Permit #2023030964

Permit Details

Status: COED

Parcel Id: 07-11-31-7026-00010-0140
GARAGE: 262 sqft
CONDITIONED SPACE: 1298 sqft
OPENED PORCH (WITH ROOF) : 27 sqft
OPENED PORCH (WITH ROOF) : 50 sqft
CONDITIONED SPACE: 1298 sqft
GARAGE: 262 sqft
OPENED PORCH (WITH ROOF) : 50 sqft
OPENED PORCH (WITH ROOF) : 27 sqft
Total Square Footage: 3274 sqft
Block: 00010
Subdivision: 2153 - SECTION 26-PINE GROVE
Job Phone: 863-647-5815
Location Address: 29 PINE GROVE DR
Type: DU - DUPLEX
Issue Date: 04/17/2023
NOC: RECORDED
Applicant name: MARK ALLAN HULBERT
Owner: HULBERT HOMES INC

Address

PO BOX 6254

LAKELAND, FL 33807

Lot: 0140
Contracted Stated Job Value: ¤300,000.00
Job Description: Duplex
Type: CN

Contractor

HULBERT HOMES INC
Status Location Address State License Number Phone
INACTIVE

PO BOX 6254

LAKELAND, FL 33813

CRC1331304 (Exp: 08/31/2026) 863-647-5815

Sub Contractors

MOISES MERINO DIAZ
Status Location Address State License Number Phone
ACTIVE

3104 ORANOLE ROAD

ORLANDO, FL 32810

CAC1820980 (Exp: 08/31/2026) 407-225-3149
ANTONIO VINCENZO DAHM
Status Location Address State License Number Phone
ACTIVE

10 RYBAR LANE

PALM COAST, FL 32164

CFC1429951 (Exp: 08/31/2026) 386-237-5692
DUSTIN L ESTEP
Status Location Address State License Number Phone Fax
ACTIVE

2041 N HIAWASSEE RD

APOPKA, FL 32703

CCC1330971 (Exp: 08/31/2026) 407-702-0206 352-988-6629
JOSEPH C WRIGHT
Status Location Address Mailing Address State License Number Phone Fax
ACTIVE

