | APPROVED | KSANDOE |
| Note: 7/5/2023 - PREVIOUS INSPECTION NOTES Not ready for inspection. Crews still working | |||
| ROOF VALLEY & METAL | 07/07/2023 | APPROVED | KSANDOE |
| Note: 7/5/2023 - PREVIOUS INSPECTION NOTES Not ready for inspection. Crews still working | |||
| ROOF VALLEY & METAL | 07/05/2023 | Disapproved - NO FEE | KSANDOE |
| Note: Not ready for inspection. Crews still working | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 07/05/2023 | CANCELLED BY APPLICANT | KSANDOE |
| Note: Not ready for inspection. Crews still working | |||
| WALL SHEATHING | 07/05/2023 | Disapproved - NO FEE | KSANDOE |
| Note: Not ready for inspection. Crews still working | |||
| FOUND SURVEY APPROVED (OFFICE) | 06/20/2023 | APPROVED | TBAKER |
| TIE BEAM / LINTEL | 06/12/2023 | APPROVED | KSANDOE |
| MONOLITHIC SLAB | 06/01/2023 | APPROVED | TSTAUFFACHER |
| PLUMBING 1ST ROUGH UNDERGROUND | 05/25/2023 | APPROVED - AS NOTED | MGIBSON |
| Note: NEED PORTABLE RESTROOM BEFORE SCHEDULING MONOLITHIC SLAB INSPECTION | |||
| WATER METER INSTALLATION REQUEST | 05/15/2023 | APPROVED | CSTONE |
Review History
| Department | Status | Date In | Date Out |
| ENGIN1 | COMPLETE | 06/20/2023 | 06/20/2023 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 06/20/2023 | 06/20/2023 |
| Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 03/31/2023 | 03/31/2023 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 03/24/2023 | 03/24/2023 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| MECH | HOLD | 03/24/2023 | 03/24/2023 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Energy Calcs need to be signed by the owner/ owner agent below the preparer per R103.1.1.2 FBC Energy Conservation 2020 7Th edition | |||
| SW1 | COMPLETE | 03/24/2023 | 03/30/2023 |
| Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 03/24/2023 | 03/24/2023 |
| Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM | |||
| SWALE | COMPLETE | 03/24/2023 | 05/31/2023 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 03/14/2023 | 03/19/2023 |
| Note: Released By: JPI | |||
| CUSVC | COMPLETE | 03/14/2023 | 03/16/2023 |
| Note: Released By: LISA ASBILL - - lasbill@palmcoastgov.com | |||
| ELEC | COMPLETE | 03/14/2023 | 03/16/2023 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ENGIN1 | HOLD | 03/14/2023 | 03/15/2023 |
| Note: Held By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM Please carry all spot grades to the nearest hundredth of a foot. | |||
| GAS | CANCEL | 03/14/2023 | 03/15/2023 |
| Note: not needed | |||
| LOCATE | COMPLETE | 03/14/2023 | 03/21/2023 |
| Note: Released By: CANDACE STONE - - CSTONE@PALMCOASTGOV.COM | |||
| MECH | HOLD | 03/14/2023 | 03/15/2023 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Design location on heatload needs to be Daytona Beach | |||
| SW1 | COMPLETE | 03/14/2023 | 03/20/2023 |
| Note: Released By: EDWARD MADISON - - EMADISON@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 03/14/2023 | 03/15/2023 |
| Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM | |||
| BADMIN | COMPLETE | 03/14/2023 | 03/20/2023 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION RESIDENTIAL | ¤40.00 | 02/07/2024 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 02/07/2024 |
| CONNECTION FEES | ¤1,166.26 | 04/21/2023 |
| FIRE IMPACT FEE ADMIN | ¤12.62 | 04/21/2023 |
| FIRE IMPACT FEE ADMIN | (¤12.62) | 04/21/2023 |
| FC IMPACT FEE EMS | ¤62.00 | 04/21/2023 |
| FC IMPACT FEE EMS | ¤62.00 | 04/21/2023 |
| IMPACT FEE FIRE | ¤420.52 | 04/21/2023 |
| FC IMPACT FEE LAW ENFORCEMENT | ¤218.00 | 04/21/2023 |
| FC IMPACT FEE LAW ENFORCEMENT | ¤218.00 | 04/21/2023 |
| FC IMPACT FEE LIBRARY | ¤268.00 | 04/21/2023 |
| FC IMPACT FEE LIBRARY | ¤268.00 | 04/21/2023 |
| IMPACT FEE PARKS | ¤1,769.15 | 04/21/2023 |
| IMPACT FEE SCHOOL | ¤5,450.00 | 04/21/2023 |
| IMPACT FEE TRANSPORTATION | ¤1,812.00 | 04/21/2023 |
| WATER -IRRIGATION INSPECTION | ¤25.00 | 04/21/2023 |
| PARKS IMPACT FEE ADMIN | ¤53.07 | 04/21/2023 |
| PARKS IMPACT FEE ADMIN | (¤53.07) | 04/21/2023 |
| SURCHARGE FS 533.721 | ¤2.47 | 04/21/2023 |
| SURCHARGE - FS 468.631 | ¤3.71 | 04/21/2023 |
| SW ENG - FOUNDATION SURVEY | ¤20.00 | 04/21/2023 |
| SW ENG INSPECTION 80 | ¤80.00 | 04/21/2023 |
| SW ENG PRE APRON | ¤30.00 | 04/21/2023 |
| SW ENG - REVIEW 20 | ¤20.00 | 04/21/2023 |
| SW ENG RES REVIEW 200 | ¤200.00 | 04/21/2023 |
| TRANS IMPACT FEE ADMIN | ¤54.36 | 04/21/2023 |
| TRANS IMPACT FEE ADMIN | (¤54.36) | 04/21/2023 |
| SEWER CREDIT | (¤860.60) | 04/21/2023 |
| SEWER INSPECTION | ¤25.00 | 04/21/2023 |
| SEWER CAPITAL FACILITY | ¤5,344.82 | 04/21/2023 |
| WATER CAPITAL FACILITY FEE | ¤3,923.88 | 04/21/2023 |
| SITE PLAN 30 | ¤30.00 | 04/21/2023 |
| WATER- TURN ON | ¤25.00 | 04/21/2023 |
| ADJUSTMENT 50% | (¤366.24) | 04/21/2023 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 04/21/2023 |
| INSPECTION - RESIDENTIAL | ¤547.25 | 04/21/2023 |
| PLAN REVIEW - RESIDENTIAL | ¤155.22 | 04/21/2023 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤21,029.44 |