Permit #2023041431

Permit Details

Status: COED

Parcel Id: 07-11-31-7016-00040-0720
CONDITIONED SPACE: 2351 sqft
GARAGE: 544 sqft
SCREEN PORCH (SOLID ROOF) : 530 sqft
OPENED PORCH (WITH ROOF) : 98 sqft
Total Square Footage: 3523 sqft
Block: 00040
Subdivision: 2201 - SECTION 16-COUNTRY CLUB COVE
Job Phone: (386)445-9393
Location Address: 21 CONLEY CT
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 05/10/2023
NOC: RECORDED
Applicant name: ANTONIO JR AMARAL
Owner: THOMPSON BRADLEY D & SALLY P H&W

Address

3328 DUPONT AVE S

MINNEAPOLIS, MN 55408

Lot: 0720
Contracted Stated Job Value: ¤280,000.00
Job Description: SINGLE FAMILY RESIDENCE
Type: CN
Original Permit #: 2021080238

Contractor

AMARAL HOMES & POOLS, LLC
Status Location Address State License Number Phone
ACTIVE

13 Utility Drive

PALM COAST, FL 32137

CBC058062 (Exp: 08/31/2026) (386)445-9393

Sub Contractors

RICHARD H SIMMONS JR
Status Location Address State License Number Phone Fax
ACTIVE

PO BOX 1963

BUNNELL, FL 32110

ES12001217 (Exp: 08/31/2026) 386-437-0607 386-437-1847
JONATHAN M PEARSON
Status Location Address State License Number Phone Fax
ACTIVE

209 N FORSYTH ST

BUNNELL, FL 32110

CFC1425941 (Exp: 08/31/2026) 386-597-0944 386-437-4996
THOMAS A REGULA
Status Location Address State License Number Phone Fax
INACTIVE

11320 PHILLIPS PKWY DRIVE E

JACKSONVILLE, FL 32256

CMC1250075 (Exp: 08/31/2026) 904-278-0339 904-278-0366
ANTONIO AMARAL JR
Status Location Address State License Number
ACTIVE

1370 PALM HARBOR PKWY

PALM COAST, FL 32137

CCC058004 (Exp: 08/31/2026)
RICHARD H SIMMONS JR
Status Location Address State License Number Phone Fax
ACTIVE

PO BOX 1963

BUNNELL, FL 32110

ES12001217 (Exp: 08/31/2026) 386-437-0607 386-437-1847
JONATHAN M PEARSON
Status Location Address State License Number Phone Fax
ACTIVE

209 N FORSYTH ST

BUNNELL, FL 32110

CFC1425941 (Exp: 08/31/2026) 386-597-0944 386-437-4996
ANTONIO AMARAL JR
Status Location Address State License Number
ACTIVE

1370 PALM HARBOR PKWY

PALM COAST, FL 32137

CCC058004 (Exp: 08/31/2026)
GARY LLOYD SHEFFIELD
Status Location Address State License Number Phone
ACTIVE

