I want to search for...
Permit #2023041152
Permit Details
Status: CANCEL
| Parcel Id: 07-11-31-7014-00070-1910 |
| Block: 00070 |
| Subdivision: 2202 - SECTION 14-COUNTRY CLUB COVE |
| Job Phone: 386-338-1859 |
| Location Address: 7 CLEVELAND CT |
| Type: PA - PATIO/SLAB (STRUCTURAL) |
| NOC: RECORDED |
| Applicant name: SOPHAN KES |
| Owner: CONNOLLY JULIA & WILLIAM W&H |
|
Address 7 CLEVELAND COURT PALM COAST, FL 32137 |
| Lot: 1910 |
| Contracted Stated Job Value: ¤7,500.00 |
| Job Description: BACK PATIO W/RETAINING WALL |
| Type: CN |
Contractor
KES CONSTRUCTION, INC
| Status | Location Address | State License Number |
| ACTIVE |
42 OAKLEAF WAY PALM COAST, FL 32137 |
CBC1264797 (Exp: 08/31/2026) |
Inspection History
| Type | Request Date | Result | Inspector |
| MONOLITHIC SLAB | |||
| FOOTER | |||
| DOWN CELL | |||
| FINAL - BUILDING MISC | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | |||
| ROW FIELD SURVEY /GRADING CERTIFICATION | |||
| ROW - STORMWATER FINAL |
Review History
| Department | Status | Date In | Date Out |
| BLD | HOLD | 07/12/2023 | 07/19/2023 |
| Note: Held By: PATRICK BUCKLEY - (386)986-3786 - PBUCKLEY@PALMCOASTGOV.COM THIS IS THE FOURTH REVIEW OF THIS PERMIT. THE ENGINEER CONTINUES TO OMIT REQUIRED DESIGN INFORMATION AND IS NOT RESPONDING TO BUILDING DIVISION PLAN REVIEW COMMENTS. YOU ARE HEREBY NOTIFIED, THE PLAN REVIEW FEE FOR THIS PERMIT HAS BEEN INCREASED BY 4 TIMES THE ORIGINAL AMOUONT AS ALLOWED BY FLORIDA STATUTE 553.80 (2) (b). 3. PARTIAL REPEAT COMMENT. HANDRAIL DETAIL "A" IS IN VIOLATION OF CODE. PROVIDE CODE COMPLIANT STAIR HANDRAIL DETAIL AS REQUESTED BELOW. Show handrail type (1 or 2), show handrail mounting height, attachment and termination details. R311.7.8. R311.7.8.1. R311.7.8.2, R311.7.8.3, R312.1.2. 7. REPEAT COMMENT: Provide retaining wall design criteria. FBC-Building Section 1605.1.1, 1610.2, 1807.2.1, 1807.2.2, 1807.2.3. Design to be based on full hydrostatic pressure of undrained backfill unless a drainage system is installed in accordance with Section 1805.4.2 and 1805.4.3. Provide drainage details. | |||
| BLD | HOLD | 06/14/2023 | 06/21/2023 |
| Note: Held By: PATRICK BUCKLEY - (386)986-3786 - PBUCKLEY@PALMCOASTGOV.COM THIS IS THE THIRD REVIEW OF THIS PERMIT AND THE ENGINEER CONTINUES TO OMIT REQUIRED DESIGN INFORMATION AND IS NOT RESPONDING TO BUILDING DIVISION PLAN REVIEW COMMENTS. YOU ARE HEREBY NOTIFIED, IF THE ENGINEER FAILS TO FULLY AND COMPLETELY ADDRESS ALL REVIEW COMMENTS BELOW FOR THE NEXT SUBMITTAL, THE PALM COAST BUILDING DIVSION WILL INCREASE THE PLAN REVIEW FEE BY 4 TIMES THE ORIGINAL AMOUONT AS ALLOWED BY FLORIDA STATUTE 553.80 (2) (b). 3. PARTIAL REPEAT COMMENT. HANDRAIL DETAIL "A" IS IN VIOLATION OF CODE. PROVIDE CODE COMPLIANT STAIR HANDRAIL DETAIL AS REQUESTED BELOW. Provide stair section from landing adjacent to new open patio at top of first set of stairs to bottom of first set of stairs and a separate section for the lower set of stairs. Each section to show distance of landing and / or stairs above surrounding grade. Show rise and run, indicate construction materials used for stair construction, show location of handrails, show handrail type (1 or 2), show handrail mounting height, attachment and termination details. R311.7.5.1, R311.7.7 R311.7.8. R311.7.8.1. R311.7.8.2, R311.7.8.3, R311.7.5.2, R312.1.2. 