Permit #2023050252

Permit Details

Status: COED

Parcel Id: 07-11-31-7011-00010-1630
CONDITIONED SPACE: 2303 sqft
GARAGE: 726 sqft
SCREEN PORCH (SOLID ROOF) : 665 sqft
OPENED PORCH (WITH ROOF) : 59 sqft
Total Square Footage: 3753 sqft
Block: 00010
Subdivision: 2193 - SECTION 11-BELLE TERRE
Job Phone: 386-237-8427
Location Address: 188 BEACHWAY DR
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 05/23/2023
NOC: RECORDED
Applicant name: JAY DARREN CURBOW
Owner: CRAWFORD DAVID S & NADEZHDA K H&W

Address

18 WHITTLESEY LN

PALM COAST, FL 32164

Lot: 1630
Contracted Stated Job Value: ¤390,913.00
Job Description: Single Family Residence
Type: CN

Contractor

BLUE WATER HOMES INC
Status Location Address State License Number Phone
ACTIVE

4881 PALM COAST PARKWAY NW UNIT 1

PALM COAST, FL 32137

CBC1258679 (Exp: 08/31/2026) 386-445-3405

Sub Contractors

JACK DOUGLAS LANIER
Status Location Address State License Number Phone Fax
ACTIVE

485 COMMERCE WAY

LONGWOOD , FL 32750

CCC058022 (Exp: 08/31/2026) (321)441-2300 (321)441-2313
WILLIAM FRANK DUDLEY JR.
Status Location Address State License Number Phone
ACTIVE

P.O. BOX 978

Bunnell, FL 32110

EC0003177 (Exp: 08/31/2026) (386)437-3068
BRETT CHRISTIAN GIBSON
Status Location Address State License Number Phone
ACTIVE

250 SEGOVIA RD

ST AUGUSTINE, FL 32086

CAC1818423 (Exp: 08/31/2026) 904-229-8131
JEFFREY TROY SABAKA
Status Location Address State License Number Phone Fax
ACTIVE