48 EAGLE LAKES DRIVE

FLAGLER BEACH, FL 32136

CAC048127 (Exp: 08/31/2026) 386-597-3280

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 09/26/2025 FINAL APPROVED HCAMACHO
Note: 9/12/2025 - PREVIOUS INSPECTION NOTES 1. SD/CM detectrors battery back up are not working, keeps beeping.FBCR 314 & 315 2. Outlet in garage is not GFCI protected. Marked with red tape.NEC 210.8 3. Energy Calcs need to be submitted to city for approval.FBC [A] 107.4 4. Missing switch for light on Master bedroom slidder to the lanai.See Plans .NEC 210.70(A)(2)(a) 5. Missing switch and Light outside slidder in bedroom #3. See plans NEC 210.70(A)(2)(a) 6. Receptacle under bar top missing cover plate. NEC 110.27(A)
BLD - BUILDING FINAL 09/12/2025 Disapproved - NO FEE HCAMACHO
Note: 1. SD/CM detectrors battery back up are not working, keeps beeping.FBCR 314 & 315 2. Outlet in garage is not GFCI protected. Marked with red tape.NEC 210.8 3. Energy Calcs need to be submitted to city for approval.FBC [A] 107.4 4. Missing switch for light on Master bedroom slidder to the lanai.See Plans .NEC 210.70(A)(2)(a) 5. Missing switch and Light outside slidder in bedroom #3. See plans NEC 210.70(A)(2)(a) 6. Receptacle under bar top missing cover plate. NEC 110.27(A)
ROW - STORMWATER FINAL 09/11/2025 APPROVED EMADISON
Note: AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED
ROW - STORMWATER FINAL 09/03/2025 CANCELLED BY APPLICANT RRICKS
Note: ** 9/3/25 CANCELED VIA TEXT MESSAGE FROM TONY ARMARAL. 5/21/2025 - PREVIOUS INSPECTION NOTES ** 05/21/25 BUILDER NEEDS TO CUT LAWN IN ORDER FOR INSPECTOR TO SEE IF DRAINAGE WAS CORRECTED ON THE RIGHT SIDE AS NOTED IN PREVIOUS NOTES LEFT BY F. SLADISH 4/30/25 THE INSIDE SWALE NEEDS TO BE .30 FROM THE BOTTOM (TOE) TO THE TOP (SLOPE) TO PREVENT YOUR WATER FROM NEGATIVELY IMPACTING THE ADJACENT PROPERTY ON THE RIGHT SIDE. (***GRASS IS TOO HIGH TO SEE THE DRAINAGE FEATURES***) ** ALONG SEAWALL FILL IN AREAS THAT HAVE SETTLED CREATING GAPS THAT ARE A SAFETY HAZZARD ** YOU WILL ALSO BE REQUIRED TO REMOVE SEDIMENT THAT HAD ERODED INTO THE CANAL AT BOTH THE RIGHT AND LEFT CORNERS. THERE NEEDS TO BE A MINIMUM OF 48 INCHES FROM THE CANAL FLOOR TO THE TOP OF SEAWALL CAP WHEN MEASURED. DRAWING 1100. A SALTWATER CANAL TYPICAL SEAWALL. *****INSPECTORS NOTE. AFTER WALKING PROPERTY DETERMINED YOU WILL NEED TO PUT IN A SWALE AT THE PROPERTY LINE ON THE RIGHT SIDE FENCE LINE AREA ACCORDING TO COPC STANDARDS OF 3 TENTHS FROM TOE TO SLOPE TO KEEP DRAINAGE FROM ADVERSELY IMPACTING NEIGHBOR. THIS WILL BE REQUIRED BEFORE ROW FINAL PASSAGE. YOUR SURVEY SHOWS FLAT AND ONLY ONE TENTH DIFFERENCE IN THIS AREA. ***
U -UTILITY RESIDENTIAL FINAL 05/21/2025 FINAL APPROVED BWRIGHT
ROW - STORMWATER FINAL 05/21/2025 Disapproved - NO FEE EMADISON
Note: ** 05/21/25 BUILDER NEEDS TO CUT LAWN IN ORDER FOR INSPECTOR TO SEE IF DRAINAGE WAS CORRECTED ON THE RIGHT SIDE AS NOTED IN PREVIOUS NOTES LEFT BY F. SLADISH 4/30/25 THE INSIDE SWALE NEEDS TO BE .30 FROM THE BOTTOM (TOE) TO THE TOP (SLOPE) TO PREVENT YOUR WATER FROM NEGATIVELY IMPACTING THE ADJACENT PROPERTY ON THE RIGHT SIDE. (***GRASS IS TOO HIGH TO SEE THE DRAINAGE FEATURES***) ** ALONG SEAWALL FILL IN AREAS THAT HAVE SETTLED CREATING GAPS THAT ARE A SAFETY HAZZARD ** YOU WILL ALSO BE REQUIRED TO REMOVE SEDIMENT THAT HAD ERODED INTO THE CANAL AT BOTH THE RIGHT