I want to search for...

Permit #2023040893

Permit Details

Status: FINAL

Parcel Id: 07-11-31-7032-00590-0100
Block: 00590
Subdivision: 2155 - SECTION 32-ROYAL PALMS
Job Phone: 386-236-9610
Location Address: 8 ROCKNE LN
Type: PO - POOL
Issue Date: 05/10/2023
NOC: RECORDED
Applicant name: SAMANTHA JESSICA ALEXANDER
Owner: DENNING MARLO F & MICHAEL W W&H

Address

8 ROCKNE LN

PALM COAST, FL 32164

Lot: 0100
Contracted Stated Job Value: ¤77,000.00
Job Description: SWIMMING POOL (EXISTING FENCE)
Type: CN

Contractor

AGUA POOLS AND SPA INC
Status Location Address State License Number Phone
ACTIVE

3438 LONGLEAF ROAD

,

CPC1459907 (Exp: 08/31/2026) 386-492-6910

Sub Contractors

CHARLES K DAVIS
Status Location Address State License Number Phone
INACTIVE

1410 RIDGEWOOD AVE

HOLLY HILL, FL 32117

EC13011552 (Exp: 08/31/2026) 386-236-9610

Inspection History

Type Request Date Result Inspector
POOL FINAL 04/17/2024 FINAL APPROVED AGAETANO
Note: 4/16/2024 - PREVIOUS INSPECTION NOTES 2/8/2024 - PREVIOUS INSPECTION NOTES 1. Vacuum guage not installed at the pool pump for TDH test. 2. Fence barrier is to be a minimum of 48" off of the grade.. 3. Clearance under the left side gate/ barrier can be no more that 2" from the grade to the bottom of the gate. 4. The sreen door latch at the lania is to be a minimum of 54" to the latch. 5. Interior alarm for the pool guard type alarm not installed. 04-16-2024 Above issue has not been resolved. Clearance under the left side gate/ barrier can be no more that 2" from the grade to the bottom of the gate. Sod needs to be placed under gate.
POOL FINAL 04/16/2024 Disapproved - NO FEE AGAETANO
Note: 2/8/2024 - PREVIOUS INSPECTION NOTES 1. Vacuum guage not installed at the pool pump for TDH test. 2. Fence barrier is to be a minimum of 48" off of the grade.. 3. Clearance under the left side gate/ barrier can be no more that 2" from the grade to the bottom of the gate. 4. The sreen door latch at the lania is to be a minimum of 54" to the latch. 5. Interior alarm for the pool guard type alarm not installed. 04-16-2024 Above issue has not been resolved. Clearance under the left side gate/ barrier can be no more that 2" from the grade to the bottom of the gate. Sod needs to be placed under gate. Piling up dirt into a mound is not considered the grade.
POOL FINAL 02/08/2024 Disapproved - NO FEE JWALKER
Note: 1. Vacuum guage not installed at the pool pump for TDH test. 2. Fence barrier is to be a minimum of 48" off of the grade..From the side facing away from the pool. 3. Clearance under the left side gate/ barrier can be no more that 2" from the grade to the bottom of the gate. 4. The sreen door latch at the lania is to be a minimum of 54" to the latch. 5. Interior alarm for the pool guard type alarm not installed.
POOL FINAL 02/07/2024 CANCELLED BY APPLICANT JWALKER
U -UTILITY RESIDENTIAL FINAL 02/06/2024 FINAL APPROVED LFITZGERALD
ROW FIELD SURVEY /GRADING CERTIFICATION 02/05/2024 APPROVED PFLANAGAN
Note: MEET WITH MIKE AND HOMEOWNER AND HOMEOWNER THEY ARE NOT HAVING ANY STANDING WATER IN THE LOW AREAS AND WITH LAST NIGHT RAIN NO WATER TODAY ---------------------------------------------------------------------------------- 1/26/2024 - PREVIOUS INSPECTION NOTES THE FIELD INSPECTION SHOWS WATER WILL SIT IN BACK LEFT OF BACKYARD AND ALL WATER IS IMPACTING THE LOT BEHIND THIS LOT. NEED TO FIX ALL AREAS
ROW - FINAL INSPECTION 02/05/2024 APPROVED PFLANAGAN
Note: At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved.
ROW- PROJECT STATUS 02/05/2024 APPROVED PFLANAGAN
Note: MEETING WITH MIKE FOR DRAINAGE OF BACK YARD 1PM
ROW- FINAL SURVEY/GRADING CERTIFICATION 01/26/2024 APPROVED PFLANAGAN
Note: SURVEY SHOWS THE WATER WILL NOT IMPACT THE ADJACENT LOTS NOW ------------------------------------------------------------------------------ 11/27/2023 - PREVIOUS INSPECTION NOTES THE FINAL SURVEY DOESN'T SHOW LOW AREAS IN THE BACK RIGHT BY THE SHED AND LEFT BACK CORNER OF THE LOT NEED TO FIX GRADING SO WATER WILL NOT SIT IN THOSE AREAS AND DON'T IMPACT THE ADJACENT LOT BRHIND IT. WHEN BUILDING A POOL ALL GRADING NEEDS TO BE UP TO ALL CITY'S STANDARDS FOR THE GRADING.
ROW FIELD SURVEY /GRADING CERTIFICATION 01/26/2024 Disapproved - NO FEE PFLANAGAN
Note: THE FIELD INSPECTION SHOWS WATER WILL SIT IN BACK LEFT OF BACKYARD AND ALL WATER IS IMPACTING THE LOT BEHIND THIS LOT. NEED TO FIX ALL AREAS
ROW- FINAL SURVEY/GRADING CERTIFICATION 11/27/2023 Disapproved - NO FEE PFLANAGAN
Note: THE FINAL SURVEY DOESN'T SHOW LOW AREAS IN THE BACK RIGHT BY THE SHED AND LEFT BACK CORNER OF THE LOT NEED TO FIX GRADING SO WATER WILL NOT SIT IN THOSE AREAS AND DON'T IMPACT THE ADJACENT LOT BRHIND IT. WHEN BUILDING A POOL ALL GRADING NEEDS TO BE UP TO ALL CITY'S STANDARDS FOR THE GRADING.
ELECTRIC AND ALARM 08/24/2023 APPROVED JWALKER
POOL DECK 08/02/2023 APPROVED MKRASKI
POOL DECK 08/01/2023 Disapproved - NO FEE JWALKER
Note: Slab area needs to be tamped down
POOL DECK 07/31/2023 CANCELLED BY APPLICANT WEB
STEEL AND GROUND 07/06/2023 APPROVED JWALKER
Note: 7/5/2023 - PREVIOUS INSPECTION NOTES 1. Clean all soil wash outs rebar is to have 3" ground clearance 2. Plumbing line pressure gauge at the spa area is not operating when valve was open gauged did not move. Line not filled.
STEEL AND GROUND 07/05/2023 Disapproved - NO FEE JWALKER
Note: 1. Clean all soil wash outs rebar is to have 3" ground clearance 2. Plumbing line pressure gauge at the spa area is not operating when valve was open gauged did not move. Line not filled.

