Permit #2023041421

Permit Details

Status: COED

Parcel Id: 07-11-31-7034-01100-0070
CONDITIONED SPACE: 2630 sqft
GARAGE: 726 sqft
OPENED PORCH (WITH ROOF) : 721 sqft
OPENED PORCH (WITH ROOF) : 51 sqft
Total Square Footage: 4128 sqft
Block: 01100
Subdivision: 2165 - SECTION 34-EASTHAMPTON
Job Phone: 386-569-7882
Location Address: 88 ERIC DR
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 06/12/2023
NOC: RECORDED
Applicant name: VLADIMIR V PEREPECHKIN
Owner: DUMBAULD, CECILLE & JAMES

Address

71 BECKNER LANE

PALM COAST, FL 32137

Lot: 0070
Contracted Stated Job Value: ¤350,000.00
Job Description: SINGLE FAMILY RESIDENCE
Type: CN

Contractor

WISE CHOICE CUSTOM HOMES, INC.
Status Location Address State License Number Phone
ACTIVE

77 SOUTHLAKE DR

PALM COAST, FL 32137

CRC1328738 (Exp: 08/31/2026) 386-569-7882

Sub Contractors

OLEG BELINSKIY
Status Location Address State License Number Phone
ACTIVE

19 PINE CIRCLE DRIVE19

PALM COAST, FL 32167

CCC1325974 (Exp: 08/31/2026) 386-263-7906
MAXIM BUDNIK
Status Location Address State License Number
ACTIVE

3 WAVECREST PL

PALM COAST, FL 32164

CAC1818445 (Exp: 08/31/2026)
MAXIM BUDNIK
Status Location Address State License Number Phone
ACTIVE

9788 HALSEY RD

JACKSONVILLE, FL 32246

EC13007415 (Exp: 08/31/2026) 904-509-7306
JUAN CARLOS GONZALEZ
Status Location Address State License Number
ACTIVE

1328 COUNTY ROAD 308

CRESCENT CITY, FL 32112

RF11067806 (Exp: 08/31/2027)
ANDREW GONCALVES HOWARD
Status Location Address State License Number Phone
ACTIVE

