Permit #2023031529

Permit Details

Status: FINAL

Parcel Id: 07-11-31-7012-00180-0320
ENCLOSE EXISTING PORCH TO LIVING : 198 sqft
Total Square Footage: 198 sqft
Block: 00180
Subdivision: 2187 - SECTION 12-BELLE TERRE
Job Phone: 386-597-9271
Location Address: 2 BARKLEY LN
Type: BA - BUILDING ADDITION
Issue Date: 04/24/2023
NOC: Unknown
Applicant name: GARY W MCCAIN
Owner: GIRGUS SHERRY A

Address

2 BARKLEY LANE

PALM COAST, FL 32137

Lot: 0320
Contracted Stated Job Value: ¤20,000.00
Job Description: ADDITION TO REAR OF HOME
Type: CN

Contractor

MCCAIN CONSTRUCTION LLC
Status Location Address State License Number Phone
ACTIVE

15 WEIDNER PLACE

PALM COAST, FL 32164

CBC1261573 (Exp: 08/31/2026) 386-447-0035

Sub Contractors

GARY LLOYD SHEFFIELD
Status Location Address State License Number Phone
ACTIVE

48 EAGLE LAKES DRIVE

FLAGLER BEACH, FL 32136

CAC048127 (Exp: 08/31/2026) 386-597-3280

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 08/11/2023 FINAL APPROVED JSTEWART
Note: 8/8/2023 - PREVIOUS INSPECTION NOTES 8/8/23- Bathroom window needs to be tempered. R308.4 Hazardous locations.....R308.4.5 Glazing and wet surfaces. Missing (3) anchors bedroom window right lower side.
BLD - BUILDING FINAL 08/08/2023 Disapproved - NO FEE JSTEWART
Note: 8/8/23- Bathroom window needs to be tempered. R308.4 Hazardous locations.....R308.4.5 Glazing and wet surfaces. Missing (3) anchors bedroom window right lower side.
ROW- FINAL SURVEY/GRADING CERTIFICATION 07/25/2023 APPROVED GBERTOLA
Note: CORRECTION WERE MADE At the time of the inspection all minimum city requirements were met. It is the builders responsibility to ensure that nothing changes after this Inspection is approved.
ROW FIELD SURVEY /GRADING CERTIFICATION 07/25/2023 APPROVED GBERTOLA
Note: At the time of the inspection all minimum city requirements were met. It is the builders responsibility to ensure that nothing changes after this Inspection is approved.
ROW - FINAL INSPECTION 07/25/2023 APPROVED GBERTOLA
Note: At the time of the inspection all minimum city requirements were met. It is the builders responsibility to ensure that nothing changes after this Inspection is approved.
TIE BEAM / LINTEL 07/06/2023 APPROVED FWILLIS
ROW- PRE-APRON (PRE-POUR) 07/05/2023 CANCELLED BY APPLICANT GBERTOLA
Note: 7/5/23= BUILDER CALL ME AND EXPLAIN TO ME, WAS THE WRONG INSPECTION . INSPECTION FOR PRE POUR IS CANCELLED BY APPLICANT
LATH/BRICK/ WATER BARRIER 06/01/2023 APPROVED JSTEWART
ROOF SHEATHING / BRACES/TIES/DOWN CELL 05/22/2023 CANCELLED BY APPLICANT WEB
Note: Inspector Notes from Inspection 2420 5/18/2023--Multiple locations of windows missing anchors, Please install and will check at Insulation.
ROOF SHEATHING / BRACES/TIES/DOWN CELL 05/22/2023 APPROVED JSTEWART
Note: New inspection due to canceled inspection Inspector Notes from Inspection 2420 5/18/2023--Multiple locations of windows missing anchors, Please install and will check at Insulation.
INSULATION 05/22/2023 APPROVED JSTEWART
ALL ROUGH 05/18/2023 APPROVED - AS NOTED JSTEWART
Note: 5/18/2023--Multiple locations of windows missing anchors, Please install and will check at Insulation.
ROOF SHEATHING / BRACES/TIES/DOWN CELL 05/18/2023 PARTIALLY APPROVED JSTEWART
Note: 5/18/2023--Angle steal at Lintel is installed on the Addition side, Once existing exterior wall is demoed, inspect 2nd Angle steal support. Please add Tapcons in TP to existing bond beam per plans will check at insulation.
MONOLITHIC SLAB 05/01/2023 APPROVED JSTEWART

