I want to search for...
Permit #2023041101
Permit Details
Status: FINAL
| Parcel Id: 07-11-31-7031-00300-0100 |
| Block: 00300 |
| Subdivision: 2166 - SECTION 31-ROYAL PALMS |
| Job Phone: 386-212-2958 |
| Location Address: 34 RICHELIEU LN |
| Type: PO - POOL |
| Issue Date: 05/22/2023 |
| NOC: RECORDED |
| Applicant name: COBY KYLE MOORE |
| Owner: VERDUGO THOMAS & NANCY H&W |
|
Address 34 RICHELIEU LANE PALM COAST, FL 32164 |
| Lot: 0100 |
| Contracted Stated Job Value: ¤60,000.00 |
| Job Description: swimming pool with deck- fence for outer safety |
| Type: CN |
Contractor
CM DESIGNS INC.
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
1050 ROBERTS STREET ORMOND BEACH, FL 32174 |
CPC1456991 (Exp: 08/31/2026) | (386)615-7425 | 386-676-2963 |
Sub Contractors
GREGORY ALAN WARD
| Status | Location Address | State License Number | Phone |
| INACTIVE |
P.O. BOX 731453 ORMOND BEACH, FL 32174 |
EC13005000 (Exp: 08/31/2026) | 386-566-7248 |
Inspection History
| Type | Request Date | Result | Inspector |
| POOL FINAL | 01/05/2024 | FINAL APPROVED | JWALKER |
| Note: 1/4/2024 - PREVIOUS INSPECTION NOTES 1. Permit needs to be onsite along with TDH calculations. 2. The access gates 1 single gate right side of the house, 1 double gate right side, and double gate located right side of the fence. These gates are not conforming to RBC- R4501.17.1.8 Access gates, when provided, shall be self-closing and shall comply with the requirements of Sections R4501.17.1.1 through R4501.17.1.7 and shall be equipped with a self-latching locking device located on the pool side of the gate. Where the device release is located no less than 54 inches (1372 mm) from the bottom of the gate, the device release mechanism may be located on either side of the gate and so placed that it cannot be reached by a young child over the top or through any opening or gap from the outside. Gates that provide access to the swimming pool must open outward away from the pool. The gates and barrier shall have no opening greater than 1/2 inch (12.7 mm) within 18 inches (457 mm) of the release mechanism. | |||
| POOL FINAL | 01/04/2024 | Disapproved -FEE REQUIRED | JWALKER |
| Note: 1. Permit needs to be onsite along with TDH calculations. 2. The access gates 1 single gate right side of the house, 1 double gate right side, and double gate located right side of the fence. These gates are not conforming to RBC- R4501.17.1.8 Access gates, when provided, shall be self-closing and shall comply with the requirements of Sections R4501.17.1.1 through R4501.17.1.7 and shall be equipped with a self-latching locking device located on the pool side of the gate. Where the device release is located no less than 54 inches (1372 mm) from the bottom of the gate, the device release mechanism may be located on either side of the gate and so placed that it cannot be reached by a young child over the top or through any opening or gap from the outside. Gates that provide access to the swimming pool must open outward away from the pool. The gates and barrier shall have no opening greater than 1/2 inch (12.7 mm) within 18 inches (457 mm) of the release mechanism. | |||
| U -UTILITY RESIDENTIAL FINAL | 01/03/2024 | FINAL APPROVED | LFITZGERALD |
| ROW FIELD SURVEY /GRADING CERTIFICATION | 01/02/2024 | APPROVED | FSLADISH |
| Note: 1/2/24 EVERYTHING LOOKED GOOD AT THE TIME OF THIS INSPECTION. At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved. | |||
| ROW - FINAL INSPECTION | 01/02/2024 | APPROVED | FSLADISH |
| Note: 1/2/24 SWALE IS GOOD. 1/2/24 EVERYTHING LOOKED GOOD AT THE TIME OF THIS INSPECTION. At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 12/26/2023 | APPROVED | FSLADISH |
| Note: 12/21/2023 - PREVIOUS INSPECTION NOTES 12/21/23 THE PROPERTY HAS A PRIVACY FENCE. KNOCKED AND RANG BELL (NO ANSWER), NEED SOMEONE HOME TO GRANT SAFE ACCESS TO BACK YARD FOR INSPECTION FBC 110.1 YOU MAY LEAVE A NOTE AT FRONT DOOR ACKNOWLEDGING IT IS SAFE TO ENTER THROUGH GATE. THERE SHALL BE NO DOGS OR ANIMALS IN YARD FOR INSPECTORS SAFETY. | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 12/21/2023 | Disapproved - NO FEE | TPOLACEK |