2 RYALL LANE

PALM COAST, FL 32164

CCC1333989 (Exp: 08/31/2026) 386-347-0366

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 03/26/2024 FINAL APPROVED RSIMS
Note: 3/25/2024 - PREVIOUS INSPECTION NOTES 3-25-24 The following item is still unresolved from the prior lists 10). Bathroom exhaust pipes are still not connected properly to the soffit exhaust termination per FBC-R, M1501.1 3/22/2024 - PREVIOUS INSPECTION NOTES Previously noted items have been resolved. Outlets cannot inside cabinets for kitchen island service 3/21/2024 - PREVIOUS INSPECTION NOTES 3/21/24: Need to fully resolve previous items before Building Final Approval. Previously listed items: 8) hole in garage wall to ceiling is not fully sealed as required. (left side of garage door from inside). 9). Water heater installed after All Rough has now reduced the clear space in front of the Breaker box (as noted previously). 10). Bathroom exhaust pipes are still not connected properly to the soffit exhaust termination. 3/18/2024 - PREVIOUS INSPECTION NOTES 3/18/24: 1). Outside island: Outlet for refigerator is not weather rated as required. 2). Guest bathroom: Tub spout is not sealed at the wall as required. ( FBC-P2705.1(3)). 3). Dishwasher is not plugged in. 4). Garabage disposal is not wired with cord & plug. (new cord laying in bottom of cabinet). 5). MC cable feeding switch for Garbage disposal need to be securely anchored. 6). Garage door safety eyes are over the 6" max from finished floor (UL 325.6 /16CFR part 1211). 7). Interior Garage door missing seal on the right side (from garage). 8). Holes in garage wall & ceiling needs to be sealed with the appropriate material per fire code (FBC302.11). 9). Breaker box still does not have the proper clearance with the water heater in place as required by NEC Section 110.26(A) requires a clear space at least 30 inches wide and 36 inches deep if the equipment is likely to be worked on while energized.  10). Bathroom exhaust pipes are crushed/not installed fully at the soffit vent on the left side of the house. 11). Hole in cinderblock wall at irrigation control wire PVC sleeve needs to be sealed. (right side). 12). Dryer box needs to be sealed around the perimeter where it meets drywall as part of the thermal barrier. 13). Please seal around the service mast pipes where they enter the attic area through the soffit.
BLD - BUILDING FINAL 03/25/2024 Disapproved -FEE REQUIRED LMILLER
Note: 3-25-24 The following item is still unresolved from the prior lists 10). Bathroom exhaust pipes are still not connected properly to the soffit exhaust termination per FBC-R, M1501.1 3/22/2024 - PREVIOUS INSPECTION NOTES Previously noted items have been resolved. Outlets cannot inside cabinets for kitchen island service 3/21/2024 - PREVIOUS INSPECTION NOTES 3/21/24: Need to fully resolve previous items before Building Final Approval. Previously listed items: 8) hole in garage wall to ceiling is not fully sealed as required. (left side of garage door from inside). 9). Water heater installed after All Rough has now reduced the clear space in front of the Breaker box (as noted previously). 10). Bathroom exhaust pipes are still not connected properly to the soffit exhaust termination. 3/18/2024 - PREVIOUS INSPECTION NOTES 3/18/24: 1). Outside island: Outlet for refigerator is not weather rated as required. 2). Guest bathroom: Tub spout is not sealed at the wall as required. ( FBC-P2705.1(3)). 3). Dishwasher is not plugged in. 4). Garabage disposal is not wired with cord & plug. (new cord laying in bottom of cabinet). 5). MC cable feeding switch for Garbage disposal need to be securely anchored. 6). Garage door safety eyes are over the 6" max from finished floor (UL 325.6 /16CFR part 1211). 7). Interior Garage door missing seal on the right side (from garage). 8). Holes in garage wall & ceiling needs to be sealed with the appropriate material per fire code (FBC302.11). 9). Breaker box still does not have the proper clearance with the water heater in place as required by NEC Section 110.26(A) requires a clear space at least 30 inches wide and 36 inches deep if the equipment is likely to be worked on while energized.  10). Bathroom exhaust pipes are crushed/not installed fully at the soffit vent on the left side of the house. 11). Hole in cinderblock wall at irrigation control wire PVC sleeve needs to be sealed. (right side). 12). Dryer box needs to be sealed around the perimeter where it meets drywall as part of the thermal barrier. 13). Please seal around the service mast pipes where they enter the attic area through the soffit.
BLD - BUILDING FINAL 03/22/2024 Disapproved - NO FEE KSANDOE
Note: Previously noted items have been resolved. Outlets cannot inside cabinets for kitchen island service 3/21/2024 - PREVIOUS INSPECTION NOTES 3/21/24: Need to fully resolve previous items before Building Final Approval. Previously listed items: 8) hole in garage wall to ceiling is not fully sealed as required. (left side of garage door from inside). 9). Water heater installed after All Rough has now reduced the clear space in front of the Breaker box (as noted previously). 10). Bathroom exhaust pipes are still not connected properly to the soffit exhaust termination. 3/18/2024 - PREVIOUS INSPECTION NOTES 3/18/24: 1). Outside island: Outlet for refigerator is not weather rated as required. 2). Guest bathroom: Tub spout is not sealed at the wall as required. ( FBC-P2705.1(3)). 3). Dishwasher is not plugged in. 4). Garabage disposal is not wired with cord & plug. (new cord laying in bottom of cabinet). 5). MC cable feeding switch for Garbage disposal need to be securely anchored. 6). Garage door safety eyes are over the 6" max from finished floor (UL 325.6 /16CFR part 1211). 7). Interior Garage door missing seal on the right side (from garage). 8). Holes in garage wall & ceiling needs to be sealed with the appropriate material per fire code (FBC302.11). 9). Breaker box still does not have the proper clearance with the water heater in place as required by NEC Section 110.26(A) requires a clear space at least 30 inches wide and 36 inches deep if the equipment is likely to be worked on while energized.  10). Bathroom exhaust pipes are crushed/not installed fully at the soffit vent on the left side of the house. 11). Hole in cinderblock wall at irrigation control wire PVC sleeve needs to be sealed. (right side). 12). Dryer box needs to be sealed around the perimeter where it meets drywall as part of the thermal barrier. 13). Please seal around the service mast pipes where they enter the attic area through the soffit.
