I want to search for...

Permit #2023030749

Permit Details

Status: COED

Parcel Id: 07-11-31-7025-00290-0120
CONDITIONED SPACE: 1555 sqft
GARAGE: 434 sqft
OPENED PORCH (WITH ROOF) : 100 sqft
OPENED PORCH (WITH ROOF) : 112 sqft
Total Square Footage: 2201 sqft
Block: 00290
Subdivision: 2189 - SECTION 25-PINE GROVE
Job Phone: 832-726-2202
Location Address: 146 PEPPERDINE DR
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 04/21/2023
NOC: RECORDED
Applicant name: JONATHON AMBAR
Owner: ZZMZ CASPIAN LLC

Address

12472 LAKE UNDERHILL ROAD # 498

ORLANDO, FL 32828

Lot: 0120
Contracted Stated Job Value: ¤131,500.00
Job Description: SINGLE FAMILY RESIDENCE
Type: CN

Contractor

CASPIAN HOMES, LLC
Status Location Address Mailing Address State License Number Phone
ACTIVE

1802 N ALAFAYA TRAIL

ORLANDO, FL 32826

SUITE 162

ORLANDO, FL 32826

CBC1264918 (Exp: 08/31/2026) 832-726-2202

Sub Contractors

DAVID SCOTT MORRIS
Status Location Address State License Number Phone
INACTIVE

63 LEIDEL DR

PALM COAST, FL 32137

ER13015750 (Exp: 08/31/2026) 386-569-7262
JONATHAN M PEARSON
Status Location Address State License Number Phone Fax
ACTIVE

209 N FORSYTH ST

BUNNELL, FL 32110

CFC1425941 (Exp: 08/31/2026) 386-597-0944 386-437-4996
ROBERT MICHAEL RENNER
Status Location Address State License Number Phone
ACTIVE

531 CODISCO WAY

SANFORD, FL 32771

CAC051477 (Exp: 08/31/2026) 407-333-2665
TERRY BRICE DICKERSON
Status Location Address State License Number Phone
ACTIVE

