I want to search for...

Permit #2023041152

Permit Details

Status: CANCEL

Parcel Id: 07-11-31-7014-00070-1910
Block: 00070
Subdivision: 2202 - SECTION 14-COUNTRY CLUB COVE
Job Phone: 386-338-1859
Location Address: 7 CLEVELAND CT
Type: PA - PATIO/SLAB (STRUCTURAL)
NOC: RECORDED
Applicant name: SOPHAN KES
Owner: CONNOLLY JULIA & WILLIAM W&H

Address

7 CLEVELAND COURT

PALM COAST, FL 32137

Lot: 1910
Contracted Stated Job Value: ¤7,500.00
Job Description: BACK PATIO W/RETAINING WALL
Type: CN

Contractor

KES CONSTRUCTION, INC
Status Location Address State License Number
ACTIVE

42 OAKLEAF WAY

PALM COAST, FL 32137

CBC1264797 (Exp: 08/31/2026)

Inspection History

Type Request Date Result Inspector
MONOLITHIC SLAB
FOOTER
DOWN CELL
FINAL - BUILDING MISC
ROW- FINAL SURVEY/GRADING CERTIFICATION
ROW FIELD SURVEY /GRADING CERTIFICATION
ROW - STORMWATER FINAL

Review History

Department Status Date In Date Out
BLD HOLD 07/12/2023 07/19/2023
Note: Held By: PATRICK BUCKLEY - (386)986-3786 - PBUCKLEY@PALMCOASTGOV.COM THIS IS THE FOURTH REVIEW OF THIS PERMIT. THE ENGINEER CONTINUES TO OMIT REQUIRED DESIGN INFORMATION AND IS NOT RESPONDING TO BUILDING DIVISION PLAN REVIEW COMMENTS. YOU ARE HEREBY NOTIFIED, THE PLAN REVIEW FEE FOR THIS PERMIT HAS BEEN INCREASED BY 4 TIMES THE ORIGINAL AMOUONT AS ALLOWED BY FLORIDA STATUTE 553.80 (2) (b). 3. PARTIAL REPEAT COMMENT. HANDRAIL DETAIL "A" IS IN VIOLATION OF CODE. PROVIDE CODE COMPLIANT STAIR HANDRAIL DETAIL AS REQUESTED BELOW. Show handrail type (1 or 2), show handrail mounting height, attachment and termination details. R311.7.8. R311.7.8.1. R311.7.8.2, R311.7.8.3, R312.1.2. 7. REPEAT COMMENT: Provide retaining wall design criteria. FBC-Building Section 1605.1.1, 1610.2, 1807.2.1, 1807.2.2, 1807.2.3. Design to be based on full hydrostatic pressure of undrained backfill unless a drainage system is installed in accordance with Section 1805.4.2 and 1805.4.3. Provide drainage details.
BLD HOLD 06/14/2023 06/21/2023
Note: Held By: PATRICK BUCKLEY - (386)986-3786 - PBUCKLEY@PALMCOASTGOV.COM THIS IS THE THIRD REVIEW OF THIS PERMIT AND THE ENGINEER CONTINUES TO OMIT REQUIRED DESIGN INFORMATION AND IS NOT RESPONDING TO BUILDING DIVISION PLAN REVIEW COMMENTS. YOU ARE HEREBY NOTIFIED, IF THE ENGINEER FAILS TO FULLY AND COMPLETELY ADDRESS ALL REVIEW COMMENTS BELOW FOR THE NEXT SUBMITTAL, THE PALM COAST BUILDING DIVSION WILL INCREASE THE PLAN REVIEW FEE BY 4 TIMES THE ORIGINAL AMOUONT AS ALLOWED BY FLORIDA STATUTE 553.80 (2) (b). 3. PARTIAL REPEAT COMMENT. HANDRAIL DETAIL "A" IS IN VIOLATION OF CODE. PROVIDE CODE COMPLIANT STAIR HANDRAIL DETAIL AS REQUESTED BELOW. Provide stair section from landing adjacent to new open patio at top of first set of stairs to bottom of first set of stairs and a separate section for the lower set of stairs. Each section to show distance of landing and / or stairs above surrounding grade. Show rise and run, indicate construction materials used for stair construction, show location of handrails, show handrail type (1 or 2), show handrail mounting height, attachment and termination details. R311.7.5.1, R311.7.7 R311.7.8. R311.7.8.1. R311.7.8.2, R311.7.8.3, R311.7.5.2, R312.1.2. 7. REPEAT COMMENT: Provide retaining wall design criteria. FBC-Building Section 1605.1.1, 1610.2, 1807.2.1, 1807.2.2, 1807.2.3. Design to be based on full hydrostatic pressure of undrained backfill unless a drainage system is installed in accordance with Section 1805.4.2 and 1805.4.3. Provide drainage details. NEW COMMENTS BASED ON LATEST SUBMITTAL: PLAN VIEW OF PROJECT INDICATES "8' x 8' OPEN PAVER PATIO" BETWEEN UPPER STAIRS AND LOWER STAIRS. NEW SECTION VIEW ADDED TO PLANS INDICATES "8' x 8' OPEN PAVER PATIO" BUT SHOWS PAVERS SUPPORTED BY A WOOD FRAMED DECK. NO FRAMING AND CONSTRUCTION DETAILS HAVE BEEN PROVIDED FOR THIS OPEN PAVER DECK. R301.4, R301.5 NO DESIGN LOADS PROVIDED FOR THIS DECK OR THE 4' X 4' LANDING ADJACENT TO PATIO. R301.4, R301.5 LANDING ADJACENT TO PATIO INDICATES WOOD HEADER ATTACHED TO SIDES OF DECK POSTS. HEADERS (BEAMS) MUST BE SUPPORTED ON TOP OF POSTS. LANDING ADJACENT TO PATIO AND THIS 8' X 8' PAVER PATIO DECK DO NOT CONTAIN ANY LUMBER SPECIFICATIONS INCLUDING LUMBER SPECIES AND GRADE, JOIST AND BEAM SPANS, BEAM MATERIALS, BEAM ATTACHMENT, JOIST HANGERS, BEAM CONNECTORS AND SIMILAR INFORMATION. 8' X 8 ' DECK SUPPORTING PAVERS IS A MOISTURE PERMEABLE DECK BY DEFINITION AND HAS TO MEET SPECIFIC CONSTRUCTION REQUIREMENTS INCLUDING INCREASED LIVE LOADS DUE TO THE PRESENCE OF PAVERS. R301.4, R301.5. ENTIRE DECK MUST BE CONSTRUCTED OF DECAY RESISTANT OR PRESSURE TREATED WOOD OR SEPARATED FROM WOOD BY AN IMPERVIOUS MOISTURE BARRIER PER SECTION R317.1 NO. 6. NEW SECTION VIEW INDICATES "A", "B" AND "C" SECTIONS / DETAILS BUT PROVIDES NO DETAILS. PROVIDE NUMBER OF STAIR STRINGERS REQUIRED FOR SET OF STAIRS.