BLD - BUILDING FINAL 03/21/2024 Disapproved - NO FEE RSIMS
Note: 3/21/24: Need to fully resolve previous items before Building Final Approval. Previously listed items: 8) hole in garage wall to ceiling is not fully sealed as required. (left side of garage door from inside). 9). Water heater installed after All Rough has now reduced the clear space in front of the Breaker box (as noted previously). 10). Bathroom exhaust pipes are still not connected properly to the soffit exhaust termination. 3/18/2024 - PREVIOUS INSPECTION NOTES 3/18/24: 1). Outside island: Outlet for refigerator is not weather rated as required. 2). Guest bathroom: Tub spout is not sealed at the wall as required. ( FBC-P2705.1(3)). 3). Dishwasher is not plugged in. 4). Garabage disposal is not wired with cord & plug. (new cord laying in bottom of cabinet). 5). MC cable feeding switch for Garbage disposal need to be securely anchored. 6). Garage door safety eyes are over the 6" max from finished floor (UL 325.6 /16CFR part 1211). 7). Interior Garage door missing seal on the right side (from garage). 8). Holes in garage wall & ceiling needs to be sealed with the appropriate material per fire code (FBC302.11). 9). Breaker box still does not have the proper clearance with the water heater in place as required by NEC Section 110.26(A) requires a clear space at least 30 inches wide and 36 inches deep if the equipment is likely to be worked on while energized.  10). Bathroom exhaust pipes are crushed/not installed fully at the soffit vent on the left side of the house. 11). Hole in cinderblock wall at irrigation control wire PVC sleeve needs to be sealed. (right side). 12). Dryer box needs to be sealed around the perimeter where it meets drywall as part of the thermal barrier. 13). Please seal around the service mast pipes where they enter the attic area through the soffit.
BLD - BUILDING FINAL 03/18/2024 Disapproved -FEE REQUIRED RSIMS
Note: 3/18/24: 1). Outside island: Outlet for refigerator is not weather rated as required. 2). Guest bathroom: Tub spout is not sealed at the wall as required. ( FBC-P2705.1(3)). 3). Dishwasher is not plugged in. 4). Garabage disposal is not wired with cord & plug. (new cord laying in bottom of cabinet). 5). MC cable feeding switch for Garbage disposal need to be securely anchored. 6). Garage door safety eyes are over the 6" max from finished floor (UL 325.6 /16CFR part 1211). 7). Interior Garage door missing seal on the right side (from garage). 8). Holes in garage wall & ceiling needs to be sealed with the appropriate material per fire code (FBC302.11). 9). Breaker box still does not have the proper clearance with the water heater in place as required by NEC Section 110.26(A) requires a clear space at least 30 inches wide and 36 inches deep if the equipment is likely to be worked on while energized.  10). Bathroom exhaust pipes are crushed/not installed fully at the soffit vent on the left side of the house. 11). Hole in cinderblock wall at irrigation control wire PVC sleeve needs to be sealed. (right side). 12). Dryer box needs to be sealed around the perimeter where it meets drywall as part of the thermal barrier. 13). Please seal around the service mast pipes where they enter the attic area through the soffit.
ROW - STORMWATER FINAL 03/15/2024 APPROVED PFLANAGAN
Note: CORRECTIONS MADE -------------------------------------------------------------------------------------- 3/14/2024 - PREVIOUS INSPECTION NOTES STILL NEED TO FIXS THE RUTS AND GRADE ROADSIDE SWALE IN THE VACANT LOT TO THE RIGHT WHEN SODDING ALL SOD NEED TO BE MATCHING GRADE ---------------------------------------------------------------------------------------- 3/8/2024 - PREVIOUS INSPECTION NOTES 3/5/2024 - PREVIOUS INSPECTION NOTES 1) NEED TO REMOVE THE PORTER JOHN FROM THE RIGHT OF WAY 2) ROADSIDE SWALE TO THE RIGHT OF YOUR LOT IN THE VACANT NEEDS TO BE GRADED AND REPAIRED WITH SOD. ALL SOD NEEDS TO MATCH EXISTING GRADE SURROUNDING IT. 3) NEED TO PICK UP ALL TRASH AND CONSTRUCTION DEBRIS FROM VACANT TO THE RIGHT OF YOUR LOT. ---------------------------------------------------------------------------------- 2/23/2024 - PREVIOUS INSPECTION NOTES 2/23/24 PORTA POTTY IS IN THE ROW. NEED TO REMOVE IT AND REPAIR/SOD WHERE IT IS SITTING. THE SWALE ON THE RIGHT SIDE NEEDS TO BE CLEANED UP SOD LAID ON ALL BARE AREAS AND GRADED. THE SOD AT ROAD EDGE IS HIGH, NEEDS TO BE EVEN WITH THE ROAD EDGE AND SLOPED TO MATCH GRADE OF SWALE. YOU HAVE A HIGH SPOT IN THE SWALE HOLDING WATER, THIS NEEDS TO BE CORRECTED TO MATCH GRADE AND ALLOW SWALE TO HAVE POSITIVE DRAINAGE. THIS AREA NEEDS TO BE CLEANED UP, SODDED AND GRADED TO MATCH. SEE PHOTOS FOR REFERENCE. I WILL NOT FEE YOU TODAY AS I WAS HERE FOR AN AFTERPOUR INSPECTION ALREADY. PLEASE MAKE CORRECTIONS BEFORE RESUBMITTING FOR ROW FINAL INSPECTION. Inspector Notes from Inspection 9465 2/22/24 UPON WALKING PROPERTY DETERMINED THAT YOU WILL NEED TO REMOVE/RELOCATE TREE ON THE REAR LEFT PROPERTY CORNER AS IT IS DIRECTLY IN THE DRAINAGE CONVEYANCE OF THE YARD. RIGHT SIDE OUTLINED AREA YOU WILL NEED TO PUT A ROW OF SOD AS WELL TO MAINTAIN THE DRAINAGE CONVEYANCE. I WILL APPROVE THIS FIELD SURVEY AS A COURTESY TO MOVE FORWARD, BUT THESE CORRECTIONS AND ANY OTHER DEEMED NECCESSARY ON SUBSEQUENT INSPECTIONS WILL NEED TO BE MADE BEFORE ROW FINAL PASSAGE.
ROW - STORMWATER FINAL 03/14/2024 Disapproved -FEE REQUIRED PFLANAGAN