| Note: 12/21/23 THE PROPERTY HAS A PRIVACY FENCE. KNOCKED AND RANG BELL (NO ANSWER), NEED SOMEONE HOME TO GRANT SAFE ACCESS TO BACK YARD FOR INSPECTION FBC 110.1 YOU MAY LEAVE A NOTE AT FRONT DOOR ACKNOWLEDGING IT IS SAFE TO ENTER THROUGH GATE. THERE SHALL BE NO DOGS OR ANIMALS IN YARD FOR INSPECTORS SAFETY. | |||
| ELECTRIC AND ALARM | 09/22/2023 | APPROVED - AS NOTED | JWALKER |
| Note: 9/22/23 The pool heater will need to fully bear on the concrete pad. Please have corrected by final. 9/19/2023 - PREVIOUS INSPECTION NOTES 1. Electrical subpanel has not been bonded. 2. Protective conduit for the wiring has not been glued / sealed to prevent water intrusion. 3. Note the pool heater will need to be anchored to the pad in 4 spots it the unit has not been set on the pad correctly and in hanging over on the right side. | |||
| ELECTRIC AND ALARM | 09/19/2023 | Disapproved - NO FEE | JWALKER |
| Note: 1. Electrical subpanel has not been bonded. 2. Protective conduit for the wiring has not been glued / sealed to prevent water intrusion. 3. Note the pool heater will need to be anchored to the pad in 4 spots it the unit has not been set on the pad correctly and in hanging over on the right side. | |||
| POOL DECK | 08/03/2023 | APPROVED | JWALKER |
| STEEL AND GROUND | 07/07/2023 | APPROVED | JWALKER |
| Note: 7/5/2023 - PREVIOUS INSPECTION NOTES 1. Remove roots from bottom of pool 3 locations. 2, Rebar is to have 3" ground clearance. Check all. 3. Plumbing lines are not under test. The deep end pressure guage and valve need to be accessible to open valve and visual inspect the guage. Please Lower the pressure guage and valve. | |||
| STEEL AND GROUND | 07/05/2023 | Disapproved - NO FEE | JWALKER |
| Note: 1. Remove roots from bottom of pool 3 locations. 2, Rebar is to have 3" ground clearance. Check all. 3. Plumbing lines are not under test. The deep end pressure guage and valve need to be accessible to open valve and visual inspect the guage. Please Lower the pressure guage and valve. |
Review History
| Department | Status | Date In | Date Out |
| ZON | COMPLETE | 05/18/2023 | 05/19/2023 |
| Note: Released By: KATIE TAING - (386)986-3751 - KTAING@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 05/18/2023 | 05/22/2023 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ZON | HOLD | 05/10/2023 | 05/11/2023 |
| Note: Held By: KATIE TAING - (386)986-3751 - KTAING@PALMCOASTGOV.COM Repeat Comments: 1. Please provide ALL deck dimensions on the SITE plan to match the pool plan. 2. Pool deck must meet minimum rear setback of 10ft.. 3. Please show fence location and descriptions ON the SITE plan. | |||
| BLD | COMPLETE | 05/10/2023 | 05/11/2023 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 05/10/2023 | 05/15/2023 |
| Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM | |||
| BLD | HOLD | 04/21/2023 | 04/25/2023 |
| Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM Provide detail or note on plans showing existing fence complies with R4501.17.1.8. Show door swing and latch height. | |||
| ELEC | COMPLETE | 04/21/2023 | 04/25/2023 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 04/21/2023 | 04/24/2023 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| SW1 | HOLD | 04/21/2023 | 04/28/2023 |
| Note: Held By: GABRIEL BERTOLA - (386)986-7660 - GBERTOLA@PALMCOASTGOV.COM YOU ARROW Showing WATER IS GOING TO THE BACK AND FRONT. You can not put any water in the home owner in the back The subject lots drainage must not negatively impact any adjacent property. (B) i need flow arrows on the side of the house | |||
| ZON | HOLD | 04/21/2023 | 04/21/2023 |
| Note: Held By: KATIE TAING - (386)986-3751 - KTAING@PALMCOASTGOV.COM 1. Please provide ALL deck dimensions on the site plan to match the pool plan. 2. Pool deck must meet minimum rear setback of 10ft.. 3. Please show fence location on the site plan. |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION RESIDENTIAL | ¤40.00 | 01/04/2024 |
| SURCHARGE FS 533.721 | ¤2.00 | 05/22/2023 |
| SURCHARGE - FS 468.631 | ¤2.00 | 05/22/2023 |
| SW ENG INSPECTION 40 | ¤40.00 | 05/22/2023 |
| SW ENG - REVIEW 20 | ¤20.00 | 05/22/2023 |
| SITE PLAN 30 | ¤30.00 | 05/22/2023 |
| ADJUSTMENT 50% | (¤127.50) | 05/22/2023 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 05/22/2023 |
| INSPECTION- POOL | ¤160.00 | 05/22/2023 |
| PLAN REVIEW - RESIDENTIAL | ¤65.00 | 05/22/2023 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤261.50 |