2191 DEERWOOD ACRES DR

ST AUGUSTINE, FL 32084

CFC1427439 (Exp: 08/31/2026) 904-838-2218 904-819-0965

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 03/14/2024 FINAL APPROVED JSTEWART
U-CROSS CONNECTION 02/29/2024 APPROVED DHANEY
ROW - FINAL APRON (AFTER POUR) 02/29/2024 APPROVED TPOLACEK
Note: 02/29/24 PIPE IS GOOD, CUTS ARE MADE, CULVERT CLEAR, HOT PATCH COMPLETE. AT THE TIME FROM THE TIME OF THE INSPECTION OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. Inspector Notes from Inspection 9465 02/27/24 AT THE TIME FROM THE TIME OF THE INSPECTION OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. ** INSPECTOR NOTE ROADSIDE SWALE ACROSS THE STREET STILL NEEDS IMPROVEMENTS. THERE ARE LARGE RUTS FROM TIRES THAT NEED TO BE CORRECTED.
ROW - DRAINAGE 02/29/2024 APPROVED TPOLACEK
Note: 02/29/24 CORRECTION WERE MADE AT THE TIME FROM THE TIME OF THE INSPECTION OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED Inspector Notes from Inspection 9471 02/29/24 THERE IS STILL WORK BEING DONE AND THERE IS A SMALL AMOUNT OF TRASH AND CONCTRUCTION DEBRIS AROUND PROPERTY THAT NEEDS TO BE CLEANED UP. WILL APPROVE AS NOTED. SWALE ACROSS THE STREET HAS BEEN REPAIRED AND I WILL ALSO CLEAR THE DRAINAGE INSPECTION AS WELL. PLEASE MAKE SURE TO CLEAN UP ALL TRASH. Inspector Notes from Inspection 9465 02/27/24 AT THE TIME FROM THE TIME OF THE INSPECTION OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. ** INSPECTOR NOTE ROADSIDE SWALE ACROSS THE STREET STILL NEEDS IMPROVEMENTS. THERE ARE LARGE RUTS FROM TIRES THAT NEED TO BE CORRECTED. 11/17/2023 - PREVIOUS INSPECTION NOTES STILL NEED TO DO ALL THE FOLLOWING LISTED IN LAST INSPECTION WE WILL BE BACK ON MONDAY 11/20/23 IF ALL OF THE FOLLOWING IS NOT DONE THERE WILL BE AN INSPECTION HOLD ON THIS CONSTRUCTION SITE THIS IS AN ON GOING ISSUE WITH THIS SITE SINCE JULY 23. -------------------------------------------------------------------------------------------- 11/15/2023 - PREVIOUS INSPECTION NOTES ** 11/15/23 THE BUILDER WAS INFORMED THAT THEY MUST MAINTAIN THE ROAD SIDE SWALE FOR DRAINAGE AFTER PREVIOUS DRAINAGE INSPECTIONS, AND HAVE FAILED TO COMPLY YOU ARE NEGATIVELY IMPACTING THE ADJACENT PROPERTIES. ** FOLLOW UP INSPECTIONS WILL BE CONDUCTED UNTIL THE BUILDER TAKES CORRECTIVE ACTION ** BUILDER NEEDS TO OPEN ROAD SIDE SWALE RECOMEND THE INSTALLATION OF A TEMPORARY CULVERT TO MIMIMUM OF 12 INCHES IN DIAMETER TO ALLOW FOR THE FLOW OF STORMWATER. ** MUST SET TEMPORARY CULVERT TO MATCH EXISTING GRADE NOT HIGHER THAN. *** TEMPORARY PIPE YOU CURRENTLY HAVE IN PLACE IS NOT APPROPRIATE AS ITS NOT LONG ENOUGH AND CAN NOT BE TAPED TOGETHER *** ** BUILDER NEEDS TO RE-ESTABLISH SILT FENCE AROUND ENTIRE JOB SITE ** SEE ATTACHED PHOTOS ** FOLLOW UP INSPECTION ON 11/17/23 __________________________________________________________________________________________________________________ Inspector Notes from Inspection 9470 ** 08/07/23 IT IS THE BUILDERS RESPONSIBILITY TO MAINTAIN THE ROAD SIDE SWALE ON A DAILY BASIS ** TEMPORARY CULVERT IS MORE THAN 50% FULL OF SEDIMENT BUILDER NEEDS TO BE AWARE AND CLEAN OUT IF THE FLOW OF STORMWATER IS IMPEDED BY THIS ____________________________________________________________________________________________________________________ 8/1/2023 - PREVIOUS INSPECTION NOTES STILL NEED TO CLEAR SWALE SO WATER CAN FLOW THROUGH THE LOT TO OUTFALL OR PUT A TEMPORARY CULVERT SO WATER CAN FLOW NEED TO REMOVE THE PORTA JOHN OUT OF SWALE TRUSSES ARE MOVE AT THIS TIME ------------------------------------------------------------------------------------ 7/31/2023 - PREVIOUS INSPECTION NOTES ** 07/31/23 BUILDER NEEDS TO REMOVE YOUR TRUSSES FROM THE ROADWAY IMMEDIATELY YOU ARE CREATING A SAFETY HAZARD FOR PEDESTRIANS, BICYCLISTS, AND MOTORIST ** BUILDER NEEDS TO REMOVE TRUSSES, PORT-A-JOHN AND CONSTRUCTION DEBRIS FROM THE ROAD SIDE SWALE IMMEDIATELY YOU ARE CREATING A SAFETY HAZARD FOR PEDESTRIANS, BICYCLISTS, AND MOTORISTS ** HUURICANE SEASON IS UPON YOU NEED TO MAINTAIN THE ROAD SIDE SWALE ON A DAILY BASIS OR INSTALL A TEMPORARY CULVERT. ** SEE ATTACHED PHOTOS
ROW - STORMWATER FINAL 02/29/2024 APPROVED - AS NOTED TPOLACEK
Note: 02/29/24 THERE IS STILL WORK BEING DONE AND THERE IS A SMALL AMOUNT OF TRASH AND CONCTRUCTION DEBRIS AROUND PROPERTY THAT NEEDS TO BE CLEANED UP. WILL APPROVE AS NOTED. SWALE ACROSS THE STREET HAS BEEN REPAIRED AND I WILL ALSO CLEAR THE DRAINAGE INSPECTION AS WELL. PLEASE MAKE SURE TO CLEAN UP ALL TRASH. Inspector Notes from Inspection 9465 02/27/24 AT THE TIME FROM THE TIME OF THE INSPECTION OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. ** INSPECTOR NOTE ROADSIDE SWALE ACROSS THE STREET STILL NEEDS IMPROVEMENTS. THERE ARE LARGE RUTS FROM TIRES THAT NEED TO BE CORRECTED.
U -UTILITY RESIDENTIAL FINAL 02/29/2024 FINAL APPROVED DHANEY
ROW- FINAL SURVEY/GRADING CERTIFICATION 02/27/2024 APPROVED TPOLACEK
Note: 02/27/24 AT THE TIME FROM THE TIME OF THE INSPECTION OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. Inspector Notes from Inspection 9270 01/23/24 AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. INSPECTOR NOTE: ROADSIDE SWALE ACROSS THE STREET IN FRONT OF THE VACANT WILL NEED TO BE REPAIRED
ROW FIELD SURVEY /GRADING CERTIFICATION 02/27/2024 APPROVED - AS NOTED TPOLACEK
Note: 02/27/24 AT THE TIME FROM THE TIME OF THE INSPECTION OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. ** INSPECTOR NOTE ROADSIDE SWALE ACROSS THE STREET STILL NEEDS IMPROVEMENTS. THERE ARE LARGE RUTS FROM TIRES THAT NEED TO BE CORRECTED.
ROW- PRE-APRON (PRE-POUR) 01/23/2024 APPROVED - AS NOTED TPOLACEK
Note: 01/23/24 AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. INSPECTOR NOTE: ROADSIDE SWALE ACROSS THE STREET IN FRONT OF THE VACANT WILL NEED TO BE REPAIRED
