I want to search for...
Permit #2023041421
Permit Details
Status: COED
| Parcel Id: 07-11-31-7034-01100-0070 |
| CONDITIONED SPACE: 2630 sqft |
| GARAGE: 726 sqft |
| OPENED PORCH (WITH ROOF) : 721 sqft |
| OPENED PORCH (WITH ROOF) : 51 sqft |
| Total Square Footage: 4128 sqft |
| Block: 01100 |
| Subdivision: 2165 - SECTION 34-EASTHAMPTON |
| Job Phone: 386-569-7882 |
| Location Address: 88 ERIC DR |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 06/12/2023 |
| NOC: RECORDED |
| Applicant name: VLADIMIR V PEREPECHKIN |
| Owner: DUMBAULD, CECILLE & JAMES |
|
Address 71 BECKNER LANE PALM COAST, FL 32137 |
| Lot: 0070 |
| Contracted Stated Job Value: ¤350,000.00 |
| Job Description: SINGLE FAMILY RESIDENCE |
| Type: CN |
Contractor
WISE CHOICE CUSTOM HOMES, INC.
| Status | Location Address | State License Number | Phone |
| ACTIVE |
77 SOUTHLAKE DR PALM COAST, FL 32137 |
CRC1328738 (Exp: 08/31/2026) | 386-569-7882 |
Sub Contractors
OLEG BELINSKIY
| Status | Location Address | State License Number | Phone |
| ACTIVE |
19 PINE CIRCLE DRIVE19 PALM COAST, FL 32167 |
CCC1325974 (Exp: 08/31/2026) | 386-263-7906 |
MAXIM BUDNIK
| Status | Location Address | State License Number |
| ACTIVE |
3 WAVECREST PL PALM COAST, FL 32164 |
CAC1818445 (Exp: 08/31/2026) |
MAXIM BUDNIK
| Status | Location Address | State License Number | Phone |
| ACTIVE |
9788 HALSEY RD JACKSONVILLE, FL 32246 |
EC13007415 (Exp: 08/31/2026) | 904-509-7306 |
JUAN CARLOS GONZALEZ
| Status | Location Address | State License Number |
| ACTIVE |
1328 COUNTY ROAD 308 CRESCENT CITY, FL 32112 |
RF11067806 (Exp: 08/31/2027) |
ANDREW GONCALVES HOWARD
| Status | Location Address | State License Number | Phone |
| ACTIVE |
2 RYALL LANE PALM COAST, FL 32164 |
CCC1333989 (Exp: 08/31/2026) | 386-347-0366 |
Inspection History
| Type | Request Date | Result | Inspector |
| BLD - BUILDING FINAL | 03/26/2024 | FINAL APPROVED | RSIMS |
| Note: 3/25/2024 - PREVIOUS INSPECTION NOTES 3-25-24 The following item is still unresolved from the prior lists 10). Bathroom exhaust pipes are still not connected properly to the soffit exhaust termination per FBC-R, M1501.1 3/22/2024 - PREVIOUS INSPECTION NOTES Previously noted items have been resolved. Outlets cannot inside cabinets for kitchen island service 3/21/2024 - PREVIOUS INSPECTION NOTES 3/21/24: Need to fully resolve previous items before Building Final Approval. Previously listed items: 8) hole in garage wall to ceiling is not fully sealed as required. (left side of garage door from inside). 9). Water heater installed after All Rough has now reduced the clear space in front of the Breaker box (as noted previously). 10). Bathroom exhaust pipes are still not connected properly to the soffit exhaust termination. 3/18/2024 - PREVIOUS INSPECTION NOTES 3/18/24: 1). Outside island: Outlet for refigerator is not weather rated as required. 2). Guest bathroom: Tub spout is not sealed at the wall as required. ( FBC-P2705.1(3)). 3). Dishwasher is not plugged in. 4). Garabage disposal is not wired with cord & plug. (new cord laying in bottom of cabinet). 5). MC cable feeding switch for Garbage disposal need to be securely anchored. 6). Garage door safety eyes are over the 6" max from finished floor (UL 325.6 /16CFR part 1211). 7). Interior Garage door missing seal on the right side (from garage). 8). Holes in garage wall & ceiling needs to be sealed with the appropriate material per fire code (FBC302.11). 9). Breaker box still does not have the proper clearance with the water heater in place as required by NEC Section 110.26(A) requires a clear space at least 30 inches wide and 36 inches deep if the equipment is likely to be worked on while energized. 10). Bathroom exhaust pipes are crushed/not installed fully at the soffit vent on the left side of the house. 11). Hole in cinderblock wall at irrigation control wire PVC sleeve needs to be sealed. (right side). 12). Dryer box needs to be sealed around the perimeter where it meets drywall as part of the thermal barrier. 13). Please seal around the service mast pipes where they enter the attic area through the soffit. | |||
| BLD - BUILDING FINAL | 03/25/2024 | Disapproved -FEE REQUIRED | LMILLER |
| Note: 3-25-24 The following item is still unresolved from the prior lists 10). Bathroom exhaust pipes are still not connected properly to the soffit exhaust termination per FBC-R, M1501.1 3/22/2024 - PREVIOUS INSPECTION NOTES Previously noted items have been resolved. Outlets cannot inside cabinets for kitchen island service 3/21/2024 - PREVIOUS INSPECTION NOTES 3/21/24: Need to fully resolve previous items before Building Final Approval. Previously listed items: 8) hole in garage wall to ceiling is not fully sealed as required. (left side of garage door from inside). 9). Water heater installed after All Rough has now reduced the clear space in front of the Breaker box (as noted previously). 10). Bathroom exhaust pipes are still not connected properly to the soffit exhaust termination. 3/18/2024 - PREVIOUS INSPECTION NOTES 3/18/24: 1). Outside island: Outlet for refigerator is not weather rated as required. 2). Guest bathroom: Tub spout is not sealed at the wall as required. ( FBC-P2705.1(3)). 3). Dishwasher is not plugged in. 4). Garabage disposal is not wired with cord & plug. (new cord laying in bottom of cabinet). 5). MC cable feeding switch for Garbage disposal need to be securely anchored. 6). Garage door safety eyes are over the 6" max from finished floor (UL 325.6 /16CFR part 1211). 7). Interior Garage door missing seal on the right side (from garage). 8). Holes in garage wall & ceiling needs to be sealed with the appropriate material per fire code (FBC302.11). 9). Breaker box still does not have the proper clearance with the water heater in place as required by NEC Section 110.26(A) requires a clear space at least 30 inches wide and 36 inches deep if the equipment is likely to be worked on while energized. 10). Bathroom exhaust pipes are crushed/not installed fully at the soffit vent on the left side of the house. 11). Hole in cinderblock wall at irrigation control wire PVC sleeve needs to be sealed. (right side). 12). Dryer box needs to be sealed around the perimeter where it meets drywall as part of the thermal barrier. 13). Please seal around the service mast pipes where they enter the attic area through the soffit. | |||