AND LEFT CORNERS. THERE NEEDS TO BE A MINIMUM OF 48 INCHES FROM THE CANAL FLOOR TO THE TOP OF SEAWALL CAP WHEN MEASURED. DRAWING 1100. A SALTWATER CANAL TYPICAL SEAWALL. *****INSPECTORS NOTE. AFTER WALKING PROPERTY DETERMINED YOU WILL NEED TO PUT IN A SWALE AT THE PROPERTY LINE ON THE RIGHT SIDE FENCE LINE AREA ACCORDING TO COPC STANDARDS OF 3 TENTHS FROM TOE TO SLOPE TO KEEP DRAINAGE FROM ADVERSELY IMPACTING NEIGHBOR. THIS WILL BE REQUIRED BEFORE ROW FINAL PASSAGE. YOUR SURVEY SHOWS FLAT AND ONLY ONE TENTH DIFFERENCE IN THIS AREA. ***
U-CROSS CONNECTION 05/21/2025 APPROVED BWRIGHT
ROW - FINAL APRON (AFTER POUR) 05/21/2025 APPROVED EMADISON
Note: AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED
ELEVATION CERTIFICATE-FINAL APPROVAL 05/16/2025 APPROVED JMYERS
FINAL SURVEY (OFFICE USE ONLY) 04/30/2025 APPROVED FSLADISH
ROW FIELD SURVEY /GRADING CERTIFICATION 04/30/2025 APPROVED FSLADISH
Note: 4/30/25 UPON WALKING PROPERTY DRAINAGE WILL WORK AS INDICATED ON FINAL SURVEY. AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. *****INSPECTORS NOTE. AFTER WALKING PROPERTY DETERMINED YOU WILL NEED TO PUT IN A SWALE AT THE PROPERTY LINE ON THE RIGHT FENCE LINE AREA ACCORDING TO COPC STANDARDS OF 3 TENTHS FROM TOE TO SLOPE TO KEEP DRAINAGE FROM ADVERSELY IMPACTING NEIGHBOR. THIS WILL BE REQUIRED BEFORE ROW FINAL PASSAGE. YOUR SURVEY SHOWS FLAT AND ONLY ONE TENTH DIFFERENCE IN THIS AREA. *** Inspector Notes from Inspection 9270 ** 06/11/24 CORRECTIONS MADE READY TO POUR ** At the time of the inspection all minimum city requirements were met. It is the builders responsibility to ensure that nothing changes after this Inspection is approved. This includes but is not limited to, the Culvert Pipe Elevation from the time of the inspection approval to the concrete pour. **MAKE SURE THERE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL _________________________________________________________________________________________________________________ 6/10/2024 - PREVIOUS INSPECTION NOTES ** 06/10/24 RIGHT SIDE MITERED END FORM BOARDS RUN OUT TOO FLAT NEED TO SLOPE BUILDER NEEDS ** TO REFER TO DRAWING #300.E RESIDENTIAL CONCRETE DRIVEWAY DETAIL SECTION A-A ** NEED TO BACK FILL AROUND FORM BOARDS AT MITERED ENDS TO CONTAIN CONCRETE WITHIN THE POUR AREA AND PREVENT IT FROM POURING OUT INTO THE ROW AS WELL AS IN UPPER DRIVEWAY
ELECTRIC - EARLY POWER 12/05/2024 APPROVED HCAMACHO
ROW- PRE-APRON (PRE-POUR) 06/11/2024 APPROVED - AS NOTED EMADISON
Note: ** 06/11/24 CORRECTIONS MADE READY TO POUR ** At the time of the inspection all minimum city requirements were met. It is the builders responsibility to ensure that nothing changes after this Inspection is approved. This includes but is not limited to, the Culvert Pipe Elevation from the time of the inspection approval to the concrete pour. **MAKE SURE THERE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL _________________________________________________________________________________________________________________ 6/10/2024 - PREVIOUS INSPECTION NOTES ** 06/10/24 RIGHT SIDE MITERED END FORM BOARDS RUN OUT TOO FLAT NEED TO SLOPE BUILDER NEEDS ** TO REFER TO DRAWING #300.E RESIDENTIAL CONCRETE DRIVEWAY DETAIL SECTION A-A ** NEED TO BACK FILL AROUND FORM BOARDS AT MITERED ENDS TO CONTAIN CONCRETE WITHIN THE POUR AREA AND PREVENT IT FROM POURING OUT INTO THE ROW AS WELL AS IN UPPER DRIVEWAY