U - SEWER TIE IN 12/06/2023 APPROVED - AS NOTED MGIBSON
Note: THISB WAS A VIRTUAL INSPECTION
TUB SET 12/05/2023 APPROVED JSTEWART
ELECTRIC - EARLY POWER 11/30/2023 APPROVED - AS NOTED JSTEWART
Note: 11/30/23- Authorize release of email to FPL @ 10:37a.
ROW - DRAINAGE 11/17/2023 Disapproved -FEE REQUIRED PFLANAGAN
Note: STILL NEED TO DO ALL THE FOLLOWING LISTED IN LAST INSPECTION WE WILL BE BACK ON MONDAY 11/20/23 IF ALL OF THE FOLLOWING IS NOT DONE THERE WILL BE AN INSPECTION HOLD ON THIS CONSTRUCTION SITE THIS IS AN ON GOING ISSUE WITH THIS SITE SINCE JULY 23. -------------------------------------------------------------------------------------------- 11/15/2023 - PREVIOUS INSPECTION NOTES ** 11/15/23 THE BUILDER WAS INFORMED THAT THEY MUST MAINTAIN THE ROAD SIDE SWALE FOR DRAINAGE AFTER PREVIOUS DRAINAGE INSPECTIONS, AND HAVE FAILED TO COMPLY YOU ARE NEGATIVELY IMPACTING THE ADJACENT PROPERTIES. ** FOLLOW UP INSPECTIONS WILL BE CONDUCTED UNTIL THE BUILDER TAKES CORRECTIVE ACTION ** BUILDER NEEDS TO OPEN ROAD SIDE SWALE RECOMEND THE INSTALLATION OF A TEMPORARY CULVERT TO MIMIMUM OF 12 INCHES IN DIAMETER TO ALLOW FOR THE FLOW OF STORMWATER. ** MUST SET TEMPORARY CULVERT TO MATCH EXISTING GRADE NOT HIGHER THAN. *** TEMPORARY PIPE YOU CURRENTLY HAVE IN PLACE IS NOT APPROPRIATE AS ITS NOT LONG ENOUGH AND CAN NOT BE TAPED TOGETHER *** ** BUILDER NEEDS TO RE-ESTABLISH SILT FENCE AROUND ENTIRE JOB SITE ** SEE ATTACHED PHOTOS ** FOLLOW UP INSPECTION ON 11/17/23 __________________________________________________________________________________________________________________ Inspector Notes from Inspection 9470 ** 08/07/23 IT IS THE BUILDERS RESPONSIBILITY TO MAINTAIN THE ROAD SIDE SWALE ON A DAILY BASIS ** TEMPORARY CULVERT IS MORE THAN 50% FULL OF SEDIMENT BUILDER NEEDS TO BE AWARE AND CLEAN OUT IF THE FLOW OF STORMWATER IS IMPEDED BY THIS ____________________________________________________________________________________________________________________ 8/1/2023 - PREVIOUS INSPECTION NOTES STILL NEED TO CLEAR SWALE SO WATER CAN FLOW THROUGH THE LOT TO OUTFALL OR PUT A TEMPORARY CULVERT SO WATER CAN FLOW NEED TO REMOVE THE PORTA JOHN OUT OF SWALE TRUSSES ARE MOVE AT THIS TIME ------------------------------------------------------------------------------------ 7/31/2023 - PREVIOUS INSPECTION NOTES ** 07/31/23 BUILDER NEEDS TO REMOVE YOUR TRUSSES FROM THE ROADWAY IMMEDIATELY YOU ARE CREATING A SAFETY HAZARD FOR PEDESTRIANS, BICYCLISTS, AND MOTORIST ** BUILDER NEEDS TO REMOVE TRUSSES, PORT-A-JOHN AND CONSTRUCTION DEBRIS FROM THE ROAD SIDE SWALE IMMEDIATELY YOU ARE CREATING A SAFETY HAZARD FOR PEDESTRIANS, BICYCLISTS, AND MOTORISTS ** HUURICANE SEASON IS UPON YOU NEED TO MAINTAIN THE ROAD SIDE SWALE ON A DAILY BASIS OR INSTALL A TEMPORARY CULVERT. ** SEE ATTACHED PHOTOS
