I want to search for...

Permit #2023050667

Permit Details

Status: CANCEL

Parcel Id: 07-11-31-7016-00010-0040
CONDITIONED SPACE: 1626 sqft
GARAGE: 2053 sqft
Total Square Footage: 3679 sqft
Block: 00010
Subdivision: 2201 - SECTION 16-COUNTRY CLUB COVE
Job Phone: 904-347-7837
Location Address: 8 COLECHESTER LN
Type: BA - BUILDING ADDITION
NOC: NO DOCUMENTATION
Applicant name: ERIC PAUL PANNONE
Owner: TAYLOR NATHANIEL & KASEY MEDFORD HAWKINS JTWROS

Address

8 COLECHESTER LANE

PALM COAST, FL 32137

Lot: 0040
Contracted Stated Job Value: ¤175,000.00
Job Description: Garage addition with loft and bathroom
Type: CN

Contractor

CASTAWAY CONSTRUCTION LLC
Status Location Address State License Number Phone
INACTIVE

30 FERNON LANE

PALM COAST, FL 32137

CRC1332311 (Exp: 08/31/2026) 904-347-7837

Sub Contractors

JASON BIANCANIELLO
Status Location Address State License Number Phone
ACTIVE

2434 COUNTY RD 304

BUNNELL, FL 32110

EC13007497 (Exp: 08/31/2026) 386-597-3350
ANTONIO VINCENZO DAHM
Status Location Address State License Number Phone
ACTIVE

10 RYBAR LANE

PALM COAST, FL 32164

CFC1429951 (Exp: 08/31/2026) 386-237-5692
SHAWN R RAMNARINE SINGH
Status Location Address State License Number Phone
INACTIVE

4 SEASIDE CT

PALM COAST, FL 32164

CAC1818766 (Exp: 08/31/2026) 306-302-2179
OLEG BELINSKIY
Status Location Address State License Number Phone
ACTIVE

19 PINE CIRCLE DRIVE19

PALM COAST, FL 32167

CCC1325974 (Exp: 08/31/2026) 386-263-7906

Inspection History

Type Request Date Result Inspector
PLUMBING 1ST ROUGH UNDERGROUND
MONOLITHIC SLAB
ALL ROUGH
ROOF SHEATHING / BRACES/TIES/DOWN CELL
INSULATION
BLD - BUILDING FINAL
ROW - FINAL INSPECTION
U -UTILITY RESIDENTIAL FINAL