| BLD - BUILDING FINAL | 03/22/2024 | Disapproved - NO FEE | KSANDOE |
| Note: Previously noted items have been resolved. Outlets cannot inside cabinets for kitchen island service 3/21/2024 - PREVIOUS INSPECTION NOTES 3/21/24: Need to fully resolve previous items before Building Final Approval. Previously listed items: 8) hole in garage wall to ceiling is not fully sealed as required. (left side of garage door from inside). 9). Water heater installed after All Rough has now reduced the clear space in front of the Breaker box (as noted previously). 10). Bathroom exhaust pipes are still not connected properly to the soffit exhaust termination. 3/18/2024 - PREVIOUS INSPECTION NOTES 3/18/24: 1). Outside island: Outlet for refigerator is not weather rated as required. 2). Guest bathroom: Tub spout is not sealed at the wall as required. ( FBC-P2705.1(3)). 3). Dishwasher is not plugged in. 4). Garabage disposal is not wired with cord & plug. (new cord laying in bottom of cabinet). 5). MC cable feeding switch for Garbage disposal need to be securely anchored. 6). Garage door safety eyes are over the 6" max from finished floor (UL 325.6 /16CFR part 1211). 7). Interior Garage door missing seal on the right side (from garage). 8). Holes in garage wall & ceiling needs to be sealed with the appropriate material per fire code (FBC302.11). 9). Breaker box still does not have the proper clearance with the water heater in place as required by NEC Section 110.26(A) requires a clear space at least 30 inches wide and 36 inches deep if the equipment is likely to be worked on while energized. 10). Bathroom exhaust pipes are crushed/not installed fully at the soffit vent on the left side of the house. 11). Hole in cinderblock wall at irrigation control wire PVC sleeve needs to be sealed. (right side). 12). Dryer box needs to be sealed around the perimeter where it meets drywall as part of the thermal barrier. 13). Please seal around the service mast pipes where they enter the attic area through the soffit. | |||
| BLD - BUILDING FINAL | 03/21/2024 | Disapproved - NO FEE | RSIMS |
| Note: 3/21/24: Need to fully resolve previous items before Building Final Approval. Previously listed items: 8) hole in garage wall to ceiling is not fully sealed as required. (left side of garage door from inside). 9). Water heater installed after All Rough has now reduced the clear space in front of the Breaker box (as noted previously). 10). Bathroom exhaust pipes are still not connected properly to the soffit exhaust termination. 3/18/2024 - PREVIOUS INSPECTION NOTES 3/18/24: 1). Outside island: Outlet for refigerator is not weather rated as required. 2). Guest bathroom: Tub spout is not sealed at the wall as required. ( FBC-P2705.1(3)). 3). Dishwasher is not plugged in. 4). Garabage disposal is not wired with cord & plug. (new cord laying in bottom of cabinet). 5). MC cable feeding switch for Garbage disposal need to be securely anchored. 6). Garage door safety eyes are over the 6" max from finished floor (UL 325.6 /16CFR part 1211). 7). Interior Garage door missing seal on the right side (from garage). 8). Holes in garage wall & ceiling needs to be sealed with the appropriate material per fire code (FBC302.11). 9). Breaker box still does not have the proper clearance with the water heater in place as required by NEC Section 110.26(A) requires a clear space at least 30 inches wide and 36 inches deep if the equipment is likely to be worked on while energized. 10). Bathroom exhaust pipes are crushed/not installed fully at the soffit vent on the left side of the house. 11). Hole in cinderblock wall at irrigation control wire PVC sleeve needs to be sealed. (right side). 12). Dryer box needs to be sealed around the perimeter where it meets drywall as part of the thermal barrier. 13). Please seal around the service mast pipes where they enter the attic area through the soffit. | |||
| BLD - BUILDING FINAL | 03/18/2024 | Disapproved -FEE REQUIRED | RSIMS |
| Note: 3/18/24: 1). Outside island: Outlet for refigerator is not weather rated as required. 2). Guest bathroom: Tub spout is not sealed at the wall as required. ( FBC-P2705.1(3)). 3). Dishwasher is not plugged in. 4). Garabage disposal is not wired with cord & plug. (new cord laying in bottom of cabinet). 5). MC cable feeding switch for Garbage disposal need to be securely anchored. 6). Garage door safety eyes are over the 6" max from finished floor (UL 325.6 /16CFR part 1211). 7). Interior Garage door missing seal on the right side (from garage). 8). Holes in garage wall & ceiling needs to be sealed with the appropriate material per fire code (FBC302.11). 9). Breaker box still does not have the proper clearance with the water heater in place as required by NEC Section 110.26(A) requires a clear space at least 30 inches wide and 36 inches deep if the equipment is likely to be worked on while energized. 10). Bathroom exhaust pipes are crushed/not installed fully at the soffit vent on the left side of the house. 11). Hole in cinderblock wall at irrigation control wire PVC sleeve needs to be sealed. (right side). 12). Dryer box needs to be sealed around the perimeter where it meets drywall as part of the thermal barrier. 13). Please seal around the service mast pipes where they enter the attic area through the soffit. | |||