ROW - DRAINAGE 11/15/2023 Disapproved -FEE REQUIRED EMADISON
Note: ** 11/15/23 THE BUILDER WAS INFORMED THAT THEY MUST MAINTAIN THE ROAD SIDE SWALE FOR DRAINAGE AFTER PREVIOUS DRAINAGE INSPECTIONS, AND HAVE FAILED TO COMPLY YOU ARE NEGATIVELY IMPACTING THE ADJACENT PROPERTIES. ** FOLLOW UP INSPECTIONS WILL BE CONDUCTED UNTIL THE BUILDER TAKES CORRECTIVE ACTION ** BUILDER NEEDS TO OPEN ROAD SIDE SWALE RECOMEND THE INSTALLATION OF A TEMPORARY CULVERT TO MIMIMUM OF 12 INCHES IN DIAMETER TO ALLOW FOR THE FLOW OF STORMWATER. ** MUST SET TEMPORARY CULVERT TO MATCH EXISTING GRADE NOT HIGHER THAN. *** TEMPORARY PIPE YOU CURRENTLY HAVE IN PLACE IS NOT APPROPRIATE AS ITS NOT LONG ENOUGH AND CAN NOT BE TAPED TOGETHER *** ** BUILDER NEEDS TO RE-ESTABLISH SILT FENCE AROUND ENTIRE JOB SITE ** SEE ATTACHED PHOTOS ** FOLLOW UP INSPECTION ON 11/17/23 __________________________________________________________________________________________________________________ Inspector Notes from Inspection 9470 ** 08/07/23 IT IS THE BUILDERS RESPONSIBILITY TO MAINTAIN THE ROAD SIDE SWALE ON A DAILY BASIS ** TEMPORARY CULVERT IS MORE THAN 50% FULL OF SEDIMENT BUILDER NEEDS TO BE AWARE AND CLEAN OUT IF THE FLOW OF STORMWATER IS IMPEDED BY THIS ____________________________________________________________________________________________________________________ 8/1/2023 - PREVIOUS INSPECTION NOTES STILL NEED TO CLEAR SWALE SO WATER CAN FLOW THROUGH THE LOT TO OUTFALL OR PUT A TEMPORARY CULVERT SO WATER CAN FLOW NEED TO REMOVE THE PORTA JOHN OUT OF SWALE TRUSSES ARE MOVE AT THIS TIME ------------------------------------------------------------------------------------ 7/31/2023 - PREVIOUS INSPECTION NOTES ** 07/31/23 BUILDER NEEDS TO REMOVE YOUR TRUSSES FROM THE ROADWAY IMMEDIATELY YOU ARE CREATING A SAFETY HAZARD FOR PEDESTRIANS, BICYCLISTS, AND MOTORIST ** BUILDER NEEDS TO REMOVE TRUSSES, PORT-A-JOHN AND CONSTRUCTION DEBRIS FROM THE ROAD SIDE SWALE IMMEDIATELY YOU ARE CREATING A SAFETY HAZARD FOR PEDESTRIANS, BICYCLISTS, AND MOTORISTS ** HUURICANE SEASON IS UPON YOU NEED TO MAINTAIN THE ROAD SIDE SWALE ON A DAILY BASIS OR INSTALL A TEMPORARY CULVERT. ** SEE ATTACHED PHOTOS
LATH/BRICK/ WATER BARRIER 10/06/2023 APPROVED FWILLIS
INSULATION 10/04/2023 APPROVED FWILLIS
Note: Inspector Notes from Inspection 2420 9/29/23- Previous note...#5.......the rear bath metal outlet box.( Vanity Light) Ground wire has not been bonded to the outlet. WILL CHECK AT INSULATION. 9/27/2023 - PREVIOUS INSPECTION NOTES 1. 5' head test is not holding water 2. The electrical rise installed does not match the riser drawing on page A3 of the approved plans. Please have the engineer submit a revision to the building department showing the as built riser. 3. Install nail plates, Rear bath 14-2 wire top chord. Master shower water supply lines, top plate. Master sink 12-2 wire, top plate. Garage wall door, Switch 14-2 wire top plate. 4. Plumbing vent above the master bathroom area needs to slope downward towards the drain. 5. The rear ceiling metal outlet box and the rear bath metal outlet box. Ground wire has not been bonded to the outlet. 6. A tub set inspection needs to be added.