Review History

Department Status Date In Date Out
BLD HOLD 05/11/2023 05/18/2023
Note: Held By: PATRICK BUCKLEY - (386)986-3786 - PBUCKLEY@PALMCOASTGOV.COM Plan Sheet 1/6 1. Change Note B (second bullet) to read: Openings between a garage and bedroom are prohibited. R302.5.1. 2. Provide floor design live, dead and total loads and allowable deflection limits. R301.4, R301.5, Table R301.5, Table R301.7 3. Provide roof design live and dead loads and deflection limits. R301.6, Table R301, Table R301.7 4. Provide exterior deck design live and dead loads and allowable deflection limits. R301.4, R301.5, Table R301.5, Table R301.7. 5. Provide guard and guard in-fill component design loads. R301.5, Table R301.5. 6. Provide stair design loads, R301.5, Table R301.5, Table R301.5 and footnote C. 7. Provide handrail design loads, R301.5, Table R301.5. 8. Provide soil bearing design capacity. R401.2, R401.4 Table R401.4.1 Plan Sheet 2/6 1. Provide note indicating no opening in guard shall allow passage of a 4 inch sphere. R312.1.3 2. Provide soffit detail that complies with code. Soffit is shown to be 24 inches wide and requires additional construction details. Provide type of soffit panels and provide soffit construction details in accordance with panel type. R704.1 through R704.2.4 and Table R704.2.4. 3. Provide attic ventilation calculations and show attic vents, type and location. R806. Plan Sheet 3/6 1. Identify location of required living space / garage separation at wall between stairs and garage and wall between loft and garage. If doors are located in separation wall, show type of doors to be used in separation. R302.5, R302.6. 2. Identify type of under stair protection for enclosed space under stairs. R302.7. 3. Show exterior landing width and length at exterior door. R311.3. 4. Provide note indicating garage floor to be sloped to garage roll up doors. R309.2 Plan Sheet 4/6 1. Identify window in bedroom as emergency escape window. R310.2 2. Identify window in bathroom at tub/shower as tempered glass. R308.4.5 3. Add note on plans that new smoke alarms in addition (both of them) are to be interconnected to the home’s existing smoke alarms and that existing portions of the home are subject to inspection and testing to ensure smoke alarms are properly interconnected. R314.1 through R314.6. 4. Show carbon monoxide alarm outside bedroom but within 10 feet of bedroom. R315.1 through R315.1.3. 5. Add note on plans that carbon monoxide alarms re required in existing home outside of, and within 10 feet of each bedroom and that existing portions of the home are subject to inspection and testing of carbon monoxide alarms. R315.1 through R315.1.3 6. Show width of stairs. R311.7.1. 7. Show width and length of landings at top and bottom of stairs. R311.7.6 8. Provide complete stair section. Show stair headroom, show stair construction, material and fastening details including stair stringers (number and type), risers, treads. Show overall rise and run of stairs and stair tread and risers rise and run. Show stair bull-nose detail. Provide handrail detail including type, mounting height, clearances and height. R311.7 through R311.7.8.5. 9. Identify location of required house / garage separation at wall between stairs and garage and wall between loft and garage. If doors are located in separation wall, show type of doors to be used in separation. R302.5, R302.6. 10. Show location of attic access. R807. 11. Provide hard, non-absorbent materials on tub / shower enclosure walls to height of 72 inches above floor. Indicate type of finish materials. R307.1. Provide wall backer materials type. R702.3.7, R702.4 Table R702.4.2. Plan Sheet 5/6 1. Indicate that draft stop is required in trussed floor system. Indicate draft stop materials. R302.12. 2. Identify rim joist type / closure system for floor trusses. R301.2.1.1, R503.1, WFCM. Plan Sheet 6/6 1. Revise stair detail to match stairs shown on floor plans (straight run). Provide stair fastening details to floor at top and at bottom on concrete slab. Provide stair tread bull-nosing detail. Show headroom. R311.7 through R311.7.8.5. Truss Plans 1. Provide complete truss plans signed and sealed by a Florida licensed professional engineer for both the floor trusses and roof trusses. Truss plans to be reviewed and stamped “approved” by building addition engineer of record. This is not a request for the building addition engineer of record to sign and seal truss plans. R502.11 through R502.11.4 (floor trusses), R802.10 through R802.11 (roof trusses). Other plans 1. Provide roof framing plan in plan view. Include rake wall eave / lookout construction details. Include roof support beams at exterior deck, attachment details of beams to columns. FBC-Building 107.3.5, R301.2.1.1 R802.2, WFCM. 2. Provide construction details for rake wall eave overhang / projection. R301.2.1.1 R602.3, WFCM. How will it be flashed? Sheathing? Attachment to wall? Framing? 3. Provide floor framing plan in plan view for 2nd floor – floor framing. FBC-Building 107.3.5, R301.2.1.1, R503.1, WFCM. 4. Provide more details for exterior deck construction. Plan Sheet 3/6 indicates CMU columns and concrete lintels. What is deck constructed of? Is it intended to be a concrete deck? Wood framed? If wood framed, provide deck framing plan including ledger board materials, ledger board attachment and fastening details, at house, joist spans, lumber grade and species, on-center spacing, beams, beam spans, beam lumber materials, grade and species and fastening, rim-joist / closure details. FBC-Building 107.3.5, R301.2.1.1, R503.1, WFCM. R507.
ELEC HOLD 05/11/2023 05/12/2023
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Outlets in bathroom, outdoors, and in the kitchen need to be GFCI protected. NEC 2017 210.52 2. Smoke alarm outside of bedroom needs to a combo alarm. FRC 2020 314 & 315. All smoke alarms need to be interconnected with the rest of the house. 3.Need to show the size of the existing service and submit electric load calcs and prove the service can accommodate the new loads.
GAS CANCEL 05/11/2023 05/15/2023
MECH HOLD 05/11/2023 05/15/2023
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Provide duct layout signed by the AC contractor
PLUM COMPLETE 05/11/2023 05/18/2023
Note: Released By: PATRICK BUCKLEY - (386)986-3786 - PBUCKLEY@PALMCOASTGOV.COM
SW1 HOLD 05/11/2023 05/15/2023
Note: Held By: EDWARD MADISON - - EMADISON@PALMCOASTGOV.COM BUILDER NEEDS TO REVIEW STORM WATER CHECK LIST FOR ALL REQUIREMENTS NEEDED ON A PROPOSED SUBMITTED SITE PLAN
ZON HOLD 05/11/2023 05/16/2023
Note: Held By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM Site plan: place all proposed plans on the site plan. Give all setback Include all mechanical equipment, Drive way ,walkways, and materials need to be included. Floor plan: garage depth exceeds 30' max adjust plans accordingly. Please provide the sq footage calculations of proposed plans for each floor in the addition. Please note that the garage can not exceed by 50% of the living area. Elevation PLan: plate height exceeds the plate height of the exixting residence please adjust they must be the same height on the addition. Please fill out a Single family affidavit have it signed by all owners.
ELEC CANCEL
MECH CANCEL
SW1 CANCEL
ZON CANCEL
BLD CANCEL