ZON COMPLETE 05/16/2023 05/16/2023
Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM too match the home
BLD HOLD 05/16/2023 05/23/2023
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM 1. REPEAT COMMENT: LANDING DIMENSIONS AT BOTTOM OF LOWER SET OF STAIRS STILL NOT SHOWN. Provide dimensions of landings at top of upper stairs and bottom lower set of stairs. R311.7.6. 3. PARTIAL REPEAT COMMENT. HANDRAIL DETAIL "A" IS IN VIOLATION OF CODE. PROVIDE CODE COMPLIANT STAIR HANDRAIL DETAIL AS REQUESTED BELOW. Provide stair section from landing adjacent to new open patio at top of first set of stairs to bottom of first set of stairs and a separate section for the lower set of stairs. Each section to show distance of landing and / or stairs above surrounding grade. Show rise and run, indicate construction materials used for stair construction, show location of handrails, show handrail type (1 or 2), show handrail mounting height, attachment and termination details. R311.7.5.1, R311.7.7 R311.7.8. R311.7.8.1. R311.7.8.2, R311.7.8.3, R311.7.5.2, R312.1.2. 7. REPEAT COMMENT: Provide retaining wall design criteria. FBC-Building Section 1605.1.1, 1610.2, 1807.2.1, 1807.2.2, 1807.2.3. Design to be based on full hydrostatic pressure of undrained backfill unless a drainage system is installed in accordance with Section 1805.4.2 and 1805.4.3. Provide drainage details. 9. REPEAT COMMENT: Provide patio and retaining wall fill material specifications.
ZON HOLD 04/24/2023 04/24/2023
Note: Held By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM 1. Plans must state that the proposed retaining wall will be finished and painted to match the house.
BLD HOLD 04/21/2023 04/28/2023
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM 1. Provide dimensions of landings at top of upper stairs and bottom lower set of stairs. R311.7.6. 2. Show width of stairs. R311.7.1 3. Provide stair section from landing adjacent to new open patio at top of first set of stairs to bottom of first set of stairs and a separate section for the lower set of stairs. Each section to show distance of landing and / or stairs above surrounding grade. Show rise and run, indicate construction materials used for stair construction, show location of handrails, show handrail type (1 or 2), show handrail mounting height, attachment and termination details. R311.7.5.1, R311.7.7 R311.7.8. R311.7.8.1. R311.7.8.2, R311.7.8.3, R311.7.5.2, R312.1.2 4. Provide tread depth of 11 inches minimum or provide stair tread nosing detail. R311.7.5.3. 5. Show required guards at new open patio, landing at top of upper set of stairs and for any stairs or landings in the upper and / or lower stair where any part of the stairs or landings are more than 30 inches above surrounding grade within 24 inches of edges of patio, landings and / or stairs. R312.1.1 6. Provide guard construction details including guard construction materials, guard design loads for both the guard and guard in-fill components, guard height, guard top and bottom rails, guard in-fill components materials, maximum openings in guards, complete guard attachment details to landings and stairs. R301.5, Table R301.5, R312.1.2, R312.1.3 7. Provide retaining wall design criteria. FBC-Building Section 1605.1.1, 1610.2, 1807.2.1, 1807.2.2, 1807.2.3. Design to be based on full hydrostatic pressure of undrained backfill unles a drainage system is installed in accordance with Section 1805.4.2 and 1805.4.3. Provide drainage details. 8. Provide patio materials specifications. 9. Provide patio and retainign wall fill material specifications.
SW1 COMPLETE 04/21/2023 04/28/2023
Note: Released By: GABRIEL BERTOLA - (386)986-7660 - GBERTOLA@PALMCOASTGOV.COM
BLD CANCEL

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
ADJUSTMENT 50% (¤61.25)
ADMINISTRATIVE RESIDENTIAL ¤30.00
INSPECTION - RESIDENTIAL ¤60.00
PLAN REVIEW - MISC 32.50 ¤32.50
SURCHARGE FS 533.721 ¤2.00
SURCHARGE - FS 468.631 ¤2.00
SW ENG - INSPECTION 20 ¤20.00
SW ENG - REVIEW 20 ¤20.00
SITE PLAN 15 ¤15.00
Fees Total Due: ¤120.25 Total Paid: ¤0.00