Note: STILL NEED TO FIXS THE RUTS AND GRADE ROADSIDE SWALE IN THE VACANT LOT TO THE RIGHT WHEN SODDING ALL SOD NEED TO BE MATCHING GRADE ---------------------------------------------------------------------------------------- 3/8/2024 - PREVIOUS INSPECTION NOTES 3/5/2024 - PREVIOUS INSPECTION NOTES 1) NEED TO REMOVE THE PORTER JOHN FROM THE RIGHT OF WAY 2) ROADSIDE SWALE TO THE RIGHT OF YOUR LOT IN THE VACANT NEEDS TO BE GRADED AND REPAIRED WITH SOD. ALL SOD NEEDS TO MATCH EXISTING GRADE SURROUNDING IT. 3) NEED TO PICK UP ALL TRASH AND CONSTRUCTION DEBRIS FROM VACANT TO THE RIGHT OF YOUR LOT. ---------------------------------------------------------------------------------- 2/23/2024 - PREVIOUS INSPECTION NOTES 2/23/24 PORTA POTTY IS IN THE ROW. NEED TO REMOVE IT AND REPAIR/SOD WHERE IT IS SITTING. THE SWALE ON THE RIGHT SIDE NEEDS TO BE CLEANED UP SOD LAID ON ALL BARE AREAS AND GRADED. THE SOD AT ROAD EDGE IS HIGH, NEEDS TO BE EVEN WITH THE ROAD EDGE AND SLOPED TO MATCH GRADE OF SWALE. YOU HAVE A HIGH SPOT IN THE SWALE HOLDING WATER, THIS NEEDS TO BE CORRECTED TO MATCH GRADE AND ALLOW SWALE TO HAVE POSITIVE DRAINAGE. THIS AREA NEEDS TO BE CLEANED UP, SODDED AND GRADED TO MATCH. SEE PHOTOS FOR REFERENCE. I WILL NOT FEE YOU TODAY AS I WAS HERE FOR AN AFTERPOUR INSPECTION ALREADY. PLEASE MAKE CORRECTIONS BEFORE RESUBMITTING FOR ROW FINAL INSPECTION. Inspector Notes from Inspection 9465 2/22/24 UPON WALKING PROPERTY DETERMINED THAT YOU WILL NEED TO REMOVE/RELOCATE TREE ON THE REAR LEFT PROPERTY CORNER AS IT IS DIRECTLY IN THE DRAINAGE CONVEYANCE OF THE YARD. RIGHT SIDE OUTLINED AREA YOU WILL NEED TO PUT A ROW OF SOD AS WELL TO MAINTAIN THE DRAINAGE CONVEYANCE. I WILL APPROVE THIS FIELD SURVEY AS A COURTESY TO MOVE FORWARD, BUT THESE CORRECTIONS AND ANY OTHER DEEMED NECCESSARY ON SUBSEQUENT INSPECTIONS WILL NEED TO BE MADE BEFORE ROW FINAL PASSAGE.
ROW - STORMWATER FINAL 03/08/2024 CANCELLED BY APPLICANT EMADISON
Note: 3/5/2024 - PREVIOUS INSPECTION NOTES 1) NEED TO REMOVE THE PORTER JOHN FROM THE RIGHT OF WAY 2) ROADSIDE SWALE TO THE RIGHT OF YOUR LOT IN THE VACANT NEEDS TO BE GRADED AND REPAIRED WITH SOD. ALL SOD NEEDS TO MATCH EXISTING GRADE SURROUNDING IT. 3) NEED TO PICK UP ALL TRASH AND CONSTRUCTION DEBRIS FROM VACANT TO THE RIGHT OF YOUR LOT. ---------------------------------------------------------------------------------- 2/23/2024 - PREVIOUS INSPECTION NOTES 2/23/24 PORTA POTTY IS IN THE ROW. NEED TO REMOVE IT AND REPAIR/SOD WHERE IT IS SITTING. THE SWALE ON THE RIGHT SIDE NEEDS TO BE CLEANED UP SOD LAID ON ALL BARE AREAS AND GRADED. THE SOD AT ROAD EDGE IS HIGH, NEEDS TO BE EVEN WITH THE ROAD EDGE AND SLOPED TO MATCH GRADE OF SWALE. YOU HAVE A HIGH SPOT IN THE SWALE HOLDING WATER, THIS NEEDS TO BE CORRECTED TO MATCH GRADE AND ALLOW SWALE TO HAVE POSITIVE DRAINAGE. THIS AREA NEEDS TO BE CLEANED UP, SODDED AND GRADED TO MATCH. SEE PHOTOS FOR REFERENCE. I WILL NOT FEE YOU TODAY AS I WAS HERE FOR AN AFTERPOUR INSPECTION ALREADY. PLEASE MAKE CORRECTIONS BEFORE RESUBMITTING FOR ROW FINAL INSPECTION. Inspector Notes from Inspection 9465 2/22/24 UPON WALKING PROPERTY DETERMINED THAT YOU WILL NEED TO REMOVE/RELOCATE TREE ON THE REAR LEFT PROPERTY CORNER AS IT IS DIRECTLY IN THE DRAINAGE CONVEYANCE OF THE YARD. RIGHT SIDE OUTLINED AREA YOU WILL NEED TO PUT A ROW OF SOD AS WELL TO MAINTAIN THE DRAINAGE CONVEYANCE. I WILL APPROVE THIS FIELD SURVEY AS A COURTESY TO MOVE FORWARD, BUT THESE CORRECTIONS AND ANY OTHER DEEMED NECCESSARY ON SUBSEQUENT INSPECTIONS WILL NEED TO BE MADE BEFORE ROW FINAL PASSAGE.
ROW - STORMWATER FINAL 03/05/2024 Disapproved -FEE REQUIRED PFLANAGAN
Note: 1) NEED TO REMOVE THE PORTER JOHN FROM THE RIGHT OF WAY 2) ROADSIDE SWALE TO THE RIGHT OF YOUR LOT IN THE VACANT NEEDS TO BE GRADED AND REPAIRED WITH SOD. ALL SOD NEEDS TO MATCH EXISTING GRADE SURROUNDING IT. 3) NEED TO PICK UP ALL TRASH AND CONSTRUCTION DEBRIS FROM VACANT TO THE RIGHT OF YOUR LOT. ---------------------------------------------------------------------------------- 2/23/2024 - PREVIOUS INSPECTION NOTES 2/23/24 PORTA POTTY IS IN THE ROW. NEED TO REMOVE IT AND REPAIR/SOD WHERE IT IS SITTING. THE SWALE ON THE RIGHT SIDE NEEDS TO BE CLEANED UP SOD LAID ON ALL BARE AREAS AND GRADED. THE SOD AT ROAD EDGE IS HIGH, NEEDS TO BE EVEN WITH THE ROAD EDGE AND SLOPED TO MATCH GRADE OF SWALE. YOU HAVE A HIGH SPOT IN THE SWALE HOLDING WATER, THIS NEEDS TO BE CORRECTED TO MATCH GRADE AND ALLOW SWALE TO HAVE POSITIVE DRAINAGE. THIS AREA NEEDS TO BE CLEANED UP, SODDED AND GRADED TO MATCH. SEE PHOTOS FOR REFERENCE. I WILL NOT FEE YOU TODAY AS I WAS HERE FOR AN AFTERPOUR INSPECTION ALREADY. PLEASE MAKE CORRECTIONS BEFORE RESUBMITTING FOR ROW FINAL INSPECTION. Inspector Notes from Inspection 9465 2/22/24 UPON WALKING PROPERTY DETERMINED THAT YOU WILL NEED TO REMOVE/RELOCATE TREE ON THE REAR LEFT PROPERTY CORNER AS IT IS DIRECTLY IN THE DRAINAGE CONVEYANCE OF THE YARD. RIGHT SIDE OUTLINED AREA YOU WILL NEED TO PUT A ROW OF SOD AS WELL TO MAINTAIN THE DRAINAGE CONVEYANCE. I WILL APPROVE THIS FIELD SURVEY AS A COURTESY TO MOVE FORWARD, BUT THESE CORRECTIONS AND ANY OTHER DEEMED NECCESSARY ON SUBSEQUENT INSPECTIONS WILL NEED TO BE MADE BEFORE ROW FINAL PASSAGE.
U -UTILITY RESIDENTIAL FINAL 03/05/2024 FINAL APPROVED JHARDING
Note: 2/23/2024 - PREVIOUS INSPECTION NOTES Inspector Notes from Inspection 9035 has potable irrigatin with PVB-no cross connection no power to pep panel/need access to garage-inspect pep breaker
ELECTRIC - EARLY POWER 02/26/2024 APPROVED RSIMS
Note: 2/26/24: FPL emailed to release power.
U-CROSS CONNECTION 02/23/2024 APPROVED - AS NOTED LFITZGERALD
Note: has potable irrigatin with PVB-no cross connection
ROW - FINAL APRON (AFTER POUR) 02/23/2024 APPROVED - AS NOTED FSLADISH
Note: 2/23/24 NOTING PIPE IS 5 HUNDRETHS LOW OOT ON DOWNSTREAM END ON SURVEY. CUTS MADE. CULVERT NEEDS CLEARED ON RIGHT SIDE. HOT PATCH COMPLETED. APPROVING THIS AS NOTED. Inspector Notes from Inspection 9465 2/22/24 UPON WALKING PROPERTY DETERMINED THAT YOU WILL NEED TO REMOVE/RELOCATE TREE ON THE REAR LEFT PROPERTY CORNER AS IT IS DIRECTLY IN THE DRAINAGE CONVEYANCE OF THE YARD. RIGHT SIDE OUTLINED AREA YOU WILL NEED TO PUT A ROW OF SOD AS WELL TO MAINTAIN THE DRAINAGE CONVEYANCE. I WILL APPROVE THIS FIELD SURVEY AS A COURTESY TO MOVE FORWARD, BUT THESE CORRECTIONS AND ANY OTHER DEEMED NECCESSARY ON SUBSEQUENT INSPECTIONS WILL NEED TO BE MADE BEFORE ROW FINAL PASSAGE.