| ROW - STORMWATER FINAL | 03/15/2024 | APPROVED | PFLANAGAN |
| Note: CORRECTIONS MADE -------------------------------------------------------------------------------------- 3/14/2024 - PREVIOUS INSPECTION NOTES STILL NEED TO FIXS THE RUTS AND GRADE ROADSIDE SWALE IN THE VACANT LOT TO THE RIGHT WHEN SODDING ALL SOD NEED TO BE MATCHING GRADE ---------------------------------------------------------------------------------------- 3/8/2024 - PREVIOUS INSPECTION NOTES 3/5/2024 - PREVIOUS INSPECTION NOTES 1) NEED TO REMOVE THE PORTER JOHN FROM THE RIGHT OF WAY 2) ROADSIDE SWALE TO THE RIGHT OF YOUR LOT IN THE VACANT NEEDS TO BE GRADED AND REPAIRED WITH SOD. ALL SOD NEEDS TO MATCH EXISTING GRADE SURROUNDING IT. 3) NEED TO PICK UP ALL TRASH AND CONSTRUCTION DEBRIS FROM VACANT TO THE RIGHT OF YOUR LOT. ---------------------------------------------------------------------------------- 2/23/2024 - PREVIOUS INSPECTION NOTES 2/23/24 PORTA POTTY IS IN THE ROW. NEED TO REMOVE IT AND REPAIR/SOD WHERE IT IS SITTING. THE SWALE ON THE RIGHT SIDE NEEDS TO BE CLEANED UP SOD LAID ON ALL BARE AREAS AND GRADED. THE SOD AT ROAD EDGE IS HIGH, NEEDS TO BE EVEN WITH THE ROAD EDGE AND SLOPED TO MATCH GRADE OF SWALE. YOU HAVE A HIGH SPOT IN THE SWALE HOLDING WATER, THIS NEEDS TO BE CORRECTED TO MATCH GRADE AND ALLOW SWALE TO HAVE POSITIVE DRAINAGE. THIS AREA NEEDS TO BE CLEANED UP, SODDED AND GRADED TO MATCH. SEE PHOTOS FOR REFERENCE. I WILL NOT FEE YOU TODAY AS I WAS HERE FOR AN AFTERPOUR INSPECTION ALREADY. PLEASE MAKE CORRECTIONS BEFORE RESUBMITTING FOR ROW FINAL INSPECTION. Inspector Notes from Inspection 9465 2/22/24 UPON WALKING PROPERTY DETERMINED THAT YOU WILL NEED TO REMOVE/RELOCATE TREE ON THE REAR LEFT PROPERTY CORNER AS IT IS DIRECTLY IN THE DRAINAGE CONVEYANCE OF THE YARD. RIGHT SIDE OUTLINED AREA YOU WILL NEED TO PUT A ROW OF SOD AS WELL TO MAINTAIN THE DRAINAGE CONVEYANCE. I WILL APPROVE THIS FIELD SURVEY AS A COURTESY TO MOVE FORWARD, BUT THESE CORRECTIONS AND ANY OTHER DEEMED NECCESSARY ON SUBSEQUENT INSPECTIONS WILL NEED TO BE MADE BEFORE ROW FINAL PASSAGE. | |||
| ROW - STORMWATER FINAL | 03/14/2024 | Disapproved -FEE REQUIRED | PFLANAGAN |
| Note: STILL NEED TO FIXS THE RUTS AND GRADE ROADSIDE SWALE IN THE VACANT LOT TO THE RIGHT WHEN SODDING ALL SOD NEED TO BE MATCHING GRADE ---------------------------------------------------------------------------------------- 3/8/2024 - PREVIOUS INSPECTION NOTES 3/5/2024 - PREVIOUS INSPECTION NOTES 1) NEED TO REMOVE THE PORTER JOHN FROM THE RIGHT OF WAY 2) ROADSIDE SWALE TO THE RIGHT OF YOUR LOT IN THE VACANT NEEDS TO BE GRADED AND REPAIRED WITH SOD. ALL SOD NEEDS TO MATCH EXISTING GRADE SURROUNDING IT. 3) NEED TO PICK UP ALL TRASH AND CONSTRUCTION DEBRIS FROM VACANT TO THE RIGHT OF YOUR LOT. ---------------------------------------------------------------------------------- 2/23/2024 - PREVIOUS INSPECTION NOTES 2/23/24 PORTA POTTY IS IN THE ROW. NEED TO REMOVE IT AND REPAIR/SOD WHERE IT IS SITTING. THE SWALE ON THE RIGHT SIDE NEEDS TO BE CLEANED UP SOD LAID ON ALL BARE AREAS AND GRADED. THE SOD AT ROAD EDGE IS HIGH, NEEDS TO BE EVEN WITH THE ROAD EDGE AND SLOPED TO MATCH GRADE OF SWALE. YOU HAVE A HIGH SPOT IN THE SWALE HOLDING WATER, THIS NEEDS TO BE CORRECTED TO MATCH GRADE AND ALLOW SWALE TO HAVE POSITIVE DRAINAGE. THIS AREA NEEDS TO BE CLEANED UP, SODDED AND GRADED TO MATCH. SEE PHOTOS FOR REFERENCE. I WILL NOT FEE YOU TODAY AS I WAS HERE FOR AN AFTERPOUR INSPECTION ALREADY. PLEASE MAKE CORRECTIONS BEFORE RESUBMITTING FOR ROW FINAL INSPECTION. Inspector Notes from Inspection 9465 2/22/24 UPON WALKING PROPERTY DETERMINED THAT YOU WILL NEED TO REMOVE/RELOCATE TREE ON THE REAR LEFT PROPERTY CORNER AS IT IS DIRECTLY IN THE DRAINAGE CONVEYANCE OF THE YARD. RIGHT SIDE OUTLINED AREA YOU WILL NEED TO PUT A ROW OF SOD AS WELL TO MAINTAIN THE DRAINAGE CONVEYANCE. I WILL APPROVE THIS FIELD SURVEY AS A COURTESY TO MOVE FORWARD, BUT THESE CORRECTIONS AND ANY OTHER DEEMED NECCESSARY ON SUBSEQUENT INSPECTIONS WILL NEED TO BE MADE BEFORE ROW FINAL PASSAGE. | |||
| ROW - STORMWATER FINAL | 03/08/2024 | CANCELLED BY APPLICANT | EMADISON |
| Note: 3/5/2024 - PREVIOUS INSPECTION NOTES 1) NEED TO REMOVE THE PORTER JOHN FROM THE RIGHT OF WAY 2) ROADSIDE SWALE TO THE RIGHT OF YOUR LOT IN THE VACANT NEEDS TO BE GRADED AND REPAIRED WITH SOD. ALL SOD NEEDS TO MATCH EXISTING GRADE SURROUNDING IT. 3) NEED TO PICK UP ALL TRASH AND CONSTRUCTION DEBRIS FROM VACANT TO THE RIGHT OF YOUR LOT. ---------------------------------------------------------------------------------- 2/23/2024 - PREVIOUS INSPECTION NOTES 2/23/24 PORTA POTTY IS IN THE ROW. NEED TO REMOVE IT AND REPAIR/SOD WHERE IT IS SITTING. THE SWALE ON THE RIGHT SIDE NEEDS TO BE CLEANED UP SOD LAID ON ALL BARE AREAS AND GRADED. THE SOD AT ROAD EDGE IS HIGH, NEEDS TO BE EVEN WITH THE ROAD EDGE AND SLOPED TO MATCH GRADE OF SWALE. YOU HAVE A HIGH SPOT IN THE SWALE HOLDING WATER, THIS NEEDS TO BE CORRECTED TO MATCH GRADE AND ALLOW SWALE TO HAVE POSITIVE DRAINAGE. THIS AREA NEEDS TO BE CLEANED UP, SODDED AND GRADED TO MATCH. SEE PHOTOS FOR REFERENCE. I WILL NOT FEE YOU TODAY AS I WAS HERE FOR AN AFTERPOUR INSPECTION ALREADY. PLEASE MAKE CORRECTIONS BEFORE RESUBMITTING FOR ROW FINAL INSPECTION. Inspector Notes from Inspection 9465 2/22/24 UPON WALKING PROPERTY DETERMINED THAT YOU WILL NEED TO REMOVE/RELOCATE TREE ON THE REAR LEFT PROPERTY CORNER AS IT IS DIRECTLY IN THE DRAINAGE CONVEYANCE OF THE YARD. RIGHT SIDE OUTLINED AREA YOU WILL NEED TO PUT A ROW OF SOD AS WELL TO MAINTAIN THE DRAINAGE CONVEYANCE. I WILL APPROVE THIS FIELD SURVEY AS A COURTESY TO MOVE FORWARD, BUT THESE CORRECTIONS AND ANY OTHER DEEMED NECCESSARY ON SUBSEQUENT INSPECTIONS WILL NEED TO BE MADE BEFORE ROW FINAL PASSAGE. | |||