15 HARGROVE LANE

PALM COAST, FL 32137

UNIT 3 D

PALM COAST, FL 32137

EC13003278 (Exp: 08/31/2026) 386-447-9644 386-447-9633

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 06/03/2024 FINAL APPROVED BTAYLOR
Note: 5/29/2024 - PREVIOUS INSPECTION NOTES 5/29/24: Walked with Superintendent. Not Ready for Building Final Inspection. (a full inspection will be needed except for the items checked & approved as listed below. Approved (listed items only): * Smoke alarms / Insulation / AHU (in attic) & Condenser (installation only as energy calcs do not match & condensate lines are not 6" above grade) / B side dryer exhaust gooseneck - A side still has screen installed.
ROW - FINAL INSPECTION 06/03/2024 APPROVED - AS NOTED PFLANAGAN
Note: CORRECTION MADE TO SWALE. TALKED TO CM ABOUT THE THE CULVERTS NEED TO BE CLEANED OUT HE STATES IT WILL BE TAKEN CARE OF. ---------------------------------------------------------------------------------- 5/22/2024 - PREVIOUS INSPECTION NOTES Inspector Notes from Inspection 9465 5/22/24 READ PREVIOUS INSPECTION NOTES. AS MENTIONED ON THE FINAL SURVEY INSPECTION YOUR RIGHT SIDE FRONT SWALE ELEVATIONS (24.6) ARE HIGHER THAN THE LEFT SIDE (24.3) FLOW IS LEFT TO RIGHT, YOU WILL NEED TO BRING THE SWALE DOWN 3 TENTHS ON THE RIGHT AND RUN IT FLAT AT 24.3 TO MATCH THE GRADE AT THE ADJOINING PROPERTY LINE. I AM APPROVING THIS FIELD SURVEY AS NOTED, CORRECTIONS REQUIRED NEED TO BE MADE BEFORE ROW FINAL SUBMITTAL. AREA HIGHLIGHTED IN WHITE PAINT THAT NEEDS CORRECTION. 5/21/24 UPON WALKING PROPERTY DETERMINED DRAINAGE WILL NOW FLOW AROUND PEP TANK AND REACH THE FRONT SWALE. AS MENTIONED ON THE FINAL SURVEY INSPECTION YOUR RIGHT SIDE FRONT SWALE ELEVATIONS (24.6) ARE HIGHER THAN THE LEFT SIDE (24.3) FLOW IS LEFT TO RIGHT, YOU WILL NEED TO BRING THE SWALE DOWN 3 TENTHS ON THE RIGHT AND RUN IT FLAT AT 24.3 TO MATCH THE GRADE AT THE ADJOINING PROPERTY LINE. I AM APPROVING THIS FIELD SURVEY AS NOTED, CORRECTIONS REQUIRED NEED TO BE MADE BEFORE ROW FINAL SUBMITTAL. ______________________________________________________________________________________________________________________ Inspector Notes from Inspection 9463 5/21/24 PEP TANK DRAINAGE ELEVATION ISSUE CORRECTED. YOU ARE SHOWING THE RIGHT SIDE FRONT SWALE lOW SIDE) 3 TENTHS HIGHER THAN THE LEFT SIDE SWALE. WILL DETERMINE IF THIS IS CORRECT DURING FIELD SURVEY INSPECTION. APPROVING THIS FINAL SURVEY AS NOTED THAT FIELD CORRECTIONS MAY BE REQUIRED. 4/1/2024 - PREVIOUS INSPECTION NOTES 04/01/24 THERE WERE SOME CORRECTIONS MADE FROM PREVIOUS INSPECTION. THE AREA AROUND THE PEP TANK AND THE BACK LEFT CORNERS WILL WORK. THE AREA THAT WAS IN QUESTION ON THE BACK RIGHT WAS DUG TOO DEEP. THERRE IS NOW A LOW AREA THAT WILL HOLD WATER. IF YOU FEEL THIS IS NOT THE CASE PLEASE SUBMIT ANOTHER FINAL SURVEY WITH NEW ELEVATIONS INDICATING PROPER DRAINAGE ALONG RIGHT SIDE PROPERTY LINE. IN ADDITION BEFORE FINAL ROW INSPECTION THE SWALES TO THE LEFT AND RIGHT WILL NEED TO SODDED AND CULVERTS CLEARED OUT DUE TO THE DRAINAGE INSPECTIONS DURING CONSTRUCTION. THE DEAD SOD AND SEDIMENT IN CULVERTS IS A RESULT OF THE CONSTRUCTION ON 29 PINE GROVE. THIS IS JUST ONE THING THAT WILL NEED TO BE CORRECTED BEFORE FINAL ROW. THAT DOES NOT MEAN THAT THERE MAY BE OTHER CONDITIONS THAT WILL REQUIRE CORRECTING AT THAT TIME. 2/22/2024 - PREVIOUS INSPECTION NOTES 2/22/24 UPON WALKING PROPERTY. RIGHT SIDE PROPERTY LINE OUTLINED IN WHITE PAINT NEED TO CREATE A BERM/SWALE TO KEEP WATER MOVING FORWARD AND HAVE POSITIVE FLOW WITHOUT IMPACTING ADJOINING PROPERTY OWNER. LEFT REAR CORNER WHERE IT IS OUTLINED YOU WILL NEED TO CREATE A BIGGER BERM AROUND THE REAR PROPERTY CORNER AND DOWN THE PROPERTY LINE. IN THE FRONT LEFT CORNER AT MOST FORWARD PEP TANK WATER WILL POOL. NEED TO DETERMINE A WAY TO MOVE IT AROUND ATT BOX INTO FRONT SWALE. Inspector Notes from Inspection 9463 2/22/24 APPROVED AS NOTED THAT SWALE HAS FLOW. 2/9/2024 - PREVIOUS INSPECTION NOTES 2/9/24 RIGHT SIDE SWALE ELEVATION SHOWS 24.0 COMING OUT OF CULVERT GOING UP TO A 24.5 (5 TENTHS THEN 24.4 SHOWING THAT WATER WILL NOT BE ABLE TO HAVE POSITIVE DRAINAGE IN THE SWALE. THIS WILL ALLOW THE SWALE TO BACK UP UPSTREAM. I WILL NOT FEE YOU TODAY, BUT YOU NEED TO MAKE A SWALE ELEVATION CORRECTION IN THE FIELD TO BRING THESE NUMBERS TO POSITIVE DOWNSTREAM FLOW. 11/17/2023 - PREVIOUS INSPECTION NOTES THE ROADSIDE SWALE DOES NOT FLOW IN THE CORRECT WAY NEED TO FIX SO WATER WILL FLOW FROM LEFT TO RIGHT
U -UTILITY RESIDENTIAL FINAL 05/29/2024 FINAL APPROVED LFITZGERALD
Note: 5/22/2024 - PREVIOUS INSPECTION NOTES *** NOTES ADDED BY LFITZGERALD 5/22/2024 11:06:03 AM *** FRONT PEP TANK IS FULL-need access to garage to check breaker-if off please switch on so tank can draw down Inspector Notes from Inspection 9035 both A/B units with potable irrigation with PVB -no cross connection
BLD - BUILDING FINAL 05/29/2024 Disapproved - NO FEE RSIMS
Note: 5/29/24: Walked with Superintendent. Not Ready for Building Final Inspection. (a full inspection will be needed except for the items checked & approved as listed below. Approved (listed items only): * Smoke alarms / Insulation / AHU (in attic) & Condenser (installation only as energy calcs do not match & condensate lines are not 6" above grade) / B side dryer exhaust gooseneck - A side still has screen installed.
ELECTRIC TEMP POLE 05/22/2024 CANCELLED BY INSPECTOR RMARTIN
Note: Inspector Notes from Inspection 2190 Emailed FPL @ 1338. Release Power
U -UTILITY RESIDENTIAL FINAL 05/22/2024 Disapproved - NO FEE LFITZGERALD