ROW- PRE-APRON (PRE-POUR) 06/10/2024 Disapproved -FEE REQUIRED EMADISON
Note: ** 06/10/24 RIGHT SIDE MITERED END FORM BOARDS RUN OUT TOO FLAT NEED TO SLOPE BUILDER NEEDS ** TO REFER TO DRAWING #300.E RESIDENTIAL CONCRETE DRIVEWAY DETAIL SECTION A-A ** NEED TO BACK FILL AROUND FORM BOARDS AT MITERED ENDS TO CONTAIN CONCRETE WITHIN THE POUR AREA AND PREVENT IT FROM POURING OUT INTO THE ROW AS WELL AS IN UPPER DRIVEWAY
LATH/BRICK/ WATER BARRIER 04/03/2024 APPROVED FWILLIS
INSULATION 03/21/2024 APPROVED FWILLIS
Note: Inspector Notes from Inspection 2425 Inspector Notes from Inspection 2420 11-28-2023 1. Kitchen vent at roof needs to be sealed properly. 2. Energy calcs and mechanical layout not on site. 3. Entry and lanai door not installed. Fixed glass not installed. Window nailing will be added. 4. Head test failed. Check at next inspection. 03-12-24 1. Kitchen vent at roof needs to be sealed properly. 2. Energy calcs and mechanical layout not on site. 3. Broken glass back left at lanai- note to contractor. Fixed glass not installed at entry. 4. Head test failed. Check at insulation.
WINDOW NAILING 03/12/2024 APPROVED - AS NOTED AGAETANO
Note: Inspector Notes from Inspection 2420 11-28-2023 1. Kitchen vent at roof needs to be sealed properly. 2. Energy calcs and mechanical layout not on site. 3. Entry and lanai door not installed. Fixed glass not installed. Window nailing will be added. 4. Head test failed. Check at next inspection. 03-12-24 1. Kitchen vent at roof needs to be sealed properly. 2. Energy calcs and mechanical layout not on site. 3. Broken glass back left at lanai- note to contractor. Fixed glass not installed at entry. 4. Head test failed. Check at insulation.
ALL ROUGH 11/28/2023 APPROVED - AS NOTED AGAETANO
Note: 11-28-2023 1. Kitchen vent at roof needs to be sealed properly. 2. Energy calcs and mechanical layoiut not on site. 3. Entry and lanai door not installed. Fixed glass not installed. Window nailing will be added. 4. Head test failed. Check at next inspection.
ROOF SHEATHING / BRACES/TIES/DOWN CELL 11/27/2023 APPROVED AGAETANO
Note: 11/8/2023 - PREVIOUS INSPECTION NOTES 10/30/2023 - PREVIOUS INSPECTION NOTES 1-30-23 Second attempt at inspection after call from contractor indicated the plans from the old permit were intered into the new permit with no change of approval, TGhis was confirmed by me). Pland call for straps at truss J 15, There is no J15 in the plans or the engineering docs) REVISION NEEDED PRIOR TO PERFORMING INSPECTION INSPECTION STOPPED 10/30/2023 - PREVIOUS INSPECTION NOTES need approved paperwork/documents on site for inspection FBC 107.3 (need docs for permit # 2023041431)
ROOF VALLEY & METAL 11/27/2023 APPROVED AGAETANO
Note: 11/8/2023 - PREVIOUS INSPECTION NOTES 10/30/2023 - PREVIOUS INSPECTION NOTES need approved paperwork/documents on site for inspection FBC 107.3 (need docs for permit # 2023041431)
ROW - DRAINAGE 11/21/2023 APPROVED - AS NOTED EMADISON