| ROW - STORMWATER FINAL | 03/05/2024 | Disapproved -FEE REQUIRED | PFLANAGAN |
| Note: 1) NEED TO REMOVE THE PORTER JOHN FROM THE RIGHT OF WAY 2) ROADSIDE SWALE TO THE RIGHT OF YOUR LOT IN THE VACANT NEEDS TO BE GRADED AND REPAIRED WITH SOD. ALL SOD NEEDS TO MATCH EXISTING GRADE SURROUNDING IT. 3) NEED TO PICK UP ALL TRASH AND CONSTRUCTION DEBRIS FROM VACANT TO THE RIGHT OF YOUR LOT. ---------------------------------------------------------------------------------- 2/23/2024 - PREVIOUS INSPECTION NOTES 2/23/24 PORTA POTTY IS IN THE ROW. NEED TO REMOVE IT AND REPAIR/SOD WHERE IT IS SITTING. THE SWALE ON THE RIGHT SIDE NEEDS TO BE CLEANED UP SOD LAID ON ALL BARE AREAS AND GRADED. THE SOD AT ROAD EDGE IS HIGH, NEEDS TO BE EVEN WITH THE ROAD EDGE AND SLOPED TO MATCH GRADE OF SWALE. YOU HAVE A HIGH SPOT IN THE SWALE HOLDING WATER, THIS NEEDS TO BE CORRECTED TO MATCH GRADE AND ALLOW SWALE TO HAVE POSITIVE DRAINAGE. THIS AREA NEEDS TO BE CLEANED UP, SODDED AND GRADED TO MATCH. SEE PHOTOS FOR REFERENCE. I WILL NOT FEE YOU TODAY AS I WAS HERE FOR AN AFTERPOUR INSPECTION ALREADY. PLEASE MAKE CORRECTIONS BEFORE RESUBMITTING FOR ROW FINAL INSPECTION. Inspector Notes from Inspection 9465 2/22/24 UPON WALKING PROPERTY DETERMINED THAT YOU WILL NEED TO REMOVE/RELOCATE TREE ON THE REAR LEFT PROPERTY CORNER AS IT IS DIRECTLY IN THE DRAINAGE CONVEYANCE OF THE YARD. RIGHT SIDE OUTLINED AREA YOU WILL NEED TO PUT A ROW OF SOD AS WELL TO MAINTAIN THE DRAINAGE CONVEYANCE. I WILL APPROVE THIS FIELD SURVEY AS A COURTESY TO MOVE FORWARD, BUT THESE CORRECTIONS AND ANY OTHER DEEMED NECCESSARY ON SUBSEQUENT INSPECTIONS WILL NEED TO BE MADE BEFORE ROW FINAL PASSAGE. | |||
| U -UTILITY RESIDENTIAL FINAL | 03/05/2024 | FINAL APPROVED | JHARDING |
| Note: 2/23/2024 - PREVIOUS INSPECTION NOTES Inspector Notes from Inspection 9035 has potable irrigatin with PVB-no cross connection no power to pep panel/need access to garage-inspect pep breaker | |||
| ELECTRIC - EARLY POWER | 02/26/2024 | APPROVED | RSIMS |
| Note: 2/26/24: FPL emailed to release power. | |||
| U-CROSS CONNECTION | 02/23/2024 | APPROVED - AS NOTED | LFITZGERALD |
| Note: has potable irrigatin with PVB-no cross connection | |||
| ROW - FINAL APRON (AFTER POUR) | 02/23/2024 | APPROVED - AS NOTED | FSLADISH |
| Note: 2/23/24 NOTING PIPE IS 5 HUNDRETHS LOW OOT ON DOWNSTREAM END ON SURVEY. CUTS MADE. CULVERT NEEDS CLEARED ON RIGHT SIDE. HOT PATCH COMPLETED. APPROVING THIS AS NOTED. Inspector Notes from Inspection 9465 2/22/24 UPON WALKING PROPERTY DETERMINED THAT YOU WILL NEED TO REMOVE/RELOCATE TREE ON THE REAR LEFT PROPERTY CORNER AS IT IS DIRECTLY IN THE DRAINAGE CONVEYANCE OF THE YARD. RIGHT SIDE OUTLINED AREA YOU WILL NEED TO PUT A ROW OF SOD AS WELL TO MAINTAIN THE DRAINAGE CONVEYANCE. I WILL APPROVE THIS FIELD SURVEY AS A COURTESY TO MOVE FORWARD, BUT THESE CORRECTIONS AND ANY OTHER DEEMED NECCESSARY ON SUBSEQUENT INSPECTIONS WILL NEED TO BE MADE BEFORE ROW FINAL PASSAGE. | |||
| U -UTILITY RESIDENTIAL FINAL | 02/23/2024 | Disapproved -FEE REQUIRED | LFITZGERALD |
| Note: Inspector Notes from Inspection 9035 has potable irrigatin with PVB-no cross connection no power to pep panel/need access to garage-inspect pep breaker | |||
| ROW - STORMWATER FINAL | 02/23/2024 | Disapproved - NO FEE | FSLADISH |
| Note: 2/23/24 PORTA POTTY IS IN THE ROW. NEED TO REMOVE IT AND REPAIR/SOD WHERE IT IS SITTING. THE SWALE ON THE RIGHT SIDE NEEDS TO BE CLEANED UP SOD LAID ON ALL BARE AREAS AND GRADED. THE SOD AT ROAD EDGE IS HIGH, NEEDS TO BE EVEN WITH THE ROAD EDGE AND SLOPED TO MATCH GRADE OF SWALE. YOU HAVE A HIGH SPOT IN THE SWALE HOLDING WATER, THIS NEEDS TO BE CORRECTED TO MATCH GRADE AND ALLOW SWALE TO HAVE POSITIVE DRAINAGE. THIS AREA NEEDS TO BE CLEANED UP, SODDED AND GRADED TO MATCH. SEE PHOTOS FOR REFERENCE. I WILL NOT FEE YOU TODAY AS I WAS HERE FOR AN AFTERPOUR INSPECTION ALREADY. PLEASE MAKE CORRECTIONS BEFORE RESUBMITTING FOR ROW FINAL INSPECTION. Inspector Notes from Inspection 9465 2/22/24 UPON WALKING PROPERTY DETERMINED THAT YOU WILL NEED TO REMOVE/RELOCATE TREE ON THE REAR LEFT PROPERTY CORNER AS IT IS DIRECTLY IN THE DRAINAGE CONVEYANCE OF THE YARD. RIGHT SIDE OUTLINED AREA YOU WILL NEED TO PUT A ROW OF SOD AS WELL TO MAINTAIN THE DRAINAGE CONVEYANCE. I WILL APPROVE THIS FIELD SURVEY AS A COURTESY TO MOVE FORWARD, BUT THESE CORRECTIONS AND ANY OTHER DEEMED NECCESSARY ON SUBSEQUENT INSPECTIONS WILL NEED TO BE MADE BEFORE ROW FINAL PASSAGE. | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 02/22/2024 | APPROVED | FSLADISH |
| Note: Inspector Notes from Inspection 9270 01/18/24 PLEASE MAKE SURE ALL AREAS ARE PUMPED DRY OF ANY STANDING WATER. YOU MUST MAINTAIN 6" OF CONCRETE FROM EDGE OF ROAD TO ROW THEN 4" MINIMUM FROM THERE BACK. YOU MAY BEED TO RKE OF GRADE THE CENTER OF DRIVEWAY TO KNOCK DOWN ANY HIGH SPOTS. APPROVING AS NOTED AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. | |||
| ROW FIELD SURVEY /GRADING CERTIFICATION | 02/22/2024 | APPROVED - AS NOTED | FSLADISH |
| Note: 2/22/24 UPON WALKING PROPERTY DETERMINED THAT YOU WILL NEED TO REMOVE/RELOCATE TREE ON THE REAR LEFT PROPERTY CORNER AS IT IS DIRECTLY IN THE DRAINAGE CONVEYANCE OF THE YARD. RIGHT SIDE OUTLINED AREA YOU WILL NEED TO PUT A ROW OF SOD AS WELL TO MAINTAIN THE DRAINAGE CONVEYANCE. I WILL APPROVE THIS FIELD SURVEY AS A COURTESY TO MOVE FORWARD, BUT THESE CORRECTIONS AND ANY OTHER DEEMED NECCESSARY ON SUBSEQUENT INSPECTIONS WILL NEED TO BE MADE BEFORE ROW FINAL PASSAGE. | |||
| ROW- PRE-APRON (PRE-POUR) | 01/18/2024 | APPROVED - AS NOTED | TPOLACEK |