7. REPEAT COMMENT: Provide retaining wall design criteria. FBC-Building Section 1605.1.1, 1610.2, 1807.2.1, 1807.2.2, 1807.2.3. Design to be based on full hydrostatic pressure of undrained backfill unless a drainage system is installed in accordance with Section 1805.4.2 and 1805.4.3. Provide drainage details. NEW COMMENTS BASED ON LATEST SUBMITTAL: PLAN VIEW OF PROJECT INDICATES "8' x 8' OPEN PAVER PATIO" BETWEEN UPPER STAIRS AND LOWER STAIRS. NEW SECTION VIEW ADDED TO PLANS INDICATES "8' x 8' OPEN PAVER PATIO" BUT SHOWS PAVERS SUPPORTED BY A WOOD FRAMED DECK. NO FRAMING AND CONSTRUCTION DETAILS HAVE BEEN PROVIDED FOR THIS OPEN PAVER DECK. R301.4, R301.5 NO DESIGN LOADS PROVIDED FOR THIS DECK OR THE 4' X 4' LANDING ADJACENT TO PATIO. R301.4, R301.5 LANDING ADJACENT TO PATIO INDICATES WOOD HEADER ATTACHED TO SIDES OF DECK POSTS. HEADERS (BEAMS) MUST BE SUPPORTED ON TOP OF POSTS. LANDING ADJACENT TO PATIO AND THIS 8' X 8' PAVER PATIO DECK DO NOT CONTAIN ANY LUMBER SPECIFICATIONS INCLUDING LUMBER SPECIES AND GRADE, JOIST AND BEAM SPANS, BEAM MATERIALS, BEAM ATTACHMENT, JOIST HANGERS, BEAM CONNECTORS AND SIMILAR INFORMATION. 8' X 8 ' DECK SUPPORTING PAVERS IS A MOISTURE PERMEABLE DECK BY DEFINITION AND HAS TO MEET SPECIFIC CONSTRUCTION REQUIREMENTS INCLUDING INCREASED LIVE LOADS DUE TO THE PRESENCE OF PAVERS. R301.4, R301.5. ENTIRE DECK MUST BE CONSTRUCTED OF DECAY RESISTANT OR PRESSURE TREATED WOOD OR SEPARATED FROM WOOD BY AN IMPERVIOUS MOISTURE BARRIER PER SECTION R317.1 NO. 6. NEW SECTION VIEW INDICATES "A", "B" AND "C" SECTIONS / DETAILS BUT PROVIDES NO DETAILS. PROVIDE NUMBER OF STAIR STRINGERS REQUIRED FOR SET OF STAIRS. | |||
| ZON | COMPLETE | 05/16/2023 | 05/16/2023 |
| Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM too match the home | |||
| BLD | HOLD | 05/16/2023 | 05/23/2023 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM 1. REPEAT COMMENT: LANDING DIMENSIONS AT BOTTOM OF LOWER SET OF STAIRS STILL NOT SHOWN. Provide dimensions of landings at top of upper stairs and bottom lower set of stairs. R311.7.6. 3. PARTIAL REPEAT COMMENT. HANDRAIL DETAIL "A" IS IN VIOLATION OF CODE. PROVIDE CODE COMPLIANT STAIR HANDRAIL DETAIL AS REQUESTED BELOW. Provide stair section from landing adjacent to new open patio at top of first set of stairs to bottom of first set of stairs and a separate section for the lower set of stairs. Each section to show distance of landing and / or stairs above surrounding grade. Show rise and run, indicate construction materials used for stair construction, show location of handrails, show handrail type (1 or 2), show handrail mounting height, attachment and termination details. R311.7.5.1, R311.7.7 R311.7.8. R311.7.8.1. R311.7.8.2, R311.7.8.3, R311.7.5.2, R312.1.2. 7. REPEAT COMMENT: Provide retaining wall design criteria. FBC-Building Section 1605.1.1, 1610.2, 1807.2.1, 1807.2.2, 1807.2.3. Design to be based on full hydrostatic pressure of undrained backfill unless a drainage system is installed in accordance with Section 1805.4.2 and 1805.4.3. Provide drainage details. 9. REPEAT COMMENT: Provide patio and retaining wall fill material specifications. | |||
