Permit #2023031023

Permit Details

Status: FINAL

Parcel Id: 07-11-31-7037-01580-0150
CONDITIONED SPACE: 739 sqft
OPENED PORCH (WITH ROOF) : 61 sqft
Total Square Footage: 800 sqft
Block: 01580
Subdivision: 2176 - SECTION 37-LAKEVIEW
Job Phone: 904-347-7837
Location Address: 35 LEAVER DR
Type: BA - BUILDING ADDITION
Issue Date: 06/15/2023
NOC: RECORDED
Applicant name: ERIC PAUL PANNONE
Owner: HERNANDEZ CARLOS M & KAROLE Y HERNANDEZ H&W

Address

35 LEAVER DRIVE

PALM COAST, FL 32137

Lot: 0150
Contracted Stated Job Value: ¤125,000.00
Job Description: Addition to rear of home
Type: CN

Contractor

CASTAWAY CONSTRUCTION LLC
Status Location Address State License Number Phone
INACTIVE

30 FERNON LANE

PALM COAST, FL 32137

CBC1266321 (Exp: 08/31/2026) 904-347-7837

Sub Contractors

ANTONIO VINCENZO DAHM
Status Location Address State License Number Phone
ACTIVE

10 RYBAR LANE

PALM COAST, FL 32164

CFC1429951 (Exp: 08/31/2026) 386-237-5692
OLEG BELINSKIY
Status Location Address State License Number Phone
ACTIVE

19 PINE CIRCLE DRIVE19

PALM COAST, FL 32167

CCC1325974 (Exp: 08/31/2026) 386-263-7906
JASON BIANCANIELLO
Status Location Address State License Number Phone
ACTIVE

2434 COUNTY RD 304

BUNNELL, FL 32110

EC13007497 (Exp: 08/31/2026) 386-597-3350
SHAWN R RAMNARINE SINGH
Status Location Address State License Number Phone
INACTIVE