4300 ST JOHN'S PARKWAY

ALPHARETTA, GA 30009

CCC1326209 (Exp: 08/31/2026) 407-548-6733

Inspection History

Type Request Date Result Inspector
U -UTILITY RESIDENTIAL FINAL 01/24/2024 FINAL APPROVED LFITZGERALD
Note: Inspector Notes from Inspection 9035 no irrigation-no cross connection
BLD - BUILDING FINAL 01/17/2024 FINAL APPROVED KSANDOE
ROW - FINAL APRON (AFTER POUR) 01/08/2024 APPROVED RGROSS
ROW- FINAL SURVEY/GRADING CERTIFICATION 01/08/2024 APPROVED RGROSS
Note: 1/4/2024 - PREVIOUS INSPECTION NOTES THE FINAL SURVEY STILL SHOWS THE CULVERT PIPE OUT OF TOLERANCE WITH THE SWALE PLAN DIAGRAM AND PITCHED IN THE WRONG DIRECTION AS WELL. LOOKS LIKE THE SAME SURVEY PLEASE HAVE THE SURVEYOR SHOT THE CULVERT AGAIN AND IF THE SAME PLEASE CONTACT US. ----------------------------------------------------------------------------------------------- Culvert Out of Tolerence 12/28/2023 - PREVIOUS INSPECTION NOTES 12/28/23 THE FINAL SURVEY SHOWS THE CULVERT PIPEOUT OF TOLERANCE WITH THE SWALE PLAN DIAGRAM AND PITCHED IN THE WRONG DIRECTION AS WELL. Culvert Out of Tolerence Swale Plan #1 Swale Plan #1. The driveway culvert inverts are to be installed within 0.1' (+/-) of the elevations indicated on the swale plan (unless otherwise approved by the City StormwaterEngineer). The finished swale elevation is with sod in place Culvert cannot flow more than a tenth in the right direction Sec.300.01c3 Sec 300.01c3 The driveway culvert(s) must be set within the range established by the Swale Plan. The culvert cannot be sloped against the drainage flow nor shall it be sloped more than 0.10 feet in the direction of the drainage flow. Inspector Notes from Inspection 9270 AT THE TIME OF THE INSPECTION, THE CULVERT PIPE IS GOOD AND READY TO POUR; THE BUILDER SHOULD DOUBLE-CHECK THE CULVERT ELEVATIONS BEFORE POURING. MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300E RESIDENTIAL CULVERT DETAIL
ROW FIELD SURVEY /GRADING CERTIFICATION 01/08/2024 APPROVED RGROSS
ROW - STORMWATER FINAL 01/08/2024 APPROVED RGROSS
ROW- FINAL SURVEY/GRADING CERTIFICATION 01/04/2024 Disapproved -FEE REQUIRED PFLANAGAN
Note: THE FINAL SURVEY STILL SHOWS THE CULVERT PIPE OUT OF TOLERANCE WITH THE SWALE PLAN DIAGRAM AND PITCHED IN THE WRONG DIRECTION AS WELL. LOOKS LIKE THE SAME SURVEY PLEASE HAVE THE SURVEYOR SHOT THE CULVERT AGAIN AND IF THE SAME PLEASE CONTACT US. ----------------------------------------------------------------------------------------------- Culvert Out of Tolerence 12/28/2023 - PREVIOUS INSPECTION NOTES 12/28/23 THE FINAL SURVEY SHOWS THE CULVERT PIPEOUT OF TOLERANCE WITH THE SWALE PLAN DIAGRAM AND PITCHED IN THE WRONG DIRECTION AS WELL. Culvert Out of Tolerence Swale Plan #1 Swale Plan #1. The driveway culvert inverts are to be installed within 0.1' (+/-) of the elevations indicated on the swale plan (unless otherwise approved by the City StormwaterEngineer). The finished swale elevation is with sod in place Culvert cannot flow more than a tenth in the right direction Sec.300.01c3 Sec 300.01c3 The driveway culvert(s) must be set within the range established by the Swale Plan. The culvert cannot be sloped against the drainage flow nor shall it be sloped more than 0.10 feet in the direction of the drainage flow. Inspector Notes from Inspection 9270 AT THE TIME OF THE INSPECTION, THE CULVERT PIPE IS GOOD AND READY TO POUR; THE BUILDER SHOULD DOUBLE-CHECK THE CULVERT ELEVATIONS BEFORE POURING. MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300E RESIDENTIAL CULVERT DETAIL
ROW- FINAL SURVEY/GRADING CERTIFICATION 12/28/2023 Disapproved - NO FEE FSLADISH
Note: 12/28/23 THE FINAL SURVEY SHOWS THE CULVERT PIPEOUT OF TOLERANCE WITH THE SWALE PLAN DIAGRAM AND PITCHED IN THE WRONG DIRECTION AS WELL. Culvert Out of Tolerence Swale Plan #1 Swale Plan #1. The driveway culvert inverts are to be installed within 0.1' (+/-) of the elevations indicated on the swale plan (unless otherwise approved by the City StormwaterEngineer). The finished swale elevation is with sod in place Culvert cannot flow more than a tenth in the right direction Sec.300.01c3 Sec 300.01c3 The driveway culvert(s) must be set within the range established by the Swale Plan. The culvert cannot be sloped against the drainage flow nor shall it be sloped more than 0.10 feet in the direction of the drainage flow. Inspector Notes from Inspection 9270 AT THE TIME OF THE INSPECTION, THE CULVERT PIPE IS GOOD AND READY TO POUR; THE BUILDER SHOULD DOUBLE-CHECK THE CULVERT ELEVATIONS BEFORE POURING. MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300E RESIDENTIAL CULVERT DETAIL