U -UTILITY RESIDENTIAL FINAL 02/23/2024 Disapproved -FEE REQUIRED LFITZGERALD
Note: Inspector Notes from Inspection 9035 has potable irrigatin with PVB-no cross connection no power to pep panel/need access to garage-inspect pep breaker
ROW - STORMWATER FINAL 02/23/2024 Disapproved - NO FEE FSLADISH
Note: 2/23/24 PORTA POTTY IS IN THE ROW. NEED TO REMOVE IT AND REPAIR/SOD WHERE IT IS SITTING. THE SWALE ON THE RIGHT SIDE NEEDS TO BE CLEANED UP SOD LAID ON ALL BARE AREAS AND GRADED. THE SOD AT ROAD EDGE IS HIGH, NEEDS TO BE EVEN WITH THE ROAD EDGE AND SLOPED TO MATCH GRADE OF SWALE. YOU HAVE A HIGH SPOT IN THE SWALE HOLDING WATER, THIS NEEDS TO BE CORRECTED TO MATCH GRADE AND ALLOW SWALE TO HAVE POSITIVE DRAINAGE. THIS AREA NEEDS TO BE CLEANED UP, SODDED AND GRADED TO MATCH. SEE PHOTOS FOR REFERENCE. I WILL NOT FEE YOU TODAY AS I WAS HERE FOR AN AFTERPOUR INSPECTION ALREADY. PLEASE MAKE CORRECTIONS BEFORE RESUBMITTING FOR ROW FINAL INSPECTION. Inspector Notes from Inspection 9465 2/22/24 UPON WALKING PROPERTY DETERMINED THAT YOU WILL NEED TO REMOVE/RELOCATE TREE ON THE REAR LEFT PROPERTY CORNER AS IT IS DIRECTLY IN THE DRAINAGE CONVEYANCE OF THE YARD. RIGHT SIDE OUTLINED AREA YOU WILL NEED TO PUT A ROW OF SOD AS WELL TO MAINTAIN THE DRAINAGE CONVEYANCE. I WILL APPROVE THIS FIELD SURVEY AS A COURTESY TO MOVE FORWARD, BUT THESE CORRECTIONS AND ANY OTHER DEEMED NECCESSARY ON SUBSEQUENT INSPECTIONS WILL NEED TO BE MADE BEFORE ROW FINAL PASSAGE.
ROW- FINAL SURVEY/GRADING CERTIFICATION 02/22/2024 APPROVED FSLADISH
Note: Inspector Notes from Inspection 9270 01/18/24 PLEASE MAKE SURE ALL AREAS ARE PUMPED DRY OF ANY STANDING WATER. YOU MUST MAINTAIN 6" OF CONCRETE FROM EDGE OF ROAD TO ROW THEN 4" MINIMUM FROM THERE BACK. YOU MAY BEED TO RKE OF GRADE THE CENTER OF DRIVEWAY TO KNOCK DOWN ANY HIGH SPOTS. APPROVING AS NOTED AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING.
ROW FIELD SURVEY /GRADING CERTIFICATION 02/22/2024 APPROVED - AS NOTED FSLADISH
Note: 2/22/24 UPON WALKING PROPERTY DETERMINED THAT YOU WILL NEED TO REMOVE/RELOCATE TREE ON THE REAR LEFT PROPERTY CORNER AS IT IS DIRECTLY IN THE DRAINAGE CONVEYANCE OF THE YARD. RIGHT SIDE OUTLINED AREA YOU WILL NEED TO PUT A ROW OF SOD AS WELL TO MAINTAIN THE DRAINAGE CONVEYANCE. I WILL APPROVE THIS FIELD SURVEY AS A COURTESY TO MOVE FORWARD, BUT THESE CORRECTIONS AND ANY OTHER DEEMED NECCESSARY ON SUBSEQUENT INSPECTIONS WILL NEED TO BE MADE BEFORE ROW FINAL PASSAGE.
ROW- PRE-APRON (PRE-POUR) 01/18/2024 APPROVED - AS NOTED TPOLACEK
Note: 01/18/24 PLEASE MAKE SURE ALL AREAS ARE PUMPED DRY OF ANY STANDING WATER. YOU MUST MAINTAIN 6" OF CONCRETE FROM EDGE OF ROAD TO ROW THEN 4" MINIMUM FROM THERE BACK. YOU MAY BEED TO RKE OF GRADE THE CENTER OF DRIVEWAY TO KNOCK DOWN ANY HIGH SPOTS. APPROVING AS NOTED AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING.
U - SEWER TIE IN 01/05/2024 APPROVED MGIBSON
Note: Inspector Notes from Inspection 2060 PROVIDE PORTABLE RESTROOM BEFORE SCHEDULING MONOLITHIC SLAB INSPECTION
GRAVITY SEWER TEST 01/05/2024 APPROVED MGIBSON
Note: Inspector Notes from Inspection 2060 PROVIDE PORTABLE RESTROOM BEFORE SCHEDULING MONOLITHIC SLAB INSPECTION
PEP TANK INSTALLATION REQUEST 12/13/2023 APPROVED BVITALE
LATH/BRICK/ WATER BARRIER 11/30/2023 APPROVED JWALKER
Note: 11/28/2023 - PREVIOUS INSPECTION NOTES 11/28/23: * Wire lath at front entry is still not corrected as required. * Romex wire on right side of the house & holes at lanai kitchen are still not resolved. 11/22/2023 - PREVIOUS INSPECTION NOTES 11/22/23: Previous deficiencies not resolved. Item 1: not resolved. Lath remains vertical. item 2: wire lath needed at all penetrations through block for wires, etc. (tar paper pushed into hole is not an approved process). Holes at back porch area also require wire lath. Item 3: Ufer ground needs to remain accessible with a weather rated cover after stucco is complete.Please remove the wire lath and install a 'Plaster ring' that accepts a blank cover. 11/20/2023 - PREVIOUS INSPECTION NOTES 11/20/23: * Wire lath at left & right walls above the entry is installed vertically. - Wire lath must be installed perpendicular to framing (horizontally) as required by the Manufacturer, The Stucco Institute, The Stucco Manufacturer's Association and ASTM C1063-22. * Missing wire lath at romex on right & low voltage on left side. * Missing plaster ring for Ufer ground on right side. Inspector Notes from Inspection 2420 1. Interior electrical sub panel is to have clear work space of 36" deep by 30" wide. HVAC and Water heater will be in the work space. 2. Rear door and front door not installed . Check for corrections at Insulation inspection.
INSULATION 11/30/2023 APPROVED JWALKER
Note: 11/28/2023 - PREVIOUS INSPECTION NOTES 11/28/23: *Still missing firestop at Horizontal runs. * Electrical Breaker box clearance is still not fully resolved. New inspection due to canceled inspection 11/22/2023 - PREVIOUS INSPECTION NOTES 11/22/23: Previous deficiencies not fully resolved. * Still missing firestop at horizontal runs. * 2"xs added to front entry area need firestop along separations between boards. * Also, modified AHU deck still does not provide the required spacing for the electrical breaker panel as previously noted. 11/20/2023 - PREVIOUS INSPECTION NOTES 11/20/23: Previously listed deficiency is not resolved. * Missing or inadequte firestop in numerous places. Marked with FS on studs below areas. * Blocking above entry between framing and at bathroom pack out wall is under the required thickness for Fire blocking. (1-1/2" minimum). (FBC-R302.11.1) * Missing Firestop at Horizontal wire runs over 10ft. Per FBC 302.11: Required Locations (1.2. Horizontally at intervals not exceeding 10 feet (3048 mm)). (FBC-R302.11/ UL723). * Missing cardboard baffles at all ceiling level changes as required. Inspector Notes from Inspection 2420 1. Interior electrical sub panel is to have clear work space of 36" deep by 30" wide. HVAC and Water heater will be in the work space. 2. Rear door and front door not installed . Check for corrections at Insulation inspection.