Note: ** 11/21/23 CORRECTIONS MADE AS REQUIRED ** MOVE PORT-A-JOHN FROM EDGE OF ROAD AND PUT ONTO JOB SITE NOT IN THE (ROW SWALE) _____________________________________________________________________________________________________________________ 11/20/2023 - PREVIOUS INSPECTION NOTES AT THE TIME OF THIS INSPECTION THEY ARE WORKING ON THE SILT FENCE STILL NEED TO DO ALL THE FOLLOWING LISTED BELOW. ALSO BUILDER IS RESPONSABLE TO KEEP ROAD SIDE SWALE OPEN THE INTIRE CONSTRUCTION NEXT INSPOECTION ON 11/21/23 -------------------------------------------------------------------------------- 11/16/2023 - PREVIOUS INSPECTION NOTES ** 11/16/23 YOU ARE VIOLATING FDEP REGULATIONS FOR ILLICIT DISCHARGE AND POINT OF CONTACT POLLUTION YOU DISCHARGING SEDIMENT INTO THE CANAL (WATER WAY) ** YOUR EROSION IS ALSO NEGATIVELY IMPACTING BOTH ADJACENT PROPERTIES ** BUILDER NEEDS TO IMMEDIATELY INSTALL SILT FENCING AROUND THE ENTIRE PERIMETER OF THIS JOB SITE THIS INCLUDES ALONG THE FENCE ON THE RIGHT SIDE ** NEED TO REMOVE EXCESS SEDIMENT FROM TOP OF SEAWALL TO SITE ** SPOKE DIRECTLY WITH BUILDER TONY AMARAL Jr. AS A COURTESY FOR CORRECTIVE ACTION REQUIRED BUILDER INDICATED HE WAS NOT REQUIRED TO INSTALL SILT FENCE AROUND ENTIRE SITE I INFORMED HIM THAT AS THE INSPECTOR IT IS BEING REQUIRED. ** SEE ATTACHED PHOTOS ** FOLLOW UP INSPECTION ON 11/20/23
ROW - DRAINAGE 11/20/2023 Disapproved -FEE REQUIRED PFLANAGAN
Note: AT THE TIME OF THIS INSPECTION THEY ARE WORKING ON THE SILT FENCE STILL NEED TO DO ALL THE FOLLOWING LISTED BELOW. ALSO BUILDER IS RESPONSABLE TO KEEP ROAD SIDE SWALE OPEN THE INTIRE CONSTRUCTION NEXT INSPOECTION ON 11/21/23 -------------------------------------------------------------------------------- 11/16/2023 - PREVIOUS INSPECTION NOTES ** 11/16/23 YOU ARE VIOLATING FDEP REGULATIONS FOR ILLICIT DISCHARGE AND POINT OF CONTACT POLLUTION YOU DISCHARGING SEDIMENT INTO THE CANAL (WATER WAY) ** YOUR EROSION IS ALSO NEGATIVELY IMPACTING BOTH ADJACENT PROPERTIES ** BUILDER NEEDS TO IMMEDIATELY INSTALL SILT FENCING AROUND THE ENTIRE PERIMETER OF THIS JOB SITE THIS INCLUDES ALONG THE FENCE ON THE RIGHT SIDE ** NEED TO REMOVE EXCESS SEDIMENT FROM TOP OF SEAWALL TO SITE ** SPOKE DIRECTLY WITH BUILDER TONY AMARAL Jr. AS A COURTESY FOR CORRECTIVE ACTION REQUIRED BUILDER INDICATED HE WAS NOT REQUIRED TO INSTALL SILT FENCE AROUND ENTIRE SITE I INFORMED HIM THAT AS THE INSPECTOR IT IS BEING REQUIRED. ** SEE ATTACHED PHOTOS ** FOLLOW UP INSPECTION ON 11/20/23
ROW - DRAINAGE 11/16/2023 Disapproved -FEE REQUIRED EMADISON
Note: ** 11/16/23 YOU ARE VIOLATING FDEP REGULATIONS FOR ILLICIT DISCHARGE AND POINT OF CONTACT POLLUTION YOU DISCHARGING SEDIMENT INTO THE CANAL (WATER WAY) ** YOUR EROSION IS ALSO NEGATIVELY IMPACTING BOTH ADJACENT PROPERTIES ** BUILDER NEEDS TO IMMEDIATELY INSTALL SILT FENCING AROUND THE ENTIRE PERIMETER OF THIS JOB SITE THIS INCLUDES ALONG THE FENCE ON THE RIGHT SIDE ** NEED TO REMOVE EXCESS SEDIMENT FROM TOP OF SEAWALL TO SITE ** SPOKE DIRECTLY WITH BUILDER TONY AMARAL Jr. AS A COURTESY FOR CORRECTIVE ACTION REQUIRED BUILDER INDICATED HE WAS NOT REQUIRED TO INSTALL SILT FENCE AROUND ENTIRE SITE I INFORMED HIM THAT AS THE INSPECTOR IT IS BEING REQUIRED. ** SEE ATTACHED PHOTOS ** FOLLOW UP INSPECTION ON 11/20/23
ROOF SHEATHING / BRACES/TIES/DOWN CELL 11/08/2023 CANCELLED BY APPLICANT AGAETANO
Note: 10/30/2023 - PREVIOUS INSPECTION NOTES 1-30-23 Second attempt at inspection after call from contractor indicated the plans from the old permit were intered into the new permit with no change of approval, TGhis was confirmed by me). Pland call for straps at truss J 15, There is no J15 in the plans or the engineering docs) REVISION NEEDED PRIOR TO PERFORMING INSPECTION INSPECTION STOPPED 10/30/2023 - PREVIOUS INSPECTION NOTES need approved paperwork/documents on site for inspection FBC 107.3 (need docs for permit # 2023041431)