| Note: 01/18/24 PLEASE MAKE SURE ALL AREAS ARE PUMPED DRY OF ANY STANDING WATER. YOU MUST MAINTAIN 6" OF CONCRETE FROM EDGE OF ROAD TO ROW THEN 4" MINIMUM FROM THERE BACK. YOU MAY BEED TO RKE OF GRADE THE CENTER OF DRIVEWAY TO KNOCK DOWN ANY HIGH SPOTS. APPROVING AS NOTED AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. | |||
| U - SEWER TIE IN | 01/05/2024 | APPROVED | MGIBSON |
| Note: Inspector Notes from Inspection 2060 PROVIDE PORTABLE RESTROOM BEFORE SCHEDULING MONOLITHIC SLAB INSPECTION | |||
| GRAVITY SEWER TEST | 01/05/2024 | APPROVED | MGIBSON |
| Note: Inspector Notes from Inspection 2060 PROVIDE PORTABLE RESTROOM BEFORE SCHEDULING MONOLITHIC SLAB INSPECTION | |||
| PEP TANK INSTALLATION REQUEST | 12/13/2023 | APPROVED | BVITALE |
| LATH/BRICK/ WATER BARRIER | 11/30/2023 | APPROVED | JWALKER |
| Note: 11/28/2023 - PREVIOUS INSPECTION NOTES 11/28/23: * Wire lath at front entry is still not corrected as required. * Romex wire on right side of the house & holes at lanai kitchen are still not resolved. 11/22/2023 - PREVIOUS INSPECTION NOTES 11/22/23: Previous deficiencies not resolved. Item 1: not resolved. Lath remains vertical. item 2: wire lath needed at all penetrations through block for wires, etc. (tar paper pushed into hole is not an approved process). Holes at back porch area also require wire lath. Item 3: Ufer ground needs to remain accessible with a weather rated cover after stucco is complete.Please remove the wire lath and install a 'Plaster ring' that accepts a blank cover. 11/20/2023 - PREVIOUS INSPECTION NOTES 11/20/23: * Wire lath at left & right walls above the entry is installed vertically. - Wire lath must be installed perpendicular to framing (horizontally) as required by the Manufacturer, The Stucco Institute, The Stucco Manufacturer's Association and ASTM C1063-22. * Missing wire lath at romex on right & low voltage on left side. * Missing plaster ring for Ufer ground on right side. Inspector Notes from Inspection 2420 1. Interior electrical sub panel is to have clear work space of 36" deep by 30" wide. HVAC and Water heater will be in the work space. 2. Rear door and front door not installed . Check for corrections at Insulation inspection. | |||
| INSULATION | 11/30/2023 | APPROVED | JWALKER |
| Note: 11/28/2023 - PREVIOUS INSPECTION NOTES 11/28/23: *Still missing firestop at Horizontal runs. * Electrical Breaker box clearance is still not fully resolved. New inspection due to canceled inspection 11/22/2023 - PREVIOUS INSPECTION NOTES 11/22/23: Previous deficiencies not fully resolved. * Still missing firestop at horizontal runs. * 2"xs added to front entry area need firestop along separations between boards. * Also, modified AHU deck still does not provide the required spacing for the electrical breaker panel as previously noted. 11/20/2023 - PREVIOUS INSPECTION NOTES 11/20/23: Previously listed deficiency is not resolved. * Missing or inadequte firestop in numerous places. Marked with FS on studs below areas. * Blocking above entry between framing and at bathroom pack out wall is under the required thickness for Fire blocking. (1-1/2" minimum). (FBC-R302.11.1) * Missing Firestop at Horizontal wire runs over 10ft. Per FBC 302.11: Required Locations (1.2. Horizontally at intervals not exceeding 10 feet (3048 mm)). (FBC-R302.11/ UL723). * Missing cardboard baffles at all ceiling level changes as required. Inspector Notes from Inspection 2420 1. Interior electrical sub panel is to have clear work space of 36" deep by 30" wide. HVAC and Water heater will be in the work space. 2. Rear door and front door not installed . Check for corrections at Insulation inspection. | |||
| INSULATION | 11/28/2023 | Disapproved -FEE REQUIRED | RSIMS |
| Note: 11/28/23: *Still missing firestop at Horizontal runs. * Electrical Breaker box clearance is still not fully resolved. New inspection due to canceled inspection 11/22/2023 - PREVIOUS INSPECTION NOTES 11/22/23: Previous deficiencies not fully resolved. * Still missing firestop at horizontal runs. * 2"xs added to front entry area need firestop along separations between boards. * Also, modified AHU deck still does not provide the required spacing for the electrical breaker panel as previously noted. 11/20/2023 - PREVIOUS INSPECTION NOTES 11/20/23: Previously listed deficiency is not resolved. * Missing or inadequte firestop in numerous places. Marked with FS on studs below areas. * Blocking above entry between framing and at bathroom pack out wall is under the required thickness for Fire blocking. (1-1/2" minimum). (FBC-R302.11.1) * Missing Firestop at Horizontal wire runs over 10ft. Per FBC 302.11: Required Locations (1.2. Horizontally at intervals not exceeding 10 feet (3048 mm)). (FBC-R302.11/ UL723). * Missing cardboard baffles at all ceiling level changes as required. Inspector Notes from Inspection 2420 1. Interior electrical sub panel is to have clear work space of 36" deep by 30" wide. HVAC and Water heater will be in the work space. 2. Rear door and front door not installed . Check for corrections at Insulation inspection. | |||
| LATH/BRICK/ WATER BARRIER | 11/28/2023 | Disapproved -FEE REQUIRED | RSIMS |
| Note: 11/28/23: * Wire lath at front entry is still not corrected as required. * Romex wire on right side of the house & holes at lanai kitchen are still not resolved. 11/22/2023 - PREVIOUS INSPECTION NOTES 11/22/23: Previous deficiencies not resolved. Item 1: not resolved. Lath remains vertical. item 2: wire lath needed at all penetrations through block for wires, etc. (tar paper pushed into hole is not an approved process). Holes at back porch area also require wire lath. Item 3: Ufer ground needs to remain accessible with a weather rated cover after stucco is complete.Please remove the wire lath and install a 'Plaster ring' that accepts a blank cover. 11/20/2023 - PREVIOUS INSPECTION NOTES 11/20/23: * Wire lath at left & right walls above the entry is installed vertically. - Wire lath must be installed perpendicular to framing (horizontally) as required by the Manufacturer, The Stucco Institute, The Stucco Manufacturer's Association and ASTM C1063-22. * Missing wire lath at romex on right & low voltage on left side. * Missing plaster ring for Ufer ground on right side. Inspector Notes from Inspection 2420 1. Interior electrical sub panel is to have clear work space of 36" deep by 30" wide. HVAC and Water heater will be in the work space. 2. Rear door and front door not installed . Check for corrections at Insulation inspection. | |||