Note: *** NOTES ADDED BY LFITZGERALD 5/22/2024 11:06:03 AM *** FRONT PEP TANK IS FULL-need access to garage to check breaker-if off please switch on so tank can draw down Inspector Notes from Inspection 9035 both A/B units with potable irrigation with PVB -no cross connection
ROW - FINAL INSPECTION 05/22/2024 Disapproved -FEE REQUIRED FSLADISH
Note: Inspector Notes from Inspection 9465 5/22/24 READ PREVIOUS INSPECTION NOTES. AS MENTIONED ON THE FINAL SURVEY INSPECTION YOUR RIGHT SIDE FRONT SWALE ELEVATIONS (24.6) ARE HIGHER THAN THE LEFT SIDE (24.3) FLOW IS LEFT TO RIGHT, YOU WILL NEED TO BRING THE SWALE DOWN 3 TENTHS ON THE RIGHT AND RUN IT FLAT AT 24.3 TO MATCH THE GRADE AT THE ADJOINING PROPERTY LINE. I AM APPROVING THIS FIELD SURVEY AS NOTED, CORRECTIONS REQUIRED NEED TO BE MADE BEFORE ROW FINAL SUBMITTAL. AREA HIGHLIGHTED IN WHITE PAINT THAT NEEDS CORRECTION. 5/21/24 UPON WALKING PROPERTY DETERMINED DRAINAGE WILL NOW FLOW AROUND PEP TANK AND REACH THE FRONT SWALE. AS MENTIONED ON THE FINAL SURVEY INSPECTION YOUR RIGHT SIDE FRONT SWALE ELEVATIONS (24.6) ARE HIGHER THAN THE LEFT SIDE (24.3) FLOW IS LEFT TO RIGHT, YOU WILL NEED TO BRING THE SWALE DOWN 3 TENTHS ON THE RIGHT AND RUN IT FLAT AT 24.3 TO MATCH THE GRADE AT THE ADJOINING PROPERTY LINE. I AM APPROVING THIS FIELD SURVEY AS NOTED, CORRECTIONS REQUIRED NEED TO BE MADE BEFORE ROW FINAL SUBMITTAL. ______________________________________________________________________________________________________________________ Inspector Notes from Inspection 9463 5/21/24 PEP TANK DRAINAGE ELEVATION ISSUE CORRECTED. YOU ARE SHOWING THE RIGHT SIDE FRONT SWALE lOW SIDE) 3 TENTHS HIGHER THAN THE LEFT SIDE SWALE. WILL DETERMINE IF THIS IS CORRECT DURING FIELD SURVEY INSPECTION. APPROVING THIS FINAL SURVEY AS NOTED THAT FIELD CORRECTIONS MAY BE REQUIRED. 4/1/2024 - PREVIOUS INSPECTION NOTES 04/01/24 THERE WERE SOME CORRECTIONS MADE FROM PREVIOUS INSPECTION. THE AREA AROUND THE PEP TANK AND THE BACK LEFT CORNERS WILL WORK. THE AREA THAT WAS IN QUESTION ON THE BACK RIGHT WAS DUG TOO DEEP. THERRE IS NOW A LOW AREA THAT WILL HOLD WATER. IF YOU FEEL THIS IS NOT THE CASE PLEASE SUBMIT ANOTHER FINAL SURVEY WITH NEW ELEVATIONS INDICATING PROPER DRAINAGE ALONG RIGHT SIDE PROPERTY LINE. IN ADDITION BEFORE FINAL ROW INSPECTION THE SWALES TO THE LEFT AND RIGHT WILL NEED TO SODDED AND CULVERTS CLEARED OUT DUE TO THE DRAINAGE INSPECTIONS DURING CONSTRUCTION. THE DEAD SOD AND SEDIMENT IN CULVERTS IS A RESULT OF THE CONSTRUCTION ON 29 PINE GROVE. THIS IS JUST ONE THING THAT WILL NEED TO BE CORRECTED BEFORE FINAL ROW. THAT DOES NOT MEAN THAT THERE MAY BE OTHER CONDITIONS THAT WILL REQUIRE CORRECTING AT THAT TIME. 2/22/2024 - PREVIOUS INSPECTION NOTES 2/22/24 UPON WALKING PROPERTY. RIGHT SIDE PROPERTY LINE OUTLINED IN WHITE PAINT NEED TO CREATE A BERM/SWALE TO KEEP WATER MOVING FORWARD AND HAVE POSITIVE FLOW WITHOUT IMPACTING ADJOINING PROPERTY OWNER. LEFT REAR CORNER WHERE IT IS OUTLINED YOU WILL NEED TO CREATE A BIGGER BERM AROUND THE REAR PROPERTY CORNER AND DOWN THE PROPERTY LINE. IN THE FRONT LEFT CORNER AT MOST FORWARD PEP TANK WATER WILL POOL. NEED TO DETERMINE A WAY TO MOVE IT AROUND ATT BOX INTO FRONT SWALE. Inspector Notes from Inspection 9463 2/22/24 APPROVED AS NOTED THAT SWALE HAS FLOW. 2/9/2024 - PREVIOUS INSPECTION NOTES 2/9/24 RIGHT SIDE SWALE ELEVATION SHOWS 24.0 COMING OUT OF CULVERT GOING UP TO A 24.5 (5 TENTHS THEN 24.4 SHOWING THAT WATER WILL NOT BE ABLE TO HAVE POSITIVE DRAINAGE IN THE SWALE. THIS WILL ALLOW THE SWALE TO BACK UP UPSTREAM. I WILL NOT FEE YOU TODAY, BUT YOU NEED TO MAKE A SWALE ELEVATION CORRECTION IN THE FIELD TO BRING THESE NUMBERS TO POSITIVE DOWNSTREAM FLOW. 11/17/2023 - PREVIOUS INSPECTION NOTES THE ROADSIDE SWALE DOES NOT FLOW IN THE CORRECT WAY NEED TO FIX SO WATER WILL FLOW FROM LEFT TO RIGHT
ROW - FINAL APRON (AFTER POUR) 05/22/2024 APPROVED - AS NOTED FSLADISH
Note: 5/22/24 PIPE ELEVATION IS GOOD CUTS MADE. CULVERT CLEAR. HOT PATCH COMPLETED AT THE TIME OF THIS INSPECTION. I AM APPROVING THIS INSPECTION AS NOTED THAT THERE IS A CRACK IN THE DRIVEWAY THAT YOU WILL BE RESPONSIBLE FOR AFTER THIS APPROVAL PHOTO FOR REFERENCE. ________________________________________________________________________________________________________________________ Inspector Notes from Inspection 9465 5/21/24 UPON WALKING PROPERTY DETERMINED DRAINAGE WILL NOW FLOW AROUND PEP TANK AND REACH THE FRONT SWALE. AS MENTIONED ON THE FINAL SURVEY INSPECTION YOUR RIGHT SIDE FRONT SWALE ELEVATIONS (24.6) ARE HIGHER THAN THE LEFT SIDE (24.3) FLOW IS LEFT TO RIGHT, YOU WILL NEED TO BRING THE SWALE DOWN 3 TENTHS ON THE RIGHT AND RUN IT FLAT AT 24.3 TO MATCH THE GRADE AT THE ADJOINING PROPERTY LINE. I AM APPROVING THIS FIELD SURVEY AS NOTED, CORRECTIONS REQUIRED NEED TO BE MADE BEFORE ROW FINAL SUBMITTAL. ______________________________________________________________________________________________________________________ Inspector Notes from Inspection 9463 5/21/24 PEP TANK DRAINAGE ELEVATION ISSUE CORRECTED. YOU ARE SHOWING THE RIGHT SIDE FRONT SWALE lOW SIDE) 3 TENTHS HIGHER THAN THE LEFT SIDE SWALE. WILL DETERMINE IF THIS IS CORRECT DURING FIELD SURVEY INSPECTION. APPROVING THIS FINAL SURVEY AS NOTED THAT FIELD CORRECTIONS MAY BE REQUIRED. 