ELECTRIC - EARLY POWER 11/22/2023 APPROVED - AS NOTED KSANDOE
Note: Emailed FPL @ 0925. Release Power 11/21/2023 - PREVIOUS INSPECTION NOTES 408.4(A) Circuit Directory or Circuit Identification. Every circuit and circuit modification shall be legibly identified as to its clear, evident, and specific purpose or use 11/16/2023 - PREVIOUS INSPECTION NOTES Missing breakers in panel. No labels in panel 11/13/2023 - PREVIOUS INSPECTION NOTES 11/13/23: Inspection stopped! Service feeds cannot be landed at the meter panel for Early Power. Inspector Notes from Inspection 2200 9/8/23- Authorize release of email to FPL @ 2:01pm
ELECTRIC - EARLY POWER 11/21/2023 Disapproved -FEE REQUIRED KSANDOE
Note: 408.4(A) Circuit Directory or Circuit Identification. Every circuit and circuit modification shall be legibly identified as to its clear, evident, and specific purpose or use 11/16/2023 - PREVIOUS INSPECTION NOTES Missing breakers in panel. No labels in panel 11/13/2023 - PREVIOUS INSPECTION NOTES 11/13/23: Inspection stopped! Service feeds cannot be landed at the meter panel for Early Power. Inspector Notes from Inspection 2200 9/8/23- Authorize release of email to FPL @ 2:01pm
ELECTRIC - EARLY POWER 11/16/2023 Disapproved - NO FEE KSANDOE
Note: Missing breakers in panel. No labels in panel 11/13/2023 - PREVIOUS INSPECTION NOTES 11/13/23: Inspection stopped! Service feeds cannot be landed at the meter panel for Early Power. Inspector Notes from Inspection 2200 9/8/23- Authorize release of email to FPL @ 2:01pm
ELECTRIC - EARLY POWER 11/13/2023 Disapproved -FEE REQUIRED RSIMS
Note: 11/13/23: Inspection stopped! Service feeds (for underground power) cannot be landed at the meter panel for Early Power. Inspector Notes from Inspection 2200 9/8/23- Authorize release of email to FPL @ 2:01pm
ROW- PRE-APRON (PRE-POUR) 10/31/2023 APPROVED - AS NOTED GBERTOLA
Note: AT THE TIME OF THE INSPECTION, THE CULVERT PIPE IS GOOD AND READY TO POUR; THE BUILDER SHOULD DOUBLE-CHECK THE CULVERT ELEVATIONS BEFORE POURING. MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300E RESIDENTIAL CULVERT DETAIL
U-CROSS CONNECTION 10/02/2023 APPROVED - AS NOTED LFITZGERALD
Note: no irrigation-no cross connection
U - SEWER TIE IN 10/02/2023 APPROVED - AS NOTED MGIBSON
Note: Inspector Notes from Inspection 2060 NEED PORTABLE RESTROOM BEFORE SCHEDULING MONOLITHIC SLAB INSPECTION THIS WAS A VIRTUAL INSPECTION
GRAVITY SEWER TEST 10/02/2023 APPROVED - AS NOTED MGIBSON
Note: Inspector Notes from Inspection 2060 NEED PORTABLE RESTROOM BEFORE SCHEDULING MONOLITHIC SLAB INSPECTION THIS WAS A VIRTUAL INSPECTION
ELECTRIC-TUG 09/08/2023 APPROVED - AS NOTED JSTEWART
Note: 9/8/23- Authorize release of email to FPL @ 2:01pm
LATH/BRICK/ WATER BARRIER 07/28/2023 APPROVED KSANDOE
INSULATION 07/25/2023 APPROVED FWILLIS
Note: Inspector Notes from Inspection 2420 Dryer vent is protruding from top plate outside wall
ALL ROUGH 07/20/2023 APPROVED - AS NOTED KSANDOE
Note: Dryer vent is protruding from top plate outside wall
WALL SHEATHING 07/07/2023 APPROVED KSANDOE
Note: 7/5/2023 - PREVIOUS INSPECTION NOTES Not ready for inspection. Crews still working
ROOF SHEATHING / BRACES/TIES/DOWN CELL 07/07/2023 APPROVED KSANDOE
Note: 7/5/2023 - PREVIOUS INSPECTION NOTES Not ready for inspection. Crews still working
ROOF VALLEY & METAL 07/07/2023 APPROVED KSANDOE
Note: 7/5/2023 - PREVIOUS INSPECTION NOTES Not ready for inspection. Crews still working
ROOF VALLEY & METAL 07/05/2023 Disapproved - NO FEE KSANDOE
Note: Not ready for inspection. Crews still working
ROOF SHEATHING / BRACES/TIES/DOWN CELL 07/05/2023 CANCELLED BY APPLICANT KSANDOE
Note: Not ready for inspection. Crews still working
WALL SHEATHING 07/05/2023 Disapproved - NO FEE KSANDOE
Note: Not ready for inspection. Crews still working
FOUND SURVEY APPROVED (OFFICE) 06/20/2023 APPROVED TBAKER
TIE BEAM / LINTEL 06/12/2023 APPROVED KSANDOE
MONOLITHIC SLAB 06/01/2023 APPROVED TSTAUFFACHER
PLUMBING 1ST ROUGH UNDERGROUND 05/25/2023 APPROVED - AS NOTED MGIBSON
Note: NEED PORTABLE RESTROOM BEFORE SCHEDULING MONOLITHIC SLAB INSPECTION
WATER METER INSTALLATION REQUEST 05/15/2023 APPROVED CSTONE