| ZON | HOLD | 04/24/2023 | 04/24/2023 |
| Note: Held By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM 1. Plans must state that the proposed retaining wall will be finished and painted to match the house. | |||
| BLD | HOLD | 04/21/2023 | 04/28/2023 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM 1. Provide dimensions of landings at top of upper stairs and bottom lower set of stairs. R311.7.6. 2. Show width of stairs. R311.7.1 3. Provide stair section from landing adjacent to new open patio at top of first set of stairs to bottom of first set of stairs and a separate section for the lower set of stairs. Each section to show distance of landing and / or stairs above surrounding grade. Show rise and run, indicate construction materials used for stair construction, show location of handrails, show handrail type (1 or 2), show handrail mounting height, attachment and termination details. R311.7.5.1, R311.7.7 R311.7.8. R311.7.8.1. R311.7.8.2, R311.7.8.3, R311.7.5.2, R312.1.2 4. Provide tread depth of 11 inches minimum or provide stair tread nosing detail. R311.7.5.3. 5. Show required guards at new open patio, landing at top of upper set of stairs and for any stairs or landings in the upper and / or lower stair where any part of the stairs or landings are more than 30 inches above surrounding grade within 24 inches of edges of patio, landings and / or stairs. R312.1.1 6. Provide guard construction details including guard construction materials, guard design loads for both the guard and guard in-fill components, guard height, guard top and bottom rails, guard in-fill components materials, maximum openings in guards, complete guard attachment details to landings and stairs. R301.5, Table R301.5, R312.1.2, R312.1.3 7. Provide retaining wall design criteria. FBC-Building Section 1605.1.1, 1610.2, 1807.2.1, 1807.2.2, 1807.2.3. Design to be based on full hydrostatic pressure of undrained backfill unles a drainage system is installed in accordance with Section 1805.4.2 and 1805.4.3. Provide drainage details. 8. Provide patio materials specifications. 9. Provide patio and retainign wall fill material specifications. | |||
| SW1 | COMPLETE | 04/21/2023 | 04/28/2023 |
| Note: Released By: GABRIEL BERTOLA - (386)986-7660 - GBERTOLA@PALMCOASTGOV.COM | |||
| BLD | CANCEL |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| ADJUSTMENT 50% | (¤61.25) | |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | |
| INSPECTION - RESIDENTIAL | ¤60.00 | |
| PLAN REVIEW - MISC 32.50 | ¤32.50 | |
| SURCHARGE FS 533.721 | ¤2.00 | |
| SURCHARGE - FS 468.631 | ¤2.00 | |
| SW ENG - INSPECTION 20 | ¤20.00 | |
| SW ENG - REVIEW 20 | ¤20.00 | |
| SITE PLAN 15 | ¤15.00 | |
| Fees | Total Due: ¤120.25 | Total Paid: ¤0.00 |