4/1/2024 - PREVIOUS INSPECTION NOTES 04/01/24 THERE WERE SOME CORRECTIONS MADE FROM PREVIOUS INSPECTION. THE AREA AROUND THE PEP TANK AND THE BACK LEFT CORNERS WILL WORK. THE AREA THAT WAS IN QUESTION ON THE BACK RIGHT WAS DUG TOO DEEP. THERRE IS NOW A LOW AREA THAT WILL HOLD WATER. IF YOU FEEL THIS IS NOT THE CASE PLEASE SUBMIT ANOTHER FINAL SURVEY WITH NEW ELEVATIONS INDICATING PROPER DRAINAGE ALONG RIGHT SIDE PROPERTY LINE. IN ADDITION BEFORE FINAL ROW INSPECTION THE SWALES TO THE LEFT AND RIGHT WILL NEED TO SODDED AND CULVERTS CLEARED OUT DUE TO THE DRAINAGE INSPECTIONS DURING CONSTRUCTION. THE DEAD SOD AND SEDIMENT IN CULVERTS IS A RESULT OF THE CONSTRUCTION ON 29 PINE GROVE. THIS IS JUST ONE THING THAT WILL NEED TO BE CORRECTED BEFORE FINAL ROW. THAT DOES NOT MEAN THAT THERE MAY BE OTHER CONDITIONS THAT WILL REQUIRE CORRECTING AT THAT TIME. 2/22/2024 - PREVIOUS INSPECTION NOTES 2/22/24 UPON WALKING PROPERTY. RIGHT SIDE PROPERTY LINE OUTLINED IN WHITE PAINT NEED TO CREATE A BERM/SWALE TO KEEP WATER MOVING FORWARD AND HAVE POSITIVE FLOW WITHOUT IMPACTING ADJOINING PROPERTY OWNER. LEFT REAR CORNER WHERE IT IS OUTLINED YOU WILL NEED TO CREATE A BIGGER BERM AROUND THE REAR PROPERTY CORNER AND DOWN THE PROPERTY LINE. IN THE FRONT LEFT CORNER AT MOST FORWARD PEP TANK WATER WILL POOL. NEED TO DETERMINE A WAY TO MOVE IT AROUND ATT BOX INTO FRONT SWALE. Inspector Notes from Inspection 9463 2/22/24 APPROVED AS NOTED THAT SWALE HAS FLOW. 2/9/2024 - PREVIOUS INSPECTION NOTES 2/9/24 RIGHT SIDE SWALE ELEVATION SHOWS 24.0 COMING OUT OF CULVERT GOING UP TO A 24.5 (5 TENTHS THEN 24.4 SHOWING THAT WATER WILL NOT BE ABLE TO HAVE POSITIVE DRAINAGE IN THE SWALE. THIS WILL ALLOW THE SWALE TO BACK UP UPSTREAM. I WILL NOT FEE YOU TODAY, BUT YOU NEED TO MAKE A SWALE ELEVATION CORRECTION IN THE FIELD TO BRING THESE NUMBERS TO POSITIVE DOWNSTREAM FLOW. 11/17/2023 - PREVIOUS INSPECTION NOTES THE ROADSIDE SWALE DOES NOT FLOW IN THE CORRECT WAY NEED TO FIX SO WATER WILL FLOW FROM LEFT TO RIGHT Inspector Notes from Inspection 9465 5/21/24 UPON WALKING PROPERTY DETERMINED DRAINAGE WILL NOW FLOW AROUND PEP TANK AND REACH THE FRONT SWALE. AS MENTIONED ON THE FINAL SURVEY INSPECTION YOUR RIGHT SIDE FRONT SWALE ELEVATIONS (24.6) ARE HIGHER THAN THE LEFT SIDE (24.3) FLOW IS LEFT TO RIGHT, YOU WILL NEED TO BRING THE SWALE DOWN 3 TENTHS ON THE RIGHT AND RUN IT FLAT AT 24.3 TO MATCH THE GRADE AT THE ADJOINING PROPERTY LINE. I AM APPROVING THIS FIELD SURVEY AS NOTED, CORRECTIONS REQUIRED NEED TO BE MADE BEFORE ROW FINAL SUBMITTAL. ______________________________________________________________________________________________________________________ Inspector Notes from Inspection 9463 5/21/24 PEP TANK DRAINAGE ELEVATION ISSUE CORRECTED. YOU ARE SHOWING THE RIGHT SIDE FRONT SWALE lOW SIDE) 3 TENTHS HIGHER THAN THE LEFT SIDE SWALE. WILL DETERMINE IF THIS IS CORRECT DURING FIELD SURVEY INSPECTION. APPROVING THIS FINAL SURVEY AS NOTED THAT FIELD CORRECTIONS MAY BE REQUIRED. 4/1/2024 - PREVIOUS INSPECTION NOTES 04/01/24 THERE WERE SOME CORRECTIONS MADE FROM PREVIOUS INSPECTION. THE AREA AROUND THE PEP TANK AND THE BACK LEFT CORNERS WILL WORK. THE AREA THAT WAS IN QUESTION ON THE BACK RIGHT WAS DUG TOO DEEP. THERRE IS NOW A LOW AREA THAT WILL HOLD WATER. IF YOU FEEL THIS IS NOT THE CASE PLEASE SUBMIT ANOTHER FINAL SURVEY WITH NEW ELEVATIONS INDICATING PROPER DRAINAGE ALONG RIGHT SIDE PROPERTY LINE. IN ADDITION BEFORE FINAL ROW INSPECTION THE SWALES TO THE LEFT AND RIGHT WILL NEED TO SODDED AND CULVERTS CLEARED OUT DUE TO THE DRAINAGE INSPECTIONS DURING CONSTRUCTION. THE DEAD SOD AND SEDIMENT IN CULVERTS IS A RESULT OF THE CONSTRUCTION ON 29 PINE GROVE. THIS IS JUST ONE THING THAT WILL NEED TO BE CORRECTED BEFORE FINAL ROW. THAT DOES NOT MEAN THAT THERE MAY BE OTHER CONDITIONS THAT WILL REQUIRE CORRECTING AT THAT TIME. 2/22/2024 - PREVIOUS INSPECTION NOTES 2/22/24 UPON WALKING PROPERTY. RIGHT SIDE PROPERTY LINE OUTLINED IN WHITE PAINT NEED TO CREATE A BERM/SWALE TO KEEP WATER MOVING FORWARD AND HAVE POSITIVE FLOW WITHOUT IMPACTING ADJOINING PROPERTY OWNER. LEFT REAR CORNER WHERE IT IS OUTLINED YOU WILL NEED TO CREATE A BIGGER BERM AROUND THE REAR PROPERTY CORNER AND DOWN THE PROPERTY LINE. IN THE FRONT LEFT CORNER AT MOST FORWARD PEP TANK WATER WILL POOL. NEED TO DETERMINE A WAY TO MOVE IT AROUND ATT BOX INTO FRONT SWALE. Inspector Notes from Inspection 9463 2/22/24 APPROVED AS NOTED THAT SWALE HAS FLOW. 2/9/2024 - PREVIOUS INSPECTION NOTES 2/9/24 RIGHT SIDE SWALE ELEVATION SHOWS 24.0 COMING OUT OF CULVERT GOING UP TO A 24.5 (5 TENTHS THEN 24.4 SHOWING THAT WATER WILL NOT BE ABLE TO HAVE POSITIVE DRAINAGE IN THE SWALE. THIS WILL ALLOW THE SWALE TO BACK UP UPSTREAM. I WILL NOT FEE YOU TODAY, BUT YOU NEED TO MAKE A SWALE ELEVATION CORRECTION IN THE FIELD TO BRING THESE NUMBERS TO POSITIVE DOWNSTREAM FLOW. 11/17/2023 - PREVIOUS INSPECTION NOTES THE ROADSIDE SWALE DOES NOT FLOW IN THE CORRECT WAY NEED TO FIX SO WATER WILL FLOW FROM LEFT TO RIGHT
ROW- FINAL SURVEY/GRADING CERTIFICATION 05/21/2024 APPROVED - AS NOTED FSLADISH
Note: 5/21/24 PEP TANK DRAINAGE ELEVATION ISSUE CORRECTED. YOU ARE SHOWING THE RIGHT SIDE FRONT SWALE lOW SIDE) 3 TENTHS HIGHER THAN THE LEFT SIDE SWALE. WILL DETERMINE IF THIS IS CORRECT DURING FIELD SURVEY INSPECTION. APPROVING THIS FINAL SURVEY AS NOTED THAT FIELD CORRECTIONS MAY BE REQUIRED.
ROW FIELD SURVEY /GRADING CERTIFICATION 05/21/2024 APPROVED - AS NOTED FSLADISH