ROOF VALLEY & METAL 11/08/2023 CANCELLED BY APPLICANT AGAETANO
Note: 10/30/2023 - PREVIOUS INSPECTION NOTES need approved paperwork/documents on site for inspection FBC 107.3 (need docs for permit # 2023041431)
ROOF VALLEY & METAL 10/30/2023 Disapproved - NO FEE LMILLER
Note: need approved paperwork/documents on site for inspection FBC 107.3 (need docs for permit # 2023041431)
ROOF SHEATHING / BRACES/TIES/DOWN CELL 10/30/2023 Disapproved - NO FEE LMILLER
Note: need approved paperwork/documents on site for inspection FBC 107.3 (need docs for permit # 2023041431)
ROOF SHEATHING / BRACES/TIES/DOWN CELL 10/30/2023 Disapproved - NO FEE LMILLER
Note: 1-30-23 Second attempt at inspection after call from contractor indicated the plans from the old permit were intered into the new permit with no change of approval, TGhis was confirmed by me). Pland call for straps at truss J 15, There is no J15 in the plans or the engineering docs) REVISION NEEDED PRIOR TO PERFORMING INSPECTION INSPECTION STOPPED 10/30/2023 - PREVIOUS INSPECTION NOTES need approved paperwork/documents on site for inspection FBC 107.3 (need docs for permit # 2023041431)
ELEV CERT-FOUNDATION APPROVAL 10/27/2023 APPROVED - AS NOTED JMYERS
Note: The Foundation elevation certificate is approved. However, at Final, A9f needs to be N/A as previously noted.
LATH/BRICK/ WATER BARRIER 09/27/2023 CANCELLED BY APPLICANT WEB
WALL SHEATHING 09/18/2023 APPROVED AGAETANO
GRAVITY SEWER TEST 08/11/2023 APPROVED - AS NOTED MGIBSON
Note: THIS WAS A VIRTUAL INSPECTION
U - SEWER TIE IN 08/11/2023 APPROVED - AS NOTED MGIBSON
Note: BOTH 19 AND 21 TAPS MADE
TIE BEAM / LINTEL 08/10/2023 APPROVED AGAETANO
Note: 8/9/2023 - PREVIOUS INSPECTION NOTES 8/3/2023 - PREVIOUS INSPECTION NOTES 8/2/2023 - PREVIOUS INSPECTION NOTES 08/02/2023- Prior Notes not resolved, 7/27/2023 - PREVIOUS INSPECTION NOTES 8/3/23:Per FBC 319.1/501.2 Address needs to be prominently displayed. Clear path to permit box and clean up materials/trash on-site before any more inspections. Also, per Palm Coast code enforcement policy, grass/weeds cannot be higher than 3". Please clean up the site of overgrowth before next inspection. Marked on plans: highlighted in blue Dowel Rebar not exposed and one dowel rebar not installed properly. 7/26/2023 - PREVIOUS INSPECTION NOTES 07-26-2023 Approved drawings not on site. 07-27-2023 Dowels and down rods missed. Noted on drawings.
TIE BEAM / LINTEL 08/09/2023 CANCELLED BY APPLICANT AGAETANO
Note: 8/3/2023 - PREVIOUS INSPECTION NOTES 8/2/2023 - PREVIOUS INSPECTION NOTES 08/02/2023- Prior Notes not resolved, 7/27/2023 - PREVIOUS INSPECTION NOTES 8/3/23:Per FBC 319.1/501.2 Address needs to be prominently displayed. Clear path to permit box and clean up materials/trash on-site before any more inspections. Also, per Palm Coast code enforcement policy, grass/weeds cannot be higher than 3". Please clean up the site of overgrowth before next inspection. Marked on plans: highlighted in blue Dowel Rebar not exposed and one dowel rebar not installed properly. 7/26/2023 - PREVIOUS INSPECTION NOTES 07-26-2023 Approved drawings not on site. 07-27-2023 Dowels and down rods missed. Noted on drawings.