| INSULATION | 11/27/2023 | CANCELLED BY APPLICANT | WEB |
| Note: 11/22/2023 - PREVIOUS INSPECTION NOTES 11/22/23: Previous deficiencies not fully resolved. * Still missing firestop at horizontal runs. * 2"xs added to front entry area need firestop along separations between boards. * Also, modified AHU deck still does not provide the required spacing for the electrical breaker panel as previously noted. 11/20/2023 - PREVIOUS INSPECTION NOTES 11/20/23: Previously listed deficiency is not resolved. * Missing or inadequte firestop in numerous places. Marked with FS on studs below areas. * Blocking above entry between framing and at bathroom pack out wall is under the required thickness for Fire blocking. (1-1/2" minimum). (FBC-R302.11.1) * Missing Firestop at Horizontal wire runs over 10ft. Per FBC 302.11: Required Locations (1.2. Horizontally at intervals not exceeding 10 feet (3048 mm)). (FBC-R302.11/ UL723). * Missing cardboard baffles at all ceiling level changes as required. Inspector Notes from Inspection 2420 1. Interior electrical sub panel is to have clear work space of 36" deep by 30" wide. HVAC and Water heater will be in the work space. 2. Rear door and front door not installed . Check for corrections at Insulation inspection. | |||
| INSULATION | 11/22/2023 | Disapproved -FEE REQUIRED | RSIMS |
| Note: 11/22/23: Previous deficiencies not fully resolved. * Still missing firestop at horizontal runs. * 2"xs added to front entry area need firestop along separations between boards. * Also, the modified AHU deck still does not provide the required spacing for the electrical breaker panel as previously noted. 11/20/2023 - PREVIOUS INSPECTION NOTES 11/20/23: Previously listed deficiency is not resolved. * Missing or inadequte firestop in numerous places. Marked with FS on studs below areas. * Blocking above entry between framing and at bathroom pack out wall is under the required thickness for Fire blocking. (1-1/2" minimum). (FBC-R302.11.1) * Missing Firestop at Horizontal wire runs over 10ft. Per FBC 302.11: Required Locations (1.2. Horizontally at intervals not exceeding 10 feet (3048 mm)). (FBC-R302.11/ UL723). * Missing cardboard baffles at all ceiling level changes as required. Inspector Notes from Inspection 2420 1. Interior electrical sub panel is to have clear work space of 36" deep by 30" wide. HVAC and Water heater will be in the work space. 2. Rear door and front door not installed . Check for corrections at Insulation inspection. | |||
| LATH/BRICK/ WATER BARRIER | 11/22/2023 | Disapproved -FEE REQUIRED | RSIMS |
| Note: 11/22/23: Previous deficiencies not resolved. Item 1: not resolved. Lath remains vertical. item 2: wire lath needed at all penetrations through block for wires, etc. (tar paper pushed into hole is not an approved process). Holes at back porch area also require wire lath. Item 3: Ufer ground needs to remain accessible with a weather rated cover after stucco is complete.Please remove the wire lath and install a 'Plaster ring' that accepts a blank cover. 11/20/2023 - PREVIOUS INSPECTION NOTES 11/20/23: * Wire lath at left & right walls above the entry is installed vertically. - Wire lath must be installed perpendicular to framing (horizontally) as required by the Manufacturer, The Stucco Institute, The Stucco Manufacturer's Association and ASTM C1063-22. * Missing wire lath at romex on right & low voltage on left side. * Missing plaster ring for Ufer ground on right side. Inspector Notes from Inspection 2420 1. Interior electrical sub panel is to have clear work space of 36" deep by 30" wide. HVAC and Water heater will be in the work space. 2. Rear door and front door not installed . Check for corrections at Insulation inspection. | |||
| LATH/BRICK/ WATER BARRIER | 11/20/2023 | Disapproved - NO FEE | RSIMS |
| Note: 11/20/23: * Wire lath at left & right walls above the entry is installed vertically. - Wire lath must be installed perpendicular to framing (horizontally) as required by the Manufacturer, The Stucco Institute, The Stucco Manufacturer's Association and ASTM C1063-22. * Missing wire lath at romex on right & low voltage on left side. * Missing plaster ring for Ufer ground on right side. Inspector Notes from Inspection 2420 1. Interior electrical sub panel is to have clear work space of 36" deep by 30" wide. HVAC and Water heater will be in the work space. 2. Rear door and front door not installed . Check for corrections at Insulation inspection. | |||
| INSULATION | 11/20/2023 | Disapproved -FEE REQUIRED | RSIMS |
| Note: 11/20/23: Previously listed deficiency is not resolved. * Missing or inadequte firestop in numerous places. Marked with FS on studs below areas. * Blocking above entry between framing and at bathroom pack out wall is under the required thickness for Fire blocking. (1-1/2" minimum). (FBC-R302.11.1) * Missing Firestop at Horizontal wire runs over 10ft. Per FBC 302.11: Required Locations (1.2. Horizontally at intervals not exceeding 10 feet (3048 mm)). (FBC-R302.11/ UL723). * Missing cardboard baffles at all ceiling level changes as required. Inspector Notes from Inspection 2420 1. Interior electrical sub panel is to have clear work space of 36" deep by 30" wide. HVAC and Water heater will be in the work space. 2. Rear door and front door not installed . Check for corrections at Insulation inspection. | |||