Note: 5/21/24 UPON WALKING PROPERTY DETERMINED DRAINAGE WILL NOW FLOW AROUND PEP TANK AND REACH THE FRONT SWALE. AS MENTIONED ON THE FINAL SURVEY INSPECTION YOUR RIGHT SIDE FRONT SWALE ELEVATIONS (24.6) ARE HIGHER THAN THE LEFT SIDE (24.3) FLOW IS LEFT TO RIGHT, YOU WILL NEED TO BRING THE SWALE DOWN 3 TENTHS ON THE RIGHT AND RUN IT FLAT AT 24.3 TO MATCH THE GRADE AT THE ADJOINING PROPERTY LINE. I AM APPROVING THIS FIELD SURVEY AS NOTED, CORRECTIONS REQUIRED NEED TO BE MADE BEFORE ROW FINAL SUBMITTAL. ______________________________________________________________________________________________________________________ Inspector Notes from Inspection 9463 5/21/24 PEP TANK DRAINAGE ELEVATION ISSUE CORRECTED. YOU ARE SHOWING THE RIGHT SIDE FRONT SWALE lOW SIDE) 3 TENTHS HIGHER THAN THE LEFT SIDE SWALE. WILL DETERMINE IF THIS IS CORRECT DURING FIELD SURVEY INSPECTION. APPROVING THIS FINAL SURVEY AS NOTED THAT FIELD CORRECTIONS MAY BE REQUIRED. 4/1/2024 - PREVIOUS INSPECTION NOTES 04/01/24 THERE WERE SOME CORRECTIONS MADE FROM PREVIOUS INSPECTION. THE AREA AROUND THE PEP TANK AND THE BACK LEFT CORNERS WILL WORK. THE AREA THAT WAS IN QUESTION ON THE BACK RIGHT WAS DUG TOO DEEP. THERRE IS NOW A LOW AREA THAT WILL HOLD WATER. IF YOU FEEL THIS IS NOT THE CASE PLEASE SUBMIT ANOTHER FINAL SURVEY WITH NEW ELEVATIONS INDICATING PROPER DRAINAGE ALONG RIGHT SIDE PROPERTY LINE. IN ADDITION BEFORE FINAL ROW INSPECTION THE SWALES TO THE LEFT AND RIGHT WILL NEED TO SODDED AND CULVERTS CLEARED OUT DUE TO THE DRAINAGE INSPECTIONS DURING CONSTRUCTION. THE DEAD SOD AND SEDIMENT IN CULVERTS IS A RESULT OF THE CONSTRUCTION ON 29 PINE GROVE. THIS IS JUST ONE THING THAT WILL NEED TO BE CORRECTED BEFORE FINAL ROW. THAT DOES NOT MEAN THAT THERE MAY BE OTHER CONDITIONS THAT WILL REQUIRE CORRECTING AT THAT TIME. 2/22/2024 - PREVIOUS INSPECTION NOTES 2/22/24 UPON WALKING PROPERTY. RIGHT SIDE PROPERTY LINE OUTLINED IN WHITE PAINT NEED TO CREATE A BERM/SWALE TO KEEP WATER MOVING FORWARD AND HAVE POSITIVE FLOW WITHOUT IMPACTING ADJOINING PROPERTY OWNER. LEFT REAR CORNER WHERE IT IS OUTLINED YOU WILL NEED TO CREATE A BIGGER BERM AROUND THE REAR PROPERTY CORNER AND DOWN THE PROPERTY LINE. IN THE FRONT LEFT CORNER AT MOST FORWARD PEP TANK WATER WILL POOL. NEED TO DETERMINE A WAY TO MOVE IT AROUND ATT BOX INTO FRONT SWALE. Inspector Notes from Inspection 9463 2/22/24 APPROVED AS NOTED THAT SWALE HAS FLOW. 2/9/2024 - PREVIOUS INSPECTION NOTES 2/9/24 RIGHT SIDE SWALE ELEVATION SHOWS 24.0 COMING OUT OF CULVERT GOING UP TO A 24.5 (5 TENTHS THEN 24.4 SHOWING THAT WATER WILL NOT BE ABLE TO HAVE POSITIVE DRAINAGE IN THE SWALE. THIS WILL ALLOW THE SWALE TO BACK UP UPSTREAM. I WILL NOT FEE YOU TODAY, BUT YOU NEED TO MAKE A SWALE ELEVATION CORRECTION IN THE FIELD TO BRING THESE NUMBERS TO POSITIVE DOWNSTREAM FLOW. 11/17/2023 - PREVIOUS INSPECTION NOTES THE ROADSIDE SWALE DOES NOT FLOW IN THE CORRECT WAY NEED TO FIX SO WATER WILL FLOW FROM LEFT TO RIGHT
ROW FIELD SURVEY /GRADING CERTIFICATION 04/01/2024 Disapproved - NO FEE TPOLACEK
Note: 04/01/24 THERE WERE SOME CORRECTIONS MADE FROM PREVIOUS INSPECTION. THE AREA AROUND THE PEP TANK AND THE BACK LEFT CORNERS WILL WORK. THE AREA THAT WAS IN QUESTION ON THE BACK RIGHT WAS DUG TOO DEEP. THERRE IS NOW A LOW AREA THAT WILL HOLD WATER. IF YOU FEEL THIS IS NOT THE CASE PLEASE SUBMIT ANOTHER FINAL SURVEY WITH NEW ELEVATIONS INDICATING PROPER DRAINAGE ALONG RIGHT SIDE PROPERTY LINE. IN ADDITION BEFORE FINAL ROW INSPECTION THE SWALES TO THE LEFT AND RIGHT WILL NEED TO SODDED AND CULVERTS CLEARED OUT DUE TO THE DRAINAGE INSPECTIONS DURING CONSTRUCTION. THE DEAD SOD AND SEDIMENT IN CULVERTS IS A RESULT OF THE CONSTRUCTION ON 29 PINE GROVE. THIS IS JUST ONE THING THAT WILL NEED TO BE CORRECTED BEFORE FINAL ROW. THAT DOES NOT MEAN THAT THERE MAY BE OTHER CONDITIONS THAT WILL REQUIRE CORRECTING AT THAT TIME. 2/22/2024 - PREVIOUS INSPECTION NOTES 2/22/24 UPON WALKING PROPERTY. RIGHT SIDE PROPERTY LINE OUTLINED IN WHITE PAINT NEED TO CREATE A BERM/SWALE TO KEEP WATER MOVING FORWARD AND HAVE POSITIVE FLOW WITHOUT IMPACTING ADJOINING PROPERTY OWNER. LEFT REAR CORNER WHERE IT IS OUTLINED YOU WILL NEED TO CREATE A BIGGER BERM AROUND THE REAR PROPERTY CORNER AND DOWN THE PROPERTY LINE. IN THE FRONT LEFT CORNER AT MOST FORWARD PEP TANK WATER WILL POOL. NEED TO DETERMINE A WAY TO MOVE IT AROUND ATT BOX INTO FRONT SWALE. Inspector Notes from Inspection 9463 2/22/24 APPROVED AS NOTED THAT SWALE HAS FLOW. 2/9/2024 - PREVIOUS INSPECTION NOTES 2/9/24 RIGHT SIDE SWALE ELEVATION SHOWS 24.0 COMING OUT OF CULVERT GOING UP TO A 24.5 (5 TENTHS THEN 24.4 SHOWING THAT WATER WILL NOT BE ABLE TO HAVE POSITIVE DRAINAGE IN THE SWALE. THIS WILL ALLOW THE SWALE TO BACK UP UPSTREAM. I WILL NOT FEE YOU TODAY, BUT YOU NEED TO MAKE A SWALE ELEVATION CORRECTION IN THE FIELD TO BRING THESE NUMBERS TO POSITIVE DOWNSTREAM FLOW. 11/17/2023 - PREVIOUS INSPECTION NOTES THE ROADSIDE SWALE DOES NOT FLOW IN THE CORRECT WAY NEED TO FIX SO WATER WILL FLOW FROM LEFT TO RIGHT
ROW- FINAL SURVEY/GRADING CERTIFICATION 02/22/2024 APPROVED - AS NOTED FSLADISH
Note: 2/22/24 APPROVED AS NOTED THAT SWALE HAS FLOW. 2/9/2024 - PREVIOUS INSPECTION NOTES 2/9/24 RIGHT SIDE SWALE ELEVATION SHOWS 24.0 COMING OUT OF CULVERT GOING UP TO A 24.5 (5 TENTHS THEN 24.4 SHOWING THAT WATER WILL NOT BE ABLE TO HAVE POSITIVE DRAINAGE IN THE SWALE. THIS WILL ALLOW THE SWALE TO BACK UP UPSTREAM. I WILL NOT FEE YOU TODAY, BUT YOU NEED TO MAKE A SWALE ELEVATION CORRECTION IN THE FIELD TO BRING THESE NUMBERS TO POSITIVE DOWNSTREAM FLOW. 11/17/2023 - PREVIOUS INSPECTION NOTES THE ROADSIDE SWALE DOES NOT FLOW IN THE CORRECT WAY NEED TO FIX SO WATER WILL FLOW FROM LEFT TO RIGHT
ROW FIELD SURVEY /GRADING CERTIFICATION 02/22/2024 Disapproved - NO FEE FSLADISH