TIE BEAM / LINTEL 08/03/2023 Disapproved -FEE REQUIRED RSIMS
Note: 8/2/2023 - PREVIOUS INSPECTION NOTES 08/02/2023- Prior Notes not resolved, 7/27/2023 - PREVIOUS INSPECTION NOTES 8/3/23:Per FBC 319.1/501.2 Address needs to be prominently displayed. Clear path to permit box and clean up materials/trash on-site before any more inspections. Also, per Palm Coast code enforcement policy, grass/weeds cannot be higher than 3". Please clean up the site of overgrowth before next inspection. Marked on plans: highlighted in blue Dowel Rebar not exposed and one dowel rebar not installed properly. 7/26/2023 - PREVIOUS INSPECTION NOTES 07-26-2023 Approved drawings not on site. 07-27-2023 Dowels and down rods missed. Noted on drawings.
TIE BEAM / LINTEL 08/02/2023 Disapproved -FEE REQUIRED TSTAUFFACHER
Note: 08/02/2023- Prior Notes not resolved, 7/27/2023 - PREVIOUS INSPECTION NOTES 7/26/2023 - PREVIOUS INSPECTION NOTES 07-26-2023 Approved drawings not on site. 07-27-2023 Dowels and down rods missed. Noted on drawings.
TIE BEAM / LINTEL 07/27/2023 Disapproved - NO FEE AGAETANO
Note: 7/26/2023 - PREVIOUS INSPECTION NOTES 07-26-2023 Approved drawings not on site. 07-27-2023 Dowels and down rods missed. Noted on drawings.
TIE BEAM / LINTEL 07/26/2023 Disapproved - NO FEE AGAETANO
Note: 07-26-2023 Approved drawings not on site.
FOUND SURVEY APPROVED (OFFICE) 06/06/2023 APPROVED TBAKER
MONOLITHIC SLAB 05/17/2023 APPROVED TSTAUFFACHER
Note: 5/16/2023 - PREVIOUS INSPECTION NOTES 5/12/2023 - PREVIOUS INSPECTION NOTES THIS IS A REINSPECTION THIS IS A REINSPECTION revision needed, no details in plans for stemwall 06-21-2022 - This is for the house of the stem wall foundation only. Contractor will call in the mono slab when ready. 05-12-2023 1. Compaction test not on site. 2. Head test failed.
MONOLITHIC SLAB 05/16/2023 CANCELLED BY APPLICANT AGAETANO
Note: 5/12/2023 - PREVIOUS INSPECTION NOTES THIS IS A REINSPECTION THIS IS A REINSPECTION revision needed, no details in plans for stemwall 06-21-2022 - This is for the house of the stem wall foundation only. Contractor will call in the mono slab when ready. 05-12-2023 1. Compaction test not on site. 2. Head test failed.
MONOLITHIC SLAB 05/12/2023 Disapproved - NO FEE AGAETANO
Note: THIS IS A REINSPECTION THIS IS A REINSPECTION revision needed, no details in plans for stemwall 06-21-2022 - This is for the house of the stem wall foundation only. Contractor will call in the mono slab when ready. 05-12-2023 1. Compaction test not on site. 2. Head test failed.
PLUMBING 1ST ROUGH UNDERGROUND 05/10/2023 APPROVED MGIBSON
Note: 4/14/2023 - PREVIOUS INSPECTION NOTES JUST STARTED DIGGING ON FIRST ROUGH. NOT READY
PLUMBING 1ST ROUGH UNDERGROUND 04/14/2023 Disapproved -FEE REQUIRED MGIBSON
Note: JUST STARTED DIGGING ON FIRST ROUGH. NOT READY
RETAINING WALL 10/12/2022 APPROVED AGAETANO
MONOLITHIC SLAB 06/21/2022 PARTIALLY APPROVED AGAETANO
Note: THIS IS A REINSPECTION revision needed, no details in plans for stemwall 06-21-2022 - This is for the house of the stem wall foundation only. Contractor will call in the mono slab when ready.
MONOLITHIC SLAB 06/02/2022 Disapproved - NO FEE LMILLER
Note: revision needed, no details in plans for stemwall
WATER METER INSTALLATION REQUEST 11/10/2021 APPROVED CSTONE