Review History

Department Status Date In Date Out
ENGIN1 COMPLETE 06/20/2023 06/20/2023
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON COMPLETE 06/20/2023 06/20/2023
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
MECH COMPLETE 03/31/2023 03/31/2023
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
ENGIN1 COMPLETE 03/24/2023 03/24/2023
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
MECH HOLD 03/24/2023 03/24/2023
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Energy Calcs need to be signed by the owner/ owner agent below the preparer per R103.1.1.2 FBC Energy Conservation 2020 7Th edition
SW1 COMPLETE 03/24/2023 03/30/2023
Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM
ZON COMPLETE 03/24/2023 03/24/2023
Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM
SWALE COMPLETE 03/24/2023 05/31/2023
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
BLD COMPLETE 03/14/2023 03/19/2023
Note: Released By: JPI
CUSVC COMPLETE 03/14/2023 03/16/2023
Note: Released By: LISA ASBILL - - lasbill@palmcoastgov.com
ELEC COMPLETE 03/14/2023 03/16/2023
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ENGIN1 HOLD 03/14/2023 03/15/2023
Note: Held By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM Please carry all spot grades to the nearest hundredth of a foot.
GAS CANCEL 03/14/2023 03/15/2023
Note: not needed
LOCATE COMPLETE 03/14/2023 03/21/2023
Note: Released By: CANDACE STONE - - CSTONE@PALMCOASTGOV.COM
MECH HOLD 03/14/2023 03/15/2023
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Design location on heatload needs to be Daytona Beach
SW1 COMPLETE 03/14/2023 03/20/2023
Note: Released By: EDWARD MADISON - - EMADISON@PALMCOASTGOV.COM
ZON COMPLETE 03/14/2023 03/15/2023
Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM
BADMIN COMPLETE 03/14/2023 03/20/2023
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION RESIDENTIAL ¤40.00 02/07/2024
REINSPECTION RESIDENTIAL ¤40.00 02/07/2024
CONNECTION FEES ¤1,166.26 04/21/2023
FIRE IMPACT FEE ADMIN ¤12.62 04/21/2023
FIRE IMPACT FEE ADMIN (¤12.62) 04/21/2023
FC IMPACT FEE EMS ¤62.00 04/21/2023
FC IMPACT FEE EMS ¤62.00 04/21/2023
IMPACT FEE FIRE ¤420.52 04/21/2023
FC IMPACT FEE LAW ENFORCEMENT ¤218.00 04/21/2023
FC IMPACT FEE LAW ENFORCEMENT ¤218.00 04/21/2023
FC IMPACT FEE LIBRARY ¤268.00 04/21/2023
FC IMPACT FEE LIBRARY ¤268.00 04/21/2023
IMPACT FEE PARKS ¤1,769.15 04/21/2023
IMPACT FEE SCHOOL ¤5,450.00 04/21/2023
IMPACT FEE TRANSPORTATION ¤1,812.00 04/21/2023
WATER -IRRIGATION INSPECTION ¤25.00 04/21/2023
PARKS IMPACT FEE ADMIN ¤53.07 04/21/2023
PARKS IMPACT FEE ADMIN (¤53.07) 04/21/2023
SURCHARGE FS 533.721 ¤2.47 04/21/2023
SURCHARGE - FS 468.631 ¤3.71 04/21/2023
SW ENG - FOUNDATION SURVEY ¤20.00 04/21/2023
SW ENG INSPECTION 80 ¤80.00 04/21/2023
SW ENG PRE APRON ¤30.00 04/21/2023
SW ENG - REVIEW 20 ¤20.00 04/21/2023
SW ENG RES REVIEW 200 ¤200.00 04/21/2023
TRANS IMPACT FEE ADMIN ¤54.36 04/21/2023
TRANS IMPACT FEE ADMIN (¤54.36) 04/21/2023
SEWER CREDIT (¤860.60) 04/21/2023
SEWER INSPECTION ¤25.00 04/21/2023
SEWER CAPITAL FACILITY ¤5,344.82 04/21/2023
WATER CAPITAL FACILITY FEE ¤3,923.88 04/21/2023
SITE PLAN 30 ¤30.00 04/21/2023
WATER- TURN ON ¤25.00 04/21/2023
ADJUSTMENT 50% (¤366.24) 04/21/2023
ADMINISTRATIVE RESIDENTIAL ¤30.00 04/21/2023
INSPECTION - RESIDENTIAL ¤547.25 04/21/2023
PLAN REVIEW - RESIDENTIAL ¤155.22 04/21/2023
Fees Total Due: ¤0.00 Total Paid: ¤21,029.44