Note: 2/22/24 UPON WALKING PROPERTY. RIGHT SIDE PROPERTY LINE OUTLINED IN WHITE PAINT NEED TO CREATE A BERM/SWALE TO KEEP WATER MOVING FORWARD AND HAVE POSITIVE FLOW WITHOUT IMPACTING ADJOINING PROPERTY OWNER. LEFT REAR CORNER WHERE IT IS OUTLINED YOU WILL NEED TO CREATE A BIGGER BERM AROUND THE REAR PROPERTY CORNER AND DOWN THE PROPERTY LINE. IN THE FRONT LEFT CORNER AT MOST FORWARD PEP TANK WATER WILL POOL. NEED TO DETERMINE A WAY TO MOVE IT AROUND ATT BOX INTO FRONT SWALE. Inspector Notes from Inspection 9463 2/22/24 APPROVED AS NOTED THAT SWALE HAS FLOW. 2/9/2024 - PREVIOUS INSPECTION NOTES 2/9/24 RIGHT SIDE SWALE ELEVATION SHOWS 24.0 COMING OUT OF CULVERT GOING UP TO A 24.5 (5 TENTHS THEN 24.4 SHOWING THAT WATER WILL NOT BE ABLE TO HAVE POSITIVE DRAINAGE IN THE SWALE. THIS WILL ALLOW THE SWALE TO BACK UP UPSTREAM. I WILL NOT FEE YOU TODAY, BUT YOU NEED TO MAKE A SWALE ELEVATION CORRECTION IN THE FIELD TO BRING THESE NUMBERS TO POSITIVE DOWNSTREAM FLOW. 11/17/2023 - PREVIOUS INSPECTION NOTES THE ROADSIDE SWALE DOES NOT FLOW IN THE CORRECT WAY NEED TO FIX SO WATER WILL FLOW FROM LEFT TO RIGHT
ROW FIELD SURVEY /GRADING CERTIFICATION 02/12/2024 CANCELLED BY APPLICANT WEB
ROW- FINAL SURVEY/GRADING CERTIFICATION 02/09/2024 Disapproved - NO FEE FSLADISH
Note: 2/9/24 RIGHT SIDE SWALE ELEVATION SHOWS 24.0 COMING OUT OF CULVERT GOING UP TO A 24.5 (5 TENTHS THEN 24.4 SHOWING THAT WATER WILL NOT BE ABLE TO HAVE POSITIVE DRAINAGE IN THE SWALE. THIS WILL ALLOW THE SWALE TO BACK UP UPSTREAM. I WILL NOT FEE YOU TODAY, BUT YOU NEED TO MAKE A SWALE ELEVATION CORRECTION IN THE FIELD TO BRING THESE NUMBERS TO POSITIVE DOWNSTREAM FLOW. 11/17/2023 - PREVIOUS INSPECTION NOTES THE ROADSIDE SWALE DOES NOT FLOW IN THE CORRECT WAY NEED TO FIX SO WATER WILL FLOW FROM LEFT TO RIGHT
FIREWALL FINAL 12/01/2023 APPROVED KSANDOE
U-CROSS CONNECTION 12/01/2023 APPROVED - AS NOTED LFITZGERALD
Note: both A/B units with potable irrigation with PVB -no cross connection
ROW- FINAL SURVEY/GRADING CERTIFICATION 11/17/2023 Disapproved - NO FEE PFLANAGAN
Note: THE ROADSIDE SWALE DOES NOT FLOW IN THE CORRECT WAY NEED TO FIX SO WATER WILL FLOW FROM LEFT TO RIGHT
ROW- PRE-APRON (PRE-POUR) 10/18/2023 APPROVED PFLANAGAN
Note: IT'S YOUR RESPONSIBILITY TO CHECK THE CULVERT ELEVATIONS BEFORE POURING CONCRETE ALL CONCRETE NEEDS TO BE A MINIMUM OF 3000PSI WITH FIBER OR WITH METAL MESH IN THE CONCRETE TO MEET ALL CITY'S STANDARTS At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved. -------------------------------------------------------------------------- 10/17/2023 - PREVIOUS INSPECTION NOTES CULVERT PIPE IS PITCHED THE WRONG WAY Sec 300.01c3 The driveway culvert(s) must be set within the range established by the Swale Plan. The culvert cannot be sloped against the drainage flow ------------------------------------------------------------------------------- 10/12/2023 - PREVIOUS INSPECTION NOTES Inspector Notes from Inspection 9470 05/09/23 PIPE IS UNDER DIRT AND MATCHES SWALE GRADE. SWALE IS OPEN TO FLOW. BUILDER WILL NEED TO ENSURE SWALE IS KEPT OPEN AND PIPE HAS FLOW DURING CONSTRUCTION PROCESS. ___________________________________________________________________________________________________________________________ 5/2/2023 - PREVIOUS INSPECTION NOTES 5/2/23= they need to lower the HDPE pipe like 5 inches in the ground the plastic HDPE is above the ground . INSPECTOR BE BACK ON 5/9/23 ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 4/26/ 2023 - PREVIOUS INSPECTION NOTES 04/26/23= Builder needs to keep the swale drainage open during the entire course of construction. Either by regrading every day or installing a temporary pipe and maintaining it to allow for drainage. Next inspection 5/2/23 PICTURE ATTACHED
ROW- PRE-APRON (PRE-POUR) 10/17/2023 Disapproved -FEE REQUIRED PFLANAGAN
Note: CULVERT PIPE IS PITCHED THE WRONG WAY Sec 300.01c3 The driveway culvert(s) must be set within the range established by the Swale Plan. The culvert cannot be sloped against the drainage flow ------------------------------------------------------------------------------- 10/12/2023 - PREVIOUS INSPECTION NOTES Inspector Notes from Inspection 9470 05/09/23 PIPE IS UNDER DIRT AND MATCHES SWALE GRADE. SWALE IS OPEN TO FLOW. BUILDER WILL NEED TO ENSURE SWALE IS KEPT OPEN AND PIPE HAS FLOW DURING CONSTRUCTION PROCESS. ___________________________________________________________________________________________________________________________ 5/2/2023 - PREVIOUS INSPECTION NOTES 5/2/23= they need to lower the HDPE pipe like 5 inches in the ground the plastic HDPE is above the ground . INSPECTOR BE BACK ON 5/9/23 ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 4/26/ 2023 - PREVIOUS INSPECTION NOTES 04/26/23= Builder needs to keep the swale drainage open during the entire course of construction. Either by regrading every day or installing a temporary pipe and maintaining it to allow for drainage. Next inspection 5/2/23 PICTURE ATTACHED
ROW- PRE-APRON (PRE-POUR) 10/12/2023 CANCELLED BY APPLICANT PFLANAGAN
Note: Inspector Notes from Inspection 9470 05/09/23 PIPE IS UNDER DIRT AND MATCHES SWALE GRADE. SWALE IS OPEN TO FLOW. BUILDER WILL NEED TO ENSURE SWALE IS KEPT OPEN AND PIPE HAS FLOW DURING CONSTRUCTION PROCESS. ___________________________________________________________________________________________________________________________ 5/2/2023 - PREVIOUS INSPECTION NOTES 5/2/23= they need to lower the HDPE pipe like 5 inches in the ground the plastic HDPE is above the ground . INSPECTOR BE BACK ON 5/9/23 ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 4/26/ 2023 - PREVIOUS INSPECTION NOTES 04/26/23= Builder needs to keep the swale drainage open during the entire course of construction. Either by regrading every day or installing a temporary pipe and maintaining it to allow for drainage. Next inspection 5/2/23 PICTURE ATTACHED
GRAVITY SEWER TEST 10/11/2023 APPROVED - AS NOTED MGIBSON