4 SEASIDE CT

PALM COAST, FL 32164

CAC1818766 (Exp: 08/31/2026) 306-302-2179

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 06/18/2024 FINAL APPROVED JSTEWART
Note: 6/13/2024 - PREVIOUS INSPECTION NOTES *** NOTES ADDED BY JSTEWART 6/13/2024 10:08:29 AM *** Please install a carbon Monoxide detector or combination within 10ft max from New bedroom door. R315.1 Carbon monoxide protection.
BLD - BUILDING FINAL 06/13/2024 Disapproved - NO FEE JSTEWART
Note: *** NOTES ADDED BY JSTEWART 6/13/2024 10:08:29 AM *** Please install a carbon Monoxide detector or combination within 10ft max from New bedroom door. R315.1 Carbon monoxide protection.
U -UTILITY RESIDENTIAL FINAL 06/12/2024 FINAL APPROVED BWRIGHT
ROW- FINAL SURVEY/GRADING CERTIFICATION 06/11/2024 APPROVED EMADISON
ROW FIELD SURVEY /GRADING CERTIFICATION 06/11/2024 APPROVED EMADISON
ROW - FINAL INSPECTION 06/11/2024 APPROVED EMADISON
ROW- FINAL SURVEY/GRADING CERTIFICATION 05/23/2024 Disapproved - NO FEE EMADISON
Note: ** 05/23/24 BUILDER STILL NEEDS MORE ELEVATION SHOTS ALONG LEFT SIDE PROPERTY LINE AND RIGHT SIDE ** FFE ELEVATION SHOTS ARE REQUIRED ON ALL ADJACENT PROPERTIES ** ELEVATION SHOTS REQUIRED ACROSS REAR PROPERTY LINE _______________________________________________________________________________________________________________________ 5/3/2024 - PREVIOUS INSPECTION NOTES *** NOTES ADDED BY EMADISON 5/3/2024 8:42:03 AM *** ** 05/03/24 10 FT OFF-SET ELEVATION SHOTS ARE REQUIRED FOR ADJACENT PROPERTIES ** NEED MORE ELEVATION SHOTS ALONG THE LEFT SIDE PROPERTY LINE
ROW- FINAL SURVEY/GRADING CERTIFICATION 05/03/2024 Disapproved - NO FEE EMADISON
Note: *** NOTES ADDED BY EMADISON 5/3/2024 8:42:03 AM *** ** 05/03/24 10 FT OFF-SET ELEVATION SHOTS ARE REQUIRED FOR ADJACENT PROPERTIES ** NEED MORE ELEVATION SHOTS ALONG THE LEFT SIDE PROPERTY LINE
SEWER TIE IN 02/08/2024 APPROVED MGIBSON
INSULATION 01/17/2024 APPROVED FWILLIS
LATH/BRICK/ WATER BARRIER 12/19/2023 APPROVED FWILLIS
Note: New inspection due to canceled inspection Inspector Notes from Inspection 2420 DWV need to be under test at insulation inspection.
LATH/BRICK/ WATER BARRIER 12/18/2023 CANCELLED BY APPLICANT WEB
Note: Inspector Notes from Inspection 2420 DWV need to be under test at insulation inspection.
ALL ROUGH 12/13/2023 APPROVED - AS NOTED JWALKER
Note: DWV need to be under test at insulation inspection.
ROOF VALLEY & METAL 11/30/2023 APPROVED FWILLIS
ROOF SHEATHING / BRACES/TIES/DOWN CELL 11/22/2023 APPROVED FWILLIS
Note: 11/22/23 - ITEMS CORRECTED 11/20/2023 - PREVIOUS INSPECTION NOTES 11/1/2023 - PREVIOUS INSPECTION NOTES NEED TRUSS DETAIL WITH FASTENERS. DETAIL SHOWING MINIMUM LAP OF 2X12 AND NAILING PATTERN. BROKEN DAMAGED TRUSS NEED APPROVED REPAIR FROM ENGINEER. ARE STRAPS COMING OUT OF CMU CORRECT STRAPS. (META OR HETA). INSPECTION STOPPED. 11-20-2023 Approved drawings not on site.
ROOF SHEATHING / BRACES/TIES/DOWN CELL 11/20/2023 Disapproved -FEE REQUIRED AGAETANO
Note: 11/1/2023 - PREVIOUS INSPECTION NOTES NEED TRUSS DETAIL WITH FASTENERS. DETAIL SHOWING MINIMUM LAP OF 2X12 AND NAILING PATTERN. BROKEN DAMAGED TRUSS NEED APPROVED REPAIR FROM ENGINEER. ARE STRAPS COMING OUT OF CMU CORRECT STRAPS. (META OR HETA). INSPECTION STOPPED. 11-20-2023 Approved drawings not on site.
ROOF SHEATHING 11/17/2023 APPROVED FWILLIS
ROOF SHEATHING / BRACES/TIES/DOWN CELL 11/01/2023 Disapproved - NO FEE FWILLIS
Note: NEED TRUSS DETAIL WITH FASTENERS. DETAIL SHOWING MINIMUM LAP OF 2X12 AND NAILING PATTERN. BROKEN DAMAGED TRUSS NEED APPROVED REPAIR FROM ENGINEER. ARE STRAPS COMING OUT OF CMU CORRECT STRAPS. (META OR HETA). INSPECTION STOPPED.
TIE BEAM / LINTEL 10/19/2023 APPROVED FWILLIS
MONOLITHIC SLAB 10/05/2023 APPROVED FWILLIS
Note: 10/4/2023 - PREVIOUS INSPECTION NOTES TWO (2) PIECES OF REBAR MISSING ON LEFT SIDE.
MONOLITHIC SLAB 10/04/2023 Disapproved - NO FEE FWILLIS
Note: TWO (2) PIECES OF REBAR MISSING ON LEFT SIDE.
PLUMBING 1ST ROUGH UNDERGROUND 09/15/2023 APPROVED MGIBSON