Review History

Department Status Date In Date Out
MECH COMPLETE 09/23/2025 09/24/2025
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
PLFM COMPLETE 05/14/2025 05/16/2025
Note: Released By: JORDAN MYERS, C.F.M - (386)986-4789 - JMYERS@PALMCOASTGOV.COM The Final elevation certificate has been approved.
BLD COMPLETE 02/27/2024 03/01/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
PLFM COMPLETE 10/27/2023 10/27/2023
Note: Released By: JORDAN MYERS, C.F.M - (386)986-4789 - JMYERS@PALMCOASTGOV.COM The Foundation elevation certificate is approved. However, at Final, A9f needs to be N/A as previously noted.
PLFM HOLD 10/26/2023 10/27/2023
Note: Held By: JORDAN MYERS, C.F.M - (386)986-4789 - JMYERS@PALMCOASTGOV.COM A9 a-e need to be 0 not N/A per the FEMA instructions, but A9f may remain N/A. B4 please remove the E from the panel as that is listed in B5. B8 please remove the 7' as that is listed in B9. B9 please remove the 'BFE=' as it is unnecessary.
PLFM HOLD 10/09/2023 10/12/2023
Note: Held By: JORDAN MYERS, C.F.M - (386)986-4789 - JMYERS@PALMCOASTGOV.COM A new elevation certificate has been released by FEMA, please revise elevation certificate to be on the new form. B1 is missing the Community Number. C2d is missing measurement box checked. Comments for type of machinery for C2e are missing in Section D.
ENGIN1 COMPLETE 06/05/2023 06/06/2023
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON COMPLETE 06/05/2023 06/05/2023
Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM
PLFM HOLD 06/05/2023 06/05/2023
Note: Held By: JORDAN MYERS, C.F.M - (386)986-2320 - JMYERS@PALMCOASTGOV.COM Construction elevation certificate was not previously submitted, please provide. A7 should be 1B as there is a stem wall shown on plans. B9 should be 7.0'.
BLD COMPLETE 06/16/2022 06/16/2022
Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM
ZON COMPLETE 09/09/2021 09/10/2021
Note: Released By: CINDY CHIRI-GONCALVES - - CGONCALVES@PALMCOASTGOV.COM
ZON HOLD 08/31/2021 09/01/2021
Note: Held By: CINDY CHIRI-GONCALVES - - CGONCALVES@PALMCOASTGOV.COM demonstrate the A/C pad will not be in the 5' utility easement
ENGIN1 COMPLETE 08/31/2021 09/01/2021
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
SW1 COMPLETE 08/31/2021 09/09/2021
Note: Released By: KALEN RUTH - (386)566-1273 - KKRUTH@PALMCOASTGOV.COM
BLD COMPLETE 08/23/2021 08/23/2021
Note: Released By: HAROLD ALLEN - - HALLEN@PALMCOASTGOV.COM
ELEC COMPLETE 08/20/2021 08/20/2021
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
BLD HOLD 08/20/2021 08/20/2021
Note: Held By: HAROLD ALLEN - - HALLEN@PALMCOASTGOV.COM REVIEW COMMENTS: Repeat Comment 1. Truss Layout on sheet 6 notes, Design Code FBC2017. As of January 1, 2021, the Florida State adopted the 2020 7th edition. A revision is required to reflect the current Code. Sheet 6 was not revised. 2. A revision is required for the Product Approvals submitted. Various approvals are not current. FBCR107
ZON HOLD 08/20/2021 08/20/2021
Note: Held By: CINDY CHIRI-GONCALVES - - CGONCALVES@PALMCOASTGOV.COM site plan and landscape plan do not match. Please include the proposed pool in your site plan. please correct survey and site plan flood map number: (missing flood zone map numerber to include AE and X 0.2 PCT ANNUAL CHANCE FLOOD HAZARD. ) must be included in the surveyers notes on line 5.
BLD HOLD 08/05/2021 08/06/2021
Note: Held By: HAROLD ALLEN - - HALLEN@PALMCOASTGOV.COM REVIEW COMMENTS: 1. Truss Layout on sheet 6 notes, Design Code FBC2017. As of January 1, 2021, the Florida State adopted the 2020 7th edition. A revision is required to reflect the current Code. 2. A revision is required for the Product Approvals submitted. Various approvals are not current. FBCR107
CUSVC COMPLETE 08/05/2021 08/11/2021
Note: Released By: HALEIGH HAND - -
ELEC HOLD 08/05/2021 08/06/2021
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM Need light and switch by exterior door in bedroom 3 and need switch in master bedroom for outside lights by exterior door. NEC 2017 210.70
ENGIN1 COMPLETE 08/05/2021 08/05/2021
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
LOCATE COMPLETE 08/05/2021 08/06/2021
Note: Released By: CANDACE STONE - - CSTONE@PALMCOASTGOV.COM
MECH COMPLETE 08/05/2021 08/10/2021
Note: Released By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM
SW1 COMPLETE 08/05/2021 08/12/2021
Note: Released By: KALEN RUTH - (386)566-1273 - KKRUTH@PALMCOASTGOV.COM
ZON HOLD 08/05/2021 08/06/2021
Note: Held By: CINDY CHIRI-GONCALVES - - CGONCALVES@PALMCOASTGOV.COM Demonstrate on landscape plan that the 3 trees in the rear of home will not be planted on the 5' utility easement. demonstrate the A/C pad will not be in the 5' utility easement site plan and landscape plan do not match. Please include the proposed pool. please correct survey and site plan flood map number: (missing flood zone map numerber to include AE and X 0.2 PCT ANNUAL CHANCE FLOOD HAZARD. )
SWALE COMPLETE 08/05/2021 11/04/2021
Note: Released By: JOHN HOWARD - - JHOWARD@PALMCOASTGOV.COM

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION RESIDENTIAL ¤40.00 09/27/2025
REINSPECTION RESIDENTIAL ¤40.00 09/27/2025
CONTRACTOR CHANGE ¤20.00 09/27/2025
PLAN REVIEW - REVISION ¤32.50 09/27/2025
SW ENG - INSPECTION 20 ¤20.00 09/27/2025
SW ENG REINSPECTION 30 ¤30.00 09/27/2025
SW ENG - REVIEW 20 ¤20.00 05/10/2023
SW ENG RES REVIEW 200 ¤200.00 05/10/2023
SW ENG INSPECTION 80 ¤80.00 05/10/2023
SW ENG PRE APRON ¤30.00 05/10/2023
REINSPECTION RESIDENTIAL ¤40.00 05/10/2023
SURCHARGE FS 533.721 ¤4.51 05/10/2023
SURCHARGE - FS 468.631 ¤6.77 05/10/2023
SW ENG - FOUNDATION SURVEY ¤20.00 05/10/2023
ADJUSTMENT 50% (¤439.88) 05/10/2023
ADMINISTRATIVE RESIDENTIAL ¤30.00 05/10/2023
EXTENSION ¤40.00 05/10/2023
INSPECTION - RESIDENTIAL ¤849.75 05/10/2023
PLAN REVIEW - REVISION ¤32.50 05/10/2023
Fees Total Due: ¤0.00 Total Paid: ¤1,096.15