Note: Inspector Notes from Inspection 2060 Swale area needs to be maintained clear for stormwater drainage at all times NEXT TIME GRAVITY SEWER NEEDS TO BE LEFT OPE FOR INSPECTION SWELL NEEDS ATTENTION STILL 4/27/2023 - PREVIOUS INSPECTION NOTES
U - SEWER TIE IN 10/11/2023 APPROVED MGIBSON
Note: Inspector Notes from Inspection 2060 Swale area needs to be maintained clear for stormwater drainage at all times 4/27/2023 - PREVIOUS INSPECTION NOTES
ELECTRIC - EARLY POWER 10/03/2023 APPROVED - AS NOTED KSANDOE
Note: Emailed FPL @ 1338. Release Power
PEP TANK INSTALLATION REQUEST 09/14/2023 APPROVED CBOWERMASTER
Note: 9/13/2023 7:40:22 AM- PREVIOUS INSPECTION NOTES dumpster
PEP TANK INSTALLATION REQUEST 09/12/2023 Disapproved -FEE REQUIRED CBOWERMASTER
Note: dumpster
ELECTRIC TEMP POLE 08/03/2023 Disapproved - NO FEE KSANDOE
Note: Contact inspector. Ken 386-986-9364
INSULATION 07/28/2023 APPROVED KSANDOE
FIREWALL DRYWALL NAILING 07/25/2023 APPROVED KSANDOE
LATH/BRICK/ WATER BARRIER 07/21/2023 APPROVED KSANDOE
Note: Inspector Notes from Inspection 2420 Please clean up jobsite of all garbage and debris front and rear
ALL ROUGH 07/19/2023 APPROVED - AS NOTED TSTAUFFACHER
Note: Please clean up jobsite of all garbage and debris front and rear
ROOF SHEATHING / BRACES/TIES/DOWN CELL 07/18/2023 APPROVED KSANDOE
Note: 7/14/2023 - PREVIOUS INSPECTION NOTES No address posted. Need truss packet on site for inspection 7/11/2023 - PREVIOUS INSPECTION NOTES 7/7/2023 - PREVIOUS INSPECTION NOTES Not ready for inspection. Crews working 7/11/23 - COULDN'T INSPECT. 6 ELECTRICIANS WORKING. PULLING WIRE INSTALL BOXES ETC. MULTIPLE TRIP HAZARDS ON THE FLOOR. THERE TOOLS PLUS EQUIPMENT, SUPPLIES, LADDERS, WIRES etc...
ROOF SHEATHING / BRACES/TIES/DOWN CELL 07/14/2023 Disapproved -FEE REQUIRED KSANDOE
Note: No address posted. Need truss packet on site for inspection 7/11/2023 - PREVIOUS INSPECTION NOTES 7/7/2023 - PREVIOUS INSPECTION NOTES Not ready for inspection. Crews working 7/11/23 - COULDN'T INSPECT. 6 ELECTRICIANS WORKING. PULLING WIRE INSTALL BOXES ETC. MULTIPLE TRIP HAZARDS ON THE FLOOR. THERE TOOLS PLUS EQUIPMENT, SUPPLIES, LADDERS, WIRES etc...
ROOF SHEATHING / BRACES/TIES/DOWN CELL 07/11/2023 Disapproved - NO FEE FWILLIS
Note: 7/7/2023 - PREVIOUS INSPECTION NOTES Not ready for inspection. Crews working 7/11/23 - COULDN'T INSPECT. 6 ELECTRICIANS WORKING. PULLING WIRE INSTALL BOXES ETC. MULTIPLE TRIP HAZARDS ON THE FLOOR. THERE TOOLS PLUS EQUIPMENT, SUPPLIES, LADDERS, WIRES etc...
ROOF VALLEY & METAL 07/11/2023 APPROVED FWILLIS
Note: 7/7/2023 - PREVIOUS INSPECTION NOTES Not ready for inspection. Crews working
WALL SHEATHING 07/11/2023 APPROVED FWILLIS
Note: 7/7/2023 - PREVIOUS INSPECTION NOTES Not ready for inspection. Crews working
ROOF SHEATHING / BRACES/TIES/DOWN CELL 07/07/2023 Disapproved - NO FEE KSANDOE
Note: Not ready for inspection. Crews working
WALL SHEATHING 07/07/2023 Disapproved - NO FEE KSANDOE
Note: Not ready for inspection. Crews working
ROOF VALLEY & METAL 07/07/2023 Disapproved - NO FEE KSANDOE
Note: Not ready for inspection. Crews working
FOUND SURVEY APPROVED (OFFICE) 07/06/2023 APPROVED CGONCALVES
TIE BEAM / LINTEL 05/15/2023 APPROVED KSANDOE
Note: 5/12/2023 - PREVIOUS INSPECTION NOTES Missing dowel at entry Inspector Notes from Inspection 2250 Please install silt fencing
TIE BEAM / LINTEL 05/12/2023 Disapproved - NO FEE KSANDOE
Note: Missing dowel at entry Inspector Notes from Inspection 2250 Please install silt fencing
ROW - DRAINAGE 05/09/2023 APPROVED - AS NOTED FSLADISH
Note: 05/09/23 PIPE IS UNDER DIRT AND MATCHES SWALE GRADE. SWALE IS OPEN TO FLOW. BUILDER WILL NEED TO ENSURE SWALE IS KEPT OPEN AND PIPE HAS FLOW DURING CONSTRUCTION PROCESS. ___________________________________________________________________________________________________________________________ 5/2/2023 - PREVIOUS INSPECTION NOTES 5/2/23= they need to lower the HDPE pipe like 5 inches in the ground the plastic HDPE is above the ground . INSPECTOR BE BACK ON 5/9/23 ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 4/26/ 2023 - PREVIOUS INSPECTION NOTES 04/26/23= Builder needs to keep the swale drainage open during the entire course of construction. Either by regrading every day or installing a temporary pipe and maintaining it to allow for drainage. Next inspection 5/2/23 PICTURE ATTACHED
MONOLITHIC SLAB 05/04/2023 APPROVED - AS NOTED KSANDOE
Note: Please install silt fencing
ROW - DRAINAGE 05/02/2023 Disapproved - NO FEE GBERTOLA
Note: 5/2/23= they need to lower the HDPE pipe like 5 inches in the ground the plastic HDPE is above the ground . INSPECTOR BE BACK ON 5/9/23 ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 4/26/ 2023 - PREVIOUS INSPECTION NOTES 04/26/23= Builder needs to keep the swale drainage open during the entire course of construction. Either by regrading every day or installing a temporary pipe and maintaining it to allow for drainage. Next inspection 5/2/23 PICTURE ATTACHED
PLUMBING 1ST ROUGH UNDERGROUND 04/28/2023 APPROVED - AS NOTED KSANDOE
Note: Swale area needs to be maintained clear for stormwater drainage at all times 4/27/2023 - PREVIOUS INSPECTION NOTES
PLUMBING 1ST ROUGH UNDERGROUND 04/27/2023 CANCELLED BY APPLICANT KSANDOE
ROW- PROJECT STATUS 04/26/2023 CANCELLED BY INSPECTOR GBERTOLA
ROW - DRAINAGE 04/26/2023 Disapproved -FEE REQUIRED GBERTOLA
Note: 04/26/23= Builder needs to keep the swale drainage open during the entire course of construction. Either by regrading every day or installing a temporary pipe and maintaining it to allow for drainage. Next inspection 5/2/23 PICTURE ATTACHED
WATER METER INSTALLATION REQUEST 04/21/2023 APPROVED CSTONE

