I want to search for...
Permit #2023050911
Permit Details
Status: FINAL
| Parcel Id: 48-11-31-1710-00000-0040 |
| Total Square Footage: 1394 sqft |
| Block: 00000 |
| Subdivision: 2087 - ESTATES AT GRAND HAVEN PHASE II |
| Job Phone: 386-679-5224 |
| Location Address: 182 WILLOW OAK WAY |
| Type: PO - POOL |
| Issue Date: 06/07/2023 |
| NOC: RECORDED |
| Applicant name: DONALD SHON MYRICK |
| Owner: THE AINSWORTH FAMILY TRUST |
|
Address LOT 167 BUNNELL, FL 32110 |
|
Address 2261 S. OLD DIXIE HWY BUNNELL, FL 32110 |
| Lot: 0040 |
| Contracted Stated Job Value: ¤75,000.00 |
| Job Description: in ground pool |
| Type: CN |
Contractor
MYRICK POOLS
| Status | Location Address | State License Number | Phone |
| ACTIVE |
1457 N US 1 ORMOND BEACH, FL 32174 |
CPC052531 (Exp: 08/31/2026) | 386-334-9822 |
Sub Contractors
STEPHEN COURTEAUX
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
85 North Yonge Street Ormond Beach, FL 32174 |
EC13001748 (Exp: 08/31/2026) | (386) 672-4900 | 386-676-7472 |
DONALD SHON MYRICK
| Status | Location Address | State License Number | Phone |
| ACTIVE |
1457 N US 1 ORMOND BEACH, FL 32174 |
CPC052531 (Exp: 08/31/2026) | 386-334-9822 |
Inspection History
| Type | Request Date | Result | Inspector |
| POOL FINAL | 12/29/2023 | FINAL APPROVED | AGAETANO |
| U -UTILITY RESIDENTIAL FINAL | 12/14/2023 | FINAL APPROVED | LFITZGERALD |
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 12/13/2023 | APPROVED | TPOLACEK |
| Note: 12/13/23 **At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved | |||
| ROW - FINAL INSPECTION | 12/13/2023 | APPROVED | TPOLACEK |
| Note: 12/13/23 **At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved | |||
| ELECTRIC AND ALARM | 11/28/2023 | APPROVED | BTAYLOR |
| POOL DECK | 10/05/2023 | APPROVED | BTAYLOR |
| STEEL AND GROUND | 06/20/2023 | APPROVED | BTAYLOR |
Review History
| Department | Status | Date In | Date Out |
| PLFM | CANCEL | 12/07/2023 | 12/11/2023 |
| BADMIN | INFORMATION | 12/07/2023 | 12/07/2023 |
| Note: Marked INFORMATION By: BARBIE BEMBRY - (386)986-3780 - BUILDINGDIVISION@PALMCOASTGOV.COM The submittal has been sent for floodplain review. The survey cannot be sent for inspection due to an expired NOC. Please resubmit the final survey for stormwater review/inspectino when the NOC has been updated. | |||
| BLD | COMPLETE | 06/06/2023 | 06/06/2023 |
| Note: Released By: PATRICK BUCKLEY - (386)986-3786 - PBUCKLEY@PALMCOASTGOV.COM Upon re-examining the submitted site plan for both the new home and pool, the AE Flood elevation is 7 feet for this lot per Surveyor Note No. 6 on Sheet 2 of the Site Plan. Proposed final lot grades are all at 7 feet or above with the lowest elevation at the rear left corner of the lot near the drainage easement being 7.00 feet. Based on these elevations and the finished elevations at the pool area, none of the pool structure and pool equipment areas will be in the floodplain. Based on this, the previous Building Review Hold has been removed. | |||
| BLD | HOLD | 05/17/2023 | 05/24/2023 |
| Note: Held By: PATRICK BUCKLEY - (386)986-3786 - PBUCKLEY@PALMCOASTGOV.COM ALL COMMENTS BELOW PER THE 2020 FLORIDA BUILDING CODE-RESIDENTIAL 1. Provide pool deck elevation for proposed pool. 2. Structural systems supporting proposed pool to be designed, connected and anchored to resist flotation, collapse or permanent lateral movement due to structural loads and stresses from flooding equal to the design flood elevation. Provide engineering statement on engineered pool plans confirming design conforms to this section. For previously approved Pool Master Plans, provide engineer's statement signed and sealed by the engineer on separate letterhead referencing this site address and permit number. R322.1.2. 3. Pool equipment located in floodplain is permitted to be installed below the design flood elevation provided it is elevated to the extent practical and is anchored to prevent flotation and resist flood forces and is supplied by electrical branch circuits that have ground-fault circuit interrupter protection. Electrical wiring systems are permitted below the design flood elevation provided they conform to the provisions of the Electrical Code for wet locations. Add notes to pool plans indicating a.) pool equipment will be installed at the highest elevation possible; b.) that all pool equipment will be anchored in a manner to prevent flotation and to resist flood forces; c.) that pool electrical equipment will be provided with branch circuits that are ground-fault circuit interrupter protected and d.) that all electrical equipment to be installed as required for wet locations per the 2017 NEC. R322.1.6 Exception. | |||
| ELEC | COMPLETE | 05/17/2023 | 05/22/2023 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 05/17/2023 | 05/17/2023 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 05/17/2023 | 05/23/2023 |
| Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 05/17/2023 | 05/17/2023 |
| Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| ADJUSTMENT 50% | (¤127.50) | 06/07/2023 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 06/07/2023 |
| INSPECTION- POOL | ¤160.00 | 06/07/2023 |
| PLAN REVIEW - RESIDENTIAL | ¤65.00 | 06/07/2023 |
| SURCHARGE FS 533.721 | ¤2.00 | 06/07/2023 |
| SURCHARGE - FS 468.631 | ¤2.00 | 06/07/2023 |
| SW ENG INSPECTION 40 | ¤40.00 | 06/07/2023 |
| SW ENG - REVIEW 20 | ¤20.00 | 06/07/2023 |
| SITE PLAN 30 | ¤30.00 | 06/07/2023 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤221.50 |