INSULATION 11/28/2023 Disapproved -FEE REQUIRED RSIMS
Note: 11/28/23: *Still missing firestop at Horizontal runs. * Electrical Breaker box clearance is still not fully resolved. New inspection due to canceled inspection 11/22/2023 - PREVIOUS INSPECTION NOTES 11/22/23: Previous deficiencies not fully resolved. * Still missing firestop at horizontal runs. * 2"xs added to front entry area need firestop along separations between boards. * Also, modified AHU deck still does not provide the required spacing for the electrical breaker panel as previously noted. 11/20/2023 - PREVIOUS INSPECTION NOTES 11/20/23: Previously listed deficiency is not resolved. * Missing or inadequte firestop in numerous places. Marked with FS on studs below areas. * Blocking above entry between framing and at bathroom pack out wall is under the required thickness for Fire blocking. (1-1/2" minimum). (FBC-R302.11.1) * Missing Firestop at Horizontal wire runs over 10ft. Per FBC 302.11: Required Locations (1.2. Horizontally at intervals not exceeding 10 feet (3048 mm)). (FBC-R302.11/ UL723). * Missing cardboard baffles at all ceiling level changes as required. Inspector Notes from Inspection 2420 1. Interior electrical sub panel is to have clear work space of 36" deep by 30" wide. HVAC and Water heater will be in the work space. 2. Rear door and front door not installed . Check for corrections at Insulation inspection.
LATH/BRICK/ WATER BARRIER 11/28/2023 Disapproved -FEE REQUIRED RSIMS
Note: 11/28/23: * Wire lath at front entry is still not corrected as required. * Romex wire on right side of the house & holes at lanai kitchen are still not resolved. 11/22/2023 - PREVIOUS INSPECTION NOTES 11/22/23: Previous deficiencies not resolved. Item 1: not resolved. Lath remains vertical. item 2: wire lath needed at all penetrations through block for wires, etc. (tar paper pushed into hole is not an approved process). Holes at back porch area also require wire lath. Item 3: Ufer ground needs to remain accessible with a weather rated cover after stucco is complete.Please remove the wire lath and install a 'Plaster ring' that accepts a blank cover. 11/20/2023 - PREVIOUS INSPECTION NOTES 11/20/23: * Wire lath at left & right walls above the entry is installed vertically. - Wire lath must be installed perpendicular to framing (horizontally) as required by the Manufacturer, The Stucco Institute, The Stucco Manufacturer's Association and ASTM C1063-22. * Missing wire lath at romex on right & low voltage on left side. * Missing plaster ring for Ufer ground on right side. Inspector Notes from Inspection 2420 1. Interior electrical sub panel is to have clear work space of 36" deep by 30" wide. HVAC and Water heater will be in the work space. 2. Rear door and front door not installed . Check for corrections at Insulation inspection.
INSULATION 11/27/2023 CANCELLED BY APPLICANT WEB
Note: 11/22/2023 - PREVIOUS INSPECTION NOTES 11/22/23: Previous deficiencies not fully resolved. * Still missing firestop at horizontal runs. * 2"xs added to front entry area need firestop along separations between boards. * Also, modified AHU deck still does not provide the required spacing for the electrical breaker panel as previously noted. 11/20/2023 - PREVIOUS INSPECTION NOTES 11/20/23: Previously listed deficiency is not resolved. * Missing or inadequte firestop in numerous places. Marked with FS on studs below areas. * Blocking above entry between framing and at bathroom pack out wall is under the required thickness for Fire blocking. (1-1/2" minimum). (FBC-R302.11.1) * Missing Firestop at Horizontal wire runs over 10ft. Per FBC 302.11: Required Locations (1.2. Horizontally at intervals not exceeding 10 feet (3048 mm)). (FBC-R302.11/ UL723). * Missing cardboard baffles at all ceiling level changes as required. Inspector Notes from Inspection 2420 1. Interior electrical sub panel is to have clear work space of 36" deep by 30" wide. HVAC and Water heater will be in the work space. 2. Rear door and front door not installed . Check for corrections at Insulation inspection.
INSULATION 11/22/2023 Disapproved -FEE REQUIRED RSIMS
Note: 11/22/23: Previous deficiencies not fully resolved. * Still missing firestop at horizontal runs. * 2"xs added to front entry area need firestop along separations between boards. * Also, the modified AHU deck still does not provide the required spacing for the electrical breaker panel as previously noted. 11/20/2023 - PREVIOUS INSPECTION NOTES 11/20/23: Previously listed deficiency is not resolved. * Missing or inadequte firestop in numerous places. Marked with FS on studs below areas. * Blocking above entry between framing and at bathroom pack out wall is under the required thickness for Fire blocking. (1-1/2" minimum). (FBC-R302.11.1) * Missing Firestop at Horizontal wire runs over 10ft. Per FBC 302.11: Required Locations (1.2. Horizontally at intervals not exceeding 10 feet (3048 mm)). (FBC-R302.11/ UL723). * Missing cardboard baffles at all ceiling level changes as required. Inspector Notes from Inspection 2420 1. Interior electrical sub panel is to have clear work space of 36" deep by 30" wide. HVAC and Water heater will be in the work space. 2. Rear door and front door not installed . Check for corrections at Insulation inspection.
LATH/BRICK/ WATER BARRIER 11/22/2023 Disapproved -FEE REQUIRED RSIMS