| ALL ROUGH | 11/13/2023 | APPROVED - AS NOTED | JWALKER |
| Note: 1. Interior electrical sub panel is to have clear work space of 36" deep by 30" wide. HVAC and Water heater will be in the work space. 2. Rear door and front door not installed . Check for corrections at Insulation inspection. | |||
| ROOF VALLEY & METAL | 11/08/2023 | APPROVED | RSIMS |
| Note: Inspector Notes from Inspection 2460 11/7/23: Need dumpster on site & trash cleaned up prior to next inspection. 10/23/2023 - PREVIOUS INSPECTION NOTES 10/23/23: 1). Stud walls are not anchored to CMU walls as required in plan detail. Highlighted. 2). Truss B03 in garage is missing 1 of 2 pieces of engineering as required on MiTek. 3). 2" x 6" in garage load bearing wall that is cut/notched for plumbing will require a revision submitted to & approved by the City for an engineer's letter detailing an approved repair. | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 11/07/2023 | APPROVED - AS NOTED | RSIMS |
| Note: 11/7/23: Need dumpster on site & trash cleaned up prior to next inspection. 10/23/2023 - PREVIOUS INSPECTION NOTES 10/23/23: 1). Stud walls are not anchored to CMU walls as required in plan detail. Highlighted. 2). Truss B03 in garage is missing 1 of 2 pieces of engineering as required on MiTek. 3). 2" x 6" in garage load bearing wall that is cut/notched for plumbing will require a revision submitted to & approved by the City for an engineer's letter detailing an approved repair. | |||
| ROOF VALLEY & METAL | 11/07/2023 | Disapproved -FEE REQUIRED | RSIMS |
| Note: 11/7/23: * Underlayment does not match the nailing pattern per FBC-905.1.1.1(5) (12" / 6"). * 5" x 5" wall flashing is not sealed/anchored properly. Must be sealed to the wall not underlayment & needs to be attached to CMU walls with nails/anchors. | |||
| WALL SHEATHING | 10/23/2023 | APPROVED | RSIMS |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 10/23/2023 | Disapproved -FEE REQUIRED | RSIMS |
| Note: 10/23/23: 1). Stud walls are not anchored to CMU walls as required in plan detail. Highlighted. 2). Truss B03 in garage is missing 1 of 2 pieces of engineering as required on MiTek. 3). 2" x 6" in garage load bearing wall that is cut/notched for plumbing will require a revision submitted to & approved by the City for an engineer's letter detailing an approved repair. | |||
| TIE BEAM / LINTEL | 09/25/2023 | APPROVED | RSIMS |
| FOUND SURVEY APPROVED (OFFICE) | 09/11/2023 | APPROVED | TBAKER |
| MONOLITHIC SLAB | 08/16/2023 | APPROVED | RSIMS |
| Note: 8/14/2023 - PREVIOUS INSPECTION NOTES 8/14/23: Deficiencies marked on print. 1). Back right sleeve for future sink drain line is not fully through the footer. 2). Front two column footers need to be cleaned out to provide proper rebar clearance. 3). Dirt cave in at multiple areas in footers. 8/11/2023 - PREVIOUS INSPECTION NOTES 8/11/23: Inspection Stopped! Incomplete (unbound) prints in Permit box. Missing Page 5 of 7. | |||
| MONOLITHIC SLAB | 08/14/2023 | Disapproved -FEE REQUIRED | RSIMS |
| Note: 8/14/23: Deficiencies marked on print. 1). Back right sleeve for future sink drain line is not fully through the footer. 2). Front two column footers need to be cleaned out to provide proper rebar clearance. 3). Dirt cave in at multiple areas in footers. 8/11/2023 - PREVIOUS INSPECTION NOTES 8/11/23: Inspection Stopped! Incomplete (unbound) prints in Permit box. Missing Page 5 of 7. | |||
| MONOLITHIC SLAB | 08/11/2023 | Disapproved - NO FEE | RSIMS |
| Note: 8/11/23: Inspection Stopped! Incomplete (unbound) prints in Permit box. Missing Page 5 of 7. | |||
| PLUMBING 1ST ROUGH UNDERGROUND | 08/08/2023 | APPROVED - AS NOTED | MGIBSON |
| Note: PROVIDE PORTABLE RESTROOM BEFORE SCHEDULING MONOLITHIC SLAB INSPECTION | |||
| WATER METER INSTALLATION REQUEST | 07/25/2023 | APPROVED | CBOWERMASTER |
Review History
| Department | Status | Date In | Date Out |
| BLD | COMPLETE | 11/02/2023 | 11/06/2023 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 09/11/2023 | 09/11/2023 |
| Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 09/11/2023 | 09/11/2023 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| ZON | HOLD | 09/07/2023 | 09/07/2023 |
| Note: Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM REPEAT COMMENT: Mechanical equipment pad encroaching in platted 5' utility easement. | |||
| ENGIN1 | COMPLETE | 09/07/2023 | 09/08/2023 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 08/28/2023 | 08/29/2023 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| ZON | HOLD | 08/28/2023 | 08/29/2023 |
| Note: Held By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM Mechanical equipment pad encroaching in platted 5' utility easement. | |||
| BLD | COMPLETE | 06/27/2023 | 06/28/2023 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 06/12/2023 | 06/12/2023 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| BLD | HOLD | 06/09/2023 | 06/10/2023 |
| Note: Held By: JPI 1. Per City Truss Submittal Requirements dated April 15, 2023, provide the truss plan packet signed and sealed by a licensed design professional including a completed shop drawing approval stamp on the truss cover sheet. | |||
| BLD | HOLD | 06/07/2023 | 06/08/2023 |
| Note: Held By: JPI 1. Per City Truss Submittal Requirements dated April 15, 2023, provide the truss plan packet signed and sealed by a licensed design professional including a completed shop drawing approval stamp. For ease of review, please label this file Truss Summary- Profiles or Truss Calculations or of a similar nomenclature. 107.3.5 | |||