Review History

Department Status Date In Date Out
BADMIN INFORMATION 04/23/2024 04/23/2024
Note: Marked INFORMATION By: NICOLE DIMATTINA - - NDIMATTINA@PALMCOASTGOV.COM NOC is expired, we can't accept the final survey until we get a valid NOC.
BADMIN INFORMATION 09/01/2023 09/01/2023
Note: Marked INFORMATION By: BARBIE BEMBRY - (386)986-3780 - BUILDINGDIVISION@PALMCOASTGOV.COM Documents/Files named incorrectly o Please rename your files in accordance with the naming convention outlined in our ‘document requirements’ located on the permit portal page http://docs.palmcoastgov.com/departments/building/online/document-requirements.pdf o It is important that all submittals follow the guidelines for efficient plan review and record retention accuracy. o You may add to your file name AFTER the above naming convention has been met. Examples Document type: Plans File name : Plans Document type: Foundation Survey File name: Foundation Survey Document type: Manufactures Specifications File Name: Pool Alarm Document type: Manufactures Specifications File Name: Generator
BLD COMPLETE 09/01/2023 09/11/2023
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
ELEC COMPLETE 09/01/2023 09/11/2023
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
BLD COMPLETE 06/02/2023 06/05/2023
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
MECH COMPLETE 05/25/2023 05/30/2023
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
BLD HOLD 05/25/2023 05/31/2023
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM 1. Identify glazing in window adjacent to new exterior door from pool room as safety glazing. R308.4.2 (REPEAT COMMENT) 2. Provide type of shower enclosure finishes. If tile then provide tile backer board specs per Secton R702.4.2 and Table R702.4.2. (REPEAT COMMENT)
MECH HOLD 05/12/2023 05/18/2023
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM 3. Energy Calcs need to be signed by the builder below the preparer (Repeat comment)
BLD HOLD 05/12/2023 05/18/2023
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM New comment: Plans need to have a verifiable seal..Unable to verify. F.S. 471.025 1. OK 2. OK Plan Sheet 1 of 2 3. ok 4. ok 5. Provide note indicating smoke detector in proposed addition to be interconnected with other smoke detectors in home. R314.4 (REPEAT COMMENT) 6. ok 7. ok 8. ok 9. Identify glazing in window adjacent to new exterior door from pool room as safety glazing. R308.4.2 (REPEAT COMMENT) 10. OK 11. Ok 12. Ok 13. Provide type of shower enclosure finishes. If tile then provide tile backer board specs per Secton R702.4.2 and Table R702.4.2. (REPEAT COMMENT) 14. Ok Plan Sheet 2 of 2 15. Remove Typical Valley Framing Detail from plans - there is no valley framing for this roof. 107.2.1 (REPEAT COMMENT) 16. Detail 1/F Correct reference to proposed roofing underlayment. It is not a vapor barrier, it is underlayment. One layer of 30 pound felt is not allowed. Ensure underlyament type matches Roofing Worksheet. R905.1.1.1 (REPEAT COMMENT) 17. Detail 1/F indicates engineered roof trusses. This reference conflicts with Roof Framing Plan at lower right corner of plans - please reconcile. If roof framing is proposed using conventional framing and lumber, the roof plan needs several revisions and is lacking required information and details. Roof framing not reviewed, plan is deficient and cannot be reviewed as submitted. 107.2.1 (REPEAT COMMENT) 18. ok
ZON COMPLETE 05/08/2023 05/08/2023
Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM
MECH HOLD 05/04/2023 05/05/2023
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM 1. Provide detail on electrical plans showing service outlet and light in attic near AHU per NEC 210.63 and NEC 110.26D 2. Provide detail on plans showing trusses are designed to handle additional load and any required framing details. 3. Energy Calcs need to be signed by the builder below the preparer
ZON HOLD 05/04/2023 05/04/2023
Note: Held By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM Please submit original Single Family Dwelling Affidavit.
BLD HOLD 05/04/2023 05/10/2023
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM New comment: Plans need to have a verifiable seal..Unable to verify. F.S. 471.025 1. OK 2. OK Plan Sheet 1 of 2 3. ok 4. ok 5. Provide note indicating smoke detector in proposed addition to be interconnected with other smoke detectors in home. R314.4 (REPEAT COMMENT) 6. ok 7. ok 8. ok 9. Identify glazing in window adjacent to new exterior door from pool room as safety glazing. R308.4.2 (REPEAT COMMENT) 10. OK 11. Ok 12. Provide detail showing elevation of addition floor in relation to existing home. Floor level at doors to be within 1 inch of top of door thresholds - no step down. R311.3.1 (REPEAT COMMENT) 13. Provide type of shower enclosure finishes. If tile then provide tile backer board specs per Secton R702.4.2 and Table R702.4.2. (REPEAT COMMENT) 14. Ok Plan Sheet 2 of 2 15. Remove Typical Valley Framing Detail from plans - there is no valley framing for this roof. 107.2.1 (REPEAT COMMENT) 16. Detail 1/F Correct reference to proposed roofing underlayment. It is not a vapor barrier, it is underlayment. One layer of 30 pound felt is not allowed. Ensure underlyament type matches Roofing Worksheet. R905.1.1.1 (REPEAT COMMENT) 17. Detail 1/F indicates engineered roof trusses. This reference conflicts with Roof Framing Plan at lower right corner of plans - please reconcile. If roof framing is proposed using conventional framing and lumber, the roof plan needs several revisions and is lacking required information and details. Roof framing not reviewed, plan is deficient and cannot be reviewed as submitted. 107.2.1 (REPEAT COMMENT) 18. ok