Note: 11/22/23: Previous deficiencies not resolved. Item 1: not resolved. Lath remains vertical. item 2: wire lath needed at all penetrations through block for wires, etc. (tar paper pushed into hole is not an approved process). Holes at back porch area also require wire lath. Item 3: Ufer ground needs to remain accessible with a weather rated cover after stucco is complete.Please remove the wire lath and install a 'Plaster ring' that accepts a blank cover. 11/20/2023 - PREVIOUS INSPECTION NOTES 11/20/23: * Wire lath at left & right walls above the entry is installed vertically. - Wire lath must be installed perpendicular to framing (horizontally) as required by the Manufacturer, The Stucco Institute, The Stucco Manufacturer's Association and ASTM C1063-22. * Missing wire lath at romex on right & low voltage on left side. * Missing plaster ring for Ufer ground on right side. Inspector Notes from Inspection 2420 1. Interior electrical sub panel is to have clear work space of 36" deep by 30" wide. HVAC and Water heater will be in the work space. 2. Rear door and front door not installed . Check for corrections at Insulation inspection.
LATH/BRICK/ WATER BARRIER 11/20/2023 Disapproved - NO FEE RSIMS
Note: 11/20/23: * Wire lath at left & right walls above the entry is installed vertically. - Wire lath must be installed perpendicular to framing (horizontally) as required by the Manufacturer, The Stucco Institute, The Stucco Manufacturer's Association and ASTM C1063-22. * Missing wire lath at romex on right & low voltage on left side. * Missing plaster ring for Ufer ground on right side. Inspector Notes from Inspection 2420 1. Interior electrical sub panel is to have clear work space of 36" deep by 30" wide. HVAC and Water heater will be in the work space. 2. Rear door and front door not installed . Check for corrections at Insulation inspection.
INSULATION 11/20/2023 Disapproved -FEE REQUIRED RSIMS
Note: 11/20/23: Previously listed deficiency is not resolved. * Missing or inadequte firestop in numerous places. Marked with FS on studs below areas. * Blocking above entry between framing and at bathroom pack out wall is under the required thickness for Fire blocking. (1-1/2" minimum). (FBC-R302.11.1) * Missing Firestop at Horizontal wire runs over 10ft. Per FBC 302.11: Required Locations (1.2. Horizontally at intervals not exceeding 10 feet (3048 mm)). (FBC-R302.11/ UL723). * Missing cardboard baffles at all ceiling level changes as required. Inspector Notes from Inspection 2420 1. Interior electrical sub panel is to have clear work space of 36" deep by 30" wide. HVAC and Water heater will be in the work space. 2. Rear door and front door not installed . Check for corrections at Insulation inspection.
ALL ROUGH 11/13/2023 APPROVED - AS NOTED JWALKER
Note: 1. Interior electrical sub panel is to have clear work space of 36" deep by 30" wide. HVAC and Water heater will be in the work space. 2. Rear door and front door not installed . Check for corrections at Insulation inspection.
ROOF VALLEY & METAL 11/08/2023 APPROVED RSIMS
Note: Inspector Notes from Inspection 2460 11/7/23: Need dumpster on site & trash cleaned up prior to next inspection. 10/23/2023 - PREVIOUS INSPECTION NOTES 10/23/23: 1). Stud walls are not anchored to CMU walls as required in plan detail. Highlighted. 2). Truss B03 in garage is missing 1 of 2 pieces of engineering as required on MiTek. 3). 2" x 6" in garage load bearing wall that is cut/notched for plumbing will require a revision submitted to & approved by the City for an engineer's letter detailing an approved repair.
ROOF SHEATHING / BRACES/TIES/DOWN CELL 11/07/2023 APPROVED - AS NOTED RSIMS
Note: 11/7/23: Need dumpster on site & trash cleaned up prior to next inspection. 10/23/2023 - PREVIOUS INSPECTION NOTES 10/23/23: 1). Stud walls are not anchored to CMU walls as required in plan detail. Highlighted. 2). Truss B03 in garage is missing 1 of 2 pieces of engineering as required on MiTek. 3). 2" x 6" in garage load bearing wall that is cut/notched for plumbing will require a revision submitted to & approved by the City for an engineer's letter detailing an approved repair.
ROOF VALLEY & METAL 11/07/2023 Disapproved -FEE REQUIRED RSIMS
Note: 11/7/23: * Underlayment does not match the nailing pattern per FBC-905.1.1.1(5) (12" / 6"). * 5" x 5" wall flashing is not sealed/anchored properly. Must be sealed to the wall not underlayment & needs to be attached to CMU walls with nails/anchors.
WALL SHEATHING 10/23/2023 APPROVED RSIMS
ROOF SHEATHING / BRACES/TIES/DOWN CELL 10/23/2023 Disapproved -FEE REQUIRED RSIMS
Note: 10/23/23: 1). Stud walls are not anchored to CMU walls as required in plan detail. Highlighted. 2). Truss B03 in garage is missing 1 of 2 pieces of engineering as required on MiTek. 3). 2" x 6" in garage load bearing wall that is cut/notched for plumbing will require a revision submitted to & approved by the City for an engineer's letter detailing an approved repair.
TIE BEAM / LINTEL 09/25/2023 APPROVED RSIMS
FOUND SURVEY APPROVED (OFFICE) 09/11/2023 APPROVED TBAKER
MONOLITHIC SLAB 08/16/2023 APPROVED RSIMS
Note: 8/14/2023 - PREVIOUS INSPECTION NOTES 8/14/23: Deficiencies marked on print. 1). Back right sleeve for future sink drain line is not fully through the footer. 2). Front two column footers need to be cleaned out to provide proper rebar clearance. 3). Dirt cave in at multiple areas in footers. 8/11/2023 - PREVIOUS INSPECTION NOTES 8/11/23: Inspection Stopped! Incomplete (unbound) prints in Permit box. Missing Page 5 of 7.
MONOLITHIC SLAB 08/14/2023 Disapproved -FEE REQUIRED RSIMS
Note: 8/14/23: Deficiencies marked on print. 1). Back right sleeve for future sink drain line is not fully through the footer. 2). Front two column footers need to be cleaned out to provide proper rebar clearance. 3). Dirt cave in at multiple areas in footers. 8/11/2023 - PREVIOUS INSPECTION NOTES 8/11/23: Inspection Stopped! Incomplete (unbound) prints in Permit box. Missing Page 5 of 7.
MONOLITHIC SLAB 08/11/2023 Disapproved - NO FEE RSIMS
Note: 8/11/23: Inspection Stopped! Incomplete (unbound) prints in Permit box. Missing Page 5 of 7.
PLUMBING 1ST ROUGH UNDERGROUND 08/08/2023 APPROVED - AS NOTED MGIBSON
Note: PROVIDE PORTABLE RESTROOM BEFORE SCHEDULING MONOLITHIC SLAB INSPECTION
WATER METER INSTALLATION REQUEST 07/25/2023 APPROVED CBOWERMASTER