Review History

Department Status Date In Date Out
BLD COMPLETE 04/21/2023 04/24/2023
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ELEC COMPLETE 04/11/2023 04/12/2023
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
MECH COMPLETE 04/11/2023 04/12/2023
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
BLD HOLD 04/11/2023 04/18/2023
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM 1. Exterior wall section to be corrected to show stucco is a three coat system. R703.7.2. (Not Addressed) 2. Exterior wall section to be corrected to include a water resistive barrier that complies with R703.7.3 - must be equivalent to two layers of Grade D paper. To my knowledge standard Tyvek house wrap doesn't meet this standard and must be stucco wrap or similar. (Not Addressed) 3. Ok 4. Ok 5. Ok 6. Ok 7. Floor plan to be corrected to reference the existing home to be provided with carbon monoxide alarms. R315.1. Indicate carbon monoxide alarms required within 10 feet of each sleeping room / bedroom entrances. (Not Addressed) 8. Floor plan to be corrected to refernce windows adjacent to operable panels of sliding door to be tempered glass. R308.4.2. (Not Addressed)
PLUM CANCEL 04/11/2023 04/18/2023
BLD HOLD 03/28/2023 04/03/2023
Note: Held By: PATRICK BUCKLEY - (386)986-3786 - PBUCKLEY@PALMCOASTGOV.COM Exterior wall section to be corrected to show stucco is a three coat system. R703.7.2. Exterior wall section to be corrected to include a water resistive barrier that complies with R703.7.3 - must be equivalent to two layers of Grade D paper. To my knowledge standard Tyvek house wrap doesn't meet this standard and must be stucco wrap or similar. Exterior wall section to be corrected to show weep screed and ASTM standard. R703.7.2.1. Exterior wall section to be corrected to show lumber species in addition to lumber grade for wall stud framing. R602.1.1, R602.2, R602.3.(5). Exterior wall section to be corrected to include a flashing detail (type and materials) above all new door and window rough openings. R703.4. Floor plan to be corrected to indicate room name (e.g. family room, bedroom, etc.) Chapter 3 - need to know use of room to determine appliable code provisions. If room is to be used as a sleeping room / bedroom, provide location of smoke alarm inside room and smoke alarm and carbon monoxide alarm outside room. R314, R315. Floor plan to be corrected to reference the existing home to be provided with carbon monoxide alarms. R315.1. Indicate carbon monoxide alarms required within 10 feet of each sleeping room / bedroom entrances. Floor plan to be corrected to refernce windows adjacent to operable panels of sliding door to be tempered glass. R308.4.2.
ELEC HOLD 03/28/2023 03/29/2023
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM List electrical sub contractor.
GAS CANCEL 03/28/2023 03/29/2023
MECH HOLD 03/28/2023 03/29/2023
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Provide Energy Calcs, heatload and duct layout
PLUM HOLD 03/28/2023 04/03/2023
Note: Held By: PATRICK BUCKLEY - (386)986-3786 - PBUCKLEY@PALMCOASTGOV.COM See Building Plan Review comments. Need identy room use for a complete plan review. If room is identifed as room that does not include plumbing, then this Plumbing Reveiw will be removed.
SW1 COMPLETE 03/28/2023 04/04/2023
Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM
ZON COMPLETE 03/28/2023 03/28/2023
Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
ADJUSTMENT 50% (¤77.50) 04/24/2023
ADMINISTRATIVE RESIDENTIAL ¤30.00 04/24/2023
INSPECTION - RESIDENTIAL ¤60.00 04/24/2023
PLAN REVIEW - RESIDENTIAL ¤65.00 04/24/2023
SURCHARGE FS 533.721 ¤2.00 04/24/2023
SURCHARGE - FS 468.631 ¤2.00 04/24/2023
SW ENG - INSPECTION 20 ¤20.00 04/24/2023
SW ENG - REVIEW 20 ¤20.00 04/24/2023
SITE PLAN 30 ¤30.00 04/24/2023
Fees Total Due: ¤0.00 Total Paid: ¤151.50