Review History

Department Status Date In Date Out
ENGIN1 COMPLETE 09/28/2023 09/29/2023
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
SW1 COMPLETE 09/28/2023 09/29/2023
Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM
ZON COMPLETE 09/28/2023 09/29/2023
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
ZON COMPLETE 07/05/2023 07/05/2023
Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM
ENGIN1 COMPLETE 07/05/2023 07/05/2023
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ENGIN1 COMPLETE 06/13/2023 06/14/2023
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
SW1 COMPLETE 06/13/2023 06/21/2023
Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM
ZON HOLD 06/13/2023 06/13/2023
Note: Held By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM House does not meet the minimum required front setback of 25' on the foundation survey.
SW1 COMPLETE 04/10/2023 04/10/2023
Note: Released By: ROBERT GROSS - (386)986-4769 - RGROSS@PALMCOASTGOV.COM
ENGIN1 COMPLETE 04/10/2023 04/11/2023
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
SW1 COMPLETE 04/10/2023 04/12/2023
Note: Released By: ROBERT GROSS - (386)986-4769 - RGROSS@PALMCOASTGOV.COM
ZON COMPLETE 04/10/2023 04/11/2023
Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM changes for storm water only
ZON COMPLETE 03/31/2023 03/31/2023
Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM
ELEC COMPLETE 03/31/2023 03/31/2023
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
SW1 REJECT 03/31/2023 04/10/2023
Note: Rejected By: ROBERT GROSS - (386)986-4769 - RGROSS@PALMCOASTGOV.COM Grading on both sides need a common swale and directional arrows to show stormwater flow direction.
ENGIN1 COMPLETE 03/31/2023 03/31/2023
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ENGIN1 COMPLETE 03/24/2023 03/24/2023
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ELEC HOLD 03/24/2023 03/27/2023
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 4/0 AL is not rated for the 300 amp service. Submit a new riser diagram. NEC 2017 Table 310.15(B)(16) 2nd REQUEST
BLD COMPLETE 03/24/2023 03/26/2023
Note: Released By: JPI
MECH COMPLETE 03/24/2023 03/27/2023
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
ZON HOLD 03/24/2023 03/24/2023
Note: Held By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM repeat comment Legal description ins incorrect. Map Panel should be 0138E 2 car garage homes driveway width max is 36' you have 40' it exceeds please correct
SW1 HOLD 03/24/2023 03/30/2023
Note: Held By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM NEED TO RESUBMIT A NEW SITE PLAN
SWALE COMPLETE 03/24/2023 05/31/2023
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
BLD HOLD 03/17/2023 03/20/2023
Note: Held By: JPI 1. Provide footing depths on Details2.pdf. R403.1.4 2. Provide UL rating of fire walls. R301
CUSVC COMPLETE 03/17/2023 03/22/2023
Note: Released By: LISA ASBILL - - lasbill@palmcoastgov.com
ELEC HOLD 03/17/2023 03/20/2023
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 4/0 AL is not rated for the 300 amp service. Submit a new riser diagram. NEC 2017 Table 310.15(B)(16)
ENGIN1 HOLD 03/17/2023 03/17/2023
Note: Held By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM All survey elevations must be carried out to the nearest hundredth of a foot
GAS CANCEL 03/17/2023 03/17/2023
LOCATE COMPLETE 03/17/2023 03/21/2023
Note: Released By: CANDACE STONE - - CSTONE@PALMCOASTGOV.COM
MECH HOLD 03/17/2023 03/21/2023
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM 1. Provide typical wall detail from footing to roof on plans showing insulation in attic and walls. 2. Typically block wall has R4.1 to R5 insulation rating. Energy calcs say 11.6. Correct if wall insulation from architect detail is different.
SW1 HOLD 03/17/2023 03/22/2023
Note: Held By: EDWARD MADISON - - EMADISON@PALMCOASTGOV.COM NEED TO CLEARLY DIFFERENTIATE AND IDENTIFY THE DIFFERENCE BETWEEN EXISTING ELEVATIONS AND PROPOSED. ALSO ADJACENT PROPERTIES ON ALL SIDES NEED TO KNOW IF IMPROVED LOTS AND F.F.E. CLEARLY IDENTIFY THE CENTERLINE OF THE ROAD
ZON HOLD 03/17/2023 03/21/2023
Note: Held By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM Site plan: Legal description ins incorrect. Map Panel should be 0138E 2 car garage homes driveway width max is 36' you have 40' it exceeds please correct
BADMIN COMPLETE 03/17/2023 03/21/2023
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
CONTRACTOR CHANGE ¤20.00 06/03/2024
SW ENG - INSPECTION 20 ¤20.00 06/03/2024
SW ENG - INSPECTION 20 ¤20.00 06/03/2024
SW ENG - INSPECTION 20 ¤20.00 06/03/2024
SW ENG REINSPECTION 20 ¤20.00 06/03/2024
SW ENG REINSPECTION 20 ¤20.00 06/03/2024
SW ENG REINSPECTION 30 ¤30.00 06/03/2024
UTILITY PEP REINSPECTION ¤40.00 06/03/2024
REINSPECTION RESIDENTIAL ¤40.00 06/03/2024
CONNECTION FEES ¤1,166.26 04/17/2023
SEWER CREDIT (¤2,016.00) 04/17/2023
SEWER INSPECTION ¤25.00 04/17/2023
SEWER CAPITAL FACILITY ¤5,344.82 04/17/2023
WATER CAPITAL FACILITY FEE ¤3,923.88 04/17/2023
SITE PLAN 30 ¤30.00 04/17/2023
SW ENG - REVIEW 20 ¤20.00 04/17/2023
SW ENG RES REVIEW 200 ¤200.00 04/17/2023
TRANS IMPACT FEE ADMIN ¤84.36 04/17/2023
TRANS IMPACT FEE ADMIN (¤84.36) 04/17/2023
SW ENG INSPECTION 80 ¤80.00 04/17/2023
SW ENG PRE APRON ¤30.00 04/17/2023
WATER- TURN ON ¤25.00 04/17/2023
ADJUSTMENT 50% (¤570.98) 04/17/2023
ADMINISTRATIVE RESIDENTIAL ¤30.00 04/17/2023
INSPECTION - RESIDENTIAL ¤866.25 04/17/2023
PLAN REVIEW - RESIDENTIAL ¤245.70 04/17/2023
FIRE IMPACT FEE ADMIN ¤25.23 04/17/2023
FIRE IMPACT FEE ADMIN (¤25.23) 04/17/2023
FC IMPACT FEE EMS ¤124.00 04/17/2023
IMPACT FEE FIRE ¤841.04 04/17/2023
FC IMPACT FEE LAW ENFORCEMENT ¤436.00 04/17/2023
FC IMPACT FEE LIBRARY ¤536.00 04/17/2023
IMPACT FEE PARKS ¤3,538.30 04/17/2023
IMPACT FEE SCHOOL ¤10,900.00 04/17/2023
IMPACT FEE TRANSPORTATION ¤2,812.00 04/17/2023
WATER -IRRIGATION INSPECTION ¤25.00 04/17/2023
PARKS IMPACT FEE ADMIN ¤106.15 04/17/2023
PARKS IMPACT FEE ADMIN (¤106.15) 04/17/2023
SURCHARGE FS 533.721 ¤3.64 04/17/2023
SURCHARGE - FS 468.631 ¤5.47 04/17/2023
SW ENG - FOUNDATION SURVEY ¤20.00 04/17/2023
Fees Total Due: ¤0.00 Total Paid: ¤28,871.38