| ZON | COMPLETE | 05/16/2023 | 05/17/2023 |
| Note: Released By: LIBBY MUSGROVE - - LMUSGROVE@PALMCOASTGOV.COM | |||
| BLD | HOLD | 05/16/2023 | 05/17/2023 |
| Note: Held By: JPI 1. Per City Truss Submittal Requirements dated April 15, 2023, provide the truss plan packet signed and sealed by a licensed design professional. For ease of review, please label this file Truss Summary- Profiles or Truss Calculations or of a similar nomenclature. 107.3.5 | |||
| ELEC | COMPLETE | 05/12/2023 | 05/12/2023 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ZON | HOLD | 05/12/2023 | 05/16/2023 |
| Note: Held By: LIBBY MUSGROVE - - LMUSGROVE@PALMCOASTGOV.COM 2nd request - Elevation page 1 is labeled wrong-should say rear elevation Also a french door is shown on the floor plan but the elev plan shows a Slider? (rear view side) | |||
| MECH | COMPLETE | 05/09/2023 | 05/09/2023 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| ELEC | HOLD | 05/09/2023 | 05/09/2023 |
| Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Need correct outlet spacing NEC 2017 210.52 bed 3 and bed 2 behind doors | |||
| ENGIN1 | COMPLETE | 05/09/2023 | 05/10/2023 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 05/09/2023 | 05/15/2023 |
| Note: Released By: EDWARD MADISON - - EMADISON@PALMCOASTGOV.COM | |||
| ZON | HOLD | 05/09/2023 | 05/12/2023 |
| Note: Held By: LIBBY MUSGROVE - - LMUSGROVE@PALMCOASTGOV.COM Elevation page 1 is labeled wrong-should say rear elevation Also a french door is shown on the floor plan but the elev plan shows a Slider? (rear view side) After more discussion with staff, we will approve your original site plan with the driveway dimensions. | |||
| SWALE | COMPLETE | 04/28/2023 | 06/21/2023 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 04/27/2023 | 04/28/2023 |
| Note: Released By: JPI | |||
| CUSVC | COMPLETE | 04/27/2023 | 05/02/2023 |
| Note: Released By: HALEIGH HAND - - | |||
| ELEC | HOLD | 04/27/2023 | 05/01/2023 |
| Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Need correct outlet spacing NEC 2017 210.52 Master bedroom, bed 3 and bed 2 | |||
| ENGIN1 | COMPLETE | 04/27/2023 | 04/28/2023 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| GAS | CANCEL | 04/27/2023 | 04/28/2023 |
| LOCATE | COMPLETE | 04/27/2023 | 05/01/2023 |
| Note: Released By: CANDACE STONE - (386)986-2539 - CSTONE@PALMCOASTGOV.COM | |||
| MECH | HOLD | 04/27/2023 | 04/28/2023 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Provide Duct layout signed by AC contractor per 107.1 FBC Residential 2020 7th Edition | |||
| SW1 | COMPLETE | 04/27/2023 | 05/04/2023 |
| Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM | |||
| ZON | HOLD | 04/27/2023 | 04/28/2023 |
| Note: Held By: LIBBY MUSGROVE - - LMUSGROVE@PALMCOASTGOV.COM site plan shows driveway turnaround that is over the max amount of 9'in width. Please correct. Landscape plan missing rear requirements of 4 shrubs facing right of way (golf course) Landscape plan missing 4 requires trees (1 shade , 3 understory) Elevation page 1 is labeled wrong-should say rear elevation. Elevation Plan does not match floor plan | |||
| BADMIN | COMPLETE | 04/27/2023 | 04/28/2023 |
| Note: Released By: BARBIE BEMBRY - (386)986-3780 - BUILDINGDIVISION@PALMCOASTGOV.COM |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION RESIDENTIAL | ¤40.00 | 03/26/2024 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 03/26/2024 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 03/26/2024 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 03/26/2024 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 03/26/2024 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 03/26/2024 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 03/26/2024 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 03/26/2024 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 03/26/2024 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 03/26/2024 |
| CONTRACTOR CHANGE | ¤20.00 | 03/26/2024 |
| REINSPECTION FEE | ¤40.00 | 03/26/2024 |
| SW ENG REINSPECTION 20 | ¤20.00 | 03/26/2024 |
| SW ENG REINSPECTION 20 | ¤20.00 | 03/26/2024 |
| SW ENG - REVIEW 20 | ¤20.00 | 06/12/2023 |
| SW ENG RES REVIEW 200 | ¤200.00 | 06/12/2023 |
| TRANS IMPACT FEE ADMIN | ¤54.36 | 06/12/2023 |
| TRANS IMPACT FEE ADMIN | (¤54.36) | 06/12/2023 |
| SEWER CREDIT | (¤1,466.00) | 06/12/2023 |
| SEWER INSPECTION | ¤25.00 | 06/12/2023 |
| SEWER CAPITAL FACILITY | ¤5,344.82 | 06/12/2023 |
| WATER CAPITAL FACILITY FEE | ¤3,923.88 | 06/12/2023 |
| SITE PLAN 30 | ¤30.00 | 06/12/2023 |
| SURCHARGE FS 533.721 | ¤6.40 | 06/12/2023 |
| SURCHARGE - FS 468.631 | ¤9.60 | 06/12/2023 |
| SW ENG - FOUNDATION SURVEY | ¤20.00 | 06/12/2023 |
| SW ENG INSPECTION 80 | ¤80.00 | 06/12/2023 |
| SW ENG PRE APRON | ¤30.00 | 06/12/2023 |
| WATER- TURN ON | ¤25.00 | 06/12/2023 |
| ADJUSTMENT 50% | (¤639.81) | 06/12/2023 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 06/12/2023 |
| INSPECTION - RESIDENTIAL | ¤973.50 | 06/12/2023 |
| PLAN REVIEW - RESIDENTIAL | ¤276.12 | 06/12/2023 |
| FIRE IMPACT FEE ADMIN | ¤12.62 | 06/12/2023 |
| FIRE IMPACT FEE ADMIN | (¤12.62) | 06/12/2023 |
| FC IMPACT FEE EMS | ¤62.00 | 06/12/2023 |
| IMPACT FEE FIRE | ¤420.52 | 06/12/2023 |
| FC IMPACT FEE LAW ENFORCEMENT | ¤218.00 | 06/12/2023 |
| FC IMPACT FEE LIBRARY | ¤268.00 | 06/12/2023 |
| IMPACT FEE PARKS | ¤1,769.15 | 06/12/2023 |
| IMPACT FEE SCHOOL | ¤5,450.00 | 06/12/2023 |
| IMPACT FEE TRANSPORTATION | ¤1,812.00 | 06/12/2023 |
| WATER -IRRIGATION INSPECTION | ¤25.00 | 06/12/2023 |
| PARKS IMPACT FEE ADMIN | ¤53.07 | 06/12/2023 |
| PARKS IMPACT FEE ADMIN | (¤53.07) | 06/12/2023 |
| CONNECTION FEES | ¤1,166.26 | 06/12/2023 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤20,579.44 |