Review History

Department Status Date In Date Out
BLD COMPLETE 05/31/2023 06/01/2023
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
SW1 COMPLETE 05/31/2023 06/08/2023
Note: Released By: ROBERT GROSS - (386)986-4769 - RGROSS@PALMCOASTGOV.COM
ZON COMPLETE 05/31/2023 05/31/2023
Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM
SW1 COMPLETE 05/04/2023 05/09/2023
Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM
SW1 HOLD 04/27/2023 05/04/2023
Note: Held By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM CAN NOT DRAIN WATER TO THE BACK ALL DRAINAGE NEED TO GO FROM BACK TO THE FRONT ROAD SIDE SWALE
ZON COMPLETE 04/27/2023 04/27/2023
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
BLD COMPLETE 04/18/2023 04/20/2023
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ELEC COMPLETE 04/18/2023 04/20/2023
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
MECH COMPLETE 04/18/2023 04/19/2023
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
SW1 HOLD 04/18/2023 04/25/2023
Note: Held By: FRANK SLADISH - - FSLADISH@PALMCOASTGOV.COM Lot drainage features and patterns must be clearly depicted and include flow arrows.
ZON COMPLETE 04/18/2023 04/19/2023
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
SW ENG REINSPECTION 20 ¤20.00 02/06/2024
SW ENG - REVIEW 20 ¤20.00 05/10/2023
SITE PLAN 30 ¤30.00 05/10/2023
ADJUSTMENT 50% (¤127.50) 05/10/2023
ADMINISTRATIVE RESIDENTIAL ¤30.00 05/10/2023
INSPECTION- POOL ¤160.00 05/10/2023
PLAN REVIEW - RESIDENTIAL ¤65.00 05/10/2023
SURCHARGE FS 533.721 ¤2.00 05/10/2023
SURCHARGE - FS 468.631 ¤2.00 05/10/2023
SW ENG INSPECTION 40 ¤40.00 05/10/2023
Fees Total Due: ¤0.00 Total Paid: ¤241.50