BADMIN INFORMATION 04/25/2023 04/25/2023
Note: Marked INFORMATION By: BARBIE BEMBRY - (386)986-3780 - BUILDINGDIVISION@PALMCOASTGOV.COM The seal on the plans cannot be verified, the seal has been broken.
BLD HOLD 03/17/2023 03/24/2023
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM All Comments from FBC Residential 2020 7Th edition 1. Provide completed City of Palm Coast roofing worksheet. 107.2.1 2. Provide product approval number for soffits, lintels and mullions on product approval worksheet. 107.2.1 Plan Sheet 1 of 2 3. Identify "new room" by proper name / intended use. New room is insufficinet. Is it a living room? Bedroom? Office? If room is to be a bedroom show location of smoke detector. Show smoke detector outside of bedroom door in existing house. R314..3 4. If new room is a bedroom, indicate window to be emergency escape window. R310.1 5. Provide note indicating smoke detector in proposed addition to be interconnected with other smoke detectors in home. R314.4 6. If new room is a bedroom, provide carbon monoxide alarm outside, but within 10 feet of bedroom. R315.1 7. Provide note indicating carbon monoxide alarms are required outside of, but within 10 feet of all existing bedrooms. R315.1 8. Identify glazing in existing windows on both sides of door opening from existing house into "new room" as safety glazing. R308.4.2 9. Identify glazing in window adjacent to new exterior door from pool room as safety glazing. R308.4.2 10. Provide attic ventilation calculations for proosed addition. Show location of requried attic vents and attic access. R806 11. Provide corrected rear elevation. Elevation view is reverse from new addition floor plan. 107.2.1 12. Provide detail showing elevation of addition floor in relation to existing home. Floor level at doors to be within 1 inch of top of door thresholds - no step down. R311.3.1 13. Provide type of shower enclosure finishes. If tile then provide tile backer board specs per Secton R702.4.2 and Table R702.4.2. 14. Where is detail for the new fixed window in existing living room? Please reference and label the detail. 107.2.1 Plan Sheet 2 of 2 15. Remove Typical Valley Framing Detail from plans - there is no valley framing for this roof. 107.2.1 16. Detail 1/F Correct reference to proposed roofing underlayment. It is not a vapor barrier, it is underlayment. One layer of 30 pound felt is not allowed. Ensure underlyament type matches Roofing Worksheet. R905.1.1.1 17. Detail 1/F indicates engineered roof trusses. This reference conflicts with Roof Framing Plan at lower right corner of plans - please reconcile. If roof framing is proposed using conventional framing and lumber, the roof plan needs several revisions and is lacking required information and details. Roof framing not reviewed, plan is deficient and cannot be reviewed as submitted. 107.2.1 18. Provide detail for connection of additon foundation / monolithic slab to existing house foundation. 107.2.1
ELEC COMPLETE 03/17/2023 03/22/2023
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
GAS CANCEL 03/17/2023 03/20/2023
MECH HOLD 03/17/2023 03/20/2023
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Provide Energy Calcs, heatload and duct layout
PLUM COMPLETE 03/17/2023 03/24/2023
Note: Released By: PATRICK BUCKLEY - (386)986-3786 - PBUCKLEY@PALMCOASTGOV.COM
SW1 COMPLETE 03/17/2023 03/22/2023
Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM
ZON HOLD 03/17/2023 03/20/2023
Note: Held By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM Please submit Single Family Dwelling Affidavit. This Affidavit must be signed by all persons on deed to property and all owners signatures must be notarized. Please submit electronic copy of this document for staff review and once it is approved, we will require the original.

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION RESIDENTIAL ¤40.00 06/09/2024
RECORDING FEE REIMBURSE DOC ¤10.00 06/15/2023
SURCHARGE FS 533.721 ¤2.36 06/15/2023
SURCHARGE - FS 468.631 ¤3.54 06/15/2023
SW ENG - INSPECTION 20 ¤20.00 06/15/2023
SW ENG - REVIEW 20 ¤20.00 06/15/2023
SITE PLAN 30 ¤30.00 06/15/2023
ADJUSTMENT 50% (¤235.63) 06/15/2023
ADMINISTRATIVE RESIDENTIAL ¤30.00 06/15/2023
INSPECTION - RESIDENTIAL ¤343.75 06/15/2023
PLAN REVIEW - RESIDENTIAL ¤97.50 06/15/2023
Fees Total Due: ¤0.00 Total Paid: ¤361.52