ALL ROUGH 09/29/2023 APPROVED - AS NOTED JSTEWART
Note: 9/29/23- Previous note...#5.......the rear bath metal outlet box.( Vanity Light) Ground wire has not been bonded to the outlet. WILL CHECK AT INSULATION. 9/27/2023 - PREVIOUS INSPECTION NOTES 1. 5' head test is not holding water 2. The electrical rise installed does not match the riser drawing on page A3 of the approved plans. Please have the engineer submit a revision to the building department showing the as built riser. 3. Install nail plates, Rear bath 14-2 wire top chord. Master shower water supply lines, top plate. Master sink 12-2 wire, top plate. Garage wall door, Switch 14-2 wire top plate. 4. Plumbing vent above the master bathroom area needs to slope downward towards the drain. 5. The rear ceiling metal outlet box and the rear bath metal outlet box. Ground wire has not been bonded to the outlet. 6. A tub set inspection needs to be added.
ALL ROUGH 09/27/2023 Disapproved - NO FEE JWALKER
Note: 1. 5' head test is not holding water 2. The electrical riser installed does not match the riser drawing on page A3 of the approved plans. Please have the engineer submit a revision to the building department showing the as built riser. 3. Install nail plates, Rear bath 14-2 wire top chord. Master shower water supply lines, top plate. Master sink 12-2 wire, top plate. Garage wall door, Switch 14-2 wire top plate. 4. Plumbing vent above the master bathroom area needs to slope downward towards the drain. 5. The rear ceiling metal outlet box and the rear bath metal outlet box. Ground wire has not been bonded to the outlet. 6. A tub set inspection needs to be added.
ROOF VALLEY & METAL 09/19/2023 APPROVED KSANDOE
Note: Inspector Notes from Inspection 2460 9/18/23- Please install anchors at garage door bucks per Plan, before next inspection.
ROOF SHEATHING / BRACES/TIES/DOWN CELL 09/18/2023 APPROVED - AS NOTED JSTEWART
Note: 9/18/23- Please install anchors at garage door bucks per Plan, before next inspection.
ELECTRIC TEMP POLE 09/07/2023 APPROVED LMILLER
ROOF VALLEY & METAL 08/29/2023 Disapproved - NO FEE JSTEWART
Note: 8/29/23- Roof sheathing/braces/ties/down cells needs aproval prior to Roof valley metal
WALL SHEATHING 08/29/2023 APPROVED JSTEWART
ROW - DRAINAGE 08/07/2023 APPROVED - AS NOTED EMADISON