Review History

Department Status Date In Date Out
BLD COMPLETE 11/02/2023 11/06/2023
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ZON COMPLETE 09/11/2023 09/11/2023
Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM
ENGIN1 COMPLETE 09/11/2023 09/11/2023
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON HOLD 09/07/2023 09/07/2023
Note: Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM REPEAT COMMENT: Mechanical equipment pad encroaching in platted 5' utility easement.
ENGIN1 COMPLETE 09/07/2023 09/08/2023
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ENGIN1 COMPLETE 08/28/2023 08/29/2023
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON HOLD 08/28/2023 08/29/2023
Note: Held By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM Mechanical equipment pad encroaching in platted 5' utility easement.
BLD COMPLETE 06/27/2023 06/28/2023
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
BLD COMPLETE 06/12/2023 06/12/2023
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
BLD HOLD 06/09/2023 06/10/2023
Note: Held By: JPI 1. Per City Truss Submittal Requirements dated April 15, 2023, provide the truss plan packet signed and sealed by a licensed design professional including a completed shop drawing approval stamp on the truss cover sheet.
BLD HOLD 06/07/2023 06/08/2023
Note: Held By: JPI 1. Per City Truss Submittal Requirements dated April 15, 2023, provide the truss plan packet signed and sealed by a licensed design professional including a completed shop drawing approval stamp. For ease of review, please label this file Truss Summary- Profiles or Truss Calculations or of a similar nomenclature. 107.3.5
ZON COMPLETE 05/16/2023 05/17/2023
Note: Released By: LIBBY MUSGROVE - - LMUSGROVE@PALMCOASTGOV.COM
BLD HOLD 05/16/2023 05/17/2023
Note: Held By: JPI 1. Per City Truss Submittal Requirements dated April 15, 2023, provide the truss plan packet signed and sealed by a licensed design professional. For ease of review, please label this file Truss Summary- Profiles or Truss Calculations or of a similar nomenclature. 107.3.5
ELEC COMPLETE 05/12/2023 05/12/2023
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ZON HOLD 05/12/2023 05/16/2023
Note: Held By: LIBBY MUSGROVE - - LMUSGROVE@PALMCOASTGOV.COM 2nd request - Elevation page 1 is labeled wrong-should say rear elevation Also a french door is shown on the floor plan but the elev plan shows a Slider? (rear view side)
MECH COMPLETE 05/09/2023 05/09/2023
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
ELEC HOLD 05/09/2023 05/09/2023
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Need correct outlet spacing NEC 2017 210.52 bed 3 and bed 2 behind doors
ENGIN1 COMPLETE 05/09/2023 05/10/2023
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
SW1 COMPLETE 05/09/2023 05/15/2023
Note: Released By: EDWARD MADISON - - EMADISON@PALMCOASTGOV.COM
ZON HOLD 05/09/2023 05/12/2023
Note: Held By: LIBBY MUSGROVE - - LMUSGROVE@PALMCOASTGOV.COM Elevation page 1 is labeled wrong-should say rear elevation Also a french door is shown on the floor plan but the elev plan shows a Slider? (rear view side) After more discussion with staff, we will approve your original site plan with the driveway dimensions.
SWALE COMPLETE 04/28/2023 06/21/2023
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
BLD COMPLETE 04/27/2023 04/28/2023
Note: Released By: JPI
CUSVC COMPLETE 04/27/2023 05/02/2023
Note: Released By: HALEIGH HAND - -
ELEC HOLD 04/27/2023 05/01/2023
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Need correct outlet spacing NEC 2017 210.52 Master bedroom, bed 3 and bed 2
ENGIN1 COMPLETE 04/27/2023 04/28/2023
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
GAS CANCEL 04/27/2023 04/28/2023
LOCATE COMPLETE 04/27/2023 05/01/2023
Note: Released By: CANDACE STONE - (386)986-2539 - CSTONE@PALMCOASTGOV.COM
MECH HOLD 04/27/2023 04/28/2023
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Provide Duct layout signed by AC contractor per 107.1 FBC Residential 2020 7th Edition
SW1 COMPLETE 04/27/2023 05/04/2023
Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM
ZON HOLD 04/27/2023 04/28/2023
Note: Held By: LIBBY MUSGROVE - - LMUSGROVE@PALMCOASTGOV.COM site plan shows driveway turnaround that is over the max amount of 9'in width. Please correct. Landscape plan missing rear requirements of 4 shrubs facing right of way (golf course) Landscape plan missing 4 requires trees (1 shade , 3 understory) Elevation page 1 is labeled wrong-should say rear elevation. Elevation Plan does not match floor plan
BADMIN COMPLETE 04/27/2023 04/28/2023
Note: Released By: BARBIE BEMBRY - (386)986-3780 - BUILDINGDIVISION@PALMCOASTGOV.COM

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION RESIDENTIAL ¤40.00 03/26/2024
REINSPECTION RESIDENTIAL ¤40.00 03/26/2024
REINSPECTION RESIDENTIAL ¤40.00 03/26/2024
REINSPECTION RESIDENTIAL ¤40.00 03/26/2024
REINSPECTION RESIDENTIAL ¤40.00 03/26/2024
REINSPECTION RESIDENTIAL ¤40.00 03/26/2024
REINSPECTION RESIDENTIAL ¤40.00 03/26/2024
REINSPECTION RESIDENTIAL ¤40.00 03/26/2024
REINSPECTION RESIDENTIAL ¤40.00 03/26/2024
REINSPECTION RESIDENTIAL ¤40.00 03/26/2024
CONTRACTOR CHANGE ¤20.00 03/26/2024
REINSPECTION FEE ¤40.00 03/26/2024
SW ENG REINSPECTION 20 ¤20.00 03/26/2024
SW ENG REINSPECTION 20 ¤20.00 03/26/2024
SW ENG - REVIEW 20 ¤20.00 06/12/2023
SW ENG RES REVIEW 200 ¤200.00 06/12/2023
TRANS IMPACT FEE ADMIN ¤54.36 06/12/2023
TRANS IMPACT FEE ADMIN (¤54.36) 06/12/2023
SEWER CREDIT (¤1,466.00) 06/12/2023
SEWER INSPECTION ¤25.00 06/12/2023
SEWER CAPITAL FACILITY ¤5,344.82 06/12/2023
WATER CAPITAL FACILITY FEE ¤3,923.88 06/12/2023
SITE PLAN 30 ¤30.00 06/12/2023
SURCHARGE FS 533.721 ¤6.40 06/12/2023
SURCHARGE - FS 468.631 ¤9.60 06/12/2023
SW ENG - FOUNDATION SURVEY ¤20.00 06/12/2023
SW ENG INSPECTION 80 ¤80.00 06/12/2023
SW ENG PRE APRON ¤30.00 06/12/2023
WATER- TURN ON ¤25.00 06/12/2023
ADJUSTMENT 50% (¤639.81) 06/12/2023
ADMINISTRATIVE RESIDENTIAL ¤30.00 06/12/2023
INSPECTION - RESIDENTIAL ¤973.50 06/12/2023
PLAN REVIEW - RESIDENTIAL ¤276.12 06/12/2023
FIRE IMPACT FEE ADMIN ¤12.62 06/12/2023
FIRE IMPACT FEE ADMIN (¤12.62) 06/12/2023
FC IMPACT FEE EMS ¤62.00 06/12/2023
IMPACT FEE FIRE ¤420.52 06/12/2023
FC IMPACT FEE LAW ENFORCEMENT ¤218.00 06/12/2023
FC IMPACT FEE LIBRARY ¤268.00 06/12/2023
IMPACT FEE PARKS ¤1,769.15 06/12/2023
IMPACT FEE SCHOOL ¤5,450.00 06/12/2023
IMPACT FEE TRANSPORTATION ¤1,812.00 06/12/2023
WATER -IRRIGATION INSPECTION ¤25.00 06/12/2023
PARKS IMPACT FEE ADMIN ¤53.07 06/12/2023
PARKS IMPACT FEE ADMIN (¤53.07) 06/12/2023
CONNECTION FEES ¤1,166.26 06/12/2023
Fees Total Due: ¤0.00 Total Paid: ¤20,579.44