I want to search for...
Permit #2023050099
Permit Details
Status: FINAL
| Parcel Id: 07-11-31-7026-00490-0180 |
| Block: 00490 |
| Subdivision: 2153 - SECTION 26-PINE GROVE |
| Job Phone: 732-421-5880 |
| Location Address: 35 PIERCE LN |
| Type: DR - DRIVEWAY |
| Issue Date: 05/18/2023 |
| NOC: Unknown |
| Applicant name: CLAUDIO MIGUEL SARAIVA |
| Owner: ALVES ANTONIO & TINA H&W LIFE ESTATE |
|
Address 35 PIERCE LANE PALM COAST, FL 32164 |
| Lot: 0180 |
| Contracted Stated Job Value: ¤2,450.00 |
| Job Description: 21FT CONCRETE DRIVEWAY |
| Type: CN |
Contractor
CMS CONSTRUCTION LLC
| Status | Location Address | Phone |
| INACTIVE |
19 BRADDOCK LN PALM COAST, FL 32137 |
732-421-5880 |
Inspection History
| Type | Request Date | Result | Inspector |
| U -UTILITY RESIDENTIAL FINAL | 06/27/2023 | FINAL APPROVED | LFITZGERALD |
| ROW - FINAL APRON (AFTER POUR) | 06/26/2023 | APPROVED | FSLADISH |
| Note: 06/26/23 PIPE ELAVATION IS GOOD. CULVERT CLEAR. LOOKED GOOD AT TIME OF INSPECTION. ______________________________________________________________________________________________________________________ nspector Notes from Inspection 9270 05/25/23 CORRECTIONS MADE. 5" MINIMUM OVER BOTH PIPE ENDS. NEED TO DIG OUT RIGHT SIDE MITER FOOTER ABOUT 1" TO HAVE THE REQUIRED 6" X 6" MINIMUM FOOTER REQUIREMENT. READY TO POUR. AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS BEFORE POURING. MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL _______________________________________________________________________________________________________________________ 5/19/2023 - PREVIOUS INSPECTION NOTES 05/19/23= The culvert cannot be sloped against the drainage flow I NEED 5 INCH THE CONCRETE MINIMUM ON TOP OF THE CULVERT PIPE AND 2 INCH MINIMUM ON THE MITER ENDS | |||
| ROW - FINAL INSPECTION | 06/26/2023 | APPROVED | FSLADISH |
| Note: 06/26/23 EVERYTHING LOOKED GOOD AT TIME OF INSPECTION. _____________________________________________________________________________________________________________________ Inspector Notes from Inspection 9270 05/25/23 CORRECTIONS MADE. 5" MINIMUM OVER BOTH PIPE ENDS. NEED TO DIG OUT RIGHT SIDE MITER FOOTER ABOUT 1" TO HAVE THE REQUIRED 6" X 6" MINIMUM FOOTER REQUIREMENT. READY TO POUR. AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS BEFORE POURING. MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL _______________________________________________________________________________________________________________________ 5/19/2023 - PREVIOUS INSPECTION NOTES 05/19/23= The culvert cannot be sloped against the drainage flow I NEED 5 INCH THE CONCRETE MINIMUM ON TOP OF THE CULVERT PIPE AND 2 INCH MINIMUM ON THE MITER ENDS | |||
| ROW- PRE-APRON (PRE-POUR) | 05/25/2023 | APPROVED - AS NOTED | FSLADISH |
| Note: 05/25/23 CORRECTIONS MADE. 5" MINIMUM OVER BOTH PIPE ENDS. NEED TO DIG OUT RIGHT SIDE MITER FOOTER ABOUT 1" TO HAVE THE REQUIRED 6" X 6" MINIMUM FOOTER REQUIREMENT. READY TO POUR. AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS BEFORE POURING. MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL _______________________________________________________________________________________________________________________ 5/19/2023 - PREVIOUS INSPECTION NOTES 05/19/23= The culvert cannot be sloped against the drainage flow I NEED 5 INCH THE CONCRETE MINIMUM ON TOP OF THE CULVERT PIPE AND 2 INCH MINIMUM ON THE MITER ENDS | |||
| ROW- PRE-APRON (PRE-POUR) | 05/19/2023 | Disapproved -FEE REQUIRED | GBERTOLA |
| Note: 05/19/23= The culvert cannot be sloped against the drainage flow I NEED 5 INCH THE CONCRETE MINIMUM ON TOP OF THE CULVERT PIPE AND 2 INCH MINIMUM ON THE MITER ENDS |
Review History
| Department | Status | Date In | Date Out |
| ENGIN1 | COMPLETE | 05/02/2023 | 05/04/2023 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| UTL | COMPLETE | 05/02/2023 | 05/08/2023 |
| Note: Released By: LARRY FITZGERALD - (386)286-2041 - LFITZGERALD@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 05/02/2023 | 05/02/2023 |
| Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| SW ENG REINSPECTION 30 | ¤30.00 | 06/26/2023 |
| SW ENG RES REVIEW 200 | ¤200.00 | 05/18/2023 |
| SITE PLAN 15 | ¤15.00 | 05/18/2023 |
| ADJUSTMENT 50% | (¤15.00) | 05/18/2023 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 05/18/2023 |
| SW ENG INSPECTION 40 | ¤40.00 | 05/18/2023 |
| SW ENG PRE APRON | ¤30.00 | 05/18/2023 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤330.00 |