Note: ** 08/07/23 IT IS THE BUILDERS RESPONSIBILITY TO MAINTAIN THE ROAD SIDE SWALE ON A DAILY BASIS ** TEMPORARY CULVERT IS MORE THAN 50% FULL OF SEDIMENT BUILDER NEEDS TO BE AWARE AND CLEAN OUT IF THE FLOW OF STORMWATER IS IMPEDED BY THIS ____________________________________________________________________________________________________________________ 8/1/2023 - PREVIOUS INSPECTION NOTES STILL NEED TO CLEAR SWALE SO WATER CAN FLOW THROUGH THE LOT TO OUTFALL OR PUT A TEMPORARY CULVERT SO WATER CAN FLOW NEED TO REMOVE THE PORTA JOHN OUT OF SWALE TRUSSES ARE MOVE AT THIS TIME ------------------------------------------------------------------------------------ 7/31/2023 - PREVIOUS INSPECTION NOTES ** 07/31/23 BUILDER NEEDS TO REMOVE YOUR TRUSSES FROM THE ROADWAY IMMEDIATELY YOU ARE CREATING A SAFETY HAZARD FOR PEDESTRIANS, BICYCLISTS, AND MOTORIST ** BUILDER NEEDS TO REMOVE TRUSSES, PORT-A-JOHN AND CONSTRUCTION DEBRIS FROM THE ROAD SIDE SWALE IMMEDIATELY YOU ARE CREATING A SAFETY HAZARD FOR PEDESTRIANS, BICYCLISTS, AND MOTORISTS ** HUURICANE SEASON IS UPON YOU NEED TO MAINTAIN THE ROAD SIDE SWALE ON A DAILY BASIS OR INSTALL A TEMPORARY CULVERT. ** SEE ATTACHED PHOTOS
ROW - DRAINAGE 08/01/2023 Disapproved -FEE REQUIRED PFLANAGAN
Note: STILL NEED TO CLEAR SWALE SO WATER CAN FLOW THROUGH THE LOT TO OUTFALL OR PUT A TEMPORARY CULVERT SO WATER CAN FLOW NEED TO REMOVE THE PORTA JOHN OUT OF SWALE TRUSSES ARE MOVE AT THIS TIME ------------------------------------------------------------------------------------ 7/31/2023 - PREVIOUS INSPECTION NOTES ** 07/31/23 BUILDER NEEDS TO REMOVE YOUR TRUSSES FROM THE ROADWAY IMMEDIATELY YOU ARE CREATING A SAFETY HAZARD FOR PEDESTRIANS, BICYCLISTS, AND MOTORIST ** BUILDER NEEDS TO REMOVE TRUSSES, PORT-A-JOHN AND CONSTRUCTION DEBRIS FROM THE ROAD SIDE SWALE IMMEDIATELY YOU ARE CREATING A SAFETY HAZARD FOR PEDESTRIANS, BICYCLISTS, AND MOTORISTS ** HUURICANE SEASON IS UPON YOU NEED TO MAINTAIN THE ROAD SIDE SWALE ON A DAILY BASIS OR INSTALL A TEMPORARY CULVERT. ** SEE ATTACHED PHOTOS
ROW - DRAINAGE 07/31/2023 Disapproved -FEE REQUIRED EMADISON
Note: ** 07/31/23 BUILDER NEEDS TO REMOVE YOUR TRUSSES FROM THE ROADWAY IMMEDIATELY YOU ARE CREATING A SAFETY HAZARD FOR PEDESTRIANS, BICYCLISTS, AND MOTORIST ** BUILDER NEEDS TO REMOVE TRUSSES, PORT-A-JOHN AND CONSTRUCTION DEBRIS FROM THE ROAD SIDE SWALE IMMEDIATELY YOU ARE CREATING A SAFETY HAZARD FOR PEDESTRIANS, BICYCLISTS, AND MOTORISTS ** HUURICANE SEASON IS UPON YOU NEED TO MAINTAIN THE ROAD SIDE SWALE ON A DAILY BASIS OR INSTALL A TEMPORARY CULVERT. ** SEE ATTACHED PHOTOS ** FOLLOW UP INSPECTION 08/01/23
TIE BEAM / LINTEL 07/14/2023 APPROVED JSTEWART
Note: Inspector Notes from Inspection 2250 6/28/23--Please have Address Posted onsite by next inspection.
FOUND SURVEY APPROVED (OFFICE) 07/11/2023 APPROVED TBAKER
MONOLITHIC SLAB 06/28/2023 APPROVED - AS NOTED JSTEWART
Note: 6/28/23--Please have Address Posted onsite by next inspection.
PLUMBING 1ST ROUGH UNDERGROUND 06/16/2023 APPROVED MGIBSON
GRAVITY SEWER TEST 06/16/2023 APPROVED MGIBSON
WATER METER INSTALLATION REQUEST 06/02/2023 APPROVED CSTONE

Review History

Department Status Date In Date Out
ELEC COMPLETE 10/03/2023 10/09/2023
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
BLD COMPLETE 09/28/2023 10/03/2023
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
ELEC HOLD 09/28/2023 10/03/2023
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Need to show wire size for 300 amp service. NEC 2017 310.15 (B) (16)
BLD COMPLETE 09/12/2023 09/14/2023
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
BLD COMPLETE 08/21/2023 08/22/2023
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
BADMIN INFORMATION 08/21/2023 08/21/2023
Note: Marked INFORMATION By: BARBIE BEMBRY - (386)986-3780 - BUILDINGDIVISION@PALMCOASTGOV.COM Please upload this under the truss document type (not supporting document)
BLD COMPLETE 08/21/2023 08/22/2023
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
BLD HOLD 08/16/2023 08/21/2023
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Need upload the rest of the truss packet and show wich truss is being repaired.
BLD COMPLETE 08/01/2023 08/01/2023
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
MECH COMPLETE 08/01/2023 08/01/2023
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
ENGIN1 COMPLETE 07/11/2023 07/11/2023
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON COMPLETE 07/11/2023 07/11/2023
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
BLD COMPLETE 06/02/2023 06/05/2023
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
MECH COMPLETE 06/02/2023 06/05/2023
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
MECH COMPLETE 05/15/2023 05/15/2023
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
ELEC COMPLETE 05/15/2023 05/16/2023
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
BLD COMPLETE 05/15/2023 05/16/2023
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ZON COMPLETE 05/15/2023 05/15/2023
Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM changes made for calcs not zoning
BLD COMPLETE 05/05/2023 05/06/2023
Note: Released By: JPI
CUSVC COMPLETE 05/05/2023 05/08/2023
Note: Released By: HALEIGH HAND - -
ELEC HOLD 05/05/2023 05/08/2023
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Need correct outlet spacing NEC 2017 210.52. Bed 4 behind door.
ENGIN1 COMPLETE 05/05/2023 05/05/2023
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
GAS CANCEL 05/05/2023 05/05/2023
LOCATE COMPLETE 05/05/2023 05/09/2023
Note: Released By: CANDACE STONE - (386)986-2539 - CSTONE@PALMCOASTGOV.COM
MECH HOLD 05/05/2023 05/05/2023
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Duct layout needs to be signed by AC contractor per 107.1 FBC Residential 2020 7th Edition
SW1 COMPLETE 05/05/2023 05/12/2023
Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM
ZON COMPLETE 05/05/2023 05/05/2023
Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM
BADMIN COMPLETE 05/05/2023 05/08/2023
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
SWALE COMPLETE 05/05/2023 06/22/2023
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
SW ENG - INSPECTION 20 ¤20.00 03/14/2024
SW ENG - INSPECTION 20 ¤20.00 03/14/2024
SW ENG - INSPECTION 20 ¤20.00 03/14/2024
SW ENG - INSPECTION 20 ¤20.00 09/13/2023
SW ENG - INSPECTION 20 ¤20.00 09/13/2023
SW ENG - INSPECTION 20 ¤20.00 09/13/2023
PLAN REVIEW - REVISION ¤32.50 09/13/2023
CONNECTION FEES ¤1,166.26 05/23/2023
FIRE IMPACT FEE ADMIN ¤12.62 05/23/2023
FIRE IMPACT FEE ADMIN (¤12.62) 05/23/2023
FC IMPACT FEE EMS ¤62.00 05/23/2023
IMPACT FEE FIRE ¤420.52 05/23/2023
FC IMPACT FEE LAW ENFORCEMENT ¤218.00 05/23/2023
FC IMPACT FEE LIBRARY ¤268.00 05/23/2023
IMPACT FEE PARKS ¤1,769.15 05/23/2023
IMPACT FEE SCHOOL ¤5,450.00 05/23/2023
IMPACT FEE TRANSPORTATION ¤1,812.00 05/23/2023
WATER -IRRIGATION INSPECTION ¤25.00 05/23/2023
PARKS IMPACT FEE ADMIN ¤53.07 05/23/2023
PARKS IMPACT FEE ADMIN (¤53.07) 05/23/2023
SURCHARGE FS 533.721 ¤4.41 05/23/2023
SURCHARGE - FS 468.631 ¤6.62 05/23/2023
SW ENG - FOUNDATION SURVEY ¤20.00 05/23/2023
WATER- TURN ON ¤25.00 05/23/2023
ADJUSTMENT 50% (¤705.12) 05/23/2023
ADMINISTRATIVE RESIDENTIAL ¤30.00 05/23/2023
INSPECTION - RESIDENTIAL ¤1,075.25 05/23/2023
PLAN REVIEW - RESIDENTIAL ¤304.98 05/23/2023
SW ENG INSPECTION 80 ¤80.00 05/23/2023
SW ENG PRE APRON ¤30.00 05/23/2023
SW ENG - REVIEW 20 ¤20.00 05/23/2023
SW ENG RES REVIEW 200 ¤200.00 05/23/2023
TRANS IMPACT FEE ADMIN ¤54.36 05/23/2023
TRANS IMPACT FEE ADMIN (¤54.36) 05/23/2023
SEWER CREDIT (¤1,147.00) 05/23/2023
SEWER INSPECTION ¤25.00 05/23/2023
SEWER CAPITAL FACILITY ¤5,344.82 05/23/2023
WATER CAPITAL FACILITY FEE ¤3,923.88 05/23/2023
SITE PLAN 30 ¤30.00 05/23/2023
Fees Total Due: ¤0.00 